Military Engineer Services Tender
To know what Andhra Pradesh government has posted about any AP etender, Bidassist helps us to get a one-stop platform where a registered bidder can have access to the details on each and every eprocurement tender. There is no need to provide the details on the AP E-procurement website i.e. https://www.apeprocurement.gov.in as BidAssist helps us find the specific etender we're looking for. BidAassist has collated each and every Eproc Andhra Pradesh Tender on its website.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date3 Jan 2025
Closing Date24 Jan 2025
Tender Amount₹ 40,70,000
Costs
EMD
₹ 81,400Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_691645_1Tender No
82697Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
Supply & replacement of buffer (For opening spring) for up to 800 A 11 KV VCB complete all as specified and directed.
4
-
-
... More
Supply & replacement of buffer (For closing Spring) for up to 800 A 11 KV VCB complete all as specified and directed.
4
-
-
... More
Supply & replacement of thermostat and space heater, 230V AC supply inside 11 KV HT VCB, cable chamber complete all as specified and directed.
12
-
-
... More
Supply & replacement of single (Red-Blue) phase bus bar spout suitable for up to 800 A11 KV panel complete all as specified and directed.
12
-
-
... More
Supply & replacement of single (Y) phase bus bar suitable spout for up to 800 Amps 11 KV panel complete all as specified and directed.
6
-
-
... More
Supply & replacement of drive beam suitable for up to 800A 11 KV VCB complete all as specified and directed.
2
-
-
... More
Supply & replacement of epoxy body suitable for up to 800 A 11 KV VCB complete all as specified and directed.
2
-
-
... More
Supply & replacement of CT Spout suitable for up to 800 A 11 KV panel complete all as specified and directed.
10
-
-
... More
Supply & replacement of CT's epoxy cast resin insulator with primary current 100A, 50A respectively as per feeder requirement,. Secondary current 1A or 5A, with dual core, dual ratio. protection core - Class 5P10 & Metering core - Class 1, 15 VA suitable for 11 KV panel complete all as specified and directed.
10
-
-
... More
Supply & replacement of busbar support insulator suitable for 11 KV panel with all necessary modifications at cable / busbar chambers complete all as specified and directed.
12
-
-
... More
M&L servicing for Schneider make 800 A, 11 KV, HWX VCBs for setting of 3 phase IED of any type / Make from 11KV HT panel, cleaning the contacts, IED configuration, Calibration & Testing of all the measuring & protection devices viz., CTs, Relays and Meters at site and including testing of all the trip functions of the relays after final current settings by simulating fault current by CT secondary injection test set , checking of current transformer, rectification of defects in control wiring for proper tripping of CB during actual system fault conduction through relay & tripping coil. Adjustment / setting to plug and time multiplier settings of IED to achieve the discrimination in tripping, tune / synchronies upstream breaker relay settings-installation of relay, testing & commissioning etc. proper programming of multifunctional meters and replacement of defective components & wiring with FRLSH multistrand PVC insulated copper conductor 1100 volts grade as per existing size of wire complete all as specified and directed.
Note : Servicing will be carried out through OEM.
12
-
-
... More
Supply & replacement of relay REL52016D, equivalent to Micom P127 Modle No P3U30-6AAA2BBAA complete all as specified and directed.
2
-
-
... More
Overhauling, maintenance, servicing, buffing / cleaning, electroplating of copper busbar in busbar chamber of each VCB panel and including connecting bus bar from CT to main bus bar & spout. servicing of support insulator by clean cloth and hot air blower / vacuum cleaner, checking for any loose contact, refixing of all nuts & bolts by stainless steel, refixing of all covers, replacement of defective bus spout complete all as specified and directed
10
-
-
... More
Note :- (i) Replacement of defective parts of the VCB shall be measured and paid separately.
(ii) Overhauling of VCBs include the following:- (Before & After)
(i) IR test (5KV)
(ii) Timing test. (Opening and Closing)
(iii) CRM test (CB close) (iii) The rate quoted shall be deemed to be include for necessary T&P, nuts, bolts , washers, gasket, insulation tape, HT sleeve, monoplast compound to put in to the VCBs and Panles in serviceable condition.
-
-
-
... More
Supply & replacement of REL52016D, equivalent to Micom P127 Model No P3U20-6AAA1ABAA complete all as specified and directed.
2
-
-
... More
M&L attending rectification of faults in 11 KV VCB electrical circuit with all necessary accessories, tools & tackles for restoring the power supply with minimum shutdown time complete all as specified and directed.
Note:- Required new components will be measured and paid separately under relevant items.
16
-
-
... More
M&L servicing of SF6 insulated outdoor type compact Ring main unit HT 630 Amps, 11KV, 50 Hz consisting of any no of Incoming and outgoing to transformers with PT chamber and line CT by removing both the sources of power supply feeding through connected HT cable. switching on interlocking mechanism with earth switch carefully, checking its cable ends; removing the body cover of RMU; opening its covers, moving and fixed contacts, repair of moving / fixed parts, repair of its drive mechanism, moving & fixed contact, refixing its body covers, refixing the RMU with both ends of cables; necessary testing and charging the RMU complete all as specified and directed.
Note: (i) Each RMU of any no of Incoming & Outgoing will be measured as for One Job.
(ii) The quoted rate is deemed to be incude for spray paint over the body of the RMU with existing colour.
5
-
-
... More
Supply & replacement of transformer HT terminal connector bushing boots of suitable length / size suitable for existing distribution transformers of any make/ size/ type/ capacity complete all as specified and directed
10
-
-
... More
M&L cable end jointing kit for 11 KV grade cable heat shinkable Indoor type joint complete with jointing material and accessories suitable for 3 core 120 sqmm to 185 sqmm size cable complete all as specified and directed.
2
-
-
... More
M&L cable end jointing kit for 11 KV grade cable heat shinkable indoor type joint complete with jointing material and accessories suitable for 3 core 240 sqmm to 300 sqmm size cable complete all as specified and directed.
2
-
-
... More
Supply & replacement of 11KV grade heat shrinkable bus bar Insulation sleave 75 / 30 for HT panels complete all as specified and directed.
30
-
-
... More
Supply & replacement of 11KV grade heat shrinkable bus bar Insulation Sleave 50/20 for HT panels complete all as specified and directed.
30
-
-
... More
M&L cable jointing kit for 11 KV grade cable for indoor termination heat shrink type joint with jointing material and accessories suitable for 3 core XLPE armoured Al conductor cable of size 120 to 185 sqmm complete all as specified and directed.
4
-
-
... More
M&L cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm complete all as specified and directed.
8
-
-
... More
M&L cable end jointing kit for 11 KV grade cable heat shinkable indoor type joint with jointing material and accessories suitable for 3 core 240 sqmm to 300 sqmm size cable complete all as specified and directed.
6
-
-
... More
M&L cable end jointing kit for 11 KV grade cable heat shinkable outdoor type joint with jointing material and accessories suitable for 3 core 120 sqmm to 185 sqmm size cable complete all as specified and directed.
4
-
-
... More
M&L cable end jointing kit for 11 KV grade cable heat shinkable outdoor type joint with jointing materials and accessories suitable for 3 core 240 sqmm to 300 sqmm size cable complete all as specified and directed.
4
-
-
... More
M&L cable straight through joint kit for 11 KV grade cable heat shinkable outdoor type joint with jointing material and accessories suitable for 3 core 240 sqmm to 400 Sqmm to size cable complete all as specified and directed.
2
-
-
... More
Supply and lay test of 3 core 120 sqmm, 11000 volts grade, earthed XLPE cable insulated screen PVC bedded galvanisized steel strip or wire armoured electric power cable (heavy duty) with strandard aluminium conductor and including taking down complete all as specified and directed. Note:- Earth work excavation sand cushioning and brick protection will be measured and paid separately under relevant items of this schedule.
30
-
-
... More
All as per Sl. item No. 31 above but 3 core 150 sqmm.
30
-
-
... More
All as per Sl. item No. 31 above but 3 core 185 sqmm.
40
-
-
... More
All as per Sl. item No. 31 above but 3 core 240 sqmm
30
-
-
... More
Excavation in trenches not exc.1.5m wide and not exceeding 1.5 m depth and getting out hard / dense soil and dense soll for laying of under ground cable and including taking out of cable, cable cover complete all as specified and directed.
9
-
-
... More
All as per Sl. item No. 35 above but soft / loose soil
50
-
-
... More
Returning and filling in soils and including spreading, levelling, watering and well ramming in layers each not exceeding 25 cm thick complete all as specified and directed.
40
-
-
... More
Removing excavated soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
19
-
-
... More
Supply and laying reinforced precast concrete cable cover class HV type 1, flat size 300 x 180 x 40 mm complete all as specified and directed.
361.11
-
-
... More
Supply and spread clean dry river sand as cable cushioning for protection of cable to be laid in trenches / transformer yard / two pole structure complete all as specified and directed.
Note: Punned thickness shall be measured.
7
-
-
... More
Servicing of 11 KV / 0.433 KV transformer up to 500 KVA by Opening the inspection cover / top cover, decanning of the transformer oil up to the required level for replacement of top gasket, stud leakage from the shell and replacement of gasket to avoid leakage of oil refilling back to existing oil into the transformer complete all as specified and directed.
Note:- Supply only HT / LT bush will be measured and paid separately under relevant item.
7
-
-
... More
All as per item No.41 above but 750 KVA to 1000 KVA capacity.
2
-
-
... More
Supply only of HT bushing including metal parts and washer for any make/ any model of plinth/ pole mounted transformer 100 to 300 KVA capacity complete all as specified and directed.
18
-
-
... More
All as per item No.43 above but 320 to 500 KVA capacity.
18
-
-
... More
All as per item No.43 above but LT bushing for 100 to 300 KVA capacity.
18
-
-
... More
All as per item No.43 above but LT bushing for 320 to 500 KVA capacity.
18
-
-
... More
Supply only LT rod / studs made of brass with nut and washers fittings etc as per size and shape of original for the following complete all as specified and directed:-
-
-
-
... More
100 to 500 KVA
18
-
-
... More
750 to 1000 KVA
18
-
-
... More
Supply only HT rod / studs made of brass with nut and washers fittings etc as per size and shape of original for the following complete all as specified and directed:--
-
-
-
... More
250 to 500 KVA
18
-
-
... More
750 to 1000 KVA
18
-
-
... More
Note for item Nos. 43 to 48 :- These items willebe replaced immediately during break down period and the work will be executed as directed by Engr-In-charge. Penaly for late response @ Rs.100 per item per day will be recovered in the RAR / FB.
-
-
-
... More
Supply only neoprene gasket for pole / plinth mounted transformer of any capacity of size 2 feet x 2 feet size complete all as specified and directed.
15
-
-
... More
Supply only transformer oil to fill in transformer plinth / pole mounted complete all as specified and directed.
600
-
-
... More
Dehydration and including filtration cleaning of transformer oil in transformer indoor / outdoor type at different location INS kalinga area by centrifusion / machine having minimum capacity 1000 to 30000 ltrs / hour to achieve dielectric strength not less than 50 KV and including testing of oil before and after dehydration and topping up transformer oil complete all as specified and directed. Note :- Transformer oil for topping up will be paid and separately under relevent items of this schedule.
12000
-
-
... More
Supply & replacement of ACSR jumper in HT/ LT Over Head line of existing size and including binding wire, nuts & bolts washers complete all as specified and directed.
Note:- This item shall be executed immediately as and when required basis.
10
-
-
... More
M&L spray painting of 1000 KVA transformer pole mounted / plinth mounted at site with synthetic enamel grey paint and including removing all dust & rust and paint complete all as specified and directed.
3
-
-
... More
All as per item No. 53 above but 750 KVA
2
-
-
... More
All as per item No. 53 above but 500 KVA
5
-
-
... More
All as per item No. 53 above but 315 to 350 KVA
5
-
-
... More
All as per item No. 53 above but 200 to 250 KVA
5
-
-
... More
All as per item No. 53 above but 150 to 160 KVA
2
-
-
... More
All as per item No. 53 above but 63 to 100 KVA
4
-
-
... More
All as per item No. 53 above but LT / HT panels / OCBs / ACBs / RMUs
150
-
-
... More
Removal of material from yard and depositing a side for 2 pole structure yard for filling of sand in yard and refilling the same duly cleaning from the foreign materials after laying sand layers complete all as specified and directed.
4
-
-
... More
All as per item No. 61 above but 4 pole structure yard
3
-
-
... More
Supply and spread 40 mm graded stone aggregate in structure yard of 2/4 pole complete all as specified and directed.
7
-
-
... More
Supply and spread 20 mm graded stone aggregate in structure yard of 2/4 pole complete all as specified and directed.
7
-
-
... More
Supply & replacement of lightning arresters expulsion type complete with all fittings transmission class, discharge capacity 65 Kilo amps suitable for 11000 Volts complete all as specified and directed.
3
-
-
... More
M&L detecting HT/LT UG cable faults located in any stretch / depth with sophisticated cable fault locator consisting of microprocessor based pre locator system HV Surge generator fault pin point surge wave receiver cable identification instrument cable tracer for exact locations of under groung cable routes complete all as specified and directed.
Note : The rate quoted is deemed to be includes rental charges for T&P like entire cable Fault locating Instrument, Charges for operator and transport etc.
5
-
-
... More
Supply & replacement of underground cable route indicator HT/LT made out of cast iron piece not less than 6 mm thick supported by 25 x 6 mm flat iron piece complete all as specified and directed.
45
-
-
... More
Supply & replacement of danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in singal red colour and fixed with MS clamps, bolts and Nuts of approved size for HT 25 X 20 cm size complete all as specified and directed.
10
-
-
... More
Supply & replacement of GOD Air Break switch for 2/4 pole structure (set of Three) horizontal / vertical type and including all fiting and fixture, painting as per existing complete all as specified and directed.
4
-
-
... More
Supply & replacement of silica jel for 100 KVA to 1000 KVA transformer complete all as specified and directed.
15
-
-
... More
Supply & replacement of breather assembly for 100 KVA to 1000 KVA transformer complete all as specified and directed.
6
-
-
... More
Jungle cleaning and including cutting the plants / bushes and trees not exc. 25 cm in grith up to authorised widths and thrown away the rubbish to a distance not exc. 50 M and proper cleaning of sub station, RMU, Four pole and two pole structure area complete all as specified and directed.
460
-
-
... More
Servicing of testing of CTs through Primary Injection of the HT breaker complete all as specified and directed.
4
-
-
... More
Supply and replacement of 12V 75 AH / 100 AH, DC, VRLA cell and arrange properly with connecting leads inside battery rack suitable for control DC circuit of 11 KV VCBs and after assembling required voltage is 108 V / 100 AH complete all as specified and directed.
5
-
-
... More
M&L lifting, transporting, handling of the transformer from work site to the workshop / factory and including necessary tools, plants and return back to work site / MES yard / MES store, lifting, handling safely to custody etc. after rectifing faults / rewinding / repair / maintenance etc. complete all as specified and directed.
2
-
-
... More
M&L re-windings of HT distribution transformers of any capacity / size/ type by strip opening of HT coils (i.e. Primary coils) from core assembly safely, unwinding the HT (i.e. Primary coils) and including removing the old defective insulation paper, rewinding with new copper wire of same gauge and existing size together with new DPC insulation to the copper conductor, varnishing of the windings, heating/ drying/ backing complete carefully and thoroughly inside the heating chamber at suitable temperature to obtain required value of insulation resistance, testing commissioning the transformer and recording the test results etc, complete all as specified and directed.
120
-
-
... More
M&L earthing complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick, buried directly and preferably vertically in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanised earth strip 32 x 6 mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3, connected to earthing point of outdoor panel boards and including necessary earth work and excavation in any type of soil, PCC 1:3:6 type C1 chamber & RCC 1:2:4 type B1 cover 40 mm thick, with 8 mm dia steel deformed (TMT bars) reinforcement at 150 mm c/c both ways, 20 mm dia GI medium grade pipe for watering, water funnel and including taking down complete all as specified and directed.
8
-
-
... More
Supply & replacement of aluminium strip of size 25 x 3 mm size for connecting to earth terminal to HT panel, transformer, four pole, two pole wide wall or recess or chases or buired in ground or fixed to poles complete all as specified and directed.
120
-
-
... More
M&L brickwork with fly ash bricks, straight or curved on plan exc. 6 m mean radius, built in modular brick in CM 1:6 and including demolition complete all as specified and directed.
1.5
-
-
... More
M&L rendering on fair faces of brick work or concrete surfaces in two coats with first coat of 10 mm thick in CM1:6 and second coat of 5 mm thick in CM 1:4 mixed with water proofing compound as per manufacturers instructions, finished fair and even with out using extra cement complete all as specified and directed.
Note: The quoted rate is deemed to be include the cost of WPC.
40
-
-
... More
M&L PCC 1:2:4 type B1 using 20 mm graded aggregate for sub base of hydrant stand post foundation and finished with smooth surface complete all as specified and directed.
1.5
-
-
... More
M&L plates (plain or chequered) Channels, square cut or notched (Ordinary and counter sunk) forming holes, without any attachment, complete duly painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
225
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%