Military Engineer Services Tender
View complete overview of Goa MES Tender
Costs
EMD
₹ 69,960Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2021_MES_488263_1Bid Award Id
ViewTender No
8377/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
(b) One light point controlled by two Nos two way switches.
4
-
-
(c) One bell/buzzer point controlled by one bell push.
10
-
-
(d) One 5 pin switch socket outlet 5 Amps on independent board controlled by one switch.
170
-
-
(e) One 5 pin switch socket outlet 5 Amps on same board controlled by one switch.
50
-
-
Material and labour for point wiring complete as specified with 1100 V grade 4 Sqmm two runs of single core PVC insulated unsheathed multistranded copper conductor cable FRLS grade, conforming to relevant IS drawn through and including PVC casing and caping (ISI Marked) with all accessories fixed on surfaces of wall, ceiling, including sunk pressed steel terminal boxes made out of 2 mm thick MS sheet concealed in walls with 3 mm thick laminated Hylem sheet top cover fixed with brass screws for housing switches, socket etc including 4 Sqmm one run of single core PVC insulated and unsheathed copper conductor cable FRLS grade as earth continuity wire connected to common earth and earth dolly including testing complete all as specified and directed by Engr-in-Charge for one 6 pin switch socket outlet 15 Amps on independent board controlled by one switch.
90
-
-
Supply and fix switch piano flush type single pole, one way 5 Amp.
630
-
-
Supply and fix switch piano flush type single pole, two way 5 Amp.
8
-
-
Supply and fix bell push, flush type, 5 Amps.
10
-
-
Supply and fix Switch socket combination 2 in 1, 3 pin, 5 Amp type universal
250
-
-
Supply and fix Switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type universal
140
-
-
Supply and fix Socket outlet 2 in 1, 3 pin, 5 Amp .
100
-
-
Supply and fix stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as reqd.
265
-
-
Supply & Fixing modular switch 1 way 6A, 1 module, 230 volts.
210
-
-
Supply & Fixing modular switch one way 16 Amps, 1 module, 230 volts.
20
-
-
Supply & Fixing modular bell push 6 Amps, 1 module, 230 volts.
4
-
-
Supply & Fixing modular socket 6 Amps-2/3 pin combined, 2 module.
60
-
-
Supply & Fixing modular socket 6A/16A-2/3 pin combined, 2 module.
20
-
-
Supply & Fixing modular Fan step regulator, 120W - 2 module
20
-
-
Supply & fixing modular metal flush box 1/2 module.
4
-
-
Supply & fixing modular metal flush box 3 module.
40
-
-
Supply & fixing modular metal flush box 4 module.
12
-
-
Supply & fixing modular metal flush box 6 module.
8
-
-
Supply & fixing modular metal flush box 8 module.
10
-
-
Supply & fixing modular metal flush box 12 module.
10
-
-
Supply & fixing modular metal flush box 16 module.
6
-
-
Supply & fixing modular metal flush box 18 module.
6
-
-
Supply & fixing modular white cover plate with frame, 1/2 module
4
-
-
Supply & fixing modular white cover plate with frame, 3 module
40
-
-
Supply & fixing modular white cover plate with frame, 4 module
12
-
-
Supply & fixing modular white cover plate with frame, 6 module
8
-
-
Supply & fixing modular white cover plate with frame, 8 module
10
-
-
Supply & fixing modular white cover plate with frame, 12 module
10
-
-
Supply & fixing modular white cover plate with frame, 16 module
6
-
-
Supply & fixing modular white cover plate with frame, 18 module
6
-
-
Supply and fix bell Ding Dong AC, 230 volts, single pole.
2
-
-
Supply and fix ceiling rose, surface bakelite, 65x50 mm, two to three terminals complete.
334
-
-
Taking down MCB/MCCB DB/cut out/main switch /metal plug and socket of any size and making surface good as to match the existing surface.
37
-
-
Supply and fix sheet metal enclosure (DB) for MCB's, 4 way, single pole and neutral, 240 volts, double door complete.Make : Legrand (Ekinox 3) or equivalent in C&S/Havells
3
-
-
Supply and fix sheet metal enclosure (DB) for MCB's, 8 way, single pole and neutral, 240 volts, double door complete.Make : Legrand (Ekinox 3) or equivalent in C&S/Havells
6
-
-
Supply and fix sheet metal enclosure (DB) for MCB's, 16 way, single pole and neutral, 240 volts, double door complete.Make : Legrand (Ekinox 3) or equivalent in C&S/Havells
3
-
-
Supply and fix sheet metal enclosure (DB) for MCBs, 4 way, triple pole and neutral, 415 Volts, double door complete.Make : Legrand (Ekinox 3) or equivalent in C&S/Havells
12
-
-
Supply and fix sheet metal enclosure (DB) for MCBs, 8 way, triple pole and neutral, 415 Volts, double door with 200 Amps rated bus bars with IP 54- IK 09 complete.Make : Legrand (Ekinox 3) or equivalent in C&S/Havells
2
-
-
Supply and fix sheet metal enclosure (DB) for MCCB (Suitable for 160 Amps), vertical type,4 way, triple pole and neutral, 415 volts, double door with 200 Amps rated bus bar with IP 54- IK 09 Make : Legrand (Ekinox 3) or equivalent in C&S/Havells Note MCCB will be measured and paid separately under respective item of schedule
4
-
-
Supply and fix sheet metal enclosure single pole and neutral with a two pin and earth plug and socket complete with and including one single pole MCB 20 Amps,C series 240 Volts complete.
3
-
-
Supply and fix sheet metal enclosure tripple pole and neutral with a three pin and earth plug and socket complete with and including one four pole MCB 32 Amps,C series 240 Volts complete.
2
-
-
Supply and fix sheet metal enclosure tripple pole and neutral with a three pin and earth plug and socket complete with and including one four pole MCB 63 Amps,C series 240 Volts complete.
2
-
-
Supply and fix MCB, single pole, 0.5 Amp to 4 Amp, 240 Volts, 'C' Curve 10KA. Make: Legrand /C&S/Schneider /Havells/L&T
10
-
-
Supply and fix MCB, single pole, 6 Amp to 32 Amp, 240 Volts, 'C' Curve 10KA. Make: Legrand /C&S/Schneider /Havells/L&T
10
-
-
Supply and fix MCB, single pole and neutral, 6-32 Amp, 240 Volts, 'C' Curve 10 KA. Make:Legrand /C&S/Schneider /Havells/L&T
10
-
-
Supply and fix MCB, single pole and neutral, 40-63 Amp, 240 Volts, 'C' Curve 10 KA. Make:Legrand /C&S/Schneider /Havells/L&T
10
-
-
Supply and fix MCB, Triple pole , 40 Amp, 415 Volts, 'C' series 10 KA. Make: Legrand /C&S/Schneider /Havells/L&T
10
-
-
Supply and fix MCB, Triple pole and neutral , 63 Amp, 415 Volts, 'C' series 10 KA. Make: Legrand /C&S/Schneider /Havells/L&T
20
-
-
Supply only MCCB 160A,4 pole ,breaking capacity 25 KA Make: Legrand /C&S/Schneider /Havells/L&T (note: MCCB should be suitable for VTPN)
4
-
-
Material and Labour for sub main wiring with single core 1100 V grade conforming to relevant IS, PVC insulated unsheathed cables two run of 4 Sq mm multi stranded copper conductor drawn through and including 25 mm wide non metallic PVC caping casing incl all accessories fixed on walls/roof/floors/ceiling etc with an earth wire of one run 4 sqmm copper wire earth continuity conductor connecting to existing main switch board \ Distribution Board and testing on completion etc including taking down old submain wiring of any type with conduit/cpaing casing and making good disturbed surfaces to match existing all as specified and directed.
Note : Three runs of 4 sqmm cable and one run of PVC Caping casing not less than 25mm width shall be measured as one run.
450
-
-
Material and Labour for sub main wiring with single core 1100 V grade conforming to relevant IS, PVC insulated unsheathed cables two run of 6 Sq mm multi stranded copper conductor drawn through and including 25/32mm mm wide non metallic PVC caping casing incl all accessories fixed on walls/roof/floors/ceiling etc with an earth wire of one run 6 sqmm copper wire earth continuity conductor connecting to existing main switch board \ Distribution Board and testing on completion etc including taking down old submain wiring of any type with conduit/cpaing casing and making good disturbed surfaces to match existing all as specified and directed.
Note : Three runs of 6 sqmm cable and one run of PVC Caping casing 25/32mm width shall be measured as one run.
200
-
-
Material and Labour for sub main wiring with single core 1100 V grade conforming to relevant IS, PVC insulated unsheathed cables two run of 10 Sq mm multi stranded copper conductor drawn through and including 32mm mm wide non metallic PVC caping casing incl all accessories fixed on walls/roof/floors/ceiling etc with an earth wire of one run 10 sqmm copper wire earth continuity conductor connecting to existing main switch board \ Distribution Board and testing on completion etc including taking down old submain wiring of any type with conduit/cpaing casing and making good disturbed surfaces to match existing all as specified and directed.
Note : Three runs of 10 sqmm cable and one run of PVC Caping casing 32mm width shall be measured as one run.
100
-
-
Material and Labour for sub main wiring (three phase) with single core 1100 V grade conforming to relevant IS, PVC insulated unsheathed cables four runs of 6 Sq mm multi stranded copper conductor drawn through and including 32mm mm wide non metallic PVC caping casing incl all accessories fixed on walls/roof/floors/ceiling etc with an earth wire of one run 6 sqmm copper wire earth continuity conductor connecting to existing main switch board \ Distribution Board and testing on completion etc including taking down old submain wiring of any type with conduit/cpaing casing and making good disturbed surfaces to match existing all as specified and directed.
Note : five runs of 6 sqmm cable and one run of PVC Caping casing 32mm width shall be measured as one run.
100
-
-
Material and Labour for sub main wiring (three phase) with single core 1100 V grade conforming to relevant IS, PVC insulated unsheathed cables four run of 10 Sq mm multi stranded copper conductor drawn through and including 32mm mm wide non metallic PVC caping casing incl all accessories fixed on walls/roof/floors/ceiling etc with an earth wire of one run 10 sqmm copper wire earth continuity conductor connecting to existing main switch board \ Distribution Board and testing on completion etc including taking down old submain wiring of any type with conduit/cpaing casing and making good disturbed surfaces to match existing all as specified and directed.
Note : five runs of 10 sqmm cable and one run of PVC Caping casing 32mm width shall be measured as one run.
225
-
-
Supply and fixing lamp holder, PVC/Polycarbonate type with black plate suitable for batten fittings etc complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size and testing complete all as directed by Engr-in-charge.
10
-
-
Supply and fixing Surface mounted round LED 18W downlight for soft diffused lighting complete with all accessories internally pre-wired and including connecting up with twin core cable with suitable size.Make :Bajaj/Havells/Wipro/Philips.
20
-
-
Supply and fixing Surface mounted square LED 15W downlight for soft diffused lighting complete with all accessories internally pre-wired and including connecting up with twin core cable with suitable size.Make : Bajaj/Havells/Wipro/Philips.
40
-
-
Supply & Fixing Recess mounting LED fittings 36 watts , suitable for 600 mm x 600 mm (2ftx2ft) modular/POP/Gypsum ceiling, luminaire with white powder coated CRCA housing with LEDs. seamless front frame with fat white high transmission acrylic cover 230V, complete in all respect & accessories internally prewired including connecting up with twin copper twisted flexible copper conductor cable with suitable size incl taking down old fitting of any type. Bajaj/Havells/Wipro/Philips.
8
-
-
Supply & Fixing Sleek round recessed mounting LED downlight of 15 Watts (Cut out dia size 170mm) with AL die-cast body, finish with drop down PC diffuser to deliver low glare illumination with optimized heat sink for efficient heat dissipation with driver complete in all respect & accessories internally prewired including connecting up with twin copper twisted flexible copper conductor cable with suitable size and taking down old fitting of any type. Bajaj/Havells/Wipro/Philips.
5
-
-
Supply & Fixing Sleek round recessed mounting LED downlight of 9/10 Watts (Cut out dia size 130mm) with AL die-cast body, finish with drop down PC diffuser to deliver low glare illumination with optimized heat sink for efficient heat dissipation with driver complete in all respect & accessories internally prewired including connecting up with twin copper twisted flexible copper conductor cable with suitable size and taking down old fitting of any type. Bajaj/Havells/Wipro/Philips.
5
-
-
Supply & Fixing Sleek round recessed mounting LED downlight of 6/7 Watts (Cut out dia size 100mm) with AL die-cast body, finish with drop down PC diffuser to deliver low glare illumination with optimized heat sink for efficient heat dissipation with driver complete in all respect & accessories internally prewired including connecting up with twin copper twisted flexible copper conductor cable with suitable size and taking down old fitting of any type. Bajaj/Havells/Wipro/Philips.
5
-
-
M&L for earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6 mm thick buried directly in ground vertically to a depth not less than 2.25m below ground level with top edge of the earth plate at a depth not less than 1.5m below ground level, connected to galvanised earth lead wire 4.00 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel and other end of earth wire connected to main switch board and protected by galvanised iron pipe light grade 15mm bore and water pipe 20 mm bore GI medium grade with funnel and wire mesh PCC chamber in cement concrete 1:3:6 type C-2 and RCC cover with handle all as specified and shown in elect plate No 3 of SSR Part-I of 2009 complete all as specified and directed. NOTE :-
(i) The concrete pit shall be PCC (1:3:6) type C-1, 40 mm thick pre cast cover slab of RCC (1:2:4) type B-1 using 20mm graded stone aggregate reinforced with 8mm TMT bars @ 10 cm C/C on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in electrical plate No 3 of MES SSR Part-I.
(ii) The unit rate includes the cost of GI pipe medium grade for protection of earth wire and 4mm dia earh lead wire upto 7.5 M.
4
-
-
Taking down and servicing of ceiling fan 1200/1400 mm sweep at site and removing of old grease from bearing of ceiling fan and re-filling new grease including replacement of worn out nut bolt/ washer, rubber real bush, canopy and reassembling the fan complete and hanging on its original/ new position as directed by Engr-in-charge.Note: MS nut bolts with spilt pin, Ball bearing and Gun metal bush will be paid and measured seperately.
325
-
-
Taking down and servicing / cleaning of exhaust fan 230 to 300mm sweep at site and removing of old grease from bearing of exhaust fan and re-filling new grease including replacement of worn out nut bolt, rubber real bush, gun metal ball bearing, capacitor, split pin etc and re-assembling the fan complete all as directed by Engr-in-Charge
35
-
-
Servicing / cleaning of Pedestal fan of any Size at site and removing of old grease from bearing of exhaust fan and re-filling new grease including replacement of worn out nut bolt, rubber real bush, gun metal ball bearing, capacitor, split pin etc and re-assembling the fan complete all as directed by Engr-in-Charge
20
-
-
Supply only MS Nut bolts with split pin as per sample and as directed by Engineer-in-Charge.
270
-
-
Supply only Ball bearing suitable size of ceiling fan / pedastal and exhaust-fan of any type and size
240
-
-
Supply only gun metal bush suitable for ceiling fan / pedastal and exhaust fan any type and size including removing old one.
300
-
-
Supply only Rubber bush & clamps for ceiling fan 1200/1400 mm all as existing make and model ceiling fan.
255
-
-
Taking down and opening the body cover of ceiling fan any type and make and cutting the existing worn out winding with out damaging the stator removing the coil insulation and putting new insulation of polyster paper, winding with super enameled copper wire of suitable gauge with correct number of turns of auxillary and main winding and varnishing and backing complete including soldering new lead of copper wire testing complete including transportation to work shop and back all as directed Note : -
(a) Contractor have to make the arrangement for testing of Rewinded fan upto 24hrs at Gomantak Sub stn and in case of failure to above said testing a penalty of Rs 200/- per fan is deducted from contractors due and rewinding of same once again is bonded. (b) Fan should be return to MES yard after rewinding within 10 days from the date of issue otherwise a penalty of RS 10/- per day per fan is deducted from contractor due.
-
-
-
(a) Ceiling fans 1200/1400 mm sweep
330
-
-
(b) Exhaust fan Upto 230 to 300mm sweep
35
-
-
(c) Wall mounted fan300/ 400mm sweep
20
-
-
Material & Labour for Preparation of old painted surface of ceiling fan/Wall fan and applying one coat of synthetic enamel paint with spraying paint on machine including making MES number on body of the fan including taking down, refixing, connecting and testing complete all as specified & directed by Engr-in- charge.
300
-
-
Supply & Fixing in repair fan capacitor 1 mfd 240 V AC supply.
60
-
-
Supply & Fixing in repair fan capacitor 2.5 mfd 240 V AC supply.
1000
-
-
Supply & Fixing in repair fan capacitor 4 mfd 240 V AC supply.
27
-
-
Supply & fixing brushless direct current (BLDC) ceiling fan 1200mm sweep (ISI Marked), 230 volts, 26 Watt includung connection rod as per existing size of length of GI pipe medium grade including dismantling of old one and depositing in MES store yard as per specified and directed by Engr-in-Charge. Make : Orient/Havells/Bajaj
35
-
-
Supply & fixing wall mount fan 400mm sweep (ISI marked) 230 volts including dismantling of old one depositing in MES store yard as per specified and directed by Engr-in-Charge. Make : Usha/Havells/Bajaj
15
-
-
Supply & fixing exhaust fan 230mm sweep (metal body), heavy duty, 230 volts including dismantling of old one depositing in MES store yard as per specified and directed by Engr-in-Charge. Make : Usha/Havells/Bajaj
15
-
-
Supply & fixing exhaust fan 300mm sweep(metal body), heavy duty, 230 volts including dismantling of old one depositing in MES store yard as per specified and directed by Engr-in-Charge. Make : Usha/Havells/Bajaj
22
-
-
Supply & fixing exhaust fan 200 mm sweep plastic body, 230 volts including dismantling of old one depositing in MES store yard as per specified and directed by Engr-in-Charge. Make : Usha/Havells/Bajaj
25
-
-
Supply & fixing exhaust fan 250 mm sweep plastic body, 230 volts including dismantling of old one depositing in MES store yard as per specified and directed by Engr-in-Charge. Make : Usha/Havells/Bajaj
25
-
-
Supply & fixing exhaust fan 300 mm sweep plastic body, 230 volts including dismantling of old one depositing in MES store yard as per specified and directed by Engr-in-Charge. Make : Usha/Havells/Bajaj
15
-
-
Taking down carefully storage type water heater (Geyser) of 25/50 litres capactity after disconnecting inlet/outlet/vent pipes, electric/earth connections etc cleaning of the body inlet/outlet/vent pipes stop cocks non return valves etc leakage arresting of inner copper/steel tank by welding/brazing etc reassembling the geyser by replacing gaskets worn out nuts washers etc refixing the same in position by replacing mounting bolts and nuts reconnecting all inlet/outlet/vent pipes electric/earth connections and carrying out testing for proper functioning all as directed by Engineer-in-Charge. Note : Parts will be measured and paid seperately.
20
-
-
Supply only heating element of 1.5 KW/2.0 KW capacity of storage type water heater of compatible type including making all connections by replacing inter connecting copper conductor cables and removal of old unserviceable elements all as directed by Engineer-in-Charge.
50
-
-
Supply only thermostat suitable for 25/50 litre capacity storage type water heater including removal of old unserviceable ones as directed by Engineer-in-Charge.
50
-
-
Supply only cut out for 25/50 litre capacity storage type water heater including removal of old unserviceable ones as directed by Engineer-in-Charge.
50
-
-
Supply only non return valve (gun metal) of size 16/20mm including removal of old ones all as specified and directed by Engr-in-Charge.
5
-
-
Supply and fix CPVC SDR 11 fittings union of size 16 mm dia bore including taking down old u/s GI union
10
-
-
Supply and fixing CPVC SDR 11 fittings union of size 20mm dia bore including taking down old u/s GI union
10
-
-
Supply and fixing of CPVC pipes 16mm bore SDR 11 and plain CPVC SDR 11 fitting on wall/ ceiling or laying on floors complete all as specified including taking out old GI pipe.
20
-
-
Supply and fixing of CPVC pipes 20mm bore SDR 11 and plain CPVC SDR 11 fitting on wall/ ceiling or laying on floors complete all as specified including taking out old GI pipe.
20
-
-
Supply & installed storage type water heater (Geyser) capacity 25 Ltrs(Vertical/horizontal) five star rating GMV type prefixing and grouting work for mounting nuts,bolts and washer etc in wall and reconnecting all inlet/outlet/vent pipees electrical/earthing connections and carrying out testing for proper functioning including dismantling of old geyser and deposited in MES store yard all as per directed and specified by Engr-in-charge. Make : Havells/Bajaj/Venus
4
-
-
Supply & installed Instantaneous type water heater (Geyser) capacity 03 Ltrs prefixing and grouting work for mounting nuts,bolts and washer etc in wall and reconnecting all inlet/outlet/vent pipees electrical/earthing connections and carrying out testing for proper functioning including dismantling of old geyser and deposited in MES store yard all as per directed and specified by Engr-in-charge. Make : Havells/Bajaj/Venus
4
-
-
Supply only flexible pipe connection suitable size with brass chromium plated coupling nut and PVC washers on both ends complete for cold/hot water inlet/outlet lines for geyser.
70
-
-
Supply only indicator lamp assembly complete for water heater (geyser) suitable to work on AC 230 V supply and to match the existing size any type including disconnecting and removal of old ones.
20
-
-
Preparation of old painted surface of 50 liters storage type water heater and applying two coats of white synthetic enamel paint of approved make as directed.
2
-
-
Preparation of old painted surface of 25 liters storage type water heater and applying two coats of white synthetic enamel paint of approved make as directed.
50
-
-
Supply only copper tank (inner) of 50 ltrs storage type water heater conforming to IS 2082-1978 suitable for vertical or horizontal type heaters including removal of old tanks of capacity.
2
-
-
Supply only copper tank (inner) of 25 ltrs storage type water heater conforming to IS 2082-1978 suitable for vertical or horizontal type heaters including removal of old tanks of capacity.
3
-
-
Supply and Fixing of flame proof 2X16/20 watt LED tube light fitting with IP65 protection complete with all accessories ,internally pre-wired including conecting up with suitable size three core FRLS copper conductor including taking down old fitting complete all as directed . Make: Crompton/Bajaj/Sudhir/Havells
4
-
-
Supply and Fixing of flame proof rotory switch in LM-6 enclosed in and including aluminium body enclosure with threaded cover with toggal action switch operated by a shrouded knob single pole, 10 Amps with double entries through way suitable for 20mm dia ERW threaded rigid steel conduit and 01 No MS plug of 20 mm including taking down of old fitting complete all as directed. dia . Make- SUDHIR Cat part No RI/A/146-3 (or) equivalent Make- BALIGA/FCG Power
4
-
-
Supply and fixing LED Panel driver suiatble for fitting of 15-18 Watts by taking out old unserviceable driver complete all as directed.
80
-
-
Supply and fixing LED Panel driver suiatble for fitting of 9-12 Watts by taking out old unserviceable driver complete all as directed.
40
-
-
Supply and fixing LED Panel driver suiatble for fitting of 36/40 Watts by taking out old unserviceable driver complete all as directed.
66
-
-
Supply and fixing Decorative, wall mounting, brushed nickle finish fixture with opal glass diffuser suitable for 4/7 W LED lamp E14 /E27 base including lamp complete all as directed.Make code of Havells(LHFOAIC1TZ1I040) or equivalent in Jaquar (JNL-NKL-WLBPGG001E27)/Wipro/Luker
12
-
-
Supply and fixing Decorative, wall mounting, chrome finish fixture with opal glass diffuser suitable for 4W(E14) / 7.5 W A60 LED lamp E27 base including lamp complete all as directed.Jaquar (JNL-CHR-MB160275211A)/Havells (LHFOAJD1TZ1C060) or equivalent in luker/Wipro
12
-
-
Suppy and fixing recessed & surface LED 1 ft x 4 ft Panel ceiling light 36/40W complete including taking down old fitting .Make Crompton(LCTLRNE-40-CDL(1X4)) or equivalent in Bajaj/C&S/Luker/Wipro
6
-
-
Evaluation Notes How It Works ?