Military Engineer Services Tender

To know what Andhra Pradesh government has posted about any AP etender, Bidassist helps us to get a one-stop platform where a registered bidder can have access to the details on each and every eprocurement tender. There is no need to provide the details on the AP E-procurement website i.e. https://www.apeprocurement.gov.in as BidAssist helps us find the specific etender we're looking for. BidAassist has collated each and every Eproc Andhra Pradesh Tender on its website.

Military Engineer Services - MES Tender

Works
Security and Emergency Services
Eprocure
Opening Date4 Jul 2024
Closing Date5 Sep 2024
Tender Amount₹ 46,50,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
(ii) 20 KVA Capacity at STP Dega Vihar (1 No)

9

-

-

... More
(iii) 30 KVA Capacity at Dega In Living and DSC Pump house (2 Nos)

9

-

-

... More
(iv) 62.5 KVA capacity at ABE Park,New Mine workshop and CNAI (3 Nos)

9

-

-

... More
(v) 82.5 KVA capacity at MOV Old Site and BV Yard (2 Nos)

9

-

-

... More
(vi) 75 KVA BV yard (1 No)

9

-

-

... More
(vi) 100 KVA capacity at MOV Store House and HAWK AJT store house at MOV(old site) (2 Nos)

9

-

-

... More
(vii) 125 KVA capacity at NAD Colony Pump House and BV yard (2 Nos)

9

-

-

... More
(viii) 200 KVA capacity at K-STER Wksp and NBCD (2 Nos)

9

-

-

... More
(ix) 250 KVA capacity at P-195 NAD (1 No)

9

-

-

... More
(vii) 400 KVA for P-17 at MOV(old site) (1 No)

9

-

-

... More
(x) 500 KVA capacity at MOV (Old Site) (1 No)

9

-

-

... More
Maintenance and servicing Diesel Generator Sets including connected Alternator and carrying out routine 'B' check of the engine complete for smooth functioning all as per manufacturer's instructions and as directed. Note :- (a) Control switches such as MCCB, Main switch, contactors, multi display meter and engine control unit shall be out of scope of the item of work and the rate quoted shall exclusive of servicing/ maintenance of the above said fittings. (b) 'B' check shall be carried out once in every six months or 250 hours of running of DG Set whichever is earlier. Servicing of DG Set alonwith connected Alternator and Panel Board including items covered in 'A' check of the Engine shall also be carried out in that month as directed by the Engineer-in-charge and the Contractor shall carry out periodical inspections during the maintenance period and he shall be responsible for the smooth functioning of the DG Set for a period of 30 days from the date of service and shall also attend all the maintenance works as and when required in that period except in case of Major repairs.

-

-

-

... More
(c) Spare parts, engine oil, distilled water and radiator coolant oil required for replacement during the maintenance period shall be measured and paid separately at supply only rates and cost of labour for fixing these spares/filling of oils shall be deemed to be included in the rate quoted for this item. (d) Cost of all consumables required during the maintenance period shall be deemed to be included in the rate quoted for this item. (e) List of checks to be carried out under 'B' check is attached as Appendix 'B' to the Particular specifications.

-

-

-

... More
(i) 15 KVA for INS Viswakarma (1 No)

1

-

-

... More
(ii) 20 KVA Capacity at STP Dega Vihar (1 No)

1

-

-

... More
(iii) 30 KVA Capacity at Dega In Living and DSC Pump house (2 Nos)

2

-

-

... More
(iv) 62.5 KVA capacity at ABE Park,New Mine workshop and CNAI (3 Nos)

3

-

-

... More
(v) 82.5 KVA capacity at MOV Old Site and BV Yard (2 Nos)

2

-

-

... More
(vi) 75 KVA BV yard ( 1 No)

1

-

-

... More
(vi) 100 KVA capacity at MOV Store House and HAWK AJT store house at MOV(old site) (2 Nos)

2

-

-

... More
(vii) 125 KVA capacity at NAD Colony Pump House and BV yard (2 Nos)

2

-

-

... More
(viii) 200 KVA capacity at K-STER Wksp and NBCD (2 Nos)

2

-

-

... More
(ix) 250 KVA capacity at P-195 NAD (1 No)

1

-

-

... More
(vii) 400 KVA for P-17 at MOV(old site) (1 No)

1

-

-

... More
(x) 500 KVA capacity at MOV (Old Site) (1 No)

1

-

-

... More
Maintenance and servicing of following mentioned Diesel Generator Sets including connected Alternator, and carrying our routine 'C' check of the engine complete for smooth functioning all as per manufacturer's instructions and as directed. Note :- (a) Control switches such as MCCB, Main switch, contactors, multi display meter and engine control unit shall be out of scope of the item of work and the rate quoted shall exclusive of servicing/ maintenance of the above said fittings. (b) 'C' check shall be carried out once in every YEAR or 500 hours of running of DG set whichever is earlier. Servicing of DG Set alonwith connected Alternator and Panel Board including items covered in 'A' & 'B' check of the Engine shall also be carried out in that month as directed by the Engineer-in-charge and the Contractor shall carry out periodical inspections during the maintenance period and he shall be responsible for the smooth functioning of the DG Set for a period of 30 days from the date of service and shall also attend all the maintenance works as and when required in that period except in case of Major repairs.

-

-

-

... More
(c) Spare parts, engine oil, distilled water and radiator coolant oil required for replacement during the maintenance period shall be measured and paid separately at supply only rates and cost of labour for fixing these spares/filling of oils shall be deemed to be included in the rate quoted for this item. (d) Cost of all consumables required during the maintenance period shall be deemed to be included in the rate quoted for this item. (e) List of checks to be carried out under 'C' check is attached as Appendix 'B' to the Particular specifications. QUOTED RATES INCLUDING all spares like B CHECK service kit and other consumable under 'C' check service, except oil & coolant

-

-

-

... More
(i) 15 KVA for INS Viswakarma (1 No)

1

-

-

... More
(ii) 20 KVA Capacity at STP Dega Vihar (1 No)

1

-

-

... More
(iii) 30 KVA Capacity at Dega In Living and DSC Pump house (2 Nos)

1

-

-

... More
(iv) 62.5 KVA capacity at ABE Park,New Mine workshop and CNAI (3 Nos)

3

-

-

... More
(v) 82.5 KVA capacity at MOV Old Site and BV Yard (2 Nos)

2

-

-

... More
(vi) 75 KVA BV yard ( 1 No)

1

-

-

... More
(vi) 100 KVA capacity at MOV Store House and HAWK AJT store house at MOV(old site) (2 Nos)

2

-

-

... More
(vii) 125 KVA capacity at NAD Colony Pump House and BV yard (2 Nos)

1

-

-

... More
(viii) 200 KVA capacity at K-STER Wksp and NBCD (2 Nos)

1

-

-

... More
(ix) 250 KVA capacity at P-195 NAD (1 No)

1

-

-

... More
(vii) 400 KVA for P-17 at MOV(old site) (1 No)

1

-

-

... More
(x) 500 KVA capacity at MOV (Old Site) (1 No)

1

-

-

... More
Supply only fuel filter elements

-

-

-

... More
(i) 15 KVA to 30 KVA

4

-

-

... More
(ii) 62.5 KVA to 82.5 KVA

8

-

-

... More
(iii) 100 KVA to 125 KVA

4

-

-

... More
(iv) 200 KVA to 250 KVA

4

-

-

... More
(v) 400 KVA to 500 KVA

2

-

-

... More
Supply only lube oil super bypass filter for 200 to 250 KVA DG Set

4

-

-

... More
Supply only lube oil super bypass filter for 400 KVA to 500 KVA DG Set

2

-

-

... More
Supply only lube /engine oil filter/cartridges as per sample and make of the following capacities of DG sets

-

-

-

... More
(i) 15 KVA to 30 KVA

4

-

-

... More
(ii) 62.5 KVA to 82.5 KVA

8

-

-

... More
(iii) 100 KVA to 125 KVA

4

-

-

... More
(iv) 200 KVA to 250 KVA

4

-

-

... More
(v) 400 KVA to 500 KVA

2

-

-

... More
Overhauling of following mentioned radiator assy of following DG sets by disconnecting and removing from engine, dismantling the top & bottom chambers, descaling the sediments and scales, corrosion ..etc by means of acid cleaning and high pressure water washing, air cleaning, re-assembling the same with new gaskets, including arresting leakage, if any and fixing to the engine with new hoses ,clipes as reqd Note : The rate quoted shall be inclusive of transporting of the radiator to the workshop and back and all incidental charges.

-

-

-

... More
(i) 15 KVA to 30 KVA

2

-

-

... More
(ii) 62.5 KVA to 82.5 KVA

4

-

-

... More
(iii) 100 KVA to 125 KVA

2

-

-

... More
(iv) 200 KVA to 250 KVA

2

-

-

... More
(v) 400 KVA to 500 KVA

1

-

-

... More
Supply only Lead acid battery PVC body 12 volt 180 AH

1

-

-

... More
Supply only Lead acid battery PVC Body 12 volt 150 AH

1

-

-

... More
Supply only Lead acid battery PVC body 12 volt 130 AH

1

-

-

... More
Supply and filling radiator coolant

450

-

-

... More
Supply and filling distilled water

400

-

-

... More
Supply only fan belts for replacement of u/s fan belts of following capacities of DG set as per sample size all as directed.

-

-

-

... More
(i) 15 KVA to 30 KVA

2

-

-

... More
(ii) 62.5 KVA to 82.5 KVA

4

-

-

... More
(iii) 100 KVA to 125 KVA

4

-

-

... More
(iv) 200 KVA to 250 KVA

3

-

-

... More
(v) 400 KVA to 500 KVA

2

-

-

... More
M & L for checking servicing and overhauling calibration of the injector pump with injectors of following capacities of DG SETS . These rates deem to be included for necessary sealing rings , "O" rings if needs replacement etc., and render necessary test servicing certificate from the authorised dealer.

-

-

-

... More
(i) 15 KVA to 30 KVA

2

-

-

... More
(ii) 62.5 KVA to 82.5 KVA

4

-

-

... More
(iii) 100 KVA to 125 KVA

2

-

-

... More
(iv) 200 KVA to 250 KVA

2

-

-

... More
(v) 400 KVA to 500 KVA

1

-

-

... More
Opening the coupling, dismantling the alternator carefully removing the flywheel , dismantling the unserviceable Fly wheel , supply and fixing new staring ring gear wheel , fixing back the alternator and properly coupled back all as directed for 15 KVA to 30 KVA

1

-

-

... More
Opening the coupling, dismantling the alternator carefully removing the flywheel , dismantling the unserviceable starting ring gear wheel , supply and fixing new Fly wheel , fixing back the alternator and properly coupled back all as directed for 62.5 KVA to 82.5 KVA

1

-

-

... More
Opening the coupling , dismantling the alternator carefully removing the flywheel Ring , dismantling the unserviceable Fly wheel, supply and fixing new starting ring gear wheel , fixing back the alternator and properly coupled back all as directed for 100 KVA to 125 KVA

1

-

-

... More
Opening the coupling , dismantling the alternator carefully removing the flywheel Ring , dismantling the unserviceable Fly wheel, supply and fixing new starting ring gear wheel , fixing back the alternator and properly coupled back all as directed for 200 KVA to 250 KVA

1

-

-

... More
Opening the coupling , dismantling the alternator carefully removing the flywheel Ring , dismantling the unserviceable Fly wheel, supply and fixing new starting ring gear wheel , fixing back the alternator and properly coupled back all as directed for 400 KVA to 500 KVA

1

-

-

... More
Dismantling/repairing the cylinder head assy for Kirloskar engine by stripping out the head assy from engine and carrying out the machining work such as head surfacing pressure testing, valve seat angle facing, lapping replacing the rusted water plugs and fixing the new brass water plugs etc., and replacing the worn out parts like inlet & exhaust valves guides , valves seat inserts, head gaskets, stem seal, silicon "O" rings and re-testing etc., complete as reqd. including the transportation and taking down all requisite parts as required and refixing the same of capacity 100 KVA

1

-

-

... More
Dismantling/repairing the cylinder head assy for Kirloskar engine by stripping out the head assy from engine and carrying out the machining work such as head surfacing pressure testing, valve seat angle facing, lapping replacing the rusted water plugs and fixing the new brass water plugs etc., and replacing the worn out parts like inlet & exhaust valves guides , valves seat inserts, head gaskets, stem seal, silicon "O" rings and re-testing etc., complete as reqd. including the transportation and taking down all requisite parts as required and refixing the same of capacity 125 KVA

1

-

-

... More
M/L overhauling the 100/125 KVA DG SET (Make-Kirloskar) by removing engine from chassis and disconnecting the fuel lines and exhaust connections and transporting to workshop replacing the u/s parts like piston - 6 Nos., rings - 6 sets cylinder liner 06 Nos. after cleaning the engine block and fixing the new parts like connecting rod, bearing. cylinder liners - 6 Nos. set of joints complete, oil seals, reassembling the engine with new parts. After reassembling cooling the engine testing and commissioning etc., as directed including taking down all requisite parts as required and refixing the same .

1

-

-

... More
Overhauling the fuel injection pump assembly and injectors for 20/30/62.5 KVA DG set , dismantling and taking out to workshop for repair including transportation by replacing the worn out/unserviceable parts like service kit, D - Valve, Elements and nozzles., etc., as required, mentioned and calibration the same, commissioning etc., as required.

1

-

-

... More
(a) Element MICO - 4 Nos.

-

-

-

... More
(b) Delivery valve MICO - 4 Nos.

-

-

-

... More
(c) Swelling lever MICO -1 No.

-

-

-

... More
(d) Bearings (SKF/NBC) - 2 Nos.

-

-

-

... More
(e) Nozzle MICO - 4 Nos.

-

-

-

... More
Supply only Voltage Regulator (AVR) suitable for DG set of capacity 100 KVA to 125 KVA

1

-

-

... More
Supply only Voltage Regulator (AVR) suitable for DG set of capacity 82.5/62.5/30/20 KVA

2

-

-

... More
Supply only Low Oil pressure Switch 12V 1.7 kg/Sq.mm

1

-

-

... More
Supply only battery lead

24

-

-

... More
Supply only stopping solenoid 24 Volt suitable for 500 KVA Capacity

1

-

-

... More
Supply only stopping solenoid 12 Volt suitable for the following DG sets

-

-

-

... More
a) DG set of capacity 125 KVA to 100 KVA

1

-

-

... More
b) DG Set of capacity 62.5 KVA to 82.5 KVA

3

-

-

... More
c) DG Set of capacity 20 KVA to 30 KVA

1

-

-

... More
Supply only battery terminal made of brass

12

-

-

... More
Supply only Benjo bolts of suitable sizes

12

-

-

... More
Supply only fuel pipe filter

6

-

-

... More
Supply only anti vibration pad

12

-

-

... More
Supply only Radiator hose flexible suitable for the following DG sets

-

-

-

... More
(a) 15 KVA to 30 KVA

1

-

-

... More
(b) 62.5 KVA to 82.5 KVA

1

-

-

... More
(c) 100 KVA to 125 KVA

1

-

-

... More
(d) 200 KVA to 250 KVA

1

-

-

... More
(e) 400 to 500 KVA

1

-

-

... More
Supply only Hose plain for water pump suitable for the following DG sets

-

-

-

... More
(a) 15 KVA to 30 KVA

1

-

-

... More
(b) 62.5 KVA to 82.5 KVA

1

-

-

... More
(c) 100 KVA to 125 KVA

1

-

-

... More
(d) 200 KVA to 250 KVA

1

-

-

... More
(e) 400 KVA to 500 KVA

1

-

-

... More
Supply only DC Ammeter of Range 0-10 A

2

-

-

... More
Supply only Lube oil pressure gauge of suitable range

2

-

-

... More
Supply only starter motor assembly for 125/100 KVA, 12 volt DC

1

-

-

... More
Supply only Turbo Charger Core assembly 200 to 500 KVA capacity

1

-

-

... More
Supply only Air Filter elements of following DG Set as given bellow :-

-

-

-

... More
(a) 15 KVA to 30 KVA

2

-

-

... More
(b) 62.5 KVA to 82.5 KVA

3

-

-

... More
(c) 100 KVA to 125 KVA

2

-

-

... More
(d) 200 KVA to 250 KVA

2

-

-

... More
(e) 400 KVA to 500 KVA

1

-

-

... More
Supply only A series electronic timers on delay function with time range 0.3S to 30 Min.

1

-

-

... More
Supply only B series electronic timers adjustable cyclic function 240 Volts AC suitable for AMF panel.

1

-

-

... More
Supply only '' ON DELAY TIMERS (for STOP/START/LOP/LOT/FAULT etc) Time range 3 sec to 30 hours contact 5 Amps 240V/12-24 volts DC

1

-

-

... More
Supply only HRC fuses of capacity 4-20 Amps.

6

-

-

... More
Supply only HRC fuse cartridge assembly both base and top 20A rating.

3

-

-

... More
Supply only indicator lamps DC filament type

3

-

-

... More
Supply only indicator lamps AC 230 Volt LED Type for the panel boards.

6

-

-

... More
Supply only push button with contact element 5 A with NO-NC

3

-

-

... More
Supply only Selector switch for Voltmeter and Ammeter.

3

-

-

... More
Supply only Ammeter as per sample of range 0-30/50/100 Amps AC for control/AMF panel

3

-

-

... More
Supply only Volt Meter as per sample of Range 0-600 Volts AC.

3

-

-

... More
Supply only Frequency meter vibrating reed of Range 45-55 HZ.

3

-

-

... More
Supply only Frequency meter blinking type LED type of Range 45-55 HZ.

3

-

-

... More
Supply only main contactor L & T Type MNX 110A 2NO+2NC 3 Pole suitable for AMF Panel.

1

-

-

... More
Supply only main contactor Make : L & T, Type ML 3 Pole suitable for AMF panel.

2

-

-

... More
Supply only main 3P contactor for AMF panel as required for 125 / 100KVA DG set

1

-

-

... More
Supply only contactor(neutral control) for AMF panel, model MNX 32 of 125 KVA DG set.

2

-

-

... More
Supply only main contactor for AMF panel model TCA3-M40 of 30/45/62.5 KVA DG set.

2

-

-

... More
Supply only main contactor 4P for AMF panel model MCX 11, 50 Amps for 20/30/62.5 KVA DG set.

1

-

-

... More
Supply only contactor 4P for AMF panel model MCX 47 , 800 Amps for 400/500 KVA DG set.

2

-

-

... More
Supply only auxiliary /control contactors of suitable contactor(2NO, 02NC) of suitable ratings for AMF Panel.

1

-

-

... More
S&F Battery charger 24 v SMPS(System main power supply) type control unit assembly.

1

-

-

... More
S&F Battery charger 12 v SMPS(System main power supply) type control unit assembly.

1

-

-

... More
Supply and fix HMI 320 PCC 3.3 Display unit, P/N 0300-6315-02 for Cummins DG Set of 500 KVA including connected accessories required on site complete all as specified and directed

1

-

-

... More
Supply only ignition key suitable for DG set panel/control panel.

2

-

-

... More
Supply only Energy meter 3 phase, 4 wire, 20-40 Amps range microprocessor based

1

-

-

... More
Supply only voltage monitoring regulator (UV, OV, SP) of suitable ratings for AMF panels

1

-

-

... More
Supply only MCB TP 20 Amps rating.

1

-

-

... More
Supply only MCB TP nominal rating 32 Amps

1

-

-

... More
Supply only MCB TP nominal rating 40 Amps

1

-

-

... More
Supply only MCB TP nominal rating 63 Amps

1

-

-

... More
Supply only MCB TPN nominal rating 20 Amps

1

-

-

... More
Supply only MCB TPN nominal rating 32 Amps

1

-

-

... More
Supply only MCB TPN nominal rating 40 Amps

1

-

-

... More
Supply only control MCCB 4 Pole 100A 16 KA suitable for AMF panels

1

-

-

... More
Supply only PF meter digital, flush mounting type.

1

-

-

... More
Supply only Multifunction digital meter (in lieu of voltmeter, ammeter, Pfmeter) suitable for new version AMF panel.

1

-

-

... More
Supply only in replacement of PVC insulated unsheathed multi stranded copper conductor cable FRLSH as per IS-694 for sizes :-

-

-

-

... More
(a) 1.5 Sqmm

30

-

-

... More
(b) 2.5 Sqmm

30

-

-

... More
(c) 4 Sqmm

30

-

-

... More
(d) 6 Sqmm

45

-

-

... More
Supply and replace in repair - MCCB 3 pole 25-100A 16KA - in LT panel boards / feeder pillar boxes including disconnecting and removing existing defective item from electric circuit including necessary connected fasteners, burnt cables, accessories etc,. all as per site requirement/existing make/model all as specified and as directed.

1

-

-

... More
All as per item No 80 above but of size 100-125A 25KA

1

-

-

... More
All as per item No 80 above but of size 160-200A 25KA

1

-

-

... More
All as per item No 80 above but of size 250A 36KA

1

-

-

... More
S&F in repairs Change over switch 4 pole 125A without enclosure.

1

-

-

... More
S&F in repairs Change over switch 4 pole 63A without enclosure.

1

-

-

... More
S&F in repairs Change over switch 4 pole 63A in sheet metal enclosure.

1

-

-

... More
S&F in repairs Change over switch 4 pole 100A in sheet metal enclosure.

1

-

-

... More
S & F in repairs Ductile Iron Pipes 150 mm bore Ductile Iron Pipes centrifugally cast (spun) including jointing in standard length, with flanged ends, Class "K9" conforming to IS 8329-2000 (latest version) in any length laid in trenches including taking down unserviceable old one , all as specified and directed.

120

-

-

... More
S & F in repairs Ductile Iron Pipes 100 mm bore Ductile Iron Pipes centrifugally cast (spun) including jointing in standard length, with flanged ends, Class "K9" conforming to IS 8329-2000 (latest version) in any length laid in trenches including taking down unserviceable old one , all as specified and directed.

30

-

-

... More
Supply & fix DI fittings in repairs (pressure class K-9) such as bends, (any type, radius and angle), Tapers any type (straight bend, increasing, decreasing or double socket etc) Tee piece single branch "Y" junction double branch, cross (all socket or socket and spigot) collars, caps and plugs of size up to 200mm bore confirming to IS 9523-2000 including taking down unserviceable old one , all as specified and directed.

300

-

-

... More
Material and labour in repairs for framed work such as valve chamber covers, static tank cover, base frames for pump sets, protection covers for pump sets/panel boards, staging for water tank , ladders etc complete all as specified.

200

-

-

... More
M & L for pressure testing of existing CI / DI / MS of water supply / fire lines of 150 mm dia for identifying leakages for rectifications including replacement of gland packing of sluice valves, rubber insertion packing, nut ,bolts etc of flanged joints / defective flanges etc complete for making the system leak proof complete all directed by Engineer-in-charge. Note: (a) The rate quoted is deemed to be inclusive of T&P such as air compressor for pressure testing etc (b) Earthwork, DI / MS pipe & specials required for rectification if any shall be measured and paid separately under relevant items BOQ. (c) Pressure test will be carried out either complete network or partial pipelines of any size / distance as per ground requirement.

5

-

-

... More
M & L for arresting water leakage from sluice valve, by refacing, regrinding of sluice Valve, Repacking stuffing box of sluice valve spindle including taking apart and reassembling the same including replacing old check nuts with new one made out of MS / CI material, with and including replacing perished gland packing, rubber gasket, bolts and nuts complete all as directed for the following sizes :-

-

-

-

... More
80 mm dia bore

30

-

-

... More
100 mm dia bore

6

-

-

... More
150 mm dia bore

6

-

-

... More
M & L for repairs to automatic control panel of fire fighting system for effective functioning of jockey pump to maintain desired pressure level in the system including replacement of minor spares, control wiring etc as required on site and all as directed by Engr in Charge

2

-

-

... More
M & L for replacement of Double Headed, GUN METAL Fire Hydrant Landing Valve of Type B of size 63 mm dia including all Joints and Jointing Materials complete all as specified and as directed.

5

-

-

... More
M & L for replacement of Single Headed, GUN METAL Fire Hydrant Landing Valve of Type A of size 63 mm dia including all Joints and Jointing Materials complete all as specified and as directed.

8

-

-

... More
M & L for replacement of GUN METAL branch pipe 63mm dia instantaneous inlet, made traded outlet, 15mm bore nozzle short complete including removing existing unserviceable all as directed.

8

-

-

... More
M & L for replacement of Single Headed, SS Type, Fire Hydrant Landing Valve of Type A of size 63 mm dia including all Joints and Jointing Materials complete all as specified and as directed.

15

-

-

... More
M & L for rectification of existing defective / leakage flanged joints with rubber or fibre gasket complete with necessary nuts, bolts and washers all as specified for 80 mm dia pipe lines of DI / MS / GI pipes complete all as directed. Note:- (a) quoted rates are inclusive of cutting of DI / MS / GI Pipes, jointing materials and preparation of new flanged sockets and re fixing the same at existing place. (b) Necessary excavation and pipes are measured and paid separately.)

6

-

-

... More
All as per item No 99 above but for 100 mm dia pipe

3

-

-

... More
All as per item No 99 above but for 150 mm dia pipe

6

-

-

... More
All as per item No 99 above but for 200 mm dia pipe

2

-

-

... More
Material and labour for PCC (1:3:6) type C1 using 20 mm graded stone aggregate as a base foundation / making pedestals for the pipelines including one coat of white wash and necessary form work complete all as specified.

1.3

-

-

... More
Supply and fix in reair flanged end lift type Foot valve 150 mm dia (Strainer for suction) with brass strainer, suitable flanges, nuts, bolts, gaskets complete all as specified and directed.

2

-

-

... More
Supply and fix in reair flanged end lift type Foot valve 100 mm dia (Strainer for suction) with brass strainer, suitable flanges, nuts, bolts, gaskets complete all as specified and directed.

2

-

-

... More
Supply and fix in reair flanged end lift type Foot valve 80 mm dia (Strainer for suction) with brass strainer, suitable flanges, nuts, bolts, gaskets complete all as specified and directed.

1

-

-

... More
M & L for taking down & re fixing the old fire hydrant valves of size 80mm dia from hydrant post by removing the corrosion, changing the damaged pins from pivot end, softening the shaft of iron wheel and applying the grease for lubrication of fire hydrant valves complete all as directed by EIC. Note : 1. quoted rates are inclusive of Nut & Bolts and other connected items.

25

-

-

... More
M & L for repair/ maintenance of fire hose box by changing of damaged doors along with locking arrangements, front glass of existing size and necessary rubber gaskets for doors complete all as directed by Engineer-in-Charge. (Note:- Quoted rates are inclusive of one coat red-oxide paint, paint red and inside clean white paint)

25

-

-

... More
S & F in repairs of defective/ unserviceable 15 mtrs long percolating canvas hose of 80/63mm dia CP male and female coupling conforming to IS 903 all as directed by Engr-in-charge.

12

-

-

... More
S & F in repairs of damaged / defective / unserviceable first aid hose reel hose with 19mm bore 30 mtrs, hose reel tubing Rubber hose IS:884- 1985, shut off valve and 4.6mm dia nozzle as per IS 8090 1976, manufactured as per IS 884/85 complete all as specified on fire fighting norms and as directed.

3

-

-

... More
Supply, and replace defective/ unserviceable four way fire brigade inlet with isolation valve with instantaneous gun metal coupling 63mm dia complete all as per fire standards made out of 150mm dia class 'B' MS pipe all as specified. Make:-WINCO/ AAG / Minimax / New Age

3

-

-

... More
Supply and replace Fire Hose cabinet of size 800 mm x 600 x 250 mm made out of 18 gauge MS Sheet with double door having 4 mm thick glass marked with "FIRE POINT AND IN CASE OF FIRE BREAK THE GLASS" in signal red paint for keeping the fire hoses nozzles etc., The MS Sheet cabinet shall be painted with a coat of zinc chrome primer and two coats of postal red colour epoxy paint outside and brilliant white inside of approved make and installed near the stand post type hydrant complete all as specified and as directed.

10

-

-

... More
Supply and fix sluice valve of class PN 1.6 dia 150mm (6") IS complete including inserting and jointing material bolt, nuts and gasket after dismantling and taking out unserviceable sluice valve all as directed by Engr-in-charge.

2

-

-

... More
Supply and fix sluice valve of class PN 1.6 dia 100mm (4") IS complete including inserting and jointing material bolt, nuts and gasket after dismantling and taking out unserviceable sluice valve all as directed by Engr-in-charge.

2

-

-

... More
Supply and fix sluice valve of class PN 1.6 dia 80mm (3") IS complete including inserting and jointing material bolt, nuts and gasket after dismantling and taking out unserviceable sluice valve all as directed by Engr-in-charge.

8

-

-

... More
Supply and fix butterfly valve dia 150mm (6") IS complete including inserting and jointing material bolt, nuts and gasket after dismantling and taking out unserviceable butterfly valve all as directed by Engr-in-charge.

2

-

-

... More
S & top up engine oil 15W40 or as per manufacturer's recommendations.

500

-

-

... More
Supply and fix in repair water pressure gauges of 0-14 kgs standard dia at delivery side of pump sets complete with connecting tubing, fitted with stop cocks etc all standard practice and as directed.

4

-

-

... More
M & L Preparation of old painted steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying one coat of synthetic enamel paint. complete all as specified and as directed.

500

-

-

... More
M & L for cleaning of vegetation by using excavator for removing bushes / thick vegetation around the pump house, installations, levelling the area without damaging the pipelines / Cable network / Pedestals of pipelines / buildings including disposal of the vegetation / debris material up to a distance not exceeding 50 m complete all as specified and directed by Engineer-in-Charge.

3000

-

-

... More
Supply and replacement of single hydrant stand post made of MS pipe of size 80 mm bore heavy grade, 1.20 m to 1.5 m height with 90°, duck foot bend both end flanged and including welding if required to suit single fire hydrant valve and testing complete all as specified and directed by Engineer - in - Charge.

8

-

-

... More
Supply and Fix in replacement "Fire Hydrant Blanking Cap of PVC for closing the fire hydrant valves of 63/80 mm dia complete along with chain all as specified and directed by Engineer - in - Charge.

25

-

-

... More
Supply and Fix in replacement "Fire Hydrant Hand Wheel" for closing the fire hydrant valves of 63/80 mm dia complete all as specified and directed by Engineer - in - Charge.

30

-

-

... More
Supply and Fix in replacement "Fire Hydrant Female Coupling Washers of both ends" suitable of 63 mm dia complete all as specified and directed by Engineer - in - Charge.

50

-

-

... More
Supply and Fix in repair Female outlet (Adapter) Gun metal in existing Hydrant valve (both type A and B) of size 63mm all as specified and directed by Engineer-in-Charge

50

-

-

... More
Material and labour for taking down defective foot valves from UG Sump, removing corrosion and painting with one coat of red oxide along with black enamel paint and replacing rubber gaskets, foot valve bottom rubber with spring complete with renewal of necessary bolts, nuts, washers complete all as specified for 150 / 100 mm dia size of foot valves.

3

-

-

... More
M & L Synthetic mat (rubber matting) suitable for 1100 Volts electrical grade 2mx1mx19mm thick chequered top, ISI marked to be laid in front of LT panel board complete all as specified and directed.

3

-

-

... More
M& L for Brickwork with fly ash bricks, straight or curved on plan exc 6M mean radius built in CM 1:4, complete all as specified and directed.

1

-

-

... More
M & L for 15 mm thick rendering in cement mortar 1:4 on fair faces of concrete or brick surface mixed with water proofing compound as per manufacturer's instruction finished even and fair without using extra cement including two coats of white washing complete all as specified and directed.

2

-

-

... More
Supply only MS pipe 200mm dia bore, heavy grade laid in trenches or on ground / vertically with welded joints including removing the rusted, broken old MS pipe all as directed.

20

-

-

... More
Supply only MS pipe 150mm dia bore, heavy grade laid in trenches or on ground / vertically with welded joints including removing the rusted, broken old MS pipe all as directed.

24

-

-

... More
Supply only MS pipe 100mm dia bore, heavy grade laid in trenches or on ground / vertically with welded joints including removing the rusted, broken old MS pipe all as directed.

18

-

-

... More
Supply only MS pipe 80mm dia bore, heavy grade laid in trenches or on ground / vertically with welded joints including removing the rusted, broken old MS pipe all as directed.

12

-

-

... More
Excavation in trenches in soft/loose soil n.exc. 1.5M wide & n exc 1.5M deep for laying of GI/CI pipe line & getting out including forming bottom surface all as specified and directed.

65

-

-

... More
Returning, filling in, trenches including spreading, levelling, watering and well ramming in layer n.exc. 250 mm in any type of soil after the pipe laid & tested complete all as specified and directed.

58

-

-

... More
Removing excavated surplus soil to a distance n.exc. 50mtr and depositing where directed at a level n.exc. 1.5 m above the starting point all as specified and directed

7

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.