Military Engineer Services Tender

To know what Andhra Pradesh government has posted about any AP etender, Bidassist helps us to get a one-stop platform where a registered bidder can have access to the details on each and every eprocurement tender. There is no need to provide the details on the AP E-procurement website i.e. https://www.apeprocurement.gov.in as BidAssist helps us find the specific etender we're looking for. BidAassist has collated each and every Eproc Andhra Pradesh Tender on its website.

Military Engineer Services - MES Tender

Works
Eprocure
Opening Date2 Jan 2025
Closing Date18 Feb 2025
Tender Amount₹ 3,39,50,00,000 
Notes
Download

Costs

Summary

Provn Of Infrastructure For Certain Technical Buildings Soil Stabilisation And Pavement

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Get the Best Price For TMT
Starting from
₹51,000/MT*
Andhra Pradesh
Documents
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Design, Procurement and erection and commissioning of Pre-engineered Bldg steel structure for Technical Hangar made up with Hot Rolled Section confirming to IS 2062 E 250 (Fe 410W)A and Cold formed Sections (Purlin & Girts) of ASTM A653M SS Grade 340 Class 1 Coating : Z 120 and Sheeting Panels of Aluzinc coated steel pre painted confirming ASTM A792M Grade 340 Class 1 coating including Gantry girder to full width/ span for crane, electro mechanical operated sliding doors with steel frames, bird proofing and connected accessories and RCC M-30 Col with Brick wall built in CM 1:6 and plastering both sides with 2 coat weather coat arcylic paint on external wall and 2 coat OBD in internal and 400mm thick PQC Flooring to achieve flexural strength 45Kg/cm2 in 28 days over one layer of high density polythene sheet (virgin quality) 400micron thick and of weight not less than 380 g/sqm over 10mm thick sand cushoning over 100 mm thick dry lean concrete with minimum 150kg/cum of cement and compressive strength not less than 10mpa in 7days over 225mm (compacted thickness) WMM in 3 layers of 75mm each layer over 300mm thick granular sub base grading V with broken boulders of trap/granite stone in 2 layers as per Design obtained from E-in-C's branch vide letter No 90176/Visakhapatnam/133/E2W(RI-1) dated 18 Jul 2018 including provision of contraction, construction and expansion joints, filler board, sealant primer, joint sealant, backer rod , deponding strip as per drawing and Providing and application of self smoothing epoxy topping 4 mm over PQC flooring as complete all as specified and as directed.

1

-

-

... More
Design, Procurement and Construction of Annex Bldg for Technical Hangar including with permanent specifications Including Pile Foundation RCC framed structure in RCC M30 grade concrete, PCC Block Masonry, powder coated Aluminum windows with deco grill RCC roof with slope 1:30 provided with water proofing treatement, including internal Water supply, internal electric supply, complete all as specified and as directed.

-

-

-

... More
Design, Construction, erection and commissioning of pre-engineered building steel structure for Sun Shelters made up of hot rolled section confirming to IS-2062 E 250 (Fe-410WA) and cold formed sections (Purlin & Girts of ASTM A653M SS Grade-340 Class-1 coating Z-120 and sheeting panels of aluzinc coated steel pre painted conforming to ASTM A792M Grade-340 Class-1 coating AZM-150 etc. complete all as specified and as shown on drawings and as directed.

1

-

-

... More
Notes for Sl No. 5:

-

-

-

... More
(i) The contractor shall be responsible for design of foundation and all RCC members from qualified Structural Designers as per CA Conditions and approved by Accepting Officers duly vetted by any of the IITs as provided in the Contract Agreement and Carrying out structural design (PEB structure) based on independent soil investigation as per guidelines mentioned on DBR (Design Based Report) included in the tender documents from the approved structural designers, vetting the design from any of the approved IITs, getting approval from the Accepting Officer and submission of bill of quantities, yardsticks etc.

-

-

-

... More
(ii) The architectural drawings enclosed with contract documents are the guidance for designing the structural members. The Plinth Area shall remain same and any minor changes which are technically/ functionally required as per user requirement at ground shall be executed by the contractor without any extra cost.

-

-

-

... More
(iii) Cost of any raising of ground/cutting required for fixing MGL and raising of plinth level, the cost of earth work with all connecting works (RCC/Masonry and finishes) as directed shall be deemed to be included in the quoted rate.

-

-

-

... More
(iv) Construction of buildings and structures under this schedule shall be commenced on completion of area development. Excavation of foundation shall be reckoned from made up ground level (MGL) as indicated in structural drawings.

-

-

-

... More
(v) Earth work, excavation, returning filling in, disposal of surplus soil to a distance as specified, filling under floors (filled earth/moorum) with reference to MGL as shown in the drawings for building portion is deemed to be included in the scope of lump sum quoted against these items and nothing extra shall be paid. Please note that the quantity of moorum items specified in BoQ is only applicable for Soil stabilisation and Pavement portion only and not applicable for Lumpsum portion of Sunshelter bldg.

-

-

-

... More
(vi) The contractor shall carry out cutting/filling between MGL & NGL (Natural Ground Level), Site clearance and surface excavation without any additional cost, deemed to be included in quoted rate and these items shall not be measured and paid separately under Schedule 'A' Part-II for Sunshelter bldg.

-

-

-

... More
(vii) Internal water supply & internal electric supply are not inclusive of this item and will be measured and paid for under relevant schedules.

-

-

-

... More
(viii) The contractor shall facilitate the Third Party Inspection Team appointed by the Accepting Officer.

-

-

-

... More
Design, Procurement and Construction of AC Plant Rooms including pile foundation with permanent specifications RCC framed structure in RCC M30 grade concrete, PCC solid Block Masonry, powder coated Aluminum windows with deco grill RCC roof with slope 1:30 provided with water proofing treatement, including internal Water supply, internal electric supply including construction of Ramp & open platform complete all as specified and as directed.

2

-

-

... More
Design, Procurement and Construction of Utility Room for Air Craft Washing Platform including pile foundation with permanent specifications RCC framed structure in RCC M30 grade concrete , PCC solid Block Masonry, powder coated Aluminum windows with deco grill RCC roof with slope 1:30 provided with water proofing treatement, including internal Water supply, internal electric supply including construction of platform for water tank complete all as specified and as directed.

1

-

-

... More
Design, Procurement and Construction of Storage Preservation and De-Preservation of Buildings (S/S) including pile foundation with permanent specifications RCC framed structure in RCC M30 grade concrete, PCC solid Block Masonry, powder coated Aluminum windows with deco grill RCC roof with slope 1:30 provided with water proofing treatement, including internal Water supply, internal electric supply including construction of Ramp complete all as specified and as directed.

1

-

-

... More
Design, Procurement and Construction of AC Plant Room for Storage Preservation and De-Preservation of Buildings (S/S) including pile foundation with permanent specifications RCC framed structure in RCC M30 grade concrete , PCC solid Block Masonry, powder coated Aluminum windows with deco grill RCC roof with slope 1:30 provided with water proofing treatement, including internal Water supply, internal electric supply including construction of Ramp and open platform complete all as specified and as directed.

1

-

-

... More
Design, Procurement and Construction of Battery Charging, Ext Charging, for Fire fighting equipments, special charging station (S/S) including pile foundation with permanent specifications RCC framed structure in RCC M30 grade concrete, PCC solid Block Masonry, powder coated Aluminum windows with deco grill RCC roof with slope 1:30 provided with water proofing treatement, including internal Water supply, internal electric supply including construction of Ramp and acid proof tile for floor complete all as specified and as directed.

1

-

-

... More
Design, Procurement and Construction of Pump House for Regular water supply (S/S) including pile foundation with permanent specifications RCC framed structure in RCC M30 grade concrete, PCC solid Block Masonry, powder coated Aluminum windows with deco grill RCC roof with slope 1:30 provided with water proofing treatement, including internal Water supply, internal electric supply including construction of Ramp complete all as specified and as directed.

1

-

-

... More
Design, Procurement and Construction of Pump House (S/S) For Fighting including pile foundation with permanent specifications RCC framed structure in RCC M30 grade concrete ,PCC solid Block Masonry, powder coated Aluminum windows with deco grill RCC roof with slope 1:30 provided with water proofing treatement ,including internal Water supply, internal electric supply including construction of Ramp complete all as specified and as directed.

2

-

-

... More
Design, Procurement and Construction of POL Store (S/S) including pile foundation with permanent specifications RCC framed structure in RCC M30 grade concrete , PCC solid Block Masonry, powder coated Aluminum windows with deco grill RCC roof with slope 1:30 provided with water proofing treatement, including internal Water supply, internal electric supply including construction of Ramp and raised Hard standing in front of POL Store complete all as specified and as directed.

1

-

-

... More
Design, Procurement and Construction of Sub Station Building Regular For Proposed Assets including pile foundation with permanent specifications RCC framed structure in RCC M30 grade concrete ,PCC solid Block Masonry, powder coated Aluminum windows with deco grill RCC roof with slope 1:30 provided with water proofing treatement, including internal Water supply, internal electric supply including construction of Ramp complete all as specified and as directed.

1

-

-

... More
Design, Procurement and Construction of Static Water Tank 125 KL Capacity For Fire Fighting in RCC in M30 grade concrete, RCC roof including Pile Foundation all as shown in site plan and all Inside accessories shall be provided as per standard practice/drg complete all as specified and as directed.

2

-

-

... More
Design, Procurement and Construction of Semi Underground Sump for Fire Hydrant System of the Proposed Buildings at INS Dega in RCC in M30 grade concrete, RCC roof including Pile foundation etc all as shown in site plan and all Inside accessories shall be provided as per standard practice/drg complete all as specified and as directed.

1

-

-

... More
Design, Procurement and Construction of UG Sump 6.5 Lakh Litres for Regular Water Supply in RCC M30 grade concrete, RCC roof etc., including Pile Foundation all as shown in site plan and all Inside accessories shall be provided as per standard practice/drg complete all as specified and as directed.

2

-

-

... More
Design, Procurement and erection and commissioning of Pre-engineered Bldg steel structure for Maintenance Hangar (As per Drawings) made up with Hot Rolled Section confirming to IS 2062 E 250 (Fe 410W)A and Cold formed Sections (Purlin & Girts of ASTM A653M SS Grade 340 Class 1 Coating : Z 120 and Sheeting Panels of Aluzinc coated steel pre painted confirming ASTM A792M Grade 340 Class 1 coating including Gantry girder to full width/ span for crane, electro mechanical operated sliding doors with steel frames, bird proofing and connected accessories including pile foundation and RCC M-30 Col with Brick wall built in CM 1:6 and plastering both sides with 2 coat weather coat arcylic paint on external wall and 2 coat OBD in internal and 400mm thk PQC Flooring to achieve flexural strength 45Kg/cm2 in 28 days over one layer of high density polythene sheet (virgin quality) 400micron thick and of weight not less than 380g/sqm over 10mm thick sand cushoning over 100 mm thick dry lean concrete with min 150kg/cum of cement and compressive strength not less than 10mpa in 7days over 225mm (compacted thickness) WMM in 3 layers of 75 mm each layer over 300 mm thick granular sub base grading V with broken boulders of trap/granite stone in 2 layers as per Design obtained from E-in-C's branch vide letter No 90176/Visakhapatnam/133/E2W(RI-1) dated 18 Jul 2018 including provision of contraction, construction and expansion joints, filler board, sealant primer, joint sealant, backer rod, deponding strip as per drawing and Providing and application of self smoothing epoxy topping 4mm over PQC flooring complete all as specified and as directed.

1

-

-

... More
Design, Procurement and Construction of Air Stores complex (D/S) including pile foundation with permanent specifications RCC framed structure in RCC M30 grade concrete ,PCC solid Block Masonry, powder coated Aluminum windows with deco grill RCC roof with slope 1:30 provided with water proofing treatement, including internal Water supply, internal electric supply including construction of Ramp and raised Hard standing in front of Air Stores Complex complete all as specified and as directed.

-

-

-

... More
Design, Procurement and Construction of Air Stores complex (D/S) including pile foundation with permanent specifications RCC framed structure in RCC M30 grade concrete, PCC solid Block Masonry, powder coated Aluminum windows with deco grill RCC roof with slope 1:30 provided with water proofing treatement, including internal Water supply, internal electric supply including construction of Ramp and raised Hard standing infront of Air Stores Complex complete all as specified and as directed.

1

-

-

... More
Design, Procurement and Construction of Substation Bldg including pile foundation with permanent specifications RCC framed structure in RCC M30 grade concrete ,PCC solid Block Masonry, powder coated Aluminum windows with deco grill RCC roof with slope 1:30 provided with water proofing treatement, including internal Water supply, internal electric supply , incl construction of Ramp & open platform complete all as specified and as directed.

1

-

-

... More
Design, Procurement and Construction of Compresser Room including pile foundation with permanent specifications RCC framed structure in RCC M30 grade concrete, PCC Solid Block Masonry, powder coated Aluminum windows with deco grill RCC roof with slope 1:30 provided with water proofing treatement, including internal Water supply, internal electric supply, including construction of Ramp & open platform complete all as specified and as directed.

1

-

-

... More
Construction of RCC Septic tank for 150 users designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix n Walls, Base slab, Baffle walls and Roof slab including beams etc., with Vent shaft, manhole openings with cover connection etc., complete all as specified and as shown in drawing and as directed

1

-

-

... More
Construction of RCC Septic tank for 50 users designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix n Walls, Base slab, Baffle walls and Roof slab including beams etc., with Vent shaft, manhole openings with cover connection etc., complete all as specified and as shown in drawing and as directed

1

-

-

... More
Construction of LLDPE septic tank 10 users designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, vent shaft, connection etc., complete all as specified and as shown in drawing and as directed

2

-

-

... More
Construction of LLDPE septic tank 25 users designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, vent shaft, connection etc., complete all as specified and as shown in drawing and as directed

1

-

-

... More
Construction of Soakage wells upto 25 users excavation, in any type of soil, foundation in PCC 1:4:8 walls of honey combed masonry with RCC cover slab in M30 cover, interconnecting pipes of RCC complete filled with brick bats complete all as specified and as shown in drawing and as directed.

3

-

-

... More
Construction of Soakage wells upto 50 users excavation, in any type of soil, foundation in PCC 1:4:8 walls of honey combed masonry with RCC cover slab in M30 cover, interconnecting pipes of RCC complete filled with brick bats complete all as specified and as shown in drawing and as directed.

4

-

-

... More
Schedule "A" Part – II to Schedule "A" Part – XV: NOTE: Schedule "A" Part – II to Part – XV are prepriced by MES. Bidders shall insert their Lumpsum amount in Green coloured field under Column - 6 only

-

-

-

... More
Lumpsum price worked out by the contractor for "SITE CLEARANCE & AREA DEVELOPMENT/ EARTH WORK/EXCAVATION", as listed in Schedule "A" Part – II

1

342701745

-

... More
Lumpsum price worked out by the contractor for "SEWAGE DISPOSAL ", as listed in Schedule "A" Part – III

1

6021141

-

... More
Lumpsum price worked out by the contractor for "EXTERNAL WATER SUPPLY", as listed in Schedule "A" Part – IV

1

2145865

-

... More
Lumpsum price worked out by the contractor for "EXTERNAL ELECTRIFICATION", as listed in Schedule "A" Part – V

1

22215738

-

... More
Lumpsum price worked out by the contractor for "ROADS & CULVERT", as listed in Schedule "A" Part – VI

1

30425463

-

... More
Lumpsum price worked out by the contractor for "AREA DRAINAGE", as listed in Schedule "A" Part – VII

1

43923182

-

... More
Lumpsum price worked out by the contractor for "FIRE FIGHTING/ FIRE ALARM SYSTEM", as listed in Schedule "A" Part – VIII

1

9301512

-

... More
Lumpsum price worked out by the contractor for ""LIGHTENING PROTECTION ", as listed in Schedule "A" Part – IX

1

1806736

-

... More
Lumpsum price worked out by the contractor for "COOLING APPLIANCES", as listed in Schedule "A" Part – X

1

1823236

-

... More
Lumpsum price worked out by the contractor for "LIFTS & DG SET", as listed in Schedule "A" Part – XI

1

115020

-

... More
Lumpsum price worked out by the contractor for "INTERNAL ELECTRIFICATION", as listed in Schedule "A" Part – XII

1

2336436

-

... More
Lumpsum price worked out by the contractor for "INTERNAL WATER SUPPLY", as listed in Schedule "A" Part – XIII

1

927284

-

... More
Lumpsum price worked out by the contractor for "RETAINING WALL", as listed in Schedule "A" Part – XIV

1

51127661

-

... More
Schedule "A" Part - XV: [Miscellaneous Items]

-

-

-

... More
SOIL STABILIZATION/PAVEMENT/PVD:

-

-

-

... More
Excavation of compacted surcharge loading (moorum) by mechanical means (Hydraulic excavator) up to 4.5m deep and getting out including dressing of sides and ramming of bottoms including dewatering etc. for sub-surface drainage complete all as specified and as directed.

230987

-

-

... More
Labour only for moorum filling in embankment with proper side slope as per drawing (For subgrade and earthen shoulders), spread, levelled, rolled and consolidated with 8 to 12 Tonne static road rollers and vibratory roller in layers not exc. 50 cm thickness to a height not exc. 2.0m from MGL maintaining a minimum degree of compaction of 98% of modified proctor density including watering and necessary T&P all as per cross section details shown on drawing complete all as specified and as directed.

109315

-

-

... More
M&L for moorum filling in embankment with proper side slope as per drawing (For surcharge preloading), spread, levelled, rolled and consolidated with 8 to 12 Tonne static road rollers and vibratory roller in layers not exc. 50 cm thickness to a height exc. 2.0m but not exc. 4.5m from MGL maintaining a minimum degree of compaction of 98% of modified proctor density including watering and necessary T&P all as per cross section details shown on drawing complete all as specified and as directed. Notes for Item Nos.10 & 11: (i) Moorum obtained from the excavation of compacted surcharge loading shall be used. (ii) Compacted thickness will be measured for payment. (iii) These rate are inclusive of forming embankment. (iv) Moorum shall have liquid limit (LL) less than 35%, plasticity index (PI) less than 15%. (v) Moorum shall be of maximum dry density not less than 2g/cm3.

121676

-

-

... More
M&L for moorum filling in embankment with proper side slope as per drawing (For surcharge preloading in bottom layer 500 mm depth above granular sand blanket), spread, levelled, rolled and consolidated with 8 to 12 Tonne static road rollers and vibratory roller in layers not exc. 25 cm thickness to a height not exc. 2.0m from MGL maintaining a minimum degree of compaction of 98% of modified proctor density including watering and necessary T&P all as per cross section details shown on drawing complete all as specified and as directed.

88606

-

-

... More
M&L for moorum filling in embankment with proper side slope as per drawing (For backfill on sides of granular sand blanket), spread, levelled, rolled and consolidated with 8 to 12 Tonne static road rollers and vibratory roller in layers not exc. 50 cm thickness to a height exc. 2.0m but not exc. 4.50m from MGL maintaining a minimum degree of compaction of 98% of modified proctor density including watering and necessary T&P all as per cross section details shown on drawing complete all as specified and as directed. Notes for Item Nos.12 & 13: (i) Moorum shall be brought from outside MoD land and the lead for the same will be measured and paid separately. (ii) Compacted thickness will be measured for payment. (iii) These rate are inclusive of forming embankment. (iv) Moorum shall have liquid limit (LL) less than 35%, plasticity index (PI) less than 15%. (v) Moorum shall be of maximum dry density not less than 2g/cm3.

101716

-

-

... More
Depositing, spreading and levelling in layers not exc. 15 cm thick of smaller gradation filter material around and over 630mm HDPE pipes manually without damage to drainage pipe (As per MORTH Table 300-3 (Class-1)) in trenches for sub surface drain including all necessary arrangement for maintaining geotextile on vertical position complete all as specified and as directed.

1182

-

-

... More
Depositing, spreading and levelling in layers not exc. 15 cm thick of larger gradation filter material around and over 630mm HDPE pipes manually without damage to drainage pipe (As per MORTH Table 300-3 (Class-3)) in trenches for sub surface drain including all necessary arrangement for maintaining geotextile on vertical position complete all as specified and as directed.

596

-

-

... More
M&L for river sand filling in pavements, Taxi links, (Granular sand blanket measuring 500mm thick) including watering, levelling, rolling and consolidating the surface by heavy compaction (IS-2720 Part-8) using vibratory roller of 8 to 10 Tonne capacity to obtain 75-80% of maximum dry density complete all as specified and directed. Note: Care shall be taken not to disturb PVDs while filling and compacting the sand layer.

45333

-

-

... More
M&L for 50 mm thick crushed stone dust filling in pavings, laid in layers not exc. 15cm thick, spread, levelled and rammed including watering and rolling complete all as specified and as directed.

4534

-

-

... More
Supply and laying of 630mm outer dia. (PE-100, PN-16) HDPE pipe confirming to IS 4984-2016 and shall be jointed/laid in accordance with latest IS-7634 Part-2, slotted around circumference all as shown in drawing and specified for sub surface drain including necessary bend, connectors etc to maintain proper gradient to drain out water to the final disposal point complete all as specified and as directed. Note: Slots shall be of length 65mm and width 5mm with spacing 25mm on whole circumference of the pipe.

2136

-

-

... More
Supplying and installation of cassagrande's piezometers including all fittings & accessories as shown in drawing to monitor the consolidation of soil during ground improvement by PVD method during surcharge loading complete all as specified and as directed.

32

-

-

... More
Supplying and installation of settlement gauges including all fittings & accessories as shown in drawing to monitor the consolidation of soil during ground improvement by PVD method during surcharge loading complete all as specified and as directed.

32

-

-

... More
Supply and installation of temporary sump with rotational moulded polyethylene water storage tanks (cylindrical vertical) of 2000 litre capacity and fixed in position at the end for collection of sub drain & underground water during the surcharge period including excavation, dewatering and necessary pumping arrangement for disposal of water from the storage tank to the nearest storm drains and loose filling of sump with size of 20-40mm aggregate after completion of soil stabilization without any extra cost, complete all as specified and as directed.

8

-

-

... More
Preparation and surface treatment of formation by removing mud and slurry, watering to extent need to maintain the desired moisture content, trimming to the required line, grade and profile and rolling with smooth wheeled roller complete all as specified and as directed.

9067

-

-

... More
Supply and laying/wrapping of Non-woven Polypropylene Geotextile having minimum weight 285 gm per Sq.m. and minimum thickness 2.50mm (Confirming to clause 702, Table 700-5 of MORTH 5th Revision) complete all as specified and as directed.

103524

-

-

... More
Supply and installation of Prefabricated Verticle Drains (PVD) of size 100mm wide x 5mm thick (Minimum thickness) at a spacing of 1.2m in triangular pattern by using drain stitcher over the entire area as shown on drawing and complete all as specified and as directed. Notes: 1. PVDs shall be cut after installation in such a manner that PVD head length of 400mm can be embedded in a sand blanket of 500mm thickness as shown in drawing. 2. PVDs shall consist of corrugated inner core wrapped in non woven geotextile (Polypropylene) and shall have discharge capacity not less than 100x10-6 m3/s under hydraulic gradient of 1 at pressure of 250 kPa. 3. The rate quoted shall include the cost of labour, equipment, material, marking etc. required for installation of PVDs. 4. PVD installation shall be got done as per manufacturer’s instructions and through authorized/nominated applicator/installer of manufacturer of PVD. 5. PVD shall be procured from the following manufacturers: (a) M/s TECHFAB (b) M/s TENCATE (c) M/s NYLEX

661057

-

-

... More
M&L for laying and compacting 300mm (compacted thickness) Granular Sub Base (GSB) Grade V in two layers of 150mm each (grading and physical requirements as per Table 400-1 and 400-2 respectively of MORTH specification for road and bridge works) over compacted sub grade with natural sand, crushed gravel, crushed stone, crushed slag, or combination thereof as per grading required, all the materials mechanically mixed, spread and levelled on the sub grade by using motor grader of adequate capacity, and rolling with vibratory roller of capacity 80-100 kN static weight for achieving required compaction density of at least 98% of the maximum dry density including consolidating to required gradient and camber complete all as specified and as directed and finishing the surface tolerance as per table 900-1 of MORTH specifications for Road and Bridge works, 2013 complete all as specified and as directed. Notes: 1. Payment shall be made for solid quantity arrived after consolidation. 2. Compaction of granular sub base filling shall be carried out under optimum moisture conditions to achieve 98 % of modified proctor density. 3. Before execution of this item the approved material obtained from outside MD land shall be tested/checked for suitability to use. 4. The lead/royalty involved is to be ascertained by the contractor before quoting his tender and no extra payment/adjustment for increased in lead or rate of royalty due to whatsoever reason shall be admissible on his account. 5. The contractor shall use vibratory earth compactor in lieu of power roller to achieve 98% maximum dry density (MDD) at OMC without any extra cost and the method of compaction to be adopted as per recommendation of agency reporting max density at OMC 6. GSB shall be as per MORTH specification as detailed in particular specification.

6563.6

-

-

... More
M&L for laying and compacting 225mm thick (compacted thickness) of Wet Mixed Macadam (WMM), in three layers of 75mm thick each manufactured in WMM plant, each layer compacted separately (physical requirements and grading as per Table 400-12 and 400-13 respectively of MORTH specification for Road and Bridge works), material comprising of clean, crushed, graded aggregate and granular material premixed with water to as dense mass, spreading using sensor paver including spreading and compacting using double drum smooth wheeled vibratory roller with 80-100 kN static weight for achieving required compaction density of at least 98% of the maximum dry density and rolled consolidated to required gradient and camber complete as specified, including the soundness test catered out on the material delivered at site as per IS 2386 (Part-5) in case the water absorption value of coarse aggregates is grater than 2%, and finishing the surface tolerances as per Table 900-1 of MORTH specifications for Road and Bridge works complete all as specified and as directed. Notes: 1. The rate quoted shall be for the entire compacted thickness (each layer shall be rolled and compacted separately as described). 2. The Maximum Dry Density shall be determined using modified proctor density determination method as per IS code on prepared GSB surface. 3. Each layer of WMM shall not be more than 100mm / 150mm and shall not less than 75mm thick.

6563.6

-

-

... More
M&L for Dry Lean Concrete (DLC) of compacted thickness 100mm in single layer of aggregate gradation as per Table 1 of SP 49: 2014 having 7 day average compressive strength not less than 10 mPa with minimum cement content not less than 140 kg/Cu.m., DLC mixed in batching plant, transported to site and laid by electronic sensor paver including spreading and compacting using high amplitude tamping bars of paver (Initial compaction), further drum smooth wheeled vibratory rollers with 80-100 kN static weight to achieve minimum dry density not less than 98% of that achieved during the trial length construction including necessary finishing etc. complete all as specified and as directed. Notes: 1. No price adjustments shall be applicable if excess quantity of cement i.e. more than the minimum mentioned above is approved based on mix design in the execution of work under this item and quoted rates are deemed to be included for the same. 2. DLC shall be as per MORTH specification and as detailed in PS.

6563.6

-

-

... More
M&L for dry clean river sand passing through IS sieve 2.36mm and held in IS sieve 600 micron, spread and compacted to 10mm thickness complete all as specified and as directed.

656.76

-

-

... More
M&L for 400 micron HDPE sheet (Virgin Quality) water proof, wrinkle free polyethylene sheeting without puncture having minimum weight 390 gm/Sq.m. over tack coat/sand cushion as specified in design with overlap between adjacent strips as minimum 300mm and transverse joints at ends as minimum 300mm with maximum standard width available as approved by GE without joints, manufactured by multilayer technology using 100% virgin raw material, confirming to IS: 10889 complete all as specified and as directed. Notes: 1. Sand layer shall be measured and paid separately under BoQ item No.23. 2. Company logo, IS code, and batch number shall be marked on HDPE sheet at every 2 meters. 3. Rate is inclusive of overlaps at joints.

65631

-

-

... More
M&L for Pavement Quality Concrete (PQC) 400mm thick of minimum 28 days field flexural strength 45 Kg/Sq.cm. or 4.5 MPa, aggregate gradation as per Table 3 of IRC 15-2017, coarse aggregate of clean, hard, strong, dense, non-porous and durable pieces of crushed stone or gravel, fine aggregates of clean natural sand or crushed stone or combination of both, using minimum 360 Kg/Cu.m. of cement content with non-circular synthetic fibreof 12-18mm length, specific gravity 1.34 to 1.39, UV stable, alkali resistant, with equivalent dia., 15-40 micron, minimum melting temperature as 240°C and minimum tensile strength of 300 Mpa and at the rate as specified by the manufacturer, laid, spread and compacted with slip-form paver of minimum 9.0m width, including curing and tinning by texturing cum curing machine including required surface texturing all as specified in Clause 10.1.14 and Table 9 of IRC 15-2017 complete all as specified and as directed. Notes: 1. Construction joints/dummy joints and expansion joints shall be measured and paid separately under respective items. 2. Deduction shall be made in computing concrete quantity for expansion joints. 3. Contractor shall consider minimum 400 Kg of cement per cubic meter of concrete while quoting this item. Actual quantity of cement shall be used as per approved design mix. No price adjustment shall be applicable for excess quantity of cement content i.e. beyond 400 Kg as per approved design mix in execution of work. 4. Non circular synthetic fiber shall be mixed in the PQC @ 0.25% of cement all as per manufacturers instructions and as directed. 5. Supply only of non circular synthetic fibre shall be measured and paid separately. 6. Cost of steel formwork and testing as specified shall be deemed to be included in the rate quoted by the tenderer. 7. Maximum working temperature shall not exceed 30 degree centigrade of atmosphere. 8. Required surface texturing to be done as specified in Clause 10.1.14 and Table 9 of IRC: 15-2017.

26252.4

-

-

... More
Supply only non-circular, virgin, synthetic, monofilament polyester fibres of length 12mm to 18mm, specific gravity 1.34 to 1.39, UV stable, alkali resistant, equivalent diameter 15-40 micron, minimum melting temperature 250o C and minimum tensile strength 300 MPa complete all as specified and as directed. Notes:1. All properties/specifications to meet test parameters as per IS 16481:2016. 2. Design mix to be prepared after incorporating fibres.

26252.4

-

-

... More
M&L for forming 25mm wide expansion joint for 400mm thick PQC by cutting using high RPM diamond cutter of appropriate size, straight and smooth edges, early entry saw and subsequent full depth cutting, cleaning the joint thoroughly with application of compressed air and making dry, vacuum cleaned and free of dirt, oil, vegetation and other debris and filling the joint with pre-molded 25mm thick compressible polyethylene closed cell type filler board as specified and thereafter applying two coats of primer with thin brush by forward and backward movement at an interval of 30 minutes before placing the backup rod and pouring the sealant, placing the closed cell, medium density, crossed linked polyethylene foam backup rod of 30mm dia., over filler board and filled with polyurethane based sealant (fuel resistant) complying with BS-5212, BS 4254 and EN-141875-2003 with minimum movement accommodation factor (MAF) of +/- 30% having minimum 10 years performance guarantee, applying masked tape on the edges of joints to prevent accidental spill age of sealant and removing the masking tape after filling of sealant and removing the masking tape after filling of sealant as per the method specified and directed by the manufacturer complete all as specified and as directed. Notes: 1. The polyethylene rod shall be of desired diameter having minimum density of 22 Kg/Cu.m. and compression strength of 0.40 Kg/Sq.m. of white colour. 2. Primer to be used before filling sealant. 3. The joint filler shall be pre-moulded, compressive filler board with high performance closed-cell material available in board form (HD 100) and shall comply with the requirements of ASTM-D3575/IS standards (latest revision).

424

-

-

... More
M&L for cutting of construction joints 25mm deep and 10mm wide by early entry saw cut using diamond bit cutter of appropriate size, straight and smooth edges, cleaning the joint thoroughly with application of compressed air, making dry, vacuum cleaned and free of dirt, oil, vegetation and other debris, applying two coats of primer with thin brush by forward and backward movement at an interval of 30 minutes before placing the backup rod and pouring the sealant, placing of closed cell, medium density, crossed linked polyethylene foam backup rod of 12mm dia., applying the bond breaker tape on top of back up rod for complete width of the joint and filled with polyurethane based sealant (fuel resistant) complying with BS-5212, BS-4254 and EN-141875-2003 with minimum movement accommodation factor (MAF) of +/- 30% having minimum 10 year performance guarantee, applying masked tape on the edges of joints to prevent accidental spill age of sealant and removing the masking tape after filling of sealant as per the method specified and directed by the manufacturer complete all as specified and as directed. Notes: 1. The polyethylene rod shall be of desired diameter having minimum density of 22 Kg/Cu.m. and compression strength of 0.40 Kg/Sq.m., of white colour. 2. Primer to be used before filling sealant. 3. The Joint filler shall be pre-moulded, compressive filler board with high performance closed-cell material available in board form (HD 100) and shall comply with the requirements of ASTM-D3575/IS Standards (latest revision).

831

-

-

... More
M&L for forming contraction (Dummy) joints of 8mm wide and depth 1/3 to 1/4 the thickness of slab (250mm thick PQC) using high RPM diamond cutter with and initial saw cut of 3mm soon after concrete has set, widening the first saw cut to 8mm width and 24mm deep from the top using diamond bit cutter of appropriate size, straight and smooth edges, cleaning the joint thoroughly with application of compressed air and making dry, vacuum cleaned and free of dirt, oil, vegetation and other debris, applying two coats of primer with thin brush by forward and backward movement at an interval of 30 minutes before placing the backup rod and pouring the sealant, placing of closed cell, medium density, crossed linked polyethylene foam backup rod of 10mm dia., applying the bond breaker tape on top of back up rod for complete width of the joint and filled with polyurethane based sealant (fuel resistant) complying with BS-5212, BS-4254 and EN-141875-2003 with minimum movement accommodation factor (MAF) of +/- 30% having minimum 10 year performance guarantee, applying masked tape on the edges of joints to prevent accidental spill age of sealant and removing the masking tape after filling of sealant as per the method specified and directed by the manufacturer complete all as specified and as directed. Notes: 1. The polyethylene rod shall be of desired diameter having minimum density of 22 Kg/Cu.m. and compression strength of 0.40 Kg/Sq.m., of white colour. 2. Primer to be used before filling sealant. 3. The Joint filler shall be pre-moulded, compressive filler board with high performance closed-cell material available in board form (HD 100) and shall comply with the requirements of ASTM-D3575/IS Standards (latest revision). 4. Cutting of joints shall be completed within 24 hours.

1479.4

-

-

... More
M&L for painting lines, dashes, arrows, letters etc. on roads surface with hot applied retro reflective thermoplastic paint confirming to MORTH (Clause 803.40) all as specified with 8% glass beads using special applicator machine with heating arrangement up to 160oC, including cleaning & drying the road surfaces to ensure dust, oil, grease & moisture free surface before applying paint complete all as specified and as directed.

513

-

-

... More
EXTERNAL WATER SUPPLY

-

-

-

... More
M&L for cutting the existing 200 mm dia DI/MS pipe for additions and alterations including necessarily done in position without taking down and inserting Tee 200 x200x 150 mm for tapping including all fittings and fixtures complete all as specified and as directed.

1

-

-

... More
M&L for 150 mm dia ductile iron pipe spigot and socket type centrifugally cast (spun) all as per IS:8329-2000, class K9 with flexible rubber gasket push on type joint having cement mortar lining with portland slag cement as per IS 455 : 1989 bituminous coating as per Annex 'C' of IS 8329, including provision of specials, such as tee's, elbows, bends, reducers, taper pieces complete all as specified and directed.

2020

-

-

... More
S&F Centrifugal pump set, 40m head and 20 LPS discharge, capacity 30 HP with suitable induction motor 1450 RPM, 3 phse AC supply complete with base, DOL starter and all accessories including all necessory electrical and water supply connections complete. all as specified and as directed.

2

-

-

... More
M&L for earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of Plate not less than 1.50 m below normal ground level connected to 32x6mm thick GI strip [earth lead] and GI pipe 50 mm, medium grade for earthing lead protection to the extent of maximum 7.5m, earth plate electrode surrounded by 150 mm thick packed layers of charcoal and common salt filled in alternate layers, connected to the Plate by means of GI Bolts & Nuts complete all as per electrical plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, charcoal, common salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40x40 x6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. complete all as specified. Note: GI earth strip upto 7.5 metres shall be deemed to be included in the quoted lumpsum and beyond 7.5 metre shall be measured and paid separately under relavent item.

204

-

-

... More
Supply, Install, test and commissioning of LT panel outdoor type floor mounted made of 3.15 mm thick, MS sheet front operated cubical type 3 phase, 4 wire AC 415 Volts complete with 50mm x 50mm x 6mm angle iron frame work , ventilated side louvers, suitable aluminium links/conductor from bus bar, painting with one coat of red oxide primer and two coats of synthetic enamel paint complete with and including the following complete all as specified and directed.

1

-

-

... More
a) 200 A Copper bus bar (b) 0-500 V Voltmeter square type with selector switch - 1 No (c) 0-500A Ammeter selector switch with CT's - 01 No (d) MCCB 4 pole, 125 Amps, 36 KA breaking capacity - 1 No e) LED Indicating Lamps for each phase with colour code Red Yellow Blue for R, Y and B Phases for each breakers : 01 No [Set of 03] f) MCCB 3 pole, 63 Amps, 35 KA breaking capacity - 02 No g) MCB 3 pole, 32 Amps, 16 KA breaking capacity - 01 No

-

-

-

... More
M&L for masonry valve chamber of size 1000 X 1000 X 1000 mm [interanl dimensions] comprising of 50mm thick PCC for valve including excavation and earth work in any type of soil and 200 mm thick PCC 1:4:8 type D2 foundation, brick work in CM (1:6) plastring internal surface 15 mm tick in CM (1:4) PCC (1:3:6) type B1 couping 50 x50x6 mm angle iron 3 mm thick MS plate cover complete with locking arrangement painting steel and iron surface with two coat of synthetic enamel paint over a coat of zinc chrome primer complete all as specified and as directed.

2

-

-

... More
EXTERNAL ELECTRIFICATION

-

-

-

... More
Supply and lay 3½ core 35 Sq.mm. cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of the following sizes complete all as specified and as directed.

70

-

-

... More
All as per SI item No 90 above but for 2 core 6 Sq.mm.

200

-

-

... More
M&L for cable route indicator made of CI disc 100mm dia., 6mm thick with inscription of HT cable 11000 Volts, fixed to MS angle of size 40x40x6mm, 750mm long with bolts & nuts, duly grouted in PCC 1:3:6 type C1 (Using 20mm grade stone aggregate) complete including necessary excavation and earth work complete all as specified and as directed.

5

-

-

... More
Supply and lay 90x75mm bore double walled corrugated (DWC) pipe, heavy duty, for cable protection as a guard pipe including required accessories etc., of the following sizes complete all as specified and as directed.

56

-

-

... More
All as per SI item No 93 above but for 40x32mm bore

160

-

-

... More
Supply, Installation, testing & commissioning of Floor mounted, Outdoor Type Factory manufactured, Extendable HT 33kV 25KA VCB panels switchboard consisting of 800A, VCB 33 kV - 2 Nos as outgoing (suitable to existing VCB). VCB panel Outdoor type totally enclosed, free standing floor mounting type, compartment based with truck mounted vacuum circuit breaker spring operated electrically and manually charged operating mechanism suitable for horizontal isolation, horizontal draw out type VCBs with Aluminum bus bars, Self supported Insulated Busbar with full voltage rated should be used. Complete VCB panel confirming to IEC 62271-200 standards and IP 4X class of protection comprising necessary bus-bars extension and connections and following protective and control devices as specified below. Vacuum Interrupters of the circuit breakers shall be completely encapsulated in epoxy housing. The manufacturer of circuit breaker shall also be the manufacturer of the Vacuum Interrupter, Relay. The switchgear and control gear panels shall be complete all as specified and as directed. Make: ABB /Kanyaka parameshwari Engineering Limited [KPEL]/ Schneider / Siemens.

1

-

-

... More
OUTGOING - 2 Nos ( Each consisting of ) 33 kV Indoor Switchgear Panel consisting of Breaker-800A, 25 KA draw out type having following accessories for Transformer Outgoing a. 230VAC Spring Charge Motor b.110VDC Closing Coil c.110VDC Shunt Trip Coil d. Current Transformer Indoor Single Phase Resin Cast Ratio: 200-100/5-5A Core-1: 15VA Class 0.5, Core -2 15VA 5P10 e. Potential Transformer Resin cast Ratio : 33kV/√3/110V/√3 50VA, CLASS: 0.5 -3 Nos g. Digital Voltmeter with VSS h. Multifunction Load Manager Class 0.5 with RS485 & Ethernet communication i. Master Trip Relay j. Auxiliary Relays for Transformer Protection k. Numerical Protection IEC 61850 Draw out Relay with Graphical display- 1 No with Three Phase O/C & E/F (50, 51, 50N, 51N, 50G, 51G), Three Phase Directional O/C & E/F (67/67N), Negative Phase Sequence O/C (46), Inrush Detection (68), Circuit Breaker Failure Protection (50BF), Broken Conductor (46BC), Three Phase O/V, U/V & NDR (27, 59, 59N) , Thermal Overload (49), Negative Sequence Overvoltage (47), Reverse Power (32), Over Frequency (81O), Under Frequency (81U), CT Supervision (60 CTS), VT Fuse Failure (60 VTS) , Auto Recloser (79), Relay shall have 8 DI and 8 DO. Makes: ABB/CG/Schneider/Siemens.

-

-

-

... More
l. Suitable space heater arrangement to prevent moisture condensation m. Regulated 230VAC supply shall be arranged from an external source for misc. requirements like space heater, LED illumination etc. shall be provided at a single location inside the panel by the contractor n. Construction of plinth for 33kV VCB: Excavation of pit of size 3.5MX2.5MX0.6M, filling with sand for 150mm depth, laying bed concrete with PCC (1:4:8) Using 40mm HBG metal for 150mm, construction of plinth as per drawing (2 supports) with RR Masonry of size 0.837 cum and plastering all around the outer side with CM (1:5) 12 mm Thick and White washing 3 coats including cost and transport of all material and labour charges for all operation incidental charges etc.., completes all as specified and as direted.

-

-

-

... More
Supply, Installation, testing & commissioning of Floor mounted, Indoor Type Factory manufactured, Cable In, Cable Out HT 33kV 25KA VCB panel switchboard consisting of 800A, VCB 33 kV - 1Nos. VCB panel indoor type totally enclosed, free standing floor mounting type, compartment based with truck mounted vacuum circuit breaker spring operated electrically and manually charged operating mechanism suitable for horizontal isolation, horizontal draw out type VCBs with Aluminum bus bars, Self supported Insulated Busbar with full voltage rated should be used. Complete VCB panel confirming to IEC 62271-200 standards and IP 4X class of protection comprising necessary bus-bars extension and connections and following protective and control devices as specified below. Vacuum Interrupters of the circuit breakers shall be completely encapsulated in epoxy housing. The manufacturer of circuit breaker shall also be the manufacturer of the Vacuum Interrupter, Relay. The switchgear and control gear panels shall be complete all as specified and as directed. Make: ABB /CG / Schneider / Siemens.

2

-

-

... More
33kV Indoor Switchgear Panel consisting of Breaker-800A, 25kA draw out type having following accessories a. 230V AC Spring Charge Motor b.110V DC Closing Coil c.110V DC Shunt Trip Coil d. Current Transformer Indoor Single Phase Resin Cast Ratio: 100-50/5-5A Core-1: 15VA Class 0.5, Core -2 15VA 5P10, Core -3: Class PS - 3 Nos e. Potential Transformer Resin cast Ratio : 33kV/√3/110V/√3 50VA, CLASS: 0.5 -3 Nos f. 12 window Annunciator g. Digital Ammeter with ASS h. Digital Voltmeter with VSS i. Multifunction Load Manager Class 0.5 with RS485 & Ethernet communication j. Master Trip Relay k. Power pack 100W with battery backup l. Numerical Protection IEC 61850 Draw out Relay with Graphical display- 1 No with Three Phase O/C & E/F (50, 51, 50N, 51N, 50G, 51G), Three Phase Directional O/C & E/F (67/67N), Negative Phase Sequence O/C (46), Inrush Detection (68), Circuit Breaker Failure Protection (50BF), Broken Conductor (46BC), Three Phase O/V, U/V & NDR (27, 59, 59N) ,Thermal Overload (49),Negative Sequence Overvoltage (47) ,Reverse Power (32),Over Frequency (81O), Under Frequency (81U), CT Supervision (60 CTS) ,VT Fuse Failure (60 VTS),Auto Recloser (79). Relay shall have 8 DI and 8 DO. Makes: ABB/CG/Schneider/Siemens.

-

-

-

... More
m. Numerical Relay Differential protection (87T) - 1nos n. Control panel consisting of Relays for WTI Alram & Trip, OTI Alram & Trip, Bucholtz Alram & Trip, Over load Alram & Trip.

-

-

-

... More
Supply installation testing and commissioning of 3500 kVA 33/11 kV, delta/Star, vector group, DYN11 ONAN, outdoor type copper wound transformer with On load tap Changers having AVS relay & RTCC for automatic sensing of incoming voltage, automatic operation of OLTC & facilty for remote manual operation of OLTC, suitable for incoming voltage variation of +5% to - 15% in equal steps of 1.25% to give a constant secondary voltage, the transformer shall be provided with fitting accessories, protection, first filling of oil & confirming to IS 2026 (P-1 to P-5) etc. i/c Buchholz relay, oil/winding temperature alarm/trip protection complete as per specifications as required, the transformer oil-Natural Oil cooled should have dielectric strength of 60 kV. No Load Losses maximum of 3.5KW and Load Loss 27KW, the transformer shall be provided with arrangement to terminate upto 3 core 240 sq mm XLPE cable on primary and secondary side including supplying and laying of copper conductor multicore control cable from transformer to breaker for safety tripping, suitably mounted on MS channel i/c supply and grouting of suitable MS channel with all accessories as required as directed, (temperature rise for top oil shall not exceed 50 Deg C above ambient and winding temperature rise shall not exceed 55 deg C over ambient. The transformer shall be provided with 3 Nos Surge Arrestor on HT side, Manufacturer should have Short circuit test report for similar or Higher rating transformer (Any rating), If SC test report is not available, then bidder has to conduct the same without any extra cost to the purchaser. Make: ABB /Kanyaka parameshwari Engineering Limited [KPEL]/ Schneider / Siemens.

2

-

-

... More
i) Applicable Standard IS:2026 ii) Service Outdoor iii) Fittings and Accessories iv) Rating,3.5 kVA v) Rated no load voltage a) HV,33 kV b) LV, 11kV vi) Frequency 50 Hertz vii) List Of Accessories a Oil Temperature Indicator 1 No. b Winding Temperature Indicator 1 No. c Pressure Relief Device 1 No. d Magnetic Oil Level Gauge 1 No. e Buchholz Relay 1 No. f Marshalling Box (IP-65) 1 No. g Bi-directional Roller 4 No. h Jacking Pads 4 No. i Conservator 1 No. j Silica Gel Breather 1 No. k AVR (Microcontroller Type) 1 No. l RTCC Panel (IP-42) 1 No. m Note: Only those figures subject to tolerances as per IS:2026 are guaranteed Upward and downward revision in weights and dimensions shall not form the basis for upward or downward revision in prices later. Prepared By: Checked By: HV, LV line and N CT's are not considered in the offer because of no technical details and if required later shall be provided on additional cost.

-

-

-

... More
viii) Overloading Of Transformer IS 2026 - 7 ix) Radiator Sheet Thickness / Material 1 mm / CRCA 29 Insulating Oil Natural ESTER OIL x) Tank Sheet Thickness (Side/Top/Bottom) 5 / 5 / 5 mm xi) Paint Type EPOXY xii) Short Circuit Withstand Capability As per IS 2026 xiii) % Efficiency at 75degC/0.8 P.F. a) At 100% load 98.64 b) At 75% load 98.91 c) At 50% load 99.13 xiv) % Efficiency at 75degC/Unity P.F. a) At 100% load 98.91 b) At 75% load 99.12 c) At 50% load 99.30 xv) % Regulation at full load a) Unity P.F. 1.25 b) At 0.8 P.F. 5.18 xvi) Performance figures @ 3.5 MVA Base a) No load loss, kW (MAX) 3.5 b) Load loss, kW (MAX) 35 c) Auxiliary loss, kW NA d) Impedance,% (IS Tol) 7.15 xvii) Number of phases 3 xviii) Vector Group reference Dyn11

-

-

-

... More
xix) Winding Insulation - LV Uniform - Class A xx) Winding Insulation - HV Uniform - Class A xxi) Winding BIL - HV 170 kVp/ 70 kVrms Winding BIL - HV-N NA Winding BIL - LV 75kVp / 28 kVrms Winding BIL - LV-N 75kVp / 28 kVrms xxii) Terminal arrangement, HV/LV Cable Box / cable box xxiii) Taps on winding a) Off ckt / On load On load tap changer b) Tapping range +5% to -15 % c) No. of steps 16 Steps @ 1.25% d) Tap Switch CTR/OLG xxiv) Temp. rise oil/wdg. 50/55

-

-

-

... More
Supply, Installation, Testing & Commissioning of Battery Bank consisting of 110V, 55 Nos of 2 Volt 100AH VRLA Battery along with terminal connectors, wooden rack and all other accessories as per Technical specification complete all as specified and directed. Make: Amararaja/Exide

1

-

-

... More
Supply, Installation, Testing and Commissioning of 110V/100AH 25A FCBC Thyristor based with in-built DCDB and RS485 communication , three Phase 4 Wire, Full Wave, Full Controlled, Thyrister based Charger with VRLA Battery in complete as specified and directed. Make: Amararaja/Exide

1

-

-

... More
Supply & Lay 33kV(E) grade cable suitable for earthed system having compacted circular stranded aluminum conductor shielded with semi- conducting compound water tree retardant (TR) extruded layer XLPE insulated dry and nitrogen cooled, dry cured core shielded with semi-conducting compound extruded layer followed by metallic copper foil, screened inner sheath of extruded PVC TYPE ST 2, galvanized single flat steel strip armoured and PVC TYPE ST 2 sheathed overall conforming to IS: 7098/Part-II/1985, amended upto date with ISI marked of size 3 core 120 Sqmm complete in trenches/ ducts/ on pole etc complete all as directed. Makes: Finolex/Universal/RPG/Polycab/KEI

2800

-

-

... More
S&F cable jointing kit for 33 kV grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE, armoured ,Aluminium conductor cable of size 120 sqmm complete all as specified and directed.

4

-

-

... More
S&F cable jointing kit for 33 kV grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Aluminium conductor cable of size 120 Sqmm complete all as specified and directed.

4

-

-

... More
S&F cable jointing kit for 33 kV grade cable for outdoor straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Aluminium conductor cable of size 120 Sqmm complete all as specified and directed.

4

-

-

... More
Supply, lay and testing XLPE insulated and PVC sheathed, FRLS, GI Strip / Wire armoured heavy duty cable, ISI marked with Multistranded Copper Conductor 1100 Volt grade of size 4 Core, 2.5 Sq.mm cross section suitable for earthed system, laying in trenches / duct / fixed to poles / drawn through pipes / sleeving through pipe in duct, including suitable size Double compression copper stainless steel cable gland, crimping type cable lugs, sockets etc., complete all as specified and as directed.

80

-

-

... More
Supplying, laying and testing XLPE insulated and PVC sheathed, FRLS, GI Strip / Wire armoured heavy duty cable, ISI marked with Multistranded Copper Conductor 1100 Volt grade of size 5 Core, 4 Sq.mm cross section suitable for earthed system, laying in trenches / duct / fixed to poles / drawn through pipes / sleeving through pipe in duct, including suitable size Double compression copper stainless steel cable gland, crimping type cable lugs, sockets etc. including taking down old Cables of any description complete all as specified and as directed.

150

-

-

... More
Supplying, laying and testing XLPE insulated and PVC sheathed, FRLS, GI Strip / Wire armoured heavy duty cable, ISI marked with Multistranded Copper Conductor 1100 Volt grade of size 14 Core, 2.5 Sq.mm cross section suitable for earthed system, laying in trenches / duct / fixed to poles / drawn through pipes / sleeving through pipe in duct, including suitable size Double compression copper stainless steel cable gland, crimping type cable lugs, sockets etc. including taking down old Cables of any description complete all as specified and as directed.

150

-

-

... More
Supply of 33kV Grade Insulating Mat as per IS 15652, of size 2000 mm x 1000 mm complete all as specified and as directed.

4

-

-

... More
Material and labour for earthing of copper earth plate electrode 600mm x 600mm x 3.15 mm thick buried directly in ground (earth pit not less than 2.25 mtr depth below normal ground level) with top edge of earth not less than 1.5mtr below normal ground level connected to and including earth lead wire 4.0 mm by means of steel bolts, nuts, check nuts and washers, test point made of copper strip 20 x 3 mm, 10cm long PCC 1:2:4, type B1 in pit with precast RCC 1:2:4 type B1 in cover reinforced with XPM not less than 4 Kg per Sqm with 15mm bore GI light grade protection pipe, 20mm bore GI medium grade watering pipe with funnel including charcoal, dust, salt, all as shown in electric plate No 3 of SSR Part-I (2209) Specifications, complete with necessary earth work in any type of soil, removal to a distance not exceeding 50 mtr, including testing on completion, complete all as specified and directed by Engr-in-Charge Note:The cost of earth work, PCC pit, CI cover,funnel, watering pipe, wire mesh, charcoal, dust, common salt, 20mm bore medium grade watering pipe & 15 mm bore light grade GI pipe as protection to earth lead wire shall be deemed included in the unit rate for earthing complete all as specified and as directed.

14

-

-

... More
S&F 50 mm X 6 mm earth continuity copper strip or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc. as required complete all as specified and as directed.

60

-

-

... More
Supply, Install, testing & commissioning of Factory Made 11 kV, 630 Amps, 21kA for 3 Seconds, AFLR, SF6 Insulated, Motorised, Outdoor extensible type, 4 Way RMU Consisting of 1 No VCB as Incoming and 3 Nos. of VCBs as Outgoing and Metering Module With FRTU & SCADA Compatible With complete all specified and as directed and shall comprise of the following: Make: ABB / Schneider / Siemens / BHEL The make of Vacuum Interrupter & VCB of same make as the Ring Main unit. Important Note: The RMU should be manufactured at OEM factory only. No other mode of manufacturing is accepted.

2

-

-

... More
[A] RMU shall be 11 kV, 630 Amps, 21 kA for 3 Seconds, Internal Arc 21kA/1Sec, AFLR, SF6 Insulated, Motorized, Outdoor, 4 Way RMU, Left side Extensible, Right Side Metering Unit, SACADA compatable Overload and eart fault protection Relay (Ashidha / CSPDR) with Air Insulated Bus Connected Metering unit (Type +VVVVVV+M), Type tested in line with latest IEC Standards, suitable for operations at a height up to 1000 Meters above sea level and at 40ºC Ambient Temperature, Switchgear and Busbar shall all be contained in a SF6 Tank shall be sealed for life robotically welded non magnetic and non ferrite Stainless Steel Enclosure [2.5MM thickness SS304], nominal operating gas pressure 1.3 BAR @20 Deg C, RMU Tank shall provide Full Insulation and Switchgear shall be insensitive to the environment with Degree of Protection of IP67 filled with SF6 gas as insulation with leakage rate less than 0.1% per year tested as per IEC 62271-200. Painting thickness shall be atleast 60microns , Breaker shall be M2 Class- 10,000 operations at rated normal current and 10 operations at rated Short circuit breaking current. Manual welding or hermetic sealing of tank shall be not be accepted., The unit shall have front cable entry (Suitbale for termination of 1R x 3C x 95.120/150 Sqmm Cable )for ease of installation and shall have site replaceable bushings for ease of troubleshooting during breakdown. RMU should be complete with all accessories such as Terminal boots, VPIS, cable supports, all front cable terminations, mechanical indications for VCB and Load break switch ON/OFF, Manometer as per with IEC standards 62271-200, 60056, 60129, 60265, 60298, 60420, 60529 and 60694.

-

-

-

... More
Altitude of installation up to 1000m as per IEC 60120. Bushings bolted type top mounted outside the tank for connection of external bus bar. Switchgear Operating Mechanism shall have an IP2X Protection and Cable Chamber shall have IP3X Protection, Outer Enclosure shall be IP 54 type tested, Painting (FRONT COVER RMU: RAL7035 & (FOR MIMIC RAL7043)) & ENCLOSURE: RAL7035 & (TOP COVER & BASE STAND IN RAL 7043)). The unit shall be internal arc proof 21kA for 1 se with AFLR clasification. tested and totally safe for human beings. The gas release & personnel safety from internal arc shall not depend on plinth design. The release of gas to be from the top of the unit, so that, even if the person is operating the unit, opening the cover, & there are personnels near the sides of the RMU/plinth, top release will ensure their safety. The hot gas release, in case of an internal arc, in no case should be from any side or bottom of the unit, as the same is unsafe for the operating personnel/pedestrian or general public. Bidder shall provide type test report to prove compliance to the Internal Arc fault IAC-AFLR as per IEC 62271-200. Internal arc testing shall be done with enclosure door in open condition, with switching devices in operation mode as per specified standard. The Vacuum Bottle shall be of same make as RMU Manufacturer .

-

-

-

... More
[B] Vacuum Circuit Breaker [VCB] Each shall be comprising of the following: [i] 11 kV, 630 Amps, 21 kA/ 3s, 3 Pole Manual/ Motorised VCB with 3 pole manual disconnector and 3 pole manual earth switch, manual/ motorized Spring Assisted Mechanism and Series Trip Coil – 1 No. [ii] Self Powered Relay with O/C, S/C, E/F Protection – 1 No [iii] CT Ratio 200-100/1A, Class - 1.0, 2.5VA for Metering and CT Ratio 200-100/1A, Class 5P10, 2.5 VA for Protection – 1 Set each [iv] Live Cable Indicator with indications at the Front and Three Inlets to check the Synchronization of Phases – 1 No [v] Cable Termination Bushing suitable for up to 1 Run, 3 Core, 185 Sq.mm, XLPE Cable – 1 Set [vi] Cable Termination Cover Boots [Push on type] – 1 Set [C] Vacuum Circuit Breaker [VCB] Each shall be comprising of the following: [i] 11 kV, 630 Amps, 21 kA/ 3s, 3 Pole Manual/ Motorised VCB with 3 pole manual disconnector and 3 pole manual earth switch, manual/ motorized Spring Assisted Mechanism and Series Trip Coil – 1 No. [ii] Self Powered Relay with O/C, S/C, E/F Protection – 1 No [iii] CT Ratio 200-100/1A, Class - 1.0, 2.5VA for Metering and CT Ratio 200-100/1A, Class 5P10, 2.5 VA for Protection – 1 Set each [iv] Live Cable Indicator with indications at the Front and Three Inlets to check the Synchronization of Phases – 1 No [v] Cable Termination Bushing suitable for up to 1 Run, 3 Core, 185 Sq.mm, XLPE Cable – 1 Set [vi] Cable Termination Cover Boots [Push on type] – 1 Set

-

-

-

... More
[D] Air Insulated Bus Connected Metering Unit comprising the following: – 1 Set [i] Air Insulated Enclosure with necessary Bus Connection – 1 No [ii] PT 11kV / RT 3 / 110V / RT3, 25 VA, Class-1.0 – 1 Set [iii] Voltmeter with Selector Switch – 1 No [iv] R / Y / B Indicating Lamps – 1 Set [v] 11 kV / 230V AC, Class 1, 500VA Control Transformer – 1 No [vi] Battery and Battery Charger, 12 Ah, [I/P-230V AC, O/P - 24V DC] – 1 No Note: [a] An operator situated in front, lateral and rear [A-FLR 21 kA – 1 Sec, Downwards Exhaust, for Tank as well as Cable Compartment] of the RMU Switch board during an internal fault shall not be exposed to the effects of Arcing. Internal Arc Type Test Report for IAC AFLR 21 kA for 1 Sec for both Tank & Cable Box shall be for minimum as per OEM standards. [b] All operations shall of the RMU shall be as per OEM standards. [c] Copy of the Type Test reports as per latest IEC shall be submitted along with drawings for approvals. (D) FRTU MAKE Shall be of (VEGO)

-

-

-

... More
Supply ,fix ,connecting ,testing and commissioning of OEM Manufactured APFC Panel (automatic and manual operation) with 7% Aluminium reactor of capacity 100kVAR (Output) @ 440 V AC interconnection with LT Panel/ Transformer (outdoor/indoor) with appropriate size of electric power cable 1.1kV . The stage rating shall be [50+25+15] + (5x2) kVAR. The APFC Panel shall be fully type tested at an independnt Laboratory and shall comply with IEC 61439-1&2 and IEC 61921, IS-16636-2017.The degree of protection of enclosure system of the APFC Panel shall be min IP 54 (Outdoor) in accordance with IEC 60529. The capacitor bank shall be internet of things (IoT) enabled and communicable / integrable with BMS . The APFC Panel shall be Outdoor type confirming to IS 13341:1992 & IS13440:1993 floor mounted design fabricated out of 14 SWG CRCA Sheet treated through chemical with 8 tank process method of degreasing,derusting and phosphating powder coating(60-80 microns),painted in SIEMENS GREY (RAL 7032) shade powder coating paint, weather ,dust and vermin proof suitable for humidity upto 95% and having four nos iron legs made of 50x50x6mm thick, 60cm long angle iron below frame with front door and side/back opening having locking arrangement prewired with

1

-

-

... More
copper conductor PVC insulated wire size 2.5 sqmm/ extension strips and connected with suitable size thimbles & lugs. The legs duly embedded in ground (45cm) in PCC 1:3:6 type C1 (using 20mm aggregate), Cable entry from bottom. Transparent Acrylic sheet/Bakelite sheet will be provided for shrouding, Average daily temperature : +35 degree celcius max, Ambient temperature :-5 degree celcius to 40 degree celcius, Maximum altitude 2000m. Approved Make of Panel:-ABB/SCHNEIDER/SIEMENS/L&T/CMKL make only. The OEM 's specified cannot authorize any other partners / sub vendors to manufacture APFC Panels on their behalf . The APFC Panel manufacturered by OEM's only will be accepted & factory acceptance test (FAT) will be carried out at OEM's plant only.The APFC Panel shall be comprising of the followings:-

-

-

-

... More
(A) Insulated bus bar with colour coded heat shrinkable sleeves with SMC/DMC insulators pan assembly made from Aluminium and rated of 1200 Amps capacity .The short circuit withstand capacity shall be 50KA/1sec(Icw) for the main bus bar and the rated impulse withstand voltage shall be 6kV.The Panel shall have phase indication lamp for R/Y/B voltages 230 volts,ON/OFF indication lamps for capacitor steps,PUSH BUTTON start/stop for capacitors steps,digital [power factor meter,auto manual selector switch,on delay timer,CT 100/5Amp(03 nos),CL-1.0,10VA resin cast / nylon case for metering complete all as specified and as directed. (B)The incomer of the APFC Panel shall be a 200 Amp MCCB 3P 50KA TMD type with O/L & S/C protection , Ics = 100% Icu, MCCB shall have standard extended rotary handle spreaders phase barrier MCCB shall be of certified design confirming to IEC 60947-1,2&3.Approved makes: ABB/SCHNEIDER/SIEMENS/L&T (C) PF Regulator / APFC Relay : Advanced Range PF Regulator / microprocessor based APFC relay (VARPLUS LOGIC OF SCHNEIDER) having 5 steps with a LCD Display ,Voltage Range:90V-550V,50Hz/60Hz,CT Input:1A/5A with a built in RS 485 communication port .The PF Regulator shall be of certified design confirming to IEC 61326. Approved makes: ABB/SCHNEIDER/SIEMENS/L&T

-

-

-

... More
(D)Accessories D(i) Capacitor Units: The capacitor unit shall be metalized polypropylene film with Zn/Al alloy for 480Volts. The capacitors shall be encapsulated in an aluminium can.The capacitor unit shall have a rated voltage of 480Volts and shall have a maximum over current capacity of 2.5In. The capacitor unit shall have a built in 3 phase over pressure protection and shall habve discharge resistors (50V in 1min) factory fitted and shall be tamper proof .Capacitance Tolerance -5% +10%.Maximum permissible over voltage 1.1 x Un,8h every 24Hour.The capacitor unit shall be of certified design confirming to IS-13340-1993,13341-1992&IEC-60831-1&2.Approved makes: ABB/SCHNEIDER/SIEMENS/L&T D(ii). Short circuit and Overload Protection : Each stage of the APFC Panel shall have a suitably rated MCCB for short circuit and overload protection .The over current setting shall be adjustable & breaking capacity Ics = 36KA . The MCCB shall be of certified design fort TP 36KA T/M based release with O/L & S/C Protection--01no confirming to IEC 60947-1,2&3 . The Detuned Reactor (Al wound) should be equipped with Thermal switch inside the winding which should cut off the respective contactor in case of Over temperature .Tolerance of reactors shall not exceed +/-3% of rated value.Approved makes: ABB/SCHNEIDER/SIEMENS/L&T D(iii) Stage Contactor : The capacitor duty contactors shall be rated for 230 volts AC and shall be 3 pole type and shall be employed for switching on and switching off operations in capacitor banks.The contactor shall be AC-3 duty type .The contactor shall be of certified design conforming to IEC 60947-1&4-1. Approved makes: ABB/SCHNEIDER/SIEMENS/L&T

-

-

-

... More
D(iv) Reactor: Harmonics blocks reactors(01 no) Al wound with 7% filtering factor shall be connected in series with each capacitor stage and shall be of iron cored type . The Reactor should be equipped with thermal switch inside the winding which should cutoff the respective contactor in case of Over temperature .Tolerance of reactors shalln not exceed +/-3% of rated value.The reactors shall be of certified design confirming to IEC 60076-6.Approved makes: ABB/SCHNEIDER/SIEMENS/L&T

-

-

-

... More
All as per Serial Item No.127 here-in-before but 200 kVAR [3x50]+ [2x12.5]+ [1x25]

2

-

-

... More
All as per Serial Item No. 127 here-in-before but 300 kVAR [1x100]+ [3x50]+ [2x25]

1

-

-

... More
Supply, fix, testing and commisioning of LT FPB made out of CRCA sheet 3 mm thick outdoor Pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, and the nuts/ bolts etc., used are to be made of rust proof material including as per IS: 8623 tinned copper bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V 1500 A capacity complete with powder coating, necessary internal electric connection as required with and including the following complete all as specified and as directed.

1

-

-

... More
Incoming: LT switch gear 440 Volts 3 phase, 4 wire 50 cycles, cubicle or truck type complete with air circuit breaker, with microprocessor release IPR -E eletrical draw type 1000 Amps, 100 KA , overload protection, No-Volt release with necessary CTs, meter and cable boxes of rating upto - 01 NO Outgoing: MCCB, AC 3 Phase, 415 V, 50Hz, 4 pole, 800Amps capactiy 100KA with adjustable type thermal and magnetic setting relays - 02 Nos MCCB AC 3 Phase 415 V, 50Hz 4 pole 200 A capactiy 36 kA with adjustable type thermal and magnetic setting relays - 01 Nos d) Intelligent Panel meter to measure voltage, current, frequency, power factor, etc with all connected CTs c) LED indicating lamps with colour Red, Yellow, Blue - 01 Set

-

-

-

... More
LT FPB made out of CRCA sheet 3 mm thick outdoor Pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, and the nuts/ bolts etc used are to be made of rust proof material incl as per IS: 8623 tinned copper bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V 1200 A capacity complete with powder coating, necessary internal electric connection as required with and including the following complete all as specified and as directed.

1

-

-

... More
Incoming: MCCB AC 3 Phase 415 V, 50Hz 4 pole 800A capactiy 100KA with adjustable type thermal and magnetic setting relays - 01 Nos Outgoing: MCCB AC 3 Phase 415 V, 50Hz 4 pole 250A capactiy 36 kA with adjustable type thermal and magnetic setting relays - 02 Nos MCCB AC 3 Phase 415 V, 50Hz 4 pole 100 A capactiy 50 kA with adjustable type thermal and magnetic setting relays - 01 Nos MCCB AC 3 Phase 415 V, 50Hz 4 pole 63A capactiy 25 kA with adjustable type thermal and magnetic setting relays - 01 Nos MCCB AC 3 Phase 415 V, 50Hz 4 pole 125A capactiy 50 kA with adjustable type thermal and magnetic setting relays - 01 Nos MCCB AC 3 Phase 415 V, 50Hz 4 pole 32 A capactiy 25 kA with adjustable type thermal and magnetic setting relays - 01 Nos MCB TPN 20 Amp 10 kA, 3 Pole, thermal magnetic release, with adjustable type overload protection, short circuit protection, with necessary CTs, meters and cable boxes. -03 Nos d) Intelligent Panel meter to measure voltage, current, frequency, power factor, etc with all connected CTs c) LED indicating lamps with colour Red, Yellow, Blue - 01 Set

-

-

-

... More
LT FPB made out of CRCA sheet 3.15 mm thick outdoor Pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, and the nuts/ bolts etc used are to be made of rust proof material incl as per IS: 8623 tinned copper bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V 3000 A capacity complete with powder coating, necessary internal electric connection as required with and including the following complete all as specified and as directed.

1

-

-

... More
Incoming: LT switch gear 440 Volts 3 phase, 4 wire 50 cycles, cubicle or truck type complete with air circuit breaker, with microprocessor release IPR -E eletrical draw type 2000 Amp, 200 KA , overload protection, no-volt release with necessary CTs,meter and cable boxes of rating upto - 01 NO Outgoing: MCCB AC 3 Phase 415 V, 50Hz 4 pole 1600A capactiy 100 kA with adjustable type thermal and magnetic setting relays - 02 Nos MCCB AC 3 Phase 415 V, 50Hz 4 pole 400 A capactiy 36 kA with adjustable type thermal and magnetic setting relays - 01 Nos d) Intelligent Panel meter to measure voltage, current, frequency, power factor, etc with all connected CTs c) LED indicating lamps with colour Red, Yellow, Blue - 01 Set

-

-

-

... More
LT FPB made out of CRCA sheet 3.15 mm thick outdoor Pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, and the nuts/ bolts etc used are to be made of rust proof material incl as per IS: 8623 tinned copper bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V 2400 A capacity complete with powder coating, necessary internal electric connection as required with and including the following complete all as specified and as directed.

1

-

-

... More
Incoming: MCCB AC 3 Phase 415 V, 50Hz 4 pole 1600A capactiy 100 kA with adjustable type thermal and magnetic setting relays - 01 Nos Outgoing: MCCB AC 3 Phase 415 V, 50Hz 4 pole 630A capactiy 36 kA with adjustable type thermal and magnetic setting relays - 02 Nos MCCB AC 3 Phase 415 V, 50Hz 4 pole 160 A capactiy 36 kA with adjustable type thermal and magnetic setting relays - 02 Nos MCCB AC 3 Phase 415 V, 50Hz 4 pole 400 A capactiy 50 kA with adjustable type thermal and magnetic setting relays - 02 Nos MCCB AC 3 Phase 415 V, 50Hz 4 pole 320 A capactiy 50 kA with adjustable type thermal and magnetic setting relays - 01 Nos MCB TPN 20 Amp 10 kA, 3 Pole, thermal magnetic release, with adjustable type overload protection, short circuit protection, with necessary CTs, meters and cable boxes. -03 Nos MCB SPN 20 Amp 10 kA, 3 Pole, thermal magnetic release, with adjustable type overload protection, short circuit protection, with necessary CTs, meters and cable boxes. -01 Nos d) Intelligent Panel meter to measure voltage, current, frequency, power factor, etc with all connected CTs c) LED indicating lamps with colour Red, Yellow, Blue - 01 Set

-

-

-

... More
LT FPB made out of CRCA sheet 3.15 mm thick outdoor Pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, and the nuts/ bolts etc used are to be made of rust proof material incl as per IS: 8623 tinned copper bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V 800 A capacity complete with powder coating, necessary internal electric connection as required with and including the following complete all as specified and as directed.

1

-

-

... More
Incoming: MCCB AC 3 Phase 415 V, 50Hz 4 pole 500A capactiy 36 kA with adjustable type thermal and magnetic setting relays - 01 Nos Outgoing: MCCB AC 3 Phase 415 V, 50Hz 4 pole 125A capactiy 20 kA with adjustable type thermal and magnetic setting relays - 03 Nos MCCB AC 3 Phase 415 V, 50Hz 4 pole 100 A capactiy 36 kA with adjustable type thermal and magnetic setting relays - 01 Nos MCCB AC 3 Phase 415 V, 50Hz 4 pole 63 A capactiy 25 kA with adjustable type thermal and magnetic setting relays - 01 Nos MCCB AC 3 Phase 415 V, 50Hz 4 pole 32 A capactiy 25 kA with adjustable type thermal and magnetic setting relays - 01 Nos d) Intelligent Panel meter to measure voltage, current, frequency, power factor, etc with all connected CTs c) LED indicating lamps with colour Red, Yellow, Blue - 01 Set

-

-

-

... More
LT FPB made out of CRCA sheet 3.15 mm thick outdoor Pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, and the nuts/ bolts etc used are to be made of rust proof material incl as per IS: 8623 tinned copper bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V 600 A capacity complete with powder coating, necessary internal electric connection as required with and including the following complete all as specified and as directed.

1

-

-

... More
Incoming: MCCB AC 3 Phase 415 V, 50Hz 4 pole 400A capactiy 36 kA with adjustable type thermal and magnetic setting relays - 01 Nos Outgoing: MCCB AC 3 Phase 415 V, 50Hz 4 pole 125A capactiy 20 kA with adjustable type thermal and magnetic setting relays - 02 Nos MCCB AC 3 Phase 415 V, 50Hz 4 pole 100 A capactiy 36 kA with adjustable type thermal and magnetic setting relays - 01 Nos MCCB AC 3 Phase 415 V, 50Hz 4 pole 40 A capactiy 25 kA with adjustable type thermal and magnetic setting relays - 02 Nos MCCB AC 3 Phase 415 V, 50Hz 4 pole 32 A capactiy 25 kA with adjustable type thermal and magnetic setting relays - 01 Nos MCCB AC 3 Phase 415 V, 50Hz 4 pole 63 A capactiy 25 kA with adjustable type thermal and magnetic setting relays - 02 Nos d) Intelligent Panel meter to measure voltage, current, frequency, power factor, etc with all connected CTs c) LED indicating lamps with colour Red, Yellow, Blue - 01 Set

-

-

-

... More
LT FPB made out of CRCA sheet 3.15 mm thick outdoor Pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, and the nuts/ bolts etc used are to be made of rust proof material incl as per IS: 8623 tinned copper bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V 3000 A capacity complete with powder coating, necessary internal electric connection as required with and including the following complete all as specified and as directed.

1

-

-

... More
Incoming: LT switch gear 440 Volts 3 phase, 4 wire 50 cycles, cubicle or truck type complete with air circuit breaker, with microprocessor release IPR -E eletrical draw type 2000 Amps, 100 KA , overload protection, No-Volt release with necessary CTs, meter and cable boxes of rating upto - 01 NO Outgoing: MCCB AC 3 Phase 415 V, 50Hz 4 pole 1600A capactiy 1000 kA with adjustable type thermal and magnetic setting relays - 02 Nos MCCB AC 3 Phase 415 V, 50Hz 4 pole 400 A capactiy 36 kA with adjustable type thermal and magnetic setting relays - 01 Nos d) Intelligent Panel meter to measure voltage, current, frequency, power factor, etc with all connected CTs c) LED indicating lamps with colour Red, Yellow, Blue - 01 Set

-

-

-

... More
LT FPB made out of CRCA sheet 3.15 mm thick outdoor Pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, and the nuts/ bolts etc used are to be made of rust proof material incl as per IS: 8623 tinned copper bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V 2400 A capacity complete with powder coating, necessary internal electric connection as required with and including the following complete all as specified and as directed.

1

-

-

... More
Incoming: MCCB AC 3 Phase 415 V, 50Hz 4 pole 1600A capactiy 100 kA with adjustable type thermal and magnetic setting relays - 01 Nos Outgoing: MCCB AC 3 Phase 415 V, 50Hz 4 pole 630 capactiy 36 kA with adjustable type thermal and magnetic setting relays - 02 Nos MCCB AC 3 Phase 415 V, 50Hz 4 pole 160 A capactiy 36 kA with adjustable type thermal and magnetic setting relays - 02 Nos MCCB AC 3 Phase 415 V, 50Hz 4 pole 400 A capactiy 50 kA with adjustable type thermal and magnetic setting relays - 02 Nos MCCB AC 3 Phase 415 V, 50Hz 4 pole 320 A capactiy 50 kA with adjustable type thermal and magnetic setting relays - 01 Nos MCB TPN 20 Amp 10 kA, 3 Pole, thermal magnetic release, with adjustable type overload protection, short circuit protection, with necessary CTs, meters and cable boxes. -03 Nos MCB SPN 20 Amp 10 kA, 3 Pole, thermal magnetic release, with adjustable type overload protection, short circuit protection, with necessary CTs, meters and cable boxes. -01 Nos d) Intelligent Panel meter to measure voltage, current, frequency, power factor, etc with all connected CTs c) LED indicating lamps with colour Red, Yellow, Blue - 01 Set

-

-

-

... More
LT FPB made out of CRCA sheet 3.15 mm thick outdoor Pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, and the nuts/ bolts etc used are to be made of rust proof material incl as per IS: 8623 tinned copper bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V 500 A capacity complete with powder coating, necessary internal electric connection as required with and including the following complete all as specified and as directed.

1

-

-

... More
Incoming: MCCB AC 3 Phase 415 V, 50Hz 4 pole 320A capactiy 100 kA with adjustable type thermal and magnetic setting relays - 01 Nos Outgoing: MCCB AC 3 Phase 415 V, 50Hz 4 pole 100A capactiy 36 kA with adjustable type thermal and magnetic setting relays - 02 Nos MCCB AC 3 Phase 415 V, 50Hz 4 pole 80 A capactiy 36 kA with adjustable type thermal and magnetic setting relays - 02 Nos MCCB AC 3 Phase 415 V, 50Hz 4 pole 32 A capactiy 50 kA with adjustable type thermal and magnetic setting relays - 02 Nos MCCB AC 3 Phase 415 V, 50Hz 4 pole 63 A capactiy 50 kA with adjustable type thermal and magnetic setting relays - 01 Nos d) Intelligent Panel meter to measure voltage, current, frequency, power factor, etc with all connected CTs c) LED indicating lamps with colour Red, Yellow, Blue - 01 Set

-

-

-

... More
LT FPB made out of CRCA sheet 3.15 mm thick outdoor Pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, and the nuts/ bolts etc used are to be made of rust proof material incl as per IS: 8623 tinned copper bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V 600 A capacity complete with powder coating, necessary internal electric connection as required with and including the following complete all as specified and as directed.

1

-

-

... More
Incoming: MCCB AC 3 Phase 415 V, 50Hz 4 pole 400A capactiy 100 kA with adjustable type thermal and magnetic setting relays - 01 Nos Outgoing: MCCB AC 3 Phase 415 V, 50Hz 4 pole 32A capactiy 50 kA with adjustable type thermal and magnetic setting relays - 01 Nos MCCB AC 3 Phase 415 V, 50Hz 4 pole 250 A capactiy 50 kA with adjustable type thermal and magnetic setting relays - 02 Nos MCCB AC 3 Phase 415 V, 50Hz 4 pole 63 A capactiy 50 kA with adjustable type thermal and magnetic setting relays - 01 Nos d) Intelligent Panel meter to measure voltage, current, frequency, power factor, etc with all connected CTs c) LED indicating lamps with colour Red, Yellow, Blue - 01 Set

-

-

-

... More
LT FPB made out of CRCA sheet 3.15 mm thick outdoor Pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, and the nuts/ bolts etc used are to be made of rust proof material incl as per IS: 8623 tinned copper bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V 3800 A capacity complete with powder coating, necessary internal electric connection as required with and including the following complete all as specified and as directed.

1

-

-

... More
Incoming: LT switch gear 440 Volts 3 phase, 4 wire 50 cycles, cubicle or truck type complete with air circuit breaker, with microprocessor release IPR -E eletrical draw type 2500 Amps, 200 KA , overload protection, No-Volt release with necessary CTs, meter and cable boxes of rating upto - 01 NO Outgoing: MCCB AC 3 Phase 415 V, 50Hz 4 pole 2000A capactiy 100 kA with adjustable type thermal and magnetic setting relays - 02 Nos MCCB AC 3 Phase 415 V, 50Hz 4 pole 500 A capactiy 36 kA with adjustable type thermal and magnetic setting relays - 01 Nos d) Intelligent Panel meter to measure voltage, current, frequency, power factor, etc with all connected CTs c) LED indicating lamps with colour Red, Yellow, Blue - 01 Set

-

-

-

... More
LT FPB made out of CRCA sheet 3.15 mm thick outdoor Pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, and the nuts/ bolts etc used are to be made of rust proof material incl as per IS: 8623 tinned copper bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V 3800 A capacity complete with powder coating, necessary internal electric connection as required with and including the following complete all as specified and as directed.

1

-

-

... More
Incoming: MCCB AC 3 Phase 415 V, 50Hz 4 pole 2000A capactiy 100 kA with adjustable type thermal and magnetic setting relays - 01 Nos Outgoing: MCCB AC 3 Phase 415 V, 50Hz 4 pole 63 capactiy 50 kA with adjustable type thermal and magnetic setting relays - 01 No MCCB AC 3 Phase 415 V, 50Hz 4 pole 800 A capactiy 36 kA with adjustable type thermal and magnetic setting relays - 01 Nos MCCB AC 3 Phase 415 V, 50Hz 4 pole 500 A capactiy 36 kA with adjustable type thermal and magnetic setting relays - 01 Nos MCCB AC 3 Phase 415 V, 50Hz 4 pole 1000 A capactiy 25 kA with adjustable type thermal and magnetic setting relays - 02 Nos d) Intelligent Panel meter to measure voltage, current, frequency, power factor, etc with all connected CTs c) LED indicating lamps with colour Red, Yellow, Blue - 01 Set

-

-

-

... More
LT FPB made out of CRCA sheet 3.15 mm thick outdoor Pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, and the nuts/ bolts etc used are to be made of rust proof material incl as per IS: 8623 tinned copper bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V 1200 A capacity complete with powder coating, necessary internal electric connection as required with and including the following complete all as specified and as directed.

1

-

-

... More
Incoming: MCCB AC 3 Phase 415 V, 50Hz 4 pole 800A capactiy 36 kA with adjustable type thermal and magnetic setting relays - 01 Nos Outgoing: MCCB AC 3 Phase 415 V, 50Hz 4 pole 400 A capactiy 20 kA with adjustable type thermal and magnetic setting relays - 03 Nos MCCB AC 3 Phase 415 V, 50Hz 4 pole 40 A capactiy 36 kA with adjustable type thermal and magnetic setting relays - 01 Nos d) Intelligent Panel meter to measure voltage, current, frequency, power factor, etc with all connected CTs c) LED indicating lamps with colour Red, Yellow, Blue - 01 Set

-

-

-

... More
LT FPB made out of CRCA sheet 3.15 mm thick outdoor Pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, and the nuts/ bolts etc used are to be made of rust proof material incl as per IS: 8623 tinned copper bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V 800 A capacity complete with powder coating, necessary internal electric connection as required with and including the following complete all as specified and as directed.

1

-

-

... More
Incoming: MCCB AC 3 Phase 415 V, 50Hz 4 pole 500A capactiy 36 kA with adjustable type thermal and magnetic setting relays - 01 Nos Outgoing: MCCB AC 3 Phase 415 V, 50Hz 4 pole 250 A capactiy 20 kA with adjustable type thermal and magnetic setting relays - 03 Nos d) Intelligent Panel meter to measure voltage, current, frequency, power factor, etc with all connected CTs c) LED indicating lamps with colour Red, Yellow, Blue - 01 Set

-

-

-

... More
LT FPB made out of CRCA sheet 3.15 mm thick outdoor Pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, and the nuts/ bolts etc used are to be made of rust proof material incl as per IS: 8623 tinned copper bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V 1500 A capacity complete with powder coating, necessary internal electric connection as required with and including the following complete all as specified and as directed.

1

-

-

... More
Incoming: MCCB AC 3 Phase 415 V, 50Hz 4 pole 1000A capactiy 36 kA with adjustable type thermal and magnetic setting relays - 01 Nos Outgoing: MCCB AC 3 Phase 415 V, 50Hz 4 pole 250A capactiy 20 kA with adjustable type thermal and magnetic setting relays - 03 Nos MCCB AC 3 Phase 415 V, 50Hz 4 pole 40 A capactiy 20 kA with adjustable type thermal and magnetic setting relays - 01 No MCCB AC 3 Phase 415 V, 50Hz 4 pole 125 A capactiy 20 kA with adjustable type thermal and magnetic setting relays - 04 Nos d) Intelligent Panel meter to measure voltage, current, frequency, power factor, etc with all connected CTs c) LED indicating lamps with colour Red, Yellow, Blue - 01 Set

-

-

-

... More
S&F Loop in loop out box of FRP made with IP 65 protection of thermoplasic circuit breaker boxes with metric knock outs for cable entry and exit, Combi climate Cable Glands of IP 66/ IP 67 for cable entry and Grommets IP 65 for conduit for cable exit with MCB 6 Amps, 10 kA, 'C' Curve Overload and Short Circuit protection, terminals as bus terminals for cable with necessary fixing arrangemets and with cable glands, etc., complete all as specified and as directed.

60

-

-

... More
S&F time switches 415 Volts, three Phase, 20 Amps rating with contactor fitted inside steel enclosure complete all as specified and as directed.

4

-

-

... More
Supply and Lay 180x152 mm bore Double walled corrugated pipe (DWC) heavy duty for cable protection as a guard pipe including required accessories etc., complete all as specified and diected.

1220

-

-

... More
Supply and Lay 160x135 mm bore Double walled corrugated pipe (DWC) heavy duty for cable protection as a guard pipe including required accessories etc., complete all as specified and diected.

640

-

-

... More
Supply and Lay 120x103 mm bore Double walled corrugated pipe (DWC) heavy duty for cable protection as a guard pipe including required accessories etc., complete all as specified and diected.

300

-

-

... More
Supply and Lay 110x95mm bore Double walled corrugated pipe (DWC) heavy duty for cable protection as a guard pipe including required accessories etc., complete all as specified and diected.

360

-

-

... More
Supply and Lay 90x75mm bore Double walled corrugated pipe (DWC) heavy duty for cable protection as a guard pipe including required accessories etc., complete all as specified and diected.

370

-

-

... More
Supply and Lay 77x63mm bore Double walled corrugated pipe (DWC) heavy duty for cable protection as a guard pipe including required accessories etc., complete all as specified and diected.

740

-

-

... More
M&L for Cable Route Indicator made of CI disc of size 100mm dia, 6mm thick with inscription of HT Cable / 11000 Volts fixed to MS angle of size 40 X 40 X 6mm, 750mm long with bolts & nuts, duly embedded in PCC, 1:3:6, Type C1 complete including necessary excavation and earth work all as specified and as directed.

95

-

-

... More
M&L for RCC Cable Route Indicator semi-circular shape on top of size 600x450x100 mm casted in PCC 1:3:6 with TMT bars 100 mm dia and foudation base casted in RCC 1:2:4 embedded in earth upto 550 mm duly engraved the following letters " HT UG CABLE 33 kV " with two coats of anti fungal waether proof paint etc., complete all as specified and as directed.

60

-

-

... More
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and as directed.

80

-

-

... More
M&L for GI pipe light grade 150 mm dia for cable protection on road crossings /plinth protection with fixed to the pole wall etc. suitable fittings for cable protection . complete all as specified and as directed.

10

-

-

... More
M&L for Cutting the tarmac / hard standings and excavating in trenches across the road for laying cable including making good the excavated portion by means of PCC 1:3:6, type C1 matching with the surroundings complete all as specified and as directed.

2

-

-

... More
AREA DRAINAGE:

-

-

-

... More
M&L for pre-cast RCC M-30 as in factory made cover slabs, set in cement mortar 1:4 including use and waste of form work complete all as specified and as directed.

71

-

-

... More
RETAINING WALL:

-

-

-

... More
Boring for bored cast-in-situ piles 500mm dia. in any type of soil/clay/ soft rock except hard rock/fractured rock using DMC (Direct Mud Circulation) method of boring and getting out and disposal of spoil out side MD land complete all as specified and as directed.

4347

-

-

... More
Boring for 500mm dia. bored cast in situ piles in hard rock using DMC method (Direct Mud Circulation) complete and getting out and disposal of spoil out side MD land all as specified and as directed.

805

-

-

... More
Cutting, chipping of laitance concrete in piles above cut of level up to a maximum of 1m from cut of level and disposal to distance of exc. 1.5 km but not exc. 5 km and depositing where directed complete all as specified and as directed.

64

-

-

... More
M&L for MS pipe liner fabricated out of 6mm thick plain MS plate confirming to Fe-410 S by welding the joints, strengthening wherever required, providing stiffners, lifting hooks including all T&P required, shifting the same from position to positions required, driving in true vertical alignment in position to the required level for piles complete all as specified and as directed. Note: MS Pipe liner shall be casted as mentioned in drawing. How ever for payment purpose, the depth of pile liner shall be measured up to cut off level only irrespective of the depth provide for retaining concrete/ bentonite slurry. The unit rate/lumsum price quoted shall be deemed to include for the above aspect.

142866

-

-

... More
S&F 25mm thick pre-formed compressible polyethylene closed cell type filler board for expansion joints complete all as specified and as directed.

26

-

-

... More
Carrying out initial load test (Vertical load) on 500mm dia. Cast in situ pile as per IS 2911 Part-IV, complete all as specified and as directed.

2

-

-

... More
Carrying out initial load test (Lateral load) on 500mm dia. Cast in situ pile as per IS 2911 Part-IV, complete all as specified and as directed.

2

-

-

... More
Carrying out routine load test (Vertical load) on 500mm dia. Cast in situ pile as per IS 2911 Part-IV, complete all as specified and as directed.

2

-

-

... More
Carrying out routine load test (Lateral load) on 500mm dia. Cat in situ pile as per IS 2911 Part-IV, complete all as specified and as directed.

2

-

-

... More
Carrying out low strain integrity test on cast in situ piles 500mm dia. including analysing the result as per ASTM D 5882 complete all as specified and as directed. Note fot Item Nos.55 to 59: Test results shall be approved by the CWE. The GE shall intimate CWE before commencing the load test and the test shall be carried out in presence of the authorised representative detailed by the CWE.

322

-

-

... More
FIRE FIGHTING SYSTEM/ FIRE ALARM SYSTEM

-

-

-

... More
S&F Booster pump Panel 40 Amps, 4 pole MCB ,DOL starter with AMP & VOLT meter, RYB indicator Lamp, Mild steel fabricated Powder Coated with suitable cable for connection of required Flow switch to reduce Flow as required complete all as specified and directed.

1

-

-

... More
Supply, install, testing and commissioning of compartmentalised common PLC control panel for Electrical motor driven pumps and Diesel engine driven pumps with and including complete all as specified and directed.

2

-

-

... More
Incoming: MCCB AC 3 Phase 415 V, 50Hz 4 pole 400A capactiy 50 kA with adjustable type thermal and magnetic setting relays - 02 Nos Copper bus bar 600 Amps : 2 Sets [All bus bars with colour coded heat shrinkable PVC sleeves] LED indicating lamps with colour Red, Yellow, Blue with individual HRC control fuses - 02 Sets Voltmeter with seelctor switch 0-800 Amps - 02 Nos OUTGOING Feeder for main pumps - 2 Nos. MCCB AC 3 Phase 415 V, 50Hz 4 pole 200A capactiy 50 kA with adjustable type thermal and magnetic setting relays - 02 Nos Star delta starter with over load relay, single phase preventor and indicating lamps with ON / OFF push buttons. Feeder for Jockey pump - 1 No. MCCB AC 3 Phase 415 V, 50Hz 3 pole 320A capactiy 50 kA with adjustable type thermal and magnetic setting relays - 02 Nos DOL starter with over load relay, single phase preventor and indicating lamps with ON / OFF push buttons. Automanual selector switch: 2 Nos

-

-

-

... More
Feeder for Booster pumps - 1 Nos. MCCB AC 3 Phase 415 V, 50Hz 3 pole 320A capactiy 50 kA with adjustable type thermal and magnetic setting relays - 02 Nos DOL starter with over load relay, single phase preventor and indicating lamps with ON / OFF push buttons. Automanual selector switch: 1 Nos Feeder for Booster pumps - 1 Nos. MCCB AC 3 Phase 415 V, 50Hz 3 pole 320A capactiy 50 kA with adjustable type thermal and magnetic setting relays - 02 Nos DOL starter with over load relay, single phase preventor and indicating lamps with ON / OFF push buttons. Automanual selector switch: 1 Nos DIESEL ENGINE MAIN PUMP 1 No. MCB DP 20 Amp 10 kA, 2 Pole, thermal magnetic release, with adjustable type overload protection, short circuit protection, with necessary CTs, meters and cable boxes. -04 Nos b) Battery charger with transformer with rectifier resistance DC ammeter, DC voltmeter, Trickle / booster / off selector switch - 2 Nos.

-

-

-

... More
c) 1 set of indicating lamps for the following 1. phase indication 2. battery charger on 3. over load relay 4. DC supply on 5. control switch on 6. Engine fails to start 7. Pump on 8. Low oil pressure 9. High water temperature 10. Auto manual selector switch d) 1 sets of push button stations for the following : 1. Engine Start 2. Engine Stop 3. Engine - hooter ACK 4. Engine - fault reset g) Hooter for audio alarm (Industrial type) - 1 No. All the components shall be housed in a common cubical made of 16 swg. M.S. sheet with required stiffners ( if required). The panel shall be powder coated of approved colour both inside & out side. The panel shall have both bottom & top cable entry provisions and panel shall be mounted on Pedastal of 300 mm height.

-

-

-

... More
S&F 32 mm bore lever operated brass/ bronze ball valve of full flow with SS Balls having minimum working pressure of 16 Kg / Cm2 approved quality (screwed end) complete all as specified and as directed.

13

-

-

... More
S&Fing, 25mm dia. gunmetal Air release valve PN 1.6 with all fittings and forged ball valve on header as required complete all as specified and as directed.

4

-

-

... More
M&L for masonry valve chamber of size 1200 X 1200 X 1000 mm [interanl dimensions] comprising of 50mm thick PCC for valve including excavation and earth work in any type of soil and 200 mm thick PCC 1:4:8 type D2 foundation, brick work in CM (1:6) plastring internal surface 15 mm tick in CM (1:4) PCC (1:3:6) type B1 couping 50 x50x6 mm angle iron 3 mm thick MS plate cover complete with locking arrangement painting steel and iron surface with two coat of synthetic enamel paint over a coat of zinc chrome primer complete all as specified and as directed.

13

-

-

... More
S&F electrical short circuit isolation Modules to protect the system against wire to wire short circuits on loops, to be installed at the rate of every 5 Nos monitor modules complete as per manufacturer specifications and in an accessible location as per site, excluding wiring to Annunciation Panel, with UL/EN approval complete all as specified and as directed.

56

-

-

... More
Supply & fix Microprocessor operated based UL/EN listed (Latest version) Inteligence Addressble Beam Detector with 4 manual & 2 acclimate senstive setting Trasmitter receiver built into same unit six user selectetable sensitivity levels 16" to 328' protection range Digital display built in Automatic main control compensate for signal detection from dust built up address switch to programme the detector complete as required complete all as specified and as directed.

35

-

-

... More
Supply & fix Microprocessor operated based UL/EN listed (Latest version) Wall mounted hooter-cum-strobe with minimum 90 db out put at distance of 1 mtr and with required power supply converter (230V AC to 12/24 VDC ) complete with termination etc., as required complete all as specified and as directed.

72

-

-

... More
S&F 25 mm bore, MS ERW pipe, heavy duty surface/ recess mounted and including bend/ elbows and necessary welding at site for making necessary tappings including painting with two coats synthetic enamel paint over a coat of primer complete all as specified and as directed.

5021

-

-

... More
S&F 20 mm bore, MS ERW pipe, heavy duty surface/ recess mounted and including bend/ elbows and necessary welding at site for making necessary tappings including painting with two coats synthetic enamel paint over a coat of primer complete all as specified and as directed.

2496

-

-

... More
Supply & fix FRLS PVC insulated copper conductor single core of size 2 × 1.5 sq mm armoured almunium foel slealed cable in the exiting surface/recess steel /PVC conduit as required complete all as specified and as directed.

7317

-

-

... More
S&F ISI marked portable type fire extinguishers CO2 type 4.5 kg capacity as per IS- 15683 complete all as specified and as directed.

73

-

-

... More
S&F ISI marked portable type fire extinguishers 22.5 kg capacity CO2 type cylindrical shape fire extinguisher (Trolley mounted) as per IS- 15683 complete all as specified and as directed.

30

-

-

... More
S&F ISI marked portable type fire extinguishers 6 Kg capacity ABC Dry Powder type as per IS- 15683 complete all as specified and as directed.

154

-

-

... More
S&F ISI marked portable type fire extinguishers 9 kg Mechanical foam as per IS- 15683 complete all as specified and as directed.

76

-

-

... More
S&F Mechanical Foam type (AFFF media) 50 Liters Capacity cylindrical shape fire extinguisher with gas cartridge, hose, trolley and all required accessories, complete as per IS-1338- trolley mounted type for portable use complete all as specified and as directed.

108

-

-

... More
S&F 3 Nos. G.I. sand buckets painted "Red Color" complete with G.I. stand duly painted "Red Colour" of suitable size to hang 3 Buckets at a time as per required specifications and as directed.

190

-

-

... More
S&F internal fire hose cabinet fabricated from 14 gauge SS-304, 2MM Thick sheet with single or double door, glazed front door and locking arrangement, vinyl tape 50% front side, “Fire Hose” with stove enameled paint, written on front, including necessary supports of approximate size 2100x 900x 715 mm deep to house two lengths of canvas hose with couplings, branch pipe, fire hose reel, nozzle, fireman axe, single outlet landing valve and first-aid hose reel, complete in all respects complete all as specified and as directed.

40

-

-

... More
LIGHTENING PROTECTION

-

-

-

... More
Supply, fix, testing and commissioning of Aviation lights, complete including PCC & 20mm dia pipe of length 1.5 mtr, complete with flasher as required complete all as specified and as directed. CAT No. BGAV 302 LED of BAJAJ or its equivalent in Philips / Havells / Surya Roshni Ltd / Wipro / GE

6

-

-

... More
Supply & fix wiring with 2 x 2.5 Sqmm for circuit wiring along with earth wire with 1 x 1.5 sq mm PVC insulated stranded copper conductor, single core cable in 25 mm dia PVC conduit from lift machine room DB to aviation light as required complete all as specified and as directed.

120

-

-

... More
S&F single pointed air terminal aluminium rod 12mm dia. 300mm long with aluminium box plate of size of 125x125x10mm fixed over porcelain insulator and fixed on roof top complete including 40mm dia. medium grade MS pipe 300mm long and including necessary fasteners fixed for lighting protection with necessary connections to earthing etc. complete all as specified and as directed.

103

-

-

... More
S&F horizontal roof conductor and down conductor of size 25x3.15mm aluminium strip fixed to walls/columns/projections/roof including porcelain blocks/DMC insulator spaced at 1m interval complete all as specified and as directed.

2620

-

-

... More
S&F test point terminal block made out of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos. 8mm dia. 25mm long hexagonal head screws etc. complete all as specified and as directed.

19

-

-

... More
Supply, fix, test and commissioning of aviation lights to 20 mm dia GI pipe medium grade 1.5 m length (including 300x300x300 mm PCC 1:2:4 foundation) complete all as specified and as directed. Make: Bajaj Cat. No.BGAV 302 LED or equivalent in Philips, CG

1

-

-

... More
M&L for earth continuity conductor or main earthing lead made of galvanised iron strip 32x6mm size, fixed to wall on batten or recess or chases or burried in ground or fixed to poles or any other indicated situation including drawing through GI pipe for earthing etc. complete all as specified and as directed.

52

-

-

... More
COOLING APPLIANCES

-

-

-

... More
S&F Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of +/- 2.5% and of capacity 0.5 kVA complete all as specified and directed.

42

-

-

... More
DG SET

-

-

-

... More
Supply, install testing & commissioning of Silent engine generating set with accoustic enclosure as per CPCB norms 415 volts, 300 kVA, 3 phase, 0.8 power factor, 50 Hz, 1500 RPM self excited self regulated brushless AC generator including accoustic enclosure suitable for ambient condition and conforming to condition under IS 4722, BS 5514/ 2613 /5000 with and including the following:- (i) The capacity of Generator set shall be net after all due de-rating factors as per relevant ISI design (ii) Rate quoted shall be deemed to be inclusive of cable and terminations form Generator to the AMF Panel, with necessary holes to wall including making good to disturbed surfaces so as to match with the existing finishes all as specified and directed. (iii) The quoted rate shall be deemed to be inclusive of first fill of oil and final successful acceptance test

1

-

-

... More
(A) Alternator: Standard design alternator rated at 500 kVA net output at site after considering de-rating as per site conditions at 0.8 (Lag) power factor AC, 3 Phase, 4 wire, 415 Volts, 50 Hz, 1500 RPM, self excited self regulated screen protected drip proof IP 23 enclosure brushless design with winding in pole faces, insulating class 'H' and voltage regulation of +/-1% at rated voltage from no load to full load. The alternator shall be conforming to BS 2613/5000 and shall be imposition to generate supply with frequency regulation with in +/-1% tolerance. The alternator will be suitable for tropical climate and shall generally conform to BS-2613/5000/IS-4722. (i) Insulation class-'H‘ (ii) Temperature rise Class-'H‘ (iii) Excitation: Self Excited (iv) Regulation Performance: The voltage is kept constant with +/-1%, manual voltage adjustment within +/-5% (v) Frequency regulation +/-1%

-

-

-

... More
(B) Diesel Engine: Adequate capacity of Diesel engine as approved by the Accepting Officer based on manufacturers technical details water cooled to drive independently above alternator and after considering de-rating as per site conditions after generating and reducing power consumed by accessories directly coupled through flexible coupling multi cylinder multi stroke direct injection, cold starting 1500 RPM, as per relevant ISI/BS-5514 with an overload capacity of 10% for one hour in 12 hours continuous running complete with standard accessories all as specified and required for safe handling and operation salient features of accessories shall be as under: (i) Fly wheel with housing (ii) Cooling System: Moulded radiator with fan & belts (iii) Cooling Water Pump: Centrifugal type belt driven (iv) Exhaust System: Exhaust System complete with exhaust piping of 150mm dia. with MS pipe light grade up to & outside and 1 meter away from the enclosure, covered with asbestos rope and aluminium foil of 28 SWG complete with in the enclosure for safe exhaust without transforming vibration to the wall of the enclosure. Exhaust gas turbo charger type. Exhaust manifold Silencer: Residual type Bellows (v) Fuel System: Fuel injection system with fuel injectors, fuel injection solenoid switch controlled by electronic governor for 1% speed/ frequency regulation, Fuel filters, Fuel hoses. (vi) Lub oil System: Lubricating oil filter, Lubricating oil pump (vii) Air Intake System: Air intake Manifold, Air cleaner dry type (viii) Governor: Electronic Governor

-

-

-

... More
(ix) Starting System: Electric Self starter with maintenance free battery including battery charging alternator (x) Batteries: Batteries of maintenance free of capacity as recommended by the manufacturer complete with copper conductor multi stranded leads of suitable length from self starter to the battery terminals complete with initial charge and initial fill of electrolyte all as specified and starter gear ring start and stop push button, Ignition key/switch. Handling and Operation: Salient features of accessories shall be as under: Radiator with blower fan Corrosion inhibitor coolant Paper element filters for fuel, lub oil and by pass Electronic governor controlled direct fuel injection system Fly wheel housing and fly wheel (xi) Generator Monitoring Panel: Comprising of all standard items as mentioned under this schedule or as per standard practice ignition key switch and start/stop arrangement, indications for engine parameters, hour run meter, RPM meter, engine oil pressure indicator, water/coolant temperature indicator, battery volt display. (xii) Safety Controls: Engine low lube oil pressure high water temperature and over speeding of engine (xiii) Coupling Arrangement: Flexible coupling, fly wheel to suit flexible coupling. (xiv) Accessories: AVM Pads built in enclosure and for entire unit on platform.

-

-

-

... More
(xv) Base Frame: Should be provided as OEM norms. (xvi) Fuel Tank: Additional fuel tank of capcaity to suit daily service fuel tank made out of 3mm thick (10G) HR sheet top and bottom with caliberated level indicating arrangement, stop cock, drain plug, fuel pump of suitable capacity complete on a common base out side the accoustic enclosure. (xvii) MS pipe line to and from the fuel tank to the DG Set (C) AMF Panel : Factory made inbuilt type control cubical made out of 2mm thick CRCA sheet dust and vermin proof totally enclosed with front opening of 415 Volts, 3 Phase, 4 wire, AC, 50 Hz, including powder coated, copper bus bar of one and half times the rated load of 500 kVA alternator complete with internal wiring with PVC insulated single core copper conductor multi stranded wire of 1100 Volts grade of suitable capacity, fuses, name plates consisting of 4 Pole ACBs 50 KA rated and Contactors of capacity as recommended by the manufacturer. Detachable cable gland plates, all controls, indicators and standardstandard microprocessor based LED/LCD display for indicating voltage, current, frequency, speed, KW, KWH, pf, temperature, battery voltage etc.

-

-

-

... More
(a) Annunciation with indication lamps for: (i) Low lub oil pressure. (ii) High Water Temperature (iii) Engine over speed (iv) Battery low voltage (b) Controls: (i) Load on Indication (ii) Load off indication (iii) Engine start push button (iv) Engine stop push button (v) Fault accept/reset push button (c) Battary Charger: (i) Transformer (ii) Rectifier (iii) Restance (iv) DC Volt meter (v) DC Ammeter (vi) Charger rate selector switch (D) Acoustic Enclosure: Manufactured by OEM suitable for 500 kVA DG Set (i) NAL approved as per CPCB (ii) It should be as per latest rules and regulations of Ministry of Environment and Forest and Pollution Control Board. (iii) The generating set batteries and control panel should be inside the enclosure. (iv) Fuel tank should be out side the enclosure in the sub station building.

-

-

-

... More
(v) Construction details/specification are as follows: (a) Outer body: CRCA sheet of 1.6mm thick (b) Doors: CRCA sheet of 1.6mm thick (c) Sound Insulation: As per OEM Norms (vi) The acoustic should be composite in construction and fully assembled integral unit (vii) The batteries should be placed inside the enclosure beside the DG Set on a suitable insulated platform (viii) The fuel tank is to be located in Sub Station Building and cost of the fuel lines is deemed to be included in the offer (ix) The DG Set should be provided with external emergency stop push button (x) The enclosure should be suitably illuminated by LED lamp fittings (xi) The noise level should be 75 dba at 1m under free field conditions. (xii) The acoustic enclosure parts shall be of powder coated after pre treatment process. The powder coating shade should be Gen Set Green. The base frame should be painted with epoxy based black shade

-

-

-

... More
(E) The coated rate includes excavation, removing of soft/loose soil and PCC, cement concrete foundation, filling and mass concrete 1:2:4 type B2 using 40mm graded stone aggregate, foundation size not less than 4.6x3.0x0.8m for placing of DG Set complete all as specified and directed by the Engineer-in-Charge. Notes:1. The tenderer shall submit the detail, drawing, specification, features to the accepting officer and obtain approval before the procurement of equipment. 2. The tenderer shall make necessary arrangements for predespatch inspection from rep of Accepting Officer. 3. Testing & commissioning certificate shall be obtained from rep. of AO/IEM.

-

-

-

... More
All as per Sl item No.225 above but of capacity 750 kVA

1

-

-

... More
All as per Sl item No.225 above but of capacity 800 kVA

1

-

-

... More
All as per Sl item No.225 above but of capacity 1200 kVA

1

-

-

-

-

-

... More
Design supply, install testing & commissioning goods lift 2000 Kg, speed 0.5 metre/sec, lift with single speed motor 415 volts, 3 phase, AC 50 Hz supply conforming to IS-14665 and as amended, suitable to serve G + 2 (18 mtr Height) upper floors with AC Variable Voltage & Variable Frequency drive (VVVF drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendant, centre opening doors wth door drive (electric motor driven mechanism), sliding stainless steel doors, including automatic rescue device (ARD) system, 3D infra red sensor in full height of door & built in announcing system without hand set, complete all as specified.

6

-

-

... More
(a) Fire man switch (b) Automatic rescue divide (ARD) during power failure including manual operation provision with suitable capacity of battery designed for funning the lift with full load. c) Battery operated emergency light (LED ceiling fitting), alarm (speaker for emergency alarm system to be fixed) and stop button in car with rechargeable arrangement for battery. d) Four sleek circular LED light fitting in false ceiling . e) One Sleek circular PVC heavy duty fan in false ceiling. Make for(c) & (d) : Philips / Bajaj / Havells / Crompton Greaves. f) Aluminum chequered plate (3 mm thick) as flooring joint in chequered plate should not more than one and top covering with PVC flooring complete. g) Non stop button / independent operation. h) Over load warning indicator both audio and visual type with tripping system having relays etc., (overload protecting / tripping system). j) Front landing door of stainless steel mirror finish operations with a minimum time of 10 seconds and up to a maximum time of 30 seconds. k) Car size shall be conforming to IS-3534-1976 and body to be stainless steel of 16 gauge mirror finish with stainless steel hand rail 38 mm hairline finish.

-

-

-

... More
l) Set of three in number limit switches at the bottom and top most position of lift hoist ways as specified in IS. m) Mirror of 4 mm thickness of suitable size as specified. n) Specification plate with complete details . o) Continuous earthling for machine and equipments. p) Steel wire rope of adequate size as per relevant IS and as per manufacturer specifications. q) Other standard fixtures and fitting like guide rails, sheaves, counter weights with guards, buffers, gear unit breaks, control panel, locks, governor, car operational panel, power, control and trailing cables complete. r) Full length display indicator panel. s) Main drives and control shall be of latest, high effective and low power consumption. t) Suitable phase reversal relay shall be provided on the controller to protect lift/ equipment against phase reversal, phase failure and low voltage. u) Stainless steel front opening type landing door & car door with small opening for vision of size 200 mm x 800 mm with toughened glass not less than 8mm thick. Make of Toughened Glass : Safe / Saint Goblin Glass / Modiguard float glass / kesar / Aashi Indian / Atul Tuf / Hindustan pilkington glass works / Trivenin float glass. v) Three-way Intercom connectivity i.e., Ground floor, security post, car cabin and machine room. w) Brail push button to be provided in the lift car.

-

-

-

... More
AIR CONDITIONING

-

-

-

... More
Design, supply, installation, testing and commissioning of Scroll Chiller type Water Cooled Central Air Conditioning Plant with Semi Hermitic Compressor comprising of Flooded type Evaporator, Shell and Tube type Condenser complete with all equipment and accessories of minimum nominal capacity of 3x120 TR each (02 No. working and 01 No. as standby) for Air Conditioning at 20° C to 25° C with Relative Humidity less than 80% ( at 25° C) all as per specifications, with IPLV.SI (IKW/TR) not less than 0.53 required all as per specifications, drawings and with design conditions comprising of the following: Notes: . (Hanger F-2 & Technical Hanger) 1. Design of AC Plant, layout of all eqpts including duct layout shall be catered by NIT/IIT. 2. The tenderer shall submit the detail, drawing, specification, duct layout complete for approval of CWE before the commencement of work. A. COMPRESSORS: Supply, installation, testing and commissioning of floor-mounted compact screw-type chiller machine complete with semi-hermatic twin screw type compressors with independent circuits, water-cooled S/T type condenser, S/T horizontal flooded type evaporator with carbon steel shell and seamless copper tubes with 19mm nitrile rubber insulation, common base frame, interconnected copper refrigerant piping and wiring, vibration isolators, gauge panel, automatic safety controls, flow switch at evaporator and condenser and ozone friendly CFC-free refrigerant gas R-134a/407C. The refrigerant flow control shall use an electronic expansion valve.

1

-

-

... More
The chiller shall be designed for a working pressure of 150 psig and hydraulically tested at 225 psig. A number of properly spaced baffles shall be provided for maintaining optimum water velocity and heat transfer and the tubes shall be adequately supported. B. CHILLERS: Chillers shall be factory AHRI tested at design conditions at 100%, 75%, 50% and 25% load respectively; test certificates shall be produced for all three chillers. The chiller shall be BMS compatible and shall have RS485/RS232 serial communication protocol; the motor shall be suitable for 3-Phase, 415 Volts ± 10%, 50 Hz, AC electric supply; electric panel shall have an IP 54 rating, as per specification and drawings. The chiller shall be as per the approved particular technical specifications and shall meet the following design criteria: (a) Chiller: (i) Chilled Water IN: 12° C, (ii) Chilled Water OUT: 7°C (iii) Fouling Factor: 0.0005 (in FPS units) (iv) Water Flow Rate: 2.67 USgpm/TR (b) Condenser: (i) Condenser Water IN: 32.2° C (ii) Condenser Water OUT: 38° C (iii) Fouling Factor: 0.001 (in FPS units) (iv) Water Flow Rate: 4.25 USgpm/TR (c) Minimum COP (at ARI conditions): 4.15 (d) Condenser Section: Shell and Tube type condenser internally knurled copper tubes. (e) Expansion Valve: Electronic expansion valve should be capable

-

-

-

... More
enough to operate on wider temperature range with energy efficient improvement at part load conditions, as per manufacturer’s specifications (f) Evaporator: Flooded type evaporator all as per manufacturer’s specifications. (g) Safety Protection: Safety protection on low cooling temperature, low oil pressure, high refrigerant pressure, electric leak, compressor overload, high/low voltage and single phasing shall be provided. Automatic control of refrigerant condition and compressor ON/OFF status and loading sequence system shall be provided. (h) Refrigerant: HFC-134 A/HFC-410 A/HFC-407 C of zero ozone depletion potential refrigeration circuits of total capacity as per manufacturers specifications (j) Control: Micro Processor control with LCD interface capable of monitoring all machine operating parameters like suction/discharge pressure, oil pressure, compressor operating hours, set point, air temperature, entering/leaving water temperature etc complete and precisely manages the operation of compressors, expansion devices, fans and of the evaporator/chiller water pump for optimum energy efficiency as per manufacturers specifications.

-

-

-

... More
(C) CONDENSER WATER CIRCULATION SYSTEM: The condenser water circulation system shall be comprising of the following: (i) FRP induced draft cooling tower of total 110% plant working capacity suitable for above plant conditions complete with spray section, honey comb fill, basin, CT fan, TEFC Motor, intake bird screen and other accessories (Technical Specifications as per the manufacturer) (ii) HDPE make up water tank of 5,000 Litres capacity (2 Nos.) installed on PCC/brick staging for makeup water requirement including brass float valve with polyethylene ball, over flow and drain arrangement, incoming connection of GI pipe 50mm bore medium grade from tank to tapping point including necessary cutting of existing pipe line and tapping of branch connections with GI pipe 25mm bore medium grade all as directed (The item rate is inclusive of provisioning all connected incoming pipe lines from existing sources and all outgoing)-01 Job. (iii) Energy saving Split casing type 3 Phase electric driven pump set of 50% capacity and discharge as per capacity of plant working on 415 Volts, AC, FASD starter for re-circulation of condenser water with ribbed rubber vibration isolation pads 02 Nos. (01 No. working and 01 No. as stand by). 100mm dia. pressure gauges on both discharge and suction side of pumps shall be provided at the outlet of each pump. (01 No. working and 01 No. stand by) Note: Pump Casing-Cast Iron, Impeller-Bronze/Cast Iron, Shaft-HSS or as per manufacturer, Material of Seal-Mechanical Seal. The condenser water pumps shall have minimum flow rate of 4.0 US GPM/TON respectively.

-

-

-

... More
(iv) Condenser water MS Class 'B' tubing medium grade of suitable size by electric arc continuous welding, including two coats of synthetic enamel paint over a coat of red oxide primer as per approved colour code fixed on supports, walls, floors etc. for connecting chiller package unit, pump sets and cooling tower, including filters, fittings, valves, pressure gauges, purge cocks at upper most position, blind flanges, strainers with bypass arrangements. (D) CHILLED WATER CIRCULATION SYSTEM: The chilled water circulation system shall be comprising of the following: (i) Energy saving Split casing type 3 phase electric driven pump sets working on 415 Volts, AC for recirculation of chilled water of 50%, plant capacity-2 Nos. (One working and one No standby) including 100mm dia. pressure gauge shall be provided on delivery side of pumps including rubber vibration isolation pads for mounding including all connections complete. Note: Pump casing-Cast iron, Impeller-Bronze/Cast Iron, Shaft-HSS or as per manufacturer, Material of Seal-Mechanical seal. The chilled water pumps shall have minimum flow rate of 2.4 US GPM/TON (ii) Chilled water MS class 'B' tubing medium grade of suitable size, fixed on supports, walls, floors etc for connecting chiller package units, pump sets, AHUs including fittings, valves, pressure gauges, purge cocks at upper most position, blind flanges, strainers joined by electric arc continuous welding all joints sealed with bitumen, laced with chilled water piping insulated with 50mm thick EPS pipe section of TF quality of density 16 KG/Cu.m. and then cladded with aluminium sheet of 28 SWG thick or plastering using sand cement 15mm thick in two layers over chicken wire mesh where buried under earth.

-

-

-

... More
(iii) HDPE /PVC expansion tank of 2000 Litres capacity including pipe connections and insulation with 50mm thick fibre glass wool covered with chicken wire mesh of density of 24 KG/Cu.m. finished with sand cement plaster including civil works and painting with 3 coats of cement based paint and necessary piping, control valves on inlets and wash out, float valve etc.-01 No. (E) AIR TREATMENT SYSTEM: The air treatment system shall be comprising of the following: (a) Design, supply, Installation, testing and commissioning factory made high static double skinned horizontal type backward curved Air Handling Unit (AHU) with minimum 50mm static pressure with suitable CFM with 0.6mm thick pre coated outer skin & 0.6mm thick inner skin made out of GI sheet not less than 22 gauge. The insulation with 25mm thick PUF panels. The AHUs will be floor mounting (with anti-vibration pads) for cooling the air with all accessories and controls comprising the following including painting etc as per standard practice: Notes: (i) Static pressure may vary according to the design. (ii) The same should be got approved by the Accepting officer and along with the number of AHU's and its CFM also. (b) SITC hot water generator of suitable capacity for re-heat in monsoon. (c) Acoustic Insulation with 25mm thick fibre glass rigid boards and finished with RP tissue paper and 28mm gauge aluminium perforated sheet up to 5m from outlet of the air plenum including 5 micron filters in air plenum for all AHUs all as specified and directed. (d) Fresh air damper with GI bowl/fittings and mosquito proof netting shall be provided for each AHU.

-

-

-

... More
(e) Under deck insulation in AHU Rooms with Fire Retardant XLPE closed cell of thickness 18mm with metalized polyester film and self adhesive backing with protection peel off paper. (F) AIR DISTRIBUTION SYSTEM: The air distribution system shall be comprising of the following: (i) Supply & Return Air ducting factory made out of commercial grade GI sheet zinc coating 120 grade, IS-277 and factory fabricated as per SMACNA-1995 standards and IS-655, but not less than 22 SWG thick. Ducting wherever passing through un-conditioned space shall be insulated with resin bonded Fibre Glass Wool 25mm thick (density 24 KG/Cu.m.) covered with GI chicken wire mesh and cladded with aluminium foil fixed with adhesive tape. Where these ducts are exposed to the sky these will be insulated with 50mm thick fibre glass wool density 24 KG/Cu.m., covered with polythene sheet faced Hessian cloth, GI chicken wire mesh and cladded with sand cement plaster-1 Job (ii) Aluminium powder coated double deflection adjustable type Supply air grills/diffusers with MS volume control dampers and aluminium powder coated fixed bar type return air grills/diffusers as required without volume control damper, for return air-1 Job (iii) Strip type Heater bank of suitable capacity in three banks as required to achieve design conditions with necessary copper conductor wiring for banking complete for each AHU

-

-

-

... More
(iv) Fire dampers automatic type UL stamped fusible plug (CBRI Certified) and operated with stainless steel spring made out of 16 SWG GI sheet and limit switch to be provided in each main supply air duct near plenum in AHU room for each AHU and interlocked with AHU motor to cut off circulation of air in case of fire-01 Job (G) ELECTRICAL DISTRIBUTION SYSTEM: The electrical distribution system shall be comprising of the following: (i) Main Electrical Panel Board: Cubicle type floor mounted, vermin proof, dust proof as per IE standards, powder coated switch board panel made out of CRCA sheet not less than 2mm thick powder coated paint suitable for operation on 415 Volts, 50 Hz, AC supply internally wired with copper conductor wire comprising of the following: (a) TPN Copper bus bar of suitable rating. (b) Main incoming ACB four wire and 35 KA rupturing capacity and outgoing 25 KA MCCBs of suitable capacity. (c) One electronic Energy meter of suitable capacity at main incoming (d) Voltmeter for 0-500 Volts digital type meter (e) Ammeter of required rating digital type (f) LED indicating lamps (g) FASD Starters with suitable rating/size, contactors, relays, SPP and glow type push button switches for compressor, chiller pump and humidifier etc. (h) Provision of insulating Mat Class A, 2mm thick as per IS-15652 (Technical specification as per Annexure ‘A’), first Aid box & Shock treatment chart (Mat at all locations as directed by Engineer-in-Charge). (j) Provision of Suitable heavy duty power capacitors to maintain PF value not less than 0.98 lagging.

-

-

-

... More
(ii) Electrical Panel Board for AHUs: Cubicle type floor mounted, vermin proof, dust proof as per IE standards, powder coated switch board panel made out of CRCA sheet not less than 2mm thick powder coated paint suitable for operation on 415 Volts, 50 Hz, AC supply internally wired with copper conductor wire comprising of the following: (a) TPN Copper Busbar of suitable rating. (b) Main incoming MCCB of 25 KA rupturing capacity and suitable outgoing for AHU motor HWG and humidifier (c) Voltmeter for 0-500 Volts digital type meter (d) Ammeter of required rating digital type (e) LED indicating lamps (f) Starters with suitable rating/size, contactors, relays, SPP and glow type push button switches for AHU motor. (H) Cabling: Necessary cable connection from main electrical panel to AHU, chilled machines, pump sets etc., i.e. for all the equipment in AC plant room and AHU motor, shall be with unarmoured copper conductor cables. The cables shall be laid in masonry trenches or overhead on cable trays on suitable supports at any distances shall be deemed to be included in the quoted rate. The department will provide only power supply source for taking the connection to the panel board in plant room. (J) Control Wiring: Refrigeration control wiring with copper conductor, PVC insulated, unsheathed, multistranded, 1100 Volts grade, single core of size 1.5 Sq.mm. drawn in and including PVC conduit of suitable size for interlocking arrangement as per standard practice with thermostat, humidistat, balancing valve, blower motor, pumps, starter etc., all as directed shall deemed to be included in the quoted rate.

-

-

-

... More
(K) Earthing: Earthing of electric equipments with galvanised steel earth plate electrode 600x600x6mm buried directly in ground earth pit not less than 2.25m deep below normal ground level, connecting to and including GI strip 32x6mm (Up to the body of the equipment) by means of two GI bolts/nuts/ washers. Earth plate shall be surrounded by packed layers of charcoal dust and common salt 15cm thick all around bottom and top and watering pipe 50mm dia. projected 30cm above the GL with one socket and removal GI plug on top and 2.25 meters light grade perforated galvanised steel top with socket and plug and bottom connected to earth plate by slit and two bolts/nuts/washers. Earth strip shall be protected by 40mm bore GI light grade pipe to test point/equipment all as directed including Earth work, GI pipe etc., minimum 16 Jobs is deemed to be included in the quoted rate. Notes:1. The Contractor shall submit heat load calculations as per data sheet & building drawings enclosed with tender and design of Central Air Conditioning system along with the drawings, specifications for compressors, condenser water system with cooling tower, chilled water system, hot water generator supply system complete with pipelines, valves, controls etc. with proper colour coding and supply & return air duct with fire dampers as per STEC pamphlets complete. The design shall be carried out through consultant approved by E-in-C’s branch or CE EC or CE (Navy) Vizag duly vetted by IIT/NITs. The design shall be got approved by rep of AO/CWE before execution of work within 06 (six) months from date of acceptance. The minimum tonnage capacity of plant shall not be less than2x25 TR (1x25 TR as Working & 1x25 TR as Standby). For any higher variation in capacity of plant i.e. compressors with all connected accessories up to air distribution system as per approved design and no price adjustment shall be claimed and the rate quoted shall be deemed to be included for the same.

-

-

-

... More
2. All civil works required to install, test and commissioning the equipment such as earth work excavation, RCC foundation for equipment, necessary cable ducts with MS covers 10mm thick duly painted, earth work excavation for laying pipe, cable etc & making good all disturbed/broken surfaces to match existing surface including fixing the ducting, painting/distemper/colour wash etc. shall be deemed to be included in the rate quoted by the contractor. 3. Necessary water supply pipe connections for the Expansion tank and A/C plant from existing water supply connection is deemed to be included in the quoted rate. 4. All three phase motors shall provided independent single phasing preventor with phase reversal protection. 5. Manufacturers, Technical back up after sales service support shall be provided for chiller package. 6. Suitable supports for holding the ducts and pipes will be provided by tenderer as specified and directed. The tenderer shall also examine at site the method of provision of supply ducts from AHU to entry of the building and inside the conditioned space and any columns/beams/angle iron frames etc. if required to support the ducts grills is deemed to be included in the quoted rate. 7. All loads up to 63 Amps shall be controlled by MCB and MCCB for loads above 63 Amps. 8. Perforated GI sheet cable tray 100mm width fixed on angle iron supports grouted in wall for carrying all cables shall be deemed to be included in the quoted rate. 9. Initial charging of oil and refrigerant shall be deemed to be included in the quoted rate. 10 Velocity of air in supply air duct shall not exceed 450m/minute (1500 FPM) and velocity at diffuser outlet shall not exceed 150m/minute (500 FPM)

-

-

-

... More
10 Velocity of air in supply air duct shall not exceed 450m/minute (1500 FPM) and velocity at diffuser outlet shall not exceed 150m/minute (500 FPM) 11. Necessary drain connection at AHU room and AC plant room shall be provided by the tenderer and shall be deemed to be included in the quoted rate. 12. Any work not included in the above details, but is an inescapable technical requirement for the efficient performance and smooth functioning of the plant shall be clearly specified and included in the offer. 11. Necessary drain connection at AHU room and AC plant room shall be provided by the tenderer and shall be deemed to be included in the quoted rate. 12. Any work not included in the above details, but is an inescapable technical requirement for the efficient performance and smooth functioning of the plant shall be clearly specified and included in the offer. 13. Electric and water supply for Phase-I and Phase-II testing will be provided free of cost by the department. 14. COP (Minimum) for Chillers shall be 4.70. 15. The complete plant is to be installed, tested and commissioned only by the skilled engineer of the original Manufacturer of the chiller-packages. Necessary confirmation is to be submitted by the contractor after completion of the work with test certificates before dept undertakes further testing as per tender and cost is deemed to be included in the quoted rate. 16. All Equipment shall be connected with earth strip of size 32x6mm is deemed to be included in the quoted rate.

-

-

-

... More
17. Phase-II Summer, Monsoon & Winter tests shall be carried out as specified in the Particular Specifications and testing officer to be nominated by accepting officer. 18. After completion of Phase-I test, the plant shall be continuously run for 24 hours (three shifts of 8 hour each per day) by the contractor by providing services of one operator in each shift of 08 hours till completion of all the Phase-II tests and he shall be liable to carry out all the maintenance or repair or replacement of parts (if any) required during this period and quoted rate shall be deemed to be included for this provision. 19. Removal of all electrical fitting/fixtures from ceiling/wall and re-fixing the same after laying of duct including making good of all dismantled surfaces along with provision of new point wiring (wherever damaged) complete as per existing size etc. 20. Distance marked between Magazine, AHUs and AC plant room on the site plan are approximate. Nothing extra will be paid for variation if any. Contractor shall visit the site to make themselves familiar with working conditions, accessibility of site, availability of materials, location of AHU and length and route of ducting required and other cogent condition etc before quoting the tender. Nothing extra shall be paid consequent to any mistake or misunderstanding or otherwise on this account. 21. The design, erection/installation of AC plant including connected accessories shall be as per CFEES final approval report/STEC pamphlets as specified in PS and the cost for the same is deemed to be included in quoted rate.

-

-

-

... More
22. The rate quoted deemed to be inclusive for nearest higher available capacity of plant as per OEM recommendations and no extra shall be paid on this account. Note for all:- AC plant design shall be approved from Chief Engineer level before exicuting the work

-

-

-

... More
All as per serial item No.117 but of capacity 3x60 TR each (02 Nos working and 01 No standby).

2

-

-

... More
All as per serial item No.117 but of capacity 3x45 TR each (02 Nos working and 01 No standby).

1

-

-

... More
EOT/ HOT CRANE

-

-

-

... More
Design, fabrication, supply, erection, testing & commissioning of double girder EOT Cranes of 5 Ton Capacity EOT Crane with a Span of 20 m, Height of Lift 6.0 metre with Gantry Rail and DSL System complete all as specified and as directed. Speeds Hoist - 2 m/min Cross travel - 5 m/min Long travel - 10 m/min

1

-

-

... More
Design, fabrication, supply, erection, testing & commissioning of double girder EOT Cranes of 5 Ton Capacity EOT Crane with a Span of 9 m, Height of Lift 6m with Gantry Rail and DSL System complete all as specified and as directed. Speeds Hoist - 2 m/min Cross travel - 5 m/min Long travel - 10 m/min

1

-

-

... More
Design, fabrication, supply, erection, testing & commissioning of double girder EOT Cranes of 5 Ton Capacity EOT Crane with a Span of 50 m, Height of Lift 6.0m with Gantry Rail and DSL System complete all as specified and as directed. Speeds Hoist - 3 m/min Cross travel - 5 m/min Long travel - 10 m/min

2

-

-

... More
Design, fabrication, supply, erection, testing & commissioning of double girder EOT Cranes of 5 Ton Capacity EOT Crane with a Span of 42.5 m, Height of Lift 6.0m with Gantry Rail and DSL System complete all as specified and as directed. Speeds Hoist - 2 m/min Cross travel - 5 m/min Long travel - 10 m/min

1

-

-

... More
SPECIAL POWER SUPPLY

-

-

-

... More
Supply, installation, commissioning and testing static frequency converter 415 Volt A/C 50 cycle input & output voltage 208 Volts + 1% tolerence output, 400Hz, 3 phase, 60 kVA with Programmable Controller for output voltage & Frequency adjustment with password protection complete as per specification given here in below :- Rated power @ 0.8 pf lag: 60kVA INPUT Voltage - Nominal : 400V AC Range : 340 to 460 V AC Frequency- Nominal : 50Hz Range : 47-53Hz Phase : Three AC to AC Efficiency : 92% Rectifier Technology: 12 Pulse Rectifier SCR based fully controlled Power walk in: 10 to 15 secs THDi (input current Harmonic Distortion ): 10% at rated load Input power Factor 0.92lag Galvanic isolation: Inbuilt Galvanic Isolation OUT PUT Voltage - Nominal: 208V AC ( Programmable) Regulation: 1% Frequency - Nominal : 400Hz ( Programmable)

1

-

-

... More
Stability : 0.05% Phase : Three Phase Waveform : Sine Wave Total Harmonic Distortion : 2% on linear load Transient Response: less than +/-8% for 100% step loads Recovery Time: less than 25milli secs to reach within +/-1% of nominal value Load power factor range : 0.8 lag to unity within KW rating Overload Protection: 120% for 30 min., 150% for1min, 200% for 10 cycles. Protections: Input over/under voltage, Input Phase fail, overlad, Output over/under votage,snubber circuits for power devices, over temperature, fuses for semi conductor devices, high speed electronic fuseless tripping for output short circuit Indications: InputON,OutputON, Input abnormal,Output over/Under voltage, overload, overheat Remote Alarm " Potential free contacts for input fault & output trip Metering: 16x2 LCD panel to measure the following: AC input voltage,output voltage, load percentage, input & output frequency GENERAL Operating Temperature : 0 to 45 Deg C (50 Deg C Peak) Storage Temperature : -20 to 45 deg C Relative Humidity : 95% non condensing Cooling : Forced Air using localized cooling technique with multiple fractional HP fans Panel : Welded structure MS Covers 2mm and frame 3mm thick Enclosure protection: IP 55

-

-

-

... More
Cable Entry : Front Bottom Make: Protech Services/Merlin Hawk/Electronika AXA/AE

-

-

-

... More
Supply, installation, commissioning and testing static frequency converter 415 Volt A/C 50 cycle input & output voltage 208 Volts + 1% tolerence output, 400Hz, 3 phase, 45 kVA with Programmable Controller for output voltage & Frequency adjustment with password protection for 2No's each, complete as per specification given here in below :- Rated power @ 0.8 pf lag: 45kVA INPUT Voltage - Nominal : 400V AC Range : 340 to 460 V AC Frequency- Nominal : 50Hz Range : 47-53Hz Phase : Three AC to AC Efficiency : 92% Rectifier Technology: 12 Pulse Rectifier SCR based fully controlled Power walk in: 10 to 15 secs THDi (input current Harmonic Distortion ): 10% at rated load Input power Factor 0.92lag Galvanic isolation: Inbuilt Galvanic Isolation

6

-

-

... More
OUT PUT Voltage - Nominal: 208V AC ( Programmable) Regulation: 1% Frequency - Nominal : 400Hz ( Programmable) Stability : 0.05% Phase : Three Phase Waveform : Sine Wave Total Harmonic Distortion : 2% on linear load Transient Response: less than +/-8% for 100% step loads Recovery Time: less than 25milli secs to reach within +/-1% of nominal value Load power factor range : 0.8 lag to unity within KW rating Overload Protection: 120% for 30 min., 150% for1min, 200% for 10 cycles. Protections: Input over/under voltage, Input Phase fail, overlad, Output over/under votage,snubber circuits for power devices, over temperature, fuses for semi conductor devices, high speed electronic fuseless tripping for output short circuit Indications: InputON,OutputON, Input abnormal,Output over/Under voltage, overload, overheat Remote Alarm " Potential free contacts for input fault & output trip Metering: 16x2 LCD panel to measure the following: AC input voltage,output voltage, load

-

-

-

... More
GENERAL Operating Temperature : 0 to 45 Deg C (50 Deg C Peak) Storage Temperature : -20 to 45 deg C Relative Humidity : 95% non condensing Cooling : Forced Air using localized cooling technique with multiple fractional HP fans Panel : Welded structure MS Covers 2mm and frame 3mm thick Enclosure protection: IP 55 Cable Entry : Front Bottom Make: Protech Services/Merlin Hawk/Electronika AXA/AE

-

-

-

... More
Supply, installation, commissioning and testing static frequency converter 415 Volt A/C 50 cycle input & output voltage 440 Volts + 1% tolerence output, 400Hz, 3 phase, 100 kVA with Programmable Controller for output voltage & Frequency adjustment with password protection for 2No's each complete as per specification given here in below :- Rated power @ 0.8 pf lag: 100kVA INPUT Voltage - Nominal : 400V AC Range : 340 to 460 V AC Frequency- Nominal : 50Hz Range : 47-53Hz Phase : Three AC to AC Efficiency : 92% Rectifier Technology: 12 Pulse Rectifier SCR based fully controlled Power walk in: 10 to 15 secs THDi (input current Harmonic Distortion ): 10% at rated load Input power Factor 0.92lag Galvanic isolation: Inbuilt Galvanic Isolation

6

-

-

... More
OUT PUT Voltage - Nominal: 440V AC ( Programmable) Regulation: 1% Frequency - Nominal : 400Hz ( Programmable) Stability : 0.05% Phase : Three Phase Waveform : Sine Wave Total Harmonic Distortion : 2% on linear load Transient Response: less than +/-8% for 100% step loads Recovery Time: less than 25milli secs to reach within +/-1% of nominal value Load power factor range : 0.8 lag to unity within KW rating Overload Protection: 120% for 30 min., 150% for1min, 200% for 10 cycles. Protections: Input over/under voltage, Input Phase fail, overlad, Output over/under votage,snubber circuits for power devices, over temperature, fuses for semi conductor devices, high speed electronic fuseless tripping for output short circuit Indications: InputON,OutputON, Input abnormal,Output over/Under voltage, overload, overheat Remote Alarm " Potential free contacts for input fault & output trip Metering: 16x2 LCD panel to measure the following: AC input voltage,output voltage, load percentage, input & output frequency

-

-

-

... More
GENERAL Operating Temperature : 0 to 45 Deg C (50 Deg C Peak) Storage Temperature : -20 to 45 deg C Relative Humidity : 95% non condensing Cooling : Forced Air using localized cooling technique with multiple fractional HP fans Panel : Welded structure MS Covers 2mm and frame 3mm thick Enclosure protection: IP 55 Cable Entry : Front Bottom Make: Protech Services/Merlin Hawk/Electronika AXA/AE

-

-

-

... More
Supply, installation, commissioning and testing static frequency converter 415 Volt A/C 50 cycle input & output voltage 115 Volts + 1% tolerence output, 400Hz, 1 phase, 8kVA with Programmable Controller for output voltage & Frequency adjustment with password protection complete as per specification given here in below :- Rated power @ 0.8 pf lag: 8kVA INPUT Voltage - Nominal : 400V AC Range : 340 to 460 V AC Frequency- Nominal : 50Hz Phase : Three AC to AC Efficiency : 92% Rectifier Technology: 12 Pulse Rectifier SCR based fully controlled Power walk in: 10 to 15 secs THDi (input current Harmonic Distortion ): 10% at rated load Input power Factor 0.92lag Galvanic isolation: Inbuilt Galvanic Isolation

1

-

-

... More
OUT PUT Voltage - Nominal: 115 V AC ( Programmable) Regulation: 1% Frequency - Nominal : 400Hz ( Programmable) Stability : 0.05% Phase : Single Phase Waveform : Sine Wave Total Harmonic Distortion : 2% on linear load Transient Response: less than +/-8% for 100% step loads Recovery Time: less than 25milli secs to reach within +/-1% of nominal value Load power factor range : 0.8 lag to unity within KW rating Overload Protection: 120% for 30 min., 150% for1min, 200% for 10 cycles. Protections: Input over/under voltage, Input Phase fail, overlad, Output over/under votage,snubber circuits for power devices, over temperature, fuses for semi conductor devices, high speed electronic fuseless tripping for output short circuit Indications: InputON,OutputON, Input abnormal,Output over/Under voltage, overload, overheat Remote Alarm " Potential free contacts for input fault & output trip Metering: 16x2 LCD panel to measure the following: AC input voltage,output voltage, load percentage, input & output frequency GENERAL Operating Temperature : 0 to 45 Deg C (50 Deg C Peak) Storage Temperature : -20 to 45 deg C Relative Humidity : 95% non condensing Cooling : Forced Air using localized cooling technique with multiple fractional HP fans

-

-

-

... More
Panel : Welded structure MS Covers 2mm and frame 3mm thick Enclosure protection: IP 55 Cable Entry : Front Bottom Make: Protech Services/Merlin Hawk/Electronika AXA/AE

-

-

-

... More
Supply, installation, commissioning and testing static frequency converter 415 Volt A/C 50 cycle input & output voltage 115 Volts + 1% tolerence output, 400Hz, 1 phase, 5kVA with Programmable Controller for output voltage & Frequency adjustment with password protection complete as per specification given here in below :- Rated power @ 0.8 pf lag: 5kVA INPUT Voltage - Nominal : 400V AC Range : 340 to 460 V AC Frequency- Nominal : 50Hz Range : 47-53Hz Phase : Three AC to AC Efficiency : 92% Rectifier Technology: 12 Pulse Rectifier SCR based fully controlled Power walk in: 10 to 15 secs THDi (input current Harmonic Distortion ): 10% at rated load Input power Factor 0.92lag Galvanic isolation: Inbuilt Galvanic Isolation

1

-

-

... More
OUT PUT Voltage - Nominal: 115 V AC ( Programmable) Regulation: 1% Frequency - Nominal : 400Hz ( Programmable) Stability : 0.05% Phase : Single Phase Waveform : Sine Wave Total Harmonic Distortion : 2% on linear load Transient Response: less than +/-8% for 100% step loads Recovery Time: less than 25milli secs to reach within +/-1% of nominal value Load power factor range : 0.8 lag to unity within KW rating Overload Protection: 120% for 30 min., 150% for1min, 200% for 10 cycles. Protections: Input over/under voltage, Input Phase fail, overlad, Output over/under votage,snubber circuits for power devices, over temperature, fuses for semi conductor devices, high speed electronic fuseless tripping for output short circuit Indications: InputON,OutputON, Input abnormal,Output over/Under voltage, overload, overheat Remote Alarm " Potential free contacts for input fault & output trip

-

-

-

... More
Metering: 16x2 LCD panel to measure the following: AC input voltage,output voltage, load percentage, input & output frequency GENERAL Operating Temperature : 0 to 45 Deg C (50 Deg C Peak) Storage Temperature : -20 to 45 deg C Relative Humidity : 95% non condensing Cooling : Forced Air using localized cooling technique with multiple fractional HP fans Panel : Welded structure MS Covers 2mm and frame 3mm thick Enclosure protection: IP 55 Cable Entry : Front Bottom Make: Protech Services/Merlin Hawk/Electronika AXA/AE

-

-

-

... More
Supply, installation, commissioning and testing static frequency converter 415 Volt A/C 50 cycle input & output voltage 115 Volts + 1% tolerence output, 400Hz, 1 phase, 15kVA with Programmable Controller for output voltage & Frequency adjustment with password protection 2 No's each complete as per specification given here in below :- Rated power @ 0.8 pf lag: 15kVA INPUT Voltage - Nominal : 400V AC Range : 340 to 460 V AC Frequency- Nominal : 50Hz Range : 47-53Hz Phase : Three AC to AC Efficiency : 92% Rectifier Technology: 12 Pulse Rectifier SCR based fully controlled Power walk in: 10 to 15 secs THDi (input current Harmonic Distortion ): 10% at rated load Input power Factor 0.92lag Galvanic isolation: Inbuilt Galvanic Isolation

1

-

-

... More
OUT PUT Voltage - Nominal: 115 V AC ( Programmable) Regulation: 1% Frequency - Nominal : 400Hz ( Programmable) Stability : 0.05% Phase : Single Phase Waveform : Sine Wave Total Harmonic Distortion : 2% on linear load Transient Response: less than +/-8% for 100% step loads Recovery Time: less than 25milli secs to reach within +/-1% of nominal value Load power factor range : 0.8 lag to unity within KW rating Overload Protection: 120% for 30 min., 150% for1min, 200% for 10 cycles. Protections: Input over/under voltage, Input Phase fail, overlad, Output over/under votage,snubber circuits for power devices, over temperature, fuses for semi conductor devices, high speed electronic fuseless tripping for output short circuit Indications: InputON,OutputON, Input abnormal,Output over/Under voltage, overload, overheat Remote Alarm " Potential free contacts for input fault & output trip Metering: 16x2 LCD panel to measure the following: AC input voltage,output voltage, load percentage, input & output frequency GENERAL Operating Temperature : 0 to 45 Deg C (50 Deg C Peak) Storage Temperature : -20 to 45 deg C Relative Humidity : 95% non condensing Cooling : Forced Air using localized cooling technique with multiple fractional HP fans

-

-

-

... More
Panel : Welded structure MS Covers 2mm and frame 3mm thick Enclosure protection: IP 55 Cable Entry : Front Bottom Make: Protech Services/Merlin Hawk/Electronika AXA/AE

-

-

-

... More
Supply, installation, commissioning and testing static frequency converter 415 Volt A/C 50 cycle input & output voltage 115 Volts + 1% tolerence output, 400Hz, 1 phase, 16 kVA with Programmable Controller for output voltage & Frequency adjustment with password protection complete as per specification given here in below :- Rated power @ 0.8 pf lag: 16kVA INPUT Voltage - Nominal : 400V AC Range : 340 to 460 V AC Frequency- Nominal : 50Hz Range : 47-53Hz Phase : Three AC to AC Efficiency : 92% Rectifier Technology: 12 Pulse Rectifier SCR based fully controlled Power walk in: 10 to 15 secs THDi (input current Harmonic Distortion ): 10% at rated load Input power Factor 0.92lag Galvanic isolation: Inbuilt Galvanic Isolation

1

-

-

... More
OUT PUT Voltage - Nominal: 115 V AC ( Programmable) Regulation: 1% Frequency - Nominal : 400Hz ( Programmable) Stability : 0.05% Phase : Single Phase Waveform : Sine Wave Total Harmonic Distortion : 2% on linear load Transient Response: less than +/-8% for 100% step loads Recovery Time: less than 25milli secs to reach within +/-1% of nominal value Load power factor range : 0.8 lag to unity within KW rating Overload Protection: 120% for 30 min., 150% for1min, 200% for 10 cycles. Protections: Input over/under voltage, Input Phase fail, overlad, Output over/under votage,snubber circuits for power devices, over temperature, fuses for semi conductor devices, high speed electronic fuseless tripping for output short circuit Indications: InputON,OutputON, Input abnormal,Output over/Under voltage, overload, overheat Remote Alarm " Potential free contacts for input fault & output trip Metering: 16x2 LCD panel to measure the following: AC input voltage,output voltage, load percentage, input & output frequency GENERAL Operating Temperature : 0 to 45 Deg C (50 Deg C Peak) Storage Temperature : -20 to 45 deg C Relative Humidity : 95% non condensing Cooling : Forced Air using localized cooling technique with multiple fractional HP fans

-

-

-

... More
Panel : Welded structure MS Covers 2mm and frame 3mm thick Enclosure protection: IP 55 Cable Entry : Front Bottom Make: Protech Services/Merlin Hawk/Electronika AXA/AE

-

-

-

... More
Supply, installation, commissioning and testing static frequency converter 415 Volt A/C 50 cycle input & output voltage 115 Volts + 1% tolerence output, 400Hz, 1 phase, 25 kVA with Programmable Controller for output voltage & Frequency adjustment with password protection for Technical Hanger ( Second Floor, Left Side) complete as per specification given here in below :- Rated power @ 0.8 pf lag: 25kVA INPUT Voltage - Nominal : 400V AC Range : 340 to 460 V AC Frequency- Nominal : 50Hz Range : 47-53Hz Phase : Three AC to AC Efficiency : 92% Rectifier Technology: 12 Pulse Rectifier SCR based fully controlled Power walk in: 10 to 15 secs THDi (input current Harmonic Distortion ): 10% at rated load Input power Factor 0.92lag Galvanic isolation: Inbuilt Galvanic Isolation

1

-

-

... More
OUT PUT Voltage - Nominal: 115 V AC ( Programmable) Regulation: 1% Frequency - Nominal : 400Hz ( Programmable) Stability : 0.05% Phase : Single Phase Waveform : Sine Wave Total Harmonic Distortion : 2% on linear load Transient Response: less than +/-8% for 100% step loads Recovery Time: less than 25milli secs to reach within +/-1% of nominal value Load power factor range : 0.8 lag to unity within KW rating Overload Protection: 120% for 30 min., 150% for1min, 200% for 10 cycles. Protections: Input over/under voltage, Input Phase fail, overlad, Output over/under votage,snubber circuits for power devices, over temperature, fuses for semi conductor devices, high speed electronic fuseless tripping for output short circuit Indications: InputON,OutputON, Input abnormal,Output over/Under voltage, overload, overheat Remote Alarm " Potential free contacts for input fault & output trip Metering: 16x2 LCD panel to measure the following: AC input voltage,output voltage, load percentage, input & output frequency GENERAL Operating Temperature : 0 to 45 Deg C (50 Deg C Peak) Storage Temperature : -20 to 45 deg C Relative Humidity : 95% non condensing Cooling : Forced Air using localized cooling technique with multiple fractional HP fans

-

-

-

... More
Panel : Welded structure MS Covers 2mm and frame 3mm thick Enclosure protection: IP 55 Cable Entry : Front Bottom Make: Protech Services/Merlin Hawk/Electronika AXA/AE

-

-

-

... More
Supply, installation, commissioning and testing static frequency converter 220Volt A/C 50 cycle input & output voltage 36 Volts + 1% tolerence output, 50Hz, 1 phase, 1kVA with Programmable Controller for output voltage & Frequency adjustment with password protection complete as per specification given here in below :- Rated power @ 0.8 pf lag: 1kVA INPUT Voltage - Nominal : 220V AC Range : 140 to 270 V AC Frequency- Nominal : 50Hz Range : 47-53Hz Phase : Single AC to AC Efficiency : 92% Rectifier Technology: 12 Pulse Rectifier SCR based fully controlled Power walk in: 10 to 15 secs THDi (input current Harmonic Distortion ): 10% at rated load Input power Factor 0.92lag Galvanic isolation: Inbuilt Galvanic Isolation

1

-

-

... More
OUT PUT Voltage - Nominal: 36 V AC ( Programmable) Regulation: 1% Frequency - Nominal : 50Hz ( Programmable) Stability : 0.05% Phase : Single Phase Waveform : Sine Wave Total Harmonic Distortion : 2% on linear load Transient Response: less than +/-8% for 100% step loads Recovery Time: less than 25milli secs to reach within +/-1% of nominal value Load power factor range : 0.8 lag to unity within KW rating Overload Protection: 120% for 30 min., 150% for1min, 200% for 10 cycles. Protections: Input over/under voltage, Input Phase fail, overlad, Output over/under votage,snubber circuits for power devices, over temperature, fuses for semi conductor devices, high speed electronic fuseless tripping for output short circuit Indications: InputON,OutputON, Input abnormal,Output over/Under voltage, overload, overheat Remote Alarm " Potential free contacts for input fault & output trip Metering: 16x2 LCD panel to measure the following: AC input voltage,output voltage, load percentage, input & output frequency GENERAL Operating Temperature : 0 to 45 Deg C (50 Deg C Peak) Storage Temperature : -20 to 45 deg C Relative Humidity : 95% non condensing Cooling : Forced Air using localized cooling technique with multiple fractional HP fans

-

-

-

... More
Panel : Welded structure MS Covers 2mm and frame 3mm thick Enclosure protection: IP 55 Cable Entry : Front Bottom Make: Protech Services/Merlin Hawk/Electronika AXA/AE

-

-

-

... More
Supply, installation, commissioning and testing static frequency converter 220Volt A/C 50 cycle input & output voltage 36 Volts + 1% tolerence output, 50Hz, 1 phase, 2kVA with Programmable Controller for output voltage & Frequency adjustment with password protection complete as per specification given here in below :- Rated power @ 0.8 pf lag: 2kVA INPUT Voltage - Nominal : 220V AC Range : 140 to 270 V AC Frequency- Nominal : 50Hz Range : 47-53Hz Phase : Single AC to AC Efficiency : 92% Rectifier Technology: 12 Pulse Rectifier SCR based fully controlled Power walk in: 10 to 15 secs THDi (input current Harmonic Distortion ): 10% at rated load Input power Factor 0.92lag Galvanic isolation: Inbuilt Galvanic Isolation

6

-

-

... More
OUT PUT Voltage - Nominal: 36 V AC ( Programmable) Regulation: 1% Frequency - Nominal : 50Hz ( Programmable) Stability : 0.05% Phase : Single Phase Waveform : Sine Wave Total Harmonic Distortion : 2% on linear load Transient Response: less than +/-8% for 100% step loads Recovery Time: less than 25milli secs to reach within +/-1% of nominal value Load power factor range : 0.8 lag to unity within KW rating Overload Protection: 120% for 30 min., 150% for1min, 200% for 10 cycles. Protections: Input over/under voltage, Input Phase fail, overlad, Output over/under votage,snubber circuits for power devices, over temperature, fuses for semi conductor devices, high speed electronic fuseless tripping for output short circuit Indications: InputON,OutputON, Input abnormal,Output over/Under voltage, overload, overheat Remote Alarm " Potential free contacts for input fault & output trip Metering: 16x2 LCD panel to measure the following: AC input voltage,output voltage, load percentage, input & output frequency GENERAL Operating Temperature : 0 to 45 Deg C (50 Deg C Peak) Storage Temperature : -20 to 45 deg C Relative Humidity : 95% non condensing Cooling : Forced Air using localized cooling technique with multiple fractional HP fans

-

-

-

... More
Panel : Welded structure MS Covers 2mm and frame 3mm thick Enclosure protection: IP 55 Cable Entry : Front Bottom Make: Protech Services/Merlin Hawk/Electronika AXA/AE

-

-

-

... More
Supply, installation, commissioning and testing static frequency converter 220Volt A/C 50 cycle input & output voltage 36 Volts + 1% tolerence output, 50Hz, 1 phase, 3kVA with Programmable Controller for output voltage & Frequency adjustment with password protection complete as per specification given here in below :- Rated power @ 0.8 pf lag: 3kVA INPUT Voltage - Nominal : 220V AC Range : 140 to 270 V AC Frequency- Nominal : 50Hz Range : 47-53Hz Phase : Single AC to AC Efficiency : 92% Rectifier Technology: 12 Pulse Rectifier SCR based fully controlled Power walk in: 10 to 15 secs THDi (input current Harmonic Distortion ): 10% at rated load Input power Factor 0.92lag Galvanic isolation: Inbuilt Galvanic Isolation

1

-

-

... More
OUT PUT Voltage - Nominal: 36 V AC ( Programmable) Regulation: 1% Frequency - Nominal : 50Hz ( Programmable) Stability : 0.05% Phase : Single Phase Waveform : Sine Wave Total Harmonic Distortion : 2% on linear load Transient Response: less than +/-8% for 100% step loads Recovery Time: less than 25milli secs to reach within +/-1% of nominal value Load power factor range : 0.8 lag to unity within KW rating Overload Protection: 120% for 30 min., 150% for1min, 200% for 10 cycles. Protections: Input over/under voltage, Input Phase fail, overlad, Output over/under votage,snubber circuits for power devices, over temperature, fuses for semi conductor devices, high speed electronic fuseless tripping for output short circuit Indications: InputON,OutputON, Input abnormal,Output over/Under voltage, overload, overheat Remote Alarm " Potential free contacts for input fault & output trip Metering: 16x2 LCD panel to measure the following: AC input voltage,output voltage, load percentage, input & output frequency GENERAL Operating Temperature : 0 to 45 Deg C (50 Deg C Peak) Storage Temperature : -20 to 45 deg C Relative Humidity : 95% non condensing Cooling : Forced Air using localized cooling technique with multiple fractional HP fans

-

-

-

... More
Panel : Welded structure MS Covers 2mm and frame 3mm thick Enclosure protection: IP 55 Cable Entry : Front Bottom Make: Protech Services/Merlin Hawk/Electronika AXA/AE

-

-

-

... More
Supply, installation, commissioning and testing static frequency converter 220Volt A/C 50 cycle input & output voltage 36 Volts + 1% tolerence output, 50Hz, 1 phase, 4kVA with Programmable Controller for output voltage & Frequency adjustment with password protection complete as per specification given here in below :- Rated power @ 0.8 pf lag: 4kVA INPUT Voltage - Nominal : 220V AC Range : 140 to 270 V AC Frequency- Nominal : 50Hz Range : 47-53Hz Phase : Single AC to AC Efficiency : 92% Rectifier Technology: 12 Pulse Rectifier SCR based fully controlled Power walk in: 10 to 15 secs THDi (input current Harmonic Distortion ): 10% at rated load Input power Factor 0.92lag Galvanic isolation: Inbuilt Galvanic Isolation

1

-

-

... More
OUT PUT Voltage - Nominal: 36 V AC ( Programmable) Regulation: 1% Frequency - Nominal : 50Hz ( Programmable) Stability : 0.05% Phase : Single Phase Waveform : Sine Wave Total Harmonic Distortion : 2% on linear load Transient Response: less than +/-8% for 100% step loads Recovery Time: less than 25milli secs to reach within +/-1% of nominal value Load power factor range : 0.8 lag to unity within KW rating Overload Protection: 120% for 30 min., 150% for1min, 200% for 10 cycles. Protections: Input over/under voltage, Input Phase fail, overlad, Output over/under votage,snubber circuits for power devices, over temperature, fuses for semi conductor devices, high speed electronic fuseless tripping for output short circuit Indications: InputON,OutputON, Input abnormal,Output over/Under voltage, overload, overheat Remote Alarm " Potential free contacts for input fault & output trip Metering: 16x2 LCD panel to measure the following: AC input voltage,output voltage, load percentage, input & output frequency GENERAL Operating Temperature : 0 to 45 Deg C (50 Deg C Peak) Storage Temperature : -20 to 45 deg C Relative Humidity : 95% non condensing Cooling : Forced Air using localized cooling technique with multiple fractional HP fans

-

-

-

... More
Panel : Welded structure MS Covers 2mm and frame 3mm thick Enclosure protection: IP 55 Cable Entry : Front Bottom Make: Protech Services/Merlin Hawk/Electronika AXA/AE

-

-

-

... More
Supply, installation, commissioning and testing static frequency converter 220Volt A/C 50 cycle input & output voltage 36 Volts + 1% tolerence output, 50Hz, 1 phase, 7.5kVA with Programmable Controller for output voltage & Frequency adjustment with password protection complete as per specification given here in below :- Rated power @ 0.8 pf lag: 7.5kVA INPUT Voltage - Nominal : 220V AC Range : 140 to 270 V AC Frequency- Nominal : 50Hz Range : 47-53Hz Phase : Single AC to AC Efficiency : 92% Rectifier Technology: 12 Pulse Rectifier SCR based fully controlled Power walk in: 10 to 15 secs THDi (input current Harmonic Distortion ): 10% at rated load Input power Factor 0.92lag Galvanic isolation: Inbuilt Galvanic Isolation

1

-

-

... More
OUT PUT Voltage - Nominal: 36 V AC ( Programmable) Regulation: 1% Frequency - Nominal : 50Hz ( Programmable) Stability : 0.05% Phase : Single Phase Waveform : Sine Wave Total Harmonic Distortion : 2% on linear load Transient Response: less than +/-8% for 100% step loads Recovery Time: less than 25milli secs to reach within +/-1% of nominal value Load power factor range : 0.8 lag to unity within KW rating Overload Protection: 120% for 30 min., 150% for1min, 200% for 10 cycles. Protections: Input over/under voltage, Input Phase fail, overlad, Output over/under votage,snubber circuits for power devices, over temperature, fuses for semi conductor devices, high speed electronic fuseless tripping for output short circuit Indications: InputON,OutputON, Input abnormal,Output over/Under voltage, overload, overheat Remote Alarm " Potential free contacts for input fault & output trip Metering: 16x2 LCD panel to measure the following: AC input voltage,output voltage, load percentage, input & output frequency GENERAL Operating Temperature : 0 to 45 Deg C (50 Deg C Peak) Storage Temperature : -20 to 45 deg C Relative Humidity : 95% non condensing Cooling : Forced Air using localized cooling technique with multiple fractional HP fans

-

-

-

... More
Panel : Welded structure MS Covers 2mm and frame 3mm thick Enclosure protection: IP 55 Cable Entry : Front Bottom Make: Protech Services/Merlin Hawk/Electronika AXA/AE

-

-

-

... More
Supply, installation, commissioning and testing static frequency converter 220Volt A/C 50 cycle input & output voltage 36 Volts + 1% tolerence output, 400Hz, 1 phase, 1kVA with Programmable Controller for output voltage & Frequency adjustment with password protection complete as per specification given here in below :- Rated power @ 0.8 pf lag: 1kVA INPUT Voltage - Nominal : 220V AC Range : 140 to 270 V AC Frequency- Nominal : 50Hz Range : 47-53Hz Phase : Single AC to AC Efficiency : 92% Rectifier Technology: 12 Pulse Rectifier SCR based fully controlled Power walk in: 10 to 15 secs THDi (input current Harmonic Distortion ): 10% at rated load Input power Factor 0.92lag Galvanic isolation: Inbuilt Galvanic Isolation

1

-

-

... More
OUT PUT Voltage - Nominal: 36 V AC ( Programmable) Regulation: 1% Frequency - Nominal : 50Hz ( Programmable) Stability : 0.05% Phase : Single Phase Waveform : Sine Wave Total Harmonic Distortion : 2% on linear load Transient Response: less than +/-8% for 100% step loads Recovery Time: less than 25milli secs to reach within +/-1% of nominal value Load power factor range : 0.8 lag to unity within KW rating Overload Protection: 120% for 30 min., 150% for1min, 200% for 10 cycles. Protections: Input over/under voltage, Input Phase fail, overlad, Output over/under votage,snubber circuits for power devices, over temperature, fuses for semi conductor devices, high speed electronic fuseless tripping for output short circuit Indications: InputON,OutputON, Input abnormal,Output over/Under voltage, overload, overheat Remote Alarm " Potential free contacts for input fault & output trip Metering: 16x2 LCD panel to measure the following: AC input voltage,output voltage, load percentage, input & output frequency GENERAL Operating Temperature : 0 to 45 Deg C (50 Deg C Peak) Storage Temperature : -20 to 45 deg C Relative Humidity : 95% non condensing Cooling : Forced Air using localized cooling technique with multiple fractional HP fans

-

-

-

... More
Panel : Welded structure MS Covers 2mm and frame 3mm thick Enclosure protection: IP 55 Cable Entry : Front Bottom Make: Protech Services/Merlin Hawk/Electronika AXA/AE

-

-

-

... More
Supply, installation, commissioning and testing static frequency converter 415 Volt A/C 50 cycle input & output voltage 36Volts + 1% tolerence output, 400Hz, 3 phase, 2kVA with Programmable Controller for output voltage & Frequency adjustment with password protection complete 2No's each as per specification given here in below :- Rated power @ 0.8 pf lag: 2kVA INPUT Voltage - Nominal : 400V AC Range : 340 to 460 V AC Frequency- Nominal : 50Hz Range : 47-53Hz Phase : Single AC to AC Efficiency : 92% Rectifier Technology: 12 Pulse Rectifier SCR based fully controlled Power walk in: 10 to 15 secs THDi (input current Harmonic Distortion ): 10% at rated load Input power Factor 0.92lag Galvanic isolation: Inbuilt Galvanic Isolation

6

-

-

... More
OUT PUT Voltage - Nominal: 36 V AC ( Programmable) Regulation: 1% Frequency - Nominal : 50Hz ( Programmable) Stability : 0.05% Phase : Single Phase Waveform : Sine Wave Total Harmonic Distortion : 2% on linear load Transient Response: less than +/-8% for 100% step loads Recovery Time: less than 25milli secs to reach within +/-1% of nominal value Load power factor range : 0.8 lag to unity within KW rating Overload Protection: 120% for 30 min., 150% for1min, 200% for 10 cycles. Protections: Input over/under voltage, Input Phase fail, overlad, Output over/under votage,snubber circuits for power devices, over temperature, fuses for semi conductor devices, high speed electronic fuseless tripping for output short circuit Indications: InputON,OutputON, Input abnormal,Output over/Under voltage, overload, overheat Remote Alarm " Potential free contacts for input fault & output trip Metering: 16x2 LCD panel to measure the following: AC input voltage,output voltage, load percentage, input & output frequency GENERAL Operating Temperature : 0 to 45 Deg C (50 Deg C Peak) Storage Temperature : -20 to 45 deg C Relative Humidity : 95% non condensing Cooling : Forced Air using localized cooling technique with multiple fractional HP fans

-

-

-

... More
Panel : Welded structure MS Covers 2mm and frame 3mm thick Enclosure protection: IP 55 Cable Entry : Front Bottom Make: Protech Services/Merlin Hawk/Electronika AXA/AE

-

-

-

... More
Supply, installation, commissioning and testing static frequency converter 415 Volt A/C 50 cycle input & output voltage 36Volts + 1% tolerence output, 400Hz, 3 phase, 5kVA with Programmable Controller for output voltage & Frequency adjustment with password protection complete as per specification given here in below :- Rated power @ 0.8 pf lag: 5kVA INPUT Voltage - Nominal : 400V AC Range : 340 to 460 V AC Frequency- Nominal : 50Hz Range : 47-53Hz Phase : Single AC to AC Efficiency : 92% Rectifier Technology: 12 Pulse Rectifier SCR based fully controlled Power walk in: 10 to 15 secs THDi (input current Harmonic Distortion ): 10% at rated load Input power Factor 0.92lag Galvanic isolation: Inbuilt Galvanic Isolation

1

-

-

... More
OUT PUT Voltage - Nominal: 36 V AC ( Programmable) Regulation: 1% Frequency - Nominal : 50Hz ( Programmable) Stability : 0.05% Phase : Single Phase Waveform : Sine Wave Total Harmonic Distortion : 2% on linear load Transient Response: less than +/-8% for 100% step loads Recovery Time: less than 25milli secs to reach within +/-1% of nominal value Load power factor range : 0.8 lag to unity within KW rating Overload Protection: 120% for 30 min., 150% for1min, 200% for 10 cycles. Protections: Input over/under voltage, Input Phase fail, overlad, Output over/under votage,snubber circuits for power devices, over temperature, fuses for semi conductor devices, high speed electronic fuseless tripping for output short circuit Indications: InputON,OutputON, Input abnormal,Output over/Under voltage, overload, overheat Remote Alarm " Potential free contacts for input fault & output trip Metering: 16x2 LCD panel to measure the following: AC input voltage,output voltage, load percentage, input & output frequency GENERAL Operating Temperature : 0 to 45 Deg C (50 Deg C Peak) Storage Temperature : -20 to 45 deg C Relative Humidity : 95% non condensing Cooling : Forced Air using localized cooling technique with multiple fractional HP fans

-

-

-

... More
Panel : Welded structure MS Covers 2mm and frame 3mm thick Enclosure protection: IP 55 Cable Entry : Front Bottom Make: Protech Services/Merlin Hawk/Electronika AXA/AE

-

-

-

... More
Supply, installation, commissioning and testing static frequency converter 415 Volt A/C 50 cycle input & output voltage 27Volts + 1% tolerence output, 400Hz, 3 phase, 2kVA with Programmable Controller for output voltage & Frequency adjustment with password protection complete 2No. each complete as per specification given here in below :- Rated power @ 0.8 pf lag: 2kVA INPUT Voltage - Nominal : 400V AC Range : 340 to 460 V AC Frequency- Nominal : 50Hz Range : 47-53Hz Phase : Single AC to AC Efficiency : 92% Rectifier Technology: 12 Pulse Rectifier SCR based fully controlled Power walk in: 10 to 15 secs THDi (input current Harmonic Distortion ): 10% at rated load Input power Factor 0.92lag Galvanic isolation: Inbuilt Galvanic Isolation

6

-

-

... More
OUT PUT Voltage - Nominal: 36 V AC ( Programmable) Regulation: 1% Frequency - Nominal : 50Hz ( Programmable) Stability : 0.05% Phase : Single Phase Waveform : Sine Wave Total Harmonic Distortion : 2% on linear load Transient Response: less than +/-8% for 100% step loads Recovery Time: less than 25milli secs to reach within +/-1% of nominal value Load power factor range : 0.8 lag to unity within KW rating Overload Protection: 120% for 30 min., 150% for1min, 200% for 10 cycles. Protections: Input over/under voltage, Input Phase fail, overlad, Output over/under votage,snubber circuits for power devices, over temperature, fuses for semi conductor devices, high speed electronic fuseless tripping for output short circuit Indications: InputON,OutputON, Input abnormal,Output over/Under voltage, overload, overheat Remote Alarm " Potential free contacts for input fault & output trip Metering: 16x2 LCD panel to measure the following: AC input voltage,output voltage, load percentage, input & output frequency GENERAL Operating Temperature : 0 to 45 Deg C (50 Deg C Peak) Storage Temperature : -20 to 45 deg C Relative Humidity : 95% non condensing Cooling : Forced Air using localized cooling technique with multiple fractional HP fans

-

-

-

... More
Panel : Welded structure MS Covers 2mm and frame 3mm thick Enclosure protection: IP 55 Cable Entry : Front Bottom Make: Protech Services/Merlin Hawk/Electronika AXA/AE

-

-

-

... More
Supply, installation, commissioning and testing static voltage converter 415 Volt A/C 50 cycle input & output voltage 380 Volts + 1% tolerence output, 50Hz, 1 phase, 50 kVA with Programmable Controller for output voltage & Frequency adjustment with password protection for 2No's each in complete as per specification given here in below :- Rated power @ 0.8 pf lag: 50kVA INPUT Voltage - Nominal : 400V AC Range : 340 to 460 V AC Frequency- Nominal : 50Hz Range : 47-53Hz Phase : Single AC to AC Efficiency : 92% Rectifier Technology: 12 Pulse Rectifier SCR based fully controlled Power walk in: 10 to 15 secs THDi (input current Harmonic Distortion ): 10% at rated load Input power Factor 0.92lag Galvanic isolation: Inbuilt Galvanic Isolation

6

-

-

... More
OUT PUT Voltage - Nominal: 36 V AC ( Programmable) Regulation: 1% Frequency - Nominal : 50Hz ( Programmable) Stability : 0.05% Phase : Single Phase Waveform : Sine Wave Total Harmonic Distortion : 2% on linear load Transient Response: less than +/-8% for 100% step loads Recovery Time: less than 25milli secs to reach within +/-1% of nominal value Load power factor range : 0.8 lag to unity within KW rating Overload Protection: 120% for 30 min., 150% for1min, 200% for 10 cycles. Protections: Input over/under voltage, Input Phase fail, overlad, Output over/under votage,snubber circuits for power devices, over temperature, fuses for semi conductor devices, high speed electronic fuseless tripping for output short circuit Indications: InputON,OutputON, Input abnormal,Output over/Under voltage, overload, overheat Remote Alarm " Potential free contacts for input fault & output trip Metering: 16x2 LCD panel to measure the following: AC input voltage,output voltage, load percentage, input & output frequency GENERAL Operating Temperature : 0 to 45 Deg C (50 Deg C Peak) Storage Temperature : -20 to 45 deg C Relative Humidity : 95% non condensing Cooling : Forced Air using localized cooling technique with multiple fractional HP fans

-

-

-

... More
Panel : Welded structure MS Covers 2mm and frame 3mm thick Enclosure protection: IP 55 Cable Entry : Front Bottom Make: Protech Services/Merlin Hawk/Electronika AXA/AE

-

-

-

... More
Supply, installation, commissioning and testing 1kVA Static DC Power Supply 220 Volt A/C 50 cycle input & 27 VDC +1% tolerence output with Programmable Controller for Output Voltage with Password Protection2No. each complete specification given here in below :- Rated power @ 0.8 pf lag : 27V DC, 1kVA INPUT Voltage - Nominal : 220V AC Range : 140 - 280V AC Frequency- Nominal : 50Hz Range : 47-53Hz Phase : Single AC to AC Efficiency : 92% Rectifier Technology: 12 Pulse Rectifier SCR based fully controlled Power walk in: 10 to 15 secs THDi (input current Harmonic Distortion ): 10% at rated load Input power Factor 0.92lag Galvanic isolation: Inbuilt Galvanic Isolation

6

-

-

... More
OUT PUT Voltage - Nominal: 36 V AC ( Programmable) Regulation: 1% Frequency - Nominal : 50Hz ( Programmable) Stability : 0.05% Phase : Single Phase Waveform : Sine Wave Total Harmonic Distortion : 2% on linear load Transient Response: less than +/-8% for 100% step loads Recovery Time: less than 25milli secs to reach within +/-1% of nominal value Load power factor range : 0.8 lag to unity within KW rating Overload Protection: 120% for 30 min., 150% for1min, 200% for 10 cycles. Protections: Input over/under voltage, Input Phase fail, overlad, Output over/under votage,snubber circuits for power devices, over temperature, fuses for semi conductor devices, high speed electronic fuseless tripping for output short circuit Indications: InputON,OutputON, Input abnormal,Output over/Under voltage, overload, overheat Remote Alarm " Potential free contacts for input fault & output trip Metering: 16x2 LCD panel to measure the following: AC input voltage,output voltage, load percentage, input & output frequency GENERAL Operating Temperature : 0 to 45 Deg C (50 Deg C Peak) Storage Temperature : -20 to 45 deg C Relative Humidity : 95% non condensing Cooling : Forced Air using localized cooling technique with multiple fractional HP fans

-

-

-

... More
Panel : Welded structure MS Covers 2mm and frame 3mm thick Enclosure protection: IP 55 Cable Entry : Front Bottom Make: Protech Services/Merlin Hawk/Electronika AXA/AE

-

-

-

... More
Supply, installation, commissioning and testing 12KW Static DC Power Supply 415 Volt A/C 50 cycle input & 27 VDC +1% tolerence output with Programmable Controller for Output Voltage with Password Protection with complete specification given here in below :- Rated power @ 0.8 pf lag : 27V DC, 12KW INPUT Voltage - Nominal : 400V Range : 340 - 480V Ac Frequency- Nominal : 50Hz Range : 47-53Hz Phase : Single AC to AC Efficiency : 92% Rectifier Technology: 12 Pulse Rectifier SCR based fully controlled Power walk in: 10 to 15 secs THDi (input current Harmonic Distortion ): 10% at rated load Input power Factor 0.92lag Galvanic isolation: Inbuilt Galvanic Isolation

9

-

-

... More
OUT PUT Voltage - Nominal: 36 V AC ( Programmable) Regulation: 1% Frequency - Nominal : 50Hz ( Programmable) Stability : 0.05% Phase : Single Phase Waveform : Sine Wave Total Harmonic Distortion : 2% on linear load Transient Response: less than +/-8% for 100% step loads Recovery Time: less than 25milli secs to reach within +/-1% of nominal value Load power factor range : 0.8 lag to unity within KW rating Overload Protection: 120% for 30 min., 150% for1min, 200% for 10 cycles. Protections: Input over/under voltage, Input Phase fail, overlad, Output over/under votage,snubber circuits for power devices, over temperature, fuses for semi conductor devices, high speed electronic fuseless tripping for output short circuit Indications: InputON,OutputON, Input abnormal,Output over/Under voltage, overload, overheat Remote Alarm " Potential free contacts for input fault & output trip Metering: 16x2 LCD panel to measure the following: AC input voltage,output voltage, load percentage, input & output frequency GENERAL Operating Temperature : 0 to 45 Deg C (50 Deg C Peak) Storage Temperature : -20 to 45 deg C Relative Humidity : 95% non condensing Cooling : Forced Air using localized cooling technique with multiple fractional HP fans

-

-

-

... More
Panel : Welded structure MS Covers 2mm and frame 3mm thick Enclosure protection: IP 55 Cable Entry : Front Bottom Make: Protech Services/Merlin Hawk/Electronika AXA/AE

-

-

-

... More
Supply, installation, commissioning and testing 9kVA Static DC Power Supply 415 Volt A/C 50 cycle input & 27 VDC +1% tolerence output with Programmable Controller for Output Voltage with Password Protection with complete specification given here in below :- Rated power @ 0.8 pf lag : 27V DC, 9kVA INPUT Voltage - Nominal : 400V Range : 340 - 480V Ac Frequency- Nominal : 50Hz Range : 47-53Hz Phase : Single AC to AC Efficiency : 92% Rectifier Technology: 12 Pulse Rectifier SCR based fully controlled Power walk in: 10 to 15 secs THDi (input current Harmonic Distortion ): 10% at rated load Input power Factor 0.92lag Galvanic isolation: Inbuilt Galvanic Isolation

1

-

-

... More
OUT PUT Voltage - Nominal: 36 V AC ( Programmable) Regulation: 1% Frequency - Nominal : 50Hz ( Programmable) Stability : 0.05% Phase : Single Phase Waveform : Sine Wave Total Harmonic Distortion : 2% on linear load Transient Response: less than +/-8% for 100% step loads Recovery Time: less than 25milli secs to reach within +/-1% of nominal value Load power factor range : 0.8 lag to unity within KW rating Overload Protection: 120% for 30 min., 150% for1min, 200% for 10 cycles. Protections: Input over/under voltage, Input Phase fail, overlad, Output over/under votage,snubber circuits for power devices, over temperature, fuses for semi conductor devices, high speed electronic fuseless tripping for output short circuit Indications: InputON,OutputON, Input abnormal,Output over/Under voltage, overload, overheat Remote Alarm " Potential free contacts for input fault & output trip Metering: 16x2 LCD panel to measure the following: AC input voltage,output voltage, load percentage, input & output frequency GENERAL Operating Temperature : 0 to 45 Deg C (50 Deg C Peak) Storage Temperature : -20 to 45 deg C Relative Humidity : 95% non condensing Cooling : Forced Air using localized cooling technique with multiple fractional HP fans

-

-

-

... More
Panel : Welded structure MS Covers 2mm and frame 3mm thick Enclosure protection: IP 55 Cable Entry : Front Bottom Make: Protech Services/Merlin Hawk/Electronika AXA/AE

-

-

-

... More
Supply, installation, commissioning and testing 5KW Static DC Power Supply 415 Volt A/C 50 cycle input & 27 VDC +1% tolerence output with Programmable Controller for Output Voltage with Password Protection with complete specification given here in below :- Rated power @ 0.8 pf lag : 27V DC, 5 KW INPUT Voltage - Nominal : 400V Range : 340 - 480V Ac Frequency- Nominal : 50Hz Range : 47-53Hz Phase : Single AC to AC Efficiency : 92% Rectifier Technology: 12 Pulse Rectifier SCR based fully controlled Power walk in: 10 to 15 secs THDi (input current Harmonic Distortion ): 10% at rated load Input power Factor 0.92lag Galvanic isolation: Inbuilt Galvanic Isolation

1

-

-

... More
OUT PUT Voltage - Nominal: 36 V AC ( Programmable) Regulation: 1% Frequency - Nominal : 50Hz ( Programmable) Stability : 0.05% Phase : Single Phase Waveform : Sine Wave Total Harmonic Distortion : 2% on linear load Transient Response: less than +/-8% for 100% step loads Recovery Time: less than 25milli secs to reach within +/-1% of nominal value Load power factor range : 0.8 lag to unity within KW rating Overload Protection: 120% for 30 min., 150% for1min, 200% for 10 cycles. Protections: Input over/under voltage, Input Phase fail, overlad, Output over/under votage,snubber circuits for power devices, over temperature, fuses for semi conductor devices, high speed electronic fuseless tripping for output short circuit Indications: InputON,OutputON, Input abnormal,Output over/Under voltage, overload, overheat Remote Alarm " Potential free contacts for input fault & output trip Metering: 16x2 LCD panel to measure the following: AC input voltage,output voltage, load percentage, input & output frequency GENERAL Operating Temperature : 0 to 45 Deg C (50 Deg C Peak) Storage Temperature : -20 to 45 deg C Relative Humidity : 95% non condensing Cooling : Forced Air using localized cooling technique with multiple fractional HP fans

-

-

-

... More
Panel : Welded structure MS Covers 2mm and frame 3mm thick Enclosure protection: IP 55 Cable Entry : Front Bottom Make: Protech Services/Merlin Hawk/Electronika AXA/AE

-

-

-

... More
Supply, installation, commissioning and testing 10kVA Static DC Power Supply 415 Volt A/C 50 cycle input & 27 VDC +1% tolerence output with Programmable Controller for Output Voltage with Password Protection with complete specification given here in below :- Rated power @ 0.8 pf lag : 27V DC, 10kVA INPUT Voltage - Nominal : 400V Range : 340 - 480V Ac Frequency- Nominal : 50Hz Range : 47-53Hz Phase : Single AC to AC Efficiency : 92% Rectifier Technology: 12 Pulse Rectifier SCR based fully controlled Power walk in: 10 to 15 secs THDi (input current Harmonic Distortion ): 10% at rated load Input power Factor 0.92lag Galvanic isolation: Inbuilt Galvanic Isolation

1

-

-

... More
OUT PUT Voltage - Nominal: 36 V AC ( Programmable) Regulation: 1% Frequency - Nominal : 50Hz ( Programmable) Stability : 0.05% Phase : Single Phase Waveform : Sine Wave Total Harmonic Distortion : 2% on linear load Transient Response: less than +/-8% for 100% step loads Recovery Time: less than 25milli secs to reach within +/-1% of nominal value Load power factor range : 0.8 lag to unity within KW rating Overload Protection: 120% for 30 min., 150% for1min, 200% for 10 cycles. Protections: Input over/under voltage, Input Phase fail, overlad, Output over/under votage,snubber circuits for power devices, over temperature, fuses for semi conductor devices, high speed electronic fuseless tripping for output short circuit Indications: InputON,OutputON, Input abnormal,Output over/Under voltage, overload, overheat Remote Alarm " Potential free contacts for input fault & output trip Metering: 16x2 LCD panel to measure the following: AC input voltage,output voltage, load percentage, input & output frequency GENERAL Operating Temperature : 0 to 45 Deg C (50 Deg C Peak) Storage Temperature : -20 to 45 deg C Relative Humidity : 95% non condensing Cooling : Forced Air using localized cooling technique with multiple fractional HP fans

-

-

-

... More
Panel : Welded structure MS Covers 2mm and frame 3mm thick Enclosure protection: IP 55 Cable Entry : Front Bottom Make: Protech Services/Merlin Hawk/Electronika AXA/AE

-

-

-

... More
Supply, installation, commissioning and testing 18kVA Static DC Power Supply 415 Volt A/C 50 cycle input & 27 VDC +1% tolerence output with Programmable Controller for Output Voltage with Password Protection with complete specification given here in below :- Rated power @ 0.8 pf lag : 27V DC, 18kVA INPUT Voltage - Nominal : 400V Range : 340 - 480V Ac Frequency- Nominal : 50Hz Range : 47-53Hz Phase : Single AC to AC Efficiency : 92% Rectifier Technology: 12 Pulse Rectifier SCR based fully controlled Power walk in: 10 to 15 secs THDi (input current Harmonic Distortion ): 10% at rated load Input power Factor 0.92lag Galvanic isolation: Inbuilt Galvanic Isolation

1

-

-

... More
OUT PUT Voltage - Nominal: 36 V AC ( Programmable) Regulation: 1% Frequency - Nominal : 50Hz ( Programmable) Stability : 0.05% Phase : Single Phase Waveform : Sine Wave Total Harmonic Distortion : 2% on linear load Transient Response: less than +/-8% for 100% step loads Recovery Time: less than 25milli secs to reach within +/-1% of nominal value Load power factor range : 0.8 lag to unity within KW rating Overload Protection: 120% for 30 min., 150% for1min, 200% for 10 cycles. Protections: Input over/under voltage, Input Phase fail, overlad, Output over/under votage,snubber circuits for power devices, over temperature, fuses for semi conductor devices, high speed electronic fuseless tripping for output short circuit Indications: InputON,OutputON, Input abnormal,Output over/Under voltage, overload, overheat Remote Alarm " Potential free contacts for input fault & output trip Metering: 16x2 LCD panel to measure the following: AC input voltage,output voltage, load percentage, input & output frequency GENERAL Operating Temperature : 0 to 45 Deg C (50 Deg C Peak) Storage Temperature : -20 to 45 deg C Relative Humidity : 95% non condensing Cooling : Forced Air using localized cooling technique with multiple fractional HP fans

-

-

-

... More
Panel : Welded structure MS Covers 2mm and frame 3mm thick Enclosure protection: IP 55 Cable Entry : Front Bottom Make: Protech Services/Merlin Hawk/Electronika AXA/AE

-

-

-

... More
Supply, installation, commissioning and testing 30kVA Static DC Power Supply 415 Volt A/C 50 cycle input & 27 VDC +1% tolerence output with Programmable Controller for Output Voltage with Password Protection with complete specification given here in below :- Rated power @ 0.8 pf lag : 27V DC, 30kVA INPUT Voltage - Nominal : 400V Range : 340 - 480V Ac Frequency- Nominal : 50Hz Range : 47-53Hz Phase : Single AC to AC Efficiency : 92% Rectifier Technology: 12 Pulse Rectifier SCR based fully controlled Power walk in: 10 to 15 secs THDi (input current Harmonic Distortion ): 10% at rated load Input power Factor 0.92lag Galvanic isolation: Inbuilt Galvanic Isolation

1

-

-

... More
OUT PUT Voltage - Nominal: 36 V AC ( Programmable) Regulation: 1% Frequency - Nominal : 50Hz ( Programmable) Stability : 0.05% Phase : Single Phase Waveform : Sine Wave Total Harmonic Distortion : 2% on linear load Transient Response: less than +/-8% for 100% step loads Recovery Time: less than 25milli secs to reach within +/-1% of nominal value Load power factor range : 0.8 lag to unity within KW rating Overload Protection: 120% for 30 min., 150% for1min, 200% for 10 cycles. Protections: Input over/under voltage, Input Phase fail, overlad, Output over/under votage,snubber circuits for power devices, over temperature, fuses for semi conductor devices, high speed electronic fuseless tripping for output short circuit Indications: InputON,OutputON, Input abnormal,Output over/Under voltage, overload, overheat Remote Alarm " Potential free contacts for input fault & output trip Metering: 16x2 LCD panel to measure the following: AC input voltage,output voltage, load percentage, input & output frequency GENERAL Operating Temperature : 0 to 45 Deg C (50 Deg C Peak) Storage Temperature : -20 to 45 deg C Relative Humidity : 95% non condensing Cooling : Forced Air using localized cooling technique with multiple fractional HP fans

-

-

-

... More
Panel : Welded structure MS Covers 2mm and frame 3mm thick Enclosure protection: IP 55 Cable Entry : Front Bottom Make: Protech Services/Merlin Hawk/Electronika AXA/AE

-

-

-

... More
Supply, installation, commissioning and testing of 40 kVA Special AC Power Supply Single Phase I/p - Single Phase O/p Electro Mechanical Type comprising of Motorized Dimmerstat, Buck-Boost Transformer, AC Step- Synchronous Motor, solid state electronic control circuits with switching Triacs & Surge Suppresion provision complete as per specification given here in below :- System Construction : Conforming to IS:9815-1994 INPUT Voltage - Nominal : 230 VAC Range : 140 to 280 V AC Frequency- Nominal : 50Hz Range : 45-60Hz Phase : Single

1

-

-

... More
OUT PUT Voltage - 220+/- 1%, 1Ph, 2 wire Frequency- 50Hz Speed of Correction: Voltage Correction Rate60V/Sec Insulation Resistance: Above 5M Ohms at 500V DC, Class-H High Voltage: Can withstand 2.5kV for 5 Sec Dielectric Strength: 1.5kV rms for 1 minute Power Loss: Max 2% Efficiency: Not less than 98% Duty Cycle: 100% continuous Load PF: There should be no effect to output due to load PF Response Time: Less than 20mSec Metering: Digital AC Voltmeter for Input & OutputVoltage & AC Ammeter for output current. Operation: Auto or Manual Indications: LED indication for Input Voltage, High/Low & Overload Protections: High/Low Voltage Cut off, Overload & Surge Suppresor, Harmonic Filter to reduce THD at output to less than 10%, short circuit Lamination: CRGO lamination with 99% copper By-Pass: Stabiliser By-pass facility to be provided Transformer Oil: Transformer oil should confirm to IS 335, IEC 296 first filling to be provided at the time of supply. Terminations: Input & Output terminations as per IS:3347 Cabling: Input & Output terminations with provision for fixing cable glands. Earthing: with Earth terminals Indications: Input/Output Voltage , input/output current, Frequency, High/Low Voltage with Buzzer, oil level Indicator

-

-

-

... More
Environment Operating Temperature : 0 to 50 Deg C Storage Temperature : -10 to 75 deg C Relative Humidity : 95% non condensing Enclosure Protection: IP 55 Special Features Alarm Lamps in case of Mains Over/Under Voltage Screw driver adjustment to set output voltage Auto - Manual Selector switch to select mode of working Stabiliser should be provided with unidirectional wheels Make: Protech Services/Merlin Hawk/Electronika AXA/AE

-

-

-

... More
Supply, installation, commissioning and testing of 20 kVA Special AC Power Supply Single Phase I/p - Single Phase O/p Electro Mechanical Type comprising of Motorized Dimmerstat, Buck-Boost Transformer, AC Step- Synchronous Motor, solid state electronic control circuits with switching Triacs & Surge Suppresion provision complete as per specification given here in below :- System Construction : Conforming to IS:9815-1994 INPUT Voltage - Nominal : 230 VAC Range : 140 to 280 V AC Frequency- Nominal : 50Hz Range : 45-60Hz Phase : Single

2

-

-

... More
OUT PUT Voltage - 220+/- 1%, 1Ph, 2 wire Frequency- 50Hz Speed of Correction: Voltage Correction Rate60V/Sec Insulation Resistance: Above 5M Ohms at 500V DC, Class-H High Voltage: Can withstand 2.5kV for 5 Sec Dielectric Strength: 1.5kV rms for 1 minute Power Loss: Max 2% Efficiency: Not less than 98% Duty Cycle: 100% continuous Load PF: There should be no effect to output due to load PF Response Time: Less than 20mSec Metering: Digital AC Voltmeter for Input & OutputVoltage & AC Ammeter for output current. Operation: Auto or Manual Indications: LED indication for Input Voltage, High/Low & Overload Protections: High/Low Voltage Cut off, Overload & Surge Suppresor, Harmonic Filter to reduce THD at output to less than 10%, short circuit Lamination: CRGO lamination with 99% copper By-Pass: Stabiliser By-pass facility to be provided Transformer Oil: Transformer oil should confirm to IS 335, IEC 296 first filling to be provided at the time of supply. Terminations: Input & Output terminations as per IS:3347 Cabling: Input & Output terminations with provision for fixing cable glands. Earthing: with Earth terminals Indications: Input/Output Voltage , input/output current, Frequency, High/Low Voltage with Buzzer, oil level Indicator

-

-

-

... More
Environment Operating Temperature : 0 to 50 Deg C Storage Temperature : -10 to 75 deg C Relative Humidity : 95% non condensing Enclosure Protection: IP 55 Special Features Alarm Lamps in case of Mains Over/Under Voltage Screw driver adjustment to set output voltage Auto - Manual Selector switch to select mode of working Stabiliser should be provided with unidirectional wheels Make: Protech Services/Merlin Hawk/Electronika AXA/AE

-

-

-

... More
Supply, installation, commissioning and testing of 10 kVA Special AC Power Supply Single Phase I/p - Single Phase O/p Electro Mechanical Type comprising of Motorized Dimmerstat, Buck-Boost Transformer, AC Step- Synchronous Motor, solid state electronic control circuits with switching Triacs & Surge Suppresion provision complete as per specification given here in below :- INPUT Voltage - Nominal : 230 VAC Range : 140 to 280 V AC Frequency- Nominal : 50Hz Range : 45-60Hz Phase : Single

2

-

-

... More
OUT PUT Voltage - 220+/- 1%, 1Ph, 3 wire Frequency- 50Hz Speed of Correction: Voltage Correction Rate60V/Sec Insulation Resistance: Above 5M Ohms at 500V DC, Class-H High Voltage: Can withstand 2.5kV for 5 Sec Dielectric Strength: 1.5kV rms for 1 minute Power Loss: Max 2% Efficiency: Not less than 98% Duty Cycle: 100% continuous Load PF: There should be no effect to output due to load PF Response Time: Less than 20mSec Metering: Digital AC Voltmeter for Input & OutputVoltage & AC Ammeter for output current. Operation: Auto or Manual Indications: LED indication for Input Voltage, High/Low & Overload Protections: High/Low Voltage Cut off, Overload & Surge Suppresor, Harmonic Filter to reduce THD at output to less than 10%, short circuit Lamination: CRGO lamination with 99% copper By-Pass: Stabiliser By-pass facility to be provided Transformer Oil: Transformer oil should confirm to IS 335, IEC 296 first filling to be provided at the time of supply. Terminations: Input & Output terminations as per IS:3347 Cabling: Input & Output terminations with provision for fixing cable glands. Earthing: with Earth terminals Indications: Input/Output Voltage , input/output current, Frequency, High/Low Voltage with Buzzer, oil level Indicator

-

-

-

... More
Environment Operating Temperature : 0 to 50 Deg C Storage Temperature : -10 to 75 deg C Relative Humidity : 95% non condensing Enclosure Protection: IP 55 Special Features Alarm Lamps in case of Mains Over/Under Voltage Screw driver adjustment to set output voltage Auto - Manual Selector switch to select mode of working Stabiliser should be provided with unidirectional wheels Make: Protech Services/Merlin Hawk/Electronika AXA/AE

-

-

-

... More
Supply, installation, commissioning and testing Uniterrupted Power Supply System 415 Volt A/C 50 cycle input & output voltage 220Volts + 0.5% tolerence output, 50Hz, 3 phase, 30kVA with Programmable Controller for output voltage with password protection, Enclosure Protection IP-55 alongwith SMF Batteries for 30 minutes back up complete as per specification given here in below :- Rated power @ 0.8 pf lag : 27V DC, 30kVA INPUT Voltage - Nominal : 400V Range : 340 - 480V Ac Frequency- Nominal : 50Hz Range : 47-53Hz Phase : Single AC to AC Efficiency : 92% Rectifier Technology: 12 Pulse Rectifier SCR based fully controlled Power walk in: 10 to 15 secs THDi (input current Harmonic Distortion ): 10% at rated load Input power Factor 0.92lag Galvanic isolation: Inbuilt Galvanic Isolation

3

-

-

... More
OUT PUT Voltage - Nominal: 220V AC ( Programmable) Regulation: 1% Frequency - Nominal : 50Hz ( Programmable) Stability : 0.05% Phase : Single Phase Waveform : Sine Wave Total Harmonic Distortion : 2% on linear load Transient Response: less than +/-8% for 100% step loads Recovery Time: less than 25milli secs to reach within +/-1% of nominal value Load power factor range : 0.8 lag to unity within KW rating Overload Protection: 120% for 30 min., 150% for1min, 200% for 10 cycles. Protections: Input over/under voltage, Input Phase fail, overlad, Output over/under votage,snubber circuits for power devices, over temperature, fuses for semi conductor devices, high speed electronic fuseless tripping for output short circuit Indications: InputON,OutputON, Input abnormal,Output over/Under voltage, overload, overheat Remote Alarm " Potential free contacts for input fault & output trip Metering: 16x2 LCD panel to measure the following: AC input voltage,output voltage, load percentage, input & output frequency GENERAL Operating Temperature : 0 to 45 Deg C (50 Deg C Peak) Storage Temperature : -20 to 45 deg C Relative Humidity : 95% non condensing Cooling : Forced Air using localized cooling technique with multiple fractional HP fans

-

-

-

... More
Panel : Welded structure MS Covers 2mm and frame 3mm thick Enclosure protection: IP 55 Cable Entry : Front Bottom Make: Protech Services/Merlin Hawk/Electronika AXA/AE

-

-

-

... More
Supply, installation, commissioning and testing Uniterrupted Power Supply System 415 Volt A/C 50 cycle input & output voltage 220Volts + 0.5% tolerence output, 50Hz, 3 phase, 20kVA with Programmable Controller for output voltage with password protection, Enclosure Protection IP-55 alongwith SMF Batteries for 30 minutes back up for "O' Level, "I" Level, "O" Level & "I" Level complete as per specification given here in below :- Rated power @ 0.8 pf lag: 20 kVA INPUT Voltage - Nominal : 400V Range : 340 - 460V Ac Frequency- Nominal : 50Hz Range : 47-53Hz Phase : Single AC to AC Efficiency : 92% Rectifier Technology: 12 Pulse Rectifier SCR based fully controlled Power walk in: 10 to 15 secs THDi (input current Harmonic Distortion ): 10% at rated load Input power Factor 0.92lag Galvanic isolation: Inbuilt Galvanic Isolation

6

-

-

... More
OUT PUT Voltage - Nominal: 220V AC ( Programmable) Regulation: 1% Frequency - Nominal : 50Hz ( Programmable) Stability : 0.05% Phase : Single Phase Waveform : Sine Wave Total Harmonic Distortion : 2% on linear load Transient Response: less than +/-8% for 100% step loads Recovery Time: less than 25milli secs to reach within +/-1% of nominal value Load power factor range : 0.8 lag to unity within KW rating Overload Protection: 120% for 30 min., 150% for1min, 200% for 10 cycles. Protections: Input over/under voltage, Input Phase fail, overlad, Output over/under votage,snubber circuits for power devices, over temperature, fuses for semi conductor devices, high speed electronic fuseless tripping for output short circuit Indications: InputON,OutputON, Input abnormal,Output over/Under voltage, overload, overheat Remote Alarm " Potential free contacts for input fault & output trip Metering: 16x2 LCD panel to measure the following: AC input voltage,output voltage, load percentage, input & output frequency GENERAL Operating Temperature : 0 to 45 Deg C (50 Deg C Peak) Storage Temperature : -20 to 45 deg C Relative Humidity : 95% non condensing Cooling : Forced Air using localized cooling technique with multiple fractional HP fans

-

-

-

... More
Panel : Welded structure MS Covers 2mm and frame 3mm thick Enclosure protection: IP 55 Cable Entry : Front Bottom Make: Protech Services/Merlin Hawk/Electronika AXA/AE

-

-

-

... More
Supply, installation, commissioning and testing Uniterrupted Power Supply System 415 Volt A/C 50 cycle input & output voltage 220Volts + 0.5% tolerence output, 50Hz, 3 phase, 15kVA with Programmable Controller for output voltage with password protection, Enclosure Protection IP-55 alongwith SMF Batteries for 30 minutes back up for complete as per specification given here in below :- Rated power @ 0.8 pf lag: 15 kVA INPUT Voltage - Nominal : 400V Range : 340 - 460V Ac Frequency- Nominal : 50Hz Range : 47-53Hz Phase : Single AC to AC Efficiency : 92% Rectifier Technology: 12 Pulse Rectifier SCR based fully controlled Power walk in: 10 to 15 secs THDi (input current Harmonic Distortion ): 10% at rated load Input power Factor 0.92lag Galvanic isolation: Inbuilt Galvanic Isolation

2

-

-

... More
OUT PUT Voltage - Nominal: 220V AC ( Programmable) Regulation: 1% Frequency - Nominal : 50Hz ( Programmable) Stability : 0.05% Phase : Single Phase Waveform : Sine Wave Total Harmonic Distortion : 2% on linear load Transient Response: less than +/-8% for 100% step loads Recovery Time: less than 25milli secs to reach within +/-1% of nominal value Load power factor range : 0.8 lag to unity within KW rating Overload Protection: 120% for 30 min., 150% for1min, 200% for 10 cycles. Protections: Input over/under voltage, Input Phase fail, overlad, Output over/under votage,snubber circuits for power devices, over temperature, fuses for semi conductor devices, high speed electronic fuseless tripping for output short circuit Indications: InputON,OutputON, Input abnormal,Output over/Under voltage, overload, overheat Remote Alarm " Potential free contacts for input fault & output trip Metering: 16x2 LCD panel to measure the following: AC input voltage,output voltage, load percentage, input & output frequency GENERAL Operating Temperature : 0 to 45 Deg C (50 Deg C Peak) Storage Temperature : -20 to 45 deg C Relative Humidity : 95% non condensing Cooling : Forced Air using localized cooling technique with multiple fractional HP fans

-

-

-

... More
Panel : Welded structure MS Covers 2mm and frame 3mm thick Enclosure protection: IP 55 Cable Entry : Front Bottom Make: Protech Services/Merlin Hawk/Electronika AXA/AE

-

-

-

... More
Supply, installation, commissioning and testing Uniterrupted Power Supply System 415 Volt A/C 50 cycle input & output voltage 220Volts + 0.5% tolerence output, 50Hz, 3 phase, 10kVA with Programmable Controller for output voltage with password protection, Enclosure Protection IP-55 alongwith SMF Batteries for 30 minutes back up for complete as per specification given here in below :- Rated power @ 0.8 pf lag: 10 kVA INPUT Voltage - Nominal : 400V Range : 340 - 460V Ac Frequency- Nominal : 50Hz Range : 47-53Hz Phase : Single AC to AC Efficiency : 92% Rectifier Technology: 12 Pulse Rectifier SCR based fully controlled Power walk in: 10 to 15 secs THDi (input current Harmonic Distortion ): 10% at rated load Input power Factor 0.92lag Galvanic isolation: Inbuilt Galvanic Isolation

6

-

-

... More
OUT PUT Voltage - Nominal: 220V AC ( Programmable) Regulation: 1% Frequency - Nominal : 50Hz ( Programmable) Stability : 0.05% Phase : Single Phase Waveform : Sine Wave Total Harmonic Distortion : 2% on linear load Transient Response: less than +/-8% for 100% step loads Recovery Time: less than 25milli secs to reach within +/-1% of nominal value Load power factor range : 0.8 lag to unity within KW rating Overload Protection: 120% for 30 min., 150% for1min, 200% for 10 cycles. Protections: Input over/under voltage, Input Phase fail, overlad, Output over/under votage,snubber circuits for power devices, over temperature, fuses for semi conductor devices, high speed electronic fuseless tripping for output short circuit Indications: InputON,OutputON, Input abnormal,Output over/Under voltage, overload, overheat Remote Alarm " Potential free contacts for input fault & output trip Metering: 16x2 LCD panel to measure the following: AC input voltage,output voltage, load percentage, input & output frequency GENERAL Operating Temperature : 0 to 45 Deg C (50 Deg C Peak) Storage Temperature : -20 to 45 deg C Relative Humidity : 95% non condensing Cooling : Forced Air using localized cooling technique with multiple fractional HP fans

-

-

-

... More
Panel : Welded structure MS Covers 2mm and frame 3mm thick Enclosure protection: IP 55 Cable Entry : Front Bottom Make: Protech Services/Merlin Hawk/Electronika AXA/AE

-

-

-

... More
Supply, installation, commissioning and testing Uniterrupted Power Supply System 415 Volt A/C 50 cycle input & output voltage 220Volts + 0.5% tolerence output, 50Hz, 3 phase, 5kVA with Programmable Controller for output voltage with password protection, Enclosure Protection IP-55 alongwith SMF Batteries for 30 minutes back up for complete as per specification given here in below :- Rated power @ 0.8 pf lag: 5 kVA INPUT Voltage - Nominal : 400V Range : 340 - 460V Ac Frequency- Nominal : 50Hz Range : 47-53Hz Phase : Single AC to AC Efficiency : 92% Rectifier Technology: 12 Pulse Rectifier SCR based fully controlled Power walk in: 10 to 15 secs THDi (input current Harmonic Distortion ): 10% at rated load Input power Factor 0.92lag Galvanic isolation: Inbuilt Galvanic Isolation

3

-

-

... More
OUT PUT Voltage - Nominal: 220V AC ( Programmable) Regulation: 1% Frequency - Nominal : 50Hz ( Programmable) Stability : 0.05% Phase : Single Phase Waveform : Sine Wave Total Harmonic Distortion : 2% on linear load Transient Response: less than +/-8% for 100% step loads Recovery Time: less than 25milli secs to reach within +/-1% of nominal value Load power factor range : 0.8 lag to unity within KW rating Overload Protection: 120% for 30 min., 150% for1min, 200% for 10 cycles. Protections: Input over/under voltage, Input Phase fail, overlad, Output over/under votage,snubber circuits for power devices, over temperature, fuses for semi conductor devices, high speed electronic fuseless tripping for output short circuit Indications: InputON,OutputON, Input abnormal,Output over/Under voltage, overload, overheat Remote Alarm " Potential free contacts for input fault & output trip Metering: 16x2 LCD panel to measure the following: AC input voltage,output voltage, load percentage, input & output frequency GENERAL Operating Temperature : 0 to 45 Deg C (50 Deg C Peak) Storage Temperature : -20 to 45 deg C Relative Humidity : 95% non condensing Cooling : Forced Air using localized cooling technique with multiple fractional HP fans

-

-

-

... More
Panel : Welded structure MS Covers 2mm and frame 3mm thick Enclosure protection: IP 55 Cable Entry : Front Bottom Make: Protech Services/Merlin Hawk/Electronika AXA/AE

-

-

-

... More
S&F Wall/Floor mounted Mains Distribution Panel for Maintenance Hanger F 1, F2, Hawk & Technical Hanger made out of 2mm thick CRCA sheet with V & F digital meters indoor type with following:. Input Side : Copper Bus bar mounted on insulators suitable for 415V,50Hz, 3Ph, 4 wire, 500A, 15 inch long with 7 tap off points, with VIF Meter. Output Side (i) 200A, MCCB, 4P,415V, 25KA "C" curve (for 100kVA, 440V SFC) -01 No. (ii) 100A MCCB, 4P,415V, 25KA "C" Curve (for 45kVA, 208V SFC & 50kVA, 380V/1Ph) -02 Nos. (iii) 26A TPN,MCB,415V, 35KA "C" Curve (for 15kVA, 115V SFC)-01No. (iv) 16A DP,MCB, 220V, 10KA "C" Curve(for 2kVA, 36/3Ph, 2kVA, 27V/3Ph & 1kVA 27VDC )---03No. Switchgear/MCB in panel of Havells/L&T/Siemens Make of Meter & Panel: AE/Protech Services/Merlin Hawk

6

-

-

... More
Supply & Fix wall mounted Output distribution panel made out of 2mm thick CRCA sheet with V & F digital meters for all outputs indoor type for Maintenance Hanger F1& F2, Hawk Hanger & Technical Hanger output suitable to accommodate: (i) 160A,MCCB, 4P, 25 KA"C" Curve . on Input side & 6 ''Copper Bus bar mounted on insulators with 2 tap off points suitable for 440V, 3Ph,400Hz, 4 wire, 200A on output side ( for 100kVA , 440V SFC) (ii) 125A,MCCB, 4P, 35 KA, "C" Curve on Input side & 6'' copper Bus bar mounted on insulators with 2 tap off points suitable for 208V, 3Ph, 400Hz, 4 wire, 150A on output side ( for 45kVA(208V)SFC) (iii) 63A, TPN,10KA on input side & Copper bus bar mounted on Insulators with 2 tap off points suitable for 115V, 1Ph, 400Hz, 2 wire, 150A ( for 15kVA SFC) (iv) 32A TPN, 10KA on input side & 6" Copper bus bar mounted on insulators with 1 tap off point suitable for , 36V/3Ph, 400Hz, 50A, 4 wire ( for 2kVA, 36V/3Ph SFC) Switchgear/MCB in panel of Havells/L&T/Siemens Make of Meter & Panel: AE/Protech Services/Aplab

6

-

-

... More
Supply & Fixing wall mounted boxes made out of 2mm Rick CRCA Sheet indoor type suitable to Accommodate : Input Side : 63A, TPN,MCB, 10 KA C Curve - 3 Nos. 63A, DP,MCB, 10KA, C Curve - 1 No. Output Side : 63A, 3 Pin, Industrial Type Male Female Sockets- 2 Nos. 63A, 5 Pin, Industrial Type Male Female Sockets- 2 Nos. Switchgear/MCB in panel : Havells/ L&T/Seimens. Make of meter & panel : AE/Protech Services/Merlin Hawk

12

-

-

... More
Supply & Fixing wall mounted boxes made out of 2 mm Rick CRCA Sheet indoor type suitable to accommodate Input Side: 32A TPN,MCB, 10KA, C Curve- 2 No. 32 DP,MCB, 10KA, C Curve-1 No. Copper Bus Bar mounted on insulators of 4" Suitable for 40A,2 wire, DC 27V Output side : 32A, 5 Pin, Industrial Type Male Female Sockets -2 No 32A, 3 Pin, Industrial Type Male-Female Sockets- 1 No. Switchgear/MCB in Panel : Havells/L&T/Siemens Make of Meter & panel : A/E/Protech Services/Marlin Hawk

6

-

-

... More
Supply & Fix of wall mounted Mains distribution panel made out of 2mm thick CRCA Sheet indoor type with V&F digital meters comprising of : Input side : 1. 100A MCCB, 4P, 25 KA along with bus bar suitable for 415V, 3 Ph. 4 wire, 50 HZ, 4" Long Output side 1. 40A, TPN,MCB, 10 KA (for 27VDCPS) 2. 26A, TPN,MCB, 10 KA (for 10 kVA UPS) Switchgear/MCB in panel : Havells/ L&T/Seimens. Make of meter & panel : AE/Protech Services/Merlin Hawk

9

-

-

... More
Supply & fixing of floor mounted output panel made out of 2 mm thick CRCA Sheet Indoor type with V & F meters for AC output & V meter for DC O/p comprising of : 1. 250 A MCCB, 4P, 25 KA, along with 4" long bus bar suitable for 600A, 2 wire, 27VDC. 2. 32ADP, 10 KA along with 5A Sockets x 4 No's & I5A Sockets x 2 No's for 220V, 1 Ph. 50 Hz. Switchgear/MCB in panel : Havells/ L&T/Seimens. Make of meter & panel : AE/Protech Services/Merlin Hawk

9

-

-

... More
Supply & Fixing of wall mounted UPS output panel indoor type comprising of 100A, 3P MCB, 25KA along with 8" long bus bar mounted on insulators suitable for 100A, 215V, 1 Ph, 2 wire, 50 Hz complete all as speicified and directed. Switchgear/MCB in panel : Havells/ L&T/Seimens. Make of meter & panel : AE/Protech Services/Merlin Hawk

2

-

-

... More
Supply & Fix wall mounted mains distribution panel made out of 2mm thick CRCA Sheet with V & F digital meters for First floor left side Hawk hanger indoor type comprising of : Input Side 100A, MCCB, 4P, 25KA with bus bar mounted on insulators suitable for 100A, 415V, 4 wire, 50 Hz, 10" Long. Outside : 1. 26A TPN,MCB, 10 KA- 1 No. (for DCPS) 2. 16A TPN,MCB, 10 KA-2 No. (for 115V & 36/3Ph SFC) 3. 16A DP,MCB, 10 KA- 1 No. (for 36/1SFC) 4. 80A DP,MCB, 10 KA-1 No. (for 10 kVA Stab) Switchgear/MCB in panel : Havells/ L&T/Seimens. Make of meter & panel : AE/Protech Services/Merlin Hawk

1

-

-

... More
Supply & Fixing of wall mounted output distribution panel made out of 2 mm thick CRCA Sheet with suitable V & F digital meters for all outputs complete all as specified and directed. Indoor type comprising of : 1. 125A, MCCB, 4P, 25KA alongwith bus bar suitable for 27VDC, 2 wire, 250A- 1 No. (for DCPS) 2. 100A MCCB, 4P, 25 KA along with bus bar suitable for 36V, 3 Ph. 4 wire, 400 Hz, 100A- 1 No(for 36V/3ph SFC) 3.26A TPN, MCB, 10KA, Alongwith bus bar suitable for 115V, 1Ph. 2 wire, 400 Hz, 50A- 1 No. (for 115V SFC) 4. 63A, DP, MCB, 10 KA alongwith bus bar suitable for 36V, 1 Ph. 2 wire, 60A-1 No. (for 36V/1PhSFC) 5. 63A DP, MCB, 10 KA alongwith bus bar suitable for 220V, 1Ph. 2 wire, 60A- 1 No. (for 220V Stab.) Switchgear/MCB in panel : Havells/ L&T/Seimens. Make of meter & panel : AE/Protech Services/Merlin Hawk

1

-

-

... More
Supply & fixing of Bus bar Panel made out of 2mm thick CRCA Sheet indoor type for Radio lab I comprising of 1. Bus Bar mounted on insulator suitable for 150A, 2 wire, 27VDC, 6" long. 2. Bus bar Mounted on insulator suitable for 30A, 2wire 115V, 400 Hz, 6" long. 3. Bus bar Mounted on insulator suitable for 30A, 2 wire, 220 V, 50 Hz 6" long. 4. Bus bar Mounted on insulator suitable for 50A, 4 wire, 3 Ph, 36V, 400 Hz 6:" long. 5. Bus Bar Mounted on insulator suitable for 40A, 2 wire, 1 Ph, 36V AC, 6" long. Switchgear/MCB in panel : Havells/ L&T/Seimens. Make of meter & panel : AE/Protech Services/Merlin Hawk

3

-

-

... More
Supply & Fix of wall/Table mounted supply boxes indoor type (4 No. Rectification lab, 4 No. Radio Section II, & 4 No. for Radio Section I) comprising of: 1. 6A, DP,MCB, 10 KA along with Industrial Type Male Female Socket 16A, 3 Pin (For 115V, 400HZSFC). 2. 32A, DP,MCB, 10 KA alongwith Industrial Type Male Female Socket 32A, 3 Pin (for 27VDC) 3. 16A, TPN,MCB, 10 KA alongwith Industrial Type Male female socket 16A, 5 Pin (for 36V/3Ph SFC) 4. 16A, DP,MCB, 10 KA alongwith Industrial/type Male-Female Socket 16A, 3 Pin for 36V/1Ph. SFC 5. 32A,DP,MCB 10 KA alongwith 16A, 3 Pin, 2 No. sockets. Switchgear/MCB in panel : Havells/ L&T/Seimens. Make of meter & panel : AE/Protech Services/Merlin Hawk

12

-

-

... More
Supply & fixing of wall/floor mounted mains distribution panel made out of 2 mm thick CRCA sheet indoor type comprising of: Incoming Side : 160A, MCCB, 25KA, 4P alongwith Copper Bus bar mounted on insulators suitable for 200A, 415V, 3 Ph. 4 wire, 50 Hz, 8" long, with V & F Digital meters. Outgoing Side 1. 32A TPN,MCB, 10 KA (for 16 kVA, 115V, 1 Ph. SFC) 2. 10A, TPN,MCB, 10 KA (for 4 kVA, 36V, Iph. SFC) 3. 63A, TPN,MCB, 10 KA (for 18 AVA DCPS) 4. 100A, MCCB, 4P,MCB, 25KA (for 40 kVA Stab) Switchgear/MCB in panel : Havells/ L&T/Seimens. Make of meter & panel : AE/Protech Services/Merlin Hawk

1

-

-

... More
Supply & Fixing of output distribution panel wall mounted made out of 2 mm thick CRCA Sheet indoor type with suitable V & F digital meters comprising of 1. 100 A, MCCB,4P, 25KA (for 115V SFC) alongwith copper bus bar mounted on suitable insulators for 150 A, 2 wire, 115V, 400 Hz, 1' long. 2. 63A, TPN,MCB, 10 KA (for 36V/IPh SFC) alongwith copper bus bar mounted on suitable insulators for 120A, 2 wire, 36V, 1Ph, 1' long. 3. 350A, MCCB, 4 P, 35 KA (for 27VDC) alongwith copper bus bar mounted on insulators for 700 A, 2 wire, 27V DC, 1' long. 4. 63A TPN, MCB, 10 KA (for 415VAC) alongwith bus bar mounted on insulators for 70A, 4 wire, 415VAC, 1' long. Switchgear/MCB in panel : Havells/ L&T/Seimens. Make of meter & panel : AE/Protech Services/Merlin Hawk

1

-

-

... More
Supply & Fixing of wall mounted sub output distribution panel comprising of: Bus Bar set mounted on insulator suitable for: 1. 50A, 115V, 1 Ph, 2 wire, 400 Hz, 8" Long. 2. 200A, 27V DC, 2 wire, 8" Long 3. 80A, 220V, 2 wire, 50 Hz, 8" Long. In addition above 63A, 36V, 1 Ph. 400Hz, 2 wire bus bar 8" long needed for room no. 3 only. Suitable Digital V & F meters to be provided. Switchgear/MCB in panel : Havells/ L&T/Seimens. Make of meter & panel : AE/Protech Services/Merlin Hawk

4

-

-

... More
Supply & fixing of wall/table mounted supply box 1. 6A, DP,MCB, 10 KA with 5A x 2 No. Sockets 2. 32A,DP,MCB, 10 KA with 32A, 3 Pin, industrial type male Female connectors 3. 32A, DP,MCB,10KA with 10A x 4 No's sockets. Switchgear/MCB in panel : Havells/ L&T/Seimens. Make of meter & panel : AE/Protech Services/Merlin Hawk

20

-

-

... More
Supply & Fix wall mounted output distribution panel made out of 2 mm thick CRCA Sheet . Indoor type comprising of : 1. 125A, MCCB, 4P, 25KA alongwith copper bus bar suitable for 27VDC, 2 wire, 250A- 1 No. (for DCPS) 2. 100A, MCCB,4P, 25KA along with copper bus bar suitable for 36V, 3 Ph, 4 wire, 400 Hz, 100A- 2 No(for 36V/3Ph SFC) 3.26A, TPN, MCB, 10KA, alongwith bus bar suitable for 115V, 1Ph, 2 wire, 400 Hz, 50A- 1 No. (for 115V/1Ph SFC) 4. 63A, DP MCB 10 KA alongwith bus bar suitable for 36V, 1 Ph. 2 wire, 60A-1 No. (for 36V/1PhSFC) 5. 63A, DP, MCB, 10 KA alongwith bus bar suitable for 220V, 1Ph. 2 wire, 60A- 1 No. (for 220V Stab.) 6. 16A DP 10 KA with 10A x 1 No. Socket. Switchgear/MCB in panel : Havells/ L&T/Seimens. Make of meter & panel : AE/Protech Services/Merlin Hawk

8

-

-

... More
Supply & fix wall/floor mounted mains distribution panel made out of 2 mm thick CRCA Sheet with V & F digital meters indoor type Comprising of: Incoming Side 160A, MCCB, 4P, 25KA alongwith copper bus bar mounted on insulators suitable for 415V, 3 Ph, 4 wire, 50 Hz, 200A, 8" Long. Outgoing Side 1. 100A, MCCB, 4 P, 25KA (for 60 kVA/208V SFC) 2. 16A, TPN,MCB, 10 KA (for 3 kVA/36V, 1 Ph,SFC) 3. 32A, TPN,MCB, 10 KA, (for 10 kVA DCPS) 4. 40A TPN,MCB, 10 KA (for 20 kVA Stab.)

1

-

-

... More
Supply & Fixing of wall/floor mounted output distribution panel made out of 2mm thick CRCA Sheet with V & F digital meters for all outputs indoor type for Second Floor (Right Side) Technical Hanger Comprising of Incoming Side : 1. 200A, MCCB, 4P, 25KA (for 60 kVA, 208V SFC) 2. 80A, DP, MCB, 10 KA (for 3 kVA, 36V/IPh SFC) 3. 200A, MCCB, 4P, 25KA (for 27V DC) 4. 42A, TPN, MCB, 10 KA (for 415V, 3 Ph, Stab.) Outgoing side : 1. Copper bus bar mounted on insulators suitable for 200A, 208V, 3Ph , 4 wire, 400 Hz, 10" Long. 2. Copper bus bar mounted on insulators suitable for 36V, 1 Ph,2 wire, 50 H z, 100A, 10" long. 3. Copper bus mounted on insulators suitable for 200A, 27V, 2 wire, DC, 10" long. 4. Copper bus bar mounted on insulators suitable for 415V, 3 Ph. 4 wire, 50 Hz, 50A, 10" Long. Switchgear/MCB in panel : Havells/ L&T/Seimens. Make of meter & panel : AE/Protech Services/Merlin Hawk

1

-

-

... More
Supply & fixing of panel for Emergency escape facility room I & II (Second floor, Right Side of Technical Hanger) 1. Copper Bus Bar Mounted on insulators suitable for 27V DC, 2 wire, 60A, 6" Long. 2. Copper Bus Bar Mounted on insulators suitable for 36V, 1 Ph, 2 wire, 60 A, 50 Hz, 6 "long. Switchgear/MCB in panel : Havells/ L&T/Seimens. Make of meter & panel : AE/Protech Services/Merlin Hawk

2

-

-

... More
Supply & fixing of wall/table mounted supply box made out of 2 mm thick CRCA Sheet for Emergency Escape facility rooms I & II (Second Floor right side of Technical Hanger) comprising of 1. 16A,DP, MCB, 10 KA along with 15Ax 1No. Plug & Socket. 2. 16A,DP, MCB, 10 KA along with 16A, 3 Pin Industrial Type Male-Female connector. Switchgear/MCB in panel : Havells/ L&T/Seimens. Make of meter & panel : AE/Protech Services/Merlin Hawk

6

-

-

... More
Supply & Fixing of wall/Table mounted supply box made out of 2 mm thick CRCA Sheet for ZHUK-ME Test Restoration LCS work station 1. 50A, TPN, MCB, 10 KA with 63A, 5 Pin Industrial Type Male-Female connector 2. 32A, DP MCB, 10 KA with 32A, 3 Pin Industrial Type Male-Female Connector. Switchgear/MCB in panel : Havells/ L&T/Seimens. Make of meter & panel : AE/Protech Services/Merlin Hawk

1

-

-

... More
Supply & fixing of wall /Table mounted supply box made out of 2 mm thick CRCA Sheet for ZHUK-ME Test Restoration ERP-2, Work Station 1. 40A, TPN, MCB, 10 KA with 63A, 5 Pin Industrial Type Male-Female Connector. 2. 40A DP, MCB, 10 KA with industrial type 3 Pin, Male-Female connector 3. 32A DP, 10 KA with 10Ax3 No's Socket. Switchgear/MCB in panel : Havells/ L&T/Seimens. Make of meter & panel : AE/Protech Services/Merlin Hawk

1

-

-

... More
Supply & Fixing of wall/Table mounted supply box made out of 2 mm thick CRCA Sheet for ZHUK-ME Test restoration Comprising of : 1. 32A, DP, MCB, 10 KA, alongwith 5A x 5 No. & 15A x 5 No. Sockets. 2. 32A TPN MCB, 10 KA alongwith 16A, 5 Pin Industrial Type Male Female Sockets- 2 No.s and 5A Sockets, 2 No's 3. 10A DP, MCB, 10KA alongwith 5A x 2 No. Sockets. Switchgear/MCB in panel : Havells/ L&T/Seimens. Make of meter & panel : AE/Protech Services/Merlin Hawk

5

-

-

... More
Supply & fixing of wall/table mounted supply box made out of 2 mm thick CRCA Sheet for ZHUK-ME Test Restaration MPR 1&5 Work Station Comprising of 1. 32A, DP, MCB, 10 KA, alongwith 5A x 5 No. & 15A, x 5 No.Sockets. 2. 26A, TPN, MCB, 10 KA alongwith 32A, 5 Pin Industrial Type Male Female Connector. 3. 10A, DP, MCB, 10 KA alongwith 5A x 2 No. Sockets. Switchgear/MCB in panel : Havells/ L&T/Seimens. Make of meter & panel : AE/Protech Services/Merlin Hawk

2

-

-

... More
Supply & Fixing of wall/Table mounted supply box made out of 2 mm thick CRCA Sheet for ZHUK-ME Test Restration MPR 2 & 4 Work Station comprising of: 1. 32A, DP, MCB, 10KA alongwith 5A x 5 No. & 15A x 5 No. Sockets. 2. 10A, DP, MCB, 10KA alongwith 5A x 2 No. Sockets. Switchgear/MCB in panel : Havells/ L&T/Seimens. Make of meter & panel : AE/Protech Services/Merlin Hawk

2

-

-

... More
Supply & fixing of wall mounted mains distribution panel made out of 2 mm thick CRCA Sheet with V & F digital meters Comprising of Incoming Side 100A, 4 P, MCCB, 25KA, alongwith Copper bus bar mounted on insulators suitable for 415V, 3 Ph,4 wire, 50 Hz, 150A. Outgoing side 1. 16A,TPN, MCB, 10 KA (for 8 kVA/115V SFC) 2. 10A, DP, MCB, 10 KA (for 1 kVA/36V, 1 Ph. SFC) 3. 32A, TPN, MCB, 10 KA (for 27VDC) 4. 40A, TPN, MCB, 10 KA (for 20 kVA Stab). Switchgear/MCB in panel : Havells/ L&T/Seimens. Make of meter & panel : AE/Protech Services/Merlin Hawk

1

-

-

... More
Supply & fix wall mounted output distribution Panel made out of 2 mm thick CRCA Sheet with V & F meters for all outputs Comprising of 1. 80A, DP, MCB, 10 KA alongwith copper bus bar mounted on insulators suitable for 100A, 115V, 1 Ph, 2 wire, 400 Hz, 1 ft long. 2. 32A, DP, MCB, 10KA, alongwith copper bus bar mounted on insulators suitable for 32A, 36, V, 2 wire 50 Hz, 1 ft. long. 3. 200A, 4 P, MCCB, 25KA alongwith copper bus bar mounted on insulators suitable for 400A, 27V, 2 wire, DC, 1 ft. Long. 4. 32A, TPN, MCB, 10KA alongwith Copper bus bar mounted on insulators suitable for 40A, 415V, 4 wire, 3 Ph, 50 Hz, 1 ft long . Switchgear/MCB in panel : Havells/ L&T/Seimens. Make of meter & panel : AE/Protech Services/Merlin Hawk

1

-

-

... More
Supply & Fix wall mounted table supply box made out of 2 mm thick CRCA Sheet comprising of 1. 40A, DP, MCB, 10 KA alongwith 16A, 3 Pin Industrial tpe Male Female Connector, 2x15A, Sockets & 2x5A Sockets. 2.40A, DP, MCB, 10 KA alongwith 16A, 3 Pin Industrial Type Male-Female Connector 3. 40A, DP,MCB, 10 KA alongwith 32A, 3 Pin Industrial Type male-Female connector. Switchgear/MCB in panel : Havells/ L&T/Seimens. Make of meter & panel : AE/Protech Services/Merlin Hawk

15

-

-

... More
Supply & fixing of wall mounted mains distribution panel Indoor type made out of 2 mm thick CRCA Sheet with V & F digital meters comprising of. Incoming side : 160A, MCCB, 4 P, 25KA, alongwith copper bus bar mounted on insulators suitable for 415V AC, 4 wire 3 Ph, 50 Hz. 200A, 1 ft. long. Outgoing side : 1. 42A, TPN, MCB, 10 KA (for 115V SFC) 2. 6A, TPN, MCB, 10 KA (for 36V/3Ph SFC) 3. 16A, TPN, MCB, 10 KA (for 36/1Ph SFC) 4. 63A, TPN, MCB, 10 KA (for 27DVC) 5. 42A, TPN, MCB, 10 KA (for 220V Stab.) 6. 10A, DP, MCB, 10 KA (for 36/1Ph,400 Hz, SFC) Switchgear/MCB in panel : Havells/ L&T/Seimens. Make of meter & panel : AE/Protech Services/Merlin Hawk

1

-

-

... More
Supply & fix wall mounted output distribution panel, indoor type made out of 2mm thick CRCA sheet with V & F digital meters for all outputs Comprising of : 1. 125A, MCCB, 4P, 25KA alongwith Copper bus bar mounted on insulators suitable for 115V, 1 Ph, 2 wire, 400 Hz, 250A, 8"long. 2. 32A, TPN, MCB, 10 KA alongwith Copper bus bar mounted on insulators suitable for 36V, 3 Ph, 4 wire, 400 Hz, 40A, 8" long. 3. 100A, MCCB, 4P, 25KA alongwith Copper bus bar mounted on insulators suitable for 26V, 1 Ph, 2 wire, 50 Hz 200A, 8" long. 4. 630A, MCCB, 4P, 35KA alongwith copper bus bar mounted on insulators suitable for 27V, 2 wire, DC, 1400A, 12" long. 5. 32A, TPN, MCB, 10 KA alongwith Copper bus bar Mounted an insulators suitable for 415V, 3 Ph, 4 wire, 50 Hz, 40A 8" long. 6. 26A, DP, MCB, 10KA alongwith copper bus bar mounted on insulators suitable for 36V, 1Ph,2 wire, 400 Hz, 30A, 8" long. Switchgear/MCB in panel : Havells/ L&T/Seimens. Make of meter & panel : AE/Protech Services/Merlin Hawk

1

-

-

... More
Supply & fixing of wall/table mounted supply box made out of CRCA sheet comprising of: 1. 6A, DP, MCB, 10 KA with 5A x 2 No. Sockets 2. 32A,DP,MCB, 10 KA with 32A, 3 Pin, industrial type male Female connectors 3. 32A, DP,MCB 10KA with 10A x 4 No's sockets. Switchgear/MCB in panel : Havells/ L&T/Seimens. Make of meter & panel : AE/Protech Services/Merlin Hawk

20

-

-

... More
Supply & fixing of wall/Table mounted supply box, indoor type comprising of: 1. 10A, DP, MCB, 10KA alongwith 5A, x 2 No. Sockets. 2. 6A,DP, MCB, 10KA alongwith 5A, Socket 3. 16A, D,P MCB, 10KA alongwith 15A, Socket. 4. 16A, DP, MCB, 10 KA alongwith Industrial type 16A, 3 Pin Male Female Connector.Switchgear/MCB in panel : Havells/ L&T/Seimens. Make of meter & panel : AE/Protech Services/Merlin Hawk

4

-

-

... More
Supply & fixing of wall/table mounted supply box, indoor type comprising of : 1. 10A, DP, MCB, 10 KA alongwith 5A x2No. Sockets. 2. 6A, DP, MCB, 10KA alongwith 5A Socket. 3. 32A, DP, MCB, 10KA alongwith Industrial Type 32A, 3 Pin Male Female Connector. Switchgear/MCB in panel : Havells/ L&T/Seimens. Make of meter & panel : AE/Protech Services/Merlin Hawk

2

-

-

... More
Supply & Fixing of wall/table mounted supply box indoor type comprising of : 1. 10A,DP, MCB, 10 KA alongwith 5A x 2 No. Sockets. 2. 6A,DP, MCB, 10 KA alongwith 5 A, Socket. 3. 32A,DP, MCB, 10 KA alongwith Industrial type 32A, 3 Pin Male Female connectors. Switchgear/MCB in panel : Havells/ L&T/Seimens. Make of meter & panel : AE/Protech Services/Merlin Hawk

2

-

-

... More
Supply & Fixing of wall/Table mounted supply box, indoor type 1. 10A, DP, MCB, 10KA alongwith 5A x 2 No. Sockets. 2. 6A, DP, MCB, 10 KA alongwith 5A Socket. 3. 16A,DP, MCB, 10KA alongwith Industrial type Male-Female 16A, 3 Pin Connector. 4. 16A,DP, MCB, 10KA alongwith 15A Socket. 5. 16A TPN, MCB, 10 KA alongwith 15A Socket. Switchgear/MCB in panel : Havells/ L&T/Seimens. Make of meter & panel : AE/Protech Services/Merlin Hawk

12

-

-

... More
Supply & fixing of panel made out of CRCA sheet comprising of: 1. Copper Bus Bar Mounted on insulators suitable for 27V DC, 2 wire, 250A, 6" Long. 2. Copper Bus Bar Mounted on insulators suitable for 208V, 3 Ph, 4 wire, 170 A, 50 Hz, 6 "long. 3. Copper bus bar mounted on insulators suitable for 150A, 220V, 1Ph, 2 wire, 50Hz, 6" long Switchgear/MCB in panel : Havells/ L&T/Seimens. Make of meter & panel : AE/Protech Services/Merlin Hawk

1

-

-

... More
Supply & fix panel made out of CRCA sheet comprising of: 1. Copper Bus Bar Mounted on insulators suitable for 27V DC, 2 wire, 60A, 6" Long. 2. Copper Bus Bar Mounted on insulators suitable for 36V, 1Ph, 2 wire, 60 A, 50 Hz, 6 "long. 3. Copper bus bar mounted on insulators suitable for 80A, 220V, 1Ph, 2 wire, 50Hz, 6" long Switchgear /MCB in panel : Havells/ L&T/Seimens. Make of meter & panel : AE/Protech Services/Merlin Hawk

2

-

-

... More
Supply & fixing of Bus bar Panel made out of 2mm thick CRCA Sheet indoor type for Second Floor, Left side, Technical hanger comprising of : 1.Copper bus Bar mounted on insulator suitable for 300A, 2 wire, 27VDC, 6" long. 2. Copper bus bar Mounted on insulator suitable for 60A, 2wire 115V, 400 Hz, 6" long. 3. Copper bus bar Mounted on insulator suitable for 100A, 2 wire, 220 V, 50 Hz 6" long. 4.Copper bus bar Mounted on insulater suitable for 30A, 4 wire, 3 Ph, 36V, 400 Hz 6" long. 5. Copper bus bar Mounted on insulator suitable for 120A, 2 wire, 1 Ph, 36V AC, 6" long. 6. Copper bus bar mounted on insulator suitable for 30A, 36V, 1Ph, 2 wire, 400Hz, 6" long. Switchgear/MCB in panel : Havells/ L&T/Seimens. Make of meter & panel : AE/Protech Services/Merlin Hawk

1

-

-

... More
Supply & fixing of Bus bar Panel made out of 2mm thick CRCA Sheet indoor type for Second Floor, Left side, Technical hanger comprising of : 1.Copper bus Bar mounted on insulator suitable for 300A, 2 wire, 27VDC, 6" long. 2. Copper bus bar Mounted on insulator suitable for 60A, 2wire 115V, 400 Hz, 6" long. 3. Copper bus bar Mounted on insulator suitable for 100A, 2 wire, 220 V, 50 Hz 6" long. 4. Copper bus bar Mounted on insulator suitable for 120A, 2 wire, 1 Ph, 36V AC, 6" long. Switchgear/MCB in panel : Havells/ L&T/Seimens. Make of meter & panel : AE/Protech Services/Merlin Hawk

2

-

-

... More
Supply, Install, testing and commissioning of Sinle Core flexible copper cable of size 2.5 Sq mm single core, flexibe, copper cable complete all as specified & directed. Make: Havells/Phinolex/polycab/shyam

58

-

-

... More
Supply, Install, testing and commissioning of Sinle Core flexible copper cable of size 4.0 Sq mm single core, flexibe, copper cable complete all as specified & directed. Make: Havells/Phinolex/polycab/shyam

78

-

-

... More
Supply, Install, testing and commissioning of Sinle Core flexible copper cable of size 6.0 Sq mm single core, flexibe, copper cable complete all as specified & directed. Make: Havells/Phinolex/polycab/shyam

90

-

-

... More
Supply, Install, testing and commissioning of Sinle Core flexible copper cable of size 10.0 Sq mm single core, flexibe, copper cable complete all as specified & directed. Make: Havells/Phinolex/polycab/shyam

130

-

-

... More
Supply, Install, testing and commissioning of Sinle Core flexible copper cable of size 16 Sq mm single core, flexibe, copper cable complete all as specified & directed. Make: Havells/Phinolex/polycab/shyam

170

-

-

... More
Supply, Install, testing and commissioning of Sinle Core flexible copper cable of size 25 Sq mm single core, flexibe, copper cable complete all as specified & directed. Make: Havells/Phinolex/polycab/shyam

290

-

-

... More
Supply, Install, testing and commissioning of Sinle Core flexible copper cable of size 35 Sq mm single core, flexibe, copper cable complete all as specified & directed. Make: Havells/Phinolex/polycab/shyam

380

-

-

... More
Supply, Install, testing and commissioning of Sinle Core flexible copper cable of size 50 Sq mm single core, flexibe, copper cable complete all as specified & directed. Make: Havells/Phinolex/polycab/shyam

520

-

-

... More
Supply, Install, testing and commissioning of Sinle Core flexible copper cable of size 70 Sq mm single core, flexibe, copper cable complete all as specified & directed. Make: Havells/Phinolex/polycab/shyam

710

-

-

... More
Supply, Install, testing and commissioning of Sinle Core flexible copper cable of size 95 Sq mm single core, flexibe, copper cable complete all as specified & directed. Make: Havells/Phinolex/polycab/shyam

890

-

-

... More
Supply, Install, testing and commissioning of Sinle Core flexible copper cable of size 120 Sq mm single core, flexibe, copper cable complete all as specified & directed. Make: Havells/Phinolex/polycab/shyam

1350

-

-

... More
Supply, Install, testing and commissioning of Sinle Core flexible copper cable of size 150 Sq mm single core, flexibe, copper cable complete all as specified & directed. Make: Havells/Phinolex/polycab/shyam

1750

-

-

... More
Supply, Install, testing and commissioning of Sinle Core flexible copper cable of size 185 Sq mm single core, flexibe, copper cable complete all as specified & directed. Make: Havells/Phinolex/polycab/shyam

2195

-

-

... More
Supply, Install, testing and commissioning of Sinle Core flexible copper cable of size 240 Sq mm single core, flexibe, copper cable complete all as specified & directed. Make: Havells/Phinolex/polycab/shyam

2475

-

-

... More
Supply, Install, testing and commissioning of Sinle Core flexible copper cable of size 300 Sq mm single core, flexibe, copper cable complete all as specified & directed. Make: Havells/Phinolex/polycab/shyam

3400

-

-

... More
Supply, Install, testing and commissioning of Sinle Core flexible copper cable of size 400 Sq mm single core, flexibe, copper cable complete all as specified & directed. Make: Havells/Phinolex/polycab/shyam

3900

-

-

... More
Supply & Fixing of PVC slotted cable trays of 100mm x 100mm to accommodate the cables as per site requirement including support, nuts, bolts,washer etc complete as directed.

500

-

-

... More
Supply & Fixing of PVC slotted cable trays of 75mm x 75mm to accommodate the cables as per site requirement including support, nuts, bolts,washer etc complete as directed.

700

-

-

... More
Supply, Install 240Sq.mm Single Core Rubberised, unarmoured flexible copper cable of (for Output of 40KW "O" Level & "I" Level, 2 strands of 35 metre each ) Make: Havells/Phinolex/polycab/shyam

140

-

-

... More
Supply, Installation & Fixing of 185 Sq. mm Single Core Rubberised, unarmoured flexible copper cable of (for Output of 90kVA "O" Level & "I" Level, 4 strands of 35 metre each) Make: Havells/Phinolex/polycab/shyam

280

-

-

... More
Supply, Install 25 Sq. mm Single Core Rubberised, unarmoured flexible copper cable of ( for Output of 45kVA ( 63A), Maintenance Hanger F1, F2, Technical Hanger & Hawk Hanger 4 strands of 30 mt. each x 4 outlets in each hanger x 4 Hangers ) Make: Havells/Phinolex/polycab/shyam

1920

-

-

... More
Supply, Installation & Fixing of 25 Sq. mm Single Core Rubberised, unarmoured flexible copper cable of ( for Output of 27V DC ( 30A), 2 strands of 30 mt. each x 2 outlets in each hanger x 4 Hangers ) Make: Havells/Phinolex/polycab/shyam

480

-

-

... More
Supply, Install 240 Sqmm Single Core Rubberised, unarmoured flexible copper cable of ( for Output of 27V DC ( 12KW) 2 strands of 30 metre each x 9 No. ) Make: Havells/Phinolex/polycab/shyam

540

-

-

... More
Supply & Fix NATO Connector for 27V DC complete all as speicified and directed.

19

-

-

... More
Supply & Fix NATO Connector for 208V, 3Ph, 400Hz complete all as speicified and directed.

18

-

-

... More
ACOUSTIC DESIGN

-

-

-

... More
S&F in position Acoustical wall panelling at upper reach above 5ft to all heights with eco friendly light weight calcium silicate fully perforated acoustical wall panels/ tiles of size 595mm x 595mm fixed to 50mm width vertical stud framing, eco friendly light weight calcium silicate wall panels/tiles shall be made of non-cementitious hydrated wet moulded calcium silicate slurry, reinforced with fibers and natural fillers, Free from formaldehyde and other harmful materials, does not contain any toxic ingredients, wall panels/ tiles shall be GRIHA accredited product suitable for green building applications complete all as speicified and directed.

3010.39

-

-

... More
Supply and Install Modular fluted acoustic wall panel using Wooden Perforated Slats made of pine/Eucalyptus wood core E1 grade fiberboard with melamine/ veneer/ laminated finish, the surface is maintained for Acoustics by groove perforated slats pattern L16-3/L23-3/L32-3 - (3mm grooves @16/23/32mm pitch with 27% open area), the edges of the panels shall be “tongue-and-grooved” to receive special clips for installation. the back of the perforated panel shall have Sound absorbing non-woven acoustical fleece of 0.27 mm thick, surface density 64g/m2, the panels shall be mounted on special Aluminium keel cross channel using clips, tongue-groove edge for a seamless look, Fire retardant grade, size 128/192 x2440x16mm, volume density of base board 700Kg/m3, weight 9Kg/m2 installed by using Sal wood framework system.Sal wood framework system shall be done by using wooden battens of size 30x50mm and length of 3000mm is fastened to the wall positioned both sides horizontally & vertically at every 600mm centre to centre. SynthPF 30mm thickness 1000GSM to be filled in side the Sal wood framing for acoustical support. Aluminium core cross channel CC18, thickness 0.5mm, length 2400mm, web 15mm & 27mm, depth 18mm and flanges of 7mm with suitable edge & center brackets is then fixed perpendicular to the Sal wood frame with the help of fasteners at every 400mm centers/as preferred by the manufacturer. Perforated Wooden SLATS of customized colour as per architect/Engineer choice (128/192) x 2440x16mm to be then fixed perpendicular to Aluminium cross channel CC18 with suitable edge & centre brackets. Contractor to provide expansion joints gap of 3mm at every 4.88m length wise and 4.992m width wise.

6184.49

-

-

... More
Technical Parameters • Fire (Class) - 1 & P • Acoustics NRC =0.75 •Climate (°C, RH) - 50, 70 • Light reflectance (%) - Color Based • Green (VOC, RC %) - El, 25 Note: Wooden perforated SLATS panels will be customized as per design intent & Shop drawing needs to be submitted based on concept design intent before execution of work

-

-

-

... More
S&F eco-friendly light weight calcium silicate acoustical false ceiling tiles in module size of 600x600mm G.I. powder coated 24mm T grid system, eco friendly light weight calcium silicate tiles shall be made of non-cementitious hydrated wet molded calcium silicate slurry, reinforced with fibers and natural fillers, free from formaldehyde and other harmful materials, does not contain any toxic ingredients, tiles shall be GRIHA accredited product suitable for green building applications complete all as specified and as directed.

3248.85

-

-

... More
S&F Acoustic Doors Acoustic Door Timber Frame: The door frame profile is 125X150mm of TRIPLE REBATE, rebated shall be constructed out of treated “Engineered Hardwood/ Teakwood”, the frame shall be provided with acoustical seal ‘Lorient’ brand Batwing 1212 (LAS-1212) on vertical and top sides. The frame shall be provided with (Lorient LP 1004) fire and smoke intumescent seal of size 10 x 4 mm - 2 Nos. The frame shall be fixed to the wall made up of AAC block/RCC with adequate numbers of counter sunk M10x140 Gl "anchor fasteners of approved Make on each vertical side on top horizontal member. The frames are provided with a label indicating the Sound Transmission Classification rating (STC). The Door frame shall be finished with Polish / Paint/ Wrapping of Laminate or Veneer or Unfinished to match with door shutter, as per Client's requirement complete all as specified and as directed.

384.96

-

-

... More
S&F Sliding window make Salamander window system GmbH - Germany, 3 track - 2 Glass and 1 mesh with DGU glass and EPDM gasket sealing 6 mm toughened glass + 10 mm air gap with Argon gas + 5 mm toughened glass total 21 mm DGU Glass and STC of 30 dB, Polyvinyl Chloride un plasticized (PVC-U) white colour, Type of opening Sliding; Opening direction Sash left before sash right with all related window accessories, with Operating forces according to EN 13115:2001-07 Class: 1, Air permeability according to EN 12207:2016-12 Class - 4, Resistance to wind load according to EN 12210:2016-03 Class: C1/B3 and Water tightness according to EN 12208:1999-11 Class: 7A complete all as specified and as directed.

454.8

-

-

... More
INTERNAL ELECTRIFICATION

-

-

-

... More
M&L earthing complete with galvanised steel earth plate electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of Plate not less than 1.50 m below normal ground level connected to GI earth lead wire 4.0 mm dia [earth lead] and GI pipe 15 mm, light grade for earthing lead protection to the extent of maximum 7.5m, earth plate electrode surrounded by 150 mm thick packed layers of charcoal and common salt filled in alternate layers, connected to the plate by means of GI Bolts & Nuts complete all as per electrical plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, charcoal, common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. complete all as specified. Note: GI earth wire upto 7.5 metres shall be deemed to be included in the quoted lumpsum and beyond 7.5 metre shall be measured and paid separately

128

-

-

... More
Point wiring with two runs of 1.5 Sq.mm. FRLS PVC insulated unsheathed copper conductor multi stranded 1100 Volts grade, ISI marking drawn through and including non metallic PVC rigid concealed conduit and conduit accessories medium grade, ISI marked, including modular metal flush box with and including modular white cover plate with frame for mounting modular switches/sockets/fan regulators etc. including one run of 1.5 Sq.mm. PVC insulated unsheathed copper cable for earth continuity, connected to earth dolly, for One light/bell point controlled by one no. one way switch or One fan (ceiling fan/exhaust fan/wall mounted) point controlled by one switch or one 3 pin socket outlet 5 Amps on independent board on independent board complete all as specified and as directed.

3

-

-

... More
All as per Sl Item No.128 here-in-before but for one 3 pin socket outlet 15 Amps on independent board with two runs of 4 Sq.mm. FRLS PVC wire and one run of 4 Sq.mm. copper cable for earth continuity.

13

-

-

... More
Point Wiring complete with 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, confirming to IS - 694 drawn through and including heavy duty PVC Conduit, 20 mm dia including all accessories concealed in Walls / Roofs / Floors / Ceiling etc. and Pressed Metal Flush Box made out of 2mm thick MS Sheet of suitable size and 3 mm thick Hylam Sheet top cover for fixing switches, fittings, regulators etc concealed in walls, including 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable as earth continuity conductor with colour coding and connecting to Earth Dolly for One Light / Fan Point / Bell Point controlled by One Switch complete all as specified.

3454

-

-

... More
All as per Serial Item No. 430 above but One 3 Pin Switch Socket Outlet 5 Amps on Independent Board complete all as specified.

90

-

-

... More
All as per Serial Item No. 430 above but one 3 Pin Switch Socket Outlet 16 Amps on independent board, with 1100 Volts, FRLS grade, 2.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable confirming to IS - 694 and including 1100 Volts, FRLS grade, 2.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable as Earth Continuity Conductor.

286

-

-

... More
All as per Serial Item No. 430 above but one 3 Pin Switch Socket Outlet 16 Amps on independent board, with 1100 Volts, FRLS grade, 4.0 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable confirming to IS - 694 and including 1100 Volts, FRLS grade, 4.0 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable as Earth Continuity Conductor.

291

-

-

... More
Sub main wiring with 2 runs of single core 1.5 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawing through and including heavy duty PVC Conduit, 20 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. including One run of 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor complete all as specified. [Note: 3 runs of 1.5 Sq.mm & one run of 20mm dia PVC Conduit will be measured as one unit]

30

-

-

... More
Sub main wiring with 2 runs of single core 2.5 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawing through and including heavy duty PVC Conduit, 20 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. including One run of 2.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor complete all as specified. [Note: 3 runs of 2.5 Sq.mm & one run of 20mm dia PVC Conduit will be measured as one unit]

4570

-

-

... More
Sub main wiring with 2 runs of single core 4.0 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawing through and including heavy duty PVC Conduit, 20 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. including One run of 4.0 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor complete all as specified. [Note: 3 runs of 4.0 Sq.mm & one run of 20mm dia PVC Conduit will be measured as one unit]

1150

-

-

... More
Sub main wiring with 2 runs of single core 6.0 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawing through and including heavy duty PVC Conduit, 20 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. including One run of 6.0 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor complete all as specified. [Note: 3 runs of 6.0 Sq.mm & one run of 20mm dia PVC Conduit will be measured as one unit]

1030

-

-

... More
S&F energy efficient LED tube light fitting [mirror optic] with tube 2x20 watts, 240 Volts, 50 Hz, luminous efficiency 100 Lumen per Watt, CRI80, PF0.9, surface mounted, decorative ultra slim square profile LED lighting fixture etc., with extruded polycorbonate environmental friendly, energy efficient ready to use pack complete with mounting bracket etc., including connecting up with 1.0 Sq.mm, 3 core flexible copper conductor complete all as specified and as directed.

746

-

-

... More
S&F energy efficient LED tube light fitting [mirror optic] with tube 20 watts, 240 Volts, 50 Hz, luminous efficiency 100 Lumen per Watt, CRI80, PF0.9, surface mounted, decorative ultra slim square profile LED lighting fixture etc., with extruded polycorbonate environmental friendly, energy efficient ready to use pack complete with mounting bracket etc., including connecting up with 1.0 Sq.mm, 3 core flexible copper conductor complete all as specified and as directed.

738

-

-

... More
S&Fing of ceiling fan complete with blades, down rod and other accessories, AC 230 Volts, 1200 mm sweep, min air delivary 210 CFM with service value 6.00, BEE, 5 star rated with brushless direct current motor [BLDC] including connecting with 1.0 Sqmm, 2 core copper conductor from ceiling rose complete all as specified and as directed.

387

-

-

... More
S&Fing exhaust fan, 300 mm sweep, made out of sturdy engineering plastic, 1200 RPM heavy duty with louvers, AC single phase, 230 volts , connection with 1.0 sqmm twin core copper conductor flexible wire from ceiling rose including making necessary opening and making good the disturbed surface complete all as specified and as directed.

116

-

-

... More
S&F telephone socket [JACK TYPE] RJ 11 with modular cover plate complete with all accessories complete all as specified and directed.

112

-

-

... More
S&F internet socket [JACK TYPE] RJ 45 with modular cover plate complete with all accessories complete all as specified and directed.

112

-

-

... More
S&F 30 W LED flame proof well glass fitting in die cast alu housing with heat resistant toughned glass, made of aluminium alloy, LMG, CIMFR certified, recommended for gas/ vapour group of IIM & IIB and Zone 1 & 2 IP 65 protected complete with all accessories prewired including connecting up with twin core twisted flexible copper conductor of suitable size complete all as specified and as directed.

90

-

-

... More
S&F energy efficient LED Porch light fitting with 24 Watt LED down light including all holding mechanism in floor/ wall, 240 Volts, 50 Hz, luminous efficiency 100 Lumen per Watt, CRI80, PF0.9, surface mounted, decorative ultra slim square profile LED lighting fixture etc., with extruded polycorbonate environmental friendly, energy efficient ready to use pack complete with mounting bracket etc., including connecting up with 1.0 Sq.mm, 3 core flexible copper conductor complete all as specified and as directed.

16

-

-

... More
S&F building security light fitting 36 Watt , luminous efficiency 100 Lumen per Watt, CRI80, PF0.9, new generatiion energy saving & environmental friendly long life, made up of pressure die cast aluminium housing with high efficient LED as lighting source and PC cover having top opening separate driver compartment with IP66 protection pre-wired and connecting up with with 1.0 Sqmm copper conductor cable upto connector including 1.5 metre long GI tubing light grade bracket of 32 mm dia bend to shape for fixing on wall/ pole with suitable MS bracket nuts, bolts etc., complete all as specified and directed.

54

-

-

... More
S&F energy efficient LED suspended light fitting [high bay light] with 90 Watt LED including all holding mechanism, 240 Volts, 50 Hz, luminous efficiency 120 Lumen per Watt, CRI80, PF0.9, surface mounted, IP 54 decorative ultra slim square profile LED lighting fixture etc., complete with mounting bracket etc., including connecting up with 1.5 Sq.mm, 3 core flexible copper conductor complete all as specified and as directed.

87

-

-

... More
S&F energy efficient LED suspended light fitting [mirror optic] with 210 watts, pendant, LED light including all holding mechanism in floor/ wall, 240 Volts, 50 Hz, luminous efficiency 100 Lumen per Watt, CRI80, PF0.9, surface mounted, decorative ultra slim square profile LED lighting fixture etc., with extruded polycorbonate environmental friendly, energy efficient ready to use pack complete with mounting bracket etc., including connecting up with 1.0 Sq.mm, 3 core flexible copper conductor complete all as specified and as directed.

92

-

-

... More
S&F energy efficient LED recess mount light fitting 10 watts, LED down light including all holding mechanism in floor/ wall, 240 Volts, 50 Hz, luminous efficiency 100 Lumen per Watt, CRI80, PF0.9, surface mounted, decorative ultra slim square profile LED lighting fixture etc., with extruded polycorbonate environmental friendly, energy efficient ready to use pack complete with mounting bracket etc., including connecting up with 1.0 Sq.mm, 3 core flexible copper conductor complete all as specified and as directed.

391

-

-

... More
S&F energy efficient LED recess mount light fitting 10 watts, LED mirror light including all holding mechanism in floor/ wall, 240 Volts, 50 Hz, luminous efficiency 100 Lumen per Watt, CRI80, PF0.9, surface mounted, decorative ultra slim square profile LED lighting fixture etc., with extruded polycorbonate environmental friendly, energy efficient ready to use pack complete with mounting bracket etc., including connecting up with 1.0 Sq.mm, 3 core flexible copper conductor complete all as specified and as directed.

91

-

-

... More
S&F energy efficient LED recess mount light fitting 20 watts, LED down light including all holding mechanism in floor/ wall, 240 Volts, 50 Hz, luminous efficiency 100 Lumen per Watt, CRI80, PF0.9, surface mounted, decorative ultra slim square profile LED lighting fixture etc., with extruded polycorbonate environmental friendly, energy efficient ready to use pack complete with mounting bracket etc., including connecting up with 1.0 Sq.mm, 3 core flexible copper conductor complete all as specified and as directed.

825

-

-

... More
S&F energy efficient LED recess mount light fitting 20 watts, LED down light including all holding mechanism in floor/ wall, 240 Volts, 50 Hz, luminous efficiency 100 Lumen per Watt, CRI80, PF0.9, surface mounted, decorative ultra slim square profile LED lighting fixture etc., with extruded polycorbonate environmental friendly, energy efficient ready to use pack complete with mounting bracket etc., including connecting up with 1.0 Sq.mm, 3 core flexible copper conductor complete all as specified and as directed.

825

-

-

... More
S&F MCB DB, double door, SPN, 12 way, sheet steel, with 200 Amps rated bus bar, 240 Volts, 50 Hz, IP : 43 protection,concealed in walls, complete all as specified and as directed.

49

-

-

... More
S&F MCB DB, double door, SPN, 8 way, sheet steel, with 200 Amps rated bus bar, 240 Volts, 50 Hz, IP : 43 protection,concealed in walls, complete all as specified and as directed.

52

-

-

... More
S&F MCB DB, double door, SPN, 4 way, sheet steel, 415 Volts, 50 Hz, IP : 43 protection, including provision for fixing MCCB 4 Pole as incomer and outgoing circuit MCB SP/TP complete fill empty way with blanking plates complete all as specified and as directed.

3

-

-

... More
S&F MCB DB, double door, TPN, 4 way, sheet steel, 415 Volts, 50 Hz, IP : 43 protection, including provision for fixing MCB 4 Pole as incomer and outgoing circuit MCB SP/TP complete fill empty way with blanking plates complete all as specified and as directed.

48

-

-

... More
S&F MCCB DB, double door, VTPN, 4 way, sheet steel, 415 Volts, 50 Hz, IP : 43 protection, including provision for fixing MCCB 4 Pole as incomer and outgoing circuit MCB SP/TP complete fill empty way with blanking plates complete all as specified and as directed.

15

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.