Military Engineer Services Tender
If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.
Costs
EMD
₹ 1,00,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_682558_1Tender No
PD/EANWMM/04/24-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Supply and filling of Haudraulic Bollard oil as per existing make Neptune Faac complete all as specified
80
-
-
Supply and fixing in repair J275-600 Bollard Piston seal kit complete all as specified and as directed by Dy Project Director.
8
-
-
Supply and fixing in repair 624 BLD Control card for bollard complete all as specified and as directed by Dy Project Director.
3
-
-
Supply and fixing in repair 16 MFD Capacitor for bollard complete all as specified and as directed by Dy Project Director.
20
-
-
Supply and fixing in repair LED for bollard complete all as specified and as directed by Dy Project Director.
4
-
-
Supply and fixing in repair Cross for bollard complete all as specified and as directed by Dy Project Director.
3
-
-
Supply and fixing in repair J275-600 Bollard Pump (complete hydraulic unit) complete all as specified and as directed by Dy Project Director.
1
-
-
Supply and fixing in repair Limit switch kit for bollard complete all as specified and as directed by Dy Project Director.
4
-
-
Supply and fixing in repair Solenoid valve complete all as specified and as directed by Dy Project Director.
2
-
-
Visit of the Engineer/ Commissioning Enginner/BMS Expert for checking Under Vehicle Surveillance System and BMS,PA Eqpt and CCTV system for checking of software and hardware problems & surveying of the whole system and to generate the report of the visit. Report shall indicates if any major repair/repair needed along with the cost impact which will be catered separately as per direction of Dy Project Director.(Cost incl. only visit and report generation )
4
-
-
Supply, Installation, Testing and Commissioning Graphical Software providing the facility to create / provide the following, static and animate the Graphics, Navigation between pages, display of logs, changing the time zones; the BMS platform shall natively support standard communication protocols such as Lontalk and Modbus / BACnet and the software shall be Web Based Software required to remotely monitor the system for 5 concurrent users & shall have inbuilt email facility (without using any external software / hardware) to send critical alarms to users with and including all the components and accessories mentioned above and also complying with all the requirements mentioned here-in and in the Particular Specifications, complete all as specified and as directed by Dy Project Director.
Note for Sl. Item No. 14 here-in-before: - The unit rate quoted shall be deemed to include for the complete set of Graphical Software with all components and accessories as mentioned above comprising of all the items and complying with all the requirements and specifications as described above and in Particular Specifications and all as directed by Dy Project Director.
1
-
-
Supply, Installation, Testing and Commissioning in repair of necessary Hardwares, Gateway / Router / Converter / Softwares for Integrating it with the 3rd party Devices on Bacnet / Modbus / Lonworks complete all as specified and as directed by Dy Project Director.
1
-
-
Supply, Installing, Testing and Commissioning Immersion type pipe mounted water flow switch of paddle type wth NO/NC Contacts complete all as specified and as directed by Dy Project Director.
6
-
-
Supply, Installing, Testing and Commissioning Upper / Medium / Lower level switches for tanks with setting options at different levels as required and 3 NO/NC Contacts complete all as specified and as directed by Dy Project Director.
8
-
-
Supply, Installing, Testing and Commissioning Indoor display type wall mounted temperature cum humidity sensor, Room Temperature sensor shall be with 4-20 mA transmitters, the temperature measurement range shall be 0 deg C to 50 deg C, ± 0.2 deg C, room RH sensor shall be of range 0 to 95% non condensing, accuracy of RH sensor shall be ± 3% RH complete all as specified and as directed by Dy Project Director.
1
-
-
Supply, Installation, Testing and Commissioning in repair of PoE Managed Ethernet switch : 24 port RJ45 10 / 100 / 1000 Base T or 24 ports of fibre (MM) complete with SFP (Small formfactor pluggable) with 2 Uplink Fibre Ports complete with SFP, (shall be used for BMS System also), 24 port patch panels, fully loaded complete with patch cords and required hardware, wire managers, labelling and accessories complete all as specified and as directed by Dy Project Director.
Note - The unit rate quoted shall be deemed to include for all the components and accessories as mentioned above comprising of all the items and complying with all the requirements and specifications as described above and in Particular Specifications and all as directed by Dy Project Director.
2
-
-
Providing, Installing, Testing and Commissioning in repair of filed mounted Programmable and Application Specific Controllers of the following configurations, comprising of and including following components and accessories and complying with the following specifications all as directed by Dy Project Director: -
(a) The programmable controller processors shall be 32-Bit, 50 MH, LONchip BACnet Compatible.
(b) The DDC Controllers shall be on BACnet & UL listed. (c) The DDC controller shall be as per the I/O Summary. (d) Main DDC Controller shall have atleast 21 Input / Output points
(e) The above controllers shall be housed in a vandal proof, lockable and secure MS cabinets to be supplied alongwith the Controllers as per manufacturer design and specifications.The Control Panel shall be IP66 protection standard for mounting the DDCs, with Base Plate, Cable Truf, Glands for Cable Entry, transformer, relays, Fan, MCBs, Switches and other accessories with all other mounting accessories complete as required.
Note: - The unit rate quoted shall be deemed to include for the complete set with all components and accessories as mentioned above comprising of all the items and complying with all the requirements and specifications as described above and in Particular Specifications and all as directed by Dy Project Director.
2
-
-
Taking out of 42" Flat LED Color Monitor of make LG and carrying out to LG service centre for servicing/repair/ repair of unserviceable part & refixing the same after rectification of defect complete all as specified and as directed by Dy Project Director.
2
-
-
Supply, Installation, Testing and Commissioning Volume Controller for all the closed areas complete all as specified and as directed by Dy Project Director.
5
-
-
Supply, Installation, Testing and Commissioning in repair of 6W multitap voice alarm speaker, wall mountable BS 2839 Part 8, line voltage 100 V complete all as specified and as directed by Dy Project Director.
3
-
-
Supply, Installation, Testing and Commissioning in repair of 15W Outdoor Horn speakers, line voltage 100 V complete all as specified and as directed by Dy Project Director.
3
-
-
Taking down and repair of Day and Night bullet camera with IP66, IK10 rated vandal-resistant Varifocal 3-10 mm P-Iris lens, remote focus and zoom; Multiple, individually configurable H.264 and Motion JPEG streams; max HDTV 1080P resolution at 30 fps, WDR more than 70 dB, including mounting bracket for wall / ceiling / Pole or junction boxes and refixing the same after rectification the defect complete all as specified and as directed by Dy Project Director.
12
-
-
Taking down and repair of 360 degree Outdoor Dome IP Camera Panoramic with mini 5 Megapixel Sensor with 4 Megapixel resolution output with 10 FPS on full resolution, support SD card upto 128GB H.264 with high profile compression and refixing the same after rectification the defect complete all as specified and as directed by Dy Project Director.
11
-
-
Supplying, Laying and Testing in repair of Cat 6 UTP cable for CCTV and BMS System with all terminations crimping etc. complete all as specified and as directed by Dy Project Director.
915
-
-
Supplying, Laying and Testing in repair MM Optical Fibre cable of 6 core (Armoured) with all terminations, crimping etc. complete all as specified and as directed by Dy Project Director.
600
-
-
Supplying, Laying and Testing in repair Wiring for PA system using 1.5 sq. mm. size two core FRLS insulated copper conductor cable in existing surface / recessed conduit complete as required, all as specified and as directed by Dy Project Director.Make-Havells,Polycab
700
-
-
Supplying, Laying and Testing in repair PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cable (heavy duty) with stranded copper conductor of size 1.5 Sq. mm. 2 core 1100 Volts grade (for Signal, DDC communication, Third-party integration cable)
500
-
-
Supply and fixing in repair of Network Switch as per existing make and model complete all as specified and directed by Dy Project Director
2
-
-
Supply and fixing in repair Optical Fiber Patch Cord complete all as specified and directed.
10
-
-
Supply and fixing in repair CAT 6 Patch Cord complete all as specified and directed.
10
-
-
Supply and fixing in repair Camera Stand complete all as specified and directed.
5
-
-
Supply and fixing in repair Camera Mounting Pole complete all as specified and directed.
3
-
-
Supply, Installation, Testing and Commissioning in repair 32 channel NVR, Pre-installed, pre-configured IP storage solution with VMS license having 24 TB storage capacity, boosted by the High-end processor and 8 GB RAM, DSSRV2 NVR providing an optimal combination of processing installed, 2U rack mount, temperature +100C to +350C, relative humidity-8 to 90% (non-condensing), CE, UL Certified, the recording shall be calculated for all cameras for 30 days as required as per specifications & at site of work all as directed by Dy Project Director.
Note - The unit rate quoted shall be deemed to include for all the components and accessories as mentioned above comprising of all the items and complying with all the requirements and specifications as described above and in Particular Specifications and all as directed by Dy Project Director.
1
-
-
Repair of Under Vehicle Surveillance System having speed bump design, complete with hardware, with and including repair 4 Nos. of CCD / CMOS Area Scan cameras with IR bright white illumination LEDs integrated in a single module, chaceking of Automated Number plate reading system, digital video recorder with built in Multiplexer and UVSS Software, Multilingual Graphical user interface (GUI), Inductive loop sensor, IP-67 Standard etc. as required and also including fixing within the road complete all as specified and as directed by Dy Project Director. Note 1.Minor spares costing each up to Rs 500 shall be deemed included in the rate quoted above.
2. Any spares parts required to be replaced shall be measured and paid for separately under respective items.
2
-
-
Supply and fixing in repair Maintenace free bty for UPS 12V, 150Ah as per existing make and model-Exide FXP5-XP 1000 type complete all as specified and directed.
4
-
-
Rifilling of Existing Carbon Dioxide fire extinguisher capacity 4.5Kgs installed in various location at National War Memorial complete all as specified and as directed by Engr-in-Charge.
16
-
-
Supply and Fixing in repair of sealed lead acid battery 12V 42 Ah Make- Exide EP 42-12 type
30
-
-
Taking down cameras, lighting, UPS, POE switch for Anti Sabotage check and refixing the same after scanning & security checking complete
20
-
-
supplying & fixing 3000 VA microtek ups for 30 min back up complete including installation of batteries ( except cost of batteries which shall be measured separately ) all as per directions of engineer in charge at the specified location.
10
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%