Military Engineer Services Tender
To know what Andhra Pradesh government has posted about any AP etender, Bidassist helps us to get a one-stop platform where a registered bidder can have access to the details on each and every eprocurement tender. There is no need to provide the details on the AP E-procurement website i.e. https://www.apeprocurement.gov.in as BidAssist helps us find the specific etender we're looking for. BidAassist has collated each and every Eproc Andhra Pradesh Tender on its website.
Military Engineer Services - MES Tender
Civil And Construction
Building Construction
Eprocure
Opening Date4 Jun 2024
Closing Date3 Sep 2024
Tender Amount₹ 1,58,00,000
Costs
EMD
₹ 2,33,000Document Cost
₹ 1,000Tender Fee
Refer Documents
Summary
Provision Of Building And Allied Services Under Wp 20 At Naval Station Rambilli Near Visakhapatnam
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_657702_1Bid Award Id
ViewTender No
DDG CE V TOKEN 01 OF 2024 2025Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Lump sum amount worked out by the contractor for "INTERNAL WATER SUPPLY" as listed in Schedule 'A' Part-IV on Serial Page No.
1
-
13367.46
Lump sum amount worked out by the contractor for "INTERNAL ELECTRIFICATION" as listed in Schedule 'A' Part-V on Serial Page No.
1
-
598897.48
Lump sum amount worked out by the contractor for "EXTERNAL WATER SUPPLY" as listed in Schedule 'A' Part-VI on Serial Page No.
1
-
98833.56
Lump sum amount worked out by the contractor for "EXTERNAL ELECTRIFICATION" as listed in Schedule 'A' Part-VII on Serial Page No.
1
-
1328382.04
Lump sum amount worked out by the contractor for "PATH/ HARDSTANDING" as listed in Schedule 'A' Part-VIII on Serial Page No.
1
-
989305.8
Lump sum amount worked out by the contractor for "AREA DRAINAGE" as listed in Schedule 'A' Part-IX on Serial Page No.
1
-
552719.95
Lump sum amount worked out by the contractor for "SEWAGE DISPOSAL" as listed in Schedule 'A' Part-X on Serial Page No.
1
-
89390.33
Lump sum amount worked out by the contractor for "FIRE DETECTION AND FIRE ALARM SYSTEM" as listed in Schedule 'A' Part-XI on Serial Page No.
1
-
513586
Lump sum amount worked out by the contractor for "LIGHTNING PROTECTION" as listed in Schedule 'A' Part-XII on Serial Page No.
1
-
31030
Lump sum amount worked out by the contractor for "AIR CONDITIONING" as listed in Schedule 'A' Part-XIII on Serial Page No.
1
-
437533.2
Schedule "A" Part - XIV: [Miscellaneous Items] [Internal Water Supply, Internal Electrification, External Water Supply, External Electrification, Lightning Protection, Fire Detection and Fire alarm System and Air Conditioning]: [To be quoted by the bidder.]
-
-
-
M&L for Point wiring with 1.5 Sq.mm FRLSH PVC insulated unsheathed copper conductor cable, single core multi stranded 1100Volt grade confirming to IS 694: 1977, drawn in and including rigid PVC conduit not less than 20mm bore, concealed type, medium grade as per IS 9537 (Part 1-1983) with conduit accessories, junction boxes, tees, terminal boxes with and including factory made MS boxes, modular cover plates with frame for mounting modular switches, including one run of 1.5 Sq.mm single core FRLS PVC unsheathed copper conductor cable as earth continuity conductor and connected to common earth dolly, for one light / fan point controlled by one one way switch, complete all as specified and as directed. Note: Cutting chases and making good surfaces shall be included in the unit rate.
51
-
-
Description all as per Serial Item No. 15 here-in-before but with 4.0Sqmm copper conductor cable and 4.0Sqmm cable as earth continuity conductor for 3 pin 5/15Amp switch socket point, on independent board, complete all as specified.
187
-
-
S&F Modular type Data socket white glossy RJ 45 and RJ 11 Port with suitable gang box and face, complete all as specified and directed.
88
-
-
M&L for Earthing complete with galvanised steel earth plate electrode 60cm X 60cm X 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead 4mm GI wire by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No.3 of SSR Part-I, including excavation / earth work in any strata, adequate quantity of charcoal and common salt, PCC chamber with with RCC 1:2:4 type B1 40mm thick cover slab with suitable handle and angle iron frame of suitable size to fix the cover, with 20mm bore GI pipe light grade for watering with funnel, wire mesh and 15mm bore GI pipe medium grade for GI wire protection and 4mm GI earth wire, including testing after completion, complete all as specified and directed. Note : Earth wire will be measured after 7.5mtr from the earth strip or earth testing terminal block whichever is lesser under relevant item.
4
-
-
All as per Serial Item No. 18 here in before but using galvanised iron strip 32 x 6mm earthing lead and 50mm bore GI pipe medium grade as protection pipe. .
14
-
-
Supply, laying, testing and commissioning of LT XLPE insulated, screened with extruded PVC inner sheathed, PVC bedded, galvanised steel strip armoured electric FR power cable [heavy duty] of size 4core x 10Sqmm, suitable for earthed system with stranded copper conductor, 1100 volts grade, with and including cable glands, ferrules and connected accessories, laid in trenches or ducts or through the pipe etc., complete all as specified and as directed.
250
-
-
All as per Serial Item No. 20 here-in-before but for cable of size 10core x 2.50Sqmm.
30
-
-
All as per Serial Item No. 20 here-in-before but for cable of size 2core x 6Sqmm.
100
-
-
All as per Serial Item No. 20 here-in-before but for cable of size 4core x 6Sqmm.
18
-
-
All as per Serial Item No. 20 here-in-before but for cable of size 2core x 10Sqmm.
30
-
-
Supply, laying, testing and commissioning of Fully Touch Screen Repeater alarm for fire detection and alarm system at security office through GSM/GPRS complete with necessary wiring, data transmission through LAN/GPRS along with SCADA software, communication through cloud, complete all as specified and as directed.
1
-
-
S&F GSM/PSTN auto dialler along with activated SIM, complete all as specified and as directed.
1
-
-
S&F Voltage stabilizer of capacity 5KVA, for automatic operation, suitable for deep freezers / refrigerator / water cooler / 2 Ton AC, single phase naturally air cooled indoor type and designed for input variation 170V to 270V, output voltage stabilized at 230Volt with accuracy of ± 2.50%, complete all as specified and as directed.
8
-
-
M&L for PVC insulated, PVC sheathed electric control cable galvanized steel strip or wire armoured, multistranded copper conductor cable of size 2 core x 2.5 sqmm, Heavy duty, 1100 Volts, FRLS Grade, ISI marked with all accessories, drawn in and including rigid PVC conduit not less than 20mm bore, concealed type, medium grade as per IS 9537 (Part 1-1983) with conduit accessories, junction boxes, tees, terminal boxes, complete all as specified. Note: One run of cable and one run of conduit shall be measured as one unit.
40
-
-
M&L for PVC insulated, PVC sheathed electric control cable galvanized steel strip or wire armoured, multistranded copper conductor cable of size 2 core x 1.5 sqmm, Heavy duty, 1100 Volts, FRLS Grade, ISI marked with all accessories, drawn in and including rigid PVC conduit not less than 20mm bore, concealed type, medium grade as per IS 9537 (Part 1-1983) with conduit accessories, junction boxes, tees, terminal boxes, complete all as specified. Note: One run of cable and one run of conduit shall be measured as one unit.
300
-
-
M&L for Valve chamber of size 1500mm x 1500mm x 1200mm internal dimensions, with and including excavation in any type of soil, spreading, levelling and refilling etc. PCC (1:4:8) type D2 for foundation, Fly ash brick work of one brick thick wall in CM (1:4) including internal plaster 15mm thick in CM (1:4) external plaster 15mm thick(1:4) upto 150mm below GL and providing coping in PCC (1;2:4) type B1, angular iron frame of size 50x50x6mm with 6mm thick MS plate cover complete including locking arrangements and having FRP coating of 2mm thick on both inside and outside surfaces, complete all as specified and shown in TD drawing.
2
-
-
Supply, laying, testing and commissioning of Ductile Iron pressure pipe of 100mm bore with socket and spigot ends with blast furnace sludge cement with Portland cement properties suitable for push -on-jointing with inside cement mortor lining with internal metallic zinc coating and external black bitumen coating duly ISI marked, confirming to IS-8329:2000, class K-9, PN-10 rating, laid in trenches / floor, complete all as specified and as directed. Note: 1. Necessary earth work will be measured and paid separately. 2. Necessary fittings will be measured and paid separately.
300
-
-
Supply, laying, testing and commissioning of Ductile Iron pressure pipe of 80mm bore with socket and spigot ends with blast furnace sludge cement with Portland cement properties suitable for push -on-jointing with inside cement mortor lining with internal metallic zinc coating and external black bitumen coating duly ISI marked, confirming to IS-8329:2000, class K-9, PN-10 rating, laid in trenches / floor, complete all as specified and as directed. Note: 1. Necessary earth work will be measured and paid separately. 2. Necessary fittings will be measured and paid separately.
30
-
-
M&L for DI Specials such as Bends , tapers any type, Tee pieces, single branch, "Y" junction, double branch, cross, collars, caps and plugs for connecting up to 150mm bore DI Pipe all as per IS:9523, complete all as specified and as directed. Note: Fittings shall be conforming to IS 9523:2000.
150
-
-
Supply, Installationing, testing and commissioning of LT panel Indoor type, OEM factory made totally type tested panel confirming to IEC 61439 Part-1 & 2, confirming to IP 54 Protection, free standing mounted on PCC pedestal, dust and vermin proof, fabricated with 2.00mm thick CRCA sheet painted with seven tank process and shall be powder coated with RAL7035 coat with matt finish, high conductivity aluminium alloy bus bar TPN of rating 1.5 times the incoming switchgear Amps capacity with colour coded heat shrinkable sleeves mounted on porcelain insulator supports with separate hinge door for each compartment with operating handle & locking arrangement with back door common openable (screwed/Lockable) including interlocking with switch gears and suitable for 1100 volts Grade, 3 phase 4 wire with rated operational voltage 433V,50Hz, AC supply and to with stand short circuit fault level of not less than 100KA, rated insulation voltage of 1000V and Impulse withstand of 12kV and minimum internal Arc with-stand of 65kA, 500mSec as per IEC 61641, weather proof, fixed with angle iron frame 50x50x6mm at corners and ISMC at base, fixing with PCC 1:2:4 type B1, all as per the OEM recommendation and connecting of incoming/outgoing cable etc., complete with and including following accessories:- Note: All Incoming MCCBs are of Microprocessor based and out going MCCBs are of Adjustable type. Incoming: (a) MCCB 315Amp, 4Pole, 50kA with - 02 Nos Outgoing: (a) MCCB 200Amp, 4Pole, 36kA with microprocessor release - 06 No (b) MCCB 63Amp, 4Pole, 16kA with microprocessor release - 09 Nos (c) MCCB 25Amp, 3Pole, 16kA with microprocessor release - 01 Nos (d) Digitial Ammeter 0-4000Amps with CTs & selector switch - 01 No (e) Digitial Voltmeter 0-500Volts with selector switch - 01 No (f) LED Indicating lamps RYB with bakelite fuse cut outs - 01(Set of Three)
1
-
-
All as per Serial Item No. 34 here in before but for following accessories:- Incoming: (a) MCCB 63Amp, 4Pole, 16kA with with microprocessor release - 01 Nos Outgoing: (a) MCCB 40Amp, 4Pole, 16kA with microprocessor release - 01 No (b) MCCB 25Amp, 4Pole, 16kA with microprocessor release - 02 Nos (c) Digitial Ammeter 0-4000Amps with CTs & selector switch - 01 No (d) Digitial Voltmeter 0-500Volts with selector switch - 01 No (e) LED Indicating lamps RYB with bakelite fuse cut outs - 01(Set of Three)
1
-
-
All as per Serial Item No. 34 here in before but for following accessories:- Incoming: (a) RCCB 40Amp, 4Pole - 01 Nos Outgoing: (a) MCB 32Amp, TPN, 10kA, B curve - 05 No (b) Digitial Ammeter 0-3000Amps with CTs & selector switch - 01 No (c) Digitial Voltmeter 0-500Volts with selector switch - 01 No (d) LED Indicating lamps RYB with bakelite fuse cut outs - 01(Set of Three)
1
-
-
M&L for Cutting & Chipping of laitance concrete in piles above cut off level upto a maximum of 1m from cut off level and disposal to distance of 10KM and depositing where directed by Engineer-in-Charge.
5
-
-
M&L for Drilling or boring for 450mm nominal dia. bored cast-in-situ piles through any or all types of strata i.e soft/loose soil, stiff clay, gravel, cobble stone, compact moorum, soft conglomerate or loose boulders, disintegrated rock, weathered rocks/rocks etc., (except hard rock for socketing depth) upto top of socketing depth/founding depth by adopting suitable method with perennial water and disposal of drilling/bored materials outside MD land as directed, complete all as specified and as directed.
616
-
-
All as per Serial Item No. 38 here in before but for 450mm nominal dia through hard rock for founding depth minimum 2D (Where D is dia of pile), complete all as specified. Notes for Item Nos. 38 & 39:-
(i) The depth of boring for piles shall be measured from existing ground level to the approved founding level. (ii) It shall be ensured that the waste bentonite slurry/ drilled or bored material is pumped off from the premises to locations shown by GE to contractor at his own cost. (iii) All channels/tanks made for bentonite circulations shall be filled with approved moorum obtained by contractor at his cost after clearing all bentonite cakes. (iv) The contractor may use any approved method as approved by GE for boring without any extra cost to the Govt. The rates for boring of piles shall be inclusive of any method/ casing that may be used by the contractor for bored piles. Nothing extra shall be paid. (v) For the purpose of payment of boring/drilling, description of hard rock shall be as given in SSR Part-I specification. (vi) The rate quoted by the contractor shall be inclusive of the rates for the shifting and setting up of piling rig as many times as required.
25
-
-
Carrying out routine load test on 450mm dia pile (working pile) as per standard procedure given in IS-2911 (Part IV) by high strain dynamic load with compressive strength, including construction of test cap, dismantling the cap after the test and clearing the site and maintaining complete records of load settlements etc and submission of reports for 1.5 times of the design load, complete all as specified and as directed.
1
-
-
Carrying out initial load tests on test pile of 450mm dia as per standard procedure laid down in IS-2911 by static load test method with compressive strength, including construction of test cap, dismantling the cap after the test and clearing the site and maintaining complete records of load settlements etc. as specified and as directed by GE and submission of reports for 2.5 times of the design load in non-working areas in the vicinity of site, including the cost of new piles with specification as same as working pile with minimum depth of socketing into the hard rock 2D (Where D is dia of pile) depth, complete all as specified. Note: Load rquired for testing as per IS shall be arranged by the contractor and test pile shall be abondoned after testing.
1
-
-