Military Engineer Services Tender
BidAssist is a very user-friendly website that helps us to explore all the new opportunities so as to achieve growth in our business. It helps us to attain all the information with respect to any e-tender the Arunachal Pradesh government has posted on its website in a very hassle-free manner.
Military Engineer Services - MES Tender
Eprocure
Opening Date20 Jul 2024
Closing Date13 Sep 2024
Tender Amount₹ 28,80,000
Costs
EMD
₹ 57,600Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_666950_1Bid Award Id
ViewTender No
8839/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://https://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
REPAIR AND MAINT OF MISC E/M SERVICE AND OTHER ALLIED WORKS AT MTN BDE, FD HOSP, NURANANG, FD WKSP, ASC COY T/ CAMP, B DET OF AGE E/M UNDER GE 859 EWS
BOQ Items
Excavation in trenches, n exc 1.5m wide and m exc 1.5m in depth, for foundation, etc or for shafts, wells, cess-pits, menholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5m in depth and getting out for soft & loose soil.
80
-
-
Returning, filling in, including spreading, levelling, waterring and wall ramming in layers not exc 25 cm. for hard/dense soil.
70
-
-
Removing excavated material n exc. 50 m and depositing where directed at a layers not exc 25 cm. for hard/dense soil.
10
-
-
S&F High density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 laid in trenches of size 50 mm
340
-
-
M&L for earthing complete with galvanised steel earth plate electrode 60cmX60cmX6mm thick, burried directly in ground (earth pit not less than 2.25 metres deep below ground level)with top edge of the plate not less than 1.5 metres below normal groundlevel, connected to galvanised earth lead strip 32x6mm by means of volts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No-5 of SSR Part-I connected to earthing test point all as specified or indicated including excavation and connected earth work in hard/dense soil, PCC 1:3:6 type C-1 as in pit, 20mm dia GI pipe medium grade for watering pipe, 15 mm bore GI medium grade earth lead protection pipe, 50 mm thick RCC 1:2:4 type B-1 cover slab of earth pit reinforced with 8 mm dia TMT bars @ 10 cm C/C both ways and with handle made out of 10 mm dia bars, funnel, strainer,charcoal and testing on completion all as specified and directed..
5
-
-
M&L in replacement GI pipe light grade with all fittings complete grouted in ground all as specified for the 40 mm bore of pipe laid in trenches/fixed with poles/laid in road/plinth/floor for protection of cable complete all as specified.
9
-
-
M&L in replacement GI pipe light grade with all fittings complete grouted in ground all as specified for the 50 mm bore of pipe laid in trenches/fixed with poles/laid in road/plinth/floor for protection of cable complete all as specified.
9
-
-
Supply and fix in repair LT Over over head line phase seperator of any size (2 way) in between distribution span of LT over head lines all as directed by Engr-in-charge
25
-
-
Supply and fix cable jointing kit for 11 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for Outdoor type 10 to 16 sqmm 3.5/4 Core
6
-
-
All as per item No 12 here-in-before but 25 to 50 sqmm 3.5/ 4 Core
7
-
-
M&L for locating of electrical fault in UG cable of any size and repair by using of suitable size of cable lugs and straight through joint and make the good disturbed surfaces all as specified and directed by Engr-in-charge.
Note :- Cable joint kit,Earth work & Aluminium lugs will be measured and paid seperately in respective items.
14
-
-
Supply and fix in repair bracket for street light fitting made out of 32 mm dia light grade GI tubing bent to required shape 1.5m long including necessary GI clamps, nuts bolts and washers and fixing to the pole complete including taking down old or Old U/S bracket from the pole as directed.
19
-
-
Supply and fix in repair weather proof PVC junction box approved by CPRI street light control box made out of not less than 2mm thick of size 200mm x 140 mm x 95mm (approx) complete with hinged door locking arrangement and consisting of 2 Nos of suitable size cable glands consisting of 01 No panel mounted connector 4 pole MCB 6A 10KA 01No, including connecting up with the electrical connections and fixing and clamping complete and all as directed
19
-
-
Taking down unserviceable street light LED fitting/Flood light of any wattage and type from the pole/building of any height including disconnecting the cable connections for repairing of light fittings and refixing in same position all as specified and directed. Note : 1. Spares shall be measured and paid seperatly under relevent items.
2. The cost of replacing of internal connections, screws bolts etc shall deemed to be included in the repair cost.
90
-
-
Supply only Electronic Driver for street light/Flood light fitting 25 to 50 Watts
35
-
-
Supply and fix Electronic Driver for street light fitting/Flood light fitting 60 to 100 watts
35
-
-
Supply only LED plate for street light/Flood light fitting 25 to 50 Watts
23
-
-
Supply and fix LED plate for street light fitting/Flood light fitting 60 to 100 watts
23
-
-
Repairs to LED Garden/Post top lantern/path light fitting of any wattage and type on existing Wall / pole of any height and making serviceable condition all as directed.Note : 1. Spares shall be measured and paid seperatly under relevent items.2. The cost of replacing of internal connections, screws bolts etc shall deemed to be included in the repair cost.
30
-
-
Supply only Electronic Driver for Garden/Post top lantern/Path light fitting 5 to 15 Watts
15
-
-
Supply only Electronic Driver for Garden/Post top lantern/Path light fitting 20 to 45 Watts
13
-
-
Supply only LED plate for Garden/Post top lantern/Path light fitting 5 to 15 Watts
13
-
-
Supply only LED plate for Garden/Post top lantern/Path light fitting 20 to 45 Watts
13
-
-
M&L for Wiring for circuit/submain wiring 2 x 1.5 sq mm alongwith earth wire 1.5 sqmm with the of FRLS is PVC insulated copper conductor, single core cable in from junction box to street/flood light fitting on pole of any height as required all as specified and directed by engr in charge. Note:-Two run of cable copper conductor and non metallic PVC Rigid/ flexiable conduit(20mm dia) shall be measured as one unit length.
60
-
-
Supply and fixing in repair LED post top lantern fitting 40 watts on existing pipe of any size and height with all accessories prewired fixed with FI clamps nuts bolts etc. including taking down existing fittings all as directed (Make :Havells Cat part No RUBYPT40WLED757PSYMTOPC or CG Cat part No LPTO-40-CDL or equivalent Wipro/bajaj
8
-
-
Supply and fixing in repair LED garden light 8 watt Pressure die cast powder coated housing with PC diffuser.Efficient high output LED with IP65 protection as existing fitting on existing pipe of any size and height with all accessories prewired fixed with FI clamps nuts bolts etc. including taking down existing fittings all as directed (Make :Havells Cat Part No -BAMBOOBLS8WLED830PSYMTOPC or equivelant in CG/Wipro/bajaj
8
-
-
Supply and fix in Repair LED flood light fitting 70 W integral type light fixture, cast aluminum body, reflector, drivers, LEDs and accessories with system wattage 70 W.including taking down old and unserviceable. Make :Havells Cat No: JETAALBAFLOODLIGHT70W or equivalent in Philips/CG
4
-
-
All as per item No 30 here -in-brfore but LED flood light 100 Watt.including taking down old and unserviceable. Make : Cat No: JETAALBAFLOODLIGHT100W of Havells or equivalent in Philips/CG
3
-
-
Supply and fix in repair of LED street light 45 Watt fitting,environmental friendly long life, made up of pressure die cast aluminium housing with mid power LED as lighting source and PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07.
Make : Cat Part No TRP-409-45-57-SL-NS-GL-NSG of CG or equivalent in Philips/CG/Havells
47
-
-
All as per item no.32 here-in-before but of capacity 60 watts.
Make : TRP-409-60-57-SL-GL-NSG of CG or equivalent in Havells/Philips
51
-
-
All as per item no.32 here-in-before but of capacity 70 watts.
Make : TRP-409-70-57-SL-GL-NSG of CG or equivalent in Havells/Philips
41
-
-
M&L cutting the road hard standing & making good surface with PCC 1:3:6 C-1 Type Using 20 mm graded stone aggregate & removing the to distance n.exe 50mtr all as specified.
1.5
-
-
Supply and fix in repair street light Time switches Digital 24 hour, 440 V 2 pole 32 Amps including taking down the old u/s one complete all as specified and as directed.Make: Havells cat part No DHTQB01016 or equivelant in Legrand/L&T
3
-
-
S & F in repair of SMF sealed battery of 12 volts 26 AH capacity for the UPS all as specified and directed.
26
-
-
All as per item No 37 here-in-before but 12 Volt 75 Ah
2
-
-
M&L for repair/servicing of UPS of capacity upto 5 KVA by checking all electrical connection and rewiring the same and refix the same location or directed by Engr in charge including testing,commissioning and warranty of one year after date if repearing.
Note:- (i) PCB kit,SMPS and By pass switch etc will be measured and paid sepeartaly .
(ii) Minor parts e.g nut bolt screw wirng etc are included in quoted rate.
10
-
-
M&L for PCB kit of UPS up to capacity of 5 KVA
6
-
-
M&L for bypass switch of UPS up to capacity of 5 KVA
5
-
-
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including4mm suspension wire, one twin core cable flat or circular of size 10 sqmm
300
-
-
All as per item No 42 here-in-before but of size 6 sqmm
297
-
-
Over hauling and repair to Electronic Chemical Dosing Pump Granual based chloronome plants by cleaning the FRP Tank, and cleaning of filters and NRV , checking the delivery pipe line for chocking and cleaning the chlorination plant and maintainig properly including checking the level of oil in the gauge and topping up as and when required, checking the grands and maintain the plant in all respect and replacement of minor spare for smooth functioning of Chlorination Plant all as directed by Engineer in charge.
Note:- The unit rate quoted shall be deemed to include for the cost of replacement of minor spares for routine day to day maintenance and necessary servicing to keep the plants in running condition on all days including Sundays and holidays, Replacement of other major spares shall be measured and paid for separately.
6
-
-
Supply only the spares for smooth functioning of Chlorination plant Teflon gland square type 3 mm
10
-
-
Supply only the spares for smooth functioning of Chlorination plant Rubber ring for mixing chamber
4
-
-
Supply only the spares for smooth functioning of Chlorination plant PVC diaphram valve 25 mm dia heavy duty
4
-
-
Supply only the spares for smooth functioning of Chlorination plant PVC NRV set with glass ball for suction and delivery adopter 20 mm dia
2
-
-
Supply only the spares for smooth functioning of Chlorination plant Chloroscope kit / PH Kit upto 2ppm
4
-
-
M&L for repair & overhauling of monoblock pump set, taking out impeller, cleaning, descaling & greasing to bearings incl replacement of unserviceable parts such as bearings DE & NDE, gland flange, etc. Cleaning and varnishing the starter and rotar, winding, heating and drying replacement of burnt terminals of motor assembling in the pump with new packing materials nuts, bolts, washers checking alignment connecting all electrical/water connections,checking the vibrations& alignment, RPM,DOR , testing the pump set on full load all as directed by Engineer-in-Charge for the pumpsets of 5.0 HP Capacity Note :- (i) cost of small U/S parts such as new packing materials, nuts, bolts & washers , gland bolt & packing, coupling bushes , coupling bolts are is deemed to be included in quoted rates (ii) major unserviceable spares will be measured and paid separately as supply only.
2
-
-
All as per item No 50 Above but 1 to 3 HP capacity
2
-
-
Supply only Bearings DE & NDE for 5 to 7.5 HP monoblock pump set
2
-
-
Supply only Bearings DE & NDE for 100 HP centrifugal pump set
1
-
-
Supply only Bearings DE & NDE for 15 HP centrifugal pump set
1
-
-
M&L for replacing of Single phase preventer for motor in the existing panel board with new one at water supply installations and taking down old unserviceable items :-
2
-
-
M&L for rewinding of squirrel cage induction electrical motor , 3 phase, 415 volts with suitable size of copper enameled winding wire and insulating materials incl disconnecting all electrical connections ,decoupling from pump,taking down the motor from foundation , cleaning and varnishing the stator & rotor winding, heating and drying, replacement of burnt terminals, greasing to bearings, re-assembling the motor and refixing of motor on the foundation by using new nut, bolts and washers, coupling with pump,checking alignment connecting all electrical connections,checking the vibrations, RPM, DOR and testing on full load all as directed and specified for the 5.0 HP Capacity
2
-
-
All as per item No 56 above but 100 HP capacity
1
-
-
All as per item No 56 above but 15 HP capacity
1
-
-
Supplying and laying of CPVC pipes 20 mm SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified
10
-
-
All as per item No 59 Above but 25 mm dia
10
-
-
M&L for repair & overhauling of squirrel cage induction electrical motor , 3 phase, 415 volts incl disconnecting all electrical connections ,decoupling from pump,taking down the motor from foundation , cleaning and varnishing the stator & rotor winding, heating and drying, replacement of burnt terminals, greasing to bearings, re-assembling the motor and refixing of motor on the foundation by using new nut, bolts and washers, coupling with pump,checking alignment connecting all electrical connections,checking the vibrations, RPM, DOR and testing on full load all as directed and specified for the 100 HP Capacity
1
-
-
All as per item No 59 Above but 15 HP capacity
1
-
-
M&L for repair & overhauling of centrifugal pump set of any make, dismantling and taking down pump after disconnecting water supply connections,decoupling from motor removing out impeller, cleaning, descaling , greasing to bearings incl replacement of unserviceable parts such as bearingsDE & NDE, pump shaft sleeves, coupling pully, pump shaft etc. Assembly in the pump with new packing materials, nuts, bolts& washers , gland bolt & packing,coupling bushes ,coupling bolts and coupling with motor checking for vibration & alignment connecting delivery and suction pipe, testing the pump set all as directed by Engineer-in-Charge for the pump set of capacity 100 HP
1
-
-
All as per item No 63 above but 15 HP capacity
1
-
-
S&F gland packing or required size of gland of superior quality to centrifugal / monoblock pumps of capacity 100 HP
3
-
-
All as per item No 65 above but 15 HP
3
-
-
M&L for replacement of U/S leather packing sutiable for foot valve ,suction pipe flanged and pump including replacement of U/S nuts and bolts all as specified and directed
5
-
-
M&L for replacement of 3 Pole power contractor AC 415 V 180 Amps , AC3, Type suitable for 100 HP pump set
1
-
-
M&L for replacement of 3 Pole power contractor AC 415 V 45 Amps , AC3, Type suitable for 15 HP
1
-
-
M&L for carrying out 'B' check comprising replacement of fuel filters,oil filters,air filter element,changing lubricating oil,cleaning of fuel lines,checking leakges if any repair the leakge ,replacement of exhaust fan,gasket etc complete all as spoecified and directed for DG set 62.5 KVA complete all as specified and directed.
2
-
-
All as per item No 70 here-in-before but DG Set capacity 125 KVA
2
-
-
All as per item No 70 here-in-before but DG Set capacity 625 KVA
2
-
-
All as per item No 70 here-in-before but DG Set capacity 10 KVA
2
-
-
S&F in repair AVR with functions to adjust generator output voltage ,prevent voltage hunting,set under frequency,roll of knee point,set generator drop to 5% at full load,match AVR input to necessary output,set the over excitation cut off level ,set initial frequency ,related voltage dip,over voltage protection cut off level,max short circuit current with sensing input voltage range 170 - 250 V AC max,50-60 Hz frequency with out put max up to 120 V DC,countinious current 2.7 A & transient 6 A for 10 second including necessary control wiring complete from alternator to AVR complete testing & commissioning for DG set of capacity 62.5 KVA all as specified and directed by Engr in charge
1
-
-
All as per item No 74 here-in-before but DG Set capacity 125 KVA
1
-
-
All as per item No 74 here-in-before but DG Set capacity 625 KVA
1
-
-
S&F in repair the unserviceable V belt of DG set capacity 125 KVA
1
-
-
S&F in repair the unserviceable V belt of DG set capacity 625 KVA
1
-
-
S&F in repair the unserviceable V belt of DG set capacity 62.5 KVA
1
-
-
S&F in repair the unserviceable V belt of DG set capacity 10 KVA
2
-
-
M&L for reconditioning of unserviceable battery of capacity 12 Volt 180 AH by replacing complete cells,PVC seperators,electrolyte,terminals and final sealing ,rechargeing,battery lead,and testing all as specified and directed.
4
-
-
M&L for repair of self starter after removing from the DG set of capacity 62.5 KVA of any make and model all as specified and directed.
1
-
-
M&L for repair of self starter after removing from the DG set of capacity 125 KVA of any make and model all as specified and directed.
1
-
-
M&L for repair of dynamo after removing from the DG set of capacity 62.5 KVA of any make and model all as specified and directed.
1
-
-
M&L for repair of dynamo after removing from the DG set of capacity 10 KVA of any make and model all as specified and directed.
1
-
-
S&F of electrolyte for lead acid battery
2
-
-
S&F of distiled water for lead acid battery
2
-
-
S&F in repair diode of DG set of capacity 62.5 KVA
1
-
-
S&F in repair diode of DG set of capacity 125 KVA
1
-
-
S&F in repair diode of DG set of capacity 625 KVA
1
-
-
M&L for extension of exhaust pipe with flange ,nut,bolts,washers,elbow, bend or welding as suitable direction of suitable size of MS pipe from DG set 625 KVA exhaust pipe to out side of DG room at height of 4.0 mtr with provision of safety from rain and snow all as specified and directed by Engr in charge
1
-
-
Evaluation Notes How It Works ?
Potential Partner