Military Engineer Services Tender
To know what Andhra Pradesh government has posted about any AP etender, Bidassist helps us to get a one-stop platform where a registered bidder can have access to the details on each and every eprocurement tender. There is no need to provide the details on the AP E-procurement website i.e. https://www.apeprocurement.gov.in as BidAssist helps us find the specific etender we're looking for. BidAassist has collated each and every Eproc Andhra Pradesh Tender on its website.
Military Engineer Services - MES Tender
Building Construction
Eprocure
Opening Date2 Jan 2025
Closing Date5 Feb 2025
Tender Amount₹ 18,80,00,000
Costs
EMD
₹ 15,00,000Document Cost
₹ 3,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_691459_1Tender No
85446Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Lumpsum price worked out by the contractor for "Internal Electrification", as listed in Schedule "A" Part – III .
1
805824
-
... More
Lumpsum price worked out by the contractor for "Internal Water Supply", as listed in Schedule "A" Part – IV .
1
625110
-
... More
Lumpsum price worked out by the contractor for "Sewage Disposal", as listed in Schedule "A" Part – V .
1
1284909
-
... More
Lumpsum price worked out by the contractor for "External Water Supply", as listed in Schedule "A" Part – VI
1
108337
-
... More
Lumpsum price worked out by the contractor for "External Electrification", as listed in Schedule "A" Part – VII
1
2081558
-
... More
Lumpsum price worked out by the contractor for Roads", as listed in Schedule "A" Part – VIII .
1
3737049
-
... More
Lumpsum price worked out by the contractor for "Area drainage", as listed in Schedule "A" Part – IX
1
1920260
-
... More
Lumpsum price worked out by the contractor for "DG set", as listed in Schedule "A" Part – X
1
95731
-
... More
Lumpsum price worked out by the contractor for "Fire fighting and fire alarm system", as listed in Schedule "A" Part – XI
1
793400
-
... More
Lumpsum price worked out by the contractor for "Retaining wall", as listed in Schedule "A" Part – XII
1
19725625
-
... More
Lumpsum price worked out by the contractor for "Lightning Protection", as listed in Schedule "A" Part – XIII
1
213694
-
... More
Lumpsum price worked out by the contractor for "PVC Conduit", as listed in Schedule "A" Part – XIV
1
33428
-
... More
Lumpsum price worked out by the contractor for "Lifts", as listed in Schedule "A" Part – XV
1
17466
-
... More
Lumpsum price worked out by the contractor for "Solar water heater", as listed in Schedule "A" Part – XV
1
187950
-
... More
Schedule "A" Part - XVI [Miscellaneous Items]
-
-
-
... More
Internal Electrification
-
-
-
... More
Point Wiring complete with 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, confirming to IS - 694 drawn through and including heavy duty PVC Conduit, 20 mm dia including all accessories concealed in Walls / Roofs / Floors / Ceiling etc. and Pressed Metal Flush Box made out of 2mm thick MS Sheet of suitable size and 3 mm thick Hylam Sheet top cover for fixing switches, fittings, regulators etc concealed in walls, including 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable as earth continuity conductor with colour coding and connecting to Earth Dolly for One Light / Fan Point / Bell Point controlled by One Switch complete all as specified.
691
-
-
... More
All as per Serial Item No. 17 above but One 3 Pin Switch Socket Outlet 5 Amps on Independent Board complete all as specified.
147
-
-
... More
All as per Serial Item No. 17 above but One 3 Pin Switch Socket Outlet 5 Amps on same Board complete all as specified.
209
-
-
... More
All as per item No.17 here-in-before but controlled by two two way switch complete all as specefied and directed.
16
-
-
... More
All as per Serial Item No. 17 above but one 3 Pin Switch Socket Outlet 16 Amps on independent board, with 1100 Volts, FRLS grade, 4.0 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable confirming to IS - 694 and including 1100 Volts, FRLS grade, 4.0 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable as Earth Continuity Conductor.
64
-
-
... More
Supply and fixing of ceiling fan complete with blades, down rod and other accessories, AC 230 Volts, 1200 mm sweep, min air delivary 210 CFM with service value 6.00, BEE, 5 star rated with brushless direct current motor [BLDC] including connecting with 1.0 Sqmm, 2 core copper conductor from ceiling rose complete all as specified and as directed.
113
-
-
... More
Supply and fixing exhaust fan, 250mm sweep, plastic body, heavy duty with louvers, AC single phase, 230 volts, connection with 1.0 sqmm copper conductor flexible wire from ceiling rose including making necessary opening and making good the disturbed surface complete all as specified and as directed.
50
-
-
... More
Supply and fixing exhaust fan, 300 mm sweep, metallic body, heavy duty , AC single phase, 230 volts , 5 star rating, connection with 1.0 sqmm copper conductor flexible wire from ceiling rose including making necessary opening and making good the disturbed surface complete all as specified and as directed.
16
-
-
... More
S&F energy efficient LED Tube light fitting with tube 5W or nearest size, 240 Volts, 50 Hz, surface mounted, decorative ultra slim square profile LED light fixture with extruded polycorbonate environmental friendly, energy efficient ready to use pack of complete mounting brackets including connecting up with 1.0 Sqmm 3 core flexible copper conductor cable complete all as specified as directed
48
-
-
... More
S&F energy efficient LED Tube light fitting with tube 10W or nearest size, 240 Volts, 50 Hz, surface mounted, decorative ultra slim square profile LED light fixture with extruded polycorbonate environmental friendly, energy efficient ready to use pack of complete mounting brackets including connecting up with 1.0 Sqmm 3 core flexible copper conductor cable complete all as specified as directed
64
-
-
... More
S&F energy efficient LED Tube light fitting with tube 18/20W or nearest size, 240 Volts, 50 Hz, surface mounted, decorative ultra slim square profile LED light fixture with extruded polycorbonate environmental friendly, energy efficient ready to use pack of complete mounting brackets including connecting up with 1.0 Sqmm 3 core flexible copper conductor cable complete all as specified as directed
372
-
-
... More
S & F energy efficient LED security light fitting with tube 30 watts new generatiion energy saving & environmental friendly long life, made up of pressure die cast aluminium housing with high efficient LED as lighting source and PC cover having top opening separate driver compartment with IP66 protection pre-wired and connecting up with with 1.0 Sqmm copper conductor cable upto connector including 1.5 metre long GI tubing light grade bracket of 32 mm dia bend to shape for fixing on wall/ pole with suitable MS bracket nuts, bolts etc., complete all as specified and directed.
12
-
-
... More
Supply, Install, testing and Commissioning integrity of Smart Meter of different makes not more than 33% of particular make to ensure interchangeability at a later date as per BIS 16444 with communication technology including cellular/ RF/ Hybrid [Cellular+RF], AC whole current, three phase, Smart Energy Meter of rating 10-60 Amps complete as per specifications. Meter shall have the ability to communicate with Head End System (HES) on any one of the communication technologies mentioned in IS 16444 Part I (RF/Cellular) in a secure manner, in case of Cellular based meter, the meter shall accommodate e-SIM/ SIM of any service provider, the Smart Meters shall have a dedicated sealable slot for accommodating plug-in type bi-directional communication module which shall integrate the respective communication technology (RF/PLC/ Cellular) with the Smart Meters, leading to easy adaptability for network interfaces (WAN/NAN), the Plug-In module shall be field swappable/ replaceable complete all as specified and directed.
16
-
-
... More
M & L for sub-main wiring with 4.0 sqmm nominal area two single core PVC insulated unshethed multi-stranded FRLS copper conductor cable including one 4.0 sqmm PVC insulated unshethed multi-stranded copper conductor cable for earth wire drawn through 20 mm dia PVC conduit complete all as specified and as directed.
Note :(i) Two run of 4.0 Sqmm + one run of 4.0 Sqmm as a earth wire cable + one run of PVC conduit shall be measured as an one Unit.
220
-
-
... More
M & L for sub-main wiring with 4.0 sqmm nominal area four single core PVC insulated unshethed multi-stranded FRLS copper conductor cable including one 4.0 sqmm PVC insulated unshethed multi-stranded copper conductor cable for earth wire drawn through PVC conduit of suitable size complete all as specified and as directed.
Note :(i) Four run of 4.0 Sqmm + one run of 4.0 Sqmm as a earth wire cable + one run of PVC conduit shall be measured as an one Unit.
160
-
-
... More
Supply and fix polycarbonate meter box as per IS 14772 with IP -55 weather proof and temperature proof,fire retardant suitable for three phase smart pre-paid meter viewing glass, concealed hinge and earth bolt plugged including cable glands for incoming and outgoing cables and locking arrangement for top cover of the box without affecting communication complete all as specified and directed.
16
-
-
... More
M & L for sub-main wiring with 10.0 sqmm nominal area four single core PVC insulated unshethed multi-stranded FRLS copper conductor cable including one 10.0 sqmm PVC insulated unshethed multi-stranded copper conductor cable for earth wire drawn through PVC conduit of suitable size complete all as specified and as directed.
Note :(i) Four run of 10.0 Sqmm + one run of 10.0 Sqmm as a earth wire cable + one run of PVC conduit shall be measured as an one Unit.
120
-
-
... More
M & L for sub-main wiring with 16 sqmm nominal area four single core PVC insulated unshethed multi-stranded FRLS copper conductor cable including one 16.0 sqmm PVC insulated unshethed multi-stranded copper conductor cable for earth wire drawn through PVC conduit of suitable size complete all as specified and as directed.
Note :(i) Four run of 16.0 Sqmm + one run of 16.0 Sqmm as a earth wire cable + one run of PVC conduit shall be measured as an one Unit.
52
-
-
... More
S & F MCCB DB, vertical double door, TPN, 4 way, sheet steel, with 200 Amps rated bus bar, 415 Volts, 50 Hz, IP : 43 protection,concealed in walls, including provision of MCCB FP 40 Amps, 10 KA as incommer and outgoing circuits, filling the empty with blanks, making good the disturbed area as per existing surface complete all as specified and as directed.
1
-
-
... More
S & F MCCB DB, vertical double door, TPN, 4 way, sheet steel, with 200 Amps rated bus bar, 415 Volts, 50 Hz, IP : 43 protection,concealed in walls, including provision of MCB TPN, 10 KA as incommer and outgoing circuits, filling the empty with blanks, making good the disturbed area as per existing surface complete all as specified and as directed.
4
-
-
... More
S & F MCCB DB, vertical double door, TPN, 6 way, sheet steel, with 200 Amps rated bus bar, 415 Volts, 50 Hz, IP : 43 protection,concealed in walls, including provision of MCB TPN, 10 KA as incommer and outgoing circuits, filling the empty with blanks, making good the disturbed area as per existing surface complete all as specified and as directed.
16
-
-
... More
S & F MCB DB, double door, single pole and neutral, 8 way, sheet steel, phospetised powder painted with 200 amps rated bus bar, 240 Volts, neutral link, IP : 43 protection, flush mounting type, concealed in walls complete all as specified and as directed.
1
-
-
... More
S & F MCB DB, double door, single pole and neutral, 4 way, sheet steel, phospetised powder painted with 200 amps rated bus bar, 240 Volts, neutral link, IP : 43 protection, flush mounting type, concealed in walls complete all as specified and as directed.
24
-
-
... More
S & F MCCB, 4 pole, 415 V, 50 Hz, 35 KA of capacity 250 Amps complete all as specified and as directed.
1
-
-
... More
S & F MCB TPN 63 Amps, 415 Volts, 10 KA, 'C' complete all as specified and as directed.
4
-
-
... More
S & F MCB TPN 40 Amps, 415 Volts, 10 KA, 'C' complete all as specified and as directed.
16
-
-
... More
S & F MCB TP 40 Amps, 415 Volts, 10 KA, 'C' complete all as specified and as directed.
24
-
-
... More
Earthing complete with Galvanised steel earth plate electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of plate not less than 1.50 m below normal ground level connected to 4 mm GI Wire [Earth Lead] and GI pipe 15 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the plate by means of GI Bolts & Nuts complete all as per Electrical plate No. 3 of SSR Part - I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. complete all as specified.
5
-
-
... More
Earthing complete with Galvanised steel earth plate electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of plate not less than 1.50 m below normal ground level connected to 32 X 6mm GI Strip [Earth Lead] and GI pipe 50 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the plate by means of GI Bolts & Nuts complete all as per Electrical plate No. 3 of SSR Part - I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. complete all as specified and as directed.
26
-
-
... More
Internal Water Supply
-
-
-
... More
S & F 15 mm dia bib tap two way, fancy type screwed down and fixed suitable for 16 mm inner dia CPVC pipe complete all as specified and as directed.
82
-
-
... More
S & F 15 mm health faucet, chromium plated, fancy type with steel flexible complete suitable for 16 mm outer dia CPVC pipe complete all as specified and as directed.
66
-
-
... More
S & F Brass IVC angular stop cock including connections complete all as specified and as directed.
Make: CAT No. FLR-CHR-5053N of Jaquar or its equivalent as approved by GE.
132
-
-
... More
S & F Brass CP mixer for sink mixing hot & cold water screwed down for CPVC fipe and fixed complete all as specified and as directed.
16
-
-
... More
Sewage disposal
-
-
-
... More
M&L Precast SFRC manhole cover slabs opening size 600x600x70 mm thick , MD-10 Grade, conforming to IS 12592-2002 complete all as specified and as directed.
17
-
-
... More
M&L pre cast SFRC manhole cover slabs opening size 600x600x70mm thick , MD-10 Grade, conforming to IS 12592-2002 complete all as specified and as directed.
13
-
-
... More
External water supply
-
-
-
... More
M& L for ductile iron pipe 100 mm dia, with spigot and socket end centrifugally (spun) cast class K-9 conforming to IS -8329 including provision of special such as tees, elbow, bends reducers tapper pieces (measure seperately) including testing and commissioning complete all as specified and directed.
320
-
-
... More
Supply, install, testing and commissioning of centrifugal pump set of minimum head 42 Mtr and discharge 416 LPM with motor complete electric driven, including star delta starter of appropriate rating , necessary PCC foundation for pump set and starter anlge iron base of suitable size for installation of the pump set also deemed to inclusive, suitable size of copper cable for connection of pump set (Starter should be fixed on panel) complete all as specified and directed.
2
-
-
... More
Supply and fix foot valve of size 80 mm Complete all as specified and as directed.
2
-
-
... More
M & L for masonry valve chamber of size 1050 X 1050 X 1050 mm [interanl dimensions] comprising of 50mm thick PCC for valve including excavation and earth work in any type of soil and 200 mm thick PCC 1:4:8 type D2 foundation, brick work in CM (1:6) plastring internal surface 15 mm tick in CM (1:4) PCC (1:3:6) type B1 couping 50 x50x6 mm angle iron 3 mm thick MS plate cover complete with locking arrangement painting steel and iron surface with two coat of synthetic enamel paint over a coat of zinc chrome primer all as specified and as directed.
3
-
-
... More
Earthing complete with Galvanised steel earth plate electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of plate not less than 1.50 m below normal ground level connected to 25 X 4mm GI Strip [Earth Lead] and GI pipe 50 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the plate by means of GI Bolts & Nuts complete all as per Electrical plate No. 3 of SSR Part - I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. complete all as specified and as directed.
4
-
-
... More
External Electrification
-
-
-
... More
Supply, install, testing and commissioning of 100 KVAR Indoor APFC PANEL floor mounting cubical panel board made with 2 mm thick CRCA sheet individual compartmen system, suitable Aluminium bus bar arrangementp 400 Amps TP MCCB WITH 415 Volts, 50Hz delta connection, super heavy duty square cap capacitor with 05 steps (50+25+15+5+5) Capacitor fixing with suitable contactor with indicating lamps, Automanual selector switch, APFC Realy 6 Amps SPM CBs, Microprocessor based Automatic Power Factor Controller of suitable size voltmeter, Ammeter with selector switch fixing, multifunction CT coils fixing with internal wiring, control earthing, complete Fabrication and Foundation and including connected cabling for incoming and outgoing connection for adjustcent LT feeder pillar box, Complete all as specified and as directed.
MAKE-Havells/C&S/Neptune/Schenider/L&T/Epcos Note:- Accessories and cables required for connections are included in quoted rate.
1
-
-
... More
Supply, install, testing and commissioning of LT Out door control panel weather proof, dust/vermin proof made out of 3.15 mm thick CRCA sheet double opeanable door with angle iron frame and locking arrangement, including bus bar suitable for 3 phase 4 wire system , 415 Volts, 50 Hz, AC Supply with bus bar aluminium 600 Amps capacity including with PVC sleeves/taps RYB colours for phases identification, conforming to IP-54, and fixed on raised PCC platform with PCC 1:2:4 type B1 (20 mm graded aggregated) raised base with control wiring and compressing cable gland brass, copper/brass lugs etc, with and including the following complete all as specified and as directed.
1
-
-
... More
(a) MCCB 4 Pole, 315 Amps, 36 KA - 01 No (for incoming)
(b) MCCB 4 Pole 250 Amps, 25 KA - 02 No (For outgoing)
(c) MCB TP 32 Amps 'C' curve - 01 No (d) Multifunction meters of MFM 4405 LED meter CI 1 CAT No WL 440500000 of following features: (a) Accuracy class 1.0, 0.5,0.05S,0.2,0.2S.
(e) Input voltage measurement range 50-520 VAC (P-P)
(g) Aux supply 80-300 VAC/DC.
(h) CT secondary site selectable 1A/5A.
(j) Flush mounting 96 x 96 mm.
(k) CT/PT Site programmable.
(l) 128 Sample/cycle
(m) Constant Wh vewing in LCD multifunction meters in auto scroll mode.
(n) LCD multifunction meters site suitable for Kwh + 2 Parameters.
(o) Dedicated buttons available for direct access to basic, power and energy parameters.
(p) Phase indication lamps with fuse carriers -01 Set of three
-
-
-
... More
Supply, install, testing and commissioning of LT Outdoor control panel weather proof dust/vermin proof, made out of 3.15 mm thick CRCA sheet double openable door with angle iron frame and locking arrangement, including bus bar suitable for 3 phase 4 wire system, 415 Volts, 50 Hz, AC Supply with bus bar aluminium 400 Amps capacity including with PVC sleeves/taps RYB colours for phases identification, conforming to IP-54, and fixed on raised PCC platform with PCC 1:2:4 type B1 (20 mm graded aggregate) raised base with control wiring and compressing cable gland brass, copper/brass lugs etc., with and including the following complete all as specified and as directed.
1
-
-
... More
(a) MCCB 4 Pole, 125 Amps, 35 KA - 01 (for incoming).
(b) MCCB 4 Pole 63 Amps, 25 KA - 03 (for outgoing).
(c) MCCB TP 32 Amps 'C' Curve - 02 Nos (d) LED Type Phase indication with controlling fuses for RYB - 01 Set.
(e) 3 Phase multifunction energy meter (Voltage 0-500 Volts, ammeter 1-125A energy consumption in KWH or units comsumption including CT's and PT's.
(f) Electrolyte copper busbars, PVC colour sleeved 200 Amps capacity TP.
(g) Danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled red & white with words 'DANGER' 415 Volts Written in English, Hindi & local language, compulsory figures and conventional skull and bones in signal red colour and fixed with MS clamps bolts and nuts of approved size for LT 20 X 15 cm Size - 01 No.
(h) On load change over switch
-
-
-
... More
Supply, install, testing and commissioning of LT Outdoor control panel weather proof dust/vermin proof, made out of 3.15 mm thick CRCA sheet double openable door with angle iron frame and locking arrangement, including bus bar suitable for 3 phase 4 wire system, 415 Volts, 50 Hz, AC Supply with bus bar aluminium 400 Amps capacity including with PVC sleeves/taps RYB colours for phases identification, conforming to IP-54, and fixed on raised PCC platform with PCC 1:2:4 type B1 (20 mm graded aggregate) raised base with control wiring and compressing cable gland brass, copper/brass lugs etc., with and including the following complete all as specified and as directed.
1
-
-
... More
(a) MCCB 4 Pole, 100 Amps, 16 KA - 01 (for incoming).
(b) MCCB 3 Pole 32 Amps, 10 KA - 03 (for out going to Pumps for water supply & Stree light)
(c) 3 Phase multifunctional energy meter (Voltage 0-500 V, ampere 1-125 Amps, energy consumption in KWH or units comsumption including CT's and PT's.
(d) Electrolyte Aluminium busbars, PVC colour sleeved 200 Amps capacity TP.
(e) Danger notice plate of 1.6 mm thick mild steel sheet, vitreous enameled red & white with words 'DANGER' 415 V Written in English, Hindi & local language, compulsory figures and conventional skull and bones in signal red colour and fixed with MS clamps bolts and nuts of approved size for LT 20 X 15 cm Size - 01 No.
-
-
-
... More
Supply and fix 60 watt LED street light fitting pressure die cast aluminium housing heat resistant toughned glass IP:65 protection LED Street light luminaries including GI Bracket made out of 32 mm bore GI Tube, Medium Grade of size not exceeding 2.00 m in length and bent to shape required and fixed with 2 Nos of Pole fitting Clamps made out of MS Flat of size 50 X 6mm, bolts, nuts, washers and painting with two coats of aluminium paint over a coat of primer red oxide zinc chrome primer and connecting up with three core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm complete all as specified and as directed , Make: CAT No. LSTS-72-CDL of Crompton or its equivalent make as approved by GE
12
-
-
... More
Supply and fix HOT Junction box with front cover of size 250x250 x 100 mm (FRP) for street light pole with locking arrangement with IP 66 protection with 32 Amps 4 way heavy duty terminal block with 10 A MCB SP with two steel bracket to fix with pole and aluminium bus bar of rating 200 Amps complete all as specified and directed.
12
-
-
... More
S&F Timeline distrubution board 32Amps, 3 pole, 230 Volts, Digital time switch complete all as specified and directed. Make :- CAT No. TL032DBO of Indoasian or its equivalent in L&T/Siemens
1
-
-
... More
Roads
-
-
-
... More
M&L for Painting lines, dashes, arrows, letters, etc., on roads surface with hot applied retro reflective thermoplastic paint confirming to MORTH (clause 803.40) with 8% glass beads using special applicator machine with heating arrangement upto 160 degree C , including cleaning & drying the road surfaces to ensure dust, oil, grease & moisture free surface before applying paint complete all as specified and directed.
100
-
-
... More
S&F Dual directional reflective cat eye (Road Glow Stud) of impact resistant ABS plastic 100x90x16mm of ultra violet resistant yellow colour, having micro prismatic/cube corner reflectors suitable for fixing with epoxy/bitumen adhesive as per manufacturer's specification/instructions complete all as specified and as directed.
Note: Appropriate epoxy adhesive on the road surface shall be provided as per manufactures specifications/ instructions before fixing the cat eye and the same is deemed to be included in the unit rate quoted.
390
-
-
... More
DG Set
-
-
-
... More
Supply, install, testing and commissioning of silent Diesel Engine Generating set including accoustic enclosure as per CPCB IV Norms 415 Volts, 58.5 KVA, 3 Phase, 0.8 power factor, 50 Hz, 1500 RPM self excited self regulated brushless AC generator with AMF panel of suitable rating, including accoustic enclosure suitable for ambient condition at sea area and conforming to Engine as per IS:10002, ISO-3046, BS-5514 and Alternator as per IS:4774, BS EN 60034-1 with the following accessories including necessary suitable size PCC foundation, GI pipe for laying of cables etc., all as per manufacturers instructions complete all as specified and directed
Make: Kirloskar/ Cummins/Ashok Leyland/ Jyoti/ Crompton
1
-
-
... More
(i) The capacity of Generator set shall be net after all due de-rating factors as per relevent IS design and site condition.
(ii) Rate quoted shall be deemed to be inclusive of cable and terminations from Generator to the AMF Panel, with necessary fixing arrangements all as specified and directed.
(iii) The quoted rate shall be deemed to be inclusive of first fill of oil and final successful acceptance test.
(A) Alternator: Standard design alternator rated at 58.5 KVA net output at site after considering de-rating as per site conditions at 0.8 (lag) power factor, AC, 3 Phase, 4 wire, 415 volts, 50 Hz, 1500 RPM, self excited self regulated screen protected drip proof IP:23 enclosure brushless design with winding in pole faces, insulating class `H' and voltage regulation of +/- 1% at rated Voltage from no load to full load. The alternator shall be conforming to BS 2613/5000 and shall be in a position to generate supply with frequency regulation with in (+) or (-) 1% tolerance. The alternator will be suitable for tropical climate and shall generally conform to BS 2613/5000/IS 4722. Make :Kirloskar /Crompton Greaves/Stamford/CUMMINS
-
-
-
... More
(i) Insulation class & Temparature rise class-H (ii) Excitation : self excited
(iii) Regulation performance : The voltage is kept constant with +/- 1% manual voltage adjustment with in +/-5% (B) Diesel Engine : Adequate capacity of Disesel engine as accepted by the accepting officer based on manufacturers technical details liquid cooled to drive independently above alternator and after considering de-rating as per site conditions after generating and reducing power consumed by accessories directly coupled through flexible coupling multi cylinder multi stroke direct injection, cold starting 1500 RPM, as per relevant /ISI/BS:5514 with an overload capacity of 10% for half an hour in 12 hours continous running complete with standard accessories all as specified and required for safe handling and operation salient features of accessories shall be as under :-
(i) Fly wheel with housing
(ii) cooling system : Moulded radiator with fan & belts. (iii) Cooling water pump : centrifugal type belt driven
-
-
-
... More
(iv) Exhaust system : Exhaust system complete with exhaust piping of suitable dia with MS pipe light grade upto & outside and 1 meter away from the enclosure covered with asbestos rope and aluminium foil of 28 SWG complete with in the enclosure for sale exhaust without transforming vibration to the wall of the enclosure. Exhaust gas turbo charge type Exhaust manifold Silencer: Residual type Make of Diesel Engine : Kirloskar /Cummins/Ashok Leyland (v) Fuel system: Fuel injection system with fuel injectors, fuel injection solenoid switch controlled by electronic governor for 1% speed / frequency regulations, fuel filters, fuel hoses.
(vi) Lub oil system :- (a) Lubricating oil filter, (b) Lubricating oil pump
(vii) Air Intake system :- (a) Air cleaner dry type,
(viii) Governor : Electronic Governor
(ix) Starting system : Electric self starter with maintenance free battery including battery charging alternator.
-
-
-
... More
x) Batteries : Batteries of maintenance free of capacity as recommended by the manufacturer complete with copper conductor multistranded leads of suitable length from self starter to the battery terminals complete with initial charge and initial fill of electrolyte all as specified and starter gear ring start and stop push button, Ignition key switch Handing and operation : Sailent features of accessories shall be as under : (aa) Radiator with Blower fan (ab) Corrosion inhibitor coolant (ac) Paper element filters for fuel, lub oil and by pass (ad) Electronic governor controlled direct fuel injection system (ae) Fly wheel housing and fly wheel
(xi) Generator Monitoring Panel : Comprising of all standard item as mentioned under this schedule / as per standard practice ignition key switch and start/ stop arrangement, indications for Engine parameters hour run meter, RPM meter, Engine oil pressure indicator, water/ coolant temparature indicator, battary volt display.
(xii) Safety controls : Engine low lube oil pressure high water temparature and over speeding of engine
-
-
-
... More
(xiii) Coupling arrangement : Flexible coupling, fly wheel to suit flexible coupling
(xiv) Accessories : AVM pads built or separtely mounted to manufacturer base frames.
(xv) Base frame: Made out of ISMC 250 of sturdy design made of MS channel or as recommended by manufacturer.
(C) AMF panel: Factory made indoor type control cubical made out of 2 mm thick CRCA sheet dust and vermin proof totally enclosed with front and rear opening of 415 Volts, 3 phase, 4 wire, AC, 50 Hz, including powder coated, aluminum bus bar of one and half times the rated load of 58.5 KVA alternator complete with internal wiring with PVC insulated single core copper conductor multi stranded wire of 1100 Volts grade of suitable capacity, fuses name plates consisting of 4 pole MCCB's and contactors and relays of capacity as recommended by the manufacturer, detachable cable gland plates all controls, indicators and Micro processor base LED/LCD display for indication voltage, current, frequency, speed, KW, KWH, PF, temperature,battery voltage,etc with the following:-
-
-
-
... More
(i) indicator lamps - 3 Nos, (ii) Fuse set - 3 Nos (iii) Annuciation with indication lamps for :- (a) Low lub oil pressure (b) High water Temparature (c) Engine over speed (iv) Battery low voltage Controls :- (a) Load on Indication (b) Load off indication (c) Engine start push button (d) Engine stop push button
(v) Fault accept/Reset push button
(vi) Battary Charger : (a) Transformer (b) Rectifier (c) Resistance (d) DC Volt meter (e) Charger rate selector switch
(D) Accoustic Enclosure : Manufactured by OEM suitable for 58.5 KVA DG Set
(i) NAL approved as per CPCB
(ii) It should be as per latest rules and regulations of Ministry of Environment and Forest and pollution control board
-
-
-
... More
(iv) Fuel tank should be inside the enclosure and the capacity of the tank for 12 Hrs run the DG Set.
(v) construction details/specification are as follows:
(vi) Outer Body : CRCA sheet of 1.6 mm thick
(vii) Doors CRCA sheet of 1.6 mm thick
(viii) Sound insulation : As per OEM Norms.
(ix) The accoustic should be composite in construction and fully assembled integral unit
(x) The batteries should be placed inside the enclosure beside the DG set on a suitable insulated plat form
(xi) The cost of the fuel pipe lines is deemed to be included in the quoted rate.
(xii) The DG Set should be provided with external Emergency stop push button
(xiii) The enclosure should be suitably illluminated by CFL/FTL/LED lamp fittings
(xiv) The noise level should be 75 dB at 1m under free field conditions
-
-
-
... More
(xv) The acoustic enclosure parts shall be of powder coated after pre treatment process. The powder coating shade should be Gen set green. The base frame should be painted with epoxy based black shade
(xvi) Rubber matting of LV grade 19 mm thick of suitable size, chequered type, ISI marked shall be laid in front of control panel. (E) Testing: The DG set shall be tested for a period Not less than 12 hours continuously out of which at least 1/2Hr on No Load and 02 hrs on 25% load, 02 hours each on 50% and 2.5 hrs on 75 % of rated full load, 4 hours on rated full load and 01 hours on 10% in exceess of rated full load. Necessary load shall be given on connected load. If the required full load for testing purpose is not available at the site, artificial load has to be arranged by the contractor for the testing. All instruments, consumable stores like engine oil, grease required for carrying out the tests including manpower shall be provided by the contractor. Contractor shall arrange DHPP for testing of DG set . Unit rate quoted shall deemed to include cost of the same.
-
-
-
... More
Fire fighting and fire alarm system
-
-
-
... More
Supply, install, tesing and commissioning of electric driven Terrace pump suitable for automatic operation and consisting of following complete in all respect as required.
(i) Horizontal type, multistage, centrifugal, split casing pump of cast iron body, bronze impeller with stainless steel shaft, mechanical seal and flow of 900 LPM at 35 M head conforming to IS : 1520.
(ii) Suitable HP (15) SQ cage induction motor TEFC type suitable for operation on 415 Volt, 3 Phase, 50 Hz , AC with IP 55 class of protection for enclosure, horizontal foot mounted type class 'F' insulation conforming to IS-325.
(iii) M.S fabricated common base plate, coupling guard foundation bolts etc as required.
(iv) Suitable PCC foundation duly plastered with anti vibration pads.
1
-
-
... More
Supply, Install, Testing & Commissioning of electrical control panel, floor mounted type, fabricated out of 2 mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, inter-connection, having switchgears and accessories mounting and internal wiring, earth terminals, numbering etc., complete in all respect, suitable for operation on 415 Volts, 3 Phase, 50 Hz, AC supply with enclosure protection class IP 42 as required with and including the following
1
-
-
... More
[a] 32 Amps 4P MCB (25 KA)
[b] Voltmeter (0-500 Volt) with selector switch.
[c] Ammeter (0- 400 Amps) with selector switch & suitable CTs (400A / 5A).
[d] Set of 3 phase indication lamp (LED Type)
[e] Suitable HP fully automatic Star Delta Starter with over load protection, current sensing type single phase preventor complete with all accessories and internal wiring required for automatic operation.
[f] Selector switch for local/remote, auto/ manual/off operation
-
-
-
... More
Supply and fix fire extinguishers of Capacity 6.0 kg Dry Chemical Powder (ABC) Typeconsisting of welded MS cylindrical body, squeeze lever discharge valve fitted with pressure indicating gauge internal discharge tube, 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket, conforming to ISI finished externally with red enamel paint and fixed to wall with brackets complete with internal charge complete all as specified and directed.
12
-
-
... More
Supply and fix fire extinguishers of Capacity 4.5 kg CO2 type (light weight squeeze grip type) consisting of welded MS cylindrical body, squeeze lever discharge valve fitted with pressure indicating gauge internal discharge tube, 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket, conforming to ISI finished externally with red enamel paint and fixed to wall with brackets complete with internal charge complete all as specified and directed.
10
-
-
... More
Supply and fix fire extinguishers of Capacity 9.0 ltrs Water stored pressure type consisting of welded MS cylindrical body, squeeze lever discharge valve fitted with pressure indicating gauge internal discharge tube, 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket, conforming to ISI finished externally with red enamel paint and fixed to wall with brackets complete with internal charge complete all as specified and directed.
8
-
-
... More
Supply and fix fire extinguishers of Capacity 9 Ltr Mechanical Foam type consisting of welded MS cylindrical body, squeeze lever discharge valve fitted with pressure indicating gauge internal discharge tube, 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket, conforming to ISI finished externally with red enamel paint and fixed to wall with brackets complete with internal charge complete all as specified and directed.
2
-
-
... More
Supply and fix Fire Buckets with stand and connected equipment complete all as specified and directed.
2
-
-
... More
PVC Conduit
-
-
-
... More
Supply and fix telephone sockets (Jack type) RJ 11-1 with shutter 1 module with all accessories complete all as specified and directed.
32
-
-
... More
Supply and fix TV co-axial socket 1 module with all accessories complete all as specified and directed.
32
-
-
... More
Supply and fix factory fabricated GI Metal flush boxes suitable for 1-2 module complete all as specified and directed.
32
-
-
... More
Supply and fixing of GI junction boxes of size 150 mm x 100 mm x 60 mm with cover plate Complete all as directed.
9
-
-
... More
LIFTS
-
-
-
... More
Supply, install testing & commissioning of electrically operated passenger lift of capacity 13 Passenger (884 Kgs capacity) in the adjusting lift well, 1.5 mtr/Sec speed with automatic micro stroke button control, micro processor based controller simplex selective/collective control suitable for 3 phase, 50 Hz 415 Volt AC supply independent operating with AC variable frequency (AC VVVF) control or closed loop with power saving regenerative drive) with suitable motor gear unit ground floor plu seighth upper floor i.e with 09 stops and 09 landing (G+8) with or without attendent suitable for synchronised operation automatic power operated centre opening (opening as per site requirement)sliding stainless steel door with moon rock finish or 16 gauges with infra red sensors all along the height for car doors with automatic rescue/leveling device (ARD) (with +-5 mm) with suitable batteries, haul position digital indicators in car and all landing with call indicating lights etc including necessary housts and beams for mounting machine in the machine room including all civil works required in connection with erection of lifts complete all as specified. The lift shall be provided with and including the following :-
1
-
-
... More
a) Fire man switch.
(b) Automatic rescue device (ARD) during power failure including manual operation provision with suitable capacity or batteries designed for running the lift with full load.
© Battery operated emergency light (LED Ceiling fitting) alarm ( speaker for emergency alarm system to be fixed) and stop button in car with rechargeable areangement for battery).
(d) Suitable decorative ligting arrangement inside the lift
(e) One sleek circular PVC heavy duty fan in false ceiling.
(f) Aluminium chequred plate (3 mm thick) as flooring joint in chequred plate should not more than one and top covering with PVC flooring complete.
(g) Non stop button/independent operation.
(h) Over load warning indicator both audio and visual type with tripping system having relay etc.
(j) Front landing door of stainless steel moon rock finish operations with a minimum time of 10 seconds and up to a maximum time of 30 seconds.
-
-
-
... More
(k) Car size shall be conform to IS -3531-1976 and body to be stainless steel of 16 gauges moon rock finish with stainless steel hand rail 38 mm hairline finish.
(l) Set of three in number limit switches at the bottom and top most position of lift hoist ways as specified in IS.
(m) Mirror of 4 mm thickenss of suitable size as specified.
(n) Opening with glass door of 5 mm thick 200 x 600 mm size in all the doors.
(o) Specification plate with complete details.
(p) Continuous earthing for machine and equipments.
(q) Steel wire rope of adequate size as per relevent IS and as per manufacturer specifications.
(r) Other standard fixtures and fittings like guide rail, sheaves counter weights with guards, buffer gear unit brakes, control panel, lock, governor, car operational panel, control and trailing cables complete.
(s) Full length display indicator panel.
(u) Suitable phase reversal relay shall be provided on the controller to protect lift /equipment against phase reverse, phase failure and low voltage.
-
-
-
... More
(v) Stainless steel front opened landing door with small opening for vision of size 200mm x 800 mm with toughended glass not less than 08 mm thick.
(w) Intercom be connected with nearest sucurity post. Note:a) Cost of lift inspector inspection is deemed to be inclded in the item rate. provision of one lamp holder, one socket with PVC box of sitable size to be provided at the top of lift for servicing.
b) one lift of 13 passengers only has to be provide with all necessary facilities require for fire lift as per NBC -2016.
-
-
-
... More
All as per item no 61 above but for capacity 08 Passenger (544 Kgs).
1
-
-
... More
Aviation light
-
-
-
... More
Supply and fix Aviation obstruction light LED type fitment-less bulb with 10 Watt bulb complete including standard fixing arrangement complete all as specified and as directed
1
-
-
... More
S & F Cable PVC insulated LT 1100 V grade with copper conductor of size 3 core 2.5 Sqmm multi stranded conductor laid in ground fixed to wall roof etc with suitable calamps spacers bolts nuts etc complete all as specified and as directed
50
-
-
... More
S & F Loop in loop out box of FRP made with IP 65 protection of thermoplastic circuit junction boxes of size 205 x 255 x 112 mm for cable entry and exit combi climate cable glands of IP 66/IP67 for cable entry and grommets IP 65 for conduit of cable exit with MCB SP 6 Amps, 10 KA, C curve over load and short circuit protection terminals as PVC connector heavy duty 32 Amps, 4 way for cable with necessary fixing arrangements an with cable glands, etc complete all as specified and as directed
1
-
-
... More
Supply and fix time switches 250 Volts, single Phase, 20 Amps rating with contactor fitted inside steel enclosure complete all as specified and as directed
1
-
-
... More
Arboriculture
-
-
-
... More
Supply and plant jacaranda mimosifolia [Blue gulmohar] complete all as specified and as directed
30
-
-
... More
Supply and plant Delonix regia [Red gulmohar] complete all as specified and as directed
30
-
-
... More
Supply and plant Acacia auriculiformis [Australian acacia] complete all as specified and as directed
25
-
-
... More
Supply and plant Polyathia longifolia var pendula [Ashok tree] complete all as specified and as directed
25
-
-
... More
Supply and plant Azadirachita indica [neem] complete all as specified and as directed
20
-
-
... More
Supply and plant Mango [hybrid] complete all as specified and as directed
20
-
-
... More
Supply and plant croton hedges height 300 mm above ground level complete all as specified and as directed
100
-
-
... More
Supply and plant best quality carpet grass complete all as specified and as directed
100
-
-
... More
Maintenance of all plants as above complete all as specified and as directed
6
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%