Military Engineer Services Tender
To know what Andhra Pradesh government has posted about any AP etender, Bidassist helps us to get a one-stop platform where a registered bidder can have access to the details on each and every eprocurement tender. There is no need to provide the details on the AP E-procurement website i.e. https://www.apeprocurement.gov.in as BidAssist helps us find the specific etender we're looking for. BidAassist has collated each and every Eproc Andhra Pradesh Tender on its website.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date25 Jul 2024
Closing Date6 Sep 2024
Tender Amount₹ 9,80,000
Costs
EMD
₹ 19,600Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_667937_1Bid Award Id
ViewTender No
AGE I R AND D NSTL VIZAG 8536Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Supply and fix in repair silica gel breather assembly transparent type with first fill of silica gel suitable for 1 kg breather Transformers complete including connecting with proper rubberized gasket complete including necessary GI fitting complete all as specified and directed. Make : As recommended by OEM
2
-
-
Supply and fix in repair silica gel breather assembly transparent type with first fill of silica gel suitable for 0.5 kg breather Transformers complete including connecting with proper rubberized gasket complete including necessary GI fitting complete all as specified and directed. Make : As recommended by OEM
4
-
-
Supply and Fix in replacement of LV Porcelain bushing of rating 1.1 KV, 400 to 100 Amps complete suitable for indoor/ outdoor type, step up/ step down transformers of any make/ model complete all as specifieed and as directed.
3
-
-
Supply and Fix in replacement of HV Porcelain bushing of rating 11 KV, 250 to 630 Amps complete suitable for indoor/ outdoor type, step up/ step down transformers of any make/ model complete all as specifieed and as directed.
4
-
-
Material and labour for Spray painting with Silicon Acrylic heat resistant paint of approved quality & colour to indoor/outdoor type, step up/ down transformer of capacity up to 750 KVA, installed at different locations at DRDL Kalinga after thoroughly scrapping the existing corroded paint/ rust, filling of cavities complete without disturbing/ damaging the electrical network system including writing the details such as SM/ MES No, Capacity/ Rating/ Incoming and outgoing details all as specified and directed.
6
-
-
M&L for replacement of gang opearted air-break, triple pole of load switch with dropout fuse set with 15 insulator, mounted on channels outdoor, vertical mounting type HT 11 KV , 50 Hz o rating 200 Amps, ISI marked, mechanically operated, mounted on insulators and frame work with operating mechanism worked from ground level with adequate length of GI pipe 32 mm dia medium grade and locking arrangements including Godrej (Navtal) 65 mm pad locks with two keys, complete with fuse carriers and HT fuse element havfng 10 Amp rating suitable and including necessary electric connections complete all as speciied and as directed..
2
-
-
Dis-connecting the HT 11KV VCB panel indoor/ outdoor capacity ranging from 400 to 1200 Amp of any make, Over hauling of complete panel by taking out the trolley of the breaker, opening the total mechanism of breaker checking its contact, baffle plates and other minor parts, cleaning the complete accessories carefully. Minor repairs shall be rectified, Parts/accessories shall be cleaned, the tank, baffle plates, rotating contact, upper supports, lower supports, drive assembies and all other spare parts. Reassembled after repair/ replacement of the spare parts including relay calibration, testing of existing IDTM relay as per load parameter complete all as directed by Engineer-in-Charge. Note:-(i) Repair work shall be carried out only by the authorised technician for VCB. (ii) Spare parts as required for replacement of existing worn out parts shall be measured and paid separately under appropriate items.(iii) Labour for replacement/fixing of the supply only items shall be deemed to be included in the unit rate quoted against this item.
7
-
-
Supply only Spout bushing for Indoor 11 KV upto 1200 Amps VCB complete assembly for upper side
3
-
-
Supply only Spout bushing for Indoor 11 KV upto 1200 Amps VCB complete assembly for lower side
3
-
-
800 amps. Contact plugs (upper)
4
-
-
800 amps. Contact plugs (lower)
4
-
-
Vacuum interrupter bottle for 12 KV 800 Amps Type 35409C2 indoor/Outdoor VCB 3 inch-dia Make CG/Siemens/ABB
6
-
-
Supply only 400 to 800 Amps Finger Contact assembly
3
-
-
Supply only Spring Charging motors of capacity 110 VDC Universal with gear box assembly suitable for 12VE12 VCB, UMC 14 Type as recommended by OEM complete all as specified and as directed by Engineer-in-charge. Make Ralli Wolf or equivelant
3
-
-
Closing spring assly.
3
-
-
Auxilary switch (6 no + 6 nc)
6
-
-
Closing 110 VDC (04 Nos) /Tripping coil 110 VDC (04 Nos)
8
-
-
Supply only Motor cut-off limit switch
4
-
-
Supply only Motor charged mechanasim assembly including close/trip coils and charging handle suitable for VCB 11 KV
1
-
-
Supply only Ratcet handle
6
-
-
Supply only Tripping shaft with springs
2
-
-
Supply only Closing shaft with springs
2
-
-
Supply and Fixing electronic hooter 230/110/24 Volts AC/Dc for VCB square type as required at site flush mounted of size 96mm x 96mm suitable for HT VCB 630/400 Amp including making connection with copper conductor cable of suitable size complete all as specified and as directed by Engineer-in-Charge.
7
-
-
Supply and fixing in replacement current transformer 11KV epoxy cast wound, CT of ratio 100/50/5A class-I including necessary connection etc. including testing and commissioning complete all as specified and as directed.
2
-
-
Supply and fix in replacement of Breaker control switch of capacity 25A, 3-position (Trip/ Neutral/ Close) Suttable for 11KV VCB brakears all as directed and specifed by Engr in Charge.
3
-
-
Supply only 11 Kv PT HV Back up fuse cat no 12Kv ABCNA 3.15A 38/10 as per OEM Recomendation / Make: Schnider/Bussmann
1
-
-
Preparation of old painted surface of HT Panel boards, Cable duct of any size by scrapping including hinges, doors and applying two coats of synthetic enamel paint over a coat of zinc chrome primer on new steel surfaces complete all as specified and directed.
7
-
-
Material & Labour for opening of existing APFC panel by disconecting the electric supply for cleaning and Servicing of APFC Panel including checking all connections, find out faults for required power factor,checking control wiring circuit, replacement of control wiring if required, Replacement of spares like contactors, Capacitors,CT's,PF controller and commissioning and testing of APFC panel after repair work to achieve required unity power factor including relay calibration for auto and manual function complete all as specified and as directed by Engineer-in-charge.
Note: Spares like contactors, capacitors, relays and CTs are measured and paid separately under appropriate items.
4
-
-
Supply only Power capacitor cylindrical type super heavy duty 440 V, 50 Hz , 3 phase, AC having of capacity 10 KVAR all as specified and as directed. Make : Havells/L&T/Neptune power/EPCOS
5
-
-
All as per item above here in above but of capacity 20 KVAR all as directed.
2
-
-
All as per item above here in above but of capacity 25 KVAR all as directed.
5
-
-
All as per item above here in above but of capacity 50 KVAR all as directed.
1
-
-
Supply only Power contactor suitable for 10 KVAR capacitor 440 V, 50 Hz , 3-ph, AC having of capacity 10 KVAR all as specified and as directed. Make : L&T Cat No.MO C10 (CS96156) or equivalent of Havells / Epocs/Neptune Power
5
-
-
All as per item above but suitable for 20 KVAR capacitor all as directed.Make : L&T Cat No.MO C20 (CS90021) or equivalent of Havells / Epocs/Neptune Power
2
-
-
All as per item above but suitable for 25 KVAR capacitor all as directed.Make : L&T Cat No.MO C25 (CS96322) or equivalent of Havells / Epocs/Neptune Power
5
-
-
All as per item above but suitable for 50 KVAR capacitor all as directed.Make : L&T Cat No.MO C50 (CS96324) or equivalent of Havells / Epocs/Neptune Power
1
-
-
Supply and fixing in replacement of APFC controller relay for Contactor switching with 1 CT input 415V single CT of size 96 x 96 mm suitable for Contactor Switching 8 stages with Auto programming function,smart controller all as specified and directed. Make L&T Cat No.CS90902OOOO or equivalent of Havells / Epocs/Neptune Power
1
-
-
Supply only current transformer suitable for APFC Panel for current sensing of capacity 25 A/ 5 A complete all as specified and directed by Engr in charge.Make :-Havells Cat NoQSCELMLX0002
2
-
-
M & L for taking down 11 KV grade unserviceable Pin/post insulators from the HT 2 pole/4 pole structure and S&F pin type composite insulation/silicon rubber material including one galvanishing MS spingle, nuts & washers of 150mm height, 150 mm dia for 11000 volt grade and fixing to the structure and binding of conductor all as directed.
Make: GK Electricals /Jaipuria/ ABI
3
-
-
M & L for taking down the damaged / un serviceable Lighting arresters expulsion type suitable for 11000 volts complete with all fittings,transmission class,discharge capacity 6.5 Kilo Amps Make: HTSG /JAIPURIA
2
-
-
Supply only space/ strip heaters of 1 KW, 220Volts for VCBs all as specified and directed.
3
-
-
Supply and fix single core 2.5 sqmm cable with copper conductor PVC round sheathed (flexible) industrial control for connections from CTs to relay control panel of capacity 11 KV and 433 KV including all necessary connections required, testing of relay after completing for proper functioning complete all as specified and as directed.
91
-
-
Supply and fix single core 1.5 sqmm cable with copper conductor PVC round sheathed (flexible) industrial control for connections from PTs to relay control panel of capacity 11 KV and 433 KV including all necessary connections required, testing of relay after completing for proper functioning complete all as specified and as directed.
91
-
-
Supply and fixing digital type multifuctional meter for all basic, energy and power quality parameters like Voltage, Amps, Frequancy, PF,m KW, KVA KVAR, KWH, KVAH and KVARH, with built in selector switch including square type as required at site flush mounted of size 96mm x 96mm suitable for HT VCB including making connection with copper conductor cable of suitable size complete all as specified and as directed by Engineer-in-Charge. Make L&T Cat No WL441021OOOO or Schnider
3
-
-
M&L for isolating, cutting, removing the existing damaged end termination and S&F outdoor end termination Heat shrinkable outdoor type (Earthed) suitable for HT UG cable XLPE insulated 3 Core 120 to 185 Sqmm 11KV grade including preparation complete all as directed. (Make: REPL/3M/Raychem)
2
-
-
M&L for cutting, removing the existing damaged joint and S&F straight through joint heat shrinkable type suitable for HT UG cable XLPE insulalted 3 core 120 to 185 sqmm 11000V grade including preparation complete all as directed (Make:Raychem/ REPL/ Denson).
1
-
-
Taking out the old unserviceable cable and Supply and Fixing in replacement Cross linked poly-ethylene (XLPE) insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric earthed power cables ( heavy duty) with aluminium conductor, 1100 volts grade of cross-sectional area 25 Sqmm 3.5 core conforming to IS-7098 (Part-I) laid in trenches/through pipe in road crossings/ paths /drains /ducts /floors /along poles/walls/ceilings/ equipments etc. complete supply and fixed/ laid all as specified and as directed by Engineer-in-Charge.( Note:-(i) Necessary excavation and earth work, brick protection, sand cushioning and cover and GI pipe shall be measured and paid for separately. ) Make : FortuneArt/Gloster/Havells/polycab
190
-
-
Excavation in trenches in soft/loose soil not exceeding 1.5 metre wide and not exceeding 1.5 metre depth for route of cable and getting out complete all as specified and as directed by the Engineer-in-Charge.
43.2
-
-
Returning, filling in soft/loose soil including spreading, leveling, watering and well ramming, in layers not exc 25 cm complete all as specified and as directed by the Engineer-in-Charge.
29.77
-
-
Removing of surplus soil to a distance not exc. 50 metre and depositing where directed at a level not exc.1.5 metre above the starting point complete all as specified and as directed by the Engineer-in-Charge.
13.43
-
-
M & L for dry sand cushioning and cover for protection of cable, complete all as specified and as directed by the Engineer-in-Charge. (Note: Approved local tibba dry sand after removal of vegetations, grass and other deleterious substances shall be used for sand cushioning and cover).
12.96
-
-
Supply and laying un-rainforce, precast concrete cable cover class LV, type-I of size 250 mm x 150 mm x 40mm all as specified and directed by Engineer-in-Charge.
1066.67
-
-
Material and labour for Earthing complete with galvanised steel earth plate electrode 60 x 60 cm and 6 mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m below ground level connected to galvanised GI earth strip 32 x 6 mm size by means of nuts, bolts, check nuts and washers of the galvanised iron or steel all as shown in electrical plate No 5 connected to earthing test point including watering arrangement with PCC 1:3:6 type C1 chamber, MS Funnel, Wire Guage, 50 mm thick precast RCC Coverin Type B1 including necessary excavationin any type of soil, returning, filling in, removal of surplus soil to a distance n exc 50 m, char coal and salt complete all as shoen in electrical Plate No. 3of SSR Part-1 2009 and conecting to earth test point all as specified and as directed. Note : Contractor should submit test results of earthings.
6
-
-
M&L Earthing continuity galvanised iron strip 32 x 6 mm dia or main earthing lead fixed to wall with clamps or recess or croses or buried in ground or drawn in conduits/pipe or fixed to poles or any other indicated situation for loop earthing etc as required all as specified and directed by Engr-in-Charge.
55
-
-
M&L for PCC earth pit cover suitable as per site requirement making good to disturb area complete as specified and directed by Engr-in-charge.
6
-
-
Supply and fixing in repair MCCB, AC 415 V, 50 HZ, fixed type, capacity 400 Amps, 4 Pole, 36 KA, suitable to be fixed in LT panel complete all as specified and directed Make: L&T/HAVELLS/SCHIENDER/ABB/SIEMENS/LEAGRAND
1
-
-
All as per item above but of capacity 250 amps 36 KA.
1
-
-
All as per item above but of capacity 160 amps 36 KA .
2
-
-
All as per item above but of capacity 100 amps 16 KA 3 pole.
2
-
-
GI Tubing light grade 40 mm dia for cable protection, laid under plinths/floors /roads /culverts or fixed on walls or concealed in walls or along the steel poles by means of M.S.F.I clamps with necessary bolts nuts washers etc Including taking down old u/s pipe complete all as specified.
17
-
-
Supplying and laying synthetic Rubber insulated mats 2.5 mm thick for voltage upto 11KV for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m. Including taking down of old existing mat.
6
-
-
M &L for carrying out Repairs to HT pillar box by taking down the doors, removing dents/ bends, cutting and removing rusted portions and welding new CRCA sheet of existing thickness, renewal of door gasketand refixing the doors with new hinges duly welded complete including applying two coats of synthetic enamel paint over a coat of zinc chrome primer on new steel surfaces all as specified and directed.
2
-
-
Taking out the unserviceable Temparature guage from distribution transformer of any capacity indoor/ out door type and supply and fixing New Temparataure Gauge ISI Marked complete all as directed by Engineer in charge
4
-
-