Military Engineer Services Tender
To know what Andhra Pradesh government has posted about any AP etender, Bidassist helps us to get a one-stop platform where a registered bidder can have access to the details on each and every eprocurement tender. There is no need to provide the details on the AP E-procurement website i.e. https://www.apeprocurement.gov.in as BidAssist helps us find the specific etender we're looking for. BidAassist has collated each and every Eproc Andhra Pradesh Tender on its website.
Military Engineer Services - MES Tender
Civil And Construction
Building Construction
Eprocure
Opening Date14 Jun 2024
Closing Date3 Sep 2024
Tender Amount₹ 30,00,000
Costs
EMD
₹ 60,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_659820_1Tender No
8319/GEND/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Surface excavation n.exc 30 cm deep and averaging 15cm deep and getting out in soft/loose soil
90
-
-
Excavation over areas, n exc 1.5 m deep and getting out soft/loose soil
124
-
-
Removing excavated soil exc. 250m but n.exc 500m and depositing where directed.
137.5
-
-
SCHEDULE 'A' Part -III ( INTERNAL WATER SUPPLY)
-
-
-
Supplying and laying of CPVC pipes of 25mm dia SDR 11 & Plain CPVC SDR 11 fittings in trenches complete all as specified.
25
-
-
Supplying and laying of CPVC pipes of 20mm dia SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified.
15
-
-
Supplying and laying of CPVC pipes of 16mm dia SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified.
7
-
-
Supply and fixing of 20mm dia ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed or brass ferrule (min weight 210 gms) complete all as specified and as directed.
1
-
-
S&F gunmetal gate valve of 20mm dia with iron wheel head screwed both ends for iron pipe and fixed complete all as specified and as directed.
2
-
-
S & F 15 mm bore pillar taps, Cast Copper alloy, with capstan heads, chromium plated, screwed down high pressure with or without lettered Hot or Cold with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and as directed.
1
-
-
S & F 100 mm to 125 mm bore mild steel chromium plated grating fixed on floor trap/Nahni trap in CM 1:6 complete all directed.
4
-
-
S & F 15 mm bore chromium plated bib taps, cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as specified.
3
-
-
S & F 15 mm bore Stop valves, cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions complete all as specified and as directed.
3
-
-
S&F CP shower rose 75 mm dia with or without Swivel joints any size, including fixing to steel pipe or union fixed complete all as specified and as directed.
1
-
-
SCHEDULE 'A' Part -IV ( INTERNAL ELECTRIC SUPPLY )
-
-
-
M&L for point wiring with 1.5sqmm PVC insulated unsheathed multistranded copper cable of FRLS grade with one run of 1.5 sqmm PVC insulated copper cable as earth continuity drawn in and inciluding concealed/semi concealed PVC conduit not less than 20mm dia including for mounting switches/Sockets, accessories such as spacers, saddles, junction boxes, metal box & cover plate of switch board for one light / fan point / Bell point / 5 Amps Socket same board controlled by one switch complete
Note- The PVC Conduit is to be Concealed in wall through cutting,Chassing,Pining in making good surfacing where required and poining in cement mortar and making good for same unit rates are inculded for same
8
-
-
Description all as per item No. 15 above but for 5/6Amp switch socket out let, independent board complete all as specified
5
-
-
Description all as per item No. 15 above but for 15/16Amp switch socket out let, independent with 4.0sqmm copper cable of PVC insulated, unsheathed, multi stranded and 4.0 Sqmm for earth continuity conductor, complete all as specified
2
-
-
Description all as per item No. 15 above but for one light point controlled by two 2 way switches with cables 1.5 Sqmm size copper cable of PVC insulateds, unsheathed, mutti stranded and 4 sqmm for earth continuity conductor complete all as specified
2
-
-
Supply and fixing Modular switch 1 way 6A, 1 module single pole complete all as specified and directed by Engr-in-charge.
13
-
-
Supply and fixing Modular switch 1 way 16A, 1 module single pole complete all as specified and directed by Engr-in-charge.
2
-
-
Supply and fixing Modular switch 2 way 6A, 1 module single pole complete all as specified and directed by Engr-in-charge.
4
-
-
Supply and fixing ceiling rose surface bake lite 65 x 30 mm with 3 terminals complete all as specified and directed by Engr-in-charge.
8
-
-
Supply and fixing of Socket, 6A - 2/3 pin combined 2 module, 230 volt, multipurpose, complete all as specified.
7
-
-
Supply and fixing of Socket 15A/16A - 2/3 pin combined 2 module, 230 volt, multipurpose, complete all as specified.
2
-
-
Supply and fixing of modular Fan step regulator, 120W - 2 module complete all as specified.
2
-
-
S & F 4 feet long LED batten tube light fittings, surface and wall mounted with aluminium housing and integrated electronic driver of minimum 1800 lumens (18-20 Watt) of cool white / warm comprising of batten with all accessories internally prewired and connecting up with twin core twisted copper conductor cable of suitable size complete all as specified and as directed by the Engineer-in-Charge.
4
-
-
S & F 2 feet long LED tube light fittings, surface and wall mounted with aluminium housing and integrated electronic driver of minimum 900 lumens (9 Watt) of cool white / warm comprising of batten with all accessories internally prewired and connecting up with twin core twisted copper conductor cable of suitable size complete all as specified and as directed by the Engineer-in-Charge.
2
-
-
S & F LED light fitting 9/10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed by the Engineer-in-Charge.
2
-
-
Supply and fixing of Factory made sheet metal enclosure for DBs (Fixed flush to the wall), SPN, 240 volt, 4 Way, IP-42 protection with 200 Amp rated bus bar and 1.5 Sq. mm copper PVC sheathed cable for earth continuity and suitable for having MCB’s , complete all as specified.
1
-
-
Supply and fixing of MCB 6 to 32Amp, 240 Volt, SP, breaking capacity 10 KA 'C' series, complete all as specified.
2
-
-
Supply and fixing of MCB 6 to 32Amp, 240 Volt, SPN, breaking capacity 10 KA 'C' series, , complete all as specified.
1
-
-
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC), complete all as specified and directed.
2
-
-
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers complete all as specified and directed.
1
-
-
Submain wiring with 2 runs of 2.5 sqmm PVC insulated unsheathed coper cable mutlistrand 1100 V of FRLS grade drawn in surface/ concealed PVC conduit not less than 25mm dia and one run of PVC insulated unsheathed 2.5 sqmm as earth continuity conductor drawn in PVC conduit with accessories complete including taking out old unsv submain wiring complete and making good the disturbed surfaces complete all as specified and directed. Note : 3 runs of 2.5 sqmm of cable with conduit will be measured as one unit i.e RM
60
-
-
Submain wiring with 2 runs of 6 sqmm PVC insulated unsheathed coper cable mutlistrand 1100 V of FRLS grade drawn in surface/ concealed PVC conduit not less than 25mm dia and one run of PVC insulated unsheathed 6 sqmm as earth continuity conductor drawn in PVC conduit with accessories complete including taking out old unsv submain wiring complete and making good the disturbed surfaces complete all as specified and directed. Note : 3 runs of 6 sqmm of cable with conduit will be measured as one unit i.e RM
20
-
-
SCHEDULE 'A' Part -V ( EXTERNAL WATER SUPPLY )
-
-
-
Supply and lay pipe galvanized, “Medium class”, including fittings 25 mm (1.0'') dia in trench/ surface/walls etc and complete all as specified and directed
125
-
-
Supply and lay pipe galvanized, “Medium class”, including fittings 50 mm (2.0'') dia in trench/ surface/walls etc and complete all as specified and directed
20
-
-
Supply and fix gun-metal gate valves, with iron wheel, head, screwed both ends of size 25mm complete all as specified and directed.
20
-
-
Cutting or screwing from existing GI/CI tubing of any size for alteration or additions suitable size for 25 mm dia complete all as specified and directed
1
-
-
Re-routing of existing GI/CI tubing of size upto 100 mm dia by disconnecting all connections and refixing including required tee, bends , elbows etc complete all as specified and directed
50
-
-
Excavation in trenches not exc.1.5m wide and not exceeding 1.5m in depth and getting out in hard/dense soil for laying of cable complete all as specified.
18
-
-
Returning, filling in, including spreading, levelling, watering and well ramming in layer not exceeding 25 cm thick complete all as specified
17.65
-
-
Removing excavated surplus soils meterial not exc.50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified.
0.35
-
-
SCHEDULE 'A' Part -VI ( EXTERNAL ELECTRIC SUPPLY )
-
-
-
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sqmm 4 core.
150
-
-
Excavation in trenches not exc.1.5m wide and not exceeding 1.5m in depth and getting out in hard/dense soil for laying of cable complete all as specified.
32.4
-
-
Material and labour for natural river sand as cushioning of cables, including spreading and punning down complete all as specified and directed by Engineer in charge. Note : punned thickness shall be measured for payment purpose
15
-
-
Supply and laying in trenches old size bricks subclass B complete all as specified & directed
1
-
-
Returning, filling in, including spreading, levelling, watering and well ramming in layer not exceeding 25 cm thick complete all as specified
22.7
-
-
Removing excavated surplus soils meterial not exc.50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified.
9.7
-
-
Supply and fixing LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp.
4
-
-
Supply and fixing rotatable LED search light 200W, 230V, AC, High intensity and weatherproof having high effiency SS/G reflectors and range of 500m, complete includig conecting up with twin core twisted coper conductor cable , completw all as specified and as directed.
1
-
-
Re-routing of existing XLPE Cable of any size between 25-95 Sqmm by disconnecting all connections and refixing including other accessories complete all as specified and directed
50
-
-
M&L Earthing complete with GI plate electrode 600x600x6mm thick, buried directly and preferably vertically in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, filled with alternate layer of coal and charcoal ,connected with Galvanize earth wire 4 mm dia by means of bolts, nuts, check nuts and washers of copper all as shown in electrical plate No 5, connected to earthing with DBs all as specified including earth work and excavation in any type of soil, PCC 1:3:6 type C1 chamber & RCC 1:2:4 type B1 cover 40mm thick, with 8mm dia steel deformed (TMT bars) reinforcement at 150mm c/c both ways, 20mm dia GI medium grade pipe for watering , water funnel complete all as specified and testing on completion.
1
-
-
SCHEDULE 'A' Part -VII ( ROAD/PATH/CULVERT )
-
-
-
M&L for Excavating over areas of soft loose soil n exc 1.5 m deep and getting out
25
-
-
M&L for Removing excavated soil material exc 250 mtr but n exc 500 mtr and depositing where directed.
25
-
-
M & L for hardcore of gauge not exceeding 63 mm of broken granite stone, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface.
15
-
-
M&L for PCC (1:3:6) type C2 using 40 mm graded stone aggregate as in fdn , filling & mass concrete complete.
10
-
-
M&L for sand filling under floors of thick including water and consolidation all as directed.
7.5
-
-
M/L for machine pressed precast conctete inter locking paver block any shape ans size conforming to IS-15658-2006 of 80mm thickness M-40 grade with grey cement no pigment all as specified and directed by manufacturer instructions.
100
-
-
M & L for Plain Cement Concrete Type C1, 1:3:6 (using 20 mm graded granite stone aggregate) cast in situ in lintels up to 1.5 M span, cills and other similar bands, plinth courses, parapets, copings, bed plates, bonds and the like including weathering,
1.5
-
-
SCHEDULE 'A' Part -VIII ( SEWAGE DISPOSAL )
-
-
-
Excavation in trenches, not exceeding 1.5 M wide and not exceeding 1.5 M depth and getting out in soft/ loose soil.
6.05
-
-
M & L precast cement concrete block masonry with solid block type C1 (1:3:6), built in cement mortar 1:6 all as specified.
2.9
-
-
M & L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar (1:4) and finished even and fair without using extra cement including mixing of water proofing compound wherever required as per manufacturers instructions (WPC shall be measured & paid separately).
17.16
-
-
Supply only liquid water proofing compound of approved quality.
3
-
-
M&L for Plain Cement Concrete Type C1 1:3:6 (using 20 mm graded stone aggregate) cast in situ in cills and other similar bands, plinth courses, parapets, copings, hold fast ,bed plates and the like including use and waste of form work,weathering, slightly rounded or chamfered angles and throating as specified and directed.
0.2
-
-
M&L for cement concrete Type D2 1:4:8 (40mm graded aggregate) in foundations, filling and mass concrete.
0.5
-
-
M&L for 150mm dia RCC Hume pipe with one end socketed, class NP3, laid in trenches & jointed in CM (1:1) complete all as specified and directed
42
-
-
M&L for PCC (1:4:8) type D-2 using 40mm graded crushed stone aggregate in concrete flooring to drain pipes including packing under hauching against the sides of pipes after they are laid and tested for 150mm bore pipe complete all as specified and directed.
40.8
-
-
M&L for Precast cement concrete 1:2:4, type B1 (Using 20 mm graded stone aggregate) in cover slabs,shelves and similar articles with plain faces and set in cement mortar 1:4(Note : Reinforce shall be measured & paid separately)
0.27
-
-
M&L for Mild steel TMT bars 10 mm dia., and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips.
48.87
-
-
Removing Excavated soils exceeding 250m but not exceeding 500 M and depositing where directed at a level not exceeding 1.5 M above the starting point.
3.85
-
-
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm.
2.21
-
-
Cutting into existing manholes for connecting new drains pipe (150 mm dia pipe) making good to pipe and rendering, cutting out existing bencing for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B1 smooth finished, & reforming benching as required.
2
-
-