Military Engineer Services Tender
To know what Andhra Pradesh government has posted about any AP etender, Bidassist helps us to get a one-stop platform where a registered bidder can have access to the details on each and every eprocurement tender. There is no need to provide the details on the AP E-procurement website i.e. https://www.apeprocurement.gov.in as BidAssist helps us find the specific etender we're looking for. BidAassist has collated each and every Eproc Andhra Pradesh Tender on its website.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date4 Jul 2024
Closing Date1 Aug 2024
Tender Amount₹ 20,00,000
Costs
EMD
₹ 40,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_663972_1Bid Award Id
ViewTender No
8112 / E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
S & F Flame Proof Switch, Rotary Type with Termination Box in LM6, 16 Amps, Single Pole, 250 Volts including Rubber Gasket as per IS – 2149, ISI marked for ON/OFF Light, CMRI certified with cable entries complete all as specified and as directed.
6
-
-
Taking down existing serviceable Flame Proof Switch, Rotary Type with Termination Box in LM6, 16 Amps, Single Pole, 250 Volts and Refixing in new or existing location after repairs to point wiring complete all as specified and as directed.
34
-
-
S & F Flame Proof Switch Socket & Plug Combined in LM6 Cable Termination Box in LM6, 16 Amps, 250 Volts, 2P+Earth complete all as specified and as directed.
5
-
-
Taking down existing serviceable Flame Proof Switch Socket & Plug Combined in LM6 Cable Termination Box in LM6, 16 Amps, 250 Volts, 2P+Earth and Refixing in new or existing location after repairs to point wiring complete all as specified and as directed.
14
-
-
S & F Flame Proof Switch Socket & Plug Combined in LM6 Cable Termination Box in LM6, 16 Amps, 440 Volts, 3P+Earth complete all as specified and as directed.
3
-
-
S & F in repairs Flame Proof Junction Boxes 2/3/4 Way suitable for 20 mm dia ERW Steel Conduit complete all as specified and as directed.
6
-
-
S & F in repairs LED Light Fitting 2 X 16 Watt, Flame Proof, CMRI certified recommended for Gas / Vapor Group of IIA & IIIB, Zone 1 & 2 and IP 65 Protection with Die Cast Aluminium Housing with Heat Resistant Toughened Glass with LED Tube Light Fixtures, Driver, Holders, Connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable of size 1.5 Sq.mm complete all as specified and as directed.
18
-
-
S & F in repairs Flame Proof / Whether Proof Well Glass LED Light Fitting suitable for 60 Watt LED as per IS – 13947, body made out of Aluminium Alloy LM-6 Epoxy Painted with Guard, Reflector, Flameproof Clear Glass complete all accessories prewired CIMFR certified Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable of size 1.5 Sq.mm complete all as specified and as directed.
11
-
-
Taking down unserviceable 40 / 20 / 10 Watt Flame Proof / Whether Proof Tube Light Fittings and carrying out repairs as required and replacement of old unserviceable Spares with New Spares, re-assembling and re-fixing in existing position and connecting up with three core flexible copper conductor cable of size 1.5 Sq.mm complete all as specified and as directed.
279
-
-
Supply Only 18/20 W LED Master Tube Rod complete all as specified and as directed.
160
-
-
Supply Only LED Lamp 40 Watt complete all as specified and as directed.
78
-
-
Supply Only LED Lamp 22 / 24 Watt complete all as specified and as directed.
63
-
-
Supply Only LED Lamp 16 / 18 Watt complete all as specified and as directed.
60
-
-
Supply Only Holder suitable for FLP Well Glass complete all as specified and as directed.
50
-
-
S & F in repairs MCB DB, TPN, 4 Way, 415 Volts, Vertical, with DIN Channel, Double Door with 200 Amps rated bus bar suitable for mounting MCBs and provision for MCCB as incomer complete all as specified.
3
-
-
S & F MCB, FP, 40 to 63 Amps, 10 KA, 415 Volts, 50 Hz, suitable for fixing on N3 Frame complete all as specified and as directed.
14
-
-
S & F MCB, SP, 40 to 63 Amps, 10 KA, C Curve, AC, 230 Volts, 50 Hz complete all as specified and as directed.
44
-
-
S & F MCB, DP, 40 to 63 Amps, 10 KA, C Curve, AC, 230 Volts, 50 Hz complete all as specified and as directed.
22
-
-
M & L for Sub main wiring with 4 runs of single core 6 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawing through and including heavy duty PVC Conduit, 32 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type including Two runs of 6 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor including taking down old sub main wiring of any description and making good disturbed surface complete all as specified and as directed. Note: 6 runs of 6 Sq.mm & one run of 32 mm dia PVC Conduit will be measured as one unit.
60
-
-
M & L for Sub main wiring with 4 runs of single core 2.5 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawing through and including heavy duty PVC Conduit, 25 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type including Two Runs of 2.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor including taking down old sub main wiring of any description and making good disturbed surface complete all as specified and as directed. Note: 6 runs of 2.5 Sq.mm & one run of 25 mm dia PVC Conduit will be measured as one unit.
60
-
-
M & L for Sub main wiring with 4 runs of single core 1.5 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawing through and including heavy duty PVC Conduit, 25 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type including Two Runs of 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor including taking down old sub main wiring of any description and making good disturbed surface complete all as specified and as directed. Note: 6 runs of 1.5 Sq.mm & one run of 25 mm dia PVC Conduit will be measured as one unit.
60
-
-
M & L for Sub main wiring with 2 runs of single core 6 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawing through and including heavy duty PVC Conduit, 25 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type including One run of 6 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor including taking down old sub main wiring of any description and making good disturbed surface complete all as specified and as directed. Note: 3 runs of 6 Sq.mm & one run of 25 mm dia PVC Conduit will be measured as one unit.
25
-
-
M & L for Sub main wiring with 2 runs of single core 4 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawing through and including heavy duty PVC Conduit, 25 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type including One run of 4 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor including taking down old sub main wiring of any description and making good disturbed surface complete all as specified and as directed. Note: 3 runs of 4 Sq.mm & one run of 25 mm dia PVC Conduit will be measured as one unit.
80
-
-
M & L for Sub main wiring with 2 runs of single core 2.5 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawing through and including heavy duty PVC Conduit, 20 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type including One run of 2.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor including taking down old sub main wiring of any description and making good disturbed surface complete all as specified and as directed. Note: 3 runs of 2.5 Sq.mm & one run of 20 mm dia PVC Conduit will be measured as one unit.
20
-
-
M & L for Sub main wiring with 2 runs of single core 1.5 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawing through and including heavy duty PVC Conduit, 20 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type including One run of 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor including taking down old sub main wiring of any description and making good disturbed surface complete all as specified and as directed. Note: 3 runs of 1.5 Sq.mm & one run of 20 mm dia PVC Conduit will be measured as one unit.
23
-
-
S & F in repairs 36/42 W LED Power Driver for Down Lighters complete all as specified and as directed.
6
-
-
S & F in repairs Flame Proof / Whether Proof Well Glass LED Light Fitting suitable for 36 / 40 Watt LED as per IS – 13947, body made out of Aluminium Alloy LM-6 Epoxy Painted with Guard, Reflector, Flameproof Clear Glass complete all accessories prewired CIMFR certified Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable of size 1.5 Sq.mm complete all as specified and as directed.
3
-
-
Testing of Earth Resistance of existing Earth Pit as directed by the Engineer-in-Charge as and when required using Earth Resistance Testing Equipment and producing the Test Results and maintaining suitable records complete all as specified and as directed.
Note: The contractor shall be asked to carry out the Earth Test as and when required basis as per the site / user requirement. Testing of each Earth Pit shall be measured as one unit. All test results shall be entered in a suitable Register and shall be submitted to the Engineer-in-Charge. The rate quoted is deemed to be inclusive of provision of all necessary Testing Equipment as and when required basis. Nothing shall be paid extra on this account.
289
-
-
M & L for Replacement of Broken RCC Cover by new 50 mm thick Precast RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways and suitable Handle made of 10 mm dia Round Bar and other allied works complete all as specified and as directed.
17
-
-
Taking down Earth Strip from Earth Pit and testing of resistance of existing Earth Pit of Lightening Conductor for its continuity by Highly Skilled Electrician / Technician using Digital Earth Resistance Tester including checking the healthiness of earthing system and replacing Nut, Bolt with Brass Nut, Bolts as per required size and providing all Tools and Testing Apparatus including rectification of the Discontinuity by providing new Lightening Conductor or refixing the displaced existing Lightening Conductor in place as required including necessary minor repair work as required during rectification complete all as specified and as directed. Note: Testing of each Earth Pit shall be measured as One Unit and shall be carried out on priority as and when required basis. The Test Results shall be submitted to the Engineer-in-Charge and User duly signed by all concerned before claiming payment. All the materials required to complete the work at site such as wooden Plugs, Nut, Bolt, Washers, Saddles, fixing Screws etc. shall be provided by the contractor at No extra cost to the Government. Water and Salt as required in the Earth Pit shall be provided by the contractor. The rate quoted is deemed to be inclusive of provision of all necessary Testing Equipment as and when required basis and all the consumables as specified hereinabove. Nothing shall be paid extra on this account. Air Terminal, GI / Aluminium Strip shall be measured and paid separately.
60
-
-
S & F in repairs Single Pointed Air Termination Aluminium Rod, 12 mm dia and 300 mm long including necessary fasteners fixed for Lighting Protection with necessary connections to earthing etc. complete all as specified and as directed.
50
-
-
Taking out and Re-fixing of Old Serviceable Tilted Air Termination Rod of any size and type after Straightening & Dressing with and including suitable Nut, Bolts and Washers to Earth Strip complete all as specified and as directed.
20
-
-
S & F in repairs Earth Continuity Conductor or Main Earthing Lead made of Copper Strip of size 20 X 3.15mm, fixed to wall on batten or recess or chases or burried in ground or fixed to poles or any other indicated situation including drawing through GI Pipe for earthing etc. complete all as specified and as directed.
50
-
-
S & F in repairs Earth Continuity Conductor or Main Earthing Lead made of GI Strip of size 32 X 6mm, fixed to wall on batten or recess or chases or burried in ground or fixed to poles or any other indicated situation including drawing through GI Pipe for earthing etc. complete all as specified and as directed.
95
-
-
S & F in repairs Aluminium Strip of size 25 X 3 mm, fixed to walls / columns / beams etc. with Saddles or porcelain blocks of 10mm thick spaced at 1.00m centre to centre including making grooves and fixing with brass screws etc. for roof conductors and down conductors above ground complete all as specified and as directed. Note: Hylam sheet block shall be in two pieces each 10mm thick, one fixed to base with brass screws and the other fixed over it with brass screws after fixing aluminium strip in the groove provided.
480
-
-
Taking down old Copper / GI / Aluminium Strip of any size and any type from Building / Hangar [Roof / Down Conductor] / Pipe / Trench and Re-fixing the serviceable Copper / GI / Aluminium Strip of any size and type after Straightening & Dressing with and including Saddles / Insulators with Screws for fixing and making good disturbed surfaces complete all as specified and directed.
170
-
-
S & F in repairs Test Point Terminal Box of size 200 X 100 X 100mm made out of 2mm thick hot dip galvanised sheet, drilled and screwed including 6 Nos 15mm long hexagonal head screws complete with Test Point Terminal Block made of Gun Metal or Phosphorus Bronze of size 75 X 75 X 25 mm drilled and screwed including 3 Nos 8 mm dia 25 mm long hexagonal head screw complete all as specified and as directed.
32
-
-
S & F in repairs GI Funnel with Wire Mesh for Earthing Pits of existing size complete all as specified and as directed.
5
-
-
M & L for Earthing complete with CI Earth Pipe Electrode with Flanged ends, Centrifugally Cast, Class "A'', Heavy Duty, 80 mm dia all as per IS – 1536 of 2.50m length burried directly and preferably vertically in ground with top edge of the Pipe not less than 2.00 metres below Natural Ground Level connected to 32 X 6mm GI Strip [Earth Lead] and GI pipe 50 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Pipe Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the Plate by means of GI Bolts & Nuts complete all as per Electrical Plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, Drilling 400mm dia Bore Hole in any type of strata by suitable means for lowering the CI Pipe, removal of surplus soil etc. and disconnecting and taking down existing Earthing of any description complete all as specified and as directed.
10
-
-
M & L for Earthing complete with Galvanised Steel Earth Plate Electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of Plate not less than 1.50 m below normal ground level connected to 32 X 6mm GI Strip [Earth Lead] and GI pipe 50 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the Plate by means of GI Bolts & Nuts complete all as per Electrical Plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. and disconnecting and taking down existing Earthing of any description complete all as specified and as directed.
13
-
-
M & L for Earthing complete with Galvanised Steel Earth Plate Electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of Plate not less than 1.50 m below normal ground level connected to 25 x 4mm GI Strip [Earth Lead] and GI pipe 50 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the Plate by means of GI Bolts & Nuts complete all as per Electrical Plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. and disconnecting and taking down existing Earthing of any description complete all as specified and as directed.
10
-
-
M & L for Earthing complete with Galvanised Steel Earth Plate Electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of Plate not less than 1.50 m below normal ground level connected to 4mm GI Wire [Earth Lead] and GI Pipe 15 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the Plate by means of GI Bolts & Nuts complete all as per Electrical Plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. and disconnecting and taking down existing Earthing of any description complete all as specified and as directed.
1
-
-
S & F in repairs Switch Piano, Flush Button, Single Pole, One Way, 6 Amps, 230 Volts complete all as specified and as directed.
60
-
-
S & F in repairs Switch Socket Outlet, 3 & 2 Pin, Multipurpose, 6 Amps, 230 Volts, Flush Type complete all as specified and as directed.
30
-
-
S & F in repairs Switch Socket Outlet, Multipurpose, 3 pin, 16 Amps and 3 pin, 6 Amps, Flush Type, 230 Volts controlled by One Switch complete all as specified and as directed.
20
-
-
S & F in repairs Electronic Fan Regulator, Stepped Type, Flush Type, AC, 230 Volts, Single Pole complete all as specified and as directed.
5
-
-
Taking down unserviceable 40 Watt Tube Light Fitting / 20 Watt LED Tube Light Fitting and repair / replacement of old unserviceable Spares with New Spares, re-assembling and re-fixing in existing position and connecting up with twin core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm complete all as specified and as directed.
100
-
-
S & F Surface & wall mounted Energy efficient LED Tube Light Fitting, of not less than 1000 Lumens output, 5700K of cool white, with extruded Aluminium housing and robust construction with necessary acrylic diffuser & Integrated Electronic Driver, all accessories internally prewired and connecting up with twin core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm including taking down existing tube light fittings of any description and making good the disturbed surfaces to match with existing complete all as specified and as directed. Note: Light fitting shall be of PF0.95
20
-
-
S & F Surface & wall mounted Energy efficient LED Tube Light Fitting, of not less than 2000 Lumens output, 5700K of cool white, with extruded Aluminium housing and robust construction with necessary acrylic diffuser & Integrated Electronic Driver, all accessories internally prewired and connecting up with twin core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm including taking down existing tube light fittings of any description and making good the disturbed surfaces to match with existing complete all as specified and as directed. Note: Light fitting shall be of PF0.95
70
-
-
S & F in repairs Surface & wall mounted Energy efficient T8 LED Tube Light Fitting, of not less than 2000 Lumens output, 5700K of Cool White, including T8 LED Tube with extruded Aluminium housing and robust construction with necessary acrylic diffuser & Integrated Electronic Driver, all accessories internally prewired complete all as specified and as directed. Note: Light fitting shall be of PF0.95
10
-
-
S & F in repairs LED Power Driver for Downlighters suitable for 36 / 42 Watt, 240 Volts, Single Phase AC Supply, 50 Hz complete all as specified and as directed.
6
-
-
S & F in repairs LED Power Driver for Downlighters suitable for 24 Watt, 240 Volts, Single Phase AC Supply, 50 Hz complete all as specified and as directed.
6
-
-
Taking down unserviceable Post Top Lantern / Gate Light of any type / description and repair / replacement of old unserviceable Spares with New Spares, re-assembling and re-fixing in existing position and connecting up with twin core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm complete all as specified and as directed.
19
-
-
S & F Lamp Holder, Insulated Body with Back Plate, 230 Volts for Batten Fittings including LED Bulb of not less than 1000 Lumens output, 3000 K, IP40 operating voltage 90-270 Volts, AC, 50 Hz, Natural white colour complete all as specified and as directed.
5
-
-
S & F New generation, Energy Saving, Environmental Friendly, Long Life Aesthetically Designed LED Landscape Luminaire / Integral LED Bollard for Downward Lighting with High Power LED as light source, Decorative Pyramid Tripod type, of not less than 1000 Lumens output, Outdoor type, 5700 K, with Pressure Die Cast Aluminium Housing with Opal Acrylic Diffuser, IP65 Protection, electronic driver, all accessories internally prewired and connecting up with three core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm including PCC 1:2:4, Type B1 foundation for fixing complete all as specified and as directed. Note: Light fitting shall be of PF0.95. Make: Model / Catalogue No. LBLSN-10-CDL of Crompton Greaves or its Equivalent Model in Philips / Havells / Wipro / GE / Bajaj / Jaquar
6
-
-
S & F New generation, Energy Saving, Environmental Friendly, Long Life Aesthetically Designed LED Landscape Luminaire / Integral LED Bollard for Downward Lighting with High Power LED as light source, Decorative Mushroom type, of not less than 1600 Lumens output, Outdoor type, 5700 K, with Pressure Die Cast Aluminium with Opal Acrylic Diffuser, IP65 Protection, electronic driver, all accessories internally prewired and connecting up with three core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm including PCC 1:2:4, Type B1 foundation for fixing including taking down existing light fittings of any description and making good the disturbed surfaces to match with existing complete all as specified and as directed. Note: Light fitting shall be of PF0.95. Make: Model / Catalogue No. MUSHROOMBL16WLED730SSYMTOPC of Havells or its Equivalent Model in Philips / Crompton Greaves / Wipro / GE / Bajaj / Jaquar
8
-
-
S & F Square recessed mounted Flat Panel LED Ceiling Light suitable for fixing in 4' X 1' Grid False Ceiling of not less than 3600 Lumens output, 6500 K, with high transmitive diffuser for soft-light and glare free symmetrical illumination with all accessories internally prewired and including connecting up with twin core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm including taking down existing light fittings of any description and making good the disturbed surfaces to match with existing complete all as specified and as directed. Note: Light fitting shall be of PF0.95
4
-
-
S & F in repairs Factory made FRP Junction Box of size 155 X 210 X 92mm with IP 66 Protection and including MCB, SP, 16 Amps, C Curve, 240 Volts [1 Nos] and one number heavy duty Four Way Connector for incomer and outgoing cable, suitable for Pole mounting and fixed with clamps made out of 40 X 3mm flat iron with suitable nuts, bolts, gland lugs etc. duly painted with two coats of aluminium paint over a coat of red oxide zinc chrome primer complete all as specified and as directed.
2
-
-
Supply, lay, test and commissioning of 3 Core, 2.5 Sq.mm, PVC Insulated and PVC sheathed, heavy duty cable, with Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked including crimping type cable lugs, sockets etc. and connecting complete all as specified and as directed.
30
-
-
Supply, lay, test and commissioning of 3 Core, 4.0 Sq.mm, PVC Insulated and PVC sheathed, heavy duty cable, with Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked including crimping type cable lugs, sockets etc. and connecting complete all as specified and as directed.
55
-
-
S & F in repairs Switch, Modular Type, One Module, Single Pole, One Way, 6 Amps, 230 Volts complete all as specified and as directed.
28
-
-
S & F in repairs Switch, Modular Type, One Module, Single Pole, One Way, 16 Amps, 230 Volts complete all as specified and as directed.
5
-
-
S & F in repairs Socket Outlet, 3 Pin, 6 Amps, Modular Type, Two Modules, 230 Volts, complete all as specified and as directed.
10
-
-
S & F in repairs Socket Outlet, 3 pin, 16 Amps and 1 pin, 5 Amps, Modular Type, Two Modules, Multipurpose, 230 Volts complete all as specified and as directed.
9
-
-
S & F in repairs Electronic Fan Regulator, Stepped Type, Modular Type, Two Module, 120 W, AC, 230 Volts, Single Pole complete all as specified and as directed.
10
-
-
S & F in repairs Modular type Base / Grid Frame & Cover Frame for housing Modular Type Switches, Sockets and Regulators etc. of 3 Modules size, White Colour as per existing Make / Model complete all as specified and as directed.
8
-
-
S & F in repairs Modular type Base / Grid Frame & Cover Frame for housing Modular Type Switches, Sockets and Regulators etc. of 6 Modules size, White Colour as per existing Make / Model complete all as specified and as directed.
14
-
-
S & F in repairs Modular type Base / Grid Frame & Cover Frame for housing Modular Type Switches, Sockets and Regulators etc. of 8 Modules size, White Colour as per existing Make / Model complete all as specified and as directed.
10
-
-
M & L for Sub main wiring with 4 runs of single core 10 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawing through and including heavy duty PVC Conduit, 32 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type including Two runs of 10 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor including taking down old sub main wiring of any description and making good disturbed surface complete all as specified and as directed. Note: 6 runs of 10 Sq.mm & one run of 32 mm dia PVC Conduit will be measured as one unit.
20
-
-
Taking down / Dismantling the Electrical Connection from Rolling Shutter with Gearbox Motor of Capacity 1.0 HP, Electrically operated, 3 Phase, 415 Volts, removing Induction Motor and Gearbox for Reconditioning / Overhauling completely, Transporting the Induction Motor Workshop and strip opening the motor and removing the burnt out winding and cleaning the Starter Core and Rewinding with Super Enamelled Copper Conductor of suitable Gauge including Insulation, Varnishing, Packing and Testing etc., and replacement of unserviceable Ball Bearing and assembling back the Motor and re-fixing with Gearbox and necessary Electrical Connections, including replacement Base Frame with New Base Frame as per existing of Induction Motor and Gearbox Assembly, fixing with suitable Nuts, Bolts, Washers, necessary Welding / Brazing with Shutter frame with necessary alignment with Main Shaft, Speed Reducing Gearbox Assembly and Greasing, servicing and filling of New Gear Oil for smooth functioning of the system complete and testing and commissioning the Rolling Shutter complete all as specified and as directed.
4
-
-
Taking down / Dismantling the Electrical Connection from Electric Siren Motor of Capacity 1.0 HP, Electrically operated, 3 Phase, 415 Volts, removing Induction Motor for Reconditioning / Overhauling completely, Transporting the Induction Motor Workshop and strip opening the motor and removing the burnt out winding and cleaning the Starter Core and Rewinding with Super Enamelled Copper Conductor of suitable Gauge including Insulation, Varnishing, Packing and Testing etc., and replacement of unserviceable Ball Bearing and assembling back the Motor and re-fixing and necessary Electrical Connections, including replacement Base Frame with New Base Frame as per existing of Induction Motor Assembly, fixing with suitable Nuts, Bolts, Washers, necessary Welding / Brazing with Shutter frame with necessary alignment and servicing for smooth functioning of the system complete and testing and commissioning the Electric Siren complete all as specified and as directed.
2
-
-
M &L for checking the serviceability including loose contact and condition of cable terminations of all the existing MCB MCCB DBs / Flame Proof DBs at any building/any place once in three months and opening a DB serviceability register and recording building wise including obtaining users signature in the register complete all as specified and as directed.
Note: The checking shall be carried out in presence of user. One time checking including entering in the register is considered as one job.
94
-
-
S & F New generation, Energy Saving, Environmental Friendly, Long Life Aesthetically Designed with Symmetrical Light Distribution LED Landscape Luminaire / Post Top Lantern with High Power LED as light source, of not less than 4000 Lumens output, Outdoor type, 5700 K, with Spun Aluminium with Clear Cover Housing, IP65 Protection, electronic driver, all accessories internally prewired and connecting up with three core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm including taking down existing light fittings of any description and making good the disturbed surfaces to match with existing complete all as specified and as directed. Note: Light fitting shall be of PF0.95. Make: Model / Catalogue No. VICTORIAPT35WLED730PSYMTOTG of Havells or its Equivalent Model in Philips / Crompton Greaves / Wipro / GE / Bajaj / Jaquar
2
-
-
S & F Energy efficient LED Flood Light fitting, of not less than 12000 Lumens output, 6500 K, with Pressure Die Cast Aluminium Housing, IP66 Protection and Surge Protection device of 10 KV, Heat resistant Toughened Glass Cover, high power LEDs as light source, electronic driver and connecting up with three core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm including taking down existing light fittings of any description and making good the disturbed surfaces to match with existing complete all as specified and as directed. Note: Light fitting shall be of PF0.95
2
-
-
S & F Energy efficient & Long life Building Security Light Luminaire / Street Light Luminaire, of not less than 2500 Lumens output, 5700 K with Pressure Die Cast Aluminium Housing, IP66 protection, heat resistant glass cover, high power LEDs as light source, electronic driver including GI Bracket made out of 32 mm bore GI Tube, Medium Grade of size not exceeding 1.50 m in length and bent to shape required and fixed with 2 Nos of Pole fitting Clamps made out of MS Flat of size 50 X 6mm, bolts, nuts, washers and painting with two coats of aluminium paint over a coat of primer red oxide zinc chrome primer and connecting up with three core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm including taking down existing Light Fittings of any description and making good the disturbed surfaces to match with existing complete all as specified and as directed. Note: Light fitting shall be of PF0.95
6
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements