Military Engineer Services Tender

To know what Andhra Pradesh government has posted about any AP etender, Bidassist helps us to get a one-stop platform where a registered bidder can have access to the details on each and every eprocurement tender. There is no need to provide the details on the AP E-procurement website i.e. https://www.apeprocurement.gov.in as BidAssist helps us find the specific etender we're looking for. BidAassist has collated each and every Eproc Andhra Pradesh Tender on its website.

Military Engineer Services - MES Tender

Works
Building Construction
Eprocure
Opening Date9 Sep 2024
Closing Date1 Nov 2024
Tender Amount₹ 19,66,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Price worked out by the contractor for "INTERNAL WATER SUPPLY", against the price inserted by MES as listed in Schedule 'A' Part - III

1

-

1269983.84

... More
Price worked out by the contractor for "INTERNAL ELECTRIC SUPPLY", against the price inserted by MES as listed in Schedule 'A' Part - IV

1

-

6002363.25

... More
Price worked out by the contractor for "EXTERNAL WATER SUPPLY", against the price of Rs. 1,21,669.88 inserted by MES as listed in Schedule 'A' Part - V

1

-

456179.66

... More
Price worked out by the contractor for "EXTERNAL ELECTRIC SUPPLY ", against the price inserted by MES as listed in Schedule 'A' Part - VI

1

-

1690583.7

... More
Price worked out by the contractor for "SEWAGE DISPOSAL", against the price inserted by MES as listed in Schedule 'A' Part - VII

1

-

450883.71

... More
Price worked out by the contractor for "AREA DRAINAGE", against the price inserted by MES as listed in Schedule 'A' Part - VIII

1

-

1176775.25

... More
Price worked out by the contractor for "ROAD/ PATH/ CULVERT/ HRD STANDING ", against the price inserted by MES as listed in Schedule 'A' Part - IX

1

-

2147878.94

... More
Price worked out by the contractor for "FIRE FIGHTING AND FIRE ALRAM SYSTEM ", against the price inserted by MES as listed in Schedule 'A' Part - X

1

-

1369693.8

... More
Price worked out by the contractor for "LIGHTNING PROTECTION", against the price inserted by MES as listed in Schedule 'A' Part - XI

1

-

140101.86

... More
Price worked out by the contractor for "HOT WATER SUPPLY", against the price inserted by MES as listed in Schedule 'A' Part - XII

1

-

762245.04

... More
Price worked out by the contractor for "TELEPHONE/ LAN/ TV CONDUIT", against the price inserted by MES as listed in Schedule 'A' Part - XIII

1

-

121701.6

... More
Price worked out by the contractor for "AVIATION OBSTRUCTION LIGHT", against the price inserted by MES as listed in Schedule 'A' Part - XIV

1

-

12738

... More
Price worked out by the contractor for "IVERTER WIRING", against the price inserted by MES as listed in Schedule 'A' Part - XV

1

-

164213.28

... More
Price worked out by the contractor for "SEWAGE TREATMENT PLANT", against the price inserted by MES as listed in Schedule 'A' Part - XVI

1

-

102459.1

... More
Price worked out by the contractor for "RAIN WATER HARVESTING", against the price inserted by MES as listed in Schedule 'A' Part - XVII

1

-

99206.61

... More
Price worked out by the contractor for "SEWAGE TREATED WATER SUPPLY", against the price inserted by MES as listed in Schedule 'A' Part - XVIII

1

-

110937.4

... More
Price worked out by the contractor for "CHAINLINK FENCING & GATE", against the price inserted by MES as listed in Schedule 'A' Part - XIX

1

-

166896.37

... More
Schedule "A" Part - XX [Miscellaneous Items]

-

-

-

... More
INTERNAL WATER SUPPLY

-

-

-

... More
S&F Two way Angle cock ,fancy type Bib taps, 15mm dia cast copper alloy chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed.

84

-

-

... More
INTERNAL ELECTRIFICATION

-

-

-

... More
S & F LED bulb 9 Watt lumen not less than 770 Lumen complete all as specified and directed.

255

-

-

... More
S & F Wall mounting decorative type fitting suitable for fixing LED 9/10W B22 lamp complete all as directed.

255

-

-

... More
S & F modular metal box and modular white cover plate with frame 8 way

84

-

-

... More
S & F modular metal box and modular white cover plate with frame 12 way

12

-

-

... More
S&F Modular power unit (AC box white) with 3 pin socket with 20A, 240V, MCB complete all as directed.

180

-

-

... More
EXTERNAL WATER SUPPLY

-

-

-

... More
M & L for Pumping sets, monoblock with mechanical seal, electric driven, supply and Install complete inclusive of starter and PCC foundation 7.5 HP head 24 M and Discharge 800 LPM.

1

-

-

... More
Supplying and fix Cast Iron Air release kinetic type valve with two air Outlets,80 mm dia bore and fixing Up in GI water supply mains 80 mm dia including and jointing materials complete with rubber gasket, bolts and nuts etc. Complete all as specified and directed.

1

-

-

... More
Supply and fix Foot Valve conforming to IS 4038, 100 mm (4”) dia.

1

-

-

... More
Supply and fix Strainer Y type conforming to IS, size 100 mm (4”) dia.

1

-

-

... More
Supply, installation, testing and commissioning 3 phase and neutral, 415 volts indoor type, factory made CPRI approved free standing, floor mounting, dust and vermin proof cubical type, LT Panel fabricated from 2 mm thick CRCA sheet with anti corrosive coating and finally epoxy polyester powder coating of flint Grey shade fully compartmentalized design with 4 Nos of copper bus bar of 200 Amps capacity each and supply and fixing the following :- Incoming (a) MCCB 63A, 4 pole 25 KA-1 No (b) Ammeter 0-40 Amps 96 mm square digital type. (c ) Voltmeter --500V -01 No digital type 96 mm square (d) 01 set of 3 nos LED indication lamp Outgoing :- (a) MCCB 25 Amps 16 KA TP , 415 Volts -04 Nos (3 pumps & one spare) (b) Fully automatic star delta starter complete with contactor, relay etc of capacity 5HP- 03 Nos

1

-

-

... More
Supply, laying, connecting, testing and commissioning 16 sq mm PVC insulated and sheathed, multistranded copper cable single core, 1100 volts grade conforming to IS-694 and drawn into PVC pipe under floor complete all as directed by Engineer in charge.

60

-

-

... More
Fixing cost For MS reducer, bail plug , Well Cap , MS Strip for centering MS iron clamps , electric Logging and Sample Strata Box

1

-

-

... More
Trial bore of 200 mm dia up to 100 mtr depth below ground level in any kind of soil including hard stone/boulders including electric logging , MS cap, MS flat iron clamps, reducing socket etc complete all as directed

100

-

-

... More
Material and labour developing of trial bore for Reaming upto 675 mm for 60 meter from ground level including MS casing pipe of 200 mm dia and thickness 8 mm and pea gravel

60

-

-

... More
Material and labour developing of trial bore for Reaming upto 525 mm for 60 meter to 120 meter from ground level including MS casing pipe of 200 mm dia and thickness 8 mm and pea gravel

40

-

-

... More
Additional cost for slotted pipe of 200 mm dia in lieu of casing pipe of 200mm dia (30 RM Each bore well)

30

-

-

... More
Development of tube well with compressed air and after 25% extra capacity pump by pumping muddy water

24

-

-

... More
Yield test for the bore well by continuously pumping for 16 hrs to determine safe pumping yield

1

-

-

... More
Supply and fixing PVC insulated and PVC sheathed cable with electrolytic grade annealed copper conductor cable having 3 core flat for submersible pump and motor up to and including 1100 volts of size 10 sq mm

160

-

-

... More
Submersible pump ,electric driven 415 V TP suitable for 200/250mm dia bore well (Casing pipe size 200/250 mm ) supplied and installed completed ,5 HP complete all as directed

25

-

-

... More
Strainer Y type conforming to IS supplied and installed complete of size 200 mm dia

1

-

-

... More
Supply and fix Altoch dosing system.Model ADS-PRO .

1

-

-

... More
EXTERNAL ELECTRIC SUPPLY

-

-

-

... More
Supply and installation out door type Ring main unit one incoming two outgoing SF6 filled load break switch each of 11 KV ,630 Amp

1

-

-

... More
Supply , installation, testing and commissioning of copper wound transformer step down outdoor type complete with standard fittings HT 11 KV, 3 Phase, LT 433 volts with tapping on HT side to vary secondary voltage within limit, all as per IS-2026 of capacity 250 KVA with level 3 complete all as specified and directed.

1

-

-

... More
Supply, installation, testing and commissioning 3 phase and neutral, 415 volts out door type, factory made free standing, floor mounting, dust and vermin proof cubical type, LT Panel fabricated from 3.15 mm thick CRCA sheet with anti corrosive coating and finally epoxy polyester powder coating of flint Grey shade, fully compartmentalized design with 4 Nos of copper bus bar of 500 Amps capacity each and supply and fixing the following :-( Main LT Panel) Incoming (a) Air Circuit Breaker with Microprocessor IPR E , 4 pole 630 amps drawout type of 50 KA-1 No (b) Ammeter 0-200 Amps 96 mm square digital type. (c ) Voltmeter --500V -01 No digital type 96 mm square & LED Indication lamps etc., Outgoing (a) MCCB 250 Amps , 4 pole, 415 Volts 16 KA - 03 ( Block 1 ,APFC Panel , Spare) (b) MCCB 100 Amps , 4 pole, 415 Volts 25 KA - 03 (Block 2, DG Set Panel, spare)

1

-

-

... More
Supply, installation, testing and commissioning 3 phase and neutral, 415 volts out door type, factory made free standing, floor mounting, dust and vermin proof cubical type, LT Panel fabricated from 3.15 mm thick CRCA sheet with anti corrosive coating and finally epoxy polyester powder coating of flint Grey shade, fully compartmentalized design with 4 Nos of copper bus bar of 300 Amps capacity each and supply and fixing the following :- ( DG Set Panel) Incoming (a) MCCB 100 A, 4 pole 25 KA-1 No (b) Online Change Over switch 125 A (c) Ammeter 0-200 Amps 96 mm square digital type. (d ) Voltmeter --500V -01 No digital type 96 mm square & LED Indication lamps etc., Outgoing (a) MCCB 32 Amps 4 Pole, 415 Volts , 16 KA - 01 Nos ( Pump Panel) (b) MCCB 40 Amps 4 Pole, 415 Volts , 16 KA - 03 Nos ( Lift Panel -2, & spare -01) (c ) MCCB 63A 4 pole 415 V , 16 KA - 01 Sewage Panel -01 (d ) MCB 32 Amps SPN 415 Volts , 10 KA -01 Nos (Street light ) (e) time switches 250 V single Phase of 20 Amp rating- 01 Nos

1

-

-

... More
Supply, installation, testing and commissioning 3 phase and neutral, 415 volts out door type, factory made free standing, floor mounting, dust and vermin proof cubical type, LT Panel fabricated from 3.15 mm thick CRCA sheet with anti corrosive coating and finally epoxy polyester powder coating of flint Grey shade, fully compartmentalized design with 4 Nos of copper bus bar of 300 Amps capacity each and supply and fixing the following :- ( Building Panel 01 Nos for Block 1) Incoming (a) MCCB 250 A, 4 pole 25 KA-1 No (c) Ammeter 0-200 Amps 96 mm square digital type. (d ) Voltmeter --500V -01 No digital type 96 mm square & LED Indication lamps etc., Outgoing (a) MCCB 40 Amps 4 Pole, 415 Volts , 16 KA - 8 Nos ( each floor & spare)

1

-

-

... More
Supply, installation, testing and commissioning 3 phase and neutral, 415 volts out door type, factory made free standing, floor mounting, dust and vermin proof cubical type, LT Panel fabricated from 3.15 mm thick CRCA sheet with anti corrosive coating and finally epoxy polyester powder coating of flint Grey shade, fully compartmentalized design with 4 Nos of copper bus bar of 300 Amps capacity each and supply and fixing the following :- ( Building Panel 01 Nos for Block 2) Incoming (a) MCCB 100 A, 4 pole 25 KA-1 No (c) Ammeter 0-200 Amps 96 mm square digital type. (d ) Voltmeter --500V -01 No digital type 96 mm square & LED Indication lamps etc., Outgoing (a) MCCB 40 Amps 4 Pole, 415 Volts , 16 KA - 6 Nos ( each floor & spare)

1

-

-

... More
Supply, installation, testing and commissioning 3 phase and neutral, 415 volts out door type, factory made free standing, floor mounting, dust and vermin proof cubical type, LT Panel fabricated from 3.15 mm thick CRCA sheet with anti corrosive coating and finally epoxy polyester powder coating of flint Grey shade, fully compartmentalized design with 4 Nos of copper bus bar of 200 Amps capacity each and supply and fixing the following :- ( Lift panel) Incoming (a) MCCB 40 A, 4 pole 25 KA-1 No (c) Ammeter 0-200 Amps 96 mm square digital type. (d ) Voltmeter --500V -01 No digital type 96 mm square & LED Indication lamps etc., Outgoing (b) MCCB 32 Amps 4 Pole, 415 Volts , 16 KA - 02 Nos ( 01 Lift & spare) (c ) MCB TPN 40 Amp 240/415V 50Hz 10KA -01 Nos(Common area)

2

-

-

... More
S&F thermoplastic cable junction box complete with terminal suitable for 16/25 sq mm cable and fixed on steel tubular pole with all fixing arrangement complete all as directed (Cat Part No. K 9255 of Hensel or equivalent as approved by GE)

10

-

-

... More
Boring of holes under road, pavement hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150mm dia suitable for 0.4mpa working pressure

18

-

-

... More
Supply and fix route indicator for 1.1KV line voltage and fixed on ground proper interval as per latest IS

30

-

-

... More
ROAD/PATH/CULVERT/HARD STANDING

-

-

-

... More
M&L for including preparation of new/old road surfaces and applying road marking paint 2 to 2.5mm thickness (white), width exceeding 10 cm with retro-reflective hot thermoplastic road marking paint conforming to BS 3262:Part-I 1989 with 20% glass beads (Inter mixed) spread & laid by automatic mechanical machine Engine drive as in centre line, side line road marking of 150/100 mm width using HOT MARK by indigenous modern propelled road marking machine as directed including ingredients such as blinders, glass beads titanium dioxide calcium carbonate inter filler, thermoplastic requirements for glass beads shall be the table no.800.4 of MOST specifications including spraying of glass etc all as manufacture's instructions complete all as specified and directed.

38

-

-

... More
SEWAGE DISPOSAL

-

-

-

... More
Designing (hydraulically, structurally and aesthetically), and constructing RCC sumps in M-30 mix of required capacity including excavation in all types of strata, foundation concrete, container walls, bottom slab, top RCC roof slab with CI manhole covers and with plaster and water proofing as per zonal specification including epoxy paint inside, refilling of earth and disposal of surplus earth within 50 m lead, including all piping connections, valves, internal electrification, MS ladder, ventilation shaft, BB chambers with 5m of outer wall of tank complete including test for water tightness and hydraulic functioning. Avg Flow 51-100 Cum/day.

2

-

-

... More
SMART METERS

-

-

-

... More
Design, supply, install, commission integrate and maintain the advanced Metering Infrastructure (AMI) comprising of following for single phase meter :- (a) Supply, installation, commissioning of smart Meters of different makes (not more than 33% of a particular make to ensure interchangeability at a BIS 16444 with communication technology including GPRS/RF or Canopy/Hybrid ( RF+ GPS)/ Any other advanced technology as per CEA/TRAI regulations. (b) Supply/Planning/Setup/tuning of RF communication infrastructure including Network Management (NMS) & Head End System (HES) for the project area. AMI Software and associated equipment's should be capable of handling at-least 152 number of Meters of different makes as per BIS 16444 with 25 % expansion without any additional infrastructure and cost implication to MES, (c) Supply and setup of Meter Data Management (MDM) system. (d) Integration of different devises of different makes/equipment/software's covered in scope of this project with each other as per functional requirements, including water charges, furniture and license fee. (e) Integration/interface of the AMI system with application systems like Metering /Billing/Collection. Interface has to be provided in the proposed solution to upload and process meter data from these systems. (f) Hosting the system to Govt Community cloud ( GCC) for hosting and management of supplied software application with standby server at GSP. (g) Planning,deployment & tuning of communication system including Cellular network ( If required ) to meet the performance requirements. (h) Business Intelligence, Analytics and Reporting. (j) Return of Dismantled materials to MES stores. (k) Training and knowledge transfer. (l) All expenditure including periodic charges of telecom operator from installation till completion. NOTE : (i) The defects liability period will be 2 years from date of completion (ii) The metering infrastructure mentioned above is for all the 220 meters.

28

-

-

... More
S&F PVC meter box, single/three phase, anti corrosive, dust proof, rust proof, self extinguishing property, resistant to heat, vermin & water proof, Ultra violet stabilised, meter box made from Glass reinforced Polyester, sheet moulding compound (SMC) confirming to IS : 13410(1992) and attached technical specification , drawing and IS14772 : 2000.complete all as directed.

28

-

-

... More
RAIN WATER HARVESTING

-

-

-

... More
construction of Soakage pit of size 3mx3m in any type of soil, foundation in PCC 1:3:6, wall of Honey combed masonry with top ring of M 25 concrete including intercepting chamber and screen chamber made of brick masonary in CM, RCC cover slab and M 25 SFRC cover, interconnection pipes of RCC/DWC complete filled with brick bats complete all as per drawing and as specified.

1

-

-

... More
TV Connection

-

-

-

... More
Supply and fix PVC insulated telephone cable 4P for indoor applications confirming to TEC specification G/WIR06/02, UNARMOURD 0.5 mm ATC

1100

-

-

... More
S &F PVC insulated coaxial cable for indoor application for TV

560

-

-

... More
S &F Rj modular telephone socket

56

-

-

... More
S & F TV Socket , Coaxial socket 1 module complete all as specified

84

-

-

... More
FIRE FIGHTING

-

-

-

... More
Supplying, laying, connected, testing and commissioning Cast Iron Air Realised valve with two air Outlets, 50 mm dia bore and fixing Up in ERW water supply mains 100 mm dia including and jointing materials complete with rubber gasket, bolts and nuts etc. Complete all as specified and directed.

2

-

-

... More
Supply and laying, connecting testing and commissioning PVC insulated, unarmoured 3.0 core 25 sqmm, 1100 volt grade copper conductor cable heavy duty connected from LT panel to Motor terminals including copper themboling as per required all as specified and directed.

60

-

-

... More
Supply, installation, testing and commissioning 3 phase and neutral, 415 volts indoor type, factory made CPRI approved free standing, floor mounting, dust and vermin proof cubical type, LT Panel fabricated from 2 mm thick CRCA sheet with anti corrosive coating and finally epoxy polyester powder coating of flint Grey shade (RAL-7032), fully compartmentalized design with 4 Nos of copper bus bar of 200 Amps capacity each and supply and fixing the following :- Incoming (a) MCCB 20 A, 4 pole 25 KA-1 No (b) Ammeter 0-40 Amps 96 mm square digital type. (b ) Voltmeter --500V -01 No digital type 96 mm square (d) 01 set of 3 nos LED indication lamp Outgoing :- (b) Fully automatic star delta starter complete with contactor, relay etc of capacity 5 HP- 01 No

2

-

-

... More
Supply and fix Multipurpose fire extinguisher dry chemical powder (ABC) type 6 Kg capacity (IS 15683) with necessary fixing accessories etc. all specified and directed.

14

-

-

... More
Supply and fix fire extinguisher CO² type 4.5 Kg capacity (IS: 15683) with necessary accessories etc. all specified and directed.

14

-

-

... More
Supply, laying & testing PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor of size 1.5 sq mm ,2 core, 1100 Volts grade including wall mounting /ceiling mounting with saddles clamps ,screw,junction boxes and required cable gland with necessary earthing etc complete all as specified and directed.

560

-

-

... More
AVIATION LIGHT

-

-

-

... More
Supply and fix solid state electronic type aviation obstruction light fitting LED with cast aluminium poly carbonate red colour, with connecting &testing complete on top of the hangars all as directed by GE

4

-

-

... More
SEWAGE TREATMENT PLANT

-

-

-

... More
Design (Hydraulically, structurally & aesthetically), Supply, construction, installation, testing & commissioning of Sewage Treatment Plant based on Moving Bed Bio-reactor (MBBR) Technology having Capacity 30 KLD  at DEF MD ACCN FOR OFFICERS Bhubaneswar The scope of the work includes all necessary work as per relevant BIS . Treated sewage can be used for arboriculture. The major items are listed below and nothing extra will be payable for any technically required connected items :- MAKES :   Ion exchange India Ltd , Thermax Limited, M/S Optimus Enviropro Pvt Ltd  and ALL OEM approved by E-in-C Branch. Note: The quoted rate is deemed to included with the following items to be provided for each plant.

1

-

-

... More
SCREEN CHAMBER & FINE BAR SCREENS: The bar screen chamber shall be of RCC construction with design MIX grade M-30. Fine bar screens of MSEP construction to be installed in bar screen chamber at an angle of 60' to prevent floating objects passing through it and subsequently removing manually and dumped for further disposal. Oil & Grease removal: One number of chamber in RCC construction with design mix concrete of grade M-30, to be constructed. Equalisation tank : One number of RCC construction with design mix concrete of grade M-30, of min capacity 40m3, to cater for the peak discharge including provision of diffused air to ensure that septic conditions do not occur in tank at all. AIR GRID: One lot of air grid of material SS for providing aeration in the Equalization tank, MBBR Tanks etc. SEWAGE PUMPS: Two nos nonclog Raw sewage pumps (01 Active + 01 Standby) of minimum capacity 2.5m3/hour at a head of 10 M. capcaity complete with motor and all necessary accessories and fittings to be installed for transferring sewage from equlization tank to the process tanks. Level sensor should be provided in the tank and interlinked with pumps for automatic ON-OFF operation as per water level in the tank. One pressure gauge or each pump has to be provided to measure pressure at the outlet. AIR BLOWER: Two nos, Twin lobe Air Blower with acoustic enclosure complete with air blower capacity 75 m3/H and all necessary accessories & fittings for providing air in Equilization tank and MBBR tanks. One No. Air Rotameter is to be provided in each line to the MBBR tank and Equilization tank etc. for measurement of quantity of air. ANOXIC CHAMBER: One Anoxic Chamber capacity 5m3 of material MS FRP along with Mixer 0.5 HP. ANOXIC PUMPS: Two nos, Anoxic pumps (01 Active + 01 Standby) complete with capacity 8 m3/Hour at 10 Mtr Head and all necessary accessories and fittings to be installed for transferring sewage from Anoxic tank to the MBBR tanks with timer based operation for set time

-

-

-

... More
MBBR TANKS: Two nos. MBBR Tanks of suitable sizes in MS FRP construction with all internals including Media, SS air grid & SS rise pipe, Media retaining sieves etc. LAMELLAR SETTLER TANK: One Set of Lamellar settler tank of material MS FRP . complete with all internals comprising of media supporting structure & collection trough SLUDGE COLLECTION TANK: Sludge collection tank of adequate capacity shall be provided. CHLORINE CONTACT TANK: One No. Chlorine Contact cum filter feed tank of material MS FRP of min capacity 25 m3 . CHLORINE DOSING SYSTEM: One set of Chlorine dosing system complete comprising of dosing tank of min 100 litre capacity. Two nos, Dosing pumps (01 Active + 01 S/B ) complete with necessary connection for dosing of solution in chlorine contact tank. FEED PUMPS: Two Nos. filter feed centrifugal monoblock pumps of min 1.0 HP and flow rate 2.5 cum/hr at 30 Mtr Head, complete with motor and all necessary accessories and fittings for feeding tertiary treatment unit, Level sensor should be provided in the chlorine contact cum filter feed tank and interlinked with pumps for automatic ON-OFF operation as per level in the sump. One pressure gauge for each pump has to be provided to measure pressure at the outlet. MULTI GRADE FILTER: One No. Multi Grade Filter of material MSEP complete with media, frontal piping, valve and pressure gauges to measure pressure across the filter of minimum 600 mm dia and 1875 mm height. ACTIVATED CARBON FILTER: One No. Activated Carbon Filter of material MSEP complete with media, frontal piping, Valve and pressure gauge to measure pressure across the filter min 600mm dia and height 1800 mm.

-

-

-

... More
TREATED WATER TANK: One No. Treated Water Tank of material MSFRP construction of min capacity 10 m3 , to collect treated water after tertiary treatment for disposal of water for gardening/arboriculture CLEAR WATER PUMPS: Two nos, Treated water monoblock pumps (01 Active + 01 Standby) for discharge of min 03 lps, minimum head 10 mtr. complete with motor, foot valve, non return valve, etc and all other necessary valves, accessories and fittings to be installed for pumping treated water for gardening/ arboriculture. PIPES AND VALVES: One lot of Suitable size Piping & Valves of suitable material to interconnect various units as per site layout. 

-

-

-

... More
"TESTING: Testing and commissioning of STP will include testing of all electro-mechanical equipments, treated effluent parameters for treatment of the sewage, etc starting from collection chamber to outlet of tertiary treatment plant. (i) The plant shall be run continuously for minimum 72 hours. Test will be carried out in the presence of GE and Engineer-in-Charge, Contractor/rep of contractor and Rep of OEM. Contractor shall deploy adequate technical staff to operate the plant continuously for 72 hours and he shall be liable to carry out all the maintenance / rectification required during this period . (ii) The contractor shall afford all facilities and make all necessary arrangements for these tests at his own cost. All arrangements including various instruments required to facilitate testing shall be arranged by contractor. (iii) If the test results are not acceptable, all repairs and replacement and extra work of removal and relaying or refixing shall be carried out by the contractor at his own expense and the STP plant will be retested, until test results indicate compliance with the prescribed requirement. (iv) The installation shall be taken over by MES after the plant has been successfully commissioned and tested . (v) Quarterly test report of the treated effluent will be submiited by the contractor during the period of DLP."

-

-

-

... More
TEST EQUIPMENT: The contractor will submit the following test equipments deemed to be included in the contract. a) pH Meter Digital- 01 Nos b) TDS Meter Digital Tester-01 Nos c) Chlorine Testing Kits-03 Nos

-

-

-

... More
NOTES:-  (i) Defect liability period of Two year.  (Repair / replacement/spares of various plant components, including labour for such work covered under performance Guarantee) (ii) The items given above are indicative only. Any items required over and above items, for complete and efficient functioning of the plant is deemed to be included in the rates quoted by the tendered. (iii) The treated water should be get tested by the contractor from IIT/Regional Govt Lab or lab approved by EinC and test report should confirm that parameters of treated water are within the limit, as mentioned in the PS, should be submitted before seeking completion of the work. (iv) Rates of Minor civil work for foundation of machinery etc deemed to be included in the work. (v)  All works shall be carried out by skilled technicians of relevant trade under supervision of rep of OEM. (vi) The routing of cables/pipes/drains etc , shall have proper protection. The workmanship, finish, general appearance & layout of the plant shall be technically correct and aesthetic; all as directed by Engineer in Charge. (vii) Tenderer’s offered rate shall be deemed to include training and operation for 1 month after completion of the plant.

-

-

-

... More
Supply & fixing testing and commissioning LT panel board in door type factory made duly finished, double door, cubical type floor mounted of suitable size , Made out from 2 mm thick CRCA sheet powder coated mounted on angle iron frame (50mmx50mmx6 mm thick) from structure , three phase 440 volts with suitable high conductivity epoxy painted aluminium bus bars - 04 Nos. mounted on porcelain insulators, drill for out going connection, prewired using suitable size of copper wire, using proper lugs / thimbles including din rail for fixing of MCCBs/MCBs, cable glands of suitable sizes for incoming and outgoing cables complete all as specified and directed including the necessary PCC work and with and including following :- (a) MCCB 63 Amp,36 KA,4 Pole-01 No (Incomer ) (b) MCCB 40 Amp,25KA,4 Pole-02 No (Outgoing) (c) Digital voltmeter 0 to 500 volts with selector switch - 01set (d) Digital Amp meter with CTs and selector switch- 01 set

1

-

-

... More
LIFT

-

-

-

... More
Design supply, install, testing and commissioning of 13 passengers Lift in the existing lift well, speed 1.5 metre/sec, lift with single speed motor of 415 volts, 3 phase, 50 Hz AC supply conforming to IS-14665, suitable to serve G + 5 upper floors i.e. with 6 stops and 6 landings with AC Variable Voltage & Variable Frequency drive (VVF drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendant, centre opening sliding steel door with moon rock finish of 16 gauge with door drive (electric motor driven mechanism), sliding stainless steel doors, automatic rescuer device (ARD) system with batteries, 3D infra red sensor in full height of door & built in announcing system without hand set (04 Nos, one each in car, Machine room & near Ground floor landing door), complete all as specified and directed. NOTE : (i) The contractor is required to under go MoU with the OEM having registered with ‘’Govt of Tamilanadu Electrical Inspectorate’’ having valis license and shall submit the same within 15 days from commencement of work. (ii) Cost of new lift license from CEIG approval is deemed to be in the rate quoted by the bidder.

1

-

-

... More
(a) TECHNICAL SPECIFICATIONS (i) Type & Capacity: Passenger elevator for 13 persons (884Kg). (ii) Type of drive: Variable voltage and variable frequency drive with microprocessor based controller + 5 mm landing accuracy with speed encoder. (iii) Speed: 1.5 meter per second. (iv) Travel: Suitable for passenger travel of Approx 18 meters, (opening on same side). (v) Existing well size: 2900 mm x 2300 mm deep (over plaster) (approx) without any projected beam/column. (vi) Power supply: 03 Phase, 415 V, 50Hz (should withstand variation of + 5%). (vii) Inner size: 2000mm x 1100mm deep (Approx). (viii) Car enclosure: Stainless steel panel body of 16 gauge with moon rock finish, SS false ceiling (hairline finish) and stainless steel handrail of standard dia and size with hair line finish and splinter proof mirror of 4mm thickness in front half of the lift car.

-

-

-

... More
(ix) Flooring: Polished granite flooring. (x) Electric light: LED Light fitting (Min 04 Nos). (xi) Fan: Fresh Air fan 380mm sweep – 01 No. (xii) Car entrance: Automatic, centre opening, sliding doors. (xiii) Clear opening: Not less than 900mm x 2000mm high. (xiv) Operation door: Automatic operation with stainless steel frame front opening landing door of toughened glass not less than 12 mm thick. (xv) Control: Simplex full collective with and without attendant. (xvi) Indicators: Hall position indicators for car & landing direction and position indicator with stainless steel fixtures at all floors.(xvii) Main drive and control shall be latest , high efficient and low power consumption.

-

-

-

... More
(b) STANDARD FEATURES (i) Anti nuisance car call protection. (ii) Automatic car return device (home landing). (iii) Independent service (for duplex only). (iv) Overloading device with tripping system including warning indicator both audio and visual types. (v) Nudging buzzer if door is held open for more than 30 sec.. (vi) Emergency fireman’s service. (vii) Audible car call button. (viii) Emergency car light unit. (ix) High performance contact free infrared curtain door protection. (x) Door time protection. (xi) Emergency alarm button. (xii) Extra door time of lobby & parking. (xiii) Door open close button. (xiv) Manual rescue operation. (xv) Belt inspection device. (xvi) Suitable phase reverse relay shall be provided to the controller to protect lift against phase reversal, phase failure and low voltage. (xvii) Set of three limit switches at the bottom and top most position of lift hoist ways as specified in IS. (xviii) Indoor communication to be connected with nearest security post.

-

-

-

... More
(c) ADDITIONAL FEATURES (i) Automatic rescue device.: During power failure and manual operation suitable provision shall be provided to run the lift with full load to the nearest floor (ii) Floor announcement system :Each floor shall be provided with announcement system.

-

-

-

... More
(D) HUMAN INTERFACE DEVICE (HID) (i) Hall button with micro stroke push buttons combined with 16-segment digital LED display position indicator. (ii) Full height car operating panel with micro stroke call push buttons (located on side panel) . (iii) Door open/Door closed on car operating panel. (iv) 2-way intercommunication system. (v) Monochrome LED digital position indicator display. (vi) Battery operated alarm bell & emergency light. (vii) Fireman’s switch at main lobby. (viii) Manual rescue operation. (ix) Call register indicator in all landings. (x) Attendant operation system in car panel.

-

-

-

... More
NOTES (i) Contractor should keep the lift functional by repairing/replacing [as decided by GE(I)] the components during the defects liability period.

-

-

-

... More
Design supply, install, testing and commissioning of 13 passengers Lift in the existing lift well, speed 1.5 metre/sec, lift with single speed motor of 415 volts, 3 phase, 50 Hz AC supply conforming to IS-14665, suitable to serve G + 4 upper floors i.e. with 5 stops and 5 landings with AC Variable Voltage & Variable Frequency drive (VVF drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendant, centre opening sliding steel door with moon rock finish of 16 gauge with door drive (electric motor driven mechanism), sliding stainless steel doors, automatic rescuer device (ARD) system with batteries, 3D infra red sensor in full height of door & built in announcing system without hand set (04 Nos, one each in car, Machine room & near Ground floor landing door), complete all as specified and directed. NOTE : (i) The contractor is required to under go MoU with the OEM having registered with ‘’Govt of Tamilanadu Electrical Inspectorate’’ having valis license and shall submit the same within 15 days from commencement of work. (ii) Cost of new lift license from CEIG approval is deemed to be in the rate quoted by the bidder.

1

-

-

... More
(a) TECHNICAL SPECIFICATIONS (i) Type & Capacity: Goods elevator (1000Kg). (ii) Type of drive: Variable voltage and variable frequency drive with microprocessor based controller + 5 mm landing accuracy with speed encoder. (iii) Speed: 1.0 meter per second. (iv) Travel: Suitable for passenger travel of Approx 18 meters, (opening on same side). (v) Existing well size: 2900 mm x 2300 mm deep (over plaster) (approx) without any projected beam/column. (vi) Power supply: 03 Phase, 415 V, 50Hz (should withstand variation of + 5%). (vii) Inner size: 2000mm x 1100mm deep (Approx). (viii) Car enclosure: Stainless steel panel body of 16 gauge with moon rock finish, SS false ceiling (hairline finish) and stainless steel handrail of standard dia and size with hair line finish and splinter proof mirror of 4mm thickness in front half of the lift car.

-

-

-

... More
(ix) Flooring: Polished granite flooring. (x) Electric light: LED Light fitting (Min 04 Nos). (xi) Fan: Fresh Air fan 380mm sweep – 01 No. (xii) Car entrance: Automatic, centre opening, sliding doors. (xiii) Clear opening: Not less than 900mm x 2000mm high. (xiv) Operation door: Automatic operation with stainless steel frame front opening landing door of toughened glass not less than 12 mm thick. (xv) Control: Simplex full collective with and without attendant. (xvi) Indicators: Hall position indicators for car & landing direction and position indicator with stainless steel fixtures at all floors.(xvii) Main drive and control shall be latest , high efficient and low power consumption.

-

-

-

... More
(b) STANDARD FEATURES (i) Anti nuisance car call protection. (ii) Automatic car return device (home landing). (iii) Independent service (for duplex only). (iv) Overloading device with tripping system including warning indicator both audio and visual types. (v) Nudging buzzer if door is held open for more than 30 sec.. (vi) Emergency fireman’s service. (vii) Audible car call button. (viii) Emergency car light unit. (ix) High performance contact free infrared curtain door protection. (x) Door time protection. (xi) Emergency alarm button. (xii) Extra door time of lobby & parking. (xiii) Door open close button. (xiv) Manual rescue operation. (xv) Belt inspection device. (xvi) Suitable phase reverse relay shall be provided to the controller to protect lift against phase reversal, phase failure and low voltage. (xvii) Set of three limit switches at the bottom and top most position of lift hoist ways as specified in IS. (xviii) Indoor communication to be connected with nearest security post.

-

-

-

... More
(c) ADDITIONAL FEATURES (i) Automatic rescue device.: During power failure and manual operation suitable provision shall be provided to run the lift with full load to the nearest floor (ii) Floor announcement system :Each floor shall be provided with announcement system.

-

-

-

... More
(D) HUMAN INTERFACE DEVICE (HID) (i) Hall button with micro stroke push buttons combined with 16-segment digital LED display position indicator. (ii) Full height car operating panel with micro stroke call push buttons (located on side panel) . (iii) Door open/Door closed on car operating panel. (iv) 2-way intercommunication system. (v) Monochrome LED digital position indicator display. (vi) Battery operated alarm bell & emergency light. (vii) Fireman’s switch at main lobby. (viii) Manual rescue operation. (ix) Call register indicator in all landings. (x) Attendant operation system in car panel.

-

-

-

... More
NOTES (i) Contractor should keep the lift functional by repairing/replacing [as decided by GE(I)] the components during the defects liability period.

-

-

-

... More
SCHEDULE 'A' PART -XXI (MANNING AND OPERATION OF STP)

-

-

-

... More
Manning and Operation by deploying manpower of 01 operator per shift for operating 35KLD packaged type STP plant for 02 Shifts/day, technical support and operation guidence to operators, monitoring all the mechanical & electrical equipments, analysing the treated water sample once in a month complete all as directed.

-

-

-

... More
(a) Operation and maintenance during 1st year after completion of work

12

-

-

... More
(b) Operation and maintenance during 2nd year after completion of work

12

-

-

... More
SCHEDULE 'A' PART -XXII (COMPREHENSIVE MAINTENANCE OF LIFT WORK& OPERATION AND MAINTENANCE OF STP)

-

-

-

... More
Comprehensive maintenance, servicing and repairs including renewal/replacement of defective parts of electrically operated 13 passengers Lift after 2 years of defect liability period suitable to ground plus five floors ( G + 5 upper floors ) i.e with 6 stops and 6 landings & ( G + 4 upper floors ) i.e with 5 stops and 5 landings) with speed 1.5 m/s and Automatically operated door system.

-

-

-

... More
(a) Comprehensive maintenance on 1st year after expiry of defects liability period

12

-

-

... More
(b) Comprehensive maintenance on 2nd year after expiry of defects liability period

12

-

-

... More
(c) Comprehensive maintenance on 3rd year after expiry of defects liability period

12

-

-

... More
Notes for Serial Item Nos -111 to 113 above :- (i) The rate quoted are deemed to include all/any charges related to renewal of lift license and lift insurance from State Govt/Other Agency. (ii) The rate is inclusive of all items as required at site including any spares to keep the lift operated all the time. (iii) The Maintenance of the lifts should be done through the OEM. (iv) The contractor should attend the complaint/breakdown immediately. (v) Maintenance of the lift should be done as per manufacturer instructions

-

-

-

... More
Operation and maintenance including deploying manpower of 01 operator per shift for operating 35KLD packaged type STP plant for 02 Shifts/day, technical support and operation guidence to operators, providing chemicals & consumables, monitoring all the mechanical & electrical equipments, analysing the treated water sample once in a month complete all as directed.

-

-

-

... More
(a) Operation and maintenance during 1st year after expiry of defects liability period

12

-

-

... More
(b) Operation and maintenance during 2nd year after expiry of defects liability period

12

-

-

... More
(c) Operation and maintenance during 3rd year after expiry of defects liability period

12

-

-

... More
Notes for Serial Item Nos -116 to 118 above :- (i) The rate quoted are deemed to include all items as required at site including any spares to keep the STP operational all the time. (ii) The contractor should attend the complaints/breakdown immediately. (iii) Operation & Maintenance of the STP should be done as per manufacturers instructions.

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.