Military Engineer Services Tender

To know what Andhra Pradesh government has posted about any AP etender, Bidassist helps us to get a one-stop platform where a registered bidder can have access to the details on each and every eprocurement tender. There is no need to provide the details on the AP E-procurement website i.e. https://www.apeprocurement.gov.in as BidAssist helps us find the specific etender we're looking for. BidAassist has collated each and every Eproc Andhra Pradesh Tender on its website.

Military Engineer Services - MES Tender

Works
Civil And Construction
Civil Works Others
Eprocure
Opening Date13 Jan 2025
Closing Soon11 Feb 2025
Tender Amount₹ 48,80,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc., and disposal of unserviceable materials, debris and rubbish as directed by the Engineer in Charge.

30

-

-

... More
M&L walling of random rubble , uncoursed , well bonded , bedded and solidly heared built in cm 1:6 all as specified and directed.

30

-

-

... More
Extra over stone walling of 40 mm thick for hammer dressing to face stone and dressing of face beds and joints as specified of random rubble walling uncoursed or brought upto course all as specified and dircted.

150

-

-

... More
Racking out joints / pointing torandom rubble or polygonal rubble uncoursed or brought upto courses in cement mortar all as specified and directed.

15

-

-

... More
Excavating in post holes (or similar holes) each n exc 0.5 cum getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance n exc 50m and making good surface and getting out in hard/dense soil.

576

-

-

... More
Plain cement concrete type D2, 1:4 :8 (40mm graded stone aggregate) in foundations, fillings and mass concrete.

31.1

-

-

... More
Plain cement concrete type D2, 1:2 :4 (40mm graded stone aggregate) in foundations, fillings and mass concrete.

82.12

-

-

... More
Providing Precast RCC (1:2:4) type B1 using (20 mm graded aggregate ) in precast post , fencing post, straining or terminal post , struts etc for fencing average sectional area n exc 250 sq.cm with or without chamferd angles and flat , splayed and rounded or mitred tops all as specified and directed. columns, pillars , piers, post and struts etc complete all as specified and directed.

57.84

-

-

... More
M & L for Mild steel TMT bars 5 mm to 10 mm dia., cut to length, bent to shape required, in stirrups, spacers and binders and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips.

4641.4

-

-

... More
M & L for form work to sides of pillars, posts, struts, piers, columns and stanchions square, or rectangular with rough finished surfaces of concrete complete all as specified 7 directed.

1223.42

-

-

... More
S& F Galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2 mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts including securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins etc as directed.

299

-

-

... More
M&L Preparing newly plastered or unplastered wall surfaces and applying two coats of cement base paint over one coat of white wash complete all as specified and as directed.

1373.42

-

-

... More
M & L for Plain cement concrete type B0, (1:2:4) (using 12.5 mm graded stone aggregate) cast in situ in cills and other similar bands, plinth courses, parapets, copings, hold fast, bed plates and the like including use and waste of form work, weathering, slightly rounded or chamfered angles and throating as required.

1.2

-

-

... More
SCHEDULE 'A' PART-II: E/M WORKS

-

-

-

... More
S & F voltage stablizer for automatic operation, sigle phase naturally air cooled indoor type & designed for input varitation between 170 volt to 250 volt with output voltage stabilized at 230 volt with accuracy of ( + / - ) 2.5% and of capacity 3.0 KVA complete all as specified and directed.

2

-

-

... More
S & F voltage stablizer for automatic operation, sigle phase naturally air cooled indoor type & designed for input varitation between 170 volt to 250 volt with output voltage stabilized at 230 volt with accuracy of ( + / - ) 2.5% and of capacity 4.0 KVA complete all as specified and directed.

7

-

-

... More
Supply, install, testing and commissioning of Hi wall Split Air conditioner, BEE 5 star rated, with indoor / outdoor units with cordless remote control unit in built air ioniser and plasma filter for better indoor air quality with latest inverter technology having eco friendly refrigerent gas, copper condenser coil, EER 3.2 of capacity 1.5 TR complete all as specified and directed .[Make: BLUE STAR/ HITACHI/ DAIKIN / CARRIER / LG] (Note :- 1. The rate consider deemed to include of bracket for fixing of indoor and outdoor unit in wall of any height as directed by Engr-in charge. 2. The copper tube of suitable size and length (for each ACs), Drain pipe, cables with plug top are included in quoted rate. 3. Provision of passing of indoor/outdoor pipe from wall / core cutting in any type of wall are included with quoted rate.)

2

-

-

... More
S & F Modular Single pole and neutral enclosure with a two pin and earth plug and socket complete with one SPN MCB of 20A rating complete all as specified and as directed.

11

-

-

... More
M&L for sub main wiring with two run of 4.0 Sq. mm PVC un-sheathed, copper conductor cable, 1100 Volt, and one run of copper earth wire 4.0Sq mm drawn through PVC concealed conduict of 25 mm dia, complete all as specified. Note: Copper conductor 2 run and one run of copper earth wire along with PVC concealed conduict shall be measured as one length & Cutting of chases/walls and making good the disturbed surface are included in the rate.

180

-

-

... More
Supply and fixing of MCB 40 to 63Amp, 240 Volt, SPN, breaking capacity 10 KA 'C' series, , complete all as specified

2

-

-

... More
Supply and fixing of MCB 6 to 32Amp, 240 Volt, SP, breaking capacity 10 KA 'C' series, complete all as specified

13

-

-

... More
Supply and fixing of Factory made sheet metal enclosure for DBs double door (Fixed flush to the wall),SPN, 240 volt, 8 Way, IP-42 protection with 200 Amp rated bus bar and 1.5 Sq. mm copper PVC sheathed cable for earth continuity and suitable for having MCB's complete all as specified.

1

-

-

... More
Supply, install, testing and commissioning of Vertical / Tower type 2.5 TR Air conditioner complete set including suitable stand for out door unit, drain system with 20mm dia PVC conduit upto ground level including refrigerant gas charging , copper tubing , remote and remote stand and making good disturbed surface to mach with original status complete all as specified and directed

6

-

-

... More
Supply, install, testing and commissioning of Hi wall split type 1.5 TR Air conditioner complete set including suitable stand for out door unit, drain system with 20mm dia PVC conduit upto ground level including refrigerant gas charging , copper tubing , remote and remote stand and making good disturbed surface to mach with original status complete all as specified and directed

3

-

-

... More
S & F voltage stablizer for automatic operation, sigle phase naturally air cooled indoor type & designed for input varitation between 170 volt to 250 volt with output voltage stabilized at 230 volt with accuracy of ( + / - ) 2.5% and of capacity 5.0 KVA complete all as specified and directed.

6

-

-

... More
M & L for sub main wiring with four run of 10.0 Sq. mm PVC un-sheathed, copper conductor cable, 1100 Volt, and one run of copper earth wire 10.0 Sq mm drawn through PVC concealed conduit of 25 mm die, complete all as specified and specified. Note: Copper conductor 4 run and one run of copper earth wire along with PVC concealed conduict shall be measured as one length & Cutting of chases/walls and making good the disturbed surface are included in the rate.

100

-

-

... More
Supply and fixing of Factory made sheet metal enclosure for VTPN DB 4 way (Fixed flush to the wall), with provision of MCCB 100 Amps,16 KA, 415 volt, IP-43 protection with 200 Amp rated bus bar and 6.0 Sq. mm copper PVC sheathed cable for earth continuity and suitable for having MCB's , complete all as specified.

1

-

-

... More
Supply and fixing of Factory made sheet metal enclosure for DBs double door (Fixed flush to the wall), TPN, 415 volt, 4 Way, IP-42 protection with 200 Amp rated bus bar and 1.5 Sq. mm copper PVC sheathed cable for earth continuity and suitable for having MCB’s , complete all as specified.

1

-

-

... More
Supply and fixing of MCB 40-63Amp, 415 Volt, TP, breaking capacity 10 KA 'C' series, , complete all as specified

4

-

-

... More
S & F Modular triple pole and neutral enclosure with a three pin and earth plug and socket complete with one TPN MCB of 32A rating complete all as specified and as directed.

2

-

-

... More
Supply laying and testing cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric power cables heavy duty 1100 volts grade with stranded aluminium conductor of size 35 sqmm 3.5 core complete all as specified and as directed.

250

-

-

... More
M&L Earthing complete with GI plate electrode 600x600x6mm thick, buried directly and preferably Each vertically in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 mtr below normal ground level, connected with galvanised earth lead wire 4.0mm dia as earth lead by means of bolts, nuts, check nuts and washers of copper all as shown in electrical plate No 5, connected to earthing with DBs all as specified and filling up with adequate Charcoal and Rock salt, including earth work and excavation in any type of soil, PCC 1:3:6 type Cl chamber & RCC 1:2:4 type B1 cover 40mm thick, with 8mm dia steel deformed (TMT bars) reinforcement at 150mm c/c both ways, 20mm dia GI medium grade pipe for watering , water funnel complete all as specified and testing on completion including taking down old

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.