Military Engineer Services Tender

To know what Andhra Pradesh government has posted about any AP etender, Bidassist helps us to get a one-stop platform where a registered bidder can have access to the details on each and every eprocurement tender. There is no need to provide the details on the AP E-procurement website i.e. https://www.apeprocurement.gov.in as BidAssist helps us find the specific etender we're looking for. BidAassist has collated each and every Eproc Andhra Pradesh Tender on its website.

Military Engineer Services - MES Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date26 Nov 2024
Closing Date21 Dec 2024
Tender Amount₹ 1,73,40,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Get the Best Price For TMT
Starting from
₹51,000/MT*
Andhra Pradesh

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Excavation over areas depth exceeding 1.5m but not exceeding 3 m in depth and getting out in Soft / loose complete all as specified and as directed.

13.65

-

-

... More
Excavation in trenches not exceeding 1.5m wide and not exceeding 10 Sq.m on plan area and not exceeding 1.5m deep in Soft / loose soil complete all as specified and as directed.

76

-

-

... More
Excavation in trenches not exceeding 1.5m wide and not exceeding 10 Sq.m on plan area and exceeding 1.5m but not exceeding 3.0 m deep in Soft / loose soil complete all as specified and as directed.

28

-

-

... More
Excavation in trenches not exceeding 1.5m wide and not exceeding 10 Sq.m on plan area and not exceeding 1.5m deep in hard / dense soil complete all as specified and as directed.

411

-

-

... More
Excavation in any type of soil by mechanical means (Hydraulic excavator) means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m, complete all as specified and as directed.

302.7

-

-

... More
Returning, filling in foundation trenches with excavated soil including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed.

360.5

-

-

... More
Removal of excavated material [Soil] to a distance exceeding 50m but not exceeding 250m and depositing where directed all as specified and as directed.

75

-

-

... More
Removal of excavated material [Soil] to a distance not exceeding 50m and depositing where directed all as specified and as directed.

426.2

-

-

... More
Boring for bored cast-in-situ piles 500mm dia in any strata except Soft Disintegrated Rock / Hard Rock and getting out and disposal of spoil out side MD land using Hydraulic Rotary Rig complete all as specified and directed. Note: Truck mounted Rotary / TMRT / Tube well boring Machine shall not be used.

900

-

-

... More
Boring for bored cast-in-situ piles 500mm dia in Soft Disintegrated Rock / Hard Rock and getting out and disposal of spoil out side MD land using Hydraulic Rotary Rig complete all as specified and directed. Note: Truck mounted Rotary / TMRT / Tube well boring Machine shall not be used.

100

-

-

... More
M & L for Moorum / Red Bajri filling under Floors or in Pavings laid in layers not exceeding 30 cm thick, spread levelled and rammed / rolled including watering to required level and gradient complete all as specified and as directed

84.5

-

-

... More
Hardcore of gauge not exceeding 63 mm of broken stones or boulders, deposited, spread and levelled in layers not exceeding 15 cm thick watered and rolled with power road roller of 8 to 12 ton capacity and consolidated to required gradient and camber complete all as specified.

36.25

-

-

... More
M & L for sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed.

2

-

-

... More
Dry River Sand cushioning over and around the cable in trenches, levelled and punned down complete all as specified and as directed. Note: The punned down thickness shall be measured for payment.

67

-

-

... More
Bricks, common burnt clay building bricks, sub-class ‘B’ designation 75, size 230mm x 115mm 75mm, laid in trenches as in cable protection complete all as specified and as directed.

7

-

-

... More
M & L for PCC 1:3:6, Type C-2, using 40mm graded stone aggregate as in Foundation, Fillings, Mass concrete, Footings etc complete all as specified and as directed.

126.5

-

-

... More
M & L for PCC 1:3:6, Type C-2, using 20 mm graded stone aggregate as in surface channels, drain beds etc complete all as specified and directed.

0.4

-

-

... More
PCC 1:4:8, Type D–2, using 40mm graded stone aggregate as in Foundation, Fillings, Mass concrete, Footings etc complete all as specified.

19.13

-

-

... More
M & L for PCC 1:2:4, Type B-2, using 40mm graded stone aggregate as in Foundation, Fillings, Mass concrete, Footings etc complete all as specified and as directed.

25.76

-

-

... More
M & L for 150 mm thick PCC 1:2:4, Type B-2, using 40mm graded aggregate as in sub base complete all as specified and as directed.

75

-

-

... More
M & L for SRFC factory made manhole cover for using cover to manholes complete all as specified and as directed.

5

-

-

... More
M & L for Providing Precast Cement Concrete Solid Block Masonry of 1:3:6, Type C1 using 20mm graded stone aggregate exceeding 100mm width with plain or interlocking joints set in cement mortar 1:6 complete all as specified and as directed.

79.5

-

-

... More
M & L for 75 mm thick PCC 1:4:8, Type D-2, using 40 mm graded stone aggregate as in Sub base for flooring complete all as specified and as directed.

171

-

-

... More
M & L for 75mm thick PCC 1:3:6, Type C-1, using 20mm graded aggregate as in Plinth protection etc surface finished even and smooth with out using extra cement and providing 12mm thick joints for full depth of PCC at every 3.00 m and every change of direction duly filled with mastic filling comprising of 01 Part of heated bitumen blown grade of any penetration and 3 parts of sand [all by weight] complete all as specified and as directed.

130.95

-

-

... More
M & L for 25 mm thick PCC 1:2:4, Type B-0, using 12.5mm graded aggregate as in levelling course / sub base for flooring, complete all as specified and as directed.

171

-

-

... More
M & L for Non Skid Ceramic Tiles, Joint Free, Coloured, Premium Quality of size exceeding 0.11 Sq.m and not exceeding 0.18 Sq.m, 7 to 8 mm thick [Square or Rectangular] as in Floors etc, set and jointed in neat cement slurry and pointed flush using polymer based cementitious tiling joint filler to match the shade of the tile including screed bed or bedding layer of mortar 15 mm thick in Cement Mortar 1:4 complete all as specified and as directed. Note: The colour / shade / design of tiles shall be as approved by GE.

107

-

-

... More
M & L for Non Skid Ceramic Tiles, Joint Free, Coloured, of size exceeding 0.11 Sq.m and not exceeding 0.18 Sq.m, 7 to 8 mm thick [Square or Rectangular] as in vertical Surfaces such as Skirting, Dado etc, set and jointed in cement slurry and pointed flush using polymer based cementitious tiling joint filler to match the shade of the tile over backing coat of 10mm thick in Cement Mortar 1:3 complete all as specified and as directed. Note: The colour / shade / design of tiles shall be as approved by GE.

10

-

-

... More
M & L for Non Skid Ceramic Tiles, Joint Free, Coloured, Premium Quality of size exceeding 0.06 Sq.m and not exceeding 0.11 Sq.m, 7 to 8 mm thick [Square or Rectangular] as in Floors etc, set and jointed in neat cement slurry and pointed flush using polymer based cementitious tiling joint filler to match the shade of the tile including screed bed or bedding layer of mortar 15 mm thick in Cement Mortar 1:4 complete all as specified and as directed. Note: The colour / shade / design of tiles shall be as approved by GE.

20

-

-

... More
M & L for Joint Free Glazed Ceramic Tiles, Edge Cut, Concept Type, Coloured, Premium Quality, of size 350mmX250mm/450 mm X 350 mm, 7 to 8 mm thick as in Vertical Surfaces such as Skirting, Dado etc set and jointed in neat cement slurry and pointed flush using polymer based cementitious tiling joint filler to match the shade of the tile over backing coat of 10mm thick in Cement Mortar 1:3 complete all as specified and as directed. The colour / shade / design of tiles shall be as approved by GE.

90

-

-

... More
M & L for Kota Stone Slabs of 20 to 25 mm thick in vertical surfaces of Gallery platforms, Skirting, Dado, Risers of Steps, Jambs, Pillars etc. with machine cut edges, including diagonals, inlays, borders, margins in two or more colours / shades, designs / patterns of stone slabs, set and bedded with Grey Cement [slurry] and jointed and pointed with grey cement slurry mixed with a admixture of pigment to match shade of Slabs, rubbing and grinding with mechanical equipment fitted with suitable grit size corborundum stones and polishing with Oxalic Acid to smooth, bright mirror finish over backing coat of 10mm thick in Cement Mortar 1:3 complete all as specified and as directed. Note: Single stone slab shall be used for entire height of skirting / dado / risers and joints shall match with the flooring.

120

-

-

... More
M & L for Powder coated aluminium sections [Minimum 50 Micron thick] of approved colour for Doors, Windows, Ventilators, Partitions with frame and shutters fully or partly glazed, sliding / openable including necessary jointing cleats, glazing clips, rubber beading, neoprene packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as handles, aluminium butt hinges, aluminium tower bolts, stainless steel friction hinges, locking arrangements etc., complete all as specified and as directed. Notes: [a] The size of aluminium sections shall be all as specified in relevant IS code and MES Schedule Part - I. [b] Weight of aluminium sections shall only be accounted for payment purpose. Weight of aluminium Handles, Butt Hinges & Tower Bolts shall not be accounted for payment purpose. [c] The unit rate quoted shall be deemed to include for cost of jointing cleats, glazing clips, rubber beading, neoprene packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as handles, aluminium butt hinges, aluminium tower bolts, stainless steel friction hinges, locking arrangements etc..

450

-

-

... More
S & F Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening complete all as specified and as directed.

23

-

-

... More
S & F only 4.8mm thick Tinted Glass ordinary quality in squares not exceeding 0.5 Sq.m in each pane complete all as specified and as directed.

23

-

-

... More
S & F Solid PVC door frame of size 50mmX47mm made out of 5mm wood grain printed PVC sheet reinforced with MS square tube fixed in opening including edges painted to match with printed sheet complete all as specified and as directed.

47

-

-

... More
S & F Factory made solid panel PVC door shutter 30 mm thick [Style] consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded wood grain printed PVC "C" Channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and wood grain printed PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, Panelling of wood grain printed PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with 5mm thick x 15mm wide PVC sheet beading used inside stiles and rails and decorative PVC beading of 10mm x 10mm (90°), and joined together with solvent cement fixing in frame at site as per specification complete all as specified and as directed.

14

-

-

... More
M & L for providing Precast RCC 1:2:4, Type B-1 using 20mm graded stone aggregate as in landings, cover slabs [for manholes etc], chullah hoods, chajjas, water troughs, mangers, Shelves and similar articles with plain faces set in cement mortar 1:4 complete all as specified and as directed.

1

-

-

... More
M & L for PCC 1:2:4, Type B-1, using 20 mm graded stone aggregate as in Coping, Bed plate, cill and the like including weathering, slightly rounded or chamfered angles and throating including formwork [straight or curved] complete all as specified and directed.

3.8

-

-

... More
M & L for RCC M-40 design mix, using 20mm graded stone aggregate as in Pile complete all as specified and as directed.

196.25

-

-

... More
M & L for chipping out pile up to cutoff level including disposal up to distance of 50m complete all as specified and directed.

2

-

-

... More
M & L for RCC M-30 Design Mix, using 20mm graded stone aggregate as in Beams, cantilevers, bressummers, lintels etc. complete all as specified.

135

-

-

... More
Use and waste of form work to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc, splays between floors and beams and similar works for fair finished surfaces of concrete complete all as specified and as directed.

420

-

-

... More
M & L for RCC M-30 Design Mix, using 20mm graded stone aggregate as in Columns, pillars, piers, posts and struts etc. complete all as specified.

130

-

-

... More
Use and removal of steel formwork to sides of pillars, posts, struts, piers, columns and stanchions of any shape / cross section for fair finished surfaces of concrete complete all as specified and as directed.

700

-

-

... More
M & L for RCC M–30 Design Mix, using 20mm graded stone aggregate as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed.

130.4

-

-

... More
M & L for RCC M-30 Design Mix, using 20mm graded stone aggregate as in Walls, Retaining Walls, Basement Walls, Ballast Walls and the like, any thickness above top of footings including attached pilasters and buttresses etc complete all as specified.

24.3

-

-

... More
M & L for RCC M-30 Design Mix, using 20mm graded stone aggregate as in Slabs supported on walls, beams, columns in floors, roofs, landings, balconies, canopies, deck slabs complete all as specified and as directed.

145

-

-

... More
Use and removal of steel formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits [if any] of foundation and plinth beams and similar work, vertical or to batter for rough finished surfaces complete all as specified and as directed.

586

-

-

... More
Use and removal of steel formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick [horizontal or sloping] including fair finished surfaces complete all as specified and directed.

1202

-

-

... More
Use and removal of steel formwork [Plain / Curved] to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pilasters, buttresses, etc. vertical or to batter for ROUGH finished surfaces of concrete complete all as specified.

102

-

-

... More
M & L for Carrying out Initial Load Test on 500mm dia bored cast–in–situ piles as per IS – 2911 [Part – IV] complete all as specified and as directed. [Note: Safe Design Load of the Pile is 56 MT]

5

-

-

... More
M & L for Carrying out Routine Load Test on 500mm dia bored cast–in–situ piles as per IS – 2911 [Part – IV] complete all as specified and as directed. [Note: Safe Design Load of the Pile is 56 MT]

5

-

-

... More
M & L for Carrying out low strain integrity Test on 500mm dia bored cast–in–situ piles including analysing the result as per ASTM D 5882 complete all as specified and directed.

5

-

-

... More
M & L for Carrying out lateral Load Test on 500mm dia bored cast–in–situ piles as per IS specifications complete all as specified and as directed.

45

-

-

... More
Demolition of Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles all as specified and as directed.

48.96

-

-

... More
Demolition of plain cement concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) all as specified and as directed.

21.6

-

-

... More
Taking down Chowkats or frame with shutters [without taking off shutter from the frame] not exceeding 1.5 Sq.m each complete all as specified and as directed.

20

-

-

... More
Demolition of reinforced cement concrete Roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work, reinforcement cut as required to facilitate demolition including cutting reinforcement reinforcement to facilitate demolition all as specified and as directed.

80.51

-

-

... More
Removing building materials etc. (other than spoil) to a distance exc. 4.5 Km but n. exc. 5 Km, beyond the lead included in the rates, including loading, unloading and stacking at the destination all as specified and as directed.

25

-

-

... More
S & F Reinforcement using High Strength Corrosion Resistant Deformed TMT Bars of Grade Fe–500D of 10mm dia and over, cut to length, bent to shape required including cranking, bending, spirally for hooping, hooking ends and binding with annealed mild steel wire not less than 0.9mm dia or securing with clips or welded complete all as specified and as directed.

90681.64

-

-

... More
S & F Reinforcement using High Strength Corrosion Resistant Deformed TMT Bars of Grade Fe–500D of 5mm to 10mm dia bars as in stirrups, spacers and binders, cut to length, bent to shape required including cranking, bending, spirally for hooping, hooking ends and binding with annealed mild steel wire not less than 0.9mm dia or securing with clips or welded complete all as specified and as directed.

22500

-

-

... More
S & F Mild Steel work confirming to Fe - 290, Grade E-165, as in framed work such as Grills, Gratings, Ladders etc with ends of bars shouldered and/or riveted, or forged into spikes, framed Guard Bars, Barred Iron Doors, Ladders, framed Balusters, Walk Ways, Railings, framework of Water Tanks and similar work complete all as specified and as directed.

120

-

-

... More
M & L for two coats of Synthetic Enamel paint over one coat of Red Oxide / Zinc Chrome Primer on new steel surfaces over 10cm width or girth including preparation of surfaces complete all as specified and as directed.

25

-

-

... More
S & F CPVC Pipes 20 mm outer diameter SDR 11 & Plain CPVC SDR 11 Fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc fixed to walls, ceiling or laid on floors including testing complete all as specified and as directed.

30

-

-

... More
S & F CPVC Pipes 25 mm outer diameter SDR 11 & Plain CPVC SDR 11 Fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc fixed to walls, ceiling or laid on floors including testing complete all as specified and as directed.

15

-

-

... More
S & F CPVC Pipes 32 mm outer diameter SDR 11 & Plain CPVC SDR 11 Fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc fixed to walls, ceiling or laid on floors including testing complete all as specified and as directed.

30

-

-

... More
S & F GI water tubing of 25 mm bore, medium grade conforming to IS - 1239 [Part - 1] including all fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc fixed to walls, ceiling or laid on floors complete all as specified and as directed.

880

-

-

... More
S & F GI water tubing of 40 mm bore, light grade conforming to IS - 1239 [Part - 1] including all fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc fixed to walls, ceiling or laid on floors complete all as specified and as directed.

24

-

-

... More
S & F GI water tubing of 50 mm bore, medium grade conforming to IS - 1239 [Part - 1] including all fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc fixed to walls, ceiling or laid on floors complete all as specified and as directed.

50

-

-

... More
S & F 110mm bore PVC [SWR] pipes single socketed, in any length with rubber ring joints,laid in trenches or in floors including necessary brackets, clamps as in rain water down pipes complete all as specified and as directed.

10

-

-

... More
S & F 110mm bore PVC [SWR] pipes single socketed, in any length with rubber ring joints, fixed to walls including necessary brackets, clamps as in rain water down pipes complete all as specified and as directed.

30

-

-

... More
S & F 75mm bore PVC [SWR] pipes single socketed, in any length with rubber ring joints, fixed to walls including necessary brackets, clamps as in rain water down pipes complete all as specified and as directed.

20

-

-

... More
S & F 110 mm bore PVC [SWR] Bends of any radius including jointing with solvent cement complete all as specified and as directed.

15

-

-

... More
S & F 75 mm bore PVC [SWR] Bends of any radius including jointing with solvent cement complete all as specified and as directed.

15

-

-

... More
S & F 110 mm bore PVC [SWR] branch piece, Single [Single "Y"] equal or unequal with access door including jointing with solvent cement complete all as specified and as directed.

5

-

-

... More
S & F 110 mm bore PVC [SWR] Junction Single [Single "T"] equal or unequal with access door including jointing with solvent cement complete all as specified and as directed.

5

-

-

... More
S & F 75 mm bore PVC [SWR] Junction Single [Single "T"] equal or unequal with access door including jointing with solvent cement complete all as specified and as directed.

5

-

-

... More
S & F 75mm outlet PVC [SWR] Multi Floor Trap with grating including jointing with solvent cement complete all as specified and as directed.

10

-

-

... More
S & F Vitreous China Wash Down Water Closet [Pedestal pattern], White, including 10 Litres capacity, PVC Valve less, Syphonic action type, low level flushing cistern (dual flush), white, with inlet ball valve, float, handle, flush pipe of polyethylene of low or high density of PVC, 32mm dia, PVC Connection of 15mm Bore and 600mm long with PTMT check nut and union etc. including brackets and connections to pipe and flush pipe including plastic water closet seat back closed pattern with flat bottom and cover and mild steel chromium plated or aluminium hinging device and 'P' or 'S' trap complete all as specified and as directed.

5

-

-

... More
S & F Health Faucet, ABS body,mild steel chromium plated suitable for 15 mm dia pipe including 1.25 m long flexible tube, ABS wall hook, non return valve complete all as specified.

5

-

-

... More
S & Vitreous China Ware Wash Hand Basin, White, Flat Back of size 550 mm X 400 mm including brass chromium plated waste fittings with long screw shanks and fly nuts, flange end bedded in red led cement and other end fixed, rubber plug with rings including CI Brackets, cutting for and pinning in ends of brackets or erecting strand, 32mm bore PVC flexible waste pipe, PVC Connection of PTMT complete all as specified and as directed.

5

-

-

... More
S & F Brass Chromium Plated Shower Rose of size 125mm with or with out swivel joints fixing to steel pipes complete all as specified and as directed.

5

-

-

... More
S & F Pillar Taps, cast copper alloy, Chromium Plated, Fancy Type, 15 mm dia, with capstan head, screwed down high pressure with or with out lettered "Hot" or "Cold" with long screwed shanks and fly nuts screwed for iron pipe and fixed complete all as specified.

10

-

-

... More
S & F Bib Taps, 15 mm dia, Brass Chromium Plated, Fancy Type with crutch or butterfly handle, screwed down for iron pipe and fixed etc. complete all as specified and as directed.

5

-

-

... More
S & F Bib Taps, 15 mm dia, brass, Chromium Plated, Fancy Type, long Body with crutch or butterfly handle, screwed down for iron pipe and fixed etc. complete all as specified and as directed.

5

-

-

... More
S & F Stop Valves, 15 mm bore dia of pipe, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions etc complete all as specified and as directed.

5

-

-

... More
S & F Stop Valves, 15 mm dia, cast copper alloy with capstan head, Chromium Plated, Fancy Type, screwed down high pressure with crutch or butterfly handle with long shank and cup [concealed type] for iron pipe etc complete all as specified and as directed.

15

-

-

... More
S & F Bevelled Edge Mirror of selected quality glass, 6 mm thick, mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plug with CP brass screws and cup washers complete all as specified and as directed.

5

-

-

... More
S & F Brass Chromium Plated Tubular Towel Rail, 20mm dia, D Type, 600 mm long between flanges complete all as specified and as directed.

5

-

-

... More
S & F PVC Connection of 15mm Bore and 450mm long with PTMT check nut and union etc. complete all as specified and as directed.

15

-

-

... More
S & F PTMT Grating Doom, 100 mm dia [Minimum weight 25 Grams] without waste hole or with waste hole to insert waste pipe complete all as specified and directed.

5

-

-

... More
S & F 125/110mm bore PVC [SWR] Gully Trap with grating including jointing with solvent cement complete all as specified and as directed.

5

-

-

... More
S & F 12mm thick, Prelaminated Particle Board, Decorative Choice Lamination on Both Sides, Medium Density, Exterior Grade complete all as specified and as directed.

4

-

-

... More
S & F Floor Door Stopper of size 140 mm of aluminium alloy body and tongue, anodised, with hard drawn steel spring complete all as specified and as directed.

5

-

-

... More
S & F 100 mm size, medium weight Butt Hinges, cold rolled, mild steel including fixtures complete all as specified and as directed.

30

-

-

... More
S & F Aluminium anodised Handle, of extruded section Fabricated Type of size 150mm long complete all as specified and as directed.

20

-

-

... More
S & F Aluminium anodised barrel Tower Bolt of size 150 mm size of extruded section complete all as specified and as directed.

20

-

-

... More
S & F Stainless steel wire cloth / mesh with average aperture not exceeding 1.40 mm and dia of wire 0.36 mm and fixed with tinned tacks or Aluminium wire staples with new wooden beading including necessary painting to beading to match with existing surfaces complete all as specified and as directed.

20

-

-

... More
S & F Gun Metal Globe or Gate Valve of Class - I, Pressure Tested of 1.5 Mpa, 25 mm bore with iron wheel head, screwed both ends for iron pipe, conforming to IS, ISI Marked complete all specified and as directed.

13

-

-

... More
S & F Gun Metal Globe or Gate Valve of Class - I, Pressure Tested of 1.5 Mpa, 32 mm bore with iron wheel head, screwed both ends for iron pipe, conforming to IS, ISI Marked complete all specified and as directed.

5

-

-

... More
Cutting screwing existing CI/GI pipes of 25 mm dia for alterations or additions (Each cut measured) complete all specified and as directed.

5

-

-

... More
Rerouting of existing CI/GI pipes of size up tlo 50 mm dia by disconnecting all connections and refixing including necessary fittings complete all specified and as directed.

150

-

-

... More
S & F Rotational Moulded Polythene [HDPE] Water Tanks, Double Layered, ISI Marked, Cylindrical & Vertical Type 500 Litres Capacity hoisted and fixed in position including provision of 40mm/25mm dia spouts for connecting inlet, outlet, over flow and washout pipes complete all as specified and as directed.

5

-

-

... More
M & L for 150mm dia RCC Pipes, Class NP3, laid and jointed with collars laid in trenches and jointed with cement mortar complete all as specified and as directed.

30

-

-

... More
M & L for 600mm dia RCC Pipes, Class NP3, laid and jointed with collars laid in trenches and jointed with cement mortar complete all as specified and as directed.

15

-

-

... More
M & L for 150 dia for Salt Glazed Stoneware Drain Pipes of Grade "A" laid in trenches and jointed complete all as specified and as directed.

50

-

-

... More
M & L for Concrete bed to drain pipes of size 150 mm bore packing under and haunching against the sides of pipes after they are laid and fitted in cement concrete, Type C2, 1:3:6, using 40mm graded stone aggregate complete all as specified and as directed.

50

-

-

... More
M & L for brick work with Fly Ash bricks, straight or curved on plan exceeding 6 m mean radius built in Cement Mortar 1:6 complete all as specified and as directed.

60

-

-

... More
M & L for brick work in half brick thick walls using Fly Ash bricks straight or curved on plan to any radius built in Cement Mortar 1:4 including 2 Nos of 8mm dia bars at every fourth course of brick work complete all as specified and as directed.

50

-

-

... More
Supply only integral water proofing compound [ISI marked] of approved make.

222

-

-

... More
M & L for Rendering to brick masonry/concrete surfaces, 15 mm thick in Cement Mortar 1:4, surfaces finished even and smooth without using extra cement complete all as specified.

1151

-

-

... More
M & L for Rendering to brick masonry/concrete surfaces, 15 mm thick in Cement Mortar 1:6, surfaces finished even and smooth without using extra cement complete all as specified.

600

-

-

... More
M & L for rendering to brick / concrete surfaces, 15 mm thick in Cement Mortar 1:4, including mixing water proofing compound as per manufacturers instructions and finishing the top surface even and smooth without using extra cement complete all as specified and as directed.

12.48

-

-

... More
M & L for rendering to other than fair faces of brick work, 15 mm thick in Cement Mortar 1:6 and finishing the top surface even and smooth without using extra cement complete all as specified and as directed.

20.4

-

-

... More
M & L for rendering 5 mm thick on fair faces of brick in Cement Mortar 1:3 finished even and smooth without using extra cement complete all as specified and as directed.

625

-

-

... More
M & L for Two coats of Weather Proof Exterior Emulsion Paint [100% Acrylic] by using auto roller/ airless sprayer over a Coat of Exterior Primer over 1mm thick Cement based Wall Care Putty [primer and putty shall be of same manufacturer as that of exterior emulsion paint] by using multipurpose mixture for proper mixing of putty and putty sprayer for application of putty on newly plastered walls/ ceiling, pillasters, bands, borders, soffits of chajjas and projections including rubbing with sand paper to obtain a smooth surface complete all as specified and as directed. Note:- The contractor shall carryout Exterior Emulsion Painting and allied works under subject work through the Authorised Applicator of the manufacturer only. The lowest bidder shall submit MoU from manufacturer to provide technical support and trained persons for carrying out Exterior emulsion painting through their authorised applicators before commencement of the work to GE for approval.

835

-

-

... More
M & L for preparing newly plastered wall surfaces and applying three coats of white washing complete all as specified and as directed.

32

-

-

... More
M & L for preparing newly plastered Ceiling surfaces and applying three coats of white washing complete all as specified and as directed.

460

-

-

... More
M & L for Preparing surfaces by brushing with wire brushes for removing caked mud etc. sweeping with brooms and finally fanning the cleaned surfaces with gunny bags to remove all dirt etc. and applying evenly a priming / tack coat with bituminous primer at 5 KG per 10 Sq.m of paving bitumen of grade VG - 30 complete all as specified and as directed.

37.5

-

-

... More
M & L for bituminous macadam not exceeding 75 mm thickness (compacted thickness) using hot mix plant and mechanical paver with 4% binder (paving grade bitumen VG-30 grade) content by weight of total mix, rolled and compacted with power roller 8 to 10 tonnes to required camber and gradient complete all as specified and as directed. Note :- (i) Bituminous macadam shall be laid using self propelled hydrostatic paver finisher and preparation of mix shall be using hot mix plant and transporting the mix in tipper. (ii) The exact bitumen content required shall be determined as per IRC 27: 2009. The adjustment in rate due to variation in quantity of bitumen if any shall be priced at the rate of ₹44 per kg.

11.25

-

-

... More
M & L for laying Bituminous Premixed Semi Dense Asphaltic Concrete, 40 mm consolidated thickness, using paving bitumen of Grade VG – 30, with 5.5% of binder content by weight of total mix using Hot Mix Plant and Mechanical Paver, rolled and compacted with power road roller of 8 to 12 ton capacity to required camber and gradient complete all as specified. Note: Minimum Bitumen content shall be 5.5% as specified here in above. Please note that if the actual quantity of bitumen to be incorporated on approval of Mix–Design is found more than the minimum bitumen content specified above, No price adjustment shall be made for actual bitumen content of Mix–Design. Bitumen shall be Paving Bitumen of Grade VG–30 and shall be procured by the contractor.

37.5

-

-

... More
S & F Road Stud, Two way reflective of size 100mm X 110mm X 20 mm [Approximately], ABS body with high intensity grade retro reflective panel of Amber, Red or White colour conforming to IRC - 67, fixed with complete all as specified and as directed.

10

-

-

... More
Supply and fix solar cat eye aluminum alloy shall (100% water proofing design according to 65) of size 125mm x 125mm x 25mm (shank 65mm) of high efficiency Mono rystafie solar panel 2.4V/ 0.3 watt one NI-ed rechargeable battery (1.2V/ 1600MA) consisting of super bright LED with 10,000 to 18,000 mcd completed as per manufactures instructions etc. all as specified and directed

10

-

-

... More
M & L for preparing bituminous surfaces of road and marking 2.5mm thick centre lines, stop lines, dashes, arrows etc. and the like n. exc 10cm wide on roads pavements with hot applied thermo plastic road marking paint of approved colour confirming to BS 3262-1989 with special applicator machine all as per manufacturers instruction complete all as specified and directed.

180

-

-

... More
M & L for Prepairing surfaces of new concrete floor by picking, sweeping clean and washing down with water to remove dust etc and brushing neat cement slurry with 3.0 KG of cement per Sq.m area, rendering 10mm thick in cement mortar 1:3 on concrete surfaces finished even and smooth without using extra cement including mixing of water proofing compound of approved make as per manufacturers instructions for levelling the surface smooth to receive the water proofing membrane, priming the surface with a coat of cold applied bituminous primer @ 0.50 KG per Sq.m, applying a coat of Blown Bitumen of grade 85/25 @ 1.2 Kg per Sq.m, laying Polymeric water proofing membrane of weight not less than 3.00 Kg per Sq.m reinforced with polyester non-woven fabric of weight not less than 150 Grams per Sq.m, by torch application with side over lap of 100mm & end over lap of 150mm & tucked into the chases on vertical surfaces by thermo fusion including applying a coat of Blown Bitumen of grade 85/25 @ 1.2 Kg per Sq.m on top and finished with a coat of bituminous aluminium paint @ 100 grams per Sq.m on top for water proofing treatment complete all as specified and as directed. Note: Water proofing compound will be measured and paid separately.

105

-

-

... More
M & L for Prepairing surfaces of new concrete roof by picking, sweeping clean and washing down with water to remove dust etc and brushing neat cement slurry with 3.0 KG of cement per Sq.m area, rendering 10mm thick in cement mortar 1:3 on concrete surfaces finished even and smooth without using extra cement including mixing of water proofing compound of approved make as per manufacturers instructions for levelling the surface smooth to receive the water proofing membrane, priming the surface with a coat of cold applied bituminous primer @ 0.50 KG per Sq.m, applying a coat of Blown Bitumen of grade 85/25 @ 1.2 Kg per Sq.m, laying Polymeric water proofing membrane of weight not less than 3.00 Kg per Sq.m reinforced with polyester non-woven fabric of weight not less than 150 Grams per Sq.m, by torch application with side over lap of 100mm & end over lap of 150mm & tucked into the chases on vertical surfaces by thermo fusion complete all as specified and as directed. Note: Water proofing compound will be measured and paid separately.

245

-

-

... More
M & L for Plain Cement Concrete Tiles of size 250 X 250 mm / 300 X 300 mm, 22mm thick, Hydraulically pressed as in Floors, set jointed and pointed in neat cement slurry to match including screed bed or bedding layer of mortar 15 mm thick in Cement Mortar 1:4 of cement complete all as specified and as directed.

245

-

-

... More
Taking down carefully copper / aluminium point wiring [light, fan, socket or power] complete including fittings such as switches, ceiling roses, pendants, regulators, sockets etc. and making good the disturbed surfaces all as per existing complete all as specified and as directed.

50

-

-

... More
Taking down existing unserviceable ceiling fans of any description and size and depositing into MES stores complete all as specified and as directed.

5

-

-

... More
Taking down existing LED tube light fittings of any description and making good the disturbed surfaces to match with existing complete all as specified and as directed

20

-

-

... More
Taking down old unserviceable submain wiring of any size and wooden battens / conduits / casing capping and making good the disturbed surfaces all as per existing complete all as specified and as directed.

100

-

-

... More
Taking down MCCB DBs, MCB DBs, SPN / TPN Enclosures including MCCBs, MCBs etc of any description and any capacity and making good the disturbed surfaces all as per existing complete all as specified and as directed.

5

-

-

... More
Taking down old unserviceable LT XLPE Cable of any size complete all as specified and as directed.

100

-

-

... More
M & L for Point Wiring complete with 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, Two runs, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, conforming to IS - 694 drawn through and including heavy duty PVC Conduit, 20 mm dia including all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type and Metal GI Flush Box of suitable size and thickness including Modular type Base / Grid Frame & Cover Frame for housing Modular Type Switches, Sockets and Regulators etc. concealed in walls, including 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable as earth continuity conductor with colour coding and connecting to Earth Dolly for One Light / Fan Point / Bell Point complete all as specified and as directed.

109

-

-

... More
All as per Serial Item No. 136 above but One 3 Pin Switch Socket Outlet 5 Amps on same Board with other switch complete all as specified.

10

-

-

... More
All as per Serial Item No. 136 above but One 3 Pin Switch Socket Outlet 5 Amps on Independent Board complete all as specified.

20

-

-

... More
All as per Serial Item No. 136 above but one 3 Pin Switch Socket Outlet 15 Amps power point on independent board, with 1100 Volts, FRLS grade, 4 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable confirming to IS - 694 and including 1100 Volts, FRLS grade, 4 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable as Earth Continuity Conductor.

15

-

-

... More
All as per Serial Item No. 136 above but One light point controlled by 2 Nos of Two way switch complete all as specified.

9

-

-

... More
Modular Switch, One Way, 6 Amps, One Module all as specified and as directed.

139

-

-

... More
Modular Switch, One Way, 16 Amps, One Module all as specified and as directed.

15

-

-

... More
S & F Switch, Modular Type, One Module, Single Pole, Two Way, 6 Amps, 230 Volts complete all as specified and as directed.

18

-

-

... More
S & F Ceiling Rose, PVC Body, 65 X 50 mm, Three Terminals, 230 Volts complete all as specified and as directed.

113

-

-

... More
S & F Socket Outlet, 3 Pin, 5 Amps, Modular Type, Two Modules, 230 Volts, complete all as specified and as directed.

25

-

-

... More
S & F Socket Outlet, 3 pin, 16 Amps cum 6 Amps, Modular Type, Two Modules, Multipurpose, 230 Volts complete all as specified and as directed.

10

-

-

... More
S & F Electronic Fan Regulator, Stepped Type, Modular Type, Two Module, 120 W, AC, 230 Volts, Single Pole complete all as specified and as directed.

15

-

-

... More
XLPE insulated, armoured heavy duty electric under ground cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 sq. mm, 4 Core complete all as specified and as directed.

900

-

-

... More
S & F Surface & wall mounted Energy efficient LED Tube Light Fitting, of not less than 1800 Lumens output, 5700 K of cool white, with extruded aluminium / CRCA housing and robust construction with necessary acrylic diffuser & integrated electronic driver, all accessories internally prewired and connecting up with twin core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm complete all as specified and as directed. Note: Light fitting shall be of PF0.95

43

-

-

... More
S & F Energy efficient Sleek decorative LED Light Fitting of not less than 900 Lumens, 2 feet long Surface & Wall mounted with Acrylic / PMMA diffuser for soft glare free light with all accessories internally prewired and including connecting up with twin core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm and making good the disturbed surfaces to match with existing complete all as specified and as directed. Note: Light fitting shall be of PF0.95

25

-

-

... More
S & F LED Bulb of not less than 900 Lumens output, 3000 K, IP40 operating voltage 90-270 Volts, AC, 50 Hz, Natural white colour complete all as specified and as directed.

10

-

-

... More
S & F Energy efficient & Long life Street Light Luminaire, of not less than 3000 Lumens output, 5700 K with Pressure Die Cast Aluminium Housing, IP66 protection, heat resistant glass cover, high power LEDs as light source, electronic driver including GI Bracket made out of 32 mm bore GI Tube, Medium Grade of size not exceeding 1.50 m in length and bent to shape required and fixed with 2 Nos of Pole fitting Clamps made out of MS Flat of size 50 X 6mm, bolts, nuts, washers and painting with two coats of aluminium paint over a coat of primer red oxide zinc chrome primer and connecting up with three core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm complete all as specified and as directed. Note: Light fitting shall be of PF0.95

20

-

-

... More
S & F MCB DB, TPN, 4 Way, 415 Volts, with DIN Channel, Double Door with 200 Amps rated bus bar suitable for mounting MCBs flush mounted with wall complete all as specified and as directed.

5

-

-

... More
S & F MCB DB, SPN, 4 Way, 240 Volts, with DIN Channel, Double Door with 200 Amps rated bus bar suitable for mounting MCBs flush mounted with wall complete all as specified and as directed.

5

-

-

... More
S & F MCB, SP, 6 to 32 Amps, 10 KA, C Curve, AC, 240 Volts, 50 Hz complete all as specified and as directed.

40

-

-

... More
S & F MCB, TPN, 16 to 32 Amps, 10 KA, 'C' Curve, AC, 415 Volts, 50 Hz complete all as specified and as directed.

5

-

-

... More
S & F MCB, SPN, 16 to 32 Amps, 10 KA, C Curve, AC, 240 Volts, 50 Hz complete all as specified and as directed.

5

-

-

... More
S & F Energy efficient, Low Noise, Ceiling Fan, 1200mm Sweep of any colour as approved, 03 blades, BEE 5 Star Rated, with BLDC Motor, Copper Wound, 350 RPM, with Double Ball Bearing, Conforming to IS - 374, ISI Marked, suitable for operation on Single Phase, 240 Volts, AC, 50Hz, including Down Rod, Canopies, Shackles, Safety Rope, Hanging Clamps, Bushes, having P.F 0.95, Service Value 6.5, Air Delivery 215 CMM, Power Consumption less than 35 Watt, THD less than 5% including provision of Electronic speed control Regulator step type, including connecting up with three core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm complete all as specified and as directed. Note: Ceiling Fan shall be provided with 03 Years onsite replacement warranty. Rate quoted is deemed to be including the same and nothing shall be paid extra on this account.

15

-

-

... More
S & F Exhaust Fan, 300mm Sweep, 1400 RPM, Metal Body, Heavy Duty with Double Ball Bearing, generally Conforming to IS-2312, ISI Marked, suitable for operation on Single Phase, 240 Volts, AC, 50 Hz, including Louvers Shutter / Grill / Guard, BEE 5 Star Rated and of approved colour including connecting up with twin core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm and fixing in e and making good the disturbed surface complete all as specified and as directed.

5

-

-

... More
S & F Wall Mounted decorative type Air Circulator Fan, 400mm Sweep, Metal Body, Heavy duty with double ball bearing, low noise, Copper wound, 1400 RPM, Air Delivery not less than 270 Cum/min, wattage consumption not more than 190 watts, 230 Volts, AC, 50 Hz, Conforming to IS, complete with wall bracket and mounting accessories kit complete all as specified and as directed.

5

-

-

... More
M & L for Sub main wiring with 2 runs of single core 6 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawing through and including stove enamel steel Conduit 25 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type including One run of 6 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor complete all as specified and as directed. Note: 3 runs of 6 Sq.mm & one run of 25 mm dia stove enamelled Conduit will be measured as one unit.

45

-

-

... More
Supply and fixing LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp.complete all as specified and as directed.

10

-

-

... More
S & F Rotable LED Search light 200 W ,230 Volts, AC , high intensity and weather proof having high efficiency SS/G reflectors and range of 500m including connecting up with twin core twisted copper conductor cable .complete all as specified and as directed.

10

-

-

... More
Rerouting of existing XLPE cable of any size between 25 to 95 Sqmm by disconnecting all connections and refixing including necessary fittings complete all specified and as directed.

150

-

-

... More
Earthing complete with Galvanised Steel Earth Plate Electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of Plate not less than 1.50 m below normal ground level connected to 4 mm GI Wire [Earth Lead] and GI pipe 15 mm, Light Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the Plate by means of GI Bolts & Nuts complete all as per Electrical Plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. complete all as specified and as directed.

15

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.