To know what Andhra Pradesh government has posted about any AP etender, Bidassist helps us to get a one-stop platform where a registered bidder can have access to the details on each and every eprocurement tender. There is no need to provide the details on the AP E-procurement website i.e. https://www.apeprocurement.gov.in as BidAssist helps us find the specific etender we're looking for. BidAassist has collated each and every Eproc Andhra Pradesh Tender on its website.

Military Engineer Services - MES Tender

Works
Civil And Construction
Civil Works Others
Building Construction
Eprocure
Opening Date20 Sep 2024
Closing Date12 Nov 2024
Tender Amount₹ 58,13,00,000 
Notes
Download

Costs

Summary

Construction Of Otm Accn And Allied Facilities

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Price worked out by the contractor for "EARTH WORK AND SITE CLREARENCE", against the price inserted by MES as listed in Schedule 'A' Part - III

1

-

7400140.31

... More
Price worked out by the contractor for "INTERNAL WATER SUPPLY", against the price inserted by MES as listed in Schedule 'A' Part - IV

1

-

279127.75

... More
Price worked out by the contractor for "INTERNAL ELECTRIC SUPPLY", against the price inserted by MES as listed in Schedule 'A' Part - V

1

-

7936320.19

... More
Price worked out by the contractor for "EXTERNAL WATER SUPPLY ", against the price inserted by MES as listed in Schedule 'A' Part - VI

1

-

327352.61

... More
Price worked out by the contractor for "EXTERNAL ELECTRIC SUPPLY", against the price inserted by MES as listed in Schedule 'A' Part - VII

1

-

2166451.3

... More
Price worked out by the contractor for "SEWAGE DISPOSAL", against the price inserted by MES as listed in Schedule 'A' Part - VIII

1

-

1107411.47

... More
Price worked out by the contractor for "AREA DRAINAGE", against the price inserted by MES as listed in Schedule 'A' Part - IX

1

-

18711645.57

... More
Price worked out by the contractor for "HARD STANDING ", against the price inserted by MES as listed in Schedule 'A' Part - X

1

-

1637998.54

... More
Price worked out by the contractor for "ROAD/CULVERT ", against the price inserted by MES as listed in Schedule 'A' Part - XI

1

-

12299963.78

... More
Price worked out by the contractor for "RAIN WATER HARVESTING", against the price inserted by MES as listed in Schedule 'A' Part - XII

1

-

160914.2

... More
Price worked out by the contractor for "AIR CONDITIONING", against the price inserted by MES as listed in Schedule 'A' Part - XIII

1

-

304266.36

... More
Price worked out by the contractor for "FIRE FIGHTING, FIRE DETECTION AND FIRE ALARM SYSTEM", against the price inserted by MES as listed in Schedule 'A' Part - XIV

1

-

994760

... More
Price worked out by the contractor for "TELE & LAN ( SOCKET CONDUIT )", against the price inserted by MES as listed in Schedule 'A' Part - XV

1

-

185536

... More
Price worked out by the contractor for "COOLING APLIANCES", against the price inserted by MES as listed in Schedule 'A' Part - XVI

1

-

534260.74

... More
Price worked out by the contractor for "SOLAR WATER HEATER", against the price inserted by MES as listed in Schedule 'A' Part - XVII

1

-

283853.8

... More
Price worked out by the contractor for "LIGHTNING PROTECTION", against the price inserted by MES as listed in Schedule 'A' Part - XVIII

1

-

144077

... More
Price worked out by the contractor for "SECURITY WALL/GATE/CATLE TRAP ", against the price inserted by MES as listed in Schedule 'A' Part - XIX

1

-

19528359.18

... More
Price worked out by the contractor for "PILE FOUNDATION ", against the price inserted by MES as listed in Schedule 'A' Part - XX

1

-

81305119.33

... More
Price worked out by the contractor for "DEMOLITION ", against the price inserted by MES as listed in Schedule 'A' Part - XXI

1

-

17823

... More
Schedule "A" Part - XXII [Miscellaneous Items]

-

-

-

... More
AREA DEVELOPMENT AND SOIL STABILISATION

-

-

-

... More
Supply and Laying Stratum foundation mattreses made of uniaxial geocell of depth 0.65m (HDPE Geogrid + Bodkin connectors) all as specified as directed .

20918

-

-

... More
Supplying and laying 200 GSM needle-punched non-woven geotextile as per manufacturer instructions and as directed.

20918

-

-

... More
Supplying and Laying The Multi axial PP grid for MSL (Mechanically Soil Stabilisation) application, manufactured from an extruded, polymer sheet, which is then punched and oriented. The resulting structure consists of continuous and non- continuous ribs forming three aperture geometries (hexagon, trapezoid, and triangle) and an unimpeded suspended hexagon. The rib aspect ratio 1, with radial secant stiffness of 100 kN/m (-10kn/m) at 2% strain and radial secant stiffness ratio of 0.7 to 0.8 with distance between alternate parallel ribs as 80mm. The stabilization geogrid shall have 100% (within tolerance of -10%) junction efficiency and minimum 2% finely divided carbon black, well dispersed in the polymer matrix to inhibit attack by UV rays all as specified and as directed.

20918

-

-

... More
NOTE FOR SL ITEM NO. 24,25 & 26: (i) Rates quoted against the items shall deemed to be included for providing design, supply and laying stratum cellular foundation mattresses for ground improvement using comprising HDPE Uniaxial and Bodkin connectors, Finite Element Analysis and construction methodology along with periodic technical assistance during fabrication and filling of stratum mattresses. (ii) The horizontal surface area shall only be measured and paid. (iii) : The granular fill into the stratum foundation mattresses shall be measured and paid seperately . (iv) Makes : TENSAR/ MACCAFERRI / GIRIDHAR TECH FAB PVT LTD

-

-

-

... More
M&L for Crusher dust filling in floors or pavings, laid in layers not exceeding 25cm thick, spread, leveled and rammed including watering and rolling complete all as specified and as directed complete all as specified and as directed.

32945.7

-

-

... More
Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. including consolidating the soil with mechanical means to achieve 97% modified proctor density complete for all lifts all as specified and as directed.

13597

-

-

... More
INTERNAL ELECTRIC SUPPLY

-

-

-

... More
S & F LED bulb 10 Watt lumen not less than 770 Lumen complete all as specified and directed

50

-

-

... More
Supply and fixing of luminaire -Decorative wall mounted light including LED lamp of 9/10W complete with all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size

15

-

-

... More
Supply and fixing of 3W/4W portable LED table lamp with multifunctional Base complete in all respect as required.

30

-

-

... More
S & F modular metal box and modular white cover plate with frame 2 Module

40

-

-

... More
S & F modular metal box and modular white cover plate with frame 3 Module

745

-

-

... More
S & F modular metal box and modular white cover plate with frame 4 Module

40

-

-

... More
S & F modular metal box and modular white cover plate with frame 6 Module

40

-

-

... More
S & F modular metal box and modular white cover plate with frame 8 Module

12

-

-

... More
S & F modular metal box and modular white cover plate with frame 10 Module

25

-

-

... More
S & F modular metal box and modular white cover plate with frame 12 Module

7

-

-

... More
S & F modular metal box and modular white cover plate with frame 16 Module

5

-

-

... More
S & F sheet metal TPN DB 12 way double door recess to wall with 200 Amps rated bus bar Four pole with neutral.

10

-

-

... More
S & F sheet metal TPN DB 8 way double door recess to wall with 200 Amps rated bus bar Four pole with neutral.

7

-

-

... More
EXTERNAL WATER SUPPLY

-

-

-

... More
S&F Cl foot valve for size 80mm bore complete all as specified and directed

2

-

-

... More
S&F Cl foot valve for size 63mm bore complete all as specified and directed

2

-

-

... More
Construction of brick masonry using fly ash bricks valve chamber of internal size 600 mm x 600 mm x 600 mm with PCC 1:3:6 type C2 ( using 40 mm graded aggregate) for foundation- 75 mm thick, brick walls in CM 1:4-230mm thick, PCC 1:2:4 type B1 for copings 50 mm thick, rendering in CM 1:4 - 15 mm thick both the sides , provision of MS sheet cover 3mm thick fixed to MS angle frame made out of 40x40x6mm thick with locking arrangement complete and two coats of synthetic enamel paint over one coat of red oxide primer, including necessary excavation and earth work and removal of surplus soil to a distance not exc 50m in any type of soil complete all as specified and as directed.

10

-

-

... More
Supply, install, testing and commissioning of non clog submersible pump set .(For Drain Pump) 5HP , electrically driven 3 ph, 415 volts, 'F' class insulation, IP 44 protection TEFC Motor, CI impeller, Sealing - Gland Packing,, with discharge capacity not less than 15 LPS at minimum head 20 mtr, suction and delivery size 80x65 mm, including k) with PVC flexible pipe 80 mm dia - 4RM and electrical connection from starter to pump set with and including flat copper wire 4 Sqmm x 3 Core protected with PVC flexible pipe of required length complete all as specified and directed . Note: - All accessories required such as clamps, hanging rope ,nuts bolt, welding work, wire lugs etc deemed to be included in the quoted rate.

2

-

-

... More
Supply, install, testing and commissioning of centrifugal mono-block pump set 5HP , electrically driven 3 ph, 415 volts, RPM-3000, 'F' class insulation, IP 44 protection TEFC Motor, CI impeller, Sealing - Gland Packing,, with discharge capacity not less than 6.8 LPS at minimum head 28 mtr, suction and delivery size 65x50 mm, including base frame made of MS Channel 75mm x50mm, with required nuts and bolts, 01 No pressure gauge 0 to 7 kg /cm2 , 01 No brass foot valve 80 mm bore (ISI mark) with PVC flexible pipe 80 mm dia - 4RM and electrical connection from starter to pump set with and including copper wire 4 Sqmm x 3 Core protected with PVC flexible pipe of required length complete all as specified and directed . Note: - All accessories required such as clamps, nuts bolt, welding work, wire lugs etc deemed to be included in the quoted rate.

2

-

-

... More
Supply and fix DOL Starter for monoblock pump set 5 HP (pump house panel)

4

-

-

... More
EXTERNAL ELECTRIC SUPPLY

-

-

-

... More
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. 300 mm dia. R.C.C. Pipe complete :

40

-

-

... More
Supply, installation, testing & commissioning of 4 pole structure with cross arms, suitable clamps, insulators, disc insulators, 11KV lightning arrestors, complete stay with insulator & wire, foundations, gang operated air break switch with drop out fuses. This shall have termination arrangement for incoming & outgoing through cable and necessary 6 inches dia GI pipe shall be provided for cable support.

1

-

-

... More
Supply, install,testing and commissioning of Inoor type floor mounted metal clad 33KV RMU panel with 3 Nos VCB totally enclosed and fully interlocked, horizontal draw out, horizontal/ vertical isolation type breaker as per IS 13118, as amended upto date and additional specification, having capacities as mentioned below, single break, trip free mechanism, having facility of both auto & manually charged and auto/ manually closing breaker suitable for use on 33KV, 3 Phase, 50 Hz AC supply with short circuit fault level of 350MVA, complete with self contained fully interlocked, rack in and rack out mechanism air insulated but encapsulated copper bus bars of 400 Amps, 26.5 KA capacity, breaker featured with mechanical ON/OFF indicator with hand trip device, spring release coil, shunt trip coil and auxiliary switch of 3NO+3NC and equipped with following switchgears and accessories i/c connections suitable for 3x120sq mm XLPE 33 KV cable (cable entry from bottom/ side) and termination with heat shrinkable jointing material etc. as required.

1

-

-

... More
INCOMING PANEL - 1 No. (i) 1 no. 400Amp VCB (ii) 1 No 33KV/110 Volts PT class 0.5 accuracy and 100 VA burden with 1 No voltmeter (0-36 KV) digital type, selector switch for voltmeter and protection MCB for HT metering upto 26.3 KA (iii) 1 No (0-25A) dual scale Ammeter, digital type selector switches for Ammeter 1no. Set of Dual core dual ratio 3 CTs 300/150/5/5A of 15VA burden & accuracy class 0.5 for metering and class 5P 10 for protection (iv) 1 No set of dual core dual ratio 3 CTs 50/25/5/5A of 15VA burden & accuracy class of 0.5 for metering and class 5P 10 for protection. (v) 1 No Microprocessor based numerical relay with O/L, E/F & S/C protection (vi) One strip heater to prevent absorption of moisture. OUTGOING PANEL - 2 Nos. (i) 2 nos. 400Amp VCB (ii) 2 Nos (0-25A) dual scale Ammeter, digital type selector switches for Ammeter (iii) 2 Nos set of dual core dual ratio 3 CTs 50/25/5/5A of 15VA burden & accuracy class of 1.0 for metering and class 5P 10 for protection (iv) 2 Nos. Microprocessor based numerical relay with O/L, E/F & S/C protection (v) 8 window solid state audio/ visual enunciators with Test/ Accept/Rest push buttons and electronic hooter (vi) Including control cabling from HT panel to Transformer (vii) Power pack with 220V AC input and 24V DC continuous output suitable for closing/tripping/ indication of 3nos. VCB panels with 2nos. 12V maintenance free batteries of 100AH (Suitable) each charging unit capacitor bank for emergency delivering for trip system complete with suitable capacity of Ammeter and Voltmeter including connections with 2.5sq mm FRLS insulated copper conductor cable etc. as required (viii) Cable box with single compression brass glands suitable size to receive 33 KV XPLE cable of 3 core upto 240 sq mm. 2nos. (0-100A) dual scale Ammeter, digital type selector switches for Ammeter 2nos. Set of Dual core dual ratio 3 CTs 100/50/5/5A of 15VA burden & accuracy class 1.0 for metering and class 5P 10 for protection 2 Nos. Microprocessor based numerical relay with O/L, E/F & S/C protection 8 window solid state audio/visual annuciators with Test/Accept/Reset push buttons and electronic hooter. Including control cabling from HT panel to Transformer. Power pack with 220V AC input and 24V DC continuous output suitable for closing/tripping/ indication of 3nos. VCB panels with 2nos. 12V maintenance free batteries of 100AH (Suitable) each charging unit capacitor bank for emergency delivering for trip system complete with suitable capacity of Ammeter and Voltmeter including connections with 2.5sq mm FRLS insulated copper conductor cable etc. as required. Cable box with single compression brass glands suitable size to receive 11 KV XPLE cable of 3 core 185/240 sq.mm.

-

-

-

... More
Supply ,install ,testing and commissioning indoor cubical type APFC with capacitor bank made out of 2 mm CRCA sheet and angle iron frame work IP-52 protection , incoming MCCB, double di-electric heavy duty MD-XL capacitors with control switches , power contractors , MCBs etc complete for automatic/manual operation of rating 12 steps 400 KVAR (5x50+5x25+1x15+10).

1

-

-

... More
Supply, installation, testing and commissioning of factory made, CPRI type tested, indoor, cubical compartmental type LT Panel of suitable size, conforming to IEC 61641, having front side openable with hinged single door & locking arrangement and IP 54 protection made out of 2.00 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labeling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel sheet, vitreous enameled (white) with letters figures and conventional skull and bones in signal red colour, suitable for 3- Phase 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length & size, including fixing lugs, bolts, screws etc. complete all as specified and directed by the engineer-in-charge. PANEL-X (P2) The LT Panel shall comprise of the following: [A] BUSBAR CHAMBER [i] 01 Set (3L + N) of Al bus bar of rated capacity 1500 A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connection INCOMER :- (i) ACB 4 Pole, 415 V, 50 KA ,Manual Draw out type with microprocessor release of capacity 1000 Amps-01 No OUTGOING :- (i)MCCB 630A TP MCCB with isolable neutral.-01 No (ii) MCCB 400A 4P 415 V-1 Nos. (iii) MCCB 200A 4P 415V-1 Nos. (iv) MCCB 125A 4P 415 V.-1 Nos. (v) MCCB 100A 4P 415 V-3 Nos. (vi) Digital type Ammeter , range 0 to 1000 Amp with selector switch and CT -01No (vii) Digital type Volt meter, range 0 to 500 Volt with selector switch and PT-01No (viii) Indicator lamp RYB-01 set

1

-

-

... More
Supply, installation, testing and commissioning of factory made, CPRI type tested, indoor, cubical compartmental type LT Panel of suitable size, conforming to IEC 61641, having front side openable with hinged single door & locking arrangement and IP 54 protection made out of 2.00 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labeling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel sheet, vitreous enameled (white) with letters figures and conventional skull and bones in signal red colour, suitable for 3- Phase 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length & size, including fixing lugs, bolts, screws etc. complete all as specified and directed by the engineer-in-charge. PANEL-A(P2) The LT Panel shall comprise of the following: [A] BUSBAR CHAMBER [i] 01 Set (3L + N) of Al bus bar of rated capacity 1000 A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connection INCOMER :- (i) 630 Amp MCCB 4 Pole, 415 V, with Microprocessor release with breaking capacity 50 KA - 01 No OUTGOING :- (i)MCCB 125A 4P -2 Nos. (ii)MCCB 500A 4P -2 Nos (iii)SPN feeder having 32A DP MCB-1 Nos. (iv) Digital type Ammeter , range 0 to 630 Amp with selector switch and CT -01No (v) Digital type Volt meter, range 0 to 500 Volt with selector switch and PT-01No (vi) Indicator lamp RYB-01 set

1

-

-

... More
Supply, installation, testing and commissioning of factory made, CPRI type tested, indoor, cubical compartmental type LT Panel of suitable size, conforming to IEC 61641, having front side openable with hinged single door & locking arrangement and IP 54 protection made out of 2.00 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labeling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel sheet, vitreous enameled (white) with letters figures and conventional skull and bones in signal red colour, suitable for 3- Phase 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length & size, including fixing lugs, bolts, screws etc. complete all as specified and directed by the engineer-in-charge. PUMP HOUSE PANEL The LT Panel shall comprise of the following: [A] BUSBAR CHAMBER [i] 01 Set (3L + N) of Al bus bar of rated capacity 200 A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connection INCOMER :- (i) 125 Amp MCCB 4 Pole, 415 V, with Microprocessor release with breaking capacity 50 KA - 01 No OUTGOING :- (i)MCCB 100A 4P -2 Nos. (ii)MCCB 63A 4P -2 Nos (iii)MCB 32A DP-1 Nos. (iv) Digital type Ammeter , range 0 to 200 Amp with selector switch and CT -01No (v) Digital type Volt meter, range 0 to 500 Volt with selector switch and PT-01No (vi) Indicator lamp RYB-01 set

1

-

-

... More
Supply, installation, testing and commissioning of factory made, CPRI type tested, outdoor, cubical compartmental type LT Panel of suitable size, conforming to IEC 61641, having both sides openable with hinged double doors & locking arrangement and IP 54 protection made out of 3.00 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labeling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel sheet, vitreous enameled (white) with letters figures and conventional skull and bones in signal red colour, suitable for 3- Phase 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length & size, including fixing lugs, bolts, screws etc. complete all as specified and directed by the engineer-in-charge. PANEL-M The LT Panel shall comprise of the following: [A] BUSBAR CHAMBER [i] 01 Set (3L + N) of Al bus bar of rated capacity 600 A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connection INCOMER :- (i) 400 Amp MCCB 4 Pole, 415 V, with Microprocessor release with breaking capacity 50 KA - 01 No OUTGOING :- (i)MCCB 320A 4P 36Ka -2 Nos. (ii)MCCB 250A 4P -2 Nos (iii)MCCB 125A 4P -1 No (iv)MCCB 63A 4P -3 Nos (v)MCB SPN 40A-1 No. (vi) MCB SPN 32A -1No. (vii) Digital type Ammeter , range 0 to 630 Amp with selector switch and CT -01No (v) Digital type Volt meter, range 0 to 500 Volt with selector switch and PT-01No (vi) Indicator lamp RYB-01 set

1

-

-

... More
Supply, installation, testing and commissioning of factory made, CPRI type tested, indoor, cubical compartmental type LT Panel of suitable size, conforming to IEC 61641, having front side openable with hinged single door & locking arrangement and IP 54 protection made out of 2.00 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labeling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel sheet, vitreous enameled (white) with letters figures and conventional skull and bones in signal red colour, suitable for 3- Phase 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length & size, including fixing lugs, bolts, screws etc. complete all as specified and directed by the engineer-in-charge. SR PANEL-1 The LT Panel shall comprise of the following: [A] BUSBAR CHAMBER [i] 01 Set (3L + N) of Al bus bar of rated capacity 600 A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connection INCOMER :- (i) 200 Amp MCCB 4 Pole, 415 V, with Microprocessor release with breaking capacity 50 KA - 02 No OUTGOING :- (i)MCCB 63A 4P -2 Nos. (iv)MCB TPN 32A 4P -2 Nos (v)MCB SPN 63A-1 No. (vi) MCB SPN 32A -13No. (vii) Digital type Ammeter , range 0 to 630 Amp with selector switch and CT -01No (v) Digital type Volt meter, range 0 to 500 Volt with selector switch and PT-01No (vi) Indicator lamp RYB-01 set

1

-

-

... More
Supply, installation, testing and commissioning of factory made, CPRI type tested, indoor, cubical compartmental type LT Panel of suitable size, conforming to IEC 61641, having front sides openable with hinged single door & locking arrangement and IP 54 protection made out of 2.00 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labeling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel sheet, vitreous enameled (white) with letters figures and conventional skull and bones in signal red colour, suitable for 3- Phase 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length & size, including fixing lugs, bolts, screws etc. complete all as specified and directed by the engineer-in-charge. LOG PANEL-1 The LT Panel shall comprise of the following: [A] BUSBAR CHAMBER [i] 01 Set (3L + N) of Al bus bar of rated capacity 600 A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connection INCOMER :- (i) 250 Amp MCCB 4 Pole, 415 V, with Microprocessor release with breaking capacity 50 KA - 02 No (01x for solar connection) OUTGOING :- (i)MCB TPN 63A 4P -2 Nos (ii)MCB TPN 40A 4P-5 No. (iii) Digital type Ammeter , range 0 to 630 Amp with selector switch and CT -01No (iv) Digital type Volt meter, range 0 to 500 Volt with selector switch and PT-01No (v) Indicator lamp RYB-01 set

1

-

-

... More
Supply, installation, testing and commissioning of factory made, CPRI type tested, indoor, cubical compartmental type LT Panel of suitable size, conforming to IEC 61641, having front side openable with hinged single door & locking arrangement and IP 54 protection made out of 2.00 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labeling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel sheet, vitreous enameled (white) with letters figures and conventional skull and bones in signal red colour, suitable for 3- Phase 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length & size, including fixing lugs, bolts, screws etc. complete all as specified and directed by the engineer-in-charge. JR PANEL-1 The LT Panel shall comprise of the following: [A] BUSBAR CHAMBER [i] 01 Set (3L + N) of Al bus bar of rated capacity 200 A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connection INCOMER :- (i) 125 Amp MCCB 4 Pole, 415 V, with Microprocessor release with breaking capacity 50 KA - 02 No OUTGOING :- (i)MCB TP 40A -3 Nos (ii)MCB TPN 40A 3P-3 No. (iii) Digital type Ammeter , range 0 to 200 Amp with selector switch and CT -01No (iv) Digital type Volt meter, range 0 to 500 Volt with selector switch and PT-01No (v) Indicator lamp RYB-01 set

1

-

-

... More
Supply, installation, testing and commissioning of factory made, CPRI type tested, indoor, cubical compartmental type LT Panel of suitable size, conforming to IEC 61641, having front side openable with hinged single door & locking arrangement and IP 54 protection made out of 2.00 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labeling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel sheet, vitreous enameled (white) with letters figures and conventional skull and bones in signal red colour, suitable for 3- Phase 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length & size, including fixing lugs, bolts, screws etc. complete all as specified and directed by the engineer-in-charge. MI PANEL-1 The LT Panel shall comprise of the following: [A] BUSBAR CHAMBER [i] 01 Set (3L + N) of Al bus bar of rated capacity 200 A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connection INCOMER :- (i) 125 Amp MCCB 4 Pole, 415 V, with Microprocessor release with breaking capacity 50 KA - 02 No(01 for solar connection) OUTGOING :- (i)MCB TPN 63A 4P-2 Nos (ii)MCB TPN 40A 4P-2 No. (iii) Digital type Ammeter , range 0 to 200 Amp with selector switch and CT -01No (iv) Digital type Volt meter, range 0 to 500 Volt with selector switch and PT-01No (v) Indicator lamp RYB-01 set

1

-

-

... More
Supply, installation, testing and commissioning of factory made, CPRI type tested, indoor, cubical compartmental type LT Panel of suitable size, conforming to IEC 61641, having front side openable with hinged single door & locking arrangement and IP 54 protection made out of 2.00 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labeling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel sheet, vitreous enameled (white) with letters figures and conventional skull and bones in signal red colour, suitable for 3- Phase 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length & size, including fixing lugs, bolts, screws etc. complete all as specified and directed by the engineer-in-charge. ADMIN PANEL-1 The LT Panel shall comprise of the following: [A] BUSBAR CHAMBER [i] 01 Set (3L + N) of Al bus bar of rated capacity 500 A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connection INCOMER :- (i) 320 Amp MCCB 4 Pole, 415 V, with Microprocessor release with breaking capacity 50 KA - 02 No(01x for solar connection) OUTGOING :- (i)MCB TPN 40A 4P-4 Nos (ii) Digital type Ammeter , range 0 to 500 Amp with selector switch and CT -01No (iv) Digital type Volt meter, range 0 to 500 Volt with selector switch and PT-01No (v) Indicator lamp RYB-01 set

1

-

-

... More
Supply, installation, testing and commissioning of factory made, CPRI type tested, outdoor, cubical compartmental type LT Panel of suitable size, conforming to IEC 61641, having both sides openable with hinged double doors & locking arrangement and IP 54 protection made out of 3.00 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labeling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel sheet, vitreous enameled (white) with letters figures and conventional skull and bones in signal red colour, suitable for 3- Phase 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length & size, including fixing lugs, bolts, screws etc. complete all as specified and directed by the engineer-in-charge. PANEL-O The LT Panel shall comprise of the following: [A] BUSBAR CHAMBER [i] 01 Set (3L + N) of Al bus bar of rated capacity 400 A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connection INCOMER :- (i) 250 Amp MCCB 4 Pole, 415 V, with Microprocessor release with breaking capacity 50 KA - 01 No OUTGOING :- (i)MCB TPN 40A 4P-7 Nos (v)MCB SPN 40A-3 No. (vi) MCB SPN 32A -2No (ii) Digital type Ammeter , range 0 to 400 Amp with selector switch and CT -01No (iv) Digital type Volt meter, range 0 to 500 Volt with selector switch and PT-01No (v) Indicator lamp RYB-01 set

1

-

-

... More
Supply, installation, testing and commissioning of factory made, CPRI type tested, outdoor, cubical compartmental type LT Panel of suitable size, conforming to IEC 61641, having both sides openable with hinged double doors & locking arrangement and IP 54 protection made out of 3.00 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labeling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel sheet, vitreous enameled (white) with letters figures and conventional skull and bones in signal red colour, suitable for 3- Phase 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length & size, including fixing lugs, bolts, screws etc. complete all as specified and directed by the engineer-in-charge. Ext Light FEEDER PILLAR (OUTDOOR TYPE) The LT Panel shall comprise of the following: [A] BUSBAR CHAMBER [i] 01 Set (3L + N) of Al bus bar of rated capacity 200 A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connection INCOMER :- (i) 63A MCB 4 Pole, 415 V, with Microprocessor release with breaking capacity 10 KA - 01 No OUTGOING :- (i)MCB TP 25A 10Ka-02 Nos (ii) 24 Hours digital timerwith suitable capacity contactor - 02 nos (iii) Digital type Ammeter , range 0 to 200 Amp with selector switch and CT -01No (iv) Digital type Volt meter, range 0 to 500 Volt with selector switch and PT-01No (v) Indicator lamp RYB-01 set NOTE : Any other item required to make panel functional for auto switch ON/OFF street light shall deemed to be included in quoted rate.

1

-

-

... More
Note for Item 55 to Item 66 (i) Breaking capacity of MCCB and MCB should be used as follows: (a) up to 125 A-16KA (b) 160A to 630 A -36KA (ii) Over load release of MCCB/MCB should be used as follows: (a) up to 125 A -Adjustable thermal release(0.7 to 1.0 In) (b) 160A to 250 A-Adjustable thermal release(0.64 to 1.0 In) © 400A to 630 A- Electronic release with over load zone of adjustment 0.4 to 1.0In (ii) Short circuit release of MCCB/MCB should be used as follows: (a) up to 125 A -Fixed magnetic type suitable for 10.0In (b) 160A to 250 A-Adjustable magnetic release(3.5 to 10.0 In) © 400A to 630 A- Electronic release with short circuit zone of adjustment 1.5 to 10.0In(Adjustment current with time)

-

-

-

... More
Supply & Installation, commissioning and testing, indoor type 1000 KVA capacity of Type-II KNAN (Natural Ester Oil) Transformer, Indoor step down 33/0.433 KV, Copper Double wound, core type winding. AC supply 3 Phase, 4 wire 50 HZ, oil immersed, naturally Ester oil, delta connected on primary (HT side) and star connected on secondary (LV side) having tapping 0%, 2.5%,5%,7.5% on HV, to be charged by means of hand operated off load tap changing gear including first filling of oil and all standard fittings such as breather unit, drain out valve, conservator tank and mounting, complete all as specified in IS 1180:2014 (Part III) (Level-2) marked and shall comprise of the following. (a) HT side (primary) consisting of 03 Nos indoor porcelain bushing with brass rods, complete with nuts, bolts and washers complete and with cable box. (b) LT side (secondary) consisting of 04 Nos indoor porcelain bushing with brass rods, complete with nuts, bolts and washers complete and with cable box. (c) Oil conservator tank with filter type drain valve and oil level gauge. (d) De-hydrating breathe with first fill of dehydrating agent (Silica gel). (e) Explosive vent for for release of pressure will be provided on the cover. (f) Silica gel breathe along with conservator tank will be provided. (g) Two earthing terminal on tank cover to facilitate fixing of 5x6mm galvanized iron earth strip for earthing of neutral & body. (h) Rating plate and terminal marking plate 02 Nos. (j) Oil level gauge. (k) Oil drain filter valve. (l) 4 Nos Lifting lugs will be provided. (m) Oil filling hole with cap/ plug with connecting plate complete. (n) Air release valve plug. (o) Four plain solid cast steel heavy duty detachable rollers. (p) Extra bushing for neutral in the LT cable box for providing independent set of earthing for neutral complete. (q) First filling of new and unused transformer oil IS 335 marked filtered and tested for Di-electric strength not less than 42 KV at 2.0 mm gap between testing electrodes.

2

-

-

... More
M & L for cable jointing kit for 33KV (Earthed) grade cable for indoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armored aluminum conductor cable of size 120 sq mm complete

5

-

-

... More
Cable jointing kit for 33KV (Earthed) grade cable for indoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armored aluminum conductor cable of size 120 sq mm

2

-

-

... More
Supplying of following sizes of PVC insulated PVC sheathed copper conductor power cable of 1.1 KV grade 3 core 2.5 sq.mm

140

-

-

... More
Supply and fix Hot dip Galvanized Octagonal street light Poles of 7.0 meter long, Top dia 70mm , bottom dia 130mm and sheet thickness 3mm including top bracket for light fitting complete with base frame plate, foundation bolt, nut and washers, top etc.Window- Plasma cut and duly chamfered opening window of 300 x 110 mm for terminal connection and mounting accessories with suitable capacity MCBs. Window cover is fitted with allen screws to the pole complete all as specified and directed by Engr-in-charge.

20

-

-

... More
For Swivel lights on watch tower Supply and fixing manually rotating search light 250 watt HPSV/MH/LED. Low voltage, high intensity weather & dust proof flood light in aluminum body complete with highly polished stainless steel mirror reflector, toughened front glass fitted in the cast aluminum front retaining ring, insulated handle and swiveling cradle with suitable base.

2

-

-

... More
SEWAGE DISPOSAL

-

-

-

... More
Supplying & laying HDPE pipes, Double wall corrugated(DWC) in trenches with necessary specials complete all as specified and directed for 150 mm internal dia of pipes.

530

-

-

... More
Supplying & laying HDPE pipes, Double wall corrugated(DWC) in trenches with necessary specials complete all as specified and directed for 200 mm internal dia of pipes.

230

-

-

... More
S&F SFRC manhole cover and frame(Heavy duty HD- 20 grade designation) internal size 0.9m dia circular/ 1.2x0.90m rectangular conforming to IS 12592, fixed in cement concrete 1:2:4(using 20mm graded staone aggregate)including necessary form work complete all as specified and directed.

48

-

-

... More
Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete For pipes 100 to 250 mm diameter

4

-

-

... More
ROAD

-

-

-

... More
S&F reflective mirror concave of dia 800mm and mounted over mild steel pipe 40mm bore and 2.50mtr long including errection in position in PCC 1:2:4 Type B-1 size 450x450x900mm including removal of old base/excavation in post holes as required.

4

-

-

... More
Supply and fixing of Rubber speed breaker of Size W350xL500xH50mm with Yellow Black colour etc. complete as per directions of Engineer-In-Charge

12

-

-

... More
RAIN WATER HARVESTING

-

-

-

... More
Providing orange color safety foot rest of minimum 6mm thick plastic encapsulated as per IS : 10910 on12mm dia steel bar conforming to IS :1786 having minimum cross section as 23mm x 25mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protrude legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification make to be visible even after fixing, including fixing in manholes with 30x20x15cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) complete as per design.

32

-

-

... More
Boring holes 2 m deep in soil for under-reamed piles and getting out and disposal of spoil to a distance of n exc.50 m, 300 mm nominal bore

320

-

-

... More
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC (Slotted / Plain pipe) medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge, 200 mm nominal size dia

320

-

-

... More
Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tube well as per IS:2800 (part I).200 mm dia

2

-

-

... More
Boulders exceeding 15cm and upto 30cm dia.

7.07

-

-

... More
Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge.

7.07

-

-

... More
Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge.

7.07

-

-

... More
Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality , H D - 20 Circular shape 560 mm internal diameter

4

-

-

... More
AIR CONDITIONING

-

-

-

... More
Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2.of capacity 1.5 TR complete all as specified and directed. Note : (a) Contractor has to install the ACs as per drawing. (b) the cost of extra electric cable, copper pipes incl insulation, PVC pipe for water drain at suitable location, stand for fixing outdoor unit and 15Amps, 3 pin Plug top with LED indicator shall deemed included in quoted rate.

44

-

-

... More
Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2.of capacity 2.0 TR complete all as specified and directed. Note : (a) Contractor has to install the ACs as per drawing. (b) the cost of extra electric cable, copper pipes incl insulation, PVC pipe for water drain at suitable location, stand for fixing outdoor unit and 15Amps Plug top with LED indicator shall deemed included in quoted rate.

15

-

-

... More
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4.0 KVA

44

-

-

... More
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5.0 KVA

15

-

-

... More
Supply and fixing modular AC Box (white) with 3 pin socket two in one, all in one type, single pole and neutral box with one single pole MCB 16/20A, 230 Volts including modular metal Box, modular cover plate with frame of 4 module complete all as specified and as directed. Make- Havells cat no. DHDMCSN0251016 or equivalent make specified in PS.

59

-

-

... More
S & F sheet metal TPN DB 6 way double door recess to wall with 200 Amps rated bus bar Four pole with neutral.

4

-

-

... More
FIRE FIGHTING, FIRE DETECTION AND FIRE ALARM SYSTEM

-

-

-

... More
Providing, fixing, testing and commissioning of control panel for Terrace Booster pumps . Incoming: MCCB 35A 1 set of Phase indicating lamps, 1 set of 35A Al bus bars, 1No Ammeter, 1No Voltmeter with phase selector switch Feeder for Booster Pumps - 1 No. 1 No. 32A TP MCCB without releases. DOL starter with over load relay, single phase preventer and indicating lamps with ON/OFF push buttons. 1 No. Auto manual selector switch. Suitable for booster pumps

1

-

-

... More
Supply and fixing of fire point comprising the following :- (a) Fire extinguisher dry chemical powder (ABC) Type 6 Kg capacity - 01 No. (b) Fire extinguisher CO2 type Type 4.5 Kg capacity - 01 No. (c) Ceiling hook (d) Fire man Axe (e) Mechanical Foam 9 Litre

3

-

-

... More
TELE & LAN ( SOCKET CONDUIT )

-

-

-

... More
S&F Telephone socket - double RJ11 - 1 module complete all as specified and directed

80

-

-

... More
S&F Lan/CCTV Information socket - category 6-UTP - 1 module complete all as specified and directed

49

-

-

... More
S & F TV socket 1 module complete all as specified and directed

28

-

-

... More
COOLING APLIANCES

-

-

-

... More
Supply, installation, commissioning of refrigerator, electric driven (single phase), capacity not less than 310 Litres.BEE 5 star rated complete all as specified and directed.

2

-

-

... More
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4.0 KVA

9

-

-

... More
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 1.0 KVA

3

-

-

... More
STND BY POWER SUPPLY

-

-

-

... More
Supply, installation, test and commissioning of silent, Diesel engine driven factory assembled, floor mounted generating set of capacity 250 KVA/200 KW at 0.8 power factor or nearest higher size, 3 phase, 4 wire, 50 Hz, 1500 RPM as per IS 10001/10002 to take 10% over load complete with safety control and metering equipments mounted on & including common base frame with acoustic enclosure (canopy), weather proof as per CPCB norms,powder coated all as per manufacturer's instructions manual and all as specified and comprising of the items/ accessories listed hereinafter:-

1

-

-

... More
(A) Prime Mover : Directly coupled diesel engine, water cooled suitably de-rated of matching BHP for driving 250 KVA capacity, alternator electric start, four stroke confirming to latest IS-10001/10002 for continuous running and capable for taking 10% over load for 01 hour complete with following accessories:- (i) Fly wheel to suit flexible coupling. (ii) Flexible coupling with guards. (iii) Air cleaner with filters. (iv) Lubricating oil filter (v) Heavy duty radiator assembly with fan. (vi) Anti-vibration pad as recommended by manufacturers. (vii) PT pump with electronic governor of suitable capacity. (viii) Self starter 12 volts DC. (ix) Necessary arrangement for charging battery. (x) Maintenance free battery 12 volts , duly charged -01 No, capacity as supplied by manufacturer and as recommended by manufacturer along with flexible copper battery lead and connector. Make :- EXIDE/ AMCO/STANDARD as approved by GE.

-

-

-

... More
(x) Maintenance free battery 12 volts , duly charged -01 No, capacity as supplied by manufacturer and as recommended by manufacturer along with flexible copper battery lead and connector. Make :- EXIDE/ AMCO/STANDARD as approved by GE. (xi) Battery rack made out of MS angle iron 40 mm x 40 mm x 5 mm & 150 mm beight - 01 No.(xii) Standard safety device. (xiii) Daily services fuel tank for full running capacity of DG set for min 12 hours enclosed within the canopy all as per CPCB with lever indicator inlet, fuel outlet drain plug, air vent and locking arrangements etc including fuel pipe connections with connected GI pipe medium grade from fuel tank to DG set and over flow from the DG set to fuel tank complete with gate valve. (ixv) Exhaust system with Retrofit emission control device as per CPCB norms shall be provided with thermal insulation by using fire retardant/ non igniting foam conforming to BS-4735 to prevent excess heat radiation on the engine and safe for operator. (xv) Mechanical panel having following accessories :- (aa) Digital Lubrication oil temperature gauge - 01 No. (ab) Digital Lubrication oil pressure gauge - 01 No. (ac) Digital Water temperature gauge - 01 No. (ad) Starting switch with key - 01 No. (ae) Battery voltmeter.

-

-

-

... More
(af) Indicator lamp etc.(ag) Digital Ammeter DC-01 No.(ah) Digital RPM meter-01 No.(aj) Safety measures :(i) Low lubricant oil pressure trip.(ii) High coolant temp trip.(iii) Engine over speed trip.(iv) Battery charging alternator.(v) Emergency stop pressed. (B) Alternator : 250 KVA at 0.8 power factor, self regulated 3 phase with neutral 415 volts 50 Hz 1500 RPM as per IS : 13364 complete with automatic voltage regulator and foot mounted including making cable connection. The salient feature of alternator are as under :- (i) Voltage regulation under static condition + 1.5%.(ii) Class 'F' insulation.(iii) Permanently lubricating bearing.(iv) Capable to take 10% over load for one hour for every 12 hours. (C) Repair tools and 2 years maintenance spare parts as per following:- Repair Tools :- (i) Ring spanner set of 10-01 set. (ii) Screw driver 6”, 8”, 12”, 14” & 24”-02 each (iii) Spanner set of 01-01 set.(iv) Adjustable spanner 12” – 04 Nos. (v) Cutting pliers – 01 No. (vi) Techno meter- 01 No.(vii) Tools kit box (only box) – 01 No 2 Years Spare :- (a) Fan belt set complete - 01 No (b) Lub oil filter - 01 Set (c) Fuel filter - 01 Set (d) Service manual and spare part catalog with guarantee card (e ) Sock treatment chart dully framed - 01 Set (f) First Aid Box - 01 set (g) Fire extinguisher form - 01 set (h) Fire extinguisher (electricity ) - 01 set Make Engine :- Refer Appx 'A' to PS. Alternator :- Refer para 29 to PS.

-

-

-

... More
(E) ACCOUSTIC ENCLOSURE :- OEM made Acoustic enclosure (canopy) suitable for 250 KVA DG with the following provisions/ specifications :- (i) The enclosure fabricated out of CRCA sheet of 14 SWG suitable to accommodate the DG Set properly. (ii) The sheet metal components are hot dip seven tank pretreated. (iii) It is pure polyester based powder coated (inside as wall as outside). All nuts/bolts/hardwares are zinc coated with salt spray test as per ASTMB- 117. (iv) Battery is accommodated in a tray in the enclosure. (v) The doors are fitted with gasket with high quality EPON gasketed to avoid leakage of sound. (vi) Sound proofing of enclosure is done with high quality rock wool/mineral wool conforming to IS 8131 of 50 mm thickness and density of 96 kg/cum. (vii) The wool is further covered with fiber glass cloth and perforated powder coated sheet, insulation level conforming to UL 94 HF1 class flammability. (viii) A special residential silencer is provided within the enclosure to control exhaust noise. (ix) Specially designed alternators are provided to control sound at air entry to the container and exhaust from the container. (x) Adequate ventilation is provided to meet requirement for combustion and heat removal. If required a blower is used to meet total air requirement and air changes. (xi) Temperature of enclosure does not exceed beyond 50 degree C of ambient temperature. (xii) The enclosure is provided with “high enclosure temperature” safety device. (xiii) There is provision of emergency shutdown from out side the enclosure. (xiv) There is arrangement for proper illumination inside the canopy. (xv) Noise level is 75 DB (A) at 1 mtr distance. (xvi) Approved by CPCB. Note :- (i) The quoted rate for DG Set is inclusive of PCC foundation. The foundation for DG Set should be made of PCC 1:2:4 type B1 using 20mm graded stone aggregates below the floor level minimum 300mm and 300 mm above floor platform and of suitable size as per manufacturers recommendations complete all as directed by Engineer-in-Charge.

-

-

-

... More
(ii) The DG Set shall be suitable derated to suit the climatic condition of so as to give desired output including 10% over load. (iii) The DG Set shall be suitable for auto main failure function. (iv) AMF panel should of same manufacturer as that of DG Set manufacturer (v) The DHPP (fuel) required for testing of DG sets is deemed to be included in above quoted rate . (vi) Phase I test will be carried out by Engineer-in-charge for no load and 100% load for 1 hour each and phase II test will be carried out in presence of SEI/EI/IEM/Rep of accepting officer for no load, 25%, 50%, 75%, 100% for 11 hours and 110% for 1 hour over load. (v) CPCB Norms :- DG Set should be as per CPCB-IV Norms emission limit (g/KWH)standard as follows :- a) Oxides of Nitrogen + Hydrocarbon (NOx +HC ≤ 4.7) b) Carbon Monoxide (CO ≤ 3.5) c) Particulate Matter (PM ≤0.3) d) Smoke Limit (Light Absorption Coefficient, m-1) ≤0.7

-

-

-

... More
Supply, installation, test and commissioning of Control AMF Panel : AMF control panel Factory made, CPRI type tested, indoor, cubical compartmental type LT Panel of suitable size conforming to IEC 61641, having front side openable hinged single door and locking arrangement and IP 54 protection made out of 2.00 mm thich MS CRCA sheet , supported and fixed on structural steel frame of angle iron of suitable size, including earthing stud, labeling, painting to all internal & external exposed steel surfaces with powder coating paint(7 tank process), duly fixed on ground with PCC 1:2:4 , type B1, with danger notice plate of 1.6mm thick MS sheet , vitreous enamelled (white) with letters figures and conventional skull and bones in signal red colour complete.Suitable for 250 KVA DG set with by pass assessment including all necessary operating and control device (to meet the requirement of above capacity plus 25% over load) such as contactors, MCCBs, CT's, volts meter, Ammeter, indicating lamp, frequency meter, energy meter with protection fuses for panel instrument battery charging system with indicator and cut off relays low and high oil pressure, high speed over load and earth fault protection, reverse current protection duly wired copper conductor cable and cable connection with lugs/thimbles complete as recommended by manufacturers and as directed.

1

-

-

... More
Earthing complete with GI earth plate electrode of size 600 mm x 600 mm x 6 mm thick buried directly to ground vertically to a depth not less than 2.25 Mtr below the ground level with top edge of earth plate not less than 1.65 Mtr below normal ground level connected to GI strip 25 x 4 mm size and earthing lead protected with 50 mm dia GI pipe light grade filling around with charcoal dust and salt including excavation, returning, filling of earth and disposal of surplus soil to a distance not exceeding 50 mtr and connected to GI strip by means of GI nuts, bolts and washers strip connected to earth plate including chamber PCC 1 : 3 : 6 type C1. using 20 mm graded stone aggregate in concrete pit pre-cast RCC 40 mm thick reinforced with 6 mm dia round at the rate of 75 mm C/C both way with 12 mm dia mild steel plain bar lifting handle 2 Nos funnel with wire mesh 20 mm dia GI pipe light grade watering pipe and frame work complete all as shown in electrical plate No. 5 of SSR Part - I 1991 including testing complete. (GI strip upto 7.5 m length in included in unit rate quoted by contractor and beyond this lengths the same shall be measured & paid separately. (AMF -2,DG Set-4)

6

-

-

... More
BOOM BARRIER

-

-

-

... More
Supply,fix and testing manual Boom Barrier of length 6 meter of Stainless steel material with battery back up supply Including Electrical and civil works.. Operating temperatures from -10°C to +55°C IP rating IP54 Actuator weight 41kg Control unit LIBRA C MO Power supply 230V Motor power supply 24V Absorbed power 300W Opening or closing time 4 sec. / 2.5 sec (for toll naka) / 5 sec.

2

-

-

... More
Supply,fix and testing of Tyre killer of length 6 meter 230 V power,1 KW power consumption Including Electrical and civil works.

1

-

-

... More
SECURITY WALL/GATE/CATLE TRAP

-

-

-

... More
S&F 600mm dia punched type concertina coil (50 turns per coil) 0.5mm thick low carbon heavy galvanized cold rolled steel sheet as per IS:513,Confirm to heavy galvanized high tensile spring steel wire as per IS:4454 and confirming to heavy duty steel clips as per IS:2062 deep drawn quality with galvanizing coating (minimum 230GSM) having medium barbs of specification barb length :24+1mm pitch between two barbs 35+1 and weight of coil should not be less than 1.42 kg/Rm including fixed in position in between "Y" shaped angle iron post with barbed wire fence complete all as specified and directed by Engineer-in-Charge. Note:-The barbed wire shall be measured and separately .After stretching the concertina coil length of the compound wall on which it has been stretched shall be considered for measurement.

3870

-

-

... More
Designing, fabricating,installing and fixing in position Curtain wall with Aluminium composite panel Cladding with open grooves for linear as well as curvilinear portions for all heights including (a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design. (b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4 mm thick aluminium composite panel material consisting of 3 mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5 mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc.

15.4

-

-

... More
(c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building. The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places.

-

-

-

... More
PILE FOUNDATION

-

-

-

... More
Boring 500mm dia piles to any depth in any type of soil strata/soft/weather rock by DMC or any other approved method all as specified and as directed including mobilization & demobilization of piling equipment, making approaches to site etc complete

16905

-

-

... More
M&L for Boring for bored cast-in-situ pile 500mm dia through hard rock strata by any suitable method duly supported by drilling fluids or casing pipes including removal of excavated materials outside MD land

1691

-

-

... More
M&L for Non destructive integrity test on 500mm dia piles all as per IS-14893-2001 or ASTM std and all as specified and directed including bringing on site all equipment required and removal from site after testing is done

1102

-

-

... More
M&L for Initial load testing (vertical load testing) on 500mm dia as per IS2911 (Part-IV) - 1985 and all equipment required and removal from site after testing is done

3

-

-

... More
M&L for Lateral load testing on 500mm dia as per IS2911 (Part-IV) - 1985 and all as specified and directed including bringing on site all equipment required and removal from site after testing is done.

3

-

-

... More
M&L for Pull out testing on 500mm dia as per IS2911 (Part-IV)-1985 (Part-I Sec 2) and all as specified and directed including bringing on site all equipment required and removal from site after testing is done.

3

-

-

... More
M&L for Routine load testing (static load testing) on 500mm dia as per IS2911(Part-IV) - 1985 (Part-I sec 2) and all as specified and directed including bringing on site all equipment required and removal from site after testing is done.

17

-

-

... More
SOLAR PLANTS

-

-

-

... More
Designing, supply, erection, installation, commissioning and testing of roof top solar photovoltaic power plant (ON-GRID) of total 200 KWp capacity on Administrative building, Logistic block and Technical section, MI Room, Jr Sailor inliving block, Sr Sailors in living block fixed tilt type, and power evacuation at 415V 3 phase system all as per guidelines/ norms issued by MNRE & Andhra Pradesh state Electric agencies & Indian metrological Deptt approved solar radiation data viz direct normal irradiance, global horizontal irradiance etc complete comprising with the following :-

1

-

-

... More
(A) Solar PV modules :- Solar PV modules capable for total power plant capacity of Solar PV Array shall be 200KWp electricity at 415V 3 Phase system :- (i) Cell of the Modules shall be poly crystalline high power silicon elis. The solar cells shall have surface anti-reflective coating to help to absorb more light in all weather condition. (ii) The PV modules used must qualify to the latest edition of IEC PV module qualification test or equivalent BIS standards crystalline silicon solar cell modules IEC 61215/ IS 14286. In addition, the modules must confirm to IEC 61730 part-1 requirement for construction & part-2 requirements for testing, for safety qualification or equivalent IS. (iii) The net rated and certified capacity of solar PV array capacity at Standard Testing Conditions (STC) should not be less than allocated capacity KWP i.e 200KWp DC and should comprise of solar crystalline modules of minimum 335Wp and above wattage. Module capacity less than minimum 335 watts shall not be accepted. (iv) Protective devices against surges at the PV module shall be provided. Low voltage drop bypass diodes shall be provided. (v) To connect the solar modules interconnection cable shall be provided. Photoelectric conversion module-efficiency shall be greater than 16.0%. Modules shall be made of height transitivity glass front surface giving high encapsulation gain and silicon rubber edge sealant for module protection and mechanical support. PV Module shall be interconnected by MC-4 connector. The interconnection cable of PV Module must confirm NEC standard "USE-2 or RHW-2". (vi) It shall perform satisfactory in relative humidity upto 85% and temperature between 0 to 0.60 degrees. It shall be able to withstand wind gusts as per the relevant wind code applicable for site condition.

-

-

-

... More
(vii) (a)The rated output of any supplied module shall not vary by more than 3% from average power rating of all ratings. Each module, therefore, has to be tested and rating display. (b) The peak-power point voltage and the peak-power point current of any supplied module and/ or any module string series connected modules) shall not vary by more than 2 (two) per cent from the respective arithmetic means for all modules and / or for all module string. (c) The module shall be provided with a junction box with either provision of external screw terminal connection or sealed type and with arrangement for provision of by-pass diode. The box shall have hinged, weather proof lid with captive screws and cable gland entry points or may be of sealed type and IP-65 rated. (viii) Use of RF Identification tag (RFID) is mandatory for all PV modules, regardless of their capacity. Modules deployed must use a RF identification tag. (RFID shall be mandatorily placed as per MNRE guidelines). The following information must be mentioned in the RFID used on each modules. The PV panels shall fulfill the DCR(Domestic content requirement) criteria. RFID : Each PV module must use a RF identification tag mandatorily placed inisde the module laminate, which must contain the following information : (i) Name of the manufracture of PV module. (ii) Name of the manufracture of solar cells. (iii) Month and year of the manufrature (separetely for solar cells and module) (iv) Country of origin (separetely for solar cells and module) (v) I-V curve for the module (vi) Peak Wattage, Im, Vm and FF for the module. (vii) Unique Serial No. and Model No. of the module (viii) Date and Year of obtaining IEC PV module qualification certificate. (ix) Name of the test lab issuing IEC certificate (x) Other relevant information on tacceability of module as per ISO 9000 series. (xi) Provision of earthing & earth strip/cables etc. for earth for solar PV module/Array etc. as per latest IS/MNRE norms to be provided and the cost of the same is to be included in this item and no extra amount will be paid to the contractor on this account.

-

-

-

... More
(B) - Array Structure :- (i) Hot dip galvanized MS mounting structures of minimum 80 microns may be used for mounting the modules/ panels/ arrays. Each structure should have angle of inclination as per the site conditions to take maximum insulation, However to accommodate more capacity the angle inclination may be reduced until the plant meets the specified performance ratio requirements. The array structuring must be done in consultation with PGCIL. The mounting structure steel shall be as per latest IS 2062: 1992 and galvanization of the mounting structure shall be in compliance of latest IS 4759. (ii) The mounting structure shall be co-designed to withstand the speed for the wind zone of the location where a PV system is proposed to be installed. Suitable fastening arrangement such as grouting and calming should be provided to secure the installation against the specific wind speed.(iii) Structural material shall be corrosion resistant and electrolytically compatible with the materials used in the module frame, its fasteners, and nuts and bolts. Aluminium structures also can be used which can withstand the wind speed of respective wind zone. Necessary protection towards rusting need to be provided either by coating or anodization. (iv) The fasteners used should be made up of stainless steel. The structures shall be designed to allow easy replacement of any module. The array structure shall be so designed that it will occupy minimum space without sacrificing the output from the SPV panels. (v) Regarding civil structures the bidder need to take care of the load baring capacity of the roof and need to arrange suitable structures based on the quality of roof. (vi) Cable ties shall be used to proerlyhold the cables/ wires on the backside of PV modules, GI pipe with appropriate size shall be used to guide cables from PV array to JB to Inverter. The minimum height between cable guide and ground shall be 6 inch and the cable guide shall be supported on ground at appropriate locations so as to avoid any bending of the guide. (viii)The bidder should design the structure height to retain and increase aesthetics of the building. The minimum clearance between the lower edge of the module and the ground shall be minimum 6 inch over the terrace ground level/ roof structure. Contractor shall take dare of the ease of movement of manpower for cleaning and maintenance purpose. Further, contractor shall also consider all shading factors including parapet wall, overhead tanks, antenna, hardings etc. to offer better plant performance. (viii)The total load of the structure (when installed with PV modules) on the terrace shall be less than 60 kg/ m2. Roof treatment must be done to avoid seepage after installation work is over. PCC foundation for holding modules mounting structures foundation materials shall be as per M15 (1:2:4) concrete specification.

-

-

-

... More
(C)-JUNCTION BOXES - (i)The junction boxes are to be provided in the PV array for termination of connecting cables. The junction boxes shall be made of GRP/ FRP/Powder coated Aluminium / cast aluminium alloy with full dust, water & vermin proof arrangement. All wire, cables must be terminated through cable lugs. The JBs shall be such that input & output termination can be made through suitable cable glands. (ii) Copper bus bars/ terminal blocks housed in the junction box with suitable termination threads conforming to IP65 standard and IEC 62208. The Hinged door shall be provided with EPDM rubber gasket to prevent water entry and single compression cable glands. (iii) Each junction box shall have high quality suitable capacity metal Oxide Varistor (MOVs)/ surge arrestor, suitable reserve blocking dides. The junction boxes shall have suitable arrangement for monitoring and disconnection for each of the group. (D) DC Distribution Board or DC Junction Box :- (i) DC Distribution Panel to receive the DC output from the array field. DC DPBs shall have sheet from enclosure of dust & vermin proof conform to IP 65 protection. The bus bars are made of copper of desired size. Suitable capacity MCBs/ MCCB shall be provided for controlling the DC power output to the PCU along with necessary surge arrestors. (E) AC Distribution Board or AC Junction Box : (i) AC Distribution Panel Board (ACDB) shall control the AC power from PCU/ inverter, and should have necessary protective devices such as MCB/ MCCBs, protection fues, surge protection devices interconnection from ACDB to mains at LT Bus bar while in grid tied mode. All switches and the circuit breakers, connectors should conform to IEC 60947, Par-I, II and III. the change-over switches, cabling work should be undertaken by the bidder as part of the project. (F) PCU/ Inverter : (i) As SPV array produces direct current electricity, it is necessary to convert this direct current into alternating current and adjust the voltage levels to match the grid voltage. Conversion shall be achieved using an electronic inverter and the associated control and protection devices. All these components of the system are termed the "Power Conditioning Unit (PCU)". In addition, the PCU shall also house MPPT ( Maximum Power Point Tracker), an interface between solar PV array & the inverter, to the power conditioning unit/ inverter should also be DG set interactive. If necessary, inverter output should be compatible with the grid frequency. Typical technical features of the inverter shall be as follows :-

-

-

-

... More
* Switching devices : IGBT/ MOSFET '* Grid Frequency Synchronization range : + 3 hz or more '*Ambient temperature considered : -20 OC to 50 OC '* Humindity : 95% Non-condensing '* Protection of enclosure : IP-20 (Minimum ) for indoor. IP-65 (Minimum) for outdoor '* Grid Frequency Tolerance range : +3 or more * Grid voltage tolerance : 20% & +15% * No-load losses : Less than 1 % of rated power '* Inverter efficiency (minimum) : 98% THD : 3% * PF : 0.9 (ii) Three phase PCU/ inverter shall be used with each power plant system (27.6/ 30kw & 20 kw). PCU/ Inverter shall be capable of complete automatic operation including wake-up, synchronization & shutdown. (iii) Built-in-meter and data logger to monitor plant performance through external computer shall be provided. (iv) The Power conditioning Units/ inverters should comply with applicable IEC/ equivalents BIS standard for efficiency measurement and environmental test as per standard codes IEC 61683/ IS 61683 and IEC 60068- 2(1,2,14,30)/ Equivalent BIS std. Make- ABB (G) INTEGRATON OF PV POWER WITH GRID : The output power from SPV would be fed to the inverter which converts DC produced by SPV array to AC and feed it into the main electricity grid after synchronization. Incase of grid failure, or low or high voltge, solar PV system shall be out pf synchronization and shall be disconnected from the grid. Once DG set comes into service PV system shall again be synchronized with DG supply and load rquirement would be met to the extent of availability of power. 4 pole isolation of inverter output with respect to the grid/ DG power connection need to be provided..

-

-

-

... More
(H) METERING : The bi-directional electronic energy meter (0.5 Class accurcy) of suitable current capacity of any reputed madke acceptable to company shall be installed for the measurement of import/ Export of envery. Meter must be provided with the necessary data cables. The meter to be supplied must be tested from any of the NABL/ BIS Accredited Testing Calibration Laboratories. it shall also comply with the requirement of CEA Regulations on "Installation and Operation of Meter". The energy meter incoming of the grid interfacing LT panel.. (J) PROTECTIONS : The sytem should be provided with all necessary protections like Earthing, Lightning, and surge proteciton. (K) CABLES : (i) Supply, lying and testing of required quantity, suitbale size, Nos of cores and material of cable from Module to AJB, AJB to inverter, Inverter to ACDB/ LtP, confirming to relevant IS, weather proof UV resistant with operting temperature unto 120 degrees, minimum rated voltage 1100V for inter connection of SPV modules including suitable size of cable lugs, male & female MC4 connection & joints etc. (ii) As the solar array for PV plant going to be installed at various locations combining 200 KWp capacity , the DC/AC cables may need to connect with each other for combined effect of plant with maximum effeciency. All connected cables shall be secured properly with bldg structure and laid undergroung as per SSR, IS codes and as directed by engineer -in- charge. (L) WARRANTY : (i) The warranty for complete system shall be for 05 years from the date of installation. (i) PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less 80% at the end of 25 years & not less than 90% at the end of 10 years. (M) DEFECT LIABILITY AND COMPREHENSIVE MAINTENANCE (i) The contractor will have 5 year Defect Liability period after completion of the work. During the DLP ocntractor will ensure generation of Minimum Average units (4 Units/KW/Day). Contractor rep and GE rep will make a joint inspection of plant on monthly basis and monthly summary of plant production will be jointly singned. (ii) The comprehensive maintenanance of the solar power plant for 5yrs during defect liability period is deemed be included in scope and contractor to quote accordingly. All required spares and periodical checking is deemed to be included.

-

-

-

... More
Note- The comprehensive maintenance for period of 5 yrs includes Maintenance & operation for trouble free operations of 200 KWp power plant at various locations of CGAE Visakahpatnam to ensure maximum Solar energy is fed to grid including following: ─ Trouble free operation of the Solar Power Plant Monitor the Performance of the Solar Power Plant by data logging.Monthly report preparation & reporting to MES on performance of Power Plant .Maintenance of Module - Periodic cleaning of module (weekly)Scheduled maintenance of Inverter.Attend to the emergency break down of the components. Frequent testing of plant equipment by 'Walk Down' checks to internal condition of equipments such as module performance, inverter test, monitorting system testing etc Careful logging of operation data and periodically processing it to determine abnormal or slowly deteriorating conditions Careful control and supervision of operation conditions. (Wide and rapid variations in voltage and frequency conditions to contribute to increased maintenance) Regulate routine maintenance work such as keeping equipment clean, cleaning of module, proper maintenance of inverters, Spare parts maintenance etc. Note : cost of defective parts /equipments is deemed to be included in the quoted rates and no extra payment shall be made to the contractor on this account for attending complaints and replacement of defective parts (iii) The rate quoted by the tenders is deemed to be included to take licence of Chief Electrical Inspectorate of SEB including all registration fee and commissioning fee complete all as specified and as directed. (All costs of SEB Registrations and approvals are deemed to be included in the contract rates) (iv)Reducing plant downtime : The contractor shall ensure the plant availability upto 99%. However, the plant availability due to grid outages will be considered only if the same are certifed by the competent authority/ CE/ CWE. Any other outages which are not attributable to the contractor and are certified by Department may also be considered.If the energy generated is less ,than a penalty of Rs 2.50 per unit shall be levied on the contractor. This is included in the quoted rates.

-

-

-

... More
(N)DESIGN/DRAWINGS/APPROVALS/DOCUMENTATION (i) The contractor shall carry out Shadow Analysis at the site and acordingly design strings & arrays layout considering optimal usage of space, material and labour. The contractor should submit the array layout drawings along with Shadow Analysis Report to GE for approval. (ii) Drawings : The contractor shall furnish the following details for approval of accepting officer prior to the commencement of the work: (a) General arrangement and dimensioned layout. (b) Schematic drawing of the plant showing the SV panels, Power conditioning inverter, Junction Boxes, AC and DC Distribution Board, metres etc. (c) Structural drawing of the mounting structure. (d) Layout of solar Power Arrays and strings. (e) Shadow analysis of the roof (iii) Drawings : On completin of project contractor shall provide Two sets of following (a) Structural drawings (b) Electrical drawings (c) O & M manuals of each equipments showing complete technical data sheet including details of specificatioms and makes. (d)Details of synchronization equipments and protection equipments (iv) Design of solar power plant including structural design of Module Mounting structure shall be vetted by IIT/NIT/ NISE/Govt institute or independebt agency approved by MNRE. The vetted design must be submitted to accepting authority for approval before commencement of work. (v) Display Board : The contractor to put up a display board of suitable size and type of a material at the project site mentioning the following : Plant Name Capacity, Location, Date of commisssiong, Warranty details, CA NO., MES Office, Power generation, Name of the contractor, Contact number for Maintenance, etc.

-

-

-

... More
Note-(a) Various Components of solar plant(inverter,panels,cables,array,junction box,etc) shall be designed to suitable to available roof areas of various buildings of subject project and to achieve maximum effeciency of system (b) Test Reports/ Certificates of PV Modules, Solar cells and Invertor to be submitted by the contractor. (c) All items/work services, material & labour required to designing,supply,erection,installation,commissioning and testing of roof top solar photovoltaic power plant shall be deemed to be included in quoted rate. (d)The required LT panels/feeder panel/MCCB breaker units as required at each bldg/block/area feeding from each inverter unit ACDB along with required cabling, other services,connections to bldg/block/area main LT panel are also deemed to be included in scope. (O)DATA ACQUISITION SYSTEM/PLANT MONITORING.- (i) On line remote Monitor system to be provided to monitor the performance of the inverter (power, array voltages, array currents & AC parameters), energy yield, temperature, irradiance level etc. and It could provides flexible interface to facilitate PC based inverter monitoring and control via GPRS modem and enternet/ethernet connection. This should have include web visualization system and data logger with integrated ethernet port. (a) Data acquisition System shall be provided for each of the solar PV plant. (b) Data Logging Provision for plant control and monitoring, time and date stamped system data logs for analysis with the high quality, including suitable PC & Printer. Metering and Instrumentation for display of systems parameters and status indication to be provided. (ii) The scope includes Remote Monitoring and data acquisition through Remote Monitoring System software at the owner/SECI location with latest software/hardware configuration and service connectivity for online/real time data monitoring/control complete to be supplied and operation and maintenance/control to be encured by the supplier. Provision for interfacing these data on owner/ SECI server and portal in future shlall be kept.

-

-

-

... More
NOTE: (i)The cost of all equipments , internet, ethernet connections, connected cables, computer, printer etc. are included in this item. (ii) Specification/details for computer minimum configuration as under: Processor i-7, RAM 4GB,Hard Disc 320 GB,with DVD Drive, 19" TFT monitor with all standard acessories . Make- Dell/HP/Lenovo Printer:- Colour laser jet printer with standard cartridge capable of printing 2000 pages minimum per cartridge. MAKE:- HP Laser Jet/Dell/Lenovo, UPS:- V Guard/Sukam/ Sinetrac.

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.