Military Engineer Services Tender

To know what Andhra Pradesh government has posted about any AP etender, Bidassist helps us to get a one-stop platform where a registered bidder can have access to the details on each and every eprocurement tender. There is no need to provide the details on the AP E-procurement website i.e. https://www.apeprocurement.gov.in as BidAssist helps us find the specific etender we're looking for. BidAassist has collated each and every Eproc Andhra Pradesh Tender on its website.

Military Engineer Services - MES Tender

Works
Civil And Construction
Electrical and Electronics
Water Storage And Supply
Electrical Works
Eprocure
Opening Date21 Jun 2024
Closing Date11 Jul 2024
Tender Amount₹ 8,80,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply and filling in and speading unwashed river sand for cushioning and covering the under ground cables in trenches and punning to provide required cover complete all as specified in SSR Part-I and as directed.

13

-

-

... More
Supply and lay cable cover for LT Cable Class LV,type 1 , flat size 250mmx150mm x 40 mm.

1067

-

-

... More
M&L for GI pipe 25 mm dia "Medium Grade" laid in trenches floors/on pole/road for cable protection with all fittings complete all as specified and directed. Note :- Excavation, earth work, cable protection, sand fillings, cable joint shall be measured and paid separately under respective items of schedule.

100

-

-

... More
All as per Srl Item No. 6 here-in-before but 40 mm dia

100

-

-

... More
All as per Srl Item No. 6 here-in-before but 50 mm dia

100

-

-

... More
All as per Srl Item No. 6 here-in-before but 80 mm dia

60

-

-

... More
All as per Srl Item No. 6 here-in-before but 100 mm dia

50

-

-

... More
M&L for XLPE insulated, LT armoured electric cable with aluminium standared conductor 1100 volts grade, cross-sectional area 16 sqmm, 4.00 core laid in trenches/pipes/ducts/wall/boarings with necessary cable lugs and glands,nuts,bolts and washers etc. and testing complete all as specified and directed. Note :- Excavation, earth work, cable protection, sand fillings, cable joint shall be measured and paid separately under respective items of schedule.

100

-

-

... More
All as per Srl Item No. 11 here-in-before but cross-sectional area 25 Sqmm x 3.5 core

100

-

-

... More
S&F in repairs Sluice Valve Class PN 1.6 80 mm dia with iron wheel head, and all as directed by Engineer - in-Charge:

1

-

-

... More
S&F in repairs gun metal globe or gate valves with iron wheel head, screwed both ends for iron pipe of sizes 50 mm dia complete all as specified and as directed by Engineer - in-Charge:

6

-

-

... More
S&F in repairs gun metal globe or gate valves with iron wheel head, screwed both ends for iron pipe of sizes 40 mm dia complete all as specified and as directed by Engineer - in-Charge:

8

-

-

... More
S&F in repair gun metal globe or gate valves with iron wheel head, screwed both ends for iron pipe of sizes 25 mm dia complete all as specified and as directed by Engineer - in-Charge:

8

-

-

... More
S&F in repairs gun metal globe or gate valves with iron wheel head, screwed both ends for iron pipe of sizes 20 mm dia complete all as specified and as directed by Engineer - in-Charge:

8

-

-

... More
M&L for dismantling defective induction motor of 5 HP capacity any make 415 Volt of any duty or any class of insulation from the bed duly coupled with pump, transporting to work shop, removing burnt out winding from stator, rotor and rewinding with suitable gauge super enameled copper wire of approved make and replacing driven end and non driven end bearings, insulation materials, varnishing, heating reassembling, testing and commissioning for the following capacities all as directed. Notes :- Motor removed for rewinding shall be overhauled completely and the quoted rate shall be deemed to be inclusive for the same.

2

-

-

... More
Supply and fix in repairs for Star Delta starter for Motor Pump for up to 5 HP Capacity including 3 phase prventer complete all as specified and as directed by Engr-in-Charge.

2

-

-

... More
Dismantling damage and broken valve chamber of size (1200x1200x900)mm including U/S rusted MS cover complete without disturbing the existing pipe lines valves and provide valve chamber including necessary earth work in any type of soil PCC 1:1.5:3 in base concrete brick work in cement mortar (1:6) with 10 mm thick plaster internally and 15mm thick externally in cement mortar (1:4) 6mm thick MS sheet cover with hinges and locking arrangements fixed to angle iron frame made out of 50x50x6mm MS complete with 2 coat of synthatic enameled paint over a coat of red oxied on all steel work and 2 coats of white washing on plastered surface of valve chamber of any sizes complete all as specified and as directed by Engr - in- charge.

2

-

-

... More
Dismantling damage and broken valve chamber of size (450x450x450)mm including U/S rusted MS cover complete without disturbing the existing pipe lines valves and provide valve chamber including necessary earth work in any type of soil PCC 1:1.5:3 in base concrete brick work in cement mortar (1:6) with 10mm thick plaster internally and 15mm thick externally in cement mortar (1:4) 6mm thick MS sheet cover with hinges and locking arrangements fixed to angle iron frame made out of 50x50x6mm MS complete with 2 coat of synthatic enameled paint over a coat of red oxied on all steel work and 2 coats of white washing on plastered surface of valve chamber of any sizes complete all as specified and as directed by Engr - in- charge.

2

-

-

... More
Dismantling damage and broken valve chamber of size (900x900x900)mm including U/S rusted MS cover complete without disturbing the existing pipe lines valves and provide valve chamber including necessary earth work in any type of soil PCC 1:1.5:3 in base concrete brick work in cement mortar (1:6) with 10mm thick plaster internally and 15mm thick externally in cement mortar (1:4) 6mm thick MS sheet cover with hinges and locking arrangements fixed to angle iron frame made out of 50x50x6mm MS complete with 2 coat of synthatic enameled paint over a coat of red oxied on all steel work and 2 coats of white washing on plastered surface of valve chamber of any sizes complete all as specified and as directed by Engr - in- charge.

2

-

-

... More
Cleaning of underground sump of capacity 10K Litre by pumping out water from U/G sump by pump set as directed at site and taking out the remaining water at bottom by buckets manually as required . Taking out soil, sand and mud settled at the bottom and finally cleaning with bleaching, marking of date of cleaning on outsuide of sump complete all as specified and as directed by Engr - in- charge.

2

-

-

... More
Cleaning of underground sump of capacity 20K Litre by pumping out water from U/G sump by pump set as directed at site and taking out the remaining water at bottom by buckets manually as required . Taking out soil, sand and mud settled at the bottom and finally cleaning with bleaching, marking of date of cleaning on outsuide of sump complete all as specified and as directed by Engr - in- charge.

2

-

-

... More
S&F in repairs MCCB 100 Amp capacity, 3 Pole, 415 Volt grade, rupturing capacity 16kA, with fixed thermal and magnetic setting, including making incoming and outgoing connections using thimbles / lugs of appropriate size, complete all as specified.

2

-

-

... More
S&F in repairs MCCB 63 Amp capacity, 4 Pole, 415Volt grade, rupturing capacity 16kA, with fixed thermal and magnetic setting, including making incoming and outgoing connections using thimbles / lugs of appropriate size, complete all as specified.

2

-

-

... More
M&L and services for taking sample water in sterlised bottles from UG Sump for Analysis of water for the following parameters and obtaining sample test report from Govt Recognized Laboratories: (i) Physio Chemical Analysis of Water ( Colour , odour , pH Total solids, Dissolved Solids, Permanent hardness, temporary Hardness, Ammonia feree and salinbe, Ammonia Albuminoidal, Nitrites, Nitreates, Oxygen absorption at 15 Min, Iron , Fluoride) (ii) Microbiological Analysis ( Totral Choliforms , Eschirrchea Coli) Notes : (i) A certificate of approval / certification of Lab by Govt Of India / State Govt shall be submitted by the contractor to the deptt. (ii) Sample shall be submitted to the Labortory within 24 Hrs of collection of sample

4

-

-

... More
Supply, install, testing (as per IEC 61439-1) and commisioning of LT feeder piller box of suitable size as per relevant IS, CPRI approved, cubical floor mounted outdoor canopy type, factory made, totally enclosed, dust and vermin proof made out of 3 mm thick MS sheet duly powder coated both side in and out, having suitable locking arrangments both at front and rear sides, aluminium busbar of 270Amps capacity duly drilled holes for connections and mounted on epoxy based post insulators for 3 phase, 4 wire, 500V, 50Hz AC supply, including hibling, cable entry boxes, cable gland, suitable angle iron framed support (bottom portion of the panel), grouted in foundation in PCC 1:2:4 type B1 using 20mm graded stone aggregates including old unserviceable LT feeder piller complete all as specified and as directed housing and with the following switchgears: Incoming (a) MCCB 4Pole, 415V, 200 Amps, 35KA-01Nos. Outgoing (a) MCCB 4Pole, 415V, 100 Amps, 25KA - 01 Nos. (b) MCCB 4Pole, 415V, 63 Amps, 25KA - 03 Nos. (c) Digital multi-function meter 01Nos (d) MCB TPN, 415V, 32Amps, 10KA - 02 Nos. (e) Phase indicator lamps (RYB) set of 3-01set

1

-

-

... More
S&F in repair of solar type kitchen chimany, dismentaling existing solar Chimeny from top of building and checking of motor, servicing/overhauling of motor, replacement of warn out parts, and reinstallation of solar chimany after completion of work and testing complete all as specified and directed by Engr-in-Charge.

1

-

-

... More
M & L for repairing of broken earthing pits chamber with PCC (1:3:6) type C-1 with RCC cover (1:2:4) type B-0, 40 mm thick reinforced with 6 mm dia bar, 3 Nos. both way, funnel with wire mesh for watering pipe including Painting with White cement colour (Red/Green/Yellow) of earthing pits of diffirent colour as per Earthing type (Chemical/Lightening Protection and Conventional ) all as directed by Engr-in-charge.

5

-

-

... More
M & L for repairing of Broken Foundations of Monolock Pumps and LT Panel Board including raising of heights of panels as possible at site with PCC (1:3:6) type C-1 and painting the foundations with cement base paint or as per existing pattern complete all as directed by Engr-in-Chrage at site.

2

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.