Military Engineer Services Tender

To know what Andhra Pradesh government has posted about any AP etender, Bidassist helps us to get a one-stop platform where a registered bidder can have access to the details on each and every eprocurement tender. There is no need to provide the details on the AP E-procurement website i.e. https://www.apeprocurement.gov.in as BidAssist helps us find the specific etender we're looking for. BidAassist has collated each and every Eproc Andhra Pradesh Tender on its website.

Military Engineer Services - MES Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date4 Dec 2024
Closing Date1 Jan 2025
Tender Amount₹ 5,07,05,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Get the Best Price For TMT
Starting from
₹51,000/MT*
Andhra Pradesh

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
M&L for light shade vitrified ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over 15mm thick cement mortor (1:6) screed bed complete all as specified and directed.

1500

-

-

... More
M&L for coloured non skid ceramic tiles 10 mm thick (square or rectangular) of area exc 0.18 but not exc 0.38 Sq.m in floor set and jointed in neat cement slurry and pointed in coloured cement to match laid over and including cement screed 15mm thick in CM 1:6 all as specified and directed.

150

-

-

... More
M & L for coloured glazed ceramic tiles 350 x 250 x 7 mm /450 x 300 x 7/8 mm thick in dado set and jointed in neat cement slurry and pointed in coloured cement to match fixed over incl rendering in CM 1:4, 10mm thick all as specified and directed.

50

-

-

... More
M&L for 20mm thick granite (of any Type ) work (table rubbed and polished) As in flooring skirting, in jambs, pillars, window cillos, cooking platforms and like including 15mm thick cement screed in CM 1:4 including pointing in white cement (1:2) using marble dust with admixture of pigment to matxh with the shade of granite complete all as specified and directed.

600

-

-

... More
M&L for 4mm thick PVC tiles laminated plain coloured, homogeneous, laid with approved rubber based adhesive in floors complete all as specfied and directed

162

-

-

... More
Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc laid in any mortar and rubbish off the MD land complete all as s[pecfied and directed

89

-

-

... More
M&L for Marble work 18 to 20mm thick (table rubbed and polished) in steps, jambs, pillars, windowcills,cooking platforms and like ixed over incl rendering in CM 1:4, 15mm thick all as specified and directed. including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade of Makrana doogri complete all as specfied and directed

290

-

-

... More
Demoliton brick work or stone masonry built in cement mortar including all quoins, arches , pillars etc and removing the debries to a distance 5km away from the Dockyard premises all as specified and directed.

28

-

-

... More
M&L for pre cast cement concrete type 1:3:6 type C-1 (20mm graded stone aggregate) block masonry with solid blocks exc 10 cm in width and setting in cement mortar 1:4 complete all as specified and directed.

28

-

-

... More
Taking down cement plaster on walls/Ceiling etc including racking out joints hacking for key scrubbing down with water and removing the debries away from the Dockyard premises all as specified and directed.

7480.9

-

-

... More
M&Lf or rendering 10 mm thick in CM (1:6) on fair faces of brick work or concrete surfaces and finishing the surface even and smooth with out using extra cement all as specified and dircted. Note :- The work shall be executed at a height 8 to 15mtr and the contractor has to provide scaffolding etc wherever necessary. The unit rate quoted shall be deemed to included for the same.

1319.22

-

-

... More
M&L for rendering 15 mm thick in CM (1:4) on fair faces of brick work or concrete surfaces and finishing the surface even and smooth with out using extra cement all as specified and directed.

4842.6

-

-

... More
M&L for rendering 10mm thick cement plaster 1:3 on fair faces of brick work or concrete surfaces of ceilings finished even & smooth(without using extra cement) all as specified and directed.

1319.22

-

-

... More
Supply only integral water proofing compound all as specified and directed.

120

-

-

... More
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets all as specified and directed.

696

-

-

... More
S&F anodised aluminium snap grid frame work of size 605x605mm using main and cross tee of size 15mm x 15mm 1.5mm ( weight not less than 0.12 kg / Rm) and wall angle of size 40mm x 25mm x 2mm ( weight not less than 0.36 kg / Rm) and 25 mm thick Perforated particle board/tiles for insula-tion and accoustic purposes, 60x60 cm in size, fixed with scrwes or with staples on snap grid complete in ceiling with screws to aluminum frame work in ceilings with hanger 6mm dia GI (up to 1200mm length) adjusting level fixed to roof slab by means of ceilng cleats made out of GI flat 40x 3mm size 60mm long and expansion hold fastners 12.5mm dia 40mm long complete , including cover fillets and all as specified and directed.

216

-

-

... More
S&F in repair Second class hard-wood Wrought in scantlings framed and fixed to walls complete all as specfied and directed

0.75

-

-

... More
S&F 25 mm thick Perforated particle board/tiles for insulation and accoustic purposes, 60x60 cm in size, fixed with scrwes to timber frame work or with staples on snap grid complete all as specfied and directed

480

-

-

... More
Taking down chowkats or frames exc 1.5 Sqm but not exc 4 Sqm each (Without taking off shutters from the frame) all as specified and directed.

40

-

-

... More
All as per item No.1.21 above, but not exc 1.5 Sqm each

26

-

-

... More
Supply and fix 2nd class hard wood plain, solid, straight chowkats and frames, wrought, framed on the solid rounded or chamfered, put together with glue pinned at joints all as specified and directed.

1

-

-

... More
S&F 2nd class hard wood 40mm thick plain, framed panelled shuttters ( any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium, density, wood particle board with commercial face veneers all as specified and directed.

32

-

-

... More
S&F for factory made second class hard wood 35mm thick plain framed paelled shutters (two panelled ) with lock rails and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneerign o both faces The size of rail and stile as per IS:1003 (Part I) Kiln seasoend and chemically pressure treated all as specified and directed

16

-

-

... More
Forming jambs etc., to opening in brick masonry, including cutting, toothing and properly bonding into old work, also facing, jointing and pointing to match existing work complete new work, built in cement mortar 1:6 all as specified and directed.

36

-

-

... More
M&L for PCC 1:3:6 type C1 usig 20mm graded crushed aggregates as in anchoring hold fast bed plates etc complete all as specified and directed

0.5

-

-

... More
S&F 100mm SS butt hinges, medium weight, cold rolled and fixed to wooden or steel framed all as specified and directed.

144

-

-

... More
S&F 200mm aluminium anodized barrel tower bolt of extruded section all as specified and direced.

96

-

-

... More
S&F 125mm aluminium anodized handles, cast type all as specified and direced.

96

-

-

... More
S&F 250mm aluminium alloy, anodized, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruced sections or cast aluminium alloy all as specified and directed.

48

-

-

... More
S&F Powder coated alluminuim doors , windows, ventilators with one or more rebated including joining cleat for fixing etc complete all as specified and as directed

2500

-

-

... More
S&F sheet glass of 5.5 mm thick , ordinry quality and glazing with oil putty in square exc .5 sqm in each pane all as specified and directed.

55

-

-

... More
S&F solar sun control film 25 Micron reflective type sticked to glass panes as per instructions of manufactures all as specified and directed.

55

-

-

... More
M&L for 12mm thick prelaminated particle board interior grade prelaminated both side with decorative choice lamination fixed with screws to aluminium frame work including allumnium powder coated beading all as specified and directed.

285

-

-

... More
S&F 150mm long floor door stopper of alluminium alloy body and toungue powder coated with hard drwn steel spring fixed all as specified and directed.

55

-

-

... More
S&F double action floor spring hydraulically regulated made up of minimum 1.25mm thick alluminium alloy sheet foundation box , main body stainless steel cover , governing pivot made of brass , other parts made of brass, other parts made of mild steel heavy duty and fixed all as specified and directed.

20

-

-

... More
S&F Aluminum 4 levers mortice lock ,Verticle type size 100mm all as specified and directed.

55

-

-

... More
Providing and fixing factory made uPVC white colour sliding window exceeding 2.00 Sqm .Three tack made of extruded profiles with wall thickness of 2.3mm (+ -0.2mm). Window profile with hollow section with multi chamber. Frame (88mmx52mm), sliding sash (42mmx67mm). Sliding mesh sash (42mmx57mm) sliding interlock (One vertical length in each shutters) (45.5mmx28mm, Glzing bead (24.5mmx16mm) will be mitred cut and fusionwelded at all corners, including drilling of holes for fixing hardware and drainage of water etc. making arrangement for fixing of hardware. EPDM gasket, 1.2+, -0.2mm thick galvanised steel frame (30mmx18mm) 2 Nos, sliding sash (30mmx18mm), sliding mesh sash(26mmx10mm) profile to be inserted in required profile,frame will be fixed to the wall with 8 mmx100mm long fasteners, Hardware (touch lock of zinc alloyed (white powder coated), steel roller system. Stainlesssteel wire cloth 0.36mm nominal dia of wire and average width of aprature 1.40mm and required accessories. Note :- (i) The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net opening will be measured for payment purpose). (ii) The rate quoted by the contractor inclusive off glass and wire mesh

21

-

-

... More
All as per item No.1.39 above but not exc 2.00 Sqm each

41

-

-

... More
S&F venetion roller blinds type 100mm wide including hanging arrangements madeup of anodised alluminium channel with acrylic mechanism with bottom weight type vista leveller all as per manufcturers instructions and as directed by Engr -In-Charge including takingdown th Wornout venetion blinds complete all as specified.

63

-

-

... More
S&F in repair 600 x 450mm bevelled edge mirror of selected quality glass mounted on 6mm thick AC building Boards commercial plywood and fixed to wooded plugs with chromium plated brass screws and cup washers complete all as specified and directed.

15

-

-

... More
Demolition of textile covering and including all padding concrete over RCC slab over roof, including removal of waste material away from Dockyard premises complete all as specified and directed.

2200

-

-

... More
M&L for providing, cement concrete type B1 1:2:4 (Using 20mm graded stone aggregate) as in roof padding concrete and kerbs or mud stops, rounded or chamfered on edges complete all as specified and directed.

88

-

-

... More
M&L for 10mm thick scred bed over padding concrete cement mortar 1:4 with water proofing compound as per manufacture instructions by weight of cement and finish the surface even and smooth with out using extra cement complete all as specified and directed. Note :- Supply WPC will be measured and paid separately.

2200

-

-

... More
M&L for applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.20 kg per Sqm including cleaning of surfaces all as specified and directed.

2200

-

-

... More
M&L for APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) shall be laid over entire roof surface and on vertical surface up to groves with other laps of 100mm. The over lap shall be sealed by flames complete all as specified and directed.

2200

-

-

... More
M&L for bitumastic gola filling in crumple joints , with 80/25 buitmen and coarse sand mixture 1:3 by weight 8cm x 8cm at junction of roofing to vertcal surfaces complete all as specified and directed.

60

-

-

... More
Demolition of cement concrete of any description and in any position and removing the material away from dockyard premises complete all as specified and directed.

7

-

-

... More
M&L for precast RCC 1:2:4 type B1 using 20 mm graded stone aggregate as in cover slabs set in CM 1;6 complete all as specified and directed.

4

-

-

... More
M&L for mild TMT bars 10mm dia and over cut to length, bent to shape required including binding with and incl mild steel wire (annealed) not less than 0.90mm dia complete all as specified and directed.

1480

-

-

... More
M&L for mild steel (deformed bars) 6 to 8mm dia and over cut to length bent to shape and binding with and incl mild steel wire (annealed) not less than 0.90mm dia complete all as specified and directed.

815

-

-

... More
Demolition of cement concrete in ground floor and paving not exc 15cm thickness (Below or above ground level) including removal of debris from the Dockyard permises all as specified and directed.

72

-

-

... More
M&L for PCC 1:4:8 type D2 using 40mm graded stone aggregate 100mm thick as in sub base for floors, hard standings etc complete all as specified and directed.

264

-

-

... More
M&L for PCC 1:2:4 type B2, using 40mm graded stone aggregate 100mm thick as in floor and finishing the top surface even and smooth without using extra cement and spike rolling to surface or making impression of expanded metals whilst concrete green complete all as specified and directed.

264

-

-

... More
M&L for 75mm thick in cement concrete type C2 1:3:6 (Using 40mm graded stone aggregate) as in plinth protection finished even and smooth with out using extra cement complete all as specified.

265

-

-

... More
M&L forming construction joints 30mm deep and 10mm wide, filled with sealing compound grade 'A' complete all as specified and directed.

4

-

-

... More
Chipping and removing of spalled concrete,craked,porous/Micro concrete above 25mmto 100mm: Chipping and removing of spalled concrete,craked,porous/Micro concrete andweekconcrete ,at allheigths and depths,upto a depth of 25mm behind thereinforcement rods or depth of cabonation whichever is deeper andcleaning of the reinforcement barsand exposed concrete to remove scale by chipping,wire brushing ,emery sheets etc to enable the mesurement of the reduced dia of the bars, application of zinc primer to the bars on all sides of the reinforcement and application opfepoxy bonding agent to exposedold concrete surfaces. Leaddistanceshall be 50m from ground level to unloading location. This also includes the chipping and removal of gunning work carried out recently to check the reinforcement in order to decide on the requirement and addition of reinforcement . Payment towards application of zinc primer and epoxy bonding agent shall be paid in respective items rate of the contract. Scope including menpower, machinery, tools and consumables etc , to complete the job as per direction of Engr-in - Charge Note : Superfical area of the concrete is measured.

470

-

-

... More
Bond coat: Applying zinc primer to the bars on all sides of the reinforcement and application of fepoxy bonding agent to of acrylic emulsion bonding agent (or) Epoxy bonding agent. This application shall be carried out for concrete structural bonding agent between old concrete surface to new concreteing all as specified and directed. Note : Superfical area of the concrete is measured

470

-

-

... More
Polymer Modified concrete: Providing and applying polymer modified cement concrte (1:1:2) in specfied ratio by using 15% polymer and 53 grade cement to RCC surfaces in case the damaged thickness of RCC exceeds 30mm, the thickness assumed max upto 100mm. etc complete as instructed and directed by Client/ Consultant

4.7

-

-

... More
Anti Caronation coating at out side of the concrete surface: Acrylic based plasto-elastic, crack - bridging protective coating system. Over the entire concrete surface including materials, machinery, labour tools etc all complete. Note :- Superfical area of the concrete is measured.

470

-

-

... More
Grouting: A shrinkage free low viscos epoxy resin based injection of epoxy resin (wet and submerged cracks) apply of nozzles to be fixed shrinkage free moisture insentive epoxy resin free flow grout. Note :- Superfical area of the concrete is measured.

120

-

-

... More
Drilling and fixing of copper nozzels in RC members : Drilling 10mm dia upto 300mm deep holes in structural members horizentally and vertically in stagged manner at the intervals as per specfications and drawings. Clean the holes by hair blower prior to fixing nozzels and insert 8mm dia. copper nozzels in holes for repair work and strengthening work of existing structure, materials machinery and menpower inclung etc, completed as per the direction of Engr-in-Charge. Note :- Injection of chemical grout will be paid separate line item. Superfical area of the concrete is measured.

120

-

-

... More
Ceiling of Cracks : Supply and apply a solvent -free, moisture tolerant, thixotropic, structural two-part adhisive. Mortar and concrete must be older than 28 days (depends on minimal requirement of strengths). Verify the substarte strength (concrete, masonary, natural stone). The substrate surface (all types) must be clean, dry and free from contaminants such as dirt,iol,grease, existing surface treatment and coatings etc. Steel substracts shall be removed. When using a thin layer adhesive, apply the mixed adhesive to the prepared surface with a spatula, trowel, notched towel, (or with hands protected with gloves). When applying as a repair mortar use form work. When using for bonding metal profiles onto vertical surfaces, support and press uniformly using props fro at least 12 hours, depending on the thickness applied (not more than 5mm) and the room temperature. Once hardened check the adhesion will be checked by tapping with a hammer.

560

-

-

... More
M&L for new reinforcement bars to the existing RCC member by using lokfix component chemical by drilling the 150mm deep hole of 16 mm dia and fill the chemical as per manufacturer instructions all as specified and directed. . Note : TMT bars will be measured and paid under separate item of schedule.

800

-

-

... More
Supply and application of 4mm thick Epoxy self levelling floor system with Nitofloor SL 4000 or equilent (As approved by GE) over a coat of epoxy primer Nitoprime 25 or equivalent (As approved by GE) including removal of existing damaged epoxy flooing and scarifying or grinding the surfaces to remove laitance with air blowers and cleaning the surface by water jetting and allowing to dry for 2 days complete all as specfied and directed. Note: (i) The rate by the contractor inclusive of construction joints as of flooring as appliacble and as directed by the manufacturer (ii)The work will be carried out by OEM/authorised applicator only.

3700

-

-

... More
M&L for RCC type B1 1:2:4 (using 20 mm graded stone aggregate) Reinforced cement concrete (nominal mix) in Chjja and like work complete all as specfied and directed.

4

-

-

... More
M&L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) all as specified and directed.

45

-

-

... More
Dismantling wrought iron or mild steel work of any description not otherwise provided for all as specified and directed.

7.4

-

-

... More
M&L framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 all as specified and directed.

600

-

-

... More
M&L for preparation of new surfaces of any description over 10cm in width or girth and applying one coat of synthetic enamel paint over a coat of red oxide/ zinc chrome complete all as specified and directed.

80

-

-

... More
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specfuied and directed

7

-

-

... More
M&L for brick work with sub- class ‘B’ bricks straight or curved on plan exc 6 M mean radius in CM 1:4 complete all as specfied and directed

28

-

-

... More
S & F for 2000 ltr capacity rotational moulded polye thylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I.

10

-

-

... More
M&L for preparation of new plastered surfaces of wall and applying two coats of distemper oil emulsion over a coat of primer with one coat birla putty complete all as specified and directed.

1319.22

-

-

... More
M&L for complete removal of existing treatment on walls and applying two coat of distemper oil emulsion over one coat of primer with one coat of birla putty complete all as specified and directed.

3957.67

-

-

... More
M&L for preparation of new plastered surfaces of ceiling and two coat of distempering with distemper oil emulsion over a coat of primer with one coat of putty complete all as specified and directed.

1316.03

-

-

... More
M&L for complete removal of existing treatment on ceiling and applying two coat of distemper oil emulsion over one coat of primer with one coat of putty complete all as specified and directed.

3948.07

-

-

... More
M&L for preparation of new plastered surfaces of walls and apply two coat of exterior weather proof emulsion over a coat of Alkaline resistance primer primer ( in bldg height upto 20 mtrs.) complete all as specified and directed.

4842.46

-

-

... More
M&L for complete removal of existing treatment on walls and apply two coats of exterior weather proof emulsion over a coat of Alkaline resistance primer primer complete all as specified and directed.

3513.69

-

-

... More
M&L for preparation of old painted steel surfaces of any descriptions over 10cm in width or girth and applying one coat of synthetic enamel paint over a coat of red oxide/ zinc chrome complete all as specified and directed.

2244.45

-

-

... More
M&L for preparation of old wooden surfaces and applying two coats of synthetic enamel paint over one coat of pink primer over 10 cm width or girth complete all as specified and directed.

360

-

-

... More
M&L for preparation of new wooden surfaces and applying two coat of synthetic enamel paint over one coat of pink primer over 10 cm width or girth complete all as specified and directed.

110

-

-

... More
M&L for complete removal of existing treatment on walls and apply two coat of plastic emulsion paint over a coat of Alkaline resistance primer primer complete all as specified and directed.

1676.11

-

-

... More
S&F 110 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls including taking down of old rain water pipes complete all as specfied and directed.

72

-

-

... More
S&F for 110mm dia PVC (SWR) bends any radius all as specified and directed.

8

-

-

... More
M&L for Post construction anti termite treatment along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron complete all as specfied and as directed

297

-

-

... More
M&L for treatment of soil under existing floors using emulsion @ one litre per hole 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors complete all as specfied and directed

1650

-

-

... More
M&L for treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specfied and directed

265

-

-

... More
S&F in repiairs 12mm thick Medium density fibre board, exterior grade, fixed to timber framework or fixed to aluminum frame work with rubber gacut complete all as specified and directed

120

-

-

... More
S&F Plates (plain or chequered) Fe-410- W(Gde E-250) quality B square cut or notched (ordinary and counter sunk) forming holes, without any attachment complete all as specfied and as directed.

1200

-

-

... More
S&F in repair 25mm bore galvanised steel tubes, medium grade including all necessary fittings complete all as specfied and as directed

150

-

-

... More
All as per item No. 1.92 above, but 20mm bore.

120

-

-

... More
S&F in repair 25mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specfied and directed

6

-

-

... More
All as per item No. 1.94 above, but 20mm bore.

5

-

-

... More
M&L for providing and fixing stainless steeel ( grade 304) railing made of hollow tubes , chanells, plates etc including welding, grinding, buffing, polishing and making curvature ( wherever required) and fitting the same with necessary stainless steel nuts and bolts complete including fixing the railing with necessary accessories & stainless steel dash fastners, stainless steel bolts etc of required size, on the top of floor or the side of waist slab with suitable arrangements complete all as specified and as directed

1400

-

-

... More
[SCHEDULE 'A' PART-II [E/M WORKS]

-

-

-

... More
Taking down old unsv copper /aluminium point wiring (light, fan.socket or power) complete including fixture and fittings such as switches,ceiling roses, pendants, regulators, sockets ,light fittings etc removing materials to store for keepin or for taking credit (credit for above items should be made as per conditions separately ) and making good disturbed surfaces of walls,floors etc., all as specified and directed.

826

-

-

... More
Taking down old UNSV DBs and main switches along with MCBs and MCCBs all as specified and directed.

58

-

-

... More
M&L concealed point wiring with with 1.5 sq mm (nominal area), PVC insulated, stranded single core unsheathed FRLS copper conductor cable drawn through with PVC conduit medium grade with all fittings and accessories of PVC conduit/ casing caping (like Tee, bend etc) complete fixed to walls etc with and including 1.5 sqmm (nominal area) PVC insulated stranded single core unsheathed FRLS copper cable as earth continity wire connecting to common earth point including fixing modular switch socket regulator etc. complete all as specified and directed including necessary chase cutting for conduits to walls, floors and sinking boxes and making good to walls, floors complete all as specified and directed.

-

-

-

... More
One light point point controlled by one 5 Amps switch one way

321

-

-

... More
One fan point controlled by one 5 Amps switch one way

45

-

-

... More
One 3/5 pin 5 Amp switch socket outlet on independent board

200

-

-

... More
One 3/5 pin 5 Amp socket outlet on same board.

10

-

-

... More
Supply & fix modular type switch 5 Amp oneway flush type all as specified and directed.

631

-

-

... More
S&F Modular switch socket outlet 2 in 1, 3 pin 5 Amp all as specified and directed.

210

-

-

... More
S&F modular coverplate with support plate for 3 modules or more with anodised metal boxes incl taking down old unsv one complete all as specified and directed.

460

-

-

... More
S&F modular coverplate with support plate for 8 modules or more with Anodised metal boxes incl taking down old unsv one complete all as specified and directed.

160

-

-

... More
M&L for concealed point wiring with with 2.5 sq mm (nominal area), PVC insulated, stranded single core unsheathed FRLS copper conductor cable drawn through with PVC conduit medium grade with all fittings and accessories of PVC conduit / casing caping (like Tee, bend etc) complete fixed to walls etc with and including 2.5 sqmm (nominal area) PVC insulated stranded single core unsheathed FRLS copper cable as earth continity wire connecting to common earth point for 3/5 pin socket outlet 15 Amps including necessary chase cutting for conduits to walls, floors and sinking boxes and making good to walls, floors complete all as specified and directed.

250

-

-

... More
S&F 6/15 Amps modular switch socket combination all as specified and directed.

250

-

-

... More
S&F Modular fan regulator 120W including taking down old UNSV one and all specified and directed.

18

-

-

... More
S&F ceiling rose, 3 phase /PVC/polycarbonate, isolated body all as specified and directed.

667

-

-

... More
S&F modular bell electric AC 240 volt, 50 Hz including dismantling taking down unsv one all as specified and as directed.

2

-

-

... More
S&F modular bell push piano type one way 5Amp, 240 volt incl dismantling taking down unsv one . all as specified and as directed

2

-

-

... More
S&F LED engagement light Red & Green including dismantling taking down unsv one all as specified and directed.

2

-

-

... More
Supply & fix LED recessed full open 2 x 2 feet with highly efficient light smoothy optics to deliver superior illuminous and energy saving of 36 watts complete all as directed.(To replace existing 4' tubelight fitting)

20

-

-

... More
Supply & fix LED batten with CRCA body,pre coated with white and prewired suitable for LED tube 2x20 watt 4'long alongwith 2 number of tube including dismantling and taking down all as specified and directed.

301

-

-

... More
S&F LED medium bay light 150 watt at roof truss level of wksp buildings and other places incl dismantling taking down unsv one any type all as specified and directed.

14

-

-

... More
S&F MCB, Single Pole, 6 to 32 amps, 240 Volts, 10 KA breaking cap, ‘’C” curve incl dismantling taking down unsv one all as specified and directed.

602

-

-

... More
S&F MCB, Four Pole, 63 amps, 240 Volts, 10 KA breaking cap, ‘’C” curve incl dismantling taking down unsv one all as specified and directed.

14

-

-

... More
S&F MCB, three Pole, 63 amps, 240 Volts, 10 KA breaking cap, ‘’C” curve incl dismantling taking down unsv one all as specified and directed.

15

-

-

... More
S&F MCB, Double Pole, 6 to 32 amps, 240 Volts, 10 KA breaking cap, ‘’C” curve incl dismantling taking down unsv one all as specified and directed.

36

-

-

... More
S&F MCCB, 16KA, 4 pole, with thermal magnetic trip unit, rated current 125amps complete with spider link incl dismantling taking down unsv one all as specified and directed (Suitable for MCCB incomer DB).

10

-

-

... More
S&F vertical MCB distribution board suitable for MCCB incomer, IP 43 protection, Double door, metal enclosure, TPN, 415 Volts, 12 way including dismantling taking down unsv one all as specified and directed.

10

-

-

... More
S&F doubledoor TPN DB 8 way double door with 200 amp rated bus bar all as specified and directed.

9

-

-

... More
S&F doubledoor TPN DB 4 way double door with 200 amp rated bus bar all as specified and directed.

5

-

-

... More
S&F MCB distribution board, IP 43 protection, Double door, metal enclosure, SPN, 230 Volts, 12 way incl dismantling taking down unsv one all as specified and directed.

11

-

-

... More
S&F MCB distribution board, IP 43 protection, Double door, metal enclosure, SPN, 230 Volts, 8 way incl dismantling taking down unsv one all as specified and directed.

23

-

-

... More
S&F DP MCB Metal box enclosure with din rail incl dismantling taking down unsv one all as specified and directed.

2

-

-

... More
S&F TP MCB Metal box enclosure with din rail including dismantling taking down unsv one all as specified and directed.

1

-

-

... More
M & L for sub main wiring (as per site requirement) with 2 runs of 2.5 sqmm FRLS grade PVC insulated copper conductor wire single core multistrand for phase & neutral, 2.5 sqmm FRLS grade PVC insulated copper conductor wire for earth continuity drawn in and including non metallic FRLS ISI marked PVC conduit medium grade dia with conduit accessories including taking down old UNSV one and,all as specified and directed. Note: (i) Cutting chases for DB &making good to wall shall be inclusive of quoted rate. (ii) If concealled wiring is asked at site cutting chases will be measured and paid separately.

800

-

-

... More
M & L for concealled sub main wiring (as per site requirement) wiring with 2 runs of 6 sqmm FRLS grade PVC insulated copper conductor wire single core multistrand for phase & neutral, 6 sqmm FRLS grade PVC insulated copper conductor wire for earch continuity drawn in and including non metallic FRLS ISI marked PVC conduit medium grade dia with conduit accessories including taking down old UNSV one and,all as specified and directed. Note: (i) Cutting chases for DB &making good to wall shall be inclusive of quoted rate. (ii) If concealled wiring is asked at site cutting chases will be measured and paid separately.

1300

-

-

... More
M & L for concealled sub main wiring (as per site requirement) wiring with 4 runs of 10 sqmm FRLS grade PVC insulated copper conductor wire single core multistrand for phase & neutral, 2 runs of 10 sqmm FRLS grade PVC insulated copper conductor wire for earth continuity drawn in and including non metallic FRLS ISI marked PVC conduit (heavy grade) with conduit accessories including taking down old UNSV one and,all as specified and directed by Engr-in-Charge. Note: (i) Cutting chases for DB &making good to wall shall be inclusive of quoted rate. (ii) If concealled wiring is asked at site cutting chases will be measured and paid separately.

1100

-

-

... More
M&L for cutting chases, pinning in, making good to facings where required and pointing in cement mortar (1:3) to ends or edges of landings, step cills, sunshades, shelves, lintels etc in brick walls and cutting chases for concealled water tubing or concealled conduit wiring etc and making good, cutting not ecc. 10 cm girth complete all as specified and as directed.

2560

-

-

... More
Supply and fix 220V AC, 50HZ, single pole and neutral sheet metal enclosure with a two pin and earth plug and socket complete with one single pole MCB of rating 20 Amps all as specified and directed.

43

-

-

... More
Supply and fix LED building security light 70W IP 66 rated including supply and fixing with 40mm dia medium grade GI pipe bracket 1.5 mtr long bent to shape, mounted on pole/wall with suitable clamps nuts and bolts and all accessories complete including connection with 3 core PVC insulated sheathed flexible cable with multistranded copper conductor cable from ceiling rose to fitting terminal including taking down old unsv one all as specified and directed

25

-

-

... More
Material and labour for shifting split type AC upto 2.0 tonne capacity from one location to another inside Dockyard and fixing including making necessary opening for suction and discharge and drain pipe line, brazing copper pipes after grouting of outdoor/indoor unit and making necessary electrical connection, recharging , testing and commissioning all as specified and directed

8

-

-

... More
M&L for servicing & rewinding of Ceiling fan size upto 1400 mm sweep after opening complete motor assy, bearings, bushings, removal of burnt copper wire, cleaning of core, inserting proper insulating paper in slots, winding with and as per existing size/turn of super enamelled copper wire, heating, vernishing, replacement of unsv bearings / bushings / capacitor pad / connector block, connection wire 3 core, assemble of rotor and stator unit with capacitor, connecting wire, capacitor pad, down rod, blades complete including painting to complete fan assy all as specified and directed.

20

-

-

... More
Taking down of exhaust fan upto 450 mm dia from wall, dismmanting complete fan assy, removing of motor and taking out for rewinding to civil workshop outside dockyard, complete rewinding with super enamelled copper wire as per existing size, heating, varnishing replacement of both end bearing and complete assemble of motor, transport been to ND(V), complete assemble of exhaust fan,fixing to orginal position, testing commisioning complete including painting to complete fan assy all as specified and directed.

31

-

-

... More
Repairing of pedestal fan, dismmanting complete fan assy, removing of motor and taking out for rewinding , complete rewinding with super enamelled copper wire as per existing size, heating, varnishing replacement of both end bearing and complete assemble of motor,painting, changing its bearings and capcitor,fixing to orginal position with complete set of fasteners, testing commisioning complete including painting to complete fan assy all as specified and directed.

18

-

-

... More
Supply and fix AC stand as per existing AC Model and mounting the out door unit of the split AC or window AC all as specified and directed.

8

-

-

... More
S&F only round shaped recess mounted LED Flat panel down lighter, 12watt,230V to POP/grid celing complete with all fixing accessories and including connecting up to ceiling rose with 0.5 sqmm two core copper flexible conductor cable all as specified and directed.

24

-

-

... More
S&F LED tube light fitting with LED tube, 2'long, 10 watt, CDL, 230 Volts , complete with all accssories internally pre wired incl dismantling taking down unsv FTL/CFL fiitings all as specified and directed.

24

-

-

... More
M&L for earthing with galvanised steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground earth pit not less than 2.25 m deep below ground level with top edge of the plate not less than 1.5 m below normal ground level connected to GI strip32x6 mm by means of nuts, bolts check nuts, washers of galvanised iron or steel all as shown in electrical plate No:5 of SSR Part I connected to earth test point including excavation work in any strata pcc chamber with PCC cover slab with GI protection pipe 40 mm dia light gde upto 7.5 mtr/20 mm dia tunnel pipe med grade but all as specified and directed by E-in-C.

35

-

-

... More
M&L for earth continuity conductor or main earth lead fixed to wall of batten or recess or chases or buried in ground or drawn in conduct/pipe or any other indicated situation for loop earthy etc of 32x6 mm all as specified and directed.

1000

-

-

... More
Taking down of Wall mounted fan upto 450 mm dia from wall, dismmenting complete fan assy, removing of motor and taking out for rewinding to civil workshop outside dockyard, complete rewinding with super enamelled copper wire as per existing size, heating, varnishing replacement of both end bearing and complete assemble of motor, transport been to ND(V), complete assemble of exhaust fan,fixing to orginal position, testing commisioning complete including painting to complete fan assy all as specified and directed

8

-

-

... More
Supply and fixing aluminium strip 25mm x 3.15mm complete with saddles and fixing screws for fitting the strip all as specified and directed. Note: Distance between 2 consecutive saddle should be less than 1 meter.

3180

-

-

... More
Supply and fixing air termination , single pointed aluminium rod 12mm dia and 300mm long complete all as specfied and as directed.

20

-

-

... More
Supply and fix test point terminal block made of gun metal or phorphorous bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specfied and as directed.

20

-

-

... More
Supply and fix MCB distribution board, including 4 pole MCB, 100 A 3 pole, as incomer with MCB 6-32 A as out going as per site requirement IP 43 protection, Double door, metal enclosure, TPN, 415 Volts, 4 way all as specified and directed.

4

-

-

... More
S&F hot galavanized wire mesh cable trays 105x300mm complete with trays,coupler,cover,and cover clip to support clamps, securing properly to support structure complete including dismantling of u/s existing cable trays from building wall more than 3 M height from FL all as specified and as directed.

200

-

-

... More
S&F of cable rack/tray support made with structural steel section (Fe-290, Gde E165) pre-welded, on wall, placing in position and fixing to wall with fastner steel bolt not less than 16mm dia including painting with one coat of red oxide and two coat of black synthetic enamel paint all as specified and as directed.

500

-

-

... More
M&L for disconnecting cable of size 16 sqmm to 185sqmm and taken out from trnches/duct/wall/cable tray, clean trench/duct/wall and relaying cable with proper clamp and connection all as specfied and as directed.

600

-

-

... More
S&F Spot LED light 15W with modern design, compact size with high power LED to provide focussed light suitable driver and adapter complete all as directed incl taking down old unsv one all as specified and directed.

15

-

-

... More
S&F 100A MCCB Metal box enclosure incl dismantling taking down unsv one all as specified and directed.

5

-

-

... More
S&F 250A MCCB Metal box enclosure incl dismantling taking down unsv one all as specified and directed.

1

-

-

... More
M&L for Dismantling old LT panel carefully and supply, installation, testing and commissioning of floor mounted cubical/trunk type indoor made out of 2 mm thick CRCA steel sheet traded and powder coated, prewired, factory made , with provision for one incoming and multiple outgoing as mentioned below, with suitable CT's, individual comparment dust and vermin proof, weather proof electrical panel and with Godrej type lock, cable glands etc. and consisting of the following all as specified and as directed :- (i) Copper ETP Bus bar of capacity 800 Amps for phases and neutral. (ii) MCCB 400 Amps 4 pole 36KA as incomer-01 Nos. (iii) MCCB 200 Amps 3 pole 36 kA -01 Nos out going (iv) MCCB 63 Amps three pole breaking capacity 16 kA -03 Nos as out going

1

-

-

... More
(v) TPN DB(including MCB) 6 Way as out going-01 No (vi) Digital Ammeter 0-2000 Amps-02 Nos . (vii) Digital voltmeter 0-500 Volts-02 Nos . (viii) Indication lamps RYB -03 sets. Note : (i) Drawing for LT panel showing layout of incoming and outgoing switch gear with capacity before errection shall be approved by Engr-in-Charge. (ii) Unit rate quoted include for necessary grouting / chipping of concrete and Anchor fastners and providing necessary PCC foundation to fix the LT Panel enclosure.(iii) quoted rate are inclusive of copper Bus bar. (iv) MCCB/ACB will be measured and paid separately.(v) LT panel might be installed at 1st or 2nd floor therefore necessary shall be made by the contactor and rates are inclusive of the quoted rate.

-

-

-

... More
M&L for Dismantling old LT panel carefully and supply, installation, testing and commissioning of floor mounted cubical/trunk type indoor made out of 2 mm thick CRCA steel sheet traded and powder coated, prewired, factory made , with provision for one incoming and multiple outgoing as mentioned below, with suitable CT's, individual comparment dust and vermin proof, weather proof electrical panel and with Godrej type lock, cable glands etc. and consisting of the following all as specified and as directed :- (i) Copper ETP Bus bar of capacity 1200 Amps for phases and neutral. (ii) ACB 630 Amps 4 pole 36KA as incommer-01 Nos (iii) MCCB 400 Amps 3 pole 36 kA -01 Nos out going (iv) MCCB 63 Amps three pole breaking capacity 16 kA -03 Nos as out going .

1

-

-

... More
(v) Digital Ammeter 0-2000 Amps-02 Nos . (vi) Digital voltmeter 0-500 Volts-02 Nos . (vii) Indication lamps RYB -03 sets. Note : (i) Drawing for LT panel showing layout of incoming and outgoing switch gear with capacity before errection shall be approved by Engr-in-Charge. (ii) Unit rate quoted include for necessary grouting / chipping of concrete and Anchor fastners and providing necessary PCC foundation to fix the LT Panel enclosure.(iii) quoted rate are inclusive of copper Bus bar. (iv) MCCB/ACB will be measured and paid separately.(v) LT panel might be installed at 1st or 2nd floor therefore necessary shall be made by the contactor and rates are inclusive of the quoted rate.

-

-

-

... More
M&L for Dismantling old LT panel carefully and supply, installation, testing and commissioning of floor mounted cubical/trunk type indoor made out of 2 mm thick CRCA steel sheet traded and powder coated, prewired, factory made , with provision for one incoming and multiple outgoing as mentioned below, with suitable CT's, individual comparment dust and vermin proof, weather proof electrical panel and with Godrej type lock, cable glands etc. and consisting of the following all as specified and as directed :- (i) Copper ETP Bus bar of capacity 800 Amps for phases and neutral. (ii) MCCB 400 Amps 4 pole 36KA as incommer-01 Nos (iii) MCCB 250 Amps 3 pole 36 kA -01 Nos out going (iv) MCCB 100 Amps three pole breaking capacity 16 kA -03 Nos as out going

1

-

-

... More
(v) MCCB 63 Amps three pole breaking capacity 16 kA -03 Nos as out going (vi)TPN DB 4 Way(including MCB) as out going-01 No (vii) Digital Ammeter 0-2000 Amps-02 Nos . (viii) Digital voltmeter 0-500 Volts-02 Nos . (ix) Indication lamps RYB -03 sets. Note : (i) Drawing for LT panel showing layout of incoming and outgoing switch gear with capacity before errection shall be approved by Engr-in-Charge. (ii) Unit rate quoted include for necessary grouting / chipping of concrete and Anchor fastners and providing necessary PCC foundation to fix the LT Panel enclosure.(iii) quoted rate are inclusive of copper Bus bar. (iv) MCCB/ACB will be measured and paid separately.(v) LT panel might be installed at 1st or 2nd floor therefore necessary arrangements shall be made by the contactor and rates are inclusive of the quoted rate.

-

-

-

... More
M&L for Dismantling old LT panel carefully and supply, installation, testing and commissioning of floor mounted cubical/trunk type indoor made out of 2 mm thick CRCA steel sheet traded and powder coated, prewired, factory made , with provision for one incoming and multiple outgoing as mentioned below, with suitable CT's, individual comparment dust and vermin proof, weather proof electrical panel and with Godrej type lock, cable glands etc. and consisting of the following all as specified and as directed :- (i) Copper ETP Bus bar of capacity 1200 Amps for phases and neutral. (ii) ACB 800 Amps 4 pole 36KA as incomer-01 Nos (iii) MCCB 400 Amps 3 pole 36 kA -02 Nos out going (iv) MCCB 200 Amps three pole breaking capacity 16 kA -02 Nos as out going

1

-

-

... More
(v) MCCB 63 Amps three pole breaking capacity 16 kA -03 Nos as out going (vi) MCCB 32 Amps three pole breaking capacity 16 kA -03 Nos as out going . (vii) Digital Ammeter 0-2000 Amps-02 Nos . (viii) Digital voltmeter 0-500 Volts-02 Nos . (ix) Indication lamps RYB -03 sets. Note : (i) Drawing for LT panel showing layout of incoming and outgoing switch gear with capacity before errection shall be approved by Engr-in-Charge. (ii) Unit rate quoted include for necessary grouting / chipping of concrete and Anchor fastners and providing necessary PCC foundation to fix the LT Panel enclosure.(iii) quoted rate are inclusive of copper Bus bar. (iv) MCCB/ACB will be measured and paid separately.(v) LT panel might be installed at 1st or 2nd floor therefore necessary shall be made by the contactor and rates are inclusive of the quoted rate.

-

-

-

... More
M&L for Dismantling old LT panel carefully and supply, installation, testing and commissioning of floor mounted cubical/trunk type indoor made out of 2 mm thick CRCA steel sheet traded and powder coated, prewired, factory made , with provision for one incoming and multiple outgoing as mentioned below, with suitable CT's, individual comparment dust and vermin proof, weather proof electrical panel and with Godrej type lock, cable glands etc. and consisting of the following all as specified and as directed :- (i) Copper ETP Bus bar of capacity 800 Amps for phases and neutral. (ii) MCCB 400 Amps 4 pole 36KA as incommer-01 Nos (iii) MCCB 200 Amps 3 pole 36 kA -01 Nos out going (iv) MCCB 100 Amps three pole breaking capacity 16 kA -02 Nos as out going

1

-

-

... More
(v) MCCB 63 Amps three pole breaking capacity 16 kA -04 Nos as out going. (vi) TPN DB (including MCB) 4 Way as out going-01 No (vii) Digital Ammeter 0-2000 Amps-02 Nos . (viii) Digital voltmeter 0-500 Volts-02 Nos . (ix) Indication lamps RYB -03 sets. Note : (i) Drawing for LT panel showing layout of incoming and outgoing switch gear with capacity before errection shall be approved by Engr-in-Charge. (ii) Unit rate quoted include for necessary grouting / chipping of concrete and Anchor fastners and providing necessary PCC foundation to fix the LT Panel enclosure.(iii) quoted rate are inclusive of copper Bus bar. (iv) MCCB/ACB will be measured and paid separately.(v) LT panel might be installed at 1st or 2nd floor therefore necessary shall be made by the contactor and rates are inclusive of the quoted rate.

-

-

-

... More
M&L for Dismantling old LT panel carefully and supply, installation, testing and commissioning of floor mounted cubical/trunk type indoor made out of 2 mm thick CRCA steel sheet traded and powder coated, prewired, factory made , with provision for one incoming and multiple outgoing as mentioned below, with suitable CT's, individual comparment dust and vermin proof, weather proof electrical panel and with Godrej type lock, cable glands etc. and consisting of the following all as specified and as directed :- (i) Copper ETP Bus bar of capacity 800 Amps for phases and neutral. (ii) ACB 800 Amps 4 pole 36KA as incomer-01 Nos (iii) MCCB 400 Amps 3 pole 36 kA -02 Nos out going (iv) MCCB 200 Amps three pole breaking capacity 16 kA -02 Nos as out going

1

-

-

... More
(v) MCCB 63 Amps three pole breaking capacity 16 kA -04 Nos as out going (vi) TPN DB (Including MCB) 4 Way as out going-01 No (vii) Digital Ammeter 0-2000 Amps-02 Nos . (viii) Digital voltmeter 0-500 Volts-02 Nos. (ix) Indication lamps RYB -03 sets. Note : (i) Drawing for LT panel showing layout of incoming and outgoing switch gear with capacity before errection shall be approved by Engr-in-Charge. (ii) Unit rate quoted include for necessary grouting / chipping of concrete and Anchor fastners and providing necessary PCC foundation to fix the LT Panel enclosure.(iii) quoted rate are inclusive of copper Bus bar. (iv) MCCB/ACB will be measured and paid separately.(v) LT panel might be installed at 1st or 2nd floor therefore necessary shall be made by the contactor and rates are inclusive of the quoted rate.

-

-

-

... More
Supply only 400A MCCB 4 pole 415V fixed type with 36KA breaking capacity incl dismantling taking down unsv one all as specified and directed.

3

-

-

... More
S&F 63A MCCB 3 pole 415V fixed type with breaking capacity incl dismantling taking down unsv one all as specified and directed.

17

-

-

... More
S&F 100A MCCB 3 pole 415V fixed type with 16KA breaking capacity including dismantling taking down unsv one all as specified and directed.

13

-

-

... More
S&F 250A MCCB 3 pole 415V fixed type with 36KA breaking capacity incl dismantling taking down unsv one all as specified and directed.

2

-

-

... More
Supply only 400A MCCB 3 pole 415V fixed type with 36KA breaking capacity incl dismantling taking down unsv one all as specified and directed.

4

-

-

... More
Supply only 200A MCCB 3 pole 415V fixed type with 36KA breaking capacity incl dismantling taking down unsv one all as specified and directed.

6

-

-

... More
Supply only 32A MCCB 3 pole 415V fixed type with 16KA breaking capacity incl dismantling taking down unsv one all as specified and directed.

3

-

-

... More
Supply only ACB 4 Pole, 415 V, Manual Drawout type with microprocessor release of capacity 630 Amps complete all as specified and directed.

1

-

-

... More
Supply only ACB 4 Pole, 415 V, Manual Drawout type with microprocessor release of capacity 800 Amps complete all as specified and directed.

2

-

-

... More
Supply and fixing XLPE insulated, armoured heavy duty cable with aluminium conductor, 1100 volts grade cross section area 35 sqmm 4 core incl dismantling taking down unsv one from wall, cable tray, trench complete all as specified and as directed

500

-

-

... More
Supply, laying and connecting up through surface/wall/duct/cable tray, cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) 1100 volts grade with straded aluminium conductor of size 240 sqmm 3.5 core including necessary lux complete incl taking down old unsv one. all as specified and directed.

200

-

-

... More
S&F LT heat shrink cable end termination for cable sizes 120 to 240 sqmm 3.5 core, 1100 volts grade by cutting out damaged portion of XLPE insulated cable ends for the following sizes including disconnection cable ends from ACB/MCCB/Busbar and reconnection with existing new stainless steel bolts of size not less than 16 mm dia and 40 mm long complete all as specified and directed.

24

-

-

... More
Supplying and laying synthetic rubber insulated mats 2 mm thick for voltage upto 3.3 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2M x 1M all as specified and directed.

12

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.