Military Engineer Services Tender
To know what Andhra Pradesh government has posted about any AP etender, Bidassist helps us to get a one-stop platform where a registered bidder can have access to the details on each and every eprocurement tender. There is no need to provide the details on the AP E-procurement website i.e. https://www.apeprocurement.gov.in as BidAssist helps us find the specific etender we're looking for. BidAassist has collated each and every Eproc Andhra Pradesh Tender on its website.
Military Engineer Services - MES Tender
Civil And Construction
Building Construction
Eprocure
Opening Date9 Dec 2024
Closing Date6 Jan 2025
Tender Amount₹ 9,90,000
Costs
EMD
₹ 19,800Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_687714_1Bid Award Id
ViewTender No
AGE I R AND D NSTL VIZAG 8559Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://defproc.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Dismantling aluminium/ Gypsum partitions,and false ceiling etc. including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge.
87
-
-
... More
Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all Tsections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by
Engineer-in-Charge. Note :- Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/opening (cut outs) having area less than 0.30 sqm.The calcium silicate ceiling tile shall have NRC value of 0.50 (Minimum), light reflection 85%, non- combustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity 0.043 w/mK
87
-
-
... More
Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure above plinth level up to floor five level in cement mortar 1:6 (1 cement : 6 coarse sand) : With F.P.S.(non modular) bricks
5
-
-
... More
M & L 12 mm thick cement plaster of mix : 1:6 (1 cement: 6 fine sand) complete all as specifid and as directed by Engineer-in-Charge.
40
-
-
... More
M & L for newly plastered internal wall and applying two coats of white cement based putty including sand papering the puttied surfaces to form an even and smooth surface and applying two coats of plastic emulsion over a coat of interior primer complete all as specified and directed
40
-
-
... More
Dismantling tile work in floors and roofs laid in cement mortar including
stacking material within 50 metres lead. For thickness of tiles 10 mm to 25 mm
10
-
-
... More
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Glazed Vitrified tiles Matt/Antiskid finish of size Size of Tile 600 x 600 mm
2
-
-
... More
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps
and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm,including pointing in white cement mixed with pigment of matching shade complete.
8
-
-
... More
Taking down old point wiring complete for light/fan/socket(5/15 Amps) bell point etc complete with all light fittings accessories, such as switch sockets 5/15 Amps, ceiling rose etc including making good to the disturbed surface to match with the existing complete all as specified and directed by Engineer-in-Charge.
50
-
-
... More
Taking down old DBs with MCCB , MCBs of any size and capacity & making good to the disturbed surface to match with the existing complete all as specified and directed by Engineer-in-Charge.
7
-
-
... More
Taking down old sub main wiring/cable of any size and capacity including making good to the disturbed surface to match with the existing complete all as specified and directed by Engineer-in-Charge.
135
-
-
... More
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
15
-
-
... More
Supplying and fixing 3 pin 5/6 A modular socket outlet as required.
2
-
-
... More
Supplying and fixing 15/16 A modular socket outlet as required.
17
-
-
... More
Supplying and fixing modular bell push on the existing modular plate & switch box including connections but excluding modular plate etc. as required
1
-
-
... More
Supply & fixing of call bell/buzzer complete all as specified and directed.
1
-
-
... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required for light point ,5 Amps socket,16 Amps power socket & sub main wiring.a) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire (power Circuit)
60
-
-
... More
(b) 2 X 6 sq. mm + 1 X 6 sq. mm earth wire (AC Circuit)
65
-
-
... More
(c) 2 X 10 sq. mm + 1 X 6 sq. mm earth wire (Main Circuit)
40
-
-
... More
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete.
1
-
-
... More
Supply and fixing LED luminaire 600 mm x 600 mm,36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable sizecomplete all as specified and directed by Engr-in-charge.Make :Crompton LCTRH-36-CDL
8
-
-
... More
S & F in repair MCB DB double door SPN 12 Way with 200 Amps rated copper bus bar complete all as specified and directed.
1
-
-
... More
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning.(i) SP 6 To 32 AMP
12
-
-
... More
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning.(i) SPN 32 AMP
3
-
-
... More
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required
2
-
-
... More
Supply and fixing exhauat fan of 250 mm sweap plastic 1350 RPM body normal duty all as specified and directed.
1
-
-
... More
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
25
-
-
... More
M& L for taking down the split AC indoor unit from false ceiling/wall carefully and making good to the disturbed surface to match with the existing,deposite in MES store yard and after completion work refixing the indoor units at their existing/new loaction complete electrical connection as per earlier make it operational including brazing work,insulation,required copper tube & gas charging if required complete all as specified and directed by Engr-in-charge.
2
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements