Military Engineer Services Tender

... More
To know what Andhra Pradesh government has posted about any AP etender, Bidassist helps us to get a one-stop platform where a registered bidder can have access to the details on each and every eprocurement tender. There is no need to provide the details on the AP E-procurement website i.e. https://www.apeprocurement.gov.in as BidAssist helps us find the specific etender we're looking for. BidAassist has collated each and every Eproc Andhra Pradesh Tender on its website.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Eprocure
Opening Date6 May 2025
Closing Date27 May 2025
Tender Amount₹ 45,12,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Note :- The above quoted rate is inclusive of all spare parts apart from below mentioned spare parts which will be paid seperately to make the unit completely functional, T&P manpower required in the site

-

-

-

... More
All as per item No. 1.00 above, but for 5.00 TR x 2 Nos at Periscope bay bldg

11

-

-

... More
All as per item No. 1.00 above, but for 7.5 TR x 4 Nos at 29 Test house bldg

11

-

-

... More
All as per item No. 1.00 above, but for 8.0 TR x 3 Nos. at 43 bldg

11

-

-

... More
All as per item No. 1.00 above, but for 11.0 TR x 2 Nos. at MIS bldg

11

-

-

... More
All as per item No. 1.00 above, but for 11.0 TR x 2 Nos. at 17 DGM bldg

11

-

-

... More
All as per item No. 1.00 above, but for 11.0 TR x 2 Nos. at 17 lp bldg

11

-

-

... More
All as per item No. 1.00 above, but for 11.0 TR x 3 Nos. at 17 RJE bldg

11

-

-

... More
All as per item No. 1.00 above, but for 16.5 TR x 2 Nos. at 42 Library

11

-

-

... More
All as per item No. 1.00 above, but for 16.5 TR x 2 Nos. at MIT bldg

11

-

-

... More
Material and labour for de-scaling the condensers of 5 to 16.5 TR package AC units by using HCL acid agent with continuous circulation method using circulation pump, finally neutralizing with fresh water, opening both ends covers of shell and tube condenser, cleaning of copper tubes manually by using nylon brushes, re-fixing the end cover with new ‘Neoprene make’ rubber gaskets, nuts, bolts etc., and commissioning after conducting performance test of the system all as specified and directed Note:-Descalling of all the units at one location is considered as one job

44

-

-

... More
M&L for for repair/overhauling the IDU of AC unit which includes removal of outer body, compressor, condenser,cooling/evaparator coil,transducers, fan motor and disconnecting all electrical connections, refrigerant lines, condenser water pipe lines etc and removing gas keeping into safe custody for reuse or for schedule of credit. Reassembling/replacing the unit by all the spares which are taken into custody/supply only and connecting the pressure lines/control wiring, leak testing recharging the gas ,correcting alignment of fan motor, tightening of loose nuts, bolts,connecting wires etc.,complete all as specified and directed. Note : The quoted Rates are inclusive of reinstalling testing and commissioning the unit as earlier with necessary modification to refrigerant copper pipe line with silver brazing replacement of shut off valves flushing out the system which requires pressure testing with nitrogen gas under constant pressure of 250 PSI for 24 hours, vaccumization, performance test and commissioning and charging the gas to unit making alignment gas charging and necessary tinkering/brazing and making the unit completely functional etc.

26

-

-

... More
supply only new sealed scroll compressor suitable upto 16.5 TR water cooled package units complete all as specified and directed

3

-

-

... More
Supply only Microprocessor control board suitable upto 16.5 TR package unit complete all as specified and directed. Make : Bluestar/Voltas

3

-

-

... More
Supply only suction gas temperature tranduger (LP) suitable upto 16.5 TR ductable AC plant complete all as specified and directed.

3

-

-

... More
Supply only suction gas temperature tranduger (HP) suitable upto 16.5 TR ductable AC plant complete all as specified and directed.

3

-

-

... More
Supply only supply/return air temperature sensor suitable upto 16.5 TR ductable AC plant complete all as specified and directed.

4

-

-

... More
Supply only water flow switch suitable upto 16.5 TR package type AC plant complete all as specified and directed.

4

-

-

... More
Supply only evaporator coil suitable upto 16.5 TR package type AC plant complete all as specified and directed.

3

-

-

... More
Supply only thermostatic type expansion valve suitable upto 16.5 ton package unit complete all as specified and directed.

3

-

-

... More
Supply only V-Belt of existing section of any size suitable upto 16.5 TR all as specified and directed.

20

-

-

... More
Supply only new HP/LP pressure cut-out MP-15 all as specified and directed

3

-

-

... More
Supply only new Water pressure cut-out IPS-70 all as specified and directed

3

-

-

... More
Supply only new condensor shell and tube type having shell size pressure 21 Kg/sq cm and tube side 7 kg/ sq suitable upto 16.5 TR complete all as specified and directed.

1

-

-

... More
Supply only suction valve suitable upto 16.5 T package unitsall as specified and directed.

2

-

-

... More
Supply only discharge valve suitable upto 16.5 T package units all as specified and directed.

2

-

-

... More
Supply only PVC mesh Air filters with MS frame suitable upto 16.5 T package AC plants including taking out old unserviceable filter all as specified and directed.

4

-

-

... More
Supply only filter drier from package type AC unit suitable upto 16.5 TR all as specified and directed

4

-

-

... More
Supply only R-22 gas all as specified and directed.

244

-

-

... More
Supply only R-407 gas all as specified and directed.

244

-

-

... More
Material and labour for cleaning of evaporator coil with caustic soda neutralising with fresh water blowing with electric blower for package type AC unit and replacement of canvas cloth with Zip arrangement for jointing the duct as required at site, all as specified and directed.

8

-

-

... More
De-carbonizing/cleaning of LT 415/380 V, 3 phase bus bar, bus bar chambers of LT panels electrical connections complete, LT ACB, MCCB,MCB,switch fuse unit arrangement, in-coming and out-going installed in plant room and cleaning the bus bar with CTC, applying, Backtol (red) solution to the bus bar insulators, checking all the connections, tightening the nuts, bolts, thimbles duly applied with petroleum jelly to nuts, bolts and thimbles of in-coming and out-going system complete including replacement of defective rusted bolts , nuts and spring washers with new cadmium coated ones all as specified and directed.

10

-

-

... More
Note :- Items apart from supply only which are required in site are deemed to be included in the quoted rate.Material such as indication lamp, ammeter, voltmeter will be measured and paid separately as supply only.Any other items equired to make the unit functional is deemed to be included in the quoted rate.Contractor has to deploy manpower at the worksite to attend the breakdown calls received from representatives during two shifts throughout the week including sundays & holidays and on emergencies in third shift shall be attended ,preventive maintenance for the entire duration of contract.It is the contractors responsibility to make the unit functional and sufficient stock of spares shall be maintained to rectify the breakdown within scheduled period.Cleaning,stacking,sorting,handling and upkeeping of maintenance shall be carried out by contractor.

-

-

-

... More
Supply only MCCB of 250 Amps, 4 pole, 36 KA, AC supply 50Hz, 415 V complete all as specified and directed.

1

-

-

... More
Supply only MCCB of 160 Amps, 4 pole, 36 KA, AC supply 50Hz, 415 V complete all as specified and directed.

1

-

-

... More
Supply only MCCB of 100 Amps, 4 pole, 36 KA, AC supply 50Hz, 415 V complete all as specified and directed.

1

-

-

... More
Supply only MCCB upto 63 Amps, 4 pole, 36 KA, AC supply 50Hz, 415 V complete all as specified and directed.

5

-

-

... More
Supply only Power contactor 32 Amps, 3 pole, 415 V complete all as specified and directed.

3

-

-

... More
Supply and fix rubber insulating mat in front of LT panel board of size 3 mm thick, 1 M width up tp 3.3 KV all as specified and directed.

10

-

-

... More
Supply only digital electronic Ammeter (0-100 amps range) with built in selector switch suitable for LT 415 V panel flush pattern square type 96 mm x 96 mm with adopter complete all as specified and directed.

2

-

-

... More
Supply only digital electronic Volt meter (0-500 volts range) with built in selector switch suitable for LT 415 V panel flush pattern square type 96 mm x 96 mm with adopter complete all as specified and directed

2

-

-

... More
Supply only indication lamps (LED type) red, yellow and blue in colours of 22.5 mm dia to monitor on LT panel board suitable for 240 V AC supply and taking down unserviceable indication lamps all as specified and directed.

3

-

-

... More
Supply and fix pressure gauge 0-12 Kg./cm2 for water line for suction/discharge refrigerant lines and water lines of square/round type 2"/4" dial for Package AC plant including taking down old unserviceable pressure gauge complete all as specified directed

2

-

-

... More
Earthing complete with copper plate 60×60cm ×3.15mm thick electrode and 20×3mm copper strip as earthing lead, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to 20×3mm copper strip by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and directed.

13

-

-

... More
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 20 x 3mm copper strip complete all as specified and directed.

72

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.