Military Engineer Services Tender

To know what Andhra Pradesh government has posted about any AP etender, Bidassist helps us to get a one-stop platform where a registered bidder can have access to the details on each and every eprocurement tender. There is no need to provide the details on the AP E-procurement website i.e. https://www.apeprocurement.gov.in as BidAssist helps us find the specific etender we're looking for. BidAassist has collated each and every Eproc Andhra Pradesh Tender on its website.

Military Engineer Services - MES Tender

Works
Civil And Construction
Civil Works Others
Eprocure
Opening Date26 Dec 2024
Closing Date30 Jan 2025
Tender Amount₹ 12,67,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Lump Sum price worked out by the contractor for 'Internal Water Supply', as listed in Schedule 'A' Part-III.

1

9192

-

... More
Lump Sum price worked out by the contractor for 'Internal Electrification', as listed in Schedule 'A' Part-IV.

1

47213

-

... More
Lump Sum price worked out by the contractor for 'External Water Supply', as listed in Schedule 'A' Part-V.

1

71417

-

... More
Lump Sum price worked out by the contractor for 'External Electrification', as listed in Schedule 'A' Part-VI.

1

625920

-

... More
Lump Sum price worked out by the contractor for 'Area Drainage', as listed in Schedule 'A' Part-VII.

1

1583103

-

... More
Lump Sum price worked out by the contractor for 'Sewage Disposal', as listed in Schedule 'A' Part-VIII.

1

132941

-

... More
Lump Sum price worked out by the contractor for 'Road/Path/Culvert', as listed in Schedule 'A' Part-IX.

1

6338629

-

... More
Lump Sum price worked out by the contractor for 'Fire Fighting', as listed in Schedule 'A' Part-X.

1

539683

-

... More
Lump Sum price worked out by the contractor for 'Fire Alarm & Detection System', as listed in Schedule 'A' Part-XI.

1

173900

-

... More
SCHEDULE 'A' PART-XII: (MISCELLANEOUS ITEMS):

-

-

-

... More
INTERNAL WATER SUPPLY:

-

-

-

... More
S&F two way bib taps 15mm dia. cast copper alloy chromium planted fancy type with butterfly handle, screwed down for pipes complete all as specified and as directed by the Engineer-in-Charge.

1

-

-

... More
S&F angle stop valve 15mm dia., with urinal water dropper, fancy type cast copper alloy, with capstan heads, chromium plated, screwed down high pressure pipes complete all as specified and as directed by the Engineer-in-Charge.

1

-

-

... More
S&F angle stop valve 15mm dia., fancy type cast copper alloy, with capstan heads, chromium plated, screwed down high pressure pipes complete all as specified and as directed by the Engineer-in-Charge.

1

-

-

... More
INTERNAL ELECTRIFICATION:

-

-

-

... More
Point wiring with 1.5 Sq.mm. FRLS PVC insulated unsheathed copper conductor multi stranded 1100 Volts grade, ISI marking drawn through and including non metallic PVC rigid concealed conduit and conduit accessories medium grade, ISI marked, including modular metal flush box with and including modular white cover plate with frame for mounting modular switches/sockets/fan regulators etc. including one run of 1.5 Sq.mm. PVC insulated unsheathed copper cable for earth continuity, connected to earth dolly, for One light/bell point controlled by one no. one way switch or One fan (ceiling fan/exhaust fan/wall mounted) point controlled by one switch or one 3 pin socket outlet 5 Amps on independent board complete all as specified and as directed by the Engineer-in-Charge.

35

-

-

... More
All as per item No.15 here-in-before but for one 3 pin socket outlet 5 Amps on same board.

5

-

-

... More
All as per item No.15 here-in-before but for one 3 pin socket outlet 15 Amps on independent board with 4 Sq.mm. FRLS PVC wire and one run of 4 Sq.mm. copper cable for earth continuity.

1

-

-

... More
All as per item No.15 here-in-before but for flame proof fixtures /fittings, copper conductor drawn through stove enamelled steel conduit.

57

-

-

... More
All as per item No.15 here-in-before but for flame proof fixtures /fittings, but with 2.5 Sq.mm. size copper conductor drawn through stove enamelled steel conduit.

1

-

-

... More
M&L sub main wiring concealed type with PVC insulated FRLS copper conductor cable unsheathed for circuit along with earth wire including PVC rigid conduit medium grade 20mm dia. with accessories complete with two runs of 4 Sq.mm. cable and one run of 4 Sq.mm. earth wire complete with colour coding and making good the disturbed area complete all as specified and as directed by the Engineer-in-Charge.

120

-

-

... More
M&L sub main wiring concealed type with PVC insulated FRLS copper conductor cable unsheathed for circuit along with earth wire including PVC rigid conduit medium grade 20mm dia. with accessories complete with two runs of 6 Sq.mm. cable and one run of 6 Sq.mm. earth wire complete with colour coding and making good the disturbed area complete all as specified and as directed by the Engineer-in-Charge.

40

-

-

... More
M&L sub main wiring concealed type with PVC insulated FRLS copper conductor cable unsheathed for circuit along with earth wire including PVC rigid conduit medium grade 20mm dia. with accessories complete with two runs of 10 Sq.mm. cable and one run of 10 Sq.mm. earth wire complete with colour coding and making good the disturbed area complete all as specified and as directed by the Engineer-in-Charge. Note for Item Nos.20 to 22: Two runs of cable, one run of earth wire and one run of conduit will be measured as one unit.

80

-

-

... More
S&F switch flame Proof rotary type with termination box in LM6, 6/16A, single pole 250 Volts complete all as specified and as directed by the Engineer-in-Charge.

57

-

-

... More
S&F flame proof switch socket & plug combined in LM6 cable termination box in LM6 16 Amps, 250 Volts, 2P+ earth complete all as specified and as directed by the Engineer-in-Charge.

1

-

-

... More
S&F energy efficient LED tube light fitting with tube 20 Watts, 240 Volts, 50 Hz, surface mounted, decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack of complete with mounting bracket etc. including connecting up with 1.0 Sq.mm. 3 core flexible copper conductor cable complete all as specified and as directed by the Engineer-in-Charge.

7

-

-

... More
S&F energy efficient LED tube light fitting with tube 2x20 Watts, 240 Volts, 50 Hz, surface mounted, decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack of complete with mounting bracket etc. including connecting up with 1.0 Sq.mm. 3 core flexible copper conductor cable complete all as specified and as directed by the Engineer-in-Charge.

5

-

-

... More
S&F LED security light fitting with tube 30 Watt new generation energy saving & environmental frindly, long life, made up of pressure die cast aluminium housing with high efficient LED as lighting source and PC cover having top opening separate driver compartment with IP66 protection pre wired with 1.5 Sq.mm. copper conductor cable up to connector including 1.5m long GI tubing light grade of 32mm dia. bend to shape for fixing on wall/pole with suitable MS brackets nuts and bolts etc. complete all as specified and as directed by the Engineer-in-Charge.

16

-

-

... More
S&F energy efficient 100 Watt LED Flame proof wellglass fitting in diecast at housing with heat resistant toughened glass made of aluminium alloy LMG , CIMFR certified recommended for gas/vapour group of IIM & IIB and zone 1&2 with IP 65 protection complete with all accessories prewired and including connecting up with suitable twin core twisted flexible copper conductor cable of suitable size etc all as specified and directed.

35

-

-

... More
S&F energy efficient Flame proof cum water proof LED Bulk head light fitting of 30 Watt IP66 protection of cast aluminium alloy material and heat and impact resistance toughen 'A' clear glass having anticorrosive epoxy powder coated finiwh complete with all accessories prewired including connecting up with suitable size 3 core flexible copper conductor cable complete all as specified and as directed by the Engineer-in-Charge.

12

-

-

... More
S&F energy efficient LED light fitting of 2x16 Watt IP66 flame proof CMRI certified recommended forgas/vapour group IIM& IIB and zone 1&2 with IP 65 protection with die cast aluminium alloy material and heat and impact resistance toughened glass having anticorrosive epoxy powder coated finiwh complete with LED tube light fixtures drivers, holders, connectors all accessories prewired including connecting up with suitable size 3 core flexible copper conductor cable complete all as specified and as directed by the Engineer-in-Charge.

12

-

-

... More
S&F ceiling fan complete with blades, down rods, and accessories, 230 Volts, 1200mm sweep, minimum air delivery 210 CFM with service value 6.0 BEE five star rated with brushless direct current motor (BLDC) with and including flexible copper wire 1 Sq.mm. form ceiling rose to connector of ceiling fan complete all as specified and as directed complete all as specified and as directed by the Engineer-in-Charge.

2

-

-

... More
S&F exhaust fan made out of sturdy engineering plastic complete with louvers shutter, 230 Volt, 50 Hz, 1200 RPM copper winding of sweep 250mm, fixed on wall including making opening, fixing and making good the distrubed surfaces etc complete with and inclussive of making necessary electric connection from ceiling rose to fan through 1 Sq.mm. twin core flexible wire complete all as specified and as directed by the Engineer-in-Charge.

1

-

-

... More
S&F exhaust fan made out of sturdy engineering plastic complete with louvers shutter, 230 Volt, 50 Hz, 1200 RPM copper winding of sweep 300mm, fixed on wall including making opening, fixing and making good the distrubed surfaces etc complete with and inclussive of making necessary electric connection from ceiling rose to fan through 1 Sq.mm. twin core flexible wire complete all as specified and as directed by the Engineer-in-Charge.

2

-

-

... More
S&F concealed in wall Flame proof SPN MCB DB double door type, SPN 8 way, 415 Volts, 50 Hz, IP 43 protection with 200 Amps rated bus bar including supply and fixing MCB SPN 32 Amp as incommer and 6 Nos out going circuits MCB SP-6 Nos. complete, filling empty way with blanking plates complete all as spcified and as directed by the Engineer-in-Charge.

2

-

-

... More
M&L earthing complete with GI plate electrode 60cmxx60cmx6mm thick, buried directly in ground (Earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to GI wire 4mm dia. by means of bolts, nuts, check nuts and washers of copper all as shown in electrical plate No.3 of SSR Part-I connected to earhing test point all as specified or indicated including excavation and connected earth work in hard/dense soil, PCC 1:3:6 type C1 as in pit, 20mm dia. GI pipe medium grade for watering pipe, 15mm bore GI light grade earth lead protection pipe, and 50mm thick RCC cover slab with handle, reinforced with 10mm dia. bars in both the directions, funnel, strainer, charcoal and testing on complete all as specified and as directed by the Engineer-in-Charge. Notes: 1. Rate quoted deemed to include GI protection pipe, funnel, excavation and earth work, in soft/loose soil with PCC type C1 in bed and pit complete all as specified and as directed. 2. Earth lead up to 7.50m length is deemed to be included in the quoted rate the beyond 7.5m length will be measured and paid separately.

2

-

-

... More
EXTERNAL WATER SUPPLY:

-

-

-

... More
M&L laying of ductile iron pipe 100mm dia. with spigot and socket end centrifugally (spun) cast class K-9 conforming to IS-8329 including provision of specials, such as tees, elbows, bends reducers, taper pieces (Quoted rates are inclusive of DI specials), including testing and commissioning complete all as specified and as directed by the Engineer-in-Charge.

350

-

-

... More
M&L brick masonry valve chamber of size 1000x1000x1000mm (Internal dimensions) comprising of 50mm thick PCC for valve including excavation and earth work in any type of soil and 200mm thick PCC 1:4:8 type D2 foundation, brick work in CM 1:6, plastring internal surface 15mm tick in CM 1:4, PCC 1:3:6 type C1 coping, 50x50x6mm angle iron frame for door, 3mm thick MS plate for cover complete with locking arrangement painting to steel and iron surface with two coat of synthetic enamel paint over one coat of zinc chrome primer and three coats of white wash on plastered surfaces complete all as shown on drawing and as specified and as directed by the Engineer-in-Charge.

2

-

-

... More
M&L for cutting existing GI steel tubing 150mm dia. for alterations or additions necessarily done in position with out taking down and inserting 'TEE' of size 150x150x100mm for tapping ccomplete all as specified and as directed by the Engineer-in-Charge.

1

-

-

... More
EXTERNAL ELECTRIFICATION:

-

-

-

... More
Supply, install, test and commissioning of transformer step down 11/0.433KV with HT 3 phase and LT 3 Phase 4 wire system copper wound with off load tap changing arrangement on HT side for a variation of secondary voltage +/- 7.5% insteps of 2.5% continuous rating of 125 KVA outdoor type conforming to IS1180 (Level 2) and comprising of the following specification and fittings complete all as specified and as directed by the Engineer-in-Charge: Continuous Rating: 125 KVA No-Load Voltage Ratio 11 KV/433 V Tapping on HV(%): +7.5, + 5, 2.5 Phase & Frequency: 3 Phase & 50 HZ Connection: Delta Star Vector Group: DYN 11 Cooling: ONAN Type: outdoor Fittings: (a) Externally hand Operated off- Circuit Tap Switch with position indicator and locking device. (b) Conservator with Oil Gauge, filling hole with plug &drain hole with plug. (c) Undercarriage with four plan rollers (d) Oil filling hole cumair release plug (e) Drain valve cum sampling valve (f) Top Filter Valve with Diagram Plate (g) Rating Plate with Diagram Plate (h) Lifting lugs for Transformer (j) Lifting lugs for core (k) Earthing Terminal (l)Thermometer Pockets

1

-

-

... More
(m) silica Breather (n) Explosion Vent (p) Double Float Buchholz with alarm and troop contacts including control cable of copper conductor of size & length from Marshalling Box to relay of VCB (q) 150mm size Oil Temperature inductor, dial type with alarm and trip contacts (r) 150mm size winding Temperature indicator, dial type with alram and trip contacts (s) Buchholz Relay with 2 Shut-off valve (t) Marshalling Box with Doubal Winding (u) OCTC Note: The quoted rate includes excavation, removal of soil including PCC 1:2:4 foundation type B2 of Size not less than 4.60X3.00 X 0.80m for placing of transformer complete all as specified and as directed by the Engineer-in-Charge.

-

-

-

... More
Supply, fabricated, install test and commissioning LT out door control panel weather proof, dust/vermin proof made out of 3.15 mm thick CRCA sheet double opeanable door with angle iron frame and locking arrangement, including bus bar suitable for 3 phase 4 wire system , 415 V 50 Hz, AC Supply with bus bar aluminium 400 Amps capacity including with PVC sleeves/taps RYB colours for phases identification, conforming to IP-54, and fixed on raised PCC platform with PCC 1:2:4 type B1 (20 mm graded aggregated) raised base with control wiring and compressing cable gland brass, copper/brass lugs etc., and compressing the following items conforming to CPRI approved manufacturer with multifunctioning meter and accessories necessary internal electric connection as required complete all as specified and as directed by the Engineer-in-Charge: (a) MCCB 4 Pole, 250 Amps, 36 KA-01 No. (For incoming) (b) MCCB 4 Pole, 200 Amps, 36 KA-02 Nos. (For out going for AMF panel & spare) (c) MCB TP 63 Amps-01 No. (Outgoing for APFC panel) (d) Multifunction meters of MFM 4405 LED meter CI 1 Cat. No.WL 440500000 of following features: (i) Accuracy class 1.0, 0.5, 0.055, 0.2, 0.2S. (ii) Input voltage measurement range 50-520 VAC (P-P) (iii) Aux supply 80-300 VAC/DC. (e) CT secondary site selectable 1A/5A. (f) Flush mounting 96x96mm. (g) CT/PT Site programmable. (h) 128 Sample/cycle (j) Constant Wh viewing in LCD multifunction meters in auto scroll mode. (k) LCD multifunction meters site selectable for Kwh + 2 Parameters. (l) Dedicated buttons available for direct access to basic, power and energy parameters. (m) Phase indicator lamps with fuse carriers -01 Set of Three

1

-

-

... More
Supply, fabricate, install, test and commissioning LT outdoor control panel weather proof dust/vermin proof, made out of 3.15 mm thick CRCA sheet double openable door with angle iron frame and locking arrangement, including bus bar suitable for 3 phase 4 wire system, 415 V, 50 Hz AC Supply with bus bar aluminium 400 Amps capacity including with PVC sleeves/taps RYB colours for phases identification, conforming to IP-54, and fixed on raised PCC platform with PCC 1:2:4 type B-1 (20 mm graded aggregate) raised base with control wiring and compressing cable gland brass, copper/brass lugs etc. and compressing the following items conforming to CPRI approved manufactures (Standby DG Panel) and accessories necessary internal electric connection as required complete all as specified and as directed by the Engineer-in-Charge: Incoming: (a) MCCB 4 Pole, 200 Amps, 35 KA-01 No. (For incoming). Outgoing: (a) MCCB 4 Pole, 160 Amps, 25 KA-03 Nos. (For outgoing) (01 No.A/C plant & spare). (b) MCCB TP, 32 Amps 16 KA-02 Nos. (01 No. for Building & 01 for Crane) (c) MCB TPN 20 Amp-02 Nos. (01 No. street light & 01 No. Spare) (d) LED Type Phase indicator with controlling fuses for RYB-01 Set. (e) 3 Phase multifunction energy meter (Voltage: 0-500 Volts, ampere 1-125 Amps energy consumption in KWH or unit consumption including CTs and PTs. (f) Electrolyte copper bus bars, PVC colour sleeved 200 Amps capacity TP. (g) Danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled red & white with words 'DANGER' 415 V Written in English, Hindi & local language, compulsory figures and conventional skull and bones in signal red colour and fixed with MS clamps bolts and nuts of approved size for LT 20 X 15 cm Size - 01 No. (h) ON load change over switch

1

-

-

... More
Supply, installation, testing and commissioning of 60 KVAR indoor APFC panel floor mounting cubical panel board made with 2mm thick CRCA sheet individual compartment system, suitable Aluminium bus bar arrangement 400 Amps TP MCCB WITH 415 v 50HZ delta connection, super heavy duty square cap capacitor with 6 steps (5+3x10+2x12.5) Capacitor fixing with suitable molar contactor with indicating lamps, Auto manual selector switch, APFC relay 6 Amps SPM CBs, voltmeter, Ammeter with selector switch fixing, multifunction CT coils fixing with internal wiring, control earthing, complete Fabrication and Foundation and including connected cabling for incoming and outgoing connection for adjacent LT feeder pillar box complete all as specified and as directed by the Engineer-in-Charge.

1

-

-

... More
S&F Integral LED street light fitting 70 Watt, 230 Volts, AC, IP 65 with inbuilt surge protection device comprising of epoxy powder coated Pressure die cast aluminium housing enclosed wih glass cover in frame, PVC insulated three core flexible cable of suitable size and length duly connected to light fitting complete including installation and testing complete all as specified and as directed by the Engineer-in-Charge.

15

-

-

... More
S&F street light fitting bracket of 40mm dia medium grade GI pipe 1.5m length fixed with 40mm x 5mm clamp of suitable length fixed with reuired nuts, bolts and washers and two coats of synthetic enamel paint over one coat of redoxide primer on steel surfaces complete all as specified and as directed by the Engineer-in-Charge.

15

-

-

... More
S&F Loop in loop out box of FRP made with IP 65 protection of thermoplastic circuit breaker boxes with metric knockouts for cable entry and exit, combi-climate cable glands of IP 65 for cable entry and grommets IP 65 for conduit for cable exit with MCB 6 Amps, 10 KA, ‘C’ Curve overload and short circuit protection, terminals as bus terminals for cable with necessary fixing arrangements and with cable glands, etc. complete all as specified and directed.

15

-

-

... More
Supply and lay cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of following sizes complete all as specified and as directed by the Engineer-in-Charge;

-

-

-

... More
3½ core 95 Sq.mm.

80

-

-

... More
2 core 70 Sq.mm.

90

-

-

... More
4 core 16 Sq.mm.

40

-

-

... More
4 core 10 Sq.mm.

740

-

-

... More
Supply laying & testing cable XLPE insulated screened PVC bedded, galvanized steel strip armoured, electric power cables (heavy duty) with stranded aluminium conductor, 11000 Volts grade, of sixe 3 core 120 Sq.mm. complete all as specified and as directed by the Engineer-in-Charge.

572

-

-

... More
S&F for cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 Sq.mm. complete all as specified and as directed by the Engineer-in-Charge.

1

-

-

... More
S&F for cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 Sq.mm. complete all as specified and as directed by the Engineer-in-Charge.

1

-

-

... More
M&L earthing complete with GI plate electrode 60cmxx60cmx6mm thick, buried directly in ground (Earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised iron earth strip 32x6mm by means of bolts, nuts, check nuts and washers of copper all as shown in electrical plate No.3 of SSR Part-I connected to earhing test point all as specified or indicated including excavation and connected earth work in hard/dense soil, PCC 1:3:6 type C1 as in pit, 20mm dia. GI pipe medium grade for watering pipe, 15mm bore GI light grade earth lead protection pipe, and 50mm thick RCC cover slab with handle, reinforced with 10mm dia. bars in both the directions, funnel, strainer, charcoal and testing on complete all as specified and as directed by the Engineer-in-Charge. Notes: 1. Rate quoted deemed to include GI protection pipe, funnel, excavation and earth work, in any type of soil with PCC type C1 in bed and pit complete all as specified and as directed. 2. Earth lead up to 7.50m length is deemed to be included in the quoted rate the beyond 7.5m length will be measured and paid separately.

12

-

-

... More
AREA DRAINAGE:

-

-

-

... More
M&L pre-cast cement concrete block masonry with solid PCC blocks of grade C5 conforming to IS-2185 Part-I, in CM 1:6, exc. 10cm in width and setting in mortar complete all as specified and as directed by the Engineer-in-Charge.

270

-

-

... More
SEWAGE DISPOSAL:

-

-

-

... More
M&L pre-cast cement concrete block masonry with solid PCC blocks of grade C5 conforming to IS-2185 Part-I, in CM 1:6, exc. 10cm in width and setting in mortar complete all as specified and as directed by the Engineer-in-Charge.

20.59

-

-

... More
M&L for pre-cast SFRC 900mmx900mmx100mm EHD-35 Extra Heavy Duty (Square) manhole cover slabs conforming to IS 12592-2002, set in cement mortar (1:4) complete all as specified and as directed by the Engineer-in-Charge.

8

-

-

... More
M&L for 20 Users RCC septic tank designed to carry sewage and sullage water including excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in walls, base slab, baffle walls and roof slab including beams etc. with vent shaft, manhole openings with cover connection etc., complete with effective depth of 1.2m and overall depth of 2.35m complete all as specified and as directed by the Engineer-in-Charge.

1

-

-

... More
M&L for soakage well of size 1.80m dia. x 3.00m effective depth including excavation in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of RCC M-25 including intercepting chamber and screen chamber made of brick masonry in CM (1:4), RCC cover slab in M-25/SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of required size complete all as specified and as directed by the Engineer-in-Charge.

1

-

-

... More
ROAD/PATH/CULVERT:

-

-

-

... More
M&L granular sub base (GSB) with grading V of 200mm thick compacted thickness (Laid in two layers of 100mm each, compacted seperately) confirming to grading as specified, spread, rolled & consolidated to required gradient and camber complete using necessary mechanical paver/grader & vibratory soil compacter of capacity 8-10 Ton complete all as specified and as directed by the Engineer-in-Charge. Notes: 1. Payment shall be made for solid quantity arrived after consolidation. 2. Compaction of granular sub base filling shall be carried out under optimum moisture condition to achieve 98.50% modified density. 3. Curing shall be carried out as per IRC recommendations. 4. Before execution of this item the approved material obtained from outside MD land shall be tested/Checked for suitability to use. 5. Contractor shall use vibratory earth compactor in lieu of power roller to achieve 98.50% MDD at OMC without any extra cost and the method of compaction to be adopted as per recommendation of agency reporting MDD at OMC. 6. GSB shall be as per MORTH specification as detailed in particular specification.

306

-

-

... More
M&L pre-cast cement concrete block masonry with solid PCC blocks of grade C5 conforming to IS-2185 Part-I, in CM 1:6, exc. 10cm in width and setting in mortar complete all as specified and as directed by the Engineer-in-Charge.

10.8

-

-

... More
M&L painting lines, dashes, arrows, letters etc. on roads surface with hot applied retro reflective thermoplastic paint confirming to MORTH (Clause 803.40) all as specified with 8% glass beads using special applicator machine with heating arrangement up to 160oC, including cleaning & drying the road surfaces to ensure dust, oil, grease & moisture free surface before applying paint complete all as specified and as directed by the Engineer-in-Charge.

150

-

-

... More
LIGHTNING PROTECTION:

-

-

-

... More
S&F single pointed air terminal aluminium rod 12mm dia. 300mm long with aluminium box plate of size of 125x125x10mm fixed over porcelain insulator and fixed on roof top complete including 40mm dia. medium grade MS pipe 300mm long and including necessary fasteners fixed for lighting protection with necessary connections to earthing etc. complete all as specified and as directed by the Engineer-in-Charge.

33

-

-

... More
S&F horizontal roof conductor and down conductor of size 25mmx3.15mm aluminium strip fixed to walls/columns/projections/ roof including porcelain blocks/DMC insulator spaced at 1m interval complete all as specified and as directed by the Engineer-in-Charge.

400

-

-

... More
S&F horizontal roof conductor and down conductor of size 20mmx3.15mmmm copper strip fixed to walls/columns/projections/ roof including porcelain blocks/DMC insulator spaced at 1m interval complete all as specified and as directed by the Engineer-in-Charge.

240

-

-

... More
S&F horizontal roof conductor and down conductor of size 25mmx4mm Galvanised Iron strip fixed to walls/columns/projections/roof including porcelain blocks/DMC insulator spaced at 1m interval complete all as specified and as directed by the Engineer-in-Charge.

80

-

-

... More
S&F test point terminal block made out of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos. 8mm dia. 25mm long hexagonal head screws etc. complete all as specified and as directed by the Engineer-in-Charge.

8

-

-

... More
M&L earthing complete with GI plate electrode 60cmxx60cmx6.3mm thick, buried directly in ground (Earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised iron earth strip 32x6mm by means of bolts, nuts, check nuts and washers of copper all as shown in electrical plate No.3 of SSR Part-I connected to earhing test point all as specified or indicated including excavation and connected earth work in hard/dense soil, PCC 1:3:6 type C1 as in pit, 20mm dia. GI pipe medium grade for watering pipe, 40mm bore GI light grade earth lead protection pipe, and 50mm thick RCC cover slab with handle, reinforced with 10mm dia. bars in both the directions, funnel, strainer, charcoal and testing on complete all as specified and as directed by the Engineer-in-Charge. Notes: 1. Rate quoted deemed to include GI protection pipe, funnel, excavation and earth work, in any type of soil with PCC type C1 in bed and pit complete all as specified and as directed. 2. Earth lead up to 7.50m length is deemed to be included in the quoted rate the beyond 7.5m length will be measured and paid separately.

8

-

-

... More
M&L earthing complete with Copper Earth plate electrode 60cmxx60cmx3.15mm thick, buried directly in ground (Earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to copper earth strip 20x3mm by means of bolts, nuts, check nuts and washers of copper all as shown in electrical plate No.3 of SSR Part-I connected to earhing test point all as specified or indicated including excavation and connected earth work in hard/dense soil, PCC 1:3:6 type C1 as in pit, 20mm dia. GI pipe medium grade for watering pipe, 15mm bore GI light grade earth lead protection pipe, and 50mm thick RCC cover slab with handle, reinforced with 10mm dia. bars in both the directions, funnel, strainer, charcoal and testing on complete all as specified and as directed by the Engineer-in-Charge. Notes: 1. Rate quoted deemed to include GI protection pipe, funnel, excavation and earth work, in soft/loose soil with PCC type C1 in bed and pit complete all as specified and as directed. 2. Earth lead up to 7.50m length is deemed to be included in the quoted rate the beyond 7.5m length will be measured and paid separately.

5

-

-

... More
M&L for pedestal for fixing air termination rod, with cement concrete in foundation, filling and mass concrete with PCC 1:3:6 type C2 with 40mm graded aggregate of size 30cmx30cmx30cm and 1.00 Mtr. Long GI pipe light grade including clamps, nuts, bolts etc. complete all as specified and as directed by the Engineer-in-Charge.

33

-

-

... More
FIRE FIGHTING SYSTEM:

-

-

-

... More
M&L laying of Mild steel flanged pipe 150mm dia. with spigot and socket duly painted with two coats of synthetic enamel paint over a coat of red oxide primer conforming to IS-3589.91 including provision of specials, such as tees, elbows, bends reducers, taper pieces (measure separately), including testing and commissioning complete all as specified and as directed by the Engineer-in-Charge.

350

-

-

... More
Supply and install fire extinguisher CO2 Type light weight squeeze grip type confirming to IS 15683 of capacity 4.5 Kg complete all as specified and as directed by the Engineer-in-Charge. Notes: 1. Fire extinguisher should be equipped with hose of appropriate size and open-close should be with the help of wheel type valve. 2. Fixing arrangement to wall will be included in the quoted rates.

6

-

-

... More
Supply and install fire extinguisher ABC Type light weight squeeze grip type confirming to IS: 15683 of capacity 6.0 Kg complete all as specified and as directed by the Engineer-in-Charge. Notes: 1. Fire extinguisher should equipped with hose of appropriate size and open-close should be with the help of wheel type valve. 2. Fixing arrangement to wall will be included in the quoted rates. 3. Appropriate size of sign board should be hanged from wall/roof near the all fire pints.

6

-

-

... More
Supply and install fire extinguisher Mechanical Foam Type light weight squeeze grip type confirming to IS: 15683 of capacity 9.0 Kg complete all as specified and as directed by the Engineer-in-Charge. Notes: 1. Fire extinguisher should equipped with hose of appropriate size and open-close should be with the help of wheel type valve. 2. Fixing arrangement to wall will be included in the quoted rates. 3. Appropriate size of sign board should be hanged from wall/roof near the all fire pints.

6

-

-

... More
Providing and fixing 4 Nos. GI sand buckets painted Red Colour complete with GI stand duly painted Red Colour, of suitable size to hang 3 buckets at a time as per required specifications complete all as specified and as directed by the Engineer-in-Charge.

2

-

-

... More
Supply and fix Fire symbol board of standard size complete all as specified and as directed by the Engineer-in-Charge.

2

-

-

... More
M&L brick masonry valve chamber of size 1000x1000x1000mm (Inner dimensions) comprising of 50mm thick PCC for valve including excavation and earth work in any type of soil and 200mm thick PCC 1:4:8 type D2 foundation, brick work in CM 1:6, plastring internal surface 15mm tick in CM 1:4, PCC 1:3:6 type C1 couping, 50x50x6mm angle iron, 3mm thick MS plate cover complete with locking arrangement painting to steel and iron surface with two coat of synthetic enamel paint over one coat of zinc chrome primer complete all as shown on drawing and as specified and as directed by the Engineer-in-Charge.

2

-

-

... More
M&L for cutting existing GI steel tubing 150mm dia. for alterations or additions necessarily done in position with out taking down and inserting 'TEE' of size 150x150x100mm for tapping ccomplete all as specified and as directed by the Engineer-in-Charge.

1

-

-

... More
FIRE ALARM SYSTEM:

-

-

-

... More
S&F PVC insulated PVC sheathed armoured cable LT 1100 Volts grade with copper conductor of size 2 core 1.5 Sq.mm. multi stranded conductor laid in ground fixed to wall roof etc. with suitable clamps, spacers, bolts, nuts etc. omplete all as specified and as directed by the Engineer-in-Charge.

350

-

-

... More
FLAME PROOF FITTINGS:

-

-

-

... More
S&F switch flame Proof rotary type with termination box in LM6, 6/16A, single pole 250 Volts complete all as specified and as directed by the Engineer-in-Charge.

25

-

-

... More
S&F flame proof switch socket & plug combined in LM6 cable termination box in LM6 16 Amps, 250 Volts, 2P+ earth complete all as specified and as directed by the Engineer-in-Charge.

20

-

-

... More
S&F LED light fitting 2x16 watt flame proof , CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 &@ and IP65 protection with die cast aluminium housing with heat resistant toughened glass with LED tube light fixtures driver, holders, connectors etc. Complete with all acessories prewired and inclding connecting up with three core cable flexible copper conductor cable with suitable size complete all as specified and as directed by the Engineer-in-Charge.

50

-

-

... More
S&F Flame proof -wheather proof encloser for MCB DB SPN 10 way incoming 63 amp MCB including gas cut ring endless Neoprene rubber gas kit IP 66 as per IS 2147/1962 ISI marked made out of cast aluminium alloy LM-6,epoxy painted CMRI certified AC supply one incomming and 8 nos out going MCB 6A to 32 A complete all as specified and as directed by the Engineer-in-Charge.

1

-

-

... More
S&F Flame proof -wheather proof encloser for MCB DB SPN 6 ways with incoming 20 amp DP including gas cut ring endless Neoprene rubber gas kit IP 66 as per IS 2147/1962 ISI marked made out of cast aluminium alloy LM-6,epoxy painted CMRI certified AC supply 230 volts one incomming and 4 nos out going MCB 6A to 16 A complete all as specified and as directed by the Engineer-in-Charge.

5

-

-

... More
M&L flame proof sub main wiring concealed type with PVC insulated FRLS copper conductor cable unsheathed for circuit along with earth wire including ERW MS conduit medium grade 20mm dia. with accessories complete with two runs of 1.5 Sq.mm. cable and one run of 1.5 Sq.mm. earth wire complete with colour coding and making good the disturbed area complete all as specified and as directed by the Engineer-in-Charge.

550

-

-

... More
M&L flame proof sub main wiring concealed type with PVC insulated FRLS copper conductor cable unsheathed for circuit along with earth wire including ERW MS conduit medium grade 25mm dia. with accessories complete with two runs of 2.5 Sq.mm. cable and one run of 2.5 Sq.mm. earth wire complete with colour coding and making good the disturbed area complete all as specified and as directed by the Engineer-in-Charge.

250

-

-

... More
M&L flame proof sub main wiring concealed type with PVC insulated FRLS copper conductor cable unsheathed for circuit along with earth wire including ERW MS conduit medium grade 25mm dia. with accessories complete with two runs of 4 Sq.mm. cable and one run of 4 Sq.mm. earth wire complete with colour coding and making good the disturbed area complete all as specified and as directed by the Engineer-in-Charge. Note for Item Nos.81 to 83: Two runs of cable, one run of earth wire and one run of conduit will be measured as one unit.

530

-

-

... More
M&L earthing complete with GI plate electrode 60cmxx60cmx6.3mm thick, buried directly in ground (Earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to GI wire 4mm dia. by means of bolts, nuts, check nuts and washers of copper all as shown in electrical plate No.3 of SSR Part-I connected to earhing test point all as specified or indicated including excavation and connected earth work in hard/dense soil, PCC 1:3:6 type C1 as in pit, 20mm dia. GI pipe medium grade for watering pipe, 15mm bore GI light grade earth lead protection pipe, and 50mm thick RCC cover slab with handle, reinforced with 10mm dia. bars in both the directions, funnel, strainer, charcoal and testing on complete all as specified and as directed by the Engineer-in-Charge. Notes: 1. Rate quoted deemed to include GI protection pipe, funnel, excavation and earth work, in soft/loose soil with PCC type C1 in bed and pit complete all as specified and as directed. 2. Earth lead up to 7.50m length is deemed to be included in the quoted rate the beyond 7.5m length will be measured and paid separately.

2

-

-

... More
M&L earthing complete with Copper Earth plate electrode 60cmxx60cmx3.15mm thick, buried directly in ground (Earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to copper earth strip 20x3mm by means of bolts, nuts, check nuts and washers of copper all as shown in electrical plate No.3 of SSR Part-I connected to earhing test point all as specified or indicated including excavation and connected earth work in hard/dense soil, PCC 1:3:6 type C1 as in pit, 20mm dia. GI pipe medium grade for watering pipe, 15mm bore GI light grade earth lead protection pipe, and 50mm thick RCC cover slab with handle, reinforced with 10mm dia. bars in both the directions, funnel, strainer, charcoal and testing on complete all as specified and as directed by the Engineer-in-Charge. Notes: 1. Rate quoted deemed to include GI protection pipe, funnel, excavation and earth work, in soft/loose soil with PCC type C1 in bed and pit complete all as specified and as directed. 2. Earth lead up to 7.50m length is deemed to be included in the quoted rate the beyond 7.5m length will be measured and paid separately.

10

-

-

... More
DG SET:

-

-

-

... More
Supply installation testing and commissioning of silent engine generating set with acoustic enclosure as per CPCB norms IV 415 volts 125 KVA 3 Phase 0.8 power factor 50 Hz, 1500 RPM self-excited self-regulated brushless AC generator including acoustic enclosure suitable for ambient condition and conforming to condition under IS 4774, BS EN 60034-1 with and including the following complete all as specified and as directed by the Engineer-in-Charge: (A) Alternator: Standard design alternator rated at 125 kVA net output at site after considering de-rating as per site conditions at 0.8 (lag) power factor AC, 3 Phase, 4 Wire, 415 Volts, 50 Hz, 1500 RPM, self-excited self-regulated screen protected drip proof IP 23 enclosure brushless design with winding in pole faces, insulating class 'H' and voltage regulation of +/-1% at rated voltage from no load to full load. The alternator shall be conforming to BS 2613/5000 and shall be imposition to generate supply with frequency regulation within +/- 1% tolerance. The alternator will be suitable for tropical climate and shall generally conform to BS-2613/5000/ IS-4722. (i) Insulation class: 'H‘ (ii) Temperature rise Class: 'H‘ (iii) Excitation: Self Excited (iv) Regulation performance: The voltage is kept constant with +/-1%, manual voltage adjustment within +/-5% v) Frequency regulation +/- 1% (B) Diesel Engine: Adequate capacity of Diesel engine as approved by GE basing on manufacturers technical details water cooled to drive independently above alternator and after considering de-rating as per site conditions after generating and reducing power consumed by

1

-

-

... More
accessories directly coupled through flexible coupling multi cylinder multi stroke direct injection, cold starting 1500 RPM, as per relevant ISI/BS - 5514 with an overload capacity of 10% for half an hour in 12 hours continuous running complete with standard accessories all as specified and required for safe handling and operation salient features of accessories shall be as under: (i) Fly wheel with housing (ii) Cooling System: Moulded radiator with fan & belts (iii) Cooling Water Pump: Centrifugal type belt driven (iv) Exhaust System: Exhaust System complete with exhaust piping of suitable size with MS pipe light grade up to & outside and 1meter away from the enclosure, covered with asbestos rope and aluminium foil of 28 SWG complete with in the enclosure for safe exhaust without transforming vibration to the wall of the enclosure. Exhaust gas turbo charger type. Exhaust manifold, Silencer: Residual type Bellows (v) Fuel System: Fuel injection system with fuel injectors, fuel injection solenoid switch controlled by electronic governor for 1% speed /frequency regulation, Fuel filters, Fuel hoses. (vi) Lubricating Oil System: Lubricating oil filter and lubricating oil pump (vii) Air Intake System: Air intake Manifold and air cleaner dry type (viii) Governor: Electronic Governor (ix) Starting System: Electric Self-starter with maintenance free battery including battery charging alternator (x) Batteries: Batteries of maintenance free of capacity as recommended by the manufacturer complete with copper conductor multi stranded leads of suitable length from self-starter to the battery terminals complete with initial charge and initial fill of electrolyte all as

-

-

-

... More
specified and Starter gear ring Start and stop push button, Ignition key / Switch Handling and operation : Salient features of accessories shall be as under: Radiator with blower fan Corrosion inhibitor coolant Paper element filters for fuel, Lubricating oil and by pass Electronic governor controlled direct fuel injection system Fly wheel housing and fly wheel (xi) Generator Monitoring Panel: Comprising of all standard items as mentioned under this schedule or as per standard practice ignition key switch and start / stop arrangement, indications for Engine parameters, hour run meter, RPM meter, Engine oil pressure indicator, water/coolant Temperature indicator, Battery volt display. (xii) Safety Controls: Engine low lubricating oil pressure high water Temperature and over speeding of engine. (xiii) Coupling Arrangement: Flexible coupling, fly wheel to suit flexible coupling. (xiv) Accessories: AVM Pads built in enclosure and for entire unit on platform. (xv) Base Frame: Should be provided as OEM norms (C) AMF Panel: Factory made outdoor type control cubical made out of 2mm thick CRCA sheet dust and vermin proof totally enclosed with front opening of 415 volts 3 -phase 4 - wire AC 50 Hz, including powder coated, copper bus bar of one and half times the rated load of 250 KVA alternator complete with internal wiring with PVC insulated single core copper conductor multi stranded wire of 1100 Volts grade of suitable capacity, fuses, name plates consisting of 4 pole MCCBs and Contactors of capacity as recommended by the manufacturer. Detachable cable gland plates, all controls, indicators and standard microprocessor based LED/LCD display for indicating voltage, current, frequency, speed, kW, kWH, pf, temperature, bBattery voltage, etc.

-

-

-

... More
(a) Annunciation with indication lamps for: (i) Low Lubricating oil pressure. (ii) High Water Temperature. (iii) Engine over speed. (iv) Battery low voltage (b) Controls: (i) Load on Indication (ii) Load off indication (iii) Engine start push button (iv) Engine stop push button (v) Fault accept/reset push button (vi) Battery Charger: (a) Transformer (b) Rectifier (c) Resistance (d) DC Volt meter (e) DC Ammeter (f) Charger rate selector switch (D) Acoustic Enclosure: Manufactured by OEM suitable for 500 KVA DG Set. (i) NAL approved as per CPCB (ii) It shall be as per latest rules and regulations of Ministry of Environment and Forest and Pollution Control Board. (iii) The generating set batteries and control panel should be inside the enclosure. (iv) Construction Details/specification are as follows:

-

-

-

... More
(a) Outer Body: CRCA Sheet of 1.6mm thick (b) Doors: CRCA sheet of 1.6 mm thick (c) Sound Insulation: As per OEM Norms (v) The acoustic shall be composite in construction and fully assembled integral unit. (vi) The batteries shall be placed inside the enclosure beside the DG Set on a suitable insulated platform. (vii) The DG Set shall be provided with external Emergency stop push button. (viii) The enclosure should be suitably illuminated by LED Lamp fittings. (ix) The noise level should be 75 dba at 1m under free field conditions. (x) The acoustic enclosure parts shall be of powder coated after pre-treatment process. The powder coating shade should be Gen set Green. The base frame should be painted with epoxy based black shade (E) The coated rate includes excavation, removing of soft soil and PCC, cement concrete foundation, filling and mass concrete type B2 (1:2:4) using 40mm graded aggregate of suitable size for placing of DG Set complete all as specified and directed. Notes: 1. The capacity of Generator set shall be net after all due de-rating factors as per relevant ISI design. 2. Rate quoted shall be deemed to be inclusive of cable and terminations form Generator to the AMF Panel, with necessary holes to wall including making good to disturbed surfaces so as to match with the existing finishes all as specified and directed. 3. The quoted rate shall be deemed to be inclusive of first fill of oil and final successful acceptance test.

-

-

-

... More
M&L earthing complete with GI plate electrode 60cmxx60cmx6mm thick, buried directly in ground (Earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised iron earth strip 32x6mm size by means of bolts, nuts, check nuts and washers of copper all as shown in electrical plate No.3 of SSR Part-I connected to earhing test point all as specified or indicated including excavation and connected earth work in hard/dense soil, PCC 1:3:6 type C1 as in pit, 20mm dia. GI pipe medium grade for watering pipe, 15mm bore GI light grade earth lead protection pipe, and 50mm thick RCC cover slab with handle, reinforced with 10mm dia. bars in both the directions, funnel, strainer, charcoal and testing on complete all as specified and as directed by the Engineer-in-Charge. Notes: 1. Rate quoted deemed to include GI protection pipe, funnel, excavation and earth work, in soft/loose soil with PCC type C1 in bed and pit complete all as specified and as directed. 2. Earth lead up to 7.50m length is deemed to be included in the quoted rate the beyond 7.5m length will be measured and paid separately.

4

-

-

... More
CRANES:

-

-

-

... More
Supply, install, test and commissioning of electrically operated overhead travelling (EOT) crane of 2.0 Tonne capacity complete and having of 8 meters span (Approximate) with long travel distance of 35 meters with clear hook height of 4.5 meters from floor level, double box girder type with necessary steel supporting structure electric motor with micro motion control with VVVF drive and shall be operated by means of push button pendent unit from the floor and control panel and operated with pendent control moveable independent of crab position including provision of steel gantry rails for long travel for complete length and including provision of down shop Lead (DSL) and shrouded bus bar system, having the following specifications complete all as specified and as directed by the Engineer-in-Charge: (a) Hoist Speed 3.0m/min (b) Hoist Creep 0.3m/min (c) C.T Speed 7.0m/min (d) C.T Creep 0.7 m/min (e) L.T Speed 10.0m/min (f) L.T Creep 1.0m/min (g) Hook height 4.5m

1

-

-

... More
Supply, install, test and commissioning of Flame proof electrically operated overhead travelling (HOT) crane of 1.0 Tonne capacity complete and having of 8 meters span (Approximate) with long travel distance of 20 meters with clear hook height of 4.5 meters from floor level, double box girder type with necessary steel supporting structure electric motor with micro motion control with VVVF drive and shall be operated by means of push button pendent unit from the floor and control panel and operated with pendent control moveable independent of crab position including provision of steel gantry rails for long travel for complete length and including provision of down shop Lead (DSL) and shrouded bus bar system, having the following specifications complete all as specified and as directed by the Engineer-in-Charge: (a) Hoist Speed 1.0m/min (b) Hoist Creep 0.5m/min (c) C.T Speed 3.0m/min (d) C.T Creep 1 m/min (e) L.T Speed 3.0m/min (f) L.T Creep 1.0m/min (g) Hook height 2.0m

4

-

-

... More
M&L earthing complete with GI plate electrode 60cmxx60cmx6mm thick, buried directly in ground (Earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised iron earth strip 32x6mm size by means of bolts, nuts, check nuts and washers of copper all as shown in electrical plate No.3 of SSR Part-I connected to earhing test point all as specified or indicated including excavation and connected earth work in hard/dense soil, PCC 1:3:6 type C1 as in pit, 20mm dia. GI pipe medium grade for watering pipe, 15mm bore GI light grade earth lead protection pipe, and 50mm thick RCC cover slab with handle, reinforced with 10mm dia. bars in both the directions, funnel, strainer, charcoal and testing on complete all as specified and as directed by the Engineer-in-Charge. Notes: 1. Rate quoted deemed to include GI protection pipe, funnel, excavation and earth work, in soft/loose soil with PCC type C1 in bed and pit complete all as specified and as directed. 2. Earth lead up to 7.50m length is deemed to be included in the quoted rate the beyond 7.5m length will be measured and paid separately.

2

-

-

... More
M&L earth continuity conductor or main earthing lead made of galvanised iron strip 32x6mm size, fixed to wall on batten or recess or chases or burried in ground or fixed to poles or any other indicated situation for earthing etc. complete all as specified and as directed by the Engineer-in-Charge.

30

-

-

... More
AIR CONDITIONING:

-

-

-

... More
WATER-COOLED SCROLL TYPE CHILLER UNIT WITH R22/R407C/R40a REFRIGERANT

-

-

-

... More
Supply, install, commissioning and testing of Water-cooled scroll chiller, with multi- compressors, comprising of semi - hermetic/hermetic/open type compressors, DX Evaporator, shell and tube condenser, suitable expansion device, suitable for operation on R - 22 /R - 407 C/R 410a refrigerants and of following nominal capacity. (2 W + 1 S)

-

-

-

... More
scroll type chiller of nominal capacity not less than 30 TR, suitable for ambient conditions, with AHRI(Air Conditioning,heating and Refrigeration Institute) certification.(Note-:including suitable copper wire for connection and starter)

3

-

-

... More
HORIZONTAL END SUCTION LONG COUPLED TYPE CHILLED WATER PUMP WITH INSULATION

-

-

-

... More
Supply, installation, testing and commissioning of end-suction & top-discharge, non-self-priming, single-stage, centrifugal volute type pump having cast iron casing, enclosed type dynamically balanced phosphor-bronze/SS impeller, high tensile steel shaft, carbon steel stuffing box (sealed by mechanical seal), deep groove ball bearings, TEFC squirrel cage high efficiency induction motor, star/delta starter panel, base plate, mounting channel frame, accessories and fittings, viz. mechanical seal, pressure gauges, thermometers, drains, coupling, coupling guard, vibration isolation arrangement by means of spring/rubber type mounting, elastomeric thermal insulation of suitable thickness, etc. suitable for operation on 3- Phase, 415 V ± 10%, 50 Hz AC supply. (1 W + 1 S)

-

-

-

... More
Horizontal End Suction Long Coupled type pump with insulation suitable for 150 USgpm water flow rate and 45 m head.(Note-:including suitable copper wire for connection and starter)

2

-

-

... More
FRP RECTANGULER/ROUND SHAPE INDUCED DRAUGHT COOLING TOWER

-

-

-

... More
Supply, installation, commissioning and testing of induced draft top discharge counterflow type FRP cooling tower (rectangular/round bottle shape) with FRP body and base, water spray headers, cooling tower fills, fan with motor, supporting base frames, as per manufacturer's standard instructions.

-

-

-

... More
FRP Bottle shape induced draught cooling tower of 72 TR capacity(Note-:including suitable copper wire for connection and starter)

1

-

-

... More
HORIZONTAL SPLIT CASING CONDENSER WATER PUMP FOR COOLING TOWER

-

-

-

... More
Supply, installation, testing and commissioning of end-suction & top-discharge, non-self-priming, single-stage, centrifugal volute type pump having cast iron casing, enclosed type dynamically balanced phosphor-bronze/SS impeller, high tensile steel shaft, carbon steel stuffing box (sealed by mechanical seal), deep groove ball bearings, TEFC squirrel cage high efficiency induction motor, star/delta starter panel, base plate, mounting channel frame, accessories and fittings, viz. mechanical seal, pressure gauges, thermometers, drains, coupling, coupling guard, vibration isolation arrangement by means of spring/rubber type mounting suitable for operation on 3- Phase, 415 V ± 10%, 50 Hz AC supply.

-

-

-

... More
Horizontal Split Casing type pump suitable for 220 USgpm water flow rate and 25 m head.(Note-:including suitable copper wire for connection and starter)

2

-

-

... More
DOUBLE SKIN AIR HANDLING UNITS WITH 43 mm THICK CFC-FREE PUF INJECTED INSULATION PANEL HAVING 10 MICRON PRE-FILTERS

-

-

-

... More
Supply, installation, testing and commissioning of double-skin type horizontal, floor-mounted, top/side discharge air handling units having corrosion resistant extruded aluminum hollow profile with thermal break, heavy gauge galvanized steel channel base frame, 43 mm double skin panel with pressure injected CFC & HCFC free PUF with 'k' value of 0.02 W/°C m & density 40 kg/cum, pre-coated pre-plasticized galvanized outer and inner skin 0.60mm thick, air-tight casing using gaskets and self-adhesive tapes, AMCA certified energy efficient fans with double inlet double width forward or backward curved impellers for high static pressure mounted on aluminum extruded slide rail base frame, chilled water coils with combination of 6 rows deep with anti-corrosion Aluminum fins, PVC Naylon hinges & handles, view port and marine lamp, limit switch, SS-304 drain pan, 10 micron pre-filters, inspection windows/doors, mixing box and supply/return/fresh air dampers. [a] Suitable DIDW fan with AMCA certified blower having outlet velocity not exceeding 9.2 m/s [b] 4 Pole, TEFC, high efficiency, squirrel cage induction motor drive having BHP rating 20% higher than the peak capacity, suitable for 415 V ±10%, 50 Hz, 3-Phase AC power supply [c] V-belt drive assembly with pulleys, belt, guard, etc., double canvass connections with zip to discharge duct/plenum, etc. [d] 50 mm thick, washable HDPE, 90% down 10 micron pre-filters, filters, fixing framework, hinge type access doors, etc. [e] 6 row deep chilled water coil section with copper fins and copper tube tested on 21 kg/sq cm with SS sandwiched drain tray, etc. [f] 18 gauge MS CRCA duly powder coated AHU sub panel board in compartamentalised construction with incomer and outgoing feeders for AHU motor, 3-way valve actuator motor, fire damper actuator motor, etc. complete with required variable frequency drive, relays, timers, contactors, PT, push buttons, switches, internal wiring, etc.

-

-

-

... More
24000CFM; 60 TR; 75 mm WG static pressure. (CFM =LxBxHxACH(2to8)/60 (feet)(59X148X26x2/60)(Note-:including suitable copper wire for connection and starter) (For 05 Nos AHU distributed to 24000 CFM)

1

-

-

... More
STAINLESS STEEL CHILLED WATER MAKE-UP EXPANSION TANK

-

-

-

... More
S & F SS- 304 closed expansion tank of pressure rating to suit the system pressure and sized adequately to compensate for water expansion due to operating temperature variations, conforming to IS: 2825- 1969 for 'non-fired pressure vessels' complete with inter-connection piping, non-return valve, safety relief valve and pressure gauge, insulated with 50 mm thick insulation and cladded with 26 G aluminium.

-

-

-

... More
SS- 304 closed expansion tank of 1000 liter capacity

1

-

-

... More
HDPE CONDENSER WATER EXPANSION TANK FOR COOLING TOWER

-

-

-

... More
S&F HDPE expansion tank of pressure rating to suit the system pressure and sized adequately to compensate for water expansion due to operating temperature variations, conforming to IS: 2825- 1969 for 'non-fired pressure vessels' with interchangeable EPDM-BUTYL rubber membrane complete with inter-connection piping, non-return valve, safety relief valve and pressure gauge etc.

-

-

-

... More
HDPE expansion tank of 5000 liter capacity

1

-

-

... More
CONDENSER WATER PIPING

-

-

-

... More
MS ERW CLASS- C PIPE

-

-

-

... More
Supply, installation, testing and commissioning of MS ERW Class 'C' condenser water piping with all necessary fittings i.e. bends, tees, reducers, flanges, structural support, wooden blocks, air-purge valves, drain-valves, etc. as specified in particular specifications.

-

-

-

... More
150mm NB

20

-

-

... More
100 mm NB

25

-

-

... More
BUTTERFLY VALVE

-

-

-

... More
Supply, installation, testing and commissioning of PN 1.6 rated double flanged short & long body type butterfly valve designed, manufactured and tested as per IS: 13095 (1991), suitable for isolation and throttling services, having CI body & disc, SS AISI 304 disc seal, CS clamping ring and SS AISI 410 shaft and flange drilling standard end connection with accessories as specified in particular specifications.

-

-

-

... More
150 mm NB

7

-

-

... More
100 mm NB

4

-

-

... More
NON-RETURN VALVE (NRV)

-

-

-

... More
Supply, installation, testing and commissioning of PN 1.6 rated swing check type multidoor reflux valve (NRV), designed & tested as per IS: 5312-2 (1986), suitable to handle clear water having turbidity up to 5000 ppm, having CI body, door and diaphram, leaded tin bronze seat rings and flange drilling standard end connection, etc. with accessories as specified in particular specifications.

-

-

-

... More
100 mm NB

2

-

-

... More
Y STRAINER

-

-

-

... More
Supply, installation, testing & commissioning of Y-type strainer with CI/MS body, bolted cover, flanged ends, basket of brass/ bronze/ SS wire mesh complete with flanges, nuts-bolts, gaskets and flange drilling standard end connection, etc. with accessories as specified in particular specifications.

-

-

-

... More
150 mm NB

1

-

-

... More
MANUAL BALANCING VALVE

-

-

-

... More
Supply, installation, testing and commissioning of 2-way, globe type, PN 1.6 rated, balanced/high rangeability control valve as per following specification. Nominal Pressure: PN16 Temperature: -10° C to +110° C Body Material: IS:210, FG 220 CI Stem Material: ASTM A276,GR SS 410 Disc Material: Stainless steel Disc Hand Wheel: Cast Iron Leakage Rate: No visible leakage Medium Type: Water Flange Standard: ISO7005-1 (GB/T 9113) Shell Test Pressure: 24bar Seal Test pressure: 17bar

-

-

-

... More
150 mm NB

3

-

-

... More
FLOW SWITCH

-

-

-

... More
Supply, installation, testing and commissioning of paddle type water flow switch, having operating pressure 1000 kPa, withstand pressure 91750 kPa, insulation resistance over 100 Ω, withstand voltage 1500 V AC for 1 minute, contact point life of 1000 k cycles and bellows life 500 k cycles complete with control wiring and accessories, etc. as specified in particular specifications.

-

-

-

... More
Water Flow Switch 150mm

3

-

-

... More
DRAIN PIPE

-

-

-

... More
M&L for UPVC pipes (SCH-80) fittings, resistant to chemical & electromechanical corrosion, conforming to EN 1452-2, having specific gravity 1.43, shore hardness 70°C to 90° C, tensile strength 500 kg/sq.cm, bending strength 950 kg/sq.cm, modulus of elasticity 3.2 X 10 kg/sq.cm and dielectric strength 40 kV/mm complete with accessories as specified in particular specification.

-

-

-

... More
50mm dia.

12

-

-

... More
CHILLED WATER PIPING

-

-

-

... More
MS ERW CLASS- C PIPE WITH INSULATION

-

-

-

... More
Supply, installation, testing and commissioning of MS ERW Class 'C' chilled water piping with all necessary fittings i.e. bends, tees, reducers, flanges, structural support, wooden blocks, air-purge valves, drain-valves, etc. thermally insulated with elastomeric insulation of 25 mm thick with rapped water prof fabric cloth as specified in particular specifications.

-

-

-

... More
100 mm NB

40

-

-

... More
80 mm NB

30

-

-

... More
65 mm NB

25

-

-

... More
BUTTERFLY VALVE WITH INSULATION

-

-

-

... More
Supply, installation, testing and commissioning of PN 1.6 rated double flanged short & long body type butterfly valve designed, manufactured and tested as per IS: 13095 (1991), suitable for isolation and throttling services, having CI body & disc, SS AISI 304 disc seal, CS clamping ring and SS AISI 410 shaft and flange drilling standard end connection with elastomeric thermal insulation of suitable thickness and accessories as specified in particular specifications.

-

-

-

... More
100 mm NB

4

-

-

... More
80 mm NB

7

-

-

... More
65 mm NB

2

-

-

... More
NON-RETURN VALVE (NRV) WITH INSULATION

-

-

-

... More
Supply, installation, testing and commissioning of PN 1.6 rated swing check type multidoor reflux valve (NRV), designed & tested as per IS: 5312-2 (1986), suitable to handle clear water having turbidity up to 5000 ppm, having CI body, door and diaphram, leaded tin bronze seat rings and flange drilling standard end connection, etc. with elastomeric thermal insulation of suitable thickness and accessories as specified in particular specifications.

-

-

-

... More
65 mm NB

2

-

-

... More
Y STRAINER WITH INSULATION

-

-

-

... More
Supply, installation, testing & commissioning of Y-type strainer with CI/MS body, bolted cover, flanged ends, basket of brass/ bronze/ SS wire mesh complete with flanges, nuts-bolts, gaskets and flange drilling standard end connection with elastomeric thermal insulation of suitable thickness and accessories as specified in particular specifications.

-

-

-

... More
100 mm NB

2

-

-

... More
MANUAL BALANCING VALVE WITH INSULATION

-

-

-

... More
Supply, installation, testing and commissioning of 2-way, globe type, PN 1.6 rated, balanced/high rangeability control valve as per following specification. Nominal Pressure: PN16 Temperature: -10° C to +110° C Body Material: IS:210, FG 220 CI Stem Material: ASTM A276,GR SS 410 Disc Material: Stainless steel Disc Hand Wheel: Cast Iron Leakage Rate: No visible leakage Medium Type: Water Flange Standard: ISO7005-1 (GB/T 9113) Shell Test Pressure: 24bar Seal Test pressure: 17bar

-

-

-

... More
80 mm NB

3

-

-

... More
3-WAY TEMPERATURE CONTROL VALVE WITH INSULATION

-

-

-

... More
Supply, installation, testing and commissioning of CI 3-way mixing valve, suitable for operation up-to 10 bar, with electronically operated actuator for AHUs. Water flow through the valve shall be regulated by rotation of brass slipper between the main and the bypass ports; it shall be possible to manually rotate the brass slipper through 360° and interchange the main and the common ports, to facilitate installation at site. All internals of the valve shall be rust-proof and the 'O' ring shall be of elastomeric insulation. The valve actuator shall be of electronic type with DC motor, the actuator's angle of rotation shall be 90°, it shall be without any limit switches and shall be overload-proof. It shall have an indicator to indicate the position and push-button to disengage the gear train for manual operation. All complete complete with elastomeric thermal insulation of suitable thickness as specified in particular specification.

-

-

-

... More
100 mm NB

1

-

-

... More
WATER FLOW SWITCH WITH INSULATION

-

-

-

... More
Supply, installation, testing and commissioning of paddle type water flow switch, having operating pressure 1000 kPa, withstand pressure 91750 kPa, insulation resistance over 100 Ω, withstand voltage 1500 V AC for 1 minute, contact point life of 1000 k cycles and bellows life 500 k cycles complete with elastomeric thermal insulation of suitable thickness, control wiring and accessories, etc. as specified in particular specifications.

-

-

-

... More
Water Flow Switch 80mm

3

-

-

... More
BALL VALVE

-

-

-

... More
20 mm NB

13

-

-

... More
AUTO-AIR-VENT

-

-

-

... More
Supply, installation, testing and commissioning of automatic air-vent valve with Brass OT 58 body and cover, polyacetal lever, high density expanded polyethylene float, EPDM rubber plug, stainless steel spring, polyamide capm etc. suitable for maximum operating pressure of 16 bar and maximum operating temperature 115° C respectively, installed on all high points in the water piping system to automatically remove the trapped air, installed on all high points in the water piping system to automatically remove the trapped air, all complete as specified in particular specifications.

-

-

-

... More
Automatic air-vent having 19 mm end connections

3

-

-

... More
TEMPERATURE GAUGE

-

-

-

... More
Supply, installation, testing and commissioning of glycerin filled bimetallic thermometer in compliance to EN 13190, having standard range 0° C to 60° C up to 400° C, IP 67 protection, bimetal coil sensing element, accuracy class 1 as per EN 13190, stainless steel casing, direct bottom mounted, SS- 304 case and bayonet type bezel, SS- 316 stem and connection, aluminum dial (white background with black marking) & pointer (black colour micrometer with zero adjustable), toughened glass window, neoprene filling plug and gasket complete with accessories, etc. as specified in particular specifications.

-

-

-

... More
Temperature gauge of 150 mm dial size for temperature range 0° C to 100° C

12

-

-

... More
PRESSURE GAUGE

-

-

-

... More
Supply, installation, testing and commissioning of glycerin filled pressure gauge in compliance to EN837-1, having standard range 15 to 0 psi and 16 psi to 10000 psi, IP 67 protection, accuracy class ±1.6% of FS, stainless steel casing and TIG argon welded socket to case, direct bottom mounted, SS- 304 case and bayonet type bezel, SS- 316 bourdon, socket, SS dial (white background with black marking) & pointer (black colour micrometer with zero adjustable), polycarbonate glass window, neoprene blow off disc and filling plug, silicon gasket complete with accessories, etc. as specified in particular specifications.

-

-

-

... More
Pressure gauge of 100 mm dial size for pressure range 0 psi to 200 psi

16

-

-

... More
AIR DISTRIBUTION

-

-

-

... More
GALVANIZED STEEL SHEET DUCTING

-

-

-

... More
Supply, installation, testing and commissioning of pre-fabricated galvanized steel sheet (G.S.S.) square/rectangular ducting for supply/return air, fabricated from galvanized steel sheet, having zinc coating of 160 gm/sq m total on both sides complete with gaskets, elbows, splitters, vanes, supports etc. as per IS: 655/1963 with required scaffolding work to install the ducts at site

-

-

-

... More
24 G (MS angle flanges)

150

-

-

... More
22 G (MS angle flanges)

80

-

-

... More
20 G (MS angle flanges)

72

-

-

... More
FIRE DAMPER

-

-

-

... More
Supply, installation, testing and commissioning of fire damper complete with smoke detector/thermister, fusible link etc. and actuator as required for operation. The fire dampers shall be spring activated on melting of fusible link having melting point 67.13° C. The fire damper shall be located in the SA/RA ducts, at all fire rated crossovers (shafts, walls, etc.). The control panel shall be located in such a way that the reset can easily be done. These combination smoke and fire dampers shall be interlocked with the building management system for the fire detection or HVAC and shall trip/close in the event of fire/smoke in the respective zone. Fire damper shall be tested as per ULL- 555 and certified by CBRI. The fire-damper shall be of at least 120 minutes fire-rating as per the approved particular technical specifications and shall meet the following design criteria: [a] Bare fire dampers with 400 mm sleeve [b] Control panel actuator, including electrical spring type actuator, remote indication of the fire damper position. [c] Interconnection wire for the fire detection & alarm system with the AHU and the smoke dampers [d] Sealing any openings around the sleeve of the fire dampers with approved fire sealant as per the recommendations of the manufacturer and specifications.

-

-

-

... More
Motorized, spring return type, combination fire and smoke damper

1

-

-

... More
Control panel actuator, including electrical spring type actuator, remote indication of the fire damper position.

5

-

-

... More
ACOUSTIC INSULATION

-

-

-

... More
M&L for duct insulation with resin bonded fibre glass wool roll of density 24 kg/Cum, with factory laminated aluminium vapour barrier, thickness of insulation as specified and including the following: (a) M&L for cleaning the duct surface (to be insulated ) by scrapping carefully with wire brush etc. to make the surface completely free of millscale, dirt, dust, grease and other foreign materials, taking special care so that all duct joints are sealed against any leakage. (b) M&L for applying rubber based adhesive CPRX compound. (c) M&L for sealing of all longitudinal joints and circular overlaps with and including Aluminium foil tape 50 mm wide, to make the insulation leakproof. (d) M & L for securing the insulation with and including mechanically fastened nylon/' steel straps of size 12 mm/50 mm at maximum intervals of 1.2 mtr.

-

-

-

... More
50 mm thick

210

-

-

... More
THERMAL INSULATION

-

-

-

... More
M&L for underdeck insulation for metal roof with bonded fibre glass wool of density 24 Kg/Cum, 50 mm thick, suitably factory laminated with aluminium foil backed up by scrim and kraft paper (FSK), facing with 50 mm projection for overlap and butting comprising of the following:- (insulating material shall conform to BS - 476, Part 4,5, 6 & 7):-“(a) Supply and fix 6 mm dia M S rods between purlins suitably for supporting the required thickness of insulation material beneath the metal roof.“(b) Supply and fix 22 SWG GI wires supports for insulation.“(c) Supply and fix chicken wire mesh 12.5 mm x 22 SWG of hexagonal construction below the insulation for supporting the same."All complete as specified in particular specifications.

210

-

-

... More
SA/RA DIFFUSERS/ GRILLES/LOUVERS

-

-

-

... More
Supply, installation, testing & commissioning of removable supply/ return air diffusers/grilles of extruded aluminum sections duly powder coated with volume control damper.

-

-

-

... More
4-way SA/RA diffusers/grilles/louvers with volume control damper

50

-

-

... More
18 G galvanized sheet steel volume control duct damper

50

-

-

... More
Supply, installation, commissioning and testing of AC Plant Room LT Panel Board (3 X 30 TR). BUSBAR:- [i] Copper busbar of rated capacity 800 A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connection- 01 Set (of 04 busbars) INCOMING :-[ii] LED phase indicators (Yellow, Blue, Red)- 01 Set [iii] Digital voltmeter 0-500 V with selector switch flush mounting square type- 01 Nos. [iv] Digital ammeter 0- 250 A with selector switch flush mounting square type with suitable CTs - 01 Nos. [v] 500 A, 415 V, Ics = Icu = 36 kA, 50 Hz FP MCCB with adjustable overload settings (0.40- 1 X In), adjustable short-circuit settings (1.5- 10 X Ir) and microprocessor based trip unit- 1 Nos. OUTGOING [i] 160 A, 415 V, Ics = Icu = 25 kA, 50 Hz FP MCCB with adjustable overload settings (0.40- 1 X In), adjustable short-circuit settings (1.5- 10 X Ir) and microprocessor based trip unit- 3 Nos. [ii] Fully automatic star/delta starter, suitable for condenser water pump, complete with contactors, push button, LED type indicators, auto/manual selector switch, overload protection, current sensing type single phase preventer complete with all accessories and wiring etc- 2 Nos [iii] Fully automatic star/delta starter, suitable for chilled water circulation pump, complete with contactors, push button, LED type indicators, auto/manual selector switch, overload protection, current sensing type single phase preventer complete with all accessories and wiring etc- 2 Nos [iv] Fully automatic star/delta starter, suitable for cooling tower pump, complete with contactors, push button, LED type indicators, auto/manual selector switch, overload protection, current sensing type single phase preventer complete with all accessories and wiring etc- 1. Nos

1

-

-

... More
POWER CABLES

-

-

-

... More
M & L for IS 694 marked, FIA/TAC approved stranded aluminium/copper conductor (as per IS 8130), XLPE insulated, extruded PVC type ST-2 (as per IS: 5831) sheathed, single layer of galvanized steel flat strip armoured cable of 1.1 kV grade, conforming to IS 7098 (Part-2), including cable termination and cable glanding.

-

-

-

... More
Aluminum Conductor, 120 sq mm, 3.5 core

25

-

-

... More
Aluminum Conductor, 95 sq mm, 3.5 core

25

-

-

... More
Aluminum Conductor, 35 sq mm, 3.5 core

30

-

-

... More
Aluminum Conductor, 25 sq mm, 3.5 core

30

-

-

... More
EARTHING

-

-

-

... More
M & L for earthing complate with copper earth plate electrode of 60 cm X 60 cm X 3.15 mm size , buried directly in ground (earth pit not less than 2.25 m deep below ground level ) with top edge of the plate not less than 1.5 m below normal ground level, connected to 20 mm X 3 mm copper strip as earthing lead,by means of bolts , buts, check nuts and washer of galvanised iron or steel ,connected to earthing test point, including testing on completion.

4

-

-

... More
M & L for earth contuinity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 20 mm X 3 mm copper strip

75

-

-

... More
S & F Cast iron work grade FG 150, Articles exc 5 kg each unmachined, in brackets, gully traps, gratings, railing, frames, manhole covers, fire and soot doors, dampers, stop valve boxes, gate stops, parts of ranges, balusters and similar articles as specified.

6.57

-

-

... More
Setting in cement mortar 1:3 and flaunching with cement concrete 1:2:4 type B-l cast iron manhole covers and frames, medium duty, any type and size as specified.

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.