Military Engineer Services Tender
To know what Andhra Pradesh government has posted about any AP etender, Bidassist helps us to get a one-stop platform where a registered bidder can have access to the details on each and every eprocurement tender. There is no need to provide the details on the AP E-procurement website i.e. https://www.apeprocurement.gov.in as BidAssist helps us find the specific etender we're looking for. BidAassist has collated each and every Eproc Andhra Pradesh Tender on its website.
Military Engineer Services - MES Tender
Security and Emergency Services
Eprocure
Opening Date2 Sep 2024
Closing Date5 Oct 2024
Tender Amount₹ 13,09,000
Costs
EMD
₹ 26,180Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_669788_1Bid Award Id
ViewTender No
8075/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Supply of wireless addressable manual call point, integrated in red plastic housing with fire operational mark, bi-directional communication with panel and sensors, single action activation features, battery powered, resetable through keys, comply to EN45 Pt25., STQC (Govt. Of India) approved complete all as specified and directed.
Make :-MES approved products in group-I .
1
-
-
Supply of wireless Indoor siren integrated in ABC module with adapter all as specified and directed.
2
-
-
Supply of wireless signal repeater with adapter all as specified and directed.
2
-
-
Supply of external strobe siren for panel all as specified and directed.
1
-
-
Supply of AC / DC operated LED sinage all as specified and directed.
1
-
-
Supply of IP CMS SCADA Station all as specified and directed.
1
-
-
Supply of IP CMS software suite all as specified and directed.
1
-
-
Testing , Installation & Commissioning charges all as specified and directed.
1
-
-
Supply anf fixing of addressable type fire alarm panel complying BSEN-54: that supports phone number dialing using DTMF tones and meets the ademco contact ID data format accroding to the SIA DC-05 standard, 1-4 loop formats expandable upt to 8-9 loops, UP to 1000 fire detection zones 200 per panel, True peer-to-peer networking, supports intelligent/ programmable remote terminals, BMS interface, which consists of backlit display 240 x 64 menu driven graphical LCD, IP gateway and I/O drivers autolearn and loop detection 1000 event log entries, simplified logic delivers click and go configuration, approvd to EN54 parts 2 and 4, quick start and protect - a working system after an auto learn is performed optional peripheral expansion card Up to 126-254 devices per loop (protocol dependent), Up to 188,800 devices per network, networkable up to 200 nodes, circuit monitoring of locak panel circuit, simple select & honeywell, notifier, apollo discovery, argus veg a, hochiki ESP and nittan
1
-
-
Evolution protocols, single area false alram amangement facility, provision of CMS/ Ad-Net software - to monitor & control the status of the FACP- with visual & sound alerts for the fire and fault conditions- with three level multi users access. inbuilt PSTN commuinicator for remote reporting of events with CMS. PC connectivity for system supervision and operations.
1. Provision of 24- volts fault torrent network card built in diagnostics and is fully monitored for both short and open circuit faults between nodes. (to be installed in fire alram panel). The maximum number of network nodes in 200.
2. Point wiring with one power socket with switch of 5 Amps.
Make: Truesafe/ Apollo/ Cooper/ Notifier"
-
-
-
Supply, installation & testing and commissioning of GSM communicator which converts the contact ID codes of the fire alarm panel PSTN communicator for central alram monitoring: GSM communicator is special for converting the PSTN adecco contact ID codes to readable SMS notification and SIA-09 IP over GPRS network to central monitoring station (CMS). Available in 2G/3G/4G/LTE mobile network versions. Fire detection and alarm system ae to be connected with GSM module with 2/4G GSM version of 2G QUAD BADN (850/900/1800/1900 MHz) . Direct mount antenna with SMA male L-type connector -CDMA and WCDMA, 2.5 dBi gain and 850-2100/2400 MHz. IP communicator for fire alarm control panels, supports full transmision contact ID over IP SIA-DC09 event information to security monitoring station. 4/8 general alram inputs including power supply voltage monitoring via SMS messages, 800 remote control users via
1
-
-
free short call, 800 users control by GSM call or using maxim-Dallas I Button keys, configuration using standard mini-USB cable
Remote configuration and firmware upgrade, Easy installation. and diagnostic of the module via USB by using program SOFTWARE, very useful features are troubleshooting and testing of the module via USB PC; this sves time for installer and allows real time monitoring of module parameters, input/output and GSM modem status (IMEI, SIM, registration) etc.
Free configuration and diagnostic software, Free andoroid APP and WEB cloud service with software for Mobile/ Tab's/ PC's -1 set with each panel (Mobile/ Tab's/ PC's at extra cost).
2. Central alarm monitoring at security through cloud- based software (with out and ant receiver) with PC/TAB/ (PC/TAB at extra cost)
Make: compatible with Apollo/ cooper / notifier/ honeywell protocol fire alarm panel as per international communication protocol standards
-
-
-
"Supply, installation and commissioning of addressable talentum dual IR (IR2) flame dectector, Hazardous Area Model - Intrinsically safe (IS)
16571: Die cast zinc alloy
The requirements of Directive 94/9/EC, the atmosphere Expolsive ATEX
Driective have been met.
Apparatus Certificate Number: BAS02ATEX 1001
System certificate Number: Baseefa08Y0078
ExII 1G Ga Ex ia IIC T4
Zones 0,1, 2 Zone 0,1,2"
2
-
-
Supply and fixing of Multisensro (Heat & smoke) detector comprises optical smoke and thermistor temperature sensors which give both a combined singnal as well as separe heat singnal for improved false along with isolator modules as required. Positioning of multi sensor detectors as per area requirement. Functional testing of all multi sensors detectors as per area requirement. Functional testing of all multi sensors is required by all national standards around the world, including BS:5839, DIN 14675 and NFPA 72. A functional test should be carried out using can contains the test aerosol and appropriate TEST fire test tool whcih is designed for purpose and will cause no damage to the detector under test.
Operating voltage: 17-28 V DC
Communication protocol: Honeywell/ Notifier/ Apollo/ Series 90/XP95 5-9V peak to peak
Quiescent current: 500 uA averange 750 uA peak
Power - up surge current: 1mA
26
-
-
Maximum power -up time: 10s
Alaram LDE current : 3.5 mA
Remote LED current:4mA at 5V (measured across remote load)
Celan air analogue value: 23+4/-0
Alaram level analogue value: 55
Alaram indicator: 2 colourless Light emitting Diodes (LEDs)' illuminated red in alaram optional remote LED
Dimensions: 100 mm diameter 50mm height 58mm (height in base)
Weight: Detector: 105g Detecor in base: 160 g
materials: Housing: white polycarbonate V-o rated to UL94 terminals: Nickel plated stainless steel
Smoke element only: chamber configuration: Horizontal optical bench housing infra- red emitter and sensor, arranged radially to detect forwared scattered light.
Sensor: Silicon PIN photo- diode
Make: Apollo./ cooper/ notifier
-
-
-
"Supply and fixing of loop sounder visual indicator are available when it is being controlled by the full core protocol with the fire control panel programmed accordingly. These are indentical to the sounder visual indicator base but eh open area sounder visual indicator is a wall mounted stand alone device that produces a higher sound output of up to 100dB (A).
Make: Apollo/ Cooper/ Notifier"
2
-
-
Supply and fixing of addressable dual action manual pull station: the addressable manual pull station is a die-cast pull station used for a variety of applications focusing mainly on fire alarm systems. The pull station is a single action switch. The pull station has a 10 amps snap action switch and a dedicated terminal block for the ease of wire connections. All of the metal is completely coated to inhibit corrosion and provide for a uniform and quality finish. The manula pull station has a hex key rest. Make: Apollo/ Cooper/ Notifier
4
-
-
Supply and fixing 2 core 1.5 sqmm copper cable: 2 core, 1.5 Sqmm, through rigid PVC conduits, high conductivity annealed bare electrolytic copper conductor 650/1100 v grade, pvc insulated, pair twisted & screened, flexible, both inner and outer FR/FRLS PVC sheathed with proper pair identification. 1.2 strandard: As per IS 1554, part-I & IS 5831 latest and any other relevant.
Make : Polycab/ KEI/ Havells
530
-
-
Supply and fixing of 20 sqmm, rigid PVC conduit inclusive of all the necessary fittings like Bends, Tee's Elblow on wall/ Trenches all as specified and directed.
Make: Finolex/ Sudhakar/ Kalinga
450
-
-
Supply and fix voltage stabilzer for automatic operation, single phase naturally air- cooled indoor type & designed for input variation between 170V and 250V with output voltage stabilized at 230V with accuracy of 2.5 % and of capacity 2.0 KVA complete all as specified and directed.
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements