Military Engineer Services Tender

To know what Andhra Pradesh government has posted about any AP etender, Bidassist helps us to get a one-stop platform where a registered bidder can have access to the details on each and every eprocurement tender. There is no need to provide the details on the AP E-procurement website i.e. https://www.apeprocurement.gov.in as BidAssist helps us find the specific etender we're looking for. BidAassist has collated each and every Eproc Andhra Pradesh Tender on its website.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date22 May 2024
Closing Date12 Jun 2024
Tender Amount₹ 48,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
S&F in repair Fuel filter with O ring suitable for 500 KVA DG set & make as per OEM complete all as specified and directed.

2

-

-

... More
S&F in repair Fuel filter with O ring suitable for 125-160 KVA set & make as per OEM complete all as specified and directed.

6

-

-

... More
S&F in repair Fuel filter with O ring suitable for 20-100 KVA set & make as per OEM complete all as specified and directed.

5

-

-

... More
S&F in repair Lub oil filter for 500 KVA DG set & make as per OEM complete all as specified and directed.

2

-

-

... More
S&F in repair Lub oil filter for 125-160 KVA DG Set & make as per OEM complete all as specified and directed.

4

-

-

... More
S&F in repair Lub oil filter for 20-100 KVA DG Set & make as per OEM complete all as specified and directed.

5

-

-

... More
S&F in repair Air cleaner filter ( inner and outer ) for 500 KVA DG set & make as per OEM complete all as specified and directed.

1

-

-

... More
S&F in repair Air cleaner filter ( inner and outer ) for 125-160 KVA DG set & make as per OEM complete all as specified and directed.

4

-

-

... More
S&F in repair Air cleaner filter ( inner and outer ) for 20-100 KVA DG set & make as per OEM complete all as specified and directed.

5

-

-

... More
S&F in repair Bypass filter for 500 KVA DG set & make as per OEM complete all as specified and directed.

1

-

-

... More
S&F in repair Bypass filter for 125-160 KVA DG set & make as per OEM complete all as specified and directed.

5

-

-

... More
S&F in repair V belt for 500 KVA DG set & make as per OEM complete all as specified and directed.

4

-

-

... More
S&F in repair V belt for 125-160 KVA DG set & make as per OEM complete all as specified and directed.

5

-

-

... More
S&F in repair V belt for 20-100 KVA DG set & make as per OEM complete all as specified and directed.

5

-

-

... More
S&F in repair Display control panel (LED Board) for 20 to 500 KVA DG set & make as per OEM complete all as specified and directed.

3

-

-

... More
S&F in repair Fuel actuator with O Ring for 20 to 500 KVA DG set & make as per OEM complete all as specified and directed.

2

-

-

... More
S&F in repair Key switch for 20 to 500 KVA DG set & make as per OEM complete all as specified and directed.

2

-

-

... More
S&F in repair coolant temperature sensor (coolent control safety) for 20 to 500 KVA DG set & make as per OEM complete all as specified and directed.

2

-

-

... More
S&F in repair AMF controller assy for auto/manual operation for 20 to 500 KVA DG set & make as per OEM complete all as specified and directed.

3

-

-

... More
S&F in repair Control assy main generator panel any type for 20 to 500 KVA DG set & make as per OEM complete all as specified and directed.

3

-

-

... More
S&F in repair Lube oil pressure sensor adaptor (oil control safety ) for 20 to 500 KVA DG set & make as per OEM complete all as specified and directed.

2

-

-

... More
S&F in repair Stop solenoid switch 12 Volts of make as per OEM complete all as specified and directed.

4

-

-

... More
S&F in repair Stop solenoid switch 24 Volts of make as per OEM complete all as specified and directed.

1

-

-

... More
Supply & Filling Coolant suitable for radiators & of make as per OEM complete all as specified and directed.

150

-

-

... More
S&F in repair Turbo charger for any capacity DG set & make as per OEM complete all as specified and directed.

2

-

-

... More
Supply & Filling engine oil multi grade 15W40 of following make or as per OEM all as specified and directed. Make : Servo / Bosch / Castrol / Valvoline / HPCL / ELF Oil

250

-

-

... More
S & F in repair Automatic Voltage Regulator suitable for DG set of any capacity and of make as per OEM complete all as specified and as directed.

2

-

-

... More
M & L for calibration of FIP and fuel injector from authorised dealer including petty repairs to make the FIP and injectors functional for DG set of capacity of 20-500 KVA complete all as specified and directed.

4

-

-

... More
Disconnecting the electric connection of Alternator of capacity 20 to 500 KVA DG set, taking the accumalator and cleaning the core assembly through air blower, heat varnishing with insulating material complete all as specified and as directed.

5

-

-

... More
S & F in repair Lub Oil cooler plate suitable for DG set of any capacity and of make as per OEM complete all as specified and as directed.

2

-

-

... More
S & F in repair Lub Oil pressure gauge pipe of required standard size suitable for DG set of any capacity and of make as per OEM complete all as specified and as directed.

2

-

-

... More
S & F in repair Oil spray nozzle assembly suitable for DG set of any capacity and of make as per OEM complete all as specified and as directed.

10

-

-

... More
S&F in repair Main Bearing as per existing, suitable for DG set of 20 to 500 KVA capacity and of make as per OEM complete all as specified and as directed.

4

-

-

... More
S & F in repair Water temp switch suitable for DG set of any capacity and of make as per OEM complete all as specified and as directed.

2

-

-

... More
S & F in repair Magnetic Pick Up Unit ( MPU) suitable for DG set of any capacity and of make as per OEM complete all as specified and as directed.

1

-

-

... More
S & F in repair water pump suitable for DG set of any capacity and of make as per OEM complete all as specified and as directed.

1

-

-

... More
S & F in repair Lub Oil pump high discharge of required standard size suitable for DG set of any capacity and of make as per OEM complete all as specified and as directed.

2

-

-

... More
S & F in repair field coil assembly suitable for 20-500 KVA DG set and of make as per OEM complete all as specified and as directed.

2

-

-

... More
S & F in repair Eye bolt suitable for 20-500 KVA DG set and of make as per OEM complete all as specified and as directed.

3

-

-

... More
S & F in repair fan key suitable for 20-500 KVA DG set and of make as per OEM complete all as specified and as directed.

2

-

-

... More
S & F in repair fan assembly suitable for 20-100 KVA DG set and of make as per OEM complete all as specified and as directed.

2

-

-

... More
S & F in repair fan assembly suitable for 125-160 KVA DG set and of make as per OEM complete all as specified and as directed.

2

-

-

... More
S & F in repair fan assembly suitable for 500 KVA DG set and of make as per OEM complete all as specified and as directed.

1

-

-

... More
S & F in repair fan suitable for 20-100 KVA DG set and of make as per OEM complete all as specified and as directed.

2

-

-

... More
S & F in repair fan suitable for 125-160 KVA DG set and of make as per OEM complete all as specified and as directed.

2

-

-

... More
S & F in repair fan suitable for 500 KVA DG set and of make as per OEM complete all as specified and as directed.

1

-

-

... More
S & F in repair Circlip suitable for 20-100 KVA DG set and of make as per OEM complete all as specified and as directed.

2

-

-

... More
S & F in repair Circlip suitable for 125 to160 KVA DG set and of make as per OEM complete all as specified and as directed.

2

-

-

... More
S & F in repair Circlip suitable for 500 KVA DG set and of make as per OEM complete all as specified and as directed.

1

-

-

... More
S & F in repair Brush holder spindle suitable for 20-100 KVA DG set and of make as per OEM complete all as specified and as directed.

2

-

-

... More
S & F in repair Brush holder spindle suitable for 125 to160 KVA DG set and of make as per OEM complete all as specified and as directed.

2

-

-

... More
S & F in repair Brush holder spindle suitable for 500 KVA DG set and of make as per OEM complete all as specified and as directed.

1

-

-

... More
S & F in repair NDE bearing cap suitable for 20 to100 KVA DG set and of make as per OEM complete all as specified and as directed.

2

-

-

... More
S & F in repair NDE bearing cap suitable for 125 to160 KVA DG set and of make as per OEM complete all as specified and as directed.

2

-

-

... More
S & F in repair NDE bearing cap suitable for 500 KVA DG set and of make as per OEM complete all as specified and as directed.

1

-

-

... More
S & F in repair Slipring assembly suitable for 20 to 100 KVA DG set and of make as per OEM complete all as specified and as directed.

1

-

-

... More
S & F in repair Slipring assembly suitable for 125 to 160 KVA DG set and of make as per OEM complete all as specified and as directed.

2

-

-

... More
S & F in repair Slipring assembly suitable for 500 KVA DG set and of make as per OEM complete all as specified and as directed.

1

-

-

... More
S & F in repair Exicitation (CX) unit suitable for 20 to 100 KVA DG set and of make as per OEM complete all as specified and as directed.

2

-

-

... More
S & F in repair Exicitation (CX) unit suitable for 125 to 160 KVA DG set and of make as per OEM complete all as specified and as directed.

1

-

-

... More
S & F in repair Exicitation (CX) unit suitable for 500 KVA DG set and of make as per OEM complete all as specified and as directed.

1

-

-

... More
S & F in repair Battery terminal made with brass suitable for 12/24 volt battery and of make as per OEM complete all as specified and directed.

4

-

-

... More
S & F in repair 12 volt, 180 AH battery complete all as specified and directed. Make:- Exide / Luminous / Nicco / AMCO / Amara Raja

5

-

-

... More
Material and labour for cleaning external surface of DG set of any capacity and make with cleaning agent including cleaning of radiators coil with with mild acid (or caustic soda) and cleaning of fuel tank etc complete all as specified and as directed.

7

-

-

... More
S & F in repair self starter 24 volt DC suitable for DG set of any capacity and of make as per OEM complete all as specified and as directed

1

-

-

... More
S & F in repair self starter 12 volt DC suitable for DG set of any capacity and of make as per OEM complete all as specified and as directed

3

-

-

... More
M&L for taking down, transporting, dismantling, repairing and servicing of self starter 12/24 volt DC at authorized service centre of OEM including assembling, bringing back, installing, commissioning and testing the same complete all as specified and as directed.

3

-

-

... More
M & L for maintanence and servicing of AMF panel including replacing unserviceable items, testing and replacing unserviceable wiring connection in panel for automatic operation through relay, contactor, timer, sensor etc all as directed. Note:- Cost of M&L for replacing spare parts mentioned here-in-below under relevant items shall not considered to be included in this item.

5

-

-

... More
S&F in repair multifunction meter, digital type (displaying A, V, PF etc.) complete all as specified and as directed. Make:- Elmeasure / L&T / Schneider / HPL / SOCOMEC

1

-

-

... More
S&F in repair phase indicator lamps (Red, Yellow and blue) suitable for AMF Panel complete all as specified and directed. Make:- L&T / Siemens / GE / RR Micro / BCH / Schneider

5

-

-

... More
S&F in repair three pole power contractor type AC3, 250 A with Aux contracts 2 Nos, 2 NC suitable for AMF panel complete all as specified and directed. Make: L&T / Indoasian / GE / BCH / HPL / C&S / ABB / Siemens

2

-

-

... More
S&F in repair three pole power contractor type AC3, 300 A with Aux contracts 2 Nos, 2 NC suitable for AMF panel complete all as specified and directed. Make: L&T / Indoasian / GE / BCH / HPL / C&S / ABB / Siemens

2

-

-

... More
S&F in repair AC Control contactor - M00AC - 15 4A at 415 Volt suitable for AMF panel complete all as specified and directed. Make: L&T / Indoasian / GE / BCH / HPL / C&S / ABB / Siemens

2

-

-

... More
S&F in repair DC control contactor M00DC 15 4A at 415 Volt suitable for AMF panel complete all as specified and directed. Make: L&T / Indoasian / GE / BCH / HPL / C&S / ABB / Siemens

2

-

-

... More
S&F in repair LED street light fitting of capacity 60 watt, IP-66 (minimum), integrated type with high efficiency electronic driver, SPD of capaciity 10 KV, 5700 K pressure die cast aluminium housing with toughened glass cover, internally prewired and including electrically connecting complete all as specified and as directed. Make:- Signify Innovations India Ltd (Formerly Phillips) / Havells / Crompton / Bajaj Note:- Supply of new GI Pipe bracket if required shall be measured and paid separately under relevant item.

50

-

-

... More
All as per serial Item No. 78.00 above but LED street light fitting of capacity 100 W

40

-

-

... More
S&F in repair LED flood light fitting of capacity 120 watt, IP-66 (minimum) with luminous efficacy 100 Lumen/watt (minimum), SPD of capaciity 10 KV, 5700K, pressure die cast aluminium housing, toughened glass cover, internally prewired and including electrically connecting complete all as specified and as directed. Make:- Signify Innovations India Ltd (Formerly Phillips) / Havells / Crompton / Bajaj

30

-

-

... More
All as per serial Item No. 80.00 above but LED flood light fitting of capacity 200 W

10

-

-

... More
S&F in repair bracket suitable for street light made out of GI pipe light grade of 40 mm bore & 1.50 mtr length (minimum), bend to shape including 2 pairs of MS flat iron clamps made out of 40 x 5 mm MS flat, nuts, bolts & washers etc, & painting the bracket with two coat of aluminium paint over a coat of red oxide primer complete all as specified and directed. Make of Pipe :- Tata / Jindal Steel / Surya Roshni Ltd. / Bhushan Power & Steel Ltd. / M/s APL Apollo Tubes Ltd

30

-

-

... More
M&L cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections and including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and including preparation of surfaces and applying two coats of aluminium paint over a coat of primer and dismantling complete all as specified and directed. Make of paint : Jotun India Pvt Ltd / Asian Paints / Berger / Jenson & Nicholson Paints Ltd / Shalimar Paints Ltd

0.5

-

-

... More
S&F in repair PVC insulated 3 core multistranded sheathed cable with 1.5 Sqmm copper conductor for connection of street / security light etc, including PVC conduit of suitable size and medium grade for cable protection complete all as specified and directed. Make:- Havells / KEI / Polycab / RR Kabel Ltd. / HPL

800

-

-

... More
S&F in repair 1 x 9 / 10 watt LED bollard light fitting, inverted conical shape, opal acrylic diffuser, IP-65, including hot dip galvanized pole, driver, all fixing arrangement etc. including electrically connecting complete all as specified and directed. Make:- Signify Innovations India Ltd (Formerly Phillips) / Havells / Crompton / Bajaj

15

-

-

... More
S&F in repair 35 watt LED post top lantern with polycarbonate opal diffuser, pressure die cast aluminium housing, IP-65 (minimum), high efficient constant current electronic driver including electrically connecting complete all as specified and directed. Make :- Signify Innovations India Ltd (Formerly Phillips) / Havells / Crompton / Bajaj

10

-

-

... More
Supply & laying LT XLPE insulated, armoured heavy duty electric cable with alumimium conductor, 1100 volts grade, cross sectional area 25 Sqmm x 4 Core, laid in trenches / duct / on pole including taking down existing cablecomplete all as specified and directed. Make :- Havells / KEI / Polycab / Gloster / Finolex

500

-

-

... More
All as per Sl Item No 87.00 above but 50 Sqmm x 3.5 core

100

-

-

... More
Excavation in trenches, not exc 1.5 m wide and not exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, laying cable etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out all excavated material in soft / loose soil complete all as specified and directed.

137

-

-

... More
Returning, filling in and including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and as directed.

73

-

-

... More
Removing of excavated surplus soil to a distance n. exc 50 m and depositing where directed at a level n. exc. 1.5 m above the starting point complete all as specified and directed.

64

-

-

... More
M&L sand cushioning with clean and dry sand in trenches for protection of UG cable and including punning down complete all as specified and directed. Note:- Punned thickness shall only be measured and paid.

43

-

-

... More
Supply & laying sub class 'B', class designation 75 bricks of old size, laid along alignment of cable as protection to cable in trenches complete all as specified and directed.

4500

-

-

... More
S&F in repair steel tubular swaged poles conforming to IS-2713, complete with cast iron base plate, finial taper plug, bolts, nuts & screws, type 410 SP-31 (9 m long) and including painting with two coat of aluminium paint over a coat of primer on exposed surfaces and black bituminous paint on steel surface embeded in concrete and 05 Nos band / strips with black and yellow synthetic enamel paint alternatively, 30 cm wide each at a distance of 30 cm from top of plinth block and numbering of poles complete all as specified and directed. Note:- Excavation, earth work and PCC work will be measured and paid for separately under respective items. Make of Pole:- Calcutta Poles & Tubes / Skipper Limited / Jindal Steel / National tubing Co / Bombay tube & Store Make of paint :- Jotun India Pvt Ltd / Asian Paints / Berger / Jenson & Nicholson Paints Ltd / Shalimar Paints Ltd

8

-

-

... More
M&L PCC 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) as in foundation, filling and mass concrete including demolition of old concrete complete all as specified and directed.

4.8

-

-

... More
M&L plain cement concrete 1:2:4 type B1, (using 20 mm graded crushed stone aggregate) as in copings, benching and the like etc. including necessary formwork & demolition of old concrete complete all as specified and directed.

0.8

-

-

... More
Boring holes horizontally under road, manually, in soft / loose soil, without cutting / disturbing the existing road surface, suitable for inserting pipe of n exc. 100 mm bore at a depth 0.75 m to 1.0 m from road surface for passing of UG cable, getting out and disposal of soil to a distance not exceeding 50 m complete all as specified and as directed. Note:- GI Pipe shall be measured and paid separately.

48

-

-

... More
S&F in repair 50 mm bore galvanised steel tubing, medium grade with necessary fittings, laid under road crossing, for cable protection complete all as specified and directed. Make - Tata / Jindal Steel / Surya Roshni Ltd. / Bhushan Power & Steel Ltd. / M/s APL Apollo Tubes Ltd

48

-

-

... More
M&L for cable route indicator for LT UG cable, 1100 Volt grade made out of 4mm thick MS sheet in round shape of dia not less than 200mm, embossed with LT Cable on it, bolted with 2 nut of suitable size at top of 40 x 6 mm MS flat iron of length not less than 1 meter, complete metal surfaces painted with 2 coats of synthetic enamel paint over a coat of primer & bottom of flat iron embedded in PCC 1:3:6 type C2 of size 200mm x 200mm x 500mm (400mm below ground level an 100mm above ground level), exposed surface of concrete painted with 3 coats of white wash including necessary earth work complete all as specified and directed.

10

-

-

... More
Taking down existing loop in loop out junction box, disconnecting the cable connections and refixing the same loop in loop out junction box with new cable connections including providing new set of aluminium lugs / thimbles of size 10 to 35 sqmm (as reqd) for 3.5/4 core existing LT cable of any type, necessary insulation with tape, clamps for fixing of cables, fittings and fixtures, nut bolts etc complete all as specified and directed.

60

-

-

... More
M&L for disconnecting electrical connection of defective / burnt out UG LT cable of any size 2 to 4 core from main switch / DB / Junction boxe / LT Panels, excavating, taking out the required length of existing cable from loop, cutting the defective portion of cable old termination at end, providing new aluminium thimbles / lugs of suitable size and reconnecting the same with existing location and refilling of cable trench with existing sand and bricks complete all as specified and as directed. Note :- (i) The rate quoted shall deemed to include cost of necessary earth work, matching the disturbed surfaces as per existing. (ii) Additional length of cable or joint required shall be measured and paid seperately

5

-

-

... More
S&F in repair weather proof cable junction box of size not less than 210 mm x 310 mm x 116 mm with terminals, IP 66 (minimum), suitable for outdoor installation, suitable for 10 to 25 sqmm cable, including 01 No 5/6 Amp MCB, 100 Amp rated 3 pole connector, fixing arrangement with MS flat of size 25 x 3 mm with necessary nuts, bolt and washers complete all as specified and directed. Make :- Hensel / Sintex Industries Ltd. / C&S electric Ltd. / National

32

-

-

... More
M&L preparation of old painted surface of existing 9 m long old steel poles with connected cross arms, cable protection pipes, clamps, street light brackets etc, and including applying one coat of aluminium paint on complete height of the pole and applying one coat of synthetic enamel paint upto 1.50 m height (05 Nos band / strips with black and yellow strips alternatively, 30 cm wide each at a distance of 30 cm) from top of of coping with multi colour strips as per the colour code, writing pole details & applying one coat of white wash on pole coping complete all as specified and directed. Make of paint :- Jotun India Pvt Ltd / Asian Paints / Berger / Jenson & Nicholson Paints Ltd / Shalimar Paints Ltd

450

-

-

... More
S & F in repair powered by inbuilt, isolated electronic LED driver (SMPS based constant current supply) suitable for 120-200 watt LED street lights / flood lights / Post top lantern / Bollard light fittings, site selectable with lower THD, Output Open / Short Circuit protection, Phase to Phase protection, Over Voltage protection, Surge Voltage protection complete all as specified and directed.

25

-

-

... More
All as per Sl Item No 104.00 above but suitable for 45 to 100 watt LED.

25

-

-

... More
Supply only surge protection device of capacity 10 KV & make as per existing, suitable for street light / flood light / post top lantern complete all as specified and directed.

30

-

-

... More
M&L in repair for wiring from LED panel to driver for 120-200 W LED fittings as per existing complete all as specified and directed.

10

-

-

... More
All as per Sl Item No 107.00 above but suitable for 45 to 100 watt LED.

10

-

-

... More
M&L earthing complete with galvanised steel earth plate electrode of size 600 x 600 x 6 mm thick buried directly in ground in vertical position (earth pit not less than 2.25 m deep below the normal ground level) with top edge of the earth plate not less than 1.5 m below normal ground level, connected to earth lead of galvanised iron strip 32 x 6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel, all as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point including dismantling old earthing complete all as specified and directed. Note:- The unit rate shall also include for earth work in any type of soil, PCC 1:3:6 type C1 chamber, RCC 1:1.5:3, type A1 cover slab, 50 mm thick reinforced with 8 mm dia TMT bar @ 140 mm C/C both ways, 10 mm dia plain bar lifting handle embedded in cover slab, Main earthing lead from earth electrode to test point upto 7.5 m length, 20 mm bore medium grade GI watering pipe, 40 mm bore GI medium grade earth lead protection pipe, funnel, wire mesh, copper lugs, charcoal and common salt in alternate layer etc.

7

-

-

... More
S&F in repairs 12 KW, three phase Nature Switch (using Infrared Sensor technology) based automatic street light timer switch for automatic switching on / off street light based on lux level of nature light (Required Illuminance Level for Switching ON is ≤ 60 Lux and for Switching OFF ≥ 10 Lux). The Sensor should also have part night operation facility of min. 4 hrs to max 12 hrs, consisting of sensor, overload protection fuse gear, 3 Nos contactor, 3 nos Incoming MCBs & 3 nos. Outgoing MCBs of 32-40 Amps each and Circuit wiring (Copper) of min.10 sqmm, terminal blocks for cable entry & control unit enclosed in pole / wall mountable enclosure made out of rust proof, Electric shock proof, termite proof thermoplastic polycarbonate Enclosure (with HINGED LID) conforming to IP66 protection class 2 , complete all as specified and as directed. Make:- Havells / GE / Kakatiya energy system Pvt Ltd / Indo Asian

3

-

-

... More
S&F in repair 4 pole connector 440V AC complete all as specified and as directed.

30

-

-

... More
S&F MCCB 4 pole 40 to 63 Amp, breaking capacity 16 kA, Ics = 100% Icu, thermal magnetic release type with adjustable overload setting (0.8-1.0 ln), adjustable short circuit setting (6-10 lr) including necessary modification in the panel & taking down existing MCCB complete all as specified and as directed. Make :- L&T / Havells / Panasonic / Hager / ABB / Legrand / Indo Asian / HPL

3

-

-

... More
M&L for complete leak testing of indoor and outdoor units of central AC plant of capacity 48 TR, complete refrigerant pipe with Nitrogen gas, locating the leaks, rectify the leak by brazing / welding and pressure testing the complete system all as specified and as directed by Engineer-in-Charge.

3

-

-

... More
Supply and charge refrigerant gas R407 C all as directed by Engineer-in-Charge. Make: Mafron/ Freon/ Floron / Refron / National

60

-

-

... More
S&F in repair 3 pole contactor of capacity 40 Amp capacity suitable for central AC plant of capacity 48 TR complete all as specified and directed. Make: L&T / Havells / Indoasian / GE / BCH / HPL / C&S / ABB / Siemens

2

-

-

... More
S&F in repair EWT/LWT sensor suitable for central AC plant of capacity 48 TR complete all as specified and directed.

2

-

-

... More
M&L for dismantling defective induction motor of 7.5 HP capacity & any make, 415 V, of any duty or any class of insulation from the bed duly coupled with pump, transporting to work shop, removing burnt out winding from stator, rotor and re-winding the same with existing gauge super enameled copper wire of approved make and supply & replacing driven end and non driven end bearings, insulation materials, varnishing, heating, reassembling, testing and commissioning complete all as specified and directed. Notes :- Motor removed for rewinding shall be overhauled completely and quoted rate shall be deemed to be inclusive for the same.

1

-

-

... More
Dismantling pump/motor set 7.5 HP and disconnecting water and electric connection removing shaft from impeller and dismantling, grinding, polishing to shaft & suction cover and replacing , Gun metal bushes for shaft , Key for shaft , Graphite packing , water slinger , Gland bush, coupler etc fixing gland rope, greasing and fixing same shaft and impeller and reassembling properly testing all as specified

2

-

-

... More
Dismantling pump/motor set of capacity 8000 CFM and disconnecting water and electric connection removing shaft from impeller and dismantling, grinding, polishing to shaft & suction cover and replacing, Gun metal bushes for shaft, Key for shaft, Graphite packing, water slinger, Gland bush, coupler etc fixing gland rope, greasing and fixing same shaft and impeller and reassembling properly testing all as specified.

1

-

-

... More
All as per Sl Item No 119.00 above but for capacity 37500 CFM

1

-

-

... More
M&L for removing the wornout duct insulation carefully, cleaning / preparation of duct surface by scrapping carefully with wire brush etc. to make the surface completely free of millscale, dirt, dust, grease and other foreign materials, providing new duct insulation, not less than 13mm thick with nitrile rubber insulation with aluminium film reflective surface including taking special care to ensure duct joints sealed against any leakage complete all as specified and directed.

10

-

-

... More
M&L for taking down 48 TR Chiller package unit direct expansion type outdoor including dismantling the units carefully, chemical cleaning of compressor, condenser tube and control piping, with appropriate cleaning agents, flushing through proper air flow across the coils to improve the cooling efficiency, reassembling & re-installing the units in their original position including replacing defective spare parts and testing & commissioning complete all as directed by Engr-in-Charge. Note : Minor spares required other than spare parts under item No 123 to 127 of BOQ shall considered to be included in the unit rate quoted of this item.

4

-

-

... More
S & F in repair Scroll compressor suitable for AC plant of capacity 48 TR (Bluestar, Model - XAC2YS-048AR2) and of make as per OEM complete all as specified and directed.

1

-

-

... More
S & F in repair Filter Drier suitable for AC plant of capacity 48 TR (Bluestar, Model - XAC2YS-048AR2) and of make as per OEM complete all as specified and directed.

3

-

-

... More
S & F in repair Expansion Valve suitable for AC plant of capacity 48 TR (Bluestar, Model - XAC2YS-048AR2) and of make as per OEM complete all as specified and directed.

2

-

-

... More
S & F in repair Pressure Controller suitable for AC plant of capacity 48 TR (Bluestar, Model - XAC2YS-048AR2) and of make as per OEM complete all as specified and directed.

2

-

-

... More
S & F in repair ODU Fan Motor-2 HP suitable for AC plant of capacity 48 TR (Bluestar, Model - XAC2YS-048AR2) and of make as per OEM complete all as specified and directed.

2

-

-

... More
M&L for complete leak testing of indoor and outdoor units of VRF type AC plant of capacity 28 HP X 2 + 26 HP X 1 (Make- Bluestar), complete refrigerant pipe with Nitrogen gas, locating the leaks, rectify the leak by brazing / welding and pressure testing the complete system all as specified and as directed by Engineer-in-Charge.

1

-

-

... More
All as per Sl Item No 128.00 above but for VRF AC plant of capacity 18 HP + 24 HP (Make- Bluestar)

1

-

-

... More
All as per Sl Item No 128.00 above but for VRF AC plant of capacity 14 HP + 24 HP (Make- Bluestar)

1

-

-

... More
Supply and charging R-410A Refrigerant Gas complete all as specified and as directed. Make: Mafron/ Freon/ Floron / Refron

80

-

-

... More
S & F in repair outdoor fan motor DC 8 P, E class, 910 W suitable for VRF unit and of make as per OEM complete all as specified.

1

-

-

... More
S & F in repair programable circuit board suitable for VRF unit (Bluestar ) and of make as per OEM complete all as specified.

2

-

-

... More
S&F MCCB 3 pole 63 to 100 Amp, breaking capacity 36 kA, Ics = 100% Icu, thermal magnetic release type with adjustable overload setting (0.8-1.0 ln), adjustable short circuit setting (6-10 lr) including necessary modification in the panel & taking down existing MCCB complete all as specified and as directed. Make :- L&T / Havells / Panasonic / Hager / ABB / Legrand / Indo Asian / HPL

2

-

-

... More
S&F MCCB 4 pole 160 Amp, breaking capacity 36 kA, Ics = 100% Icu, thermal magnetic release type with adjustable overload setting (0.8-1.0 ln), adjustable short circuit setting (6-10 lr) including necessary modification in the panel & taking down existing MCCB complete all as specified and as directed. Make :- L&T / Havells / Panasonic / Hager / ABB / Legrand / Indo Asian / HPL

1

-

-

... More
S&F in repair butterfly valve 100mm bore, PN 1.6 with necessary rubber gasket, bolts, nuts and washer complete all as specified and as directed by Engineer-in-Charge. Make: Zoloto / L&T/ Audco / Leader

2

-

-

... More
S&F in repair butterfly valve 80mm bore, PN 1.6 with necessary rubber gasket, bolts, nuts and washer complete all as specified and as directed by Engineer-in-Charge. Make: Zoloto / L&T/ Audco / Leader

2

-

-

... More
S&F in repair pressure gauge with syphon & valve complete all as specified and directed

2

-

-

... More
S&F in repair thermometer with valve complete all as specified and directed

1

-

-

... More
M&L for opening the outer sheets of Air Handling Unit (AHU) to access cooling coil, washing / cleaning of cooling coil externally with mild acid (or caustic soda hot water solution) followed by water jet including cleaning / washing of air filter and re-fixing, complete all as specified and directed by GE.

2

-

-

... More
S & F in repair Communication module suitable for 48 TR chiller unit (Bluestar) and of make as per OEM complete all as specified and directed.

1

-

-

... More
S & F in repair AC/DC converter suitable for 48 TR chiller unit (Bluestar) and of make as per OEM complete all as specified and directed.

2

-

-

... More
S & F in repair condenser water temperature sensor suitable for 48 TR chiller unit (Bluestar) and of make as per OEM complete all as specified and directed.

2

-

-

... More
S & F in repair discharge pressure sensor suitable for 48 TR chiller unit (Bluestar) and of make as per OEM complete all as specified and directed.

1

-

-

... More
S&F in repair of single phase preventor 40V AC asymmetry including connecting accessories complete all as specified. Make :- L&T / Havells / Panasonic / Hager / ABB / Legrand / Indo Asian

2

-

-

... More
S&F in repair Intermediate relay 220V AC including connecting accessories complete all as specified. Make :- L&T / Havells / Panasonic / Hager / ABB / Legrand / Indo Asian

2

-

-

... More
S&F in repair microprocessor controller cord module for chilled water system suitable for 48 TR chiller unit (Bluestar) and of make as per OEM complete all as specified and directed.

1

-

-

... More
S&F in repair liquid level sensor suitable for 48 TR chiller unit and of make as per OEM complete all as specified and directed.

1

-

-

... More
S&F in repair Solenoid Coil suitable for 48 TR chiller unit and of make as per OEM complete all as specified and directed.

3

-

-

... More
S&F in repair Oil Filter suitable for 48 TR chiller unit and of make as per OEM complete all as specified and directed.

2

-

-

... More
S&F in repair DP switch suitable for 48 TR chiller unit and of make as per OEM complete all as specified and directed.

2

-

-

... More
S&F in repair PRE filter 10 micron, a layer of non woven media stitched along with layer of GI wire mesh on the downstream side to obtain required filtration and efficiency, pleats separated by spacers for maximum air flow of size 610x610x50mm complete all as specified and directed.

8

-

-

... More
S&F in repair Suction pressure sensor suitable for 48 TR chiller unit and of make as per OEM complete all as specified and directed.

1

-

-

... More
S&F in repair of V belt A/B Series as per site requirement complete all as specified and directed. Make : Fenner/Dunlop

5

-

-

... More
S&F in repair of Timer 3-30 Seconds complete all as specified and directed. Make :- L&T / Legrand / Siemens / ABB / Schnieder / Havells

4

-

-

... More
S&F in repair of overload relay type MN-2 range 24-40 A complete all as specified and directed. Make :- L&T / Legrand / Siemens / ABB / Schnieder / Havells

4

-

-

... More
S&F in repair digital ammeter 0 - 500 Amp, 3 phase, accuracy class 1 with LED display & in-built selector switch complete all as specified and directed. Make:- Havells India Ltd. / HPL India Ltd. / L&T / AE / Schneider / BCH

2

-

-

... More
S&F in repair digital voltmeter 0-520 volts (P-P), 3 phase, accuracy class 1 with LED display & in-built selector switch complete all as specified and directed. Make :- Havells India Ltd. / HPL India Ltd. / L&T / AE / Schneider / BCH

3

-

-

... More
S&F in repair on-load change over switch 400 Amp capacity, 3 phase, 415 volts suitable for panel mounting complete all as specified and directed. Make:- L&T / Legrand / ABB / Siemens / Schnieder / Havells India Ltd. / Indo Asian

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.