Military Engineer Services Tender
BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.
Costs
EMD
₹ 5,12,500Document Cost
₹ 2,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_669857_1Bid Award Id
ViewTender No
84337/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Demolition of cement concrete(unreinforced) in ground floors and paving not exceeding 15 cm thickness (below or above ground level) and complete all as specified and as directed.
551
-
-
M & L 75 mm thick plain cement concrete M10(Nominal Mix) using 40 mm nominal size graded stone aggregates finished surface even and fair as in plinth protection all as specified and as directed.
6050
-
-
M & L for machine cut Kota stone slab flooring 18 to 20 mm thick over cement screed bed of 20 mm thick in cement mortar 1:3, laid and jointed with grey cement slurry, mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed.
6050
-
-
M & L for 18 to 20 mm thick machine cut Kota stone in risers of steps, skirting, dado and pillar laid on backing layer of 10 mm thick in cement mortar 1:3, laid and jointed, pointed with grey cement slurry, mixed with pigments to match the sheds including rubbing and polishing complete all as specified and directed.
250
-
-
Dismantling structural steel work including doors, gates but excluding framed truss etc into primary parts.
43.17
-
-
S & F hot rolled medium and high tensile structural steel (Fe-290 of grade 165 conforming to IS 2062: 2011) as in framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and as directed.
2208.08
-
-
S & F hot rolled medium and high tensile structural steel of grade E165 as per IS 15911: 2010 as in framed work such as grills, grating, etc., with ends of bars of shouldered and/or riveted, or forged into spikes, framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework water tanks and similar work complete all as specified and directed by Engineer-in-charge.
1808.64
-
-
S & F mild steel screw bolts (machine made), diameter of neck 11 to 15 mm with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exceeding 10 cm but not exceeding 15 cm long complete all as specified and as directed.
300
-
-
Dismantling of wall/ ceiling boards(fibre pulp insulation etc.) or insulations boards /slabs/blankets any thickness including cover fillets of any description including all snap grids and hanging arrangements complete all as specified.
1059.12
-
-
Taking down wooden chowkhats or frames with shutters (without taking off shutters from the frames) area exceeding 1.50 sqm but not exceeding 4.00 sqm each complete all as specified and as directed
160
-
-
Taking down wooden chowkhats or frames with shutters (without taking off shutters from the frames) area not exceeding 1.50 sqm each complete all as specified and as directed
152
-
-
S & F steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and as directed.
740
-
-
S & F steel ventilators with top hung shutters including hinges, steel peg stay complete all as specified and as directed.
43.2
-
-
Supply & fix sheet glass, ordinary quality, 4 mm thick and glazed with oil putty or fixed with beads in square not exceeding 0.5 Sqm in each pane complete all as specified and directed.
783.2
-
-
S & F 0.71mm thick plain aluminium sheeting, Alloy 31000 H4 ridges, hips, valley gutter, drip and straight flashing (length and girth as fixed) complete all as specified and as directed.
552.5
-
-
Dismantling of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc. complete all as specified and directed by Engineer in charge.
10
-
-
M & L for brick work with sub class 'B' bricks, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:6 complete all as specified and as directed.
10
-
-
Taking down cement plaster on stone/brick/concrete surfaces including racking out joint, hacking for key, scrubbing down with water complete all as specified and as directed.
1950
-
-
Material and labour for plastering 15 mm thick on fair faces of brick work or concrete surfaces (on vertical surfaces) in cement mortar 1:4 finished even and smooth without using extra cement mixing with WPC complete all as specified and as directed. Note- WPC shall be measured and paid separately.
1200
-
-
Material and labour for plastering 15 mm thick on fair faces of brick work or concrete surfaces (on vertical surfaces) in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and as directed.
800
-
-
Supply only liquid water proofing compound.
150
-
-
M & L for preparation of newly plastered surface of wall and applying two coats of cement based paint over one coat of alkali resistant primer complete all as specified and as directed
1200
-
-
Preparation of newly plastered surfaces on walls and applying three coats of white wash complete all as specified and as directed.
800
-
-
M & L for preparation of old/ newly plastered surfaces of wall and applying two coats of cement base paint over alkali resistant priming paint complete all as specified and as directed.
4500
-
-
Preparation of old decorated surfaces on walls and applying three coats of white wash complete all as specified and as directed.
4200
-
-
Preparation of old decorated surfaces on ceilings and applying three coats of white wash complete all as specified and as directed.
1000
-
-
Preparation of old painted steel surfaces of any description, over 10 cm width or girth and applying one coat of synthetic enamel paint and priming with red oxide primer complete all as specified and as directed.
2000
-
-
M & L for cement concrete M10 (Nominal Mix) using 40 mm nominal size graded crushed stone aggregate 75 mm thick in sub base for laying tiles, pavings, etc. complete all as specified and as directed.
1000
-
-
Demolition of reinforced cement concrete of any description (reinforcement cut as required to facilitate demolition) and in roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work complete all as specified and as directed.
10
-
-
M & L for RCC M15 (Nominal Mix) using 12.5 mm nominal size graded crushed stone aggregate as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed.
10
-
-
M & L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick (Horizontal or sloping) for rough finished flat surfaces of concrete complete all as specified and as directed.
250
-
-
M & L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips and including welding has to be done with minimum 20 cm over lap for new and old of any height complete all as specified and as directed.
400
-
-
M & L for mild steel TMT bars any dia in stirrups, spaces and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed
300
-
-
M & L for cement concrete M15 (Nominal Mix) using 12.5 mm nominal size coarse aggregate in copping of electric poles or roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and as directed.
4
-
-
S & F in repair 110 mm bore PVC (SWR) pipe single socketed in any length with rubber ring joints laid in trenches or in floor complete all as specified and directed by Engineer- in- charge.
180
-
-
S & F in repair PVC (SWR) bends any radius 110 mm dia conforming to IS 14735: 1999 complete all as specified and directed.
20
-
-
S & F in repair stack clamps for 110 mm bore pipe out of 50 mm by 5 mm flat iron and 16 mm dia round iron stay including bolts and nuts and securing ends of stays to wall or roof complete all as specified and directed.
40
-
-
M & L for hardcore (broken stone or boulders) of gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and as directed.
35
-
-
M & L for cement concrete M7.5 (Nominal Mix) using 40 mm nominal size graded crushed stone aggregate 75 mm thick in sub base for laying tiles, pavings, floorings etc. complete all as specified and as directed.
350
-
-
M & L for precast (Factory casted) cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate in kerb stone with plan or interlocking joints and setting in cement mortar (1:4) complete with joints to match complete all as specified and as directed.
12.38
-
-
Providing and laying 80 mm thick factory made cement concrete interlocking paver block of M40 grade conforming to IS 15658-2006 made by block making machine with strong vibratory compaction, of approved size, design & shape, cast in , with grey cement and pigment over and including 25 mm thick compacted bed of coarse sand complete all as per specification and as directed.
350
-
-
M & L for cement concrete in foundation, filling and mass concrete in M7.5(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
5.13
-
-
M& L for bird proofing net of 1 mm dia multi traded HDPE copolymer ultra violet resistant bird proofing netting with minimum 25mm X 25mm apreture of square or hexagonal shape complete all as per specification and as directed.
4100
-
-
S & F of stainless steel wind operated (SS 304) turbo roof ventillator of size 24 inch throat diameter and 2 mm thick and 1600 mm length gelcoated UV stabilized FRP base plate with surface tissue complete all as specified and as directed.
75
-
-
M & L for water proofing treatment on RCC roof etc. Comprising with the following operation and as specification :-
(a) Taking dwon exsiting old trafelt, bituminous compound, cement mortar including cleaning and removing debris to a distance exc 100 m n. exc 250m.
(b) M & L for 25mm thick PCC (1:2:4) cement concrete type B0 (12.5 mm graded aggregate)
(c) M & L for 15 mm thick screed with cement mortar (1:4) mixed with WPC over PCC when concrete is green.
(d) Preparing and cleaning of fully dried cement plastered surface.
(e) Applying one coat of cold bituminous primer to the plastered surface @ 0.25 liters per sqm conforming IS-3384.
(f) A layer of APP based polymeric membrane 3mm thick (minimum) weighing 3.5 kg per sqm reinforceed with polyster non woven fabric (weighing not less than 160 gms/sqm) shall be applied over bituminous primer as specified above. Application of polymeric membrane shall be by torch application, over lap shall be minimum 100 mm on tranverse direction and 75mm in longitudinal direction.
(g) One coat of aluminium paint over App membrane @ 0.11Kg/Sqm.
Note : Prior to execution of the APP membrane works, leak proof test shall be done by ponding of water on roof slab to minimum depth of 25 mm. The entre roof slab shall be flooded with water for 48 hours. The necessary barrier shall be made to make feasible to stagnate water for 48 hourse on roof slab.
750
-
-
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and as directed.
532
-
-
Taking down old unserviceable submain wiring 1.5 sqmm or 2.5 sqmm or 4 sqmm or 6 sqmm or 10 sqmm aluminium/copper conductors any number including batten/conduit/ casing capping/ concealed including removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surface to match the existing surface complete all as specified and as directed.
620
-
-
M & L for semi concealed point wiring for one light or one fan or one exhaust fan controlled by one switch complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the rate quoted by the bidder)
121
-
-
All as per Item No. 51 above but one 5 Amps 3/5 pin socket outlet on the same board with other switch complete all as per specification and directed.
2
-
-
All as per Item No. 51 above but one 5 Amps 3 pin switch socket combination on independent board complete all as per specification and directed.
12
-
-
All as per Item No. 51 above but wiring with cables of size 2.5 sqmm and cable of size 2.5 sqmm as continuous earth wire for one 15 Amps switch socket combination on independent board complete all as per specification and directed.
28
-
-
S & F switch, 6A, single pole, one way, 240 V, AC, 50 Hz, ordinary (IPXO), normal gap construction, unenclosed, flush type, screw type terminals, pattern no. 1, rocker type, design A complete all as specified and as directed.
123
-
-
S & F 3 pin socket outlets, 6A, 240 V, AC, 50 Hz with earthing contact, rewirable, pillar type terminal, normal protection, unenclosed, without Shutter, Flush type, Design B complete all as specified and as directed.
2
-
-
S & F switch socket combination with (3 pin and 2 pin) combined socket outlets, 6A, 240 V, AC, 50 Hz with earthing contact, rewirable, pillar type terminal, normal protection, unenclosed, without Shutter, Flush type, Design B and switch, 6 A, single pole, one way, 240 V, AC, 50 Hz, ordinary (IPXO), normal gap construction, unenclosed, flush type, screw type terminals, pattern no. 1, rocker type, design A complete all as specified and as directed.
12
-
-
S & F switch socket combination with (3 pin and 3 pin) having two earthing pins combined socket outlets, 6A & 16A, 240 V, AC, 50 Hz with earthing contact, rewirable, pillar type terminal, normal protection, unenclosed, without Shutter, Flush type, Design B and switch, 16 A, single pole, one way, 240 V, AC, 50 Hz, ordinary (IPXO), normal gap construction, unenclosed, flush type, screw type terminals, pattern no. 1, rocker type, design A and indicator and fuse complete all as specified and as directed.
12
-
-
S & F sheet metal enclosure with socket plug top and MCB single pole and neutral enclosure with two pin & earth plug and socket complete with MCB SP 20 Amps 240 volts complete all as specified and as directed.
16
-
-
S & F ceiling roses, 6A, 240 V, surface type, intended to support mechanical loads by means of flexible cord, having provision for the connection of switch wiring, screw type terminal, made out of Polyamide or hornbean complete all as specified and as directed.
121
-
-
M & L for semi concealed sub main wiring complete with and including two Nos single core PVC insulated, unsheathed flexible conductor FR-LSH cables 6 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through and including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories and fixed on walls and 6 sqmm one No single core copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable for earthing and connected to common earth dolly complete all as specified and directed by Engineer-in-charge. Note - PVC conduits/casing-caping and two runs of 6 sqmm cable, one run of 6 sqmm cable as earth shall be measured and paid as one unit length.
120
-
-
S & F double door MCB Distribution board of sheet metal enclosure, single pole and neutral, 8 way with 200 Amps rated bus bar, 240 volt, IP42 protection grade and fixed with PVC plug and screws and grouted in wall with M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
4
-
-
S & F double door MCB Distribution board of sheet metal enclosure, triple pole and neutral, 4 way with 200 Amps rated bus bar, 415 volt, IP42 protection grade and fixed with MS hold fast and grouted in wall with M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
2
-
-
S & F circuit breakers (MCB), single pole (SP), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage single phase, rated frequency 50 Hz, Rated current 6A to 32 A, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed.
28
-
-
S & F RCCB 4 modules 30 mA sensitivity 40 Amps capacity complete all as per specification and as directed.
4
-
-
S & F RCCB 4 modules 30 mA sensitivity 63 Amps capacity complete all as per specification and as directed.
2
-
-
S & F new 18/20 watt surface and wall mounted LED batten with polycarbonate housing and integrated driver complete all as specified and as directed (Make : Havells Cat No. LUMILINEBS18WLED865SPCWH or equivalent make)
48
-
-
S & F 80 watt LED energy saving new generation Highbay lighting luminaire has efficiency upto 125Im/W with opal diffuser including lamp including connecting up with twin core twisted flexible copper conductor cable with suitable size and having ingress proction of IP 66 with additional safety chain complete allas directed. (Make Crompton cat part No LHB11-80-CDL60HPM or its equivalent make of Havells/Bajaj/Phillips)
56
-
-
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or water supply pipes lines etc or not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in soft/ loose soil complete all as specified and as directed.
170
-
-
M & L for laying of bricks locally available sub class 'B' bricks (old size) for cable protection cover laid flat and dry in trenches over the cable perpendicular to the direction of cable all as directed.
4220
-
-
Supply & spreading in trenches sand cushioning to underground cable in trenches including spreading, levelling hand punning down complete all as specified and directed Note:- Depth of sand cushioning will be measured after punning down and levelling the sand properly.
43
-
-
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/ loose/ hard/ dense soil complete all as specified and as directed.
47.1
-
-
Removing excavated material (soils) not exceeding 50 m and depositing where directed at a level n exc. 1.5 m above the starting point
130.7
-
-
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 3 core with reduced neutral conductors (3½ core), nominal cross sectional area of main conductor 35 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed.
660
-
-
Cutting chases in brick walls to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., exceeding 10 cm but not exceeding 20 cm girth and making good the same with cement concrete M15 (Nominal Mix) using 12.5 mm nominal size coarse aggregate or cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 complete all as specified and as directed.
1500
-
-
Supplying & fixing to walls and ceilings or laid in floors 50 mm nominal bore, light grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
72
-
-
M & L for semi concealed point wiring for one light or one fan or one exhaust fan controlled by one switch complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including suitable dia stove enamelled ERW MS conduit ISI marked and conduit accessories fixed on wall/ceilling/floor etc for flameproof application including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed.
369
-
-
S&F Flameproof cum weatherproof Rotary type with termination box in LM6 16A single pole 250V complete all as specified and directed.
369
-
-
Supply and fix semi concealed sub main wiring complete with and including two Nos single core PVC insulated, unsheathed flexible conductor FR-LSH cables 6 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through and including medium protection stove enamelling rigid steel conduit as per IS 9537 (Part-II): 1981 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories and fixed on walls and 6 sqmm one No single core copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable for earthing and connected to common earth dolly complete all as specified and directed by Engineer-in-charge. Note - Three runs of 6 sqmm cable and one run of MS conduit shall be measured and paid as one unit length. Cost of cutting chase and making good shall be included in the quoted rate.
500
-
-
S & F for flameproof weatherproof encloser for MCB DB/186 08 way SPN iincluding gas cut O ring endless Neoprene rubber gas ket IP 66 as per IS 2147/1962 ISI marked made out of cast aluminium alloy LM-6, epoxy painted CMRI certified including 32 Amps SPN AC supply 230 volts one incoming and 06 Nos out going 6-32A SP including taking down old unserviceable DB complete all as per specification and directed.
18
-
-
S&F for Flameproof weatherproof encloser for MCB DB/186 04 Way TPN including gas cut O ring endless Neoprene rubber gas ket IP 66 as per IS 2147/1962 ISI marked made out of cast aluminium alloy LM-6 epoxy painted CMRI certified, including 01 NO MCB 4P 63 Amps - 01 No AC supply 420 volts 12 Nos outgoing MCB 1P 6-32A including taking downold unserviceable DB complete all as per spicified and directed.
9
-
-
S & F Flame proof LED tube light Fittings suitable for two LED rod of 18 watt including two Nos. LED rod complete all as directed. (Make crompton Cat Part No for batten EXTN2LT8- 16/20-VE and for rod cat No. LGT8-20-865-2 or equivalent make as given in Appx B)
144
-
-
S &F LED 60 watt Flameproof Higbay wellglass in dia cast Aluminium housing with heat resistant toughened glass including all each fixing arrangment complete all as specified and as directed. (Make Crompton Cat No FWL 1318-60-CDL-M or equivalent make as per make list)
162
-
-
S & F 35 Watt LED building security Light Fitting new generation energe saving and environmentatal frindly long life LED Street light made of pressure die cast aluminium housing with hight power LED as lightinh source and lence imbeded PC cover having TOP opening separate driver compartment with IP 65 protection and inpact resistance of IK07 complete all as specified and as directed.
80
-
-
S & F street light bracket fabicated out of GI Tubing light grade 32 mm bore bend to the shape as directed and of length 1.2 mtr complete with mounting MS clamp of flat iron size 40x5mm of suitable length 02 pairs including nut bolts etc of suitable size, including taking down complete all as per specification and directed.
80
-
-
M & L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 4.0 mm dia galvanised mild steel wire by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 20 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed by the Engineer-in-charge.
22
-
-
S & F earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4 mm dia galvanised mild steel wire complete all as specified and as directed.
80
-
-
Supply and fix Air termination (vertical conductor), single pointed copper rod 12 mm dia and 300 mm long including suitable design of fixing complete all as per specification and directed.
18
-
-
M & L for steel tubular swaged pole type 410 SP-77 (16.00 metre long) including CI base plate and painting with two coats of aluminium paint over a coat of red oxide zinc chrome primer on exposed portion as per direction of Engr- in-Charge complete as per directed.
18
-
-
Excavating in trenches not exceeding 1.5 m wide and exceeding 1.5 m but not exceeding 3.0 in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or not exceeding 10 sqm on plan and exceeding 1.5 m but not exceeding 3 m in depth and getting out in soft/ loose soil complete all as specified and as directed.
8.1
-
-
M & L for cement concrete in foundation, sub base of floor filling and mass concrete in M10(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
13.47
-
-
M & L for cement concrete M10 (Nominal Mix) using 20 mm nominal size coarse aggregate in pole coping or roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and as directed.
0.38
-
-
Supply and fixing 32 mm X 6 mm galvanised mild steel strip for horizontal conductors and down conductors including suitable design of fixing components of galvanised steel as per fig 28 of IS 2309: 1989 complete all as specified and as directed.
18
-
-
Test point terminal box of size 200x100x100 mm made out of 2 mm thick hot dip galvanised sheet drilled and screwed including 6 Nos 15mm long hexagonal head screws complete with test point terminal block made out of Gun metal or Phosphorus Bronze size 75x75x25 mm drilled and screwed including 3 Nos 8 mm dia 25mm long hexagonal head screws, etc complete all as specified and directed.
18
-
-
M & L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 32 mm X 6 mm galvanised mild steel strip by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 40 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed by the Engineer-in-charge.
36
-
-
Supplying & fixing to walls and ceilings or laid in floors 50 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
20
-
-
S& F 50 Sqmm Heat resistant Flam retardant HRFR PVC Insulated Industrial Cable Single Core HRFR PVC Insulated Industrial Grade Conductor (Unsheathed) Flexible Cable, 1100 Volts conforming to IS 694 including PVC conduit of 25 mm dia complete all as per specified and directed.
216
-
-
Evaluation Notes How It Works ?