Military Engineer Services Tender
To know what Andhra Pradesh government has posted about any AP etender, Bidassist helps us to get a one-stop platform where a registered bidder can have access to the details on each and every eprocurement tender. There is no need to provide the details on the AP E-procurement website i.e. https://www.apeprocurement.gov.in as BidAssist helps us find the specific etender we're looking for. BidAassist has collated each and every Eproc Andhra Pradesh Tender on its website.
Military Engineer Services - MES Tender
Civil And Construction
Civil Works Others
Eprocure
Opening Date20 May 2024
Closing DateCancelled
Tender Amount₹ 25,48,00,000
Costs
EMD
₹ 15,00,000Document Cost
₹ 3,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_MES_620473_2Tender No
85429Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Lumpsum price worked out by the contractor for "INTERNAL ELECTRIFICATION", as listed in Schedule "A" Part – III
1
-
200160.28
... More
Lumpsum price worked out by the contractor for "INTERNAL WATER SUPPLY", as listed in Schedule "A" Part – IV
1
-
18545.14
... More
Lumpsum price worked out by the contractor for "SEWAGE DISPOSAL", as listed in Schedule "A" Part – V
1
-
365516.64
... More
Lumpsum price worked out by the contractor for "EXTERNAL WATER SUPPLY", as listed in Schedule "A" Part – VI
1
-
228807.89
... More
Lumpsum price worked out by the contractor for "EXTERNAL ELECTRIFICATION", as listed in Schedule "A" Part – VII
1
-
899880.24
... More
Lumpsum price worked out by the contractor for "ROADS /PATH/HARD STANDING/ CULVERT", as listed in Schedule "A" Part – VIII
1
-
3899484.24
... More
Lumpsum price worked out by the contractor for "AREA DRAINAGE", as listed in Schedule "A" Part – IX
1
-
1378168.53
... More
Lumpsum price worked out by the contractor for "FIRE FIGHTING SYSTEM", as listed in Schedule "A" Part – X
1
-
4019547.75
... More
Lumpsum price worked out by the contractor for "FIRE ALARM & DETECTION SYSTEM ", as listed in Schedule "A" Part – XI
1
-
653752
... More
Lumpsum price worked out by the contractor for ""LIGHTENING PROTECTION ", as listed in Schedule "A" Part – XII
1
-
255492.23
... More
Lumpsum price worked out by the contractor for "DISMANTLING/ DEMOLITION", as listed in Schedule "A" Part – XIII
1
-
2165492.1
... More
Lumpsum price worked out by the contractor for "PILE FOUNDATION", as listed in Schedule "A" Part – XIV
1
-
28259275.17
... More
Schedule "A" Part - XV: (Miscellaneous Items) ( Internal Electrification, Internal water supply, External Water Supply, External Electrification, Road/Path/ Hrad standing/ culvert, Fire fighting & Fire alarm, Sewage Disposal, Lifts, Avialtion Light, DG Set, EV point, Pile foundation and Outsourcing of Comprehensive Maintenance of Lifts)
-
-
-
... More
Internal Electrification
-
-
-
... More
M&L for Ponit wiring with 1.5 sqmm PVC insulated and unsheathed copper conductor cable multistranded 1100 Volts grade, FRLS, ISI marked drawn through and inculding non metallic PVC rigid concealed conduit and conduit accessories, medium grade, ISI marked, concealed to wall or surface mounted on pillars/columns including provn of box type switchboard consisting of pre fabricated pressed steel terminal box of suitable size made out of 1.2 mm thick sheets, for mounting modular brackets,with and including modular brackets and switch plates as required at site for fixing modular type switches, sockets etc inculding one run of 1.5 sqmm PVC insulated unsheathed copper cable for earth continuity green in colour, connected to earth duly complete all as specified and directed for One light point controlled by one switch :-
Note: (a) The PVC conduit shall be concealed and switch boards shall be flush to wall. (b) On columns/ pillars the box type switchboards surface mounted with necessary PVC conduit upto ceiling/nearest junction tapping shall be surface type conduit and quoted rate deemed to be inclusive for the same.(c) The quoted rate inclsuive necessary modules any type as per requirement incl all accessories complete
176
-
-
... More
M&L for Ponit wiring with 1.5 sqmm PVC insulated and unsheathed copper conductor cable multistranded 1100 Volts grade, FRLS, ISI marked drawn through and inculding non metallic PVC rigid concealed conduit and conduit accessories, medium grade, ISI marked, concealed to wall or surface mounted on pillars/columns including provn of box type switchboard consisting of pre fabricated pressed steel terminal box of suitable size made out of 1.2 mm thick sheets, for mounting modular brackets,with and including modular brackets and switch plates as required at site for fixing modular type switches, sockets etc inculding one run of 1.5 sqmm PVC insulated unsheathed copper cable for earth continuity green in colour, connected to earth duly complete all as specified and directed for One fan (ceiling fan/Ex.fan) point controlled by one switch :-
Note: (a) The PVC conduit shall be concealed and switch boards shall be flush to wall. (b) On columns/ pillars the box type switchboards surface mounted with necessary PVC conduit upto ceiling/nearest junction tapping shall be surface type conduit and quoted rate deemed to be inclusive for the same.(c) The quoted rate inclsuive necessary modules any type as per requirement incl all accessories complete
30
-
-
... More
All as per item No.17 above but for each additional light point on the same switch circuit of item No 17 complete all as specefied and directed.
210
-
-
... More
All as per item No.17 above but One 3 pin socket outlet 06 amps socket on independent board with 1.5 sqmm FRLS PVC wire for phase and neutral and one run of 1.5 sqmm copper cable green in colour for earth continuty conductor complete all as specefied and directed.
18
-
-
... More
All as per item No.17 above but One 3 pin socket outlet 5 amps on the same board with other switches, with cables 1.5 sq.mm size FRLS PVC wire for phase and neutral and one run of 1.5 sqmm copper cable green in colour for earth continuty conductor complete all as specefied and directed.
14
-
-
... More
All as per item No. 17 above but One 3 pin socket outlet 15 amps socket on independent board with 2.5 sqmm FRLS PVC wire for phase and neutral and one run of 2.5 sqmm copper cable green in colour for earth continuty conductor complete all as specefied and directed.
15
-
-
... More
All as per item No. 17 above but one light point controlled by two Nos of two way switch complete all as specefied and directed.
10
-
-
... More
S&F 1200 mm sweep ceiling fan with blades, down rods, modular type electronic regulator with accessories 230 V, with minimum air delivery 210 CFM with service value 6.0, BEE five star rated with brushless direct current motor (BLDC) with and including flexible copper wire 1 sqmm from ceiling rose to connector of ceiling fan complete all as specified and as directed.
19
-
-
... More
S&F Exhaust fan made out of sturdy engineering plastic complete with louvers shutter, 230 Volt, 50 Hz, RPM 1200, copper winding of sweep 250 mm, fixed on wall making opening, fixing and making good the distrubed surfaces etc complete with and inclussive of making necessary electric connection from ceiling rose to fan through 1 sqmm twin core flexible wire all as spcified and as directed.
3
-
-
... More
S&F exhaust fan, steel body AC single Phase. 230 V of size 300mm sweep with, blades, and frame and louvers fixed on wall making opening, fixing and making good the distrubed surfaces etc complete with and inclussive of making necessary electric connection from ceiling rose to fan through 1 sqmm twin core flexible wire all as spcified and as directed.
8
-
-
... More
S&F Energy efficient LED tube light fitting with tube 9 W or nearest size, 240V, 50 Hz surface mounted, decorative LED lighting fixture with extruded polycarbonate environmental friendly, energy efficient ready to use pack of complete with mounting bracket etc including connecting up with 1.0 sq mm 3 core flexible copper conductor cable complete all as specified and directed. Note :- The LED light fittings shall be min IP 20, with luminous efficiency 100 lumens/watt, CRI80%, PF0.95, warm white type.
2
-
-
... More
S&F Energy efficient LED tube light fitting with tube 18 W or nearest size, 240V, 50 Hz surface mounted, decorative LED lighting fixture with extruded polycarbonate environmental friendly, energy efficient ready to use pack of complete with mounting bracket etc including connecting up with 1.0 sq mm 3 core flexible copper conductor cable complete all as specified and directed. Note :- The LED light fittings shall be min IP 20, with luminous efficiency 100 lumens/watt, CRI80%, PF0.95, warm white type.
28
-
-
... More
S&F Energy efficient 1x1 feet flat panel for surface mounting LED light fitting with LED fixture 15 W or nearest size, 240 V, 50 Hz surface mounted, with extruded polycarbonate environmental friendly, energy efficient ready to use pack of complete with mounting bracket etc including connecting up with 1.0 sq mm 3 core flexible copper conductor cable complete all as specified and directed. Note :- The LED light fittings shall be min IP 20, with luminous efficiency 100 lumens/watt, CRI80%, PF0.95, warm white type.
10
-
-
... More
S&F Energy efficient 2x2 feet flat panel for surface mounting LED light fitting with LED fixture 36 W or nearest size, 240V, 50 Hz surface mounted, with extruded polycarbonate environmental friendly, energy efficient ready to use pack of complete with mounting bracket etc including connecting up with 1.0 sq mm 3 core flexible copper conductor cable complete all as specified and directed. Note :- The LED light fittings shall be min IP 20, with luminous efficiency 100 lumens/watt, CRI80%, PF0.95, warm white type.
330
-
-
... More
S&F LED Security light fitting with tube 30 W new generation Energy saving & environmental frindly long life made up of pressure die cast aluminium housing with high efficient LED as lighting source and PC cover having top opening seperate driver compartment with IP66 protection pre wired with 1.0 Sq mm copper conductor cable upto connector including 1.5 m long GI Tubing light grade of 32mm dia bend to shape for fixing on wall/pole with suitable MS brackets nuts and bolts etc compelte all as specified and as directred. Note : The LED light fittings shall be min IP 65, with luminous efficiency 100 lumens/watt, CRI80%, PF0.95, warm white type
20
-
-
... More
M&L for submain wiring complete with earth wire of PVC insulated multistranded copper conductor FRLS cable, ISI marked with and inclussive of suitable size PVC rigid counduit concealed to wall/roof, and PVC wire of size 2x4 sqmm for phase and neutral duly colour coded and 1x4 sqmm for earth continuity conductor green in colour complete all as specified and as directed.
Note :(i) Two run of 4.0 Sqmm + one run of 4.0 Sqmm as a earth wire cable + one run of PVC conduit shall be measured as an one Unit. (ii) On column/ Pillars the PVC conduit shall be surface mounted with necessary fittings.
250
-
-
... More
S&F concealed in wall Vertical MCB DB double door type, VTPN 6 way 415V, 50Hz , IP 43 protection with 200 A rated bus bar, including provision for fixing MCCB FP 125 A as incommer and outgoing circuits MCB SP/TP complete, fill empty way with blanking plates complete all as specefied and directed. Note : MCCB and MCBs shall be measured and paid seperately. (For EV Points-4 Nos and Car washing plant -1 Nos)
1
-
-
... More
S&F surface mounted Vertical MCB DB double door type, VTPN 6 way 415V, 50Hz , IP 43 protection with 200 A rated bus bar, including provision for fixing MCCB FP 125 A as incommer and outgoing circuits MCB SP/TP complete, fill empty way with blanking plates complete all as specefied and directed. Note : MCCB and MCBs shall be measured and paid seperately. (For EV Points-4 Nos and Car washing plant -1 Nos)
4
-
-
... More
S&F concealed in wall Vertical MCB DB double door type, VTPN 4 way 415V, 50Hz, IP 43 protection with 200 A rated bus bar, including provision for fixing MCCB FP 125 A as incommer and outgoing circuits MCB SP/TP complete, fill empty way with blanking plates complete all as specefied and directed. Note : MCCB and MCBs shall be measured and paid seperately. (For Multilevel car parking Bldg lighting DB)
1
-
-
... More
S&F concealed in wall MCB DB. double door type, SPN 12 way sheet steel phospetised powder painted with 200 A rated bus bar 240 V neutral link, IP : 43 protection complete all as specified and directed.
4
-
-
... More
S&F surface mounted MCB DB. double door type, SPN 12 way sheet steel phospetised powder painted with 200 A rated bus bar 240 V neutral link, IP : 43 protection complete all as specified and directed.
6
-
-
... More
S&F concealed in wall MCB DB. double door type, SPN 08 way sheet steel phospetised powder painted with 200 A rated bus bar 240 V nautral link, IP : 43 protection, complete all as specified and directed.
1
-
-
... More
S&F surface mounted MCB DB. double door type, SPN 08 way sheet steel phospetised powder painted with 200 A rated bus bar 240 V nautral link, IP : 43 protection, complete all as specified and directed.
2
-
-
... More
S&F concealed in wall MCB DB. double door type, Single pole and neutral 4 way sheet steel phospetised powder painted with 200 A rated bus bar 240 V nautral link, IP : 43 protection, complete all as specified and directed (for lift machine room).
1
-
-
... More
S&F surface mounted MCB DB. double door type, Single pole and neutral 4 way sheet steel phospetised powder painted with 200 A rated bus bar 240 V nautral link, IP : 43 protection, complete all as specified and directed (for lift machine room).
1
-
-
... More
M&L for earthing complete with GI steel plate electrode 600x600x6 mm, burried directly in ground (earth pit not less than 2.25 m deep below ground level)with top edge of the plate not less than 1.5 m below normal groundlevel, connected to GI strip of 25x4 mm by means of bolts, nuts, check nuts and washers of GI all as shown in electrical plate No-3 of SSR Part-I connected to earthing test point all as specified or indicated including excavation and connected earth work in hard/dense soil, PCC 1:3:6 type C-1 as in pit, 20mm dia GI pipelight grade for watering pipe and 32 mm bore GI light grade for earth lead protection pipe connected upto DBs, and suitable CI top cover with handle, funnel, strainer,charcoal, salt and testing on completion all as specified and directed. Note- Rate quoted deemed to be include excavation and earth work in any type of soil with PCC workcomplete all as specefied and directed.
Note: GI earth strip upto 7.5 m shall be deemed to be included in the quoted lumpsum and beyond 7.5 m shall be measured and paid separately under relavent item.
8
-
-
... More
Internal Water Supply
-
-
-
... More
S&F Bib taps two way, cast copper alloy fancy type chromium plated screwed down for size of 15 mm inner dia, suitable fo 16 mm outer dia CPVC pipes complete all as specified and as directed. Note: The maximum flow rate will be 03 LPM
2
-
-
... More
S&F health faucet chromium plated , fancy type with steel flexible complete of size of 15 mm dia suitable for 16 mm dia outer dia CPVC pipes complete all as specified and as directed.
Note: The maximum flow rate will be 03 LPM
2
-
-
... More
Sewage Disposal
-
-
-
... More
S&F 900x900x100 mm size Steel Fibre Rinforced Concrete (SFRC) Cover with frame, extra heavy duty, Grade (EDH-35) conforming to IS 12592-2002 and ISI marked, set in CM 1:4 complete all as specified and directed.
4
-
-
... More
External Water Supply
-
-
-
... More
M&L for valve chamber of internal size 750x750x750mm comprising of 50mm thick PCC 1:5:10 type E2 foundation, 200mm thick brick wall in CM 1:6, 15mm thick plastering in CM 1:4 internally and externally up to 50mm below GL, 100mm thick PCC 1:3:6 type B1 as in copings, 3mm thick MS sheet cover with suitable hinges and locking arrangement, painting steel surfaces with two coats of synthetic enamel paint over a coat of redoxide zinch rich primer including necessary earth work and excavation in any type of soil complete all as specified and as directed.
4
-
-
... More
Cutting existing steel tubing for alterations or additions necessarily done in position without taking down and inserting CI Tees of size 300 mm, CI reducers of size 300 mm to 80 mm, mechanical joint collar of size 300 mm complete for tapping all as specified and as directed.
1
-
-
... More
External Electrification
-
-
-
... More
Design, Manufacture, Supply, Installation, Testing and Commissioning of 11 kV / 0.433 kV, 500 kVA OEM Factory Manufactured, Factory Tested ready to install and connections type Compact Substation with an outdoor enclosure, equipped with 500 kVA oil (ONAN) cooled Transfomer, 3 Way, 11 kV Motorised/Manual Ring Main Unit (SF6 Gas Insulated Switchgear) consisting of 2 Nos, 630 A 11 kV Load Breaking Switch & 01 Nos VCB SF6 Gas insulated Vacuum Circuit Breaker and with associated LT switchgears having incomer of ACB 800 A 50 kA 01 No with outgoing of MCCB 400A 36 kA - 02 Nos (one for EV panel and one spare), MCCB 200 A 35 kA 03Nos (one fire panel, one APFC panel and one spare) and MCCB 63-80 A, 16 kA- 03Nos (one for DG AMF panel, Bldg Panel and one spare) as secondary side control complete with HT Cable interconnection in between Transformer and RMU and suitable sized Busbar between Transformer and LV Incoming Main Switchgear and Internal earthing connections by GI Strips all as a single transport unit complete all as specified as detailed below :-
1
-
-
... More
(a) Enclosure: Outdoor type Galvansied enclosure having modular construction with 2mm thick Galvanized Sheet Steel in Corrugated / Louvered design type wall design for better heat dissipation and providing robust construction. The degree of protection for HT & LT switchgear compartment shall be IP54 & degree of protection of transformer compartment of the enclosure shall be minimum IP34. The enclosure exterior shall be painted with polyurethane paint / epoxy powder coated and tropicalised to Indian weather conditions. Each compartment shall be provided with the door and pad locking arrangement. Doors of transformer compartment are fitted with Arc reflectors from the inside for providing better safety. The Compartment illumination lamp with door-operated switch shall be provided for each compartment. Structure of the substation shall be able to withstand the gross weight of all equipment. The Compact Substation shall be provided with lifting beams and hooks for easy installation at site and it shall be possible to transport the equipment along with Transformer, RMU & LT Panel from one site to another.
-
-
-
... More
(b) HT Switchgear (Inside Compact Sub-Station): Three way 11 kV, 630 A, 21 kA / 3 Sec Non-Extensible Ring Main Unit / Compact Switchgear with Copper Busbar, consisting of 630 A, Two Numbers (As incomer) fixed Manual/ Motorised Load Break Switches & One Numbers Fixed Manual/Motorised SF6 insulated Vacuum Circuit Breakers (As Outgoing) in SF6 Gas insulated sealed for life minimum 2 mm thickness SS 441 stainless steel tank IP 67 degree of protection with Air Insulated Metering Module along with FRTU, One Number fault passage indicator shall be provided for each Load Break Switch with 1 NO + 1 NC Contact, One Number manometer shall be provided for outgoing feeders, One set of 100/1 A, 2.5 VA, Class 1.0 for metering & One set of 100 / 1A, 2.5 VA, CL 5P 10 Current Transformers shall be provided, One number of Digital Multifunction Meter with RS 485 Port shall be provided for VCB Feeders, One Set of 11 kV / RT3 / 110 / RT3, Class 1.0, 20 kVA PT shall be provided in Metering Module. Vacuum Circuit Breakers shall be with self-powered micro processor based Numerial Over Current and Earth Fault Relay having Charged Open / Closing Mechanism, On / Off Indicators, Mechanical Operation Counters etc. Interconnection between RMU and Transformer shall be using suitable Aluminium unarmoured 11 KV (UE) 3runs x 1 Core x 240 Sq.mm XLPE cable.
-
-
-
... More
(c) Transformer (Inside Compact Sub-Station): 500 kVA, 11 kV / 433 V, 3 Phase, 50 Hz, DYn 11, ONAN Cooling oil filled type, Copper Wound, CRGO Core Transformer with OLTC of range +5% to -15% in steps of 1.25% on HT side of transformer, having Primary Voltage (HT) 11 kV and Secondary Voltage (LT) of 433 Volts, Delta connected on 11 kV Side & Star connected on 433 Volts side, designed & constructed with particular reference to Tropical Condition, conforming to IS:1180 Level 2 BIS marked and BEE star levelled with latest amendment – 1 Nos.
-
-
-
... More
(d) LV Switchgear (Inside Compact Sub-Station): 433 Volts, indoor LV Panel with Aluminium Busbars (100% for Phase & 50% for neutral, fabricated using 2 mm thick CRCA Sheet Steel, Ingress Protection IP4X, Compartmentalised complete with internal wiring consisting of following:
(i) LT switchgears having incomer of ACB 800A 50KA 01 No with outgoing of MCCB 400A 36KA - 02 nos (one for EV panel and one spare), MCCB 200A 35KA 03Nos (one fire panel, one APFC panel and one spare) and MCCB 63-80A, 16KA- 03Nos (one for DG AMF panel, Bldg Panel and one spare) (ii) Metering for Incomer: EM6433 Energy kWH Meter, LT Metering CT’s, 2500 / 1A, Cast Resin Type, Class - 0.2 – 1 Set, R, Y, B, ON, OFF, Trip LED Indicating Lamps – 1 Set, Control MCB, SP, 6 Amps – As required (iii) Outgoing : TPN Aluminium busbar of 3750 Amps rated with porcelain based insulators and PVC insulation sleeves with proper colour code
-
-
-
... More
(e) Compact Substation shall be outdoor Plinth Mounted Type. The rate quoted is deemed to be including the cost of Erection, Commissioning of Compact Substation and Civil work such as Construction of foundation with PCC 1:1.5:3, with plastering for the installation of Compact Substation of required size including trench for the cabling work etc complete in all respect. However the bidder shall furnish the foundation details/GA drawings of CSS for approval of GE as per OEM recomendation before executing the work, CSS should be supplied through OEM only. (f) Compact Substation shall be complete with the internal interconnections & Earthing (GI) and extending of earth bar of Neutral and body terminals to the frame of the Compact Substation for connecting to the earth pits.
-
-
-
... More
(g) The bidder shall assemble the Compact substation at factory and no assembly of the same shall be allowed at site. Bidder shall be responsible for Installation & commissioning Compact substation. Technical data sheet of the Transformer, HV / LV Switchgear, Relay etc. shall be submitted for approval of GE before placing the supply order.
(h) The equipments should be SCADA compatible (j) The bidder shall supply suitable & required no. of HT & LT Cable termination kits along with Compact Substation for HT & LT Cable terminations.
(k) The Design for Internal Arc Fault shall be tested for 20 kA for 1 Second as per IEC 1330/62271-202.
(l) The Contractor shall make all necessary arrangements for pre-despatch inspection at manufacturer site before despatch of equipment and for pre-commissioning test by rep of Accepting Officer after after installation of equipment. The cost for the same is deemed to be included in quoted rate.. Routine tests shall be conducted and original test certificates shall be submitted at the time of Pre-Dispatch Inspection. (m) Commissioning Spares: Additional commissioning spares such as Digital Multifunction Meter – 1 Nos, Indication lamps – 3 Nos, Protection Relay – 1 Nos, Spring Charging Handles – 2 Nos and Panel Keys – 2 Nos shall be provided by the bidder. (n) Suppressors or other protection devices shall be provided, if required as per schedule of quantities, wherever the sub-station installation is likely to interfere during the operation with any other electric or electronic equipment.
(o) The rate is inclusive for cement concrete foundation all as per manufacturer's recommendations / design.
-
-
-
... More
Supply and installation of Ring main unit three way 11 kV, 630 A, 21 kA / 3 Sec, Extensible Ring Main Unit / Compact Switchgear with Copper Busbar, consisting of 630 A, two numbers (As incomer) fixed Manual/Motorised SF6 insulated Vacuum Circuit Breakers & One Numbers Fixed Manual/Motorised SF6 insulated Vacuum Circuit Breakers (As Outgoing) in SF6 Gas insulated sealed for life minimum 2 mm Thickness SS 441 stainless steel tank IP 67 degree of protection with Air Insulated Metering Module along with FRTU, One Number manometer shall be provided for outgoing feeders, One set of 100/1A, 2.5 VA, Class 1.0 for metering & One set of 100 / 1A, 2.5 VA, CL 5P 10 Current Transformers shall be provided, One number of Digital Multifunction Meter with RS 485 Port shall be provided for VCB Feeders, One Set of 11 kV / RT3 / 110 / RT3, Class 1.0, 20 kVA PT shall be provided in Metering Module. Vacuum Circuit Breakers shall be with self-powered micro processor based Numerial Over Current and Earth Fault Relay having Charged Open / Closing Mechanism, On / Off Indicators, Mechanical Operation Counters etc including cement concrete foundation as per OEM design etc all as specified and as directed (for tapping of supply from SMU sub-stn)
1
-
-
... More
Note:
(a) The Contractor shall submit GA drgs & technical specifications before placing order and make all necessary arrangements for pre-despatch inspection at manufacturer site before despatch of equipment and for pre-commissioning test by rep of Accepting Officer after installation of equipment. The cost for the same is deemed to be included in quoted rate. Routine tests shall be conducted and original test certificates shall be submitted at the time of pre-despatch inspection.
-
-
-
... More
Supply, installing, testing and commissioning of LT feeder pillar box factory made, out door type, double door, slopy canopy, fabricated out of 3.15mm thick CRCA sheet with angle iron frame made of 65x65x6mm at vertical corners & base of Panel board floor mounted, dust and vermine proof, suitable for Voltage 415 V, 3 Phase 4 wire weather proof, with IP-54 protection, with separate hinge door for each compartment with locking arrangement, with back door common openable (Screwed), grouted in PCC 1:2:4, type B1 complete including painting with two coats of epoxy powder paint over a coat of primer after under going a rigorous metal treatment process involving alkaline degreasing, descaling in dilute sulphuric acid or any other acid and phosphate and with Aluminium busbar (TPN) of 1000 A, rated with insulators , suitable double compression copper cable glands and including provn of the following:- Note: The panel shall be of similar CPRI type tested panel. The quoted rate deemed to be inclusive of necessary PCC foundation as per manufacturer's recommendations and as directed. (EV Point Panel)
1
-
-
... More
Incoming:
a) MCCB 4 Pole, 415 V of capacity 320-400 A, Adjustable type with microprocessor release, breaking capacity 36 KA (Ics=100%Icu) -1No
Outgoing:
a) MCCB 4 Pole, 415 V, Adjustable thermal and magnetic type, 125 A with breaking capacity 25 kA (Ics=100%Icu) - 05 Nos (for EV Point VTPN DBs-4 Nos + Spare -1 Nos b) Spare compartment for MCCB 4 Pole, 415 V, Adjustable thermal and magnetic type, 125 A with breaking capacity 25 kA (Ics=100%Icu) - 03 Nos (for future expansion)
c) Trivector cum Intelligent Panel meter to measure Voltage, current, frequency, power factor, kWh, etc with all connected CTs - 01 No
d) LED indicating lamps with colour Red, Yellow, Blue - 01 Set
-
-
-
... More
Supply, installing, testing and commissioning of LT feeder pillar box factory made, out door type, double door type, slopy canopy, fabricated out of 3.15mm thick CRCA sheet with angle iron frame made of 40x40x 6mm at vertical corners & base of Panel board floor mounted, dust and vermine proof, suitable for voltage 415 V 3 Phase 4 wire weather proof, with IP-54 protection, with separate hinge door for each compartment with locking arrangement, with back door common openable (Screwed), grouted in PCC (1:2:4) type B1 complete including painting with two coats of epoxy powder paint over a coat of primer after under going a rigorous metal treatment process involving alkaline degreasing, descaling in dilute sulphuric acid or any other acid and phosphate and with Aluminium busbar (TPN) of 200 Amp rated with insulators , suitable double compression copper cable glands and including provn of the following:- Note: The panel shall be of similar CPRI type tested panel (main distribution panel at CSS ). The quoted rate deemed to be inclusive of necessary CC foundation as per manufacturer's recommendations and as directed. (50 KVA DG Panel)
1
-
-
... More
Incoming:
a) MCCB 4 Pole, 415 V, Adjustable thermal and magnetic type, 80 Amps with breaking capacity 16 kA (Ics=100%Icu) - 01 Nos Outgoing:
a) MCCB 4 Pole, 415 V, Adjustable thermal and magnetic type, 32 Amps with breaking capacity 16 kA (Ics=100%Icu) - 06 Nos (Lift- 02 No, Terrace pump-1Nos, Street light-1No, & 02 Spare)
b) Street light timer switch 3 Phase (01 Nos)
c) Intelligent Panel meter to measure voltage, current, frequency, power factor, kWH, etc with all connected CTs d) LED indicating lamps with colour Red, Yellow, Blue - 01 Set
-
-
-
... More
Supply, install, testing and commissioning Automatic power factor correction (APFC) Panel outdoor type (double door), slopy canopy, IP-54, made out of 3.15 mm CRCA sheet outer body, partitions with 2mm thick CRCA sheet, for 3 Phase 415 V & 50 Hz system with MD-XL capacitor and with suitable rated FP MCCB of 35 kA rupturing capacity as incomer for the following capacities duly controlled by auto and manual option with free standing configuration relay , auxilliary contacts , CTS , indicator lamps etc and necessary wiring complete and meter eqpt including necessary PCC 1:3:6 type C2 using 40 mm graded aggregate foundation for fixing / installing the panel on floor etc complete along with a) Power factor Controller minimum 12 stage and power factor meter - 01 No b) Ammeter - 01 No, Volt meter 0 - 500V - 01 No, with selector switch, including provn of suitable rated CTs in Main incoming panels & control wiring / flexible copper conductor cable for connecting APFC panel to Main incoming panel etc complete all as speciifed and dierected of capacity 200 kVAR with min 10 steps (2x50+ 3x25+5x5) including base frame/angle iron supports of suitable size and PCC foundation etc complete as per manufacturer's recommendations all as specified and directed.
1
-
-
... More
Supply, laying, testing & commissioning of HT UG cable, XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable(heavy duty) with stranded aluminium conductor,6.35/11 KV grade (Earthed system cable), of size 3 core 240 sqmm. Note:- (a)Earth work, sand cushioning, concrete cable covers,GI pipe protection for road crossings, HT termination joints will be measured and paid separately.
120
-
-
... More
M&L for cable jointing kit for 11 kV grade cable for in door end termination, heat shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 3 core 240 sqmm.
2
-
-
... More
Supply, laying and testing of LT UG cable, XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of 4 core 10 Sqmm size complete all as specified and directed. Note:- (a) Earth work, sand cushioning, concrete cable covers, GI pipe protection for road crossings will be measured and paid separately.
450
-
-
... More
Supply, laying and testing of LT UG cable, XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 V grade with stranded aluminium conductor of 4 core 16 Sqmm size complete all as specified and directed. Note:- (a) Earth work, sand cushioning, concrete cable covers, GI pipe protection for road crossings will be measured and paid separately. (Item caters for Fire Fighting system's siren also)
380
-
-
... More
Supply, laying and testing of LT UG cable, XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 V grade with stranded aluminium conductor of 4 core 25 Sqmm size complete all as specified and directed. Note:- (a) Earth work, sand cushioning, concrete cable covers, GI pipe protection for road crossings will be measured and paid separately.
200
-
-
... More
Supply, laying and testing of LT UG cable, XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 V grade with stranded aluminium conductor of 3.5 core 35 Sqmm size complete all as specified and directed. Note:- (a) Earth work, sand cushioning, concrete cable covers,GI pipe protection for road crossings will be measured and paid separately.
120
-
-
... More
Supply, laying and testing of LT UG cable, XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 V grade with stranded aluminium conductor of 3.5 core 95 Sqmm size complete all as specified and directed. Note:- (a) Earth work, sand cushioning, concrete cable covers,GI pipe protection for road crossings will be measured and paid separately.
380
-
-
... More
Supply, laying and testing of LT UG cable, XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 V grade with stranded aluminium conductor of 3.5 core 300 Sqmm size complete all as specified and directed. Note:- (a) Earth work, sand cushioning, concrete cable covers, GI pipe protection for road crossings will be measured and paid separately.
100
-
-
... More
M&L for Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and directed..
80
-
-
... More
S&F LED street light fittings on steel tubular poles of height not exceeding 7.5 m, comprising of epoxy powder coated housing, enclosed with glass cover in frame, (with total lumen output not less than 7200 lumens for efficiency not less than 100 lumens/Watt, CRI80, PF0.9, warm white type, minimum capacity 70 W with ingress protection IP 65/66 and SPD of capacity 10 kV etc including 40 mm dia medium grade GI pipe min 1.20 m length, bent to 120 degree shape with bracket and necessary GI clamps, nut bolts etc and connected with 1.5 Sqmm 3.5 core PVC flexible copper cable from junction box to fitting complete and testing on completion all as specified and as directed
10
-
-
... More
Supply, fixing, testing & commissioning of Loop in loop out box (minimum size 200x160x98 mm) FRP made with IP 65 protection of thermoplasic circuit breaker boxes with metric knock outs for cable entry and exit, Combi climate Cable Glands of IP 66/ IP 67 for cable entry and Grommets IP 65 for conduit for cable exit with MCB 6 A, 10 kA, C Curve Overload and Short Circuit protection, terminals as bus terminals for cable with necessary fixing arrangemets and with cable glands, etc all as specified.
10
-
-
... More
Earthing
-
-
-
... More
M&L for earthing complete with galvanized steel earth plate electrode 600x600x6 mm buried directly in ground (Earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connecting with galvanized iron GI strip size 32X6mm by means of bolt nut, check nuts and washers of galvanized iron and provision of GI tubing medium grade (ISI marked)of size 40mm for protection of GI earth strip, 20mm dia GI watering pipe with funnel and wire mesh including PCC pit 1:3:6 with pit cover of size 30x30 cm made of RCC 1:3:6 with 8 mm dia bars & with 6 mm dia size MS handle, angle iron frame made of angle iron of size 40x40x4 mm, adequate qty of charcoal dust and salt layers all around the earth plate, earth work in any type of soil, removal of excavated soil and returning filling in all as required at site complete all as specified in plate No 3 of SSR Part-I and all as specified or indicated including testing on completion. Note :-Rates inclusive of necessary excavation in any type of soil, earth work, PCC pit, CI cover, funnel with watering pipe, suitable size of light grade GI Protection pipe for earth strip in ground, earth strip upto 7.5 m long for connecting to test point etc. all as required at site for complete earthing).
43
-
-
... More
M&L for earthing complete with copper Earth Plate Electrode 600x600x3.15 mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of Plate not less than 1.50 m below normal ground level connected to 20x3mm copper strip (Earth Lead) and GI pipe 32 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the Plate by means of GI Bolts & Nuts complete all as per Electrical Plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC (1:2:4, Type B1) Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. complete all as specified. NOTE :-Rates inclusive of necessary excavation in any type of soil, earth work, PCC pit, CI cover, funnel with watering pipe, suitable size of light grade GI Protection pipe for earth strip in ground,earth strip upto 7.5 m long for connecting to test point etc. all as required at site for complete earthing).
10
-
-
... More
M&L for earthing complete with Galvanised Steel Earth Plate Electrode 600x600x6 mm burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of Plate not less than 1.50 m below normal ground level connected to 4mm dia GI wire (Earth Lead) and GI pipe 15 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the Plate by means of GI Bolts & Nuts complete all as per Electrical Plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC (1:2:4, Type B1) Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40x40x6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. complete all as specified
2
-
-
... More
Fire fighting/ Fire Alarm and Detection System
-
-
-
... More
Supplying, Installing, Commissioning and Testing of CPRI Prototype tested, Factory made, Free Standing Floor Mounted, Dust and Vermin proof PLC controlled panel board (Main), Compartmentalised, Outdoor type, fabricated with 3.15mm thick CRCA Sheet and shall be given pre-treatment for degreasing, phosphatising etc. in seven tank process and shall be powder coated with RAL7035 coat with matt finish after due preparation of surfaces. The panel shall consist of 300 A rating TPN bus bars of high conductivity Aluminium Alloy and shall be provided with colour coded heat shrinkable sleeves mounted on porcelain insulator supports, suitable double Compression Copper Cable Glands and panel shall be provided with separate compartments for each switch, with gland plates, lifting hooks, shutter type ventilating louver at both top & bottom duly internally secured with wire mesh, with suitable internal wiring with copper cable of suitable size, including instrumentation such as Ampere Meter, Volt Meter, Phase Indicating LED Lamps (RYB), Selector Switches etc with double stud hinged door, front openable with locking arrangement including interlocking with switch gears and suitable for 1100 Volts Grade, 3 Phase, 415 Volts, 4 Wire, 50 Hz, AC Supply and degree of protection shall be IP 54. The panel shall be fixed with angle iron frame made of angles of size 50x50x6mm at Corners and ISMC of suitable size for base, embedded 600 mm below ground level in PCC 1:2:4, Type B–1 using 20mm grade stone aggregate, 600 mm above ground level complete including connecting up with existing incoming and outgoing cables etc. and comprising the following:
1
-
-
... More
(Incoming)
(a) MCCB, 160-200 A, 4 Pole, 35 kA, 415 V, 3 Phase, AC, 50 Hz, Adjustable type complete with Overload Protection, No-Volt thermal based release – 1 Nos
(Outgoing)
(b) MCCB, 125-160 A, 3 Pole, 16 kA, 415 V, 3 Phase, AC, 50 Hz, Adjustable type complete with Overload Protection, No-Volt thermal based release –02 Nos.
(c) MCCB, 32-40 A, 3 Pole, 16 kA, 415 V, 3 Phase, AC, 50 Hz, Adjustable type complete with Overload Protection, No-Volt thermal based release –02 Nos.
(d) Star delta starter suitable for electric driven fire fighting pump 01 No & Star delta starter for jockey pump - 01 No.
(e) Auto/ Manual start provision with indications.
(f) LED Voltmeter & Ammeter of suitable capacities with selector switches & CTs.
-
-
-
... More
S&F LED EXIT sign/light double sided with battery back up for min 2 hrs complete with all accessories as directed.
10
-
-
... More
Supply and install Fire Extinguisher CO2 Type light weight squeeze grip type confirming to IS:15683 of capacity 4.5 kg all as specified and directed. Note: (i) Fire extsinguisher should equiped with hose of appropriate size and open-close should be with the help of wheel type valve. (ii) Fixing arrangement to wall will be included in the quoted rates.
31
-
-
... More
supply and install Fire Extinguisher ABC Type light weight squeeze grip type confirming to IS:15683 of capacity 6.0 kg all as specified and directed. Note: (i) Fire extiguisher should equipped with hose of appropriate size and open-close should be with the help of wheel type valve. (ii) Fixing arrangement to wall will be included in the quoted rates.
31
-
-
... More
Supply and install Fire Extinguisher Mechanical Foam Type light weight squeeze grip type confirming to IS: 15683 of capacity 9.0 kg all as specified and directed. Note: (i) Fire extinguisher should equiped with hose of appropriate size and open-close should be with the help of wheel type valve. (ii) Fixing arrangement to wall will be included in the quoted rates. (iii) Appropriate size of sign board should be hanged from wall/roof near all fire pints.
62
-
-
... More
S&F control panel wall mounted for Booster pump including of relays and starter of 12.5 HP for automatic operation of pump with the help of pressure switch including indication lamps, necessary control connections all as specified and as directed.
1
-
-
... More
S&F PVC insulated armoured Cable PVC sheathed LT 1100 V grade with copper conductor of size 2 core 1.5 sqmm multi stranded as per IS:1554 fixed to wall/roof/ false ceiling/ under floors complete all as specified and as directed.
640
-
-
... More
LIGHTENING PROTECTION
-
-
-
... More
S&F test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos. 8mm dia 25mm long hexagonal head screws including provision of 30x25x8 cm sheet metal box made out of 3.15 m thick CRCA sheet with front hinged door shutter & locking arrangement and duly painted with two coats of synthetic enamelled paint over a coat of red oxide primer complete all as specified and directed.
60
-
-
... More
Lift
-
-
-
... More
Design, supply, install, test & commissioning passengers lift, speed 1.5 m/sec, lift with single speed motor 415 V, 3 phase, AC 50 Hz supply conforming to IS- 14665, suitable to serve G + 04 upper floors to carry 08 passenger (554 kgs) with AC Variable Voltage & Variable Frequency drive (VVVF drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendant, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, automatic rescue device (ARD) system, 3D infra red sensor in full height of door & built in announcing system without hand set (03 Nos, one each in car, Machine room & near Ground floor landing door) complete all as specified in all respects duly checked and vetted by OEM approved by MES, complying the requirements stipulated in, relevant BIS Codes and NBC 2016 and shall satisfy the following features.
2
-
-
... More
The Lift operation control panel shall have the following information/control features mentioned below :
(a) Status – Normal/Maintenance/ Fireman operation
(b) Direction of travel
(c) Status of door – open/close
(d) Car position
(e) Passenger trapped alarm/intercom status
(f) Bring the lift down to desired floor in case of emergency/VIP movements.
-
-
-
... More
The elevators shall conform the following IS standards including their latest amendments or their approved equivalent US/BS/ISO :-
i) IS 15785: Installation and maintenance of lift without conventional machine rooms-code of practice.
ii) IS 14665 : 2000 Electric Traction Lifts (Part 1: Outline Dimensions, Part 2 : Code of practice for installation, Operation and maintenance, Part 3: Sec 1 Safety Rules: Passenger and Goods Lifts, Part 4 : Sec 1-Components and Part 5 : Inspection Manual)
iii) IS 2365:1977 Steel wire suspension rope for lifts and hoists
iv) IS 8216:1976 Guide for inspection of lift Wire Ropes
v) IS 4289 Specification for flexible Cables for lifts and other flexible connections (Part 1 : 1984 Elastomer insulation cables and Part 2 : 2000 PVC Insulated Circular Cables)
vi) National Building Code – 2016 Volume 2, Part 8 ,Section 5 A & 5B
-
-
-
... More
Aviation Light
-
-
-
... More
S&F aviation obstruction light LED type filament-less bulb with 10 W bulb including standard fixing arrangements complete all as specified and as directed
2
-
-
... More
S&F PVC insulated armoured Cable PVC sheathed LT 1100 Volts grade with copper conductor of size 3 core, 2.5 sqmm multi stranded conductor laid in ground/ fixed to wall/ roof etc., with suitable clamps, spacers, bolts, nuts etc., complete all as specified and as directed.
130
-
-
... More
S&F time switch 250 V, single Phase, 20 A rating with contactor fitted inside steel enclosure all as specified and directed.
1
-
-
... More
EV CHARGING POINT
-
-
-
... More
Supply, install, test and commissioning of compact reliable and robust DC fast charger capable for charging all types of Electric vehicle having DC Charger type Wall-Mounting, Input Volatge three-Phase, 5 Wire AC System, nominal input Voltage AC 400 V ± 15%, frequency 50-60 Hz, Ambient Temperature Range -25 to 55℃, Ambient Humidity 5 to 95%, Storage Temperature -40 to 70℃, IK10/IP55, Air Forced Cooled, Max. Volatge Output DC 200-1000 V with one Output, Maximum Output Current - 30 kW, Power Factor ≥ 0.99 (50% load above), Touch Screen display, Mobile Application or user interface/ QR Code / RFID Card/ Password Login, Metering Information in kWh, Communication Between Charger & Vehicle should be CAN Based Communication as per AIS 138, Communication between EVSE and CMS should be as per OCPP v 1.6 or above- 10/100 Base - T Ethernet (standard)/ Optional GSM Modem (4G) or Wireless, Protection and safety as per IEC 62196 2017, IEC 61851 2017, SAE J1772, CHAdeMO etc with Over Current, Under Voltage, Residual Current, Surge Protection, Leakage Protection, Short Circuit, Over Temperature etc complete of charger capacity not less than 30 kW confirmed to IS-17017 Part 1 to 3 complete all as specified and as directed.
8
-
-
... More
Supply, install, test and commissioning of compact reliable and robust AC fast charger capable of charging all types of Electric vehicle having AC Charger Wall - Mounting type, Input Volatge Single-Phase, nominal input Voltage AC 208 V ± 15%, frequency 50 Hz, Ambient Temperature Range -25 to 55℃, Ambient Humidity 5 to 95%, Storage Temperature -40 to 70℃, IK 10/IP 55, Touch Screen display, Mobile Application or user interface/ QR Code / RFID Card/ Password Login, Metering Information in kWh, Communication Between Charger & Vehicle should be CAN Based Communication as per AIS 138, Communication between EVSE and CMS should be as per OCPP v 2.0.1 or above- 10/100 Base - T Ethernet (standard)/ Optional GSM Modem (4G) or Wireless, Protection and safety as per IEC 62196 2017, IEC 61851 2017, SAE J1772, CHAdeMO etc with Over Current, Under Voltage, Residual Current, Surge Protection, Leakage Protection, Short Circuit, Over Temperature, etc., complete of charger capacity 3.3 kW confirmed to IS-17017 Part 1 to 3 complete all as specified and as directed.
20
-
-
... More
Note for the above EV point items :-
(a) The quoted rate deemed to be inclusive for necessary software, RFID cards, service & maintenance charges, data & communication charges etc complete during defect liability period of 2 years. EV charging point to be installed with complete system including Smart Pre-Paid meter of equivalent/suitable as per latest standards with OEM based software and server suitable for mobile/cell phone app operative. Necessary clearance from cyber security of HQ ENC (V) shall be obtained before execution.
(b)The Contractor shall submit complete technical specification and GA drgs for approval of GE before placement of order.
(c) Necessary copper cabling of suitable size with necessary controls, cable trays from VTPN DB to each EV charging stn is deemed to be included in quoted rate. VTPN DB will be measured and paid under Internal elec supply schedule.
(d) CMS/APP working, Internet (SIM to be provided by OEM/ Ethernet) charges are deemed to be included in the rate quoted by the contractor along with two years warranty from OEM, since the date of commissioning of EV charger.’
-
-
-
... More
Design, Supply, install, test and commisioning of car washing system consisting of electrically operated car washing hydarulic lift 4 Ton capacity (normal two post lift) with oil tank and platform, heavy duty air compressor 175 psi, 10.7 cfm, 3 HP with 220 ltrs capacity tank with motor complete with air discharge hose with nozzles, car washing pump of suitable capacity motor with 10 m hose and T type gun, heavy duty vaccum cleaner 70 ltrs two motors heavy duty including necessary PCC foundations, cables, control panels etc complete. Note:- The Contractor shall submit complete technical specification and GA drgs for approval of GE before placing the order.
1
-
-
... More
S&F Copper strip of size 20x3.15 mm with saddles and fixing screws etc for roof/wall complete all as specified (for EV Stn)
150
-
-
... More
DG SET
-
-
-
... More
Supply, install, test and commissioning of minimum 50 kVA/40 kW DG set with alternator out put Voltage 415 Volts +/- 1% at set value of 415 V at a frequency 50 HZ +/- 0.5% with suitable standard control panel, NTP installing at Naval Dockyard, Visakhapatnam. The engine as per IS:10001/ 10002 and Alternator as per IS: 13364 , all mounted in sound proof canopy type acoustic enclosure and AMF panel as per manufacturers design and specification as per latest approved CPCB-02 norms confirming to the detailed specifications appended below :- (i) The capacity of Generator set shall be net after all due de-rating factors as per relevant ISI design
(ii) Rate quoted shall be deemed to be inclusive of cable and terminations form Generator to the AMF Panel, with necessary holes to wall including making good to disturbed surfaces so as to match with the existing finishes all as specified and directed.
(iii) The quoted rate shall be deemed to be inclusive of first fill of oil and final successful acceptance test
1
-
-
... More
(I) ENGINE
(a) General: Suitable four stroke compressed ignition, radiator water cooled, Turbo charged aspiration, continuous duty with 10% overload capacity for any one hour in 12 hours running, 50°C intake air temperature, CPCB-02 Euro emission engine developing minimum 76 BHP at 1500 RPM coupled to alternator mounted on Channel Iron base frame with in built fuel tank of minimum capacity suitable for 12 hrs continous running. The prime mover provided should be as per IS specifications.
(b) Air intake system : Should comprise of dry type intake air filter mounted on engine, one in number vacuum indicator mounted on intake piping.
(c) Exhaust System: Should comprise of one exhaust manifold, dry type, mounted on engine, one exhaust residential type silencer which should be positioned in such a way that the exhaust gas is not sucked by the fan on the radiator, thereby affecting the cooling system. The silencer should cater to the noise level tolerance prescribed in the relevant IS/BS. The silencer should be provided with flaps with a provision so that it will open only when the generator is running. The complete exhaust system shall be properly supported so that entire lot of the exhaust system shall not fall on the DG Set.
-
-
-
... More
(d) Fuel System: Should comprise of disposal type element fuel filter, pressure type fuel pump mounted on engine, non return check valve in fuel supply and drain lines, wire braided hose between filter and pump, fuel system with suitable capacity electronic governor and engine mounted actuator. The fuel tank must have proper locking arrangement with level indicator and to be integrated with base frame.
(e) Cooling System: Should comprise of radiator designed and tested for 50 degree Centigrade ambient temperature with 7 PSI pressure cap mounted on base rail. The thermostat installed in the engine coolant outlet, fresh water pump mounted on engine, fan and fan hub mounted on engine. A reservoir of 50% of radiator capacity to replenish coolant by gravity (as and when required) is also to be provided.
(f) Lubricating System: Should comprise of lubricating oil sump mounted on engine, gear driven lubricating oil pump mounted on engine, lubricating oil cooler-fresh water cooled integral with engine cool out circuit mounted on engine, oil filter lubricating with cap and lubricating oil dip stick for oil level check mounted on engine. The system should be capable of feeding lube oil to the main end & large end bearings, cam shaft, valve rocker gear and all moving parts.
(g) Starting System: Should comprise of suitable Voltage DC electrical starter mounted on engine, with suitable maintenance free batteries of capacity 12 V DC with suitable AH to be mounted in trays (having rubber insulation) on the main frame. It should have the provision to charge the battery from external sources during static condition and while running of the generator.
-
-
-
... More
(h) AC Generator : The generator shall be horizontal and foot mounted, 40 KVA, 415 Volts, 3 phase, 4 wire, 0.8 PF, 50 HZ, self excited, self regulated, brushless AC generator, suitable for an ambient temperature of 50° C with IP-23 enclosure class H insulation and temperature rise limited to class H as per following technical details :-
(i) Type, Brush less AC Generators
(ii) Output rating minimum 50 kVA
(iii) Output Voltage: 415 ± 1% under all loading conditions.
(iv) Output frequency 50 Hz ±0.5% up to 0.8 lagging.
(v) No of Phases: 3 phase with 01 Neutral (4 wire)
(vi) Mounting : Horizontal foot mounted.
(vii) Enclosure : Minimum IP-23 / Drip proof and screen protected.
(viii) Automatic Voltage regulator.
(ix) Class of insulation-'H'
NOTE : Following shall be deemed to be included in cost quoted :-
(i) Suitable size RCC cement concrete foundation platform of canopy base with height as required at site to mount the generator as per manufacturer's instructions/ recommendations. The cost of foundation bed incl earth work etc is deemed to be included in the quoted rate. (ii) Connecting cables , cables glands, cable lugs to new panel complete with all necessary accessories. (iii) Install on the foundation, connecting fuel lines, cable etc. (iv) Test and commissioning complete. (v) The cost of control cables from engine Control panel to AMF panel shall be deemed to be included in the cost quoted.
-
-
-
... More
(j) BASE FRAME: Shall be stand by and fabricated with CRCA sheet metal which shall be suitable to mount the engine, alternator and radiator, channel width of base frame shall be adequate to accommodate anti-vibration pads.
(k) CONTROL PANEL: Shall be indoor type manufactured with 14/16 guage CRCA sheet and is powder coated for weather-proff and long lasting finish consisting of microprocessor power command controller, Aluminium busbars with suitable capacity with incoming/outgoing terminals, indicating lamps for 'Load ON' and 'Set Running', instrument fuses duly wired and ferruled, MCCB of suitable rating with overload and short circuit protections etc. complete all as specified and directed.
(l) AMF PANEL: Shall be indoor LT 415 Volts 3 phase 50 Hz, Floor mounted sheet steel enclosed cubical type panel made out of minimum 1.6 mm thick CRCA sheet for body & partitions ,consisting of suitable rated four poles contactors, MCCB- 2 Nos (for Mains/DG ), AMF Relay, Volt meter, ammeter with selector switches, CTs and 3 Phase indicating lamps, timers etc all as per latest engineering practices.
(m) Accessories :-
(i) 01 No standard mechanical and electrical tool box.
(ii) Internal covered tube lights.
-
-
-
... More
(n) Acoustic Enclosure :-
Specially designed to meet CPCB norms 75 dBA @ 1 m at 75% load under free field conditions. The Acoustic enclosure is made of CRCA sheets and a structural/sheet metal base with high quality noise absorbent and fire-retardant grade acoustic insulation material (PU Foam) complying to IS 8183 with two point lifting handles
(a) Internal Lighting: Tube lights with protective mesh around it to be fitted inside the container for proper illumination
(b) Doors : The enclosure will be provided with suitable doors on the side and rear to enter the enclosure during operation and maintenance. All doors will be provided with lock and handles for opening/ closing the doors, retainers for holding the panel door
(p) Painting Scheme
ISS shade 220 olive green 1994 or all as per manufacturers specifications
(q) Lifting/ Transportation arrangements :-
Container with suitable corners will be provided to lift the DG set along with container. This is suitable for road/ rail/ sea transportation.
-
-
-
... More
(r) Trials:-
Trials on site should be given as per load tests prescribed and all functional trials should be shown.
Note: (i) The Engine, alternator, Control Panel, Acoustic enclosure shall be integrated unit sourced from OEM only as per Make given in Sch 'A'.
(ii) AMF Panel shall be integreted inside acoustic panel as directed by Engr-in-Charge. (iii) Testing of DG set shall carried by representative of AO. The cost of POL & resistive load bank required for testing the DG Set is deemed to be included in quoted rates. The DG Set shall run for a period of 12 hours continuosly out of which 15 minutes on No Load , 2 Hrs 15 minutes of 25% rated load, 2 hrs on 50% rated load, 2 Hrs 30 minutes on 75 % rated load, 4 Hrs on rated full load, 1 hrs on 110% rated full load. (iv) First filling of Engine Oil and fuel etc should be arranged by contractor for complete testing.
-
-
-
... More
PILE FOUNDATION
-
-
-
... More
Boring for bored cast–in–situ piles 600mm dia in any type of soil/Soft disintegrated rock except hard rock and getting out and disposal of soil outside MoD land using Rotary drilling method by Hydraulic Rotary Rig by DMC method complete all as specified and directed.
6496
-
-
... More
Boring for bored cast–in–situ piles 600mm dia in hard rock and getting out and disposal of soil outside MoD land using Rotary drilling method by Hydraulic Rotary Rig by DMC method complete all as specified and directed.
812
-
-
... More
Carrying out initial load test on 600mm dia pile as per IS 2911 Part IV,complete all as specified and directed.
2
-
-
... More
Carrying out routine load test on 600mm dia pile as per IS 2911 Part IV,complete all as specified and directed.
4
-
-
... More
Carrying out low strain integrity test on bored cast in situ piles including analysing the result as per ASTM D 5882 and as directed.
406
-
-
... More
Carrying out lateral load test on cast in situ piles 600 mm dia piles as specified in IS and directed.
2
-
-
... More
Carrying out pull out test on cast on situ piles 600 mm dia pile as per specified in IS ,complete all as specified and directed.
2
-
-
... More
Carrying out vertical load test on cast on situ piles 600mm dia pile as per specified in IS ,complete all as specified and directed.
4
-
-
... More
Chipping out pile up to cut off level including disposal up to a distance of 50 m all as specified and directed.
111.98
-
-
... More
SCHEDULE 'A' PART-XV
PHASE -II : COMPREHENSIVE MAINTENANCE OF LIFTS OF 8 PASSENGERS AS PROVIDED UNDER SERIAL ITEM No.92 to 95 ABOVE AND WORK WILL COMMENCE AFTER EXPIRY OF DEFECTS LIABILITY PERIOD OF 03 YRS FROM DATE OF COMPLETION OF WORK UNDER PHASE I
-
-
-
... More
Comprehensive maintenance of Electrically Operated 8 passenger lift, 2 Nos (each 544 Kgs) to serve G+4 upper floors all as mentioned vide SI No. 92 to 95 of BOQ during 1st year and after expiry of defects liability period all as specified and directed
12
-
-
... More
SCHEDULE 'A' PART-XVI
PHASE - III: SECOND YEAR COMPREHENSIVE MAINTENANCE OF LIFTS OF 8 PASSENGERS AS PROVIDED UNDER SERIAL ITEM No. 92 to 95 ABOVE AND WORK WILL COMMENCE AFTER COMPLETION OF FIRST YEAR COMPREHENSIVE MAINTENANCE UNDER PHASE II.
-
-
-
... More
Comprehensive maintenance of Electrically Operated 8 passenger lift, 2 Nos (each 544 Kgs) to serve G+4 upper floors all as mentioned vide SI No. 92 to 95 of BOQ for second year and after completion of first year Comprehensive Maintenance.
12
-
-
... More
SCHEDULE 'A' PART-XVII
PHASE -IV: THIRD YEAR COMPREHENSIVE MAINTENANCE OF LIFTS OF 8 PASSENGERS AS PROVIDED UNDER SERIAL ITEM No. 92 to 95 ABOVE AND WORK WILL COMMENCE AFTER COMPLETION OF 2ND YEAR COMPREHENSIVE MAINTENANCE UNDER PHASE III.
-
-
-
... More
Comprehensive maintenance of Electrically Operated 8 passenger lift, 2 Nos (each 544 Kgs) to serve G+4 upper floors all as mentioned vide SI Nos. 92 to 95 of BOQ for third year and after completion of second year Comprehensive Maintenance.
12
-
-
... More
Note for SI No: 124 to 129:-
(i) Comprehensive maintenance consists of preventive and breakdown services including replacement of material and labour for major/minor spare parts and consumables like topping of Oils/grease/door rollers/relays/door belts/gate lock contacts and hardware like bolts and nuts including load testing of lift for satisfactory performance once in a year complete and rate quoted by the tenderer includes for the above Lifts.
(ii) Preventive maintenance consists of carrying out routine check by skilled personnel as specified in Particular specifications and as directed by Engineer-in-Charge and lubricating to all moving parts, topping parts, topping up of oils as per Lubrication Chart including Material and labour for all consumable and major/minor spare parts.
(iii) Breakdown maintenance consists of attending to the faults that may occur and carrying out necessary repairs to electrical, control circuits and mechanical components including materials & labour for all minor & major spare parts and consumables of the lift that may occur during the operation.
(iv) Monthly, Fortnightly, quarterly maintenance registers shall be maintained and signed by the site engineer and contractor.
(v) Load testing shall be arranged by the contractor to the Lift for which repairs were carried out as and when directed by Engr -in-Charge.
(vi) All maintenance works shall be carried out by well qualified tradesmen and supervisor of OEM.
-
-
-
... More
(vii) The quoted rate shall be deemed to be included the above aspect and for consumables such as timely toping up oils, acrylic covers, fuses, grease, waste cotton, stationery and other miscellaneous items and all minor & major spare parts. (viii) The tenderer shall submit MoU from the original manufacturer of the lift for comprehensive maintenance to undertake comprehensive maintenance during and after Defects Liability Period directly or through their nearest authorized/ accredited agencies service personel. The MoU shall be submitted at least 06 months prior to issue of completion certificate of main contract as per Work Order No I. (ix) In case of any of the lift/lifts is/are not working for more than 24 hours but less than 10 days, Recovery will be affected at the rate of Rs 2,000/- per lift per day and Rs 3,000/- per lift per day after 10 days. (x) Contractor must change the out sourcing employees every eleven months for comprehensive maintenance of lifts. This has to be ensured by GE & AGE during execution.
-
-
-