Western Railway Tender

... More
Search for the latest Gujarat tenders online related to civil works, road & transport, pipelines and more easily here on BidAssist. Here you can get any and every tender that is posted on the eProcurement Gujarat website, minus the clutter. No need for a tender ID, as on BidAssist, you can view any Gujarat tender by merely typing Gujarat in the search box.

Western Railway - WR Tender

Works
Telecommunication Services
Ireps
Opening Date16 May 2025
Closing Date6 Jun 2025
Tender Amount₹ 7,53,35,413 
Notes
Download

AI Insights

Bid Capacity
... View More
Available Bid Capacity = [A x N x 2] – 0.33 x N x B Where, A = Maximum value of construction works executed and payment received in any one of the previous three financial years or the current financial year (up to date of inviting tender), N = Number of years prescribed for completion of work for which bids have been invited, B = Existing commitments and balance amount of ongoing works with the tenderer.
Technical Capacity
... View More
The required prior work experience for the bidder includes having completed or substantially completed similar works within the last 7 years. The value and percentage of similar works completed are as follows: - 60% value of single similar nature work - 40% value of two similar nature works - 30% value of three similar nature works The bidder must have successfully completed or substantially completed any of the following: (i) Three similar works each costing not less than 30% of the advertised value of each component of the tender, (ii) Two similar works each costing not less than 40% of the advertised value of each component of the tender, (iii) One similar work each costing not less than 60% of the advertised value of each component of the tender. For subcontractors, they must have successfully completed at least one work similar to the work proposed for subcontract, costing not less than 35% value of the work to be subletted, in the last 5 years. Note that for subletting of work costing up to Rs 50 lakh, no previous work experience of the subcontractor is required.

Costs

Summary

Supply, Installation, Testing, Commissioning Of Indoor And Outdoor Telecom Material Including Trenching, Laying, Jointing Etc Of Ofc & Six Quad Cable In Samakhiali- Gandhidham Section, In Connection With Samakhiali- Gandhidhamn Quadrupiling Work Of Ahmedabad Division, Western Railway

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Installation, wiring, testing , commissioning of Drop / Insert Mux with E1 interface cards connection to 48V bus bar & termination of VF/Data interface circuit to the crone MDF in already installed 42U EURO Rack. This includes termination of PVC cable at both ends, taking PVC Cable over 26 runway or on the wall. This also includes supply of PVC cable of conductor size 0.63 mm. (ii) Testing and commissioning of STM-4/D/I Mux Equipment installed vide item no. 1 & 2 above using NMS as per as per approved test protocol. The work includes submission of all technical documents, manuals. All miscellaneous items required for the final testing and commissioning for the system will be supplied by the contractor.

6

16660

99960

... More
Supply, Installation, Testing, and Commissioning of GPS-based double-faced platform Clock as per RDSO/ SPN/TC@47>47@2008 Revision 4.1 or latest along with required SMPS charger and battery Backup of at least 180 Mins, along with other accessories.

10

36457

364570

... More
Supply of Central Data Controller Unit conforming to system requirement as per RDSO Specification No.RDSO/ SPN/ TC/ 108/2019 Rev.0.0 with Amdt -1 or latest. The control console shall have main and standby CPU to work in standby mode, one Nos. of 1 KVA UPS with two independent batteries, two LCD monitor [19 inch], CCU Rack, KVM Switch, CDS [Layer 3 12 Port Switch of make CISCO, HP, Juniper,Brocade, Avaya, Extreme, Netgear,D-link] and other accessories, housed in a 31 standard size cabinet along with driving Software for integrated passenger information system as per RDSO Specification No.RDSO/ SPN/ TC/ 108 /2019 Ver 1.0 with Amdt -1 or latest. this includes supply and installation of SW for Announcement system with necessary interface and announcement recording [Hindi/English/ Region language fresh studio copy of voice files.] as per RDSO Specification No. RDSO/ SPN/ TC/108/ 2019 Rev.0.0 with Amdt -1 or latest. [the same to be interfaced with existing audio and video system installed at the station. The software should support all types of display /announcement by merely adding necessary hardware in future [single/ multiline arrival/ departure train information display boards, single sided/double sided,CGDB, AGDB,LCD/LED/Plasma TVs etc.]

1

365132

365132

... More
Blowing of OFC through HDPE duct & protective work (elicited in above item) already 4 provided. Where it is not feasible to blow OFC due to curves, road/track crossings, bridges or for any other reason, OFC shall be drawn /laid manually as per standard procedure. All the equipments and machinery required shall be arranged by the contractor at his own cost.

220

10473

2304060

... More
Supply of 2 x 48 Fiber 2x 48 SC Type Rack Mountable FDMS loaded with SC '0' DB & Adaptor SC SM pigtail 1.5 meters with all the accessories required for installation.

90

39491

3554190

... More
Placing of DWC/RCC pipes along with collars in trenches at places of track and road crossing platform cutting etc.

1200

26

31200

... More
Installation of 4 port -48 DC Router 2 LAN port & 4 x Mbps G-703 port as RDSO specification No. RDSO/SPN/TC/84/2008 or as per latest specification.

12

47842

574104

... More
Preparation of cable Route Plan of buried S & T Cables using Radio Detector 8200 GS or 23 Similar model GPS Model and DGPS for per Trench per Km. For existing cables as per the instruction of Engineer in-charge. Submission of Report in KMZ File format. Soft Copy Only. In Open Line Section. (Unit read as per Trench Km).

110

36996

4069560

... More
Supply of 2 MB programmable primary digital drop insert multiplex as per RDSO Specs. IRS-TC 68/2012 Amdt. 1 or latest with conference facility and other stipulations of tender documents fully wired for 30 channels complete with power supply card remote control supervision facility and all other accessories, installation materials, manuals etc. it should have facilities to accommodate data interface card in multiple drop mode and should be able to support card needed for video 15 conferencing and ISDN. It shall also support NMS operations from local/remote locations to be provided in the section and should be compatible as well as inter operable at card level of the equipment provided in the adjoining section. The above MUX should be equipped with following circuits with maximum E & M cards got approved before supply. i) 2 wire/4 wire E & M VF Circuits (Minimum 4 circuits/card) ii Subscribers loop circuits (Minimum 4 circuits/card) iii) Exchange loop circuits (Minimum 4 nos.).

6

151343

908058

... More
Installation Testing and commissioning of different types of speakers with hanging arrangements and clamps on cover shed/ poles as per directions of Field Engineer.

50

568

28400

... More
"Cable route survey & Preparation of as built proposed and later final cable route and other plans (for OFC as well as other telecom cables whose laying is covered in this schedule) taking into account the points mentioned in chapter II & other chapters of technical require ment on Auto CAD for entire sections. The cable route & other plans shall be prepared by contractor after joint 1 survey, got approved from engineer in charge, changes during course of execution shall be incorporated in the same. After completion of the work all completion documents of tracing papers along with six prints of cable route plan, jointing & splicing schedule, cable hut wiring diagram etc. in six sets for each station and section in folders shall be supplied by the contractor. Contractor shall also supply the Auto CAD documents on CD. All the required materials, accessories including tracings, papers etc, shall be contractor's own. Note:-Contractor have to submit schematic of 4*48 OFC, fiber allocation and layout plan before commencement of work. And Final Fiber allocation and layout plan, Fiber tapping chart have to submit before commissioning of work. Policy regarding this has been attached.(both Hard and Soft copies have to provide)."

110

1240

136400

... More
Supply of G.I. Pipes 100 mm dia medium grade engraved on pipe as per spec. no. IS 1239 of 1990 or 1992 or latest with sockets and fittings. (Surya, Jindal, Tata, or Asian make.)

1200

566

679200

... More
Cement concrete work for miscellaneous items in the ratio 1 : 3 : 6 . Item includes excavation, ramming, curing and plastering with cement & sand mixture (aggregate not exceeding 3.8 cm.) (Aggregate cement & sand to be supplied by the contractor).

60

2847

170820

... More
Laying and drawing of CAT-6, Power Cable, OFC in casing & capping /Rigid PVC conduit through wall/structure of platform shed/ underground through GI/DWC/HDPE PIPE.

2135

16

34160

... More
Supply of UTP CAT 6 Cable for Indoor networking use, make: Molex or D-Link or Systemax.

2135

21

44835

... More
Supply & Installation of Plastocrate pre-fabricated (RCC) OFC jointing pits size 1000 mm x 1000 mm x 800 mm (depth) . The material shall be supplied as per engineer in charge instructions.

100

4602

460200

... More
Supply of Universal Fare Display System with Power, Data Cable & Connectors for PRS/UTS/Thin Client as per given Technical Specifications.

6

3919

23514

... More
Installation of maintenance free earth electrode for maintenance free earth spec of RDSO/SPN/197/2008 or latest.

30

4819

144570

... More
Transportation and Laying of HDPE pipe as per approved cable route plan in the 3 excavated trench, taking due care while transporting and laying the same in the trenches or other protective works. Both the end of duct should be sealed with end plugs before laying and should remain sealed till blowing is done.

120

6994

839280

... More
Supply of 4/2 wire Emergency portable control telephone IRS TC: 03 TC-75/99 with amendment 1&2 or latest along with standard lengthh line cord and 6 pin plug as per RDSO Spec no. IRS TC 42/87 or latest

1

2449

2449

... More
Supply of 6 CORE FIBER Optic cable as per RDSO spec. No. IRS:TC:55/2006 (Rev-1) with Amend. No. 2 or latest.

3000

24

72000

... More
Installation testing and commissioning of Universal Fare Display System for PRS/UTS/Thin Client with all required accessories and configurations.

6

419

2514

... More
Supply of Patch Cord cable (10 m long with SC/APC/FC-PC/LC-FC/SCSC/LC-SC/LC-LC/ST- SC as per site requirement) as per RDSO/SPN /TC/69 /2007 rev 0 or at the latest.

150

398

59700

... More
Supply of Double Walled Corrugated (DWC) HDPE Pipe with associated collars etc. as per RDSO Specification No. RDSO/ SPN/204/2011 or latest anti-rodent & anti-oxidant and non flame propagating type in 6 meters straight length and of size 120 mm outer dia, & 103.5 mm inner dia. 2 (The manufacturers, suppliers must produce valid IS license and should be certified under ISO 9000 and shall submit copy of certificate). One of the following coupling arrangements should also be supplied with each pipe as per the site requirement. 1) Suitable snap fit coupler with rubber 'O-Ring 2) Spacers 3) Tees 4) Bend, 5) End-cap (The total quantity of above items is equal to no. of pipes supplied.) DWC pipe shall be marked at every 1 mtr length in such a way that manufacturer's name, vender name and year of manufacture can be easily identified.

200

1859

371800

... More
Supply of 20 Pair CT Box Wago Type made up of atleast 18 SWG galvanised MS sheet, 11 spray painted Gray Colour, locking arrangenment, Termination of 0.9mm U/G Quad cable, it includes supply of Hylum Sheet 12mm 52 thick, Nuts, Bolts, suitable size of GI Pipe for Fixing on the wall for U/G Quad Cable, with disconnection facility.

50

2351

117550

... More
Supply of 6-pin emergency plug & socket flat type as per RDSO spec no. IRS: TC-42-87 Amd. 3 or latest.

55

520

28600

... More
Supply of Fixed cellular telephone- GSM 2G/3G/4G LTE, Vo LTE support, WiFi function 17 with minimum battery capacity 1000mAh, suitable adaptor and surge protection. The FCT should be suitable for 4G VoLTE SIMs of JIO and 3G/4G of BSNL and other service providers. Make Beetel FWP F3-4G or Similar from Beetel or Motorola or Matrix only. Warranty minimum 1 year.

6

4656

27936

... More
Supply of Maintenance Free Earth Electrode of length 3m, including supply of 3 bags of Earth enhancement material for earthling (20KGs /bag) for each electrode & other accessories as per Drg. No. SDO/RDSO /E&B /001 and RDSO Spec No. RDSO/SPN/197/2008 or latest.

30

12990

389700

... More
Supply of paint & painting of telephone mark with indicating arrow, indicating the direction of the nearest emergency socket on the RCC route/joint markers & EC socket box with kmtrs. All paints used shall be of Asian/Shalimar/Acolyte make with ISI mark. The indicating Arrow and all other writing work shall be done using black enameled paint with background painted Yellow. The work shall be carried out as per direction of site engineer.

55

87

4785

... More
Fixing of 10/12/20 pairs CT box for termination cables as per the details approved by the engineer. All the required materials shall be supplied by the contractor.

50

319

15950

... More
Installation, testing and commissioning of Train information At A Glance display board with all accessories as per RDSO specification no. RDSO/ SPN/ TC/ 108/2019 Ver.1.0 with Amdt -1 or latest.

1

30407

30407

... More
Supply of Double Face Coach Guidance Display Board with all necessary accessories confirming to system requirement as per RDSO Specification No. RDSO/ SPN/ TC/ 108/2019 Ver.1.0 with Amdt -1 or latest

35

28280

989800

... More
Installation wiring commissioning of 48 volt / 50 Amp SMPS based charger along with the power supply wiring from Power room to equipment room in ladder, wire, SPD, MCB, ladder and any other material required for installation will be arranged by the contractor.

6

2775

16650

... More
Supply of Emergency Socket Box in FRP material as per RDSO Spec RDSO/SPN/TC/44/2002 Amd 3.0 or latest.

55

1724

94820

... More
Horizontal direction drilling/boring without damage of surface road using Auger Machine. The bore shall be minimum 150 mm dia & shall be done at the depth of minimum 1500 mm from the ground level. The ground level shall be considered ignoring the bank height of the bank of 15 the road. The length of the bore shall be minimum 4 Mtrs long. The HDD with or without HDPE pipe as per direction of Engineer In Charge. Note:- Contactor shall provide all material required for boring and adequate nos. of labours for proper laying of cables into the bore. Cable shall be laid cautiously so that it should not get damage due to rough handling & pressure on cable. This also includes transportation & pulling/pushing of 2 to 3 HDPE Duct through bore.

55000

543

29865000

... More
Painting of emergency socket assembly and rail post by applying one coat of red oxide as base color, and then painting the assembly as per zebra painting in white and black colors. The width of each of the black and white colors shall be 100mm. All paints used shall be with ISI mark.

55

559

30745

... More
Fixing & laying of 100 mm dia GI pipes and parapet wall/roof of culverts, including masonry work at both ends with contractors own material and bending of the pipe at the both ends etc. as per directive of Engineer in-charge, Perforation should be done before laying of GI pipes.

1200

156

187200

... More
Providing brick masonry in ratio 1:6 cement and mortar including plastering with 1:4 24 cement and sand mixture both sides, 20 mm thick each with contractor's owned class II bricks, including excavation, curing, grouting, bolting etc. wherever required. Bricks sand and cement to be supplied by the contractor.

30

2256

67680

... More
Supply of Straight Joint Enclosures (SJC) complete with all accessories as per Spec no. RDSO/SPN/TC/68/ 2025 Rev 2.0 or latest for 48 fiber, Raychem make model FOSC 400 B4 48F or RSICS make model 1500-L 183-XX or Birla VXL make model VT-200 or 3 M make model 2179 CS or TYCO make or better as per instruction and approval of Engineer In charge.

-

-

4

... More
Manual horizontal auger boring/drilling of 100mm dia Horizontal Bore across the 14 Railway Track/ Across Road at LC gates by Boring method at a depth of 1.65mm from the ground level/ ground level to be considered ignoring the bank height of the bank/road and insertion of HDPE/DWC/GI pipes etc., as per the instructions of Engineer in charge at site.

600

649

389400

... More
Supply of way station equipment with necessary mounting arrangement on composite 16 rack or on wall. It shall be (-) 48 Volt operated and shall have a provision to connect at least four station telephones and have a facility to give more connection. As per RDSO Spec. no. RDSO/SPN/TC/66/2007 or latest amd. 1 & 2.

12

57209

686508

... More
Cutting of the platform surface (Tile/Slab) for a depth of 25cm and a width of 10cms 49 and refilling/ Reconditioning/ Concerting /Repairing the platform after laying HDPE pipe and cable. Cutting should be done with marble cutting machine in proper manner and restore the same as before in such a manner that aesthetic of the platform is not disturbed.

600

211

126600

... More
Installation and wiring of SDH STM-4/ADMs primary drop insert multiplexers with all accessories, 19" rack with suitable stand/ platform made of MS angle/CC , power supply board FDF racks (Already installed) , DDF with miniature 'U' link type for 63E1s , runway ladder , etc. This includes connecting all pig tails, optical patch cords etc. to the SDH equipments. This also includes connecting the SDH and primary MUX equipment with all interface cards to the 48V Bus including supply of wires and connectors , termination of all E1 on DDF , taking PVC cable over runway or a wall and termination of VF interface circuits to the krone type. MDF at both the ends (Two Nos. 100 pair's 25 krones) Krone type DP (One No krone 100 pairs) for 30 circuits derived from Primary MUX to be supplied and provided. All other miscellaneous materials including switch board cable & PVC conduits from 19" rack up to way station equipments, stand for 19" rack , power supply board with 15/5 Amp. Plug & socket (2 Nos.) etc. should also be provided on this rack for testing and isolation of faults. Any other materials required to comply this item shall also be supplied by the contractor. This item also includes fixing krone MDF and termination of VF/DATA interface circuits inside the VF termination cabinet, wiring of U link panel inside the transformer bay. This also includes taking PVC cable on channels/ladders and terminating at both the ends. Required 50/100 pr. krone MDF shall be supplied by the contractor along with current and voltage protection arrangements for all the circuits.

6

17392

104352

... More
Supply of HDPE duct 40/33 mm as per RDSO/SPN/45/2013 Rev 2.0 and Amd.3 or latest with latest amendments . For each Km of HDPE duct following items are to be supplied:- (a) End Plugs- 2 Nos. (b) Cable sealing plugs -2 Nos. (c) Plastic couplers slip fit/push fit type - 2 Nos. (d) End plugs to 1 be provided along with drum -2 Nos. The color and nomenclature for short haul up side- Duct color- Green, Code printed -WRSU(at every meter) For Medium Haul- Dn Side-Duct color-Blue, code printed- WRMD(at every meter) For Long Haul - Up Side- Duct color-Orange, code printed-WRLU(at every meter), For Long Haul - Dn Side- Duct color-Grey, Code printed-WRLD(at every meter) Local Tail OFC Cable-Duct color-Yellow, Code printed-WRT(at every meter).

240

49739

11937360

... More
Fabrication of EC socket box, assembly and erection of fabricated assembly at the location indicated in the route chart and as per direction of Engineer in charge. This includes cutting of rails to required size, supply and welding of GI Pipe and base plate, fixing of EC Socket box, transportation of material to site, digging of pit and erection of whole assembly at site. The work also 17 includes the termination of 6 Quad/PIJF derivation cable on the strips of 6 pin EC socket inside emergency socket box. The fabrication of EC Socket box shall be done as per Drg. No. SK/CSTE/C/97/16 & SK/CSTE /C/97/20. Rail post will be supplied free of cost at the SSE (Tele) C/SBI depot in full lengths. Note - In addition to above, the centre pins of EC sockets shall be terminated with a dedicated pair of 6 Quad cable (Derivate through the tail PIJF cable) in the entire block section so as to provide magneto/auto telephone communication from each EC socket. (All materials supply by contractor except rails).

55

2962

162910

... More
Installation & Commissioning of double face coach guidance display boards/Speaker as supplied under schedule A, in open area. It includes Supply, hanging arrangement of coach indication board/speaker along with hood [Cover shed] in open space, [without shed feet's long [1:3:6] I area] 44 100 mm mm dia [OD] & 15 G.I. to be erected with concrete foundation of 3 Feet deep from platform level and on the pipe, an angle to be fixed on G.I. pipe as per site condition. Contractor to supply all required materials with G.I. pipe & G.I. sheet of 2 ft x3 ft which should be placed on the top of the board in open space as per approval of site engineer with angle fastening and crow guard. Supply of G.I. pipe included in this.

23

5492

126316

... More
Installation, testing, and commissioning of 5-line single-face indoor display boards as per RDSO/SPN/TC /108/ 2019 Ver.1 0 or the latest.

1

35582

35582

... More
Installation of fiber distribution management system rack mountable LIU (Supply 2 covered Above) with all installation materials, restoration wall etc. to original condition , splicing and termination of 2 x 48 fiber cable (With all contractor's materials), routing /dressing fibers as per directions of Engineer in-charge.

90

3637

327330

... More
Transportation and laying of 6 Quad/PIJF cables in Trenches/ GI pipe /RCC pipe/DWC 5 pipe, Trunking etc as per approved cable route Plan and instruction of Site Engineer. Empty cable drums to be retained by the contractor the cable drums with unused cable at site to be returned by the contractor from site to Stores of SSE/T/C/SBI.

55

6550

360250

... More
Installation and wiring and commissioning of maintenance free VRLA cells at each 31 station. Note:- The rate quoted shall be including the cost of DC bus bar of 48V DC /Power wire suitable stand etc., connection of power supply to the equipments. All the wiring shall be done with the suitable gauge of power wires through suitable casing / capping as per the instructions of railway engineer's. All the materials required for this item shall be supplied by the contractor.

6

2110

12660

... More
Supply of Train information At A Glance display board with all accessories as per RDSO specification no. RDSO/ SPN/ TC/ 108/2019 Ver.1.0 with Amdt -1 or latest.

1

191451

191451

... More
Installation, testing, fixing wiring and commissioning of PA system complete in all respect including material required for installation, testing, fixing and commissioning.

6

4150

24900

... More
Installation, testing and commissioning of CDC set as per RDSO Specification No. RDSO/ SPN/ TC/ 108/2019 Ver 1.0 with Amdt -1 or latest

1

10110

10110

... More
Supply of 19''- 24U Dustproof Cabinet along with Front Glass Door, Key locking at Front 27 and Rear Door, Horizontal/Vertical Shelf arrangement, Termination Panel & Fan Cooling arrangements as per instruction of Site Engineer for Housing of Various S&T equipment like PA System, Router, Switches, Modem, E1/LAN Extender, etc

6

33731

202386

... More
Supply & Installation of Power Supply Distribution Box along with MCB /Fuse as per specification and requirement given by Site Engineer, Make-3M, SNATEL, ABB, or .similar

6

18469

110814

... More
Supply of 5-line single-face indoor display boards with their mechanical structure and necessary software i.e conforming to system requirements along with all accessories as per RDSO Specification No. RDSO/SPN /TC/ 108/ 2019 Ver.1.0 or the latest.

1

309765

309765

... More
Supply of 4 port -48 DC Router 2 LAN port & 4 x Mbps G-703 port as RDSO specification No. RDSO/SPN/TC/84/2008 or as per latest specification.

12

191366

2296392

... More
Supply of Thermo shrinkable joint kit as per RDSO spec no. IRS TC 77/2012 Rev-3 or latest suitable for 2T joint RTSF3 suitable to 6-quad cable of spec no. IRS TC-30/2005, Ver-1, Amd-4 or latest.

60

2794

167640

... More
Installation, wiring, testing and commissioning of way side equipment and telephone on the rack as per consignee in charge.

12

2255

27060

... More
Supply of CLI push button telephones suitable for connection with way side equipment and the system mentioned above. as per DOT/TEC specifications TEC /GR/CP/Tele/-002/05 Jan-2010 with latest amendment IRS TC: 38/97 Amd.1 & from DOT/TEC approved firms.

20

676

13520

... More
Supply of Two Port E1 module which can be accommodated in the Managed media converter to convert E1 to ETH for SCADA purpose similar

4

23548

94192

... More
"Hiring of one non-AC pick up vehicle for Supervisors(up to 2000 Kms per month) Tata/Mahindra or similar type of vehicle including maintenance, major minor repairs, cost of lubrication, fuel, drivers and all other ancillary cost etc. complete"

12

39469

473628

... More
Supply of Microphone with chord and other accessories with Microphone stand confirming to RDSO/SPN/TC/63/2006 Rev 0.0 or latest.

6

2582

15492

... More
Supply of Waterproof PA Horn speaker 30 watts as per clause No 4.5 of RDSO Spec No. RDSO/SPN/TC/63/2006 Rev 0.0 or latest.

40

1446

57840

... More
Excavation of trench 300mm wide at the bottom and 1.2 mtr deep, in all type of soils including clearing of trees, bushes, etc. and refilling of cable trench by excavated soil and ramming after laying of HDPE DUCT (laying of HDPE/DWC & 6 Quad. cables , PDF cables etc., will be paid under 6 different items of the schedule). Where desired dimensions of trenches could not be achieved proportionate payment will be made as decided by Engineer-in-charge of the Railway at site.The trenching outside the station limits I.e.) between the home signal of station 'A' to home signal of station 'B' may be done manually or by machine, as per the directions of site in charge. In no case the payment will be made for the trench of higher dimensions, than the dimensions as mentioned above.

2000

239

478000

... More
Splicing of laid under above items OFC cable and making the splice joint in dust free environment with contractor's own equipments and labour. Straight joint enclosure (SJC) is covered under schedule 'A' remaining all required materials, tools , plants shall be arranged by the contractor. splicing shall be started from one end and each splicing shall be monitored after splicing and after closing the enclosure for all the fibers from one central location by contractor's engineer with his own OTDR and optic Talk set with railway engineer , trace for the fibers shall be taken and signed jointly, if any fibred splice shows high loss/lossy event, the same shall be redone before completion of splicing work. The splice loss shall be as per the policy/technical circulars issued by the railways from time to time.

-

-

8

... More
Supply of maintenance free VRLA secondary cells duly charged of 48V 200AH and each 19 2.0V when fully charged 200AH capacity along with accessories i.e. inter sell connectivity links/float, 4 Nos. Insulators for each cell 24 Nos. of cell per set as per RDSO Spcn. IRS/S /93/96A with latest amendments with cuticle steel/hylam tray battery rack to install /house batteries.

6

55584

333504

... More
Supply of 48V Managed media converter (Ethernet/E1 to Optical) as per RDSO spec No. RDSO/SPN/TC/103, Rev 2.0 or latest and as per details given below for SCADA working. Its includes three tributary slots & one optical module supporting distance of 20 Kms with (1+1) protection on optical interface (one dual core & one single core) , 2E1 ports and four 100Mbps ETH interface through Optical interface and built in DSL modem to work on quad or copper (2W) up to five kms with auto change over feature between DSL line (2W) & Optical interfaces and three tributary slots loaded with one four port E&M interface supporting 2W/4W configurable for TPC / EC provision ; one tributary slot loaded with ETH module supporting RSTP feature for connecting RTU and one tributary module support four port two wire voice for connecting hotline & Auto phone ( 2 port each (FXO & FXS ). Unit to be standard telecom rack mountable and supplied with rack mounting kit / Unit to have E1 tributary module supporting two E1 as option for converting E1 to ETH for RTU purpose at SSP/SP/TSS locations. Type of Media convertor- option3, Media convert or without POE, patch cord cable- not required, SFP- should support 20KMS distance.

-

-

29

... More
Installation, Testing & commissioning of OFC Equipment vide supply item no. 29 & 30 for SCADA per location between OFC room & SP/SSP /TSS and in Test room

4

14585

58340

... More
"End to end testing of all fiber of the optical fibred cable laid under above items 11 between station/cable huts. All required equipments, tools and plants shall be arranged by the contractor. Five nos. of print out of traces in folders of OFC parameters/ results, The per kilometer link loss shall be as per the policy /technical circulars issued by the railways from time to time. Note:- Contractor have to submit pre-laying and post-termination OTDR test record."

20

11886

237720

... More
Installation, Testing, and Commissioning of Double Faced Coach Guidance Display Boards in the Covered area with complete accessories as per RDSO/SPN/ TC/108/2019 Ver.1.0 or the latest

12

2867

34404

... More
Supply, Installation, Testing, and commissioning of Two zone Power Amplifier set of 240 Watt, 230V AC /24V DC confirming to RDSO/SPN /TC /63/2006 Rev 0.0 or latest amd. Ahuja or similar make complete with one set of Microphone, Cord, and Stand.

6

18461

110766

... More
Supply of Standard 19" Rackmountable, (-) 48V DC Working, AddDrop STM-4 SDH Equipment conforming to TEC GR No.GR/SDH/-010/03 JA 2011 (with the latest amendment) complete with redundant power supply, 2 Nos. STM 4 of Aggregate L 4.2 Optical interface Modules/ Cards, one each for East and West side TX/RX and 2 nos. of STM-1 S1.1 or L1.1 Optical interface modules complete with 5 mts. long Optical Patch Cords, 63 E1s cards with DDFs and Cable assembly for 14 termination to DDF, and minimum 8 nos. of 10/100 Base-T Ethernet Ports/Fast Ethernet on SDH (EoS) 10/100 Base-T interface Module/ Card supporting with LCAS and GFP, Order wire sub-rack, DDF installation Material, Manuals, and other accessories along with Complete Engineering Order Wire (EOW) arrangement. Note: (i) It should have the necessary software/Firmware for Local/remote Monitoring/ Configuration of the equipment through NMS. (ii) Two no MCBs of appropriate rating along with necessary connecting cords and cables for the Power Supply Module/Card should be supplied and installed as per instruction on the site in charge.

6

288113

1728678

... More
Supply of Twin Core shielded cable of size 24/36 SWG with a standard color (Red and Black) having screening coverage of 95 % area of the sheath of the cable using a braided copper conductor.

3000

32

96000

... More
Supply, Transportation & Installation of RCC cable route marker engraved and painted on both sides along the route every 50 mt. & route diversions as per site incharge instruction.

2200

339

745800

... More
Supply of one Quad VF 2T Transformer joint assemble of VF transformer 1120:470. As per IRS:TC 76/2021 ver 1.0 or latest.

55

1210

66550

... More
Installation & commissioning of Single line double faced Train Arrival/Departure Display board. This includes all required accessories required including hanging structure for fixing arrangements to commissioning the item.

-

-

46

... More
Installation, testing and commissioning of Platform Data Controller as per RDSO 42 specification no. RDSO/SPN/ TC/ 108/ 2019, Ver. 1.0, Amdt.- 1 or latest and as per instruction of Engineer in charge. All required material [except CDS/PDC] for fixing the CDS/ PDC are to be arranged by the contractor. Installation and commissioning of Platform Data Controller (PDC)as per instruction of site engineer.

4

2645

10580

... More
Supply of 19" covered racks, Vero President /Rittel make or similar having size of approximately 2.2 mtr. (42U) height x 600mm width x 600mm depth and duly approved by the 13 engineer in charge of the work. The rack shall be complete with all fittings for housing SDH equipment, primary Muxes, DDF, MDF using krone module and other equipment like runway ladders etc. completely wired and equipped with integrated protection modules for all channels. It should be possible to lock all the equipment with only order wire telephone remaining outside the rack.

8

34492

275936

... More
"Excavation of cable trench in rocky area, 450 mm wide at the top, 300 mm at the bottom and minimum 0.5 meter deep in rocky area (hard rocky soil mixed with boulders/hard murrum) including cleaning of trees, bushes. The trenching will be done manually only and limited to the stretch between the home signal to home signal of each station and other locations as per the directives of the site in charge. Where desired dimensions of trenches could not be not achieved proportionate payment will be made as decided by Engineer-in-charge of the Railway at site. In no 7 case the payment will be made for trench of higher dimensions than the dimensions as mentioned above. 1. If, in case, depth of 1.2 M could not be achieved and Engineer-in-charge approves the same and then only after his instructions, the following protection work will be done - a) Depth of trench more than 1 Mtr. does not require any protection work and the payment will be made on pro-rate bases (Volumetric) under this item, after laying of HDPE /DWC Pipes, 6 quad. cable, PDF cables in the trenches (Laying of HPDE/DWC, 6 Quad cable & PDF cable, will be paid under different items of the schedule) and refilling of cable trench by excavated soft, soil, murmur, boulders etc. and ramming over the refilled trench. Care should be taken while refilling the cable trench such that the murrum/boulders etc do not damage the cable."

1000

366

366000

... More
Supply of Platform Data Controller as per RDSO specification no. RDSO/SPN/ TC/ 108/ 2019, Ver. 1.0, Amdt.- 1 or latest and as per instruction of Engineer incharge.

4

39522

158088

... More
Execution of Straight/Derivation/EC Joint on Quad/PIJF Cables as per instruction by site engineer.

60

1037

62220

... More
Supply, Installation, testing, and commissioning of surge protection cum safety device (Class B + Class C) suitable for single phase for Telecom Equipment as per RDSO specification No. RDSO/SPN /TC/98 /2011, Rev. 0 with Amendment No.1 or latest.

6

15381

92286

... More
"Supply & Installation of Electronic LC gate telephone system in 1+6 configuration with 52 inbuilt voice recorder . It includes supply of 'surge protection and line connection unit /circuit' and centralised power supply system with battery as per RDSO Spec no. RDSO/SPN/ TC/51/2011 Revision 3.0 amendment 1.0 or latest"

19

71379

1356201

... More
Supply of 48 V, 50 amps battery charger for telecom use as per No. RDSO/SPN./TL/23 20 /1999 (ver. 4) or latest in N+1 configuration i.e. using (2+1) modules of 25 amps with automatic switching between the modules for two sets of 200 AH battery for charging with SMF VRLA. It shall be equipped with surge and lightening protection of class 'B' and' C' the configuration shall be decided as per site requirement.

6

61502

369012

... More
Supply of Single Line Double face Platform Display Boards with all accessories as per RDSO specification no RDSO Specification No. RDSO/SPN /TC/108/2019 Ver.1.0 or the latest.

3

218290

654870

... More
Supply of power cable 3 core, 2.5 sq mm,multi strand [36/0.3mm dia.] cable as per IS 694:1990 reaffirmed 1995 or latest suitable for Railway electrification area, shall be of reputed make like Havells, Delton, LAPP, Finolex, or superior.

4000

40

160000

... More
Installation of 42U rack with necessary ladder for cable way up to 10 Mrs ladder (cable way) size 200mm wide 4mm thick. All material for ladder given by contractor.

8

8220

65760



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.