Military Engineer Services Tender
To know what Andhra Pradesh government has posted about any AP etender, Bidassist helps us to get a one-stop platform where a registered bidder can have access to the details on each and every eprocurement tender. There is no need to provide the details on the AP E-procurement website i.e. https://www.apeprocurement.gov.in as BidAssist helps us find the specific etender we're looking for. BidAassist has collated each and every Eproc Andhra Pradesh Tender on its website.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date15 Jan 2025
Closing Date12 Feb 2025
Tender Amount₹ 1,37,60,000
Costs
EMD
₹ 2,12,000Document Cost
₹ 1,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_689139_1Tender No
82495/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Note : The Transformers shall also be provided with following Terminal Arrangement & Fittings and quoted rate is deemed to be included for the same:
Terminal Arrangement:
[a] HV & LV Side: Cable Box
[b] Quad furcating cable box with five compression glands for PVC Cable and One additional neutral terminal shall be brought out separately for earthing purpose on LV Side.
[c] First filling of new and unused Transformer Oil [IS – 335 Marked], filtered and tested up to 60KV dielectric strength at 2.5mm air gap between testing electrodes. Certification of dielectric strength shall be submitted by the Contractor after filling the oil. Transformer Oil shall be got tested by APEPDCL.
[d] Apart from routine tests mentioned in these tender documents and relevant IS, pre-commissioning inspection of Transformer shall be carried out by Senior Electrical Inspector / Electrical Inspector.
[e] All necessary arrangemnents with devices for measuring the temperature of core winding and oil.
[f] Provision of brick masonry platform for transformer(overall size 2.0mx2.0m, 1.5m height above ground level and 0.60m below ground level with brickwork using flys ash bricks in CM 1:6, foundation 100mm thick in PCC 1:4:8, type D-2 and providing PCC flooring 40mm thick in PCC 1:2:4, type B-1 over sub base 75mm thick in PCC 1:4:8 over approved earth filling and rendering 15mm thick in CM 1:4 on brick masonry surfaces and applying three coats of white wash including necessary earth and excavation complete all as directed.
-
-
-
... More
M & L for lifting, handling of the transformer upto 750 KVA from sub station and shifting to new sub station including disconnecting electrical connections and again refixing complete with electrical connections complete all as directed by the Engineer-in-Charge.
5
-
-
... More
M & L for lifting, handling of the DG set of capacity upto 60 KVA from sub station and shifting to new sub station including disconnecting electrical connections and again refixing complete with electrical connections including making platform and concrete work complete all as directed by the Engineer-in-Charge.
1
-
-
... More
M & L for shifting of existing Ring main unit [RMU] of 630 Amps capacity from sub station to another sub station including disconnecting electrical connections including lifting, ltransportation charges and reinstalling in true alignment with provision of PCC platform of suitable size including connecting of cables, testing and commissioning complete all as directed by the Engineer-in-Charge.
3
-
-
... More
M & L for dismantling of existing of LT panel of any description with all components by disconnecting electrical connections and removing PCC base from existing position and reinstalling the panel in new location including making all cable and electrical connections and PCC platform as required complete all as directed by Engineer-in-Charge.
7
-
-
... More
M & L for Provision of brick masonry platform of size 2.0mx2.0mx1.80m with brickwork using flys ash bricks in CM 1:6, top finished with 100mm thick in PCC 1:2:4, type B-1 over sub base 75mm thick in PCC 1:4:8, type D-2 over approved earth filling and rendering 20mm thick in CM 1:6 on brick masonry surfaces and applying three coats of white wash including necessary earth and excavation complete all as directed.
3
-
-
... More
Supplying, Installing, Commissioning and Testing of CPRI Prototype tested, Factory made, Platform Mounted, Dust and Vermin proof LT Cubical Panel Board, Compartmentalised, Outdoor type, fabricated with 3.15mm thick CRCA Sheet and shall be given pre-treatment for degreasing, phosphatising etc. in seven tank process and shall be powder coated with RAL7035 coat with matt finish after due preparation of surfaces. The panel shall consists of 800 Amps rating TPN bus bars of high conductivity Aluminium and shall be provided with colour coded heat shrinkable sleeves mounted on porcelain/ SMC insulator supports, suitable double Compression Copper Cable Glands and panel shall be provided with separate compartments for each switch, with gland plates, lifting hooks, shutter type ventilating louver at both top & bottom duly internally secured with wire mesh, with suitable internal wiring with copper cable of suitable size etc with double stud hinged door, front openable with locking arrangement including interlocking with switch gears and to withstand short circuit fault level of not less than 100KA and degree of protection shall be IP 54. The panel shall be fixed with angle iron frame made of angles of size 75x75x8mm at Corners and ISMC of suitable size for base, embedded 600 mm below ground level in PCC 1:2:4, Type B–1 using 20mm grade stone aggregate, 600 mm above ground level complete including connecting up with existing incoming and outgoing cables, dismantling old panel board etc. and comprising the following:-
1
-
-
... More
[a] ACB, 1250 Amps, FP, 50 KA, 415 Volts, 3 Phase, AC, 50 Hz, Manual draw out type with microprocessor release – 02 No. [Incoming]
[b] Bus coupler breaker (ACB) panel 4 Pole, 415 Volts manual drawout type with microprocessor release of capacity 1250 Amps - 01 No
[c] Outgoing ACB 4 Pole, 800 Amps 36 KA, 415 Volts, 50 Hz - 01 No
[d] Outgoing MCCB 4 Pole, 400 Amps 36 KA, 415 Volts, 50 Hz - 02 Nos
[e] Outgoing MCCB 4 Pole, 250 Amps 16 KA, 415 Volts, 50 Hz - 02 Nos
[f] Outgoing MCCB 4 Pole, 160 Amps 16 KA, 415 Volts, 50 Hz - 02 Nos
[g] Digital intelligent Panel meter to measure voltage, current, frequency, power factor, KWH, etc with all connected CTs - 02 Nos
[h] Aluminium Bus bar for 3 phase & neutral supply
[j] Colour Coded LED Phase Indicating Lamps for each Phase – 10 Sets.
-
-
-
... More
Supplying, Installing, Commissioning and Testing of CPRI Prototype tested, Factory made, Platform Mounted, Dust and Vermin proof LT Cubical Panel Board, Compartmentalised, Outdoor type, fabricated with 3.15mm thick CRCA Sheet and shall be given pre-treatment for degreasing, phosphatising etc. in seven tank process and shall be powder coated with RAL7035 coat with matt finish after due preparation of surfaces. The panel shall consists of 800 Amps rating TPN bus bars of high conductivity Aluminium and shall be provided with colour coded heat shrinkable sleeves mounted on porcelain/ SMC insulator supports, suitable double Compression Copper Cable Glands and panel shall be provided with separate compartments for each switch, with gland plates, lifting hooks, shutter type ventilating louver at both top & bottom duly internally secured with wire mesh, with suitable internal wiring with copper cable of suitable size etc with double stud hinged door, front openable with locking arrangement including interlocking with switch gears and to withstand short circuit fault level of not less than 100KA and degree of protection shall be IP 54. The panel shall be fixed with angle iron frame made of angles of size 75x75x8mm at Corners and ISMC of suitable size for base, embedded 600 mm below ground level in PCC 1:2:4, Type B–1 using 20mm grade stone aggregate, 600 mm above ground level complete including connecting up with existing incoming and outgoing cables, dismantling old panel board etc. and comprising the following:-
1
-
-
... More
[a] ACB, 1250 Amps, FP, 50 KA, 415 Volts, 3 Phase, AC, 50 Hz, Manual draw out type with microprocessor release – 02 No. [Incoming]
[b] Bus coupler breaker (ACB) panel 4 Pole, 415 Volts manual drawout type with microprocessor release of capacity 1250 Amps - 01 No
[c] Outgoing MCCB 4 Pole, 400 Amps 36 KA, 415 Volts, 50 Hz - 04 Nos
[d] Outgoing MCCB 4 Pole, 250 Amps 16 KA, 415 Volts, 50 Hz - 06 Nos
[e] Outgoing MCCB 4 Pole, 160 Amps 16 KA, 415 Volts, 50 Hz - 04 Nos
[f] Digital intelligent Panel meter to measure voltage, current, frequency, power factor, KWH, etc with all connected CTs - 02 Nos
[g] Aluminium Bus bar for 3 phase & neutral supply
[h] Colour Coded LED Phase Indicating Lamps for each Phase – 17 Sets.
-
-
-
... More
Supplying, Installing, Commissioning and Testing of CPRI Prototype tested, Factory made, Platform Mounted, Dust and Vermin proof LT Cubical Panel Board, Compartmentalised, Outdoor type, fabricated with 3.15mm thick CRCA Sheet and shall be given pre-treatment for degreasing, phosphatising etc. in seven tank process and shall be powder coated with RAL7035 coat with matt finish after due preparation of surfaces. The panel shall consists of 800 Amps rating TPN bus bars of high conductivity Aluminium and shall be provided with colour coded heat shrinkable sleeves mounted on porcelain/ SMC insulator supports, suitable double Compression Copper Cable Glands and panel shall be provided with separate compartments for each switch, with gland plates, lifting hooks, shutter type ventilating louver at both top & bottom duly internally secured with wire mesh, with suitable internal wiring with copper cable of suitable size etc with double stud hinged door, front openable with locking arrangement including interlocking with switch gears and to withstand short circuit fault level of not less than 100KA and degree of protection shall be IP 54. The panel shall be fixed with angle iron frame made of angles of size 75x75x8mm at Corners and ISMC of suitable size for base, embedded 600 mm below ground level in PCC 1:2:4, Type B–1 using 20mm grade stone aggregate, 600 mm above ground level complete including connecting up with existing incoming and outgoing cables, dismantling old panel board etc. and comprising the following:-
2
-
-
... More
[a] ACB, 1250 Amps, Four Pole, 35 KA, 415 Volts, thermal magnetic release manual drawout type – 01 No. [Incoming]
[b] Outgoing MCCB 4 Pole, 400 Amps 25 KA, 415 Volts, 50 Hz, fixede type - 01 No
[c] Outgoing MCCB 4 Pole, 250 Amps 25 KA, 415 Volts, 50 Hz, fixede type - 03 Nos
[d] Outgoing MCCB 4 Pole, 160 Amps 25 KA, 415 Volts, 50 Hz, fixede type - 02 Nos
[e] Digital intelligent Panel meter to measure voltage, current, frequency, power factor, KWH, etc with all connected CTs - 01 Nos
[f] Aluminium Bus bar for 3 phase & neutral supply
[g] Colour Coded LED Phase Indicating Lamps for each Phase – 01 Sets.
-
-
-
... More
Earthing complete with Galvanised Steel Earth Plate Electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of Plate not less than 1.50 m below normal ground level connected to galvanised earth strip 32x6mm [Earth Lead] and GI pipe 40 mm dia medium Grade for earthing lead protection to the extent of maximum 7.5m, earth plate electrode surrounded by 150mm thick packed layers of charcoal and common salt filled in alternate layers, connected to the plate by means of GI bolts & nuts complete all as per Electrical plate No. 3 of SSR Part – I, connected to earthing test point including testing on completion including PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm angle iron, MS funnel with 20 mm bore medium grade GI Watering pipe, wire mesh, earth work excavation, returning filling, removal of surplus soil etc. complete all as specified and as directed.
30
-
-
... More
S & F Cable Jointing Kit for 11 KV [Earthed] Grade cable for straight through joint heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 Sqmm, complete all as specified and as directed.
4
-
-
... More
S & F Cable Jointing Kit for 11 KV [Earthed] Grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 Sqmm, complete all as specified and as directed.
6
-
-
... More
S & F Cable Jointing Kit for 11 KV [Earthed] Grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 to 300 Sqmm, complete all as specified and as directed.
2
-
-
... More
S & F Cable Jointing Kit for 11 KV [Earthed] Grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 Sqmm, complete all as specified and as directed.
2
-
-
... More
S & F Cable Jointing Kit for 11 KV [Earthed] Grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 to 300 Sqmm, complete all as specified and as directed.
2
-
-
... More
Supplying, laying and testing HT UG cable [earthed], XLPE insulated, screened insulated, steel strip armoured and pressure extruded PVC bedded, 11000 Volts grade [heavy duty] with aluminium conductor of size 3 Core 185 Sqmm laid in trenches, fixed to walls or passing through pipes and connecting up including taking out old cable complete all as specified and as directed.
150
-
-
... More
Supplying, laying and testing LT UG cable, XLPE insulated, screened insulated, steel strip armoured and pressure extruded PVC bedded, 1100 Volts grade [heavy duty] with aluminium conductor of size 3.5 Core 300 Sqmm laid in trenches, fixed to walls or passing through pipes and connecting up including taking out old cable complete all as specified and as directed.
300
-
-
... More
Supplying, laying and testing LT UG cable, XLPE insulated, screened insulated, steel strip armoured and pressure extruded PVC bedded, 1100 Volts grade [heavy duty] with aluminium conductor of size 3.5 Core 240 Sqmm laid in trenches, fixed to walls or passing through pipes and connecting up including taking out old cable complete all as specified and as directed.
260
-
-
... More
Supplying, laying and testing LT UG cable, XLPE insulated, screened insulated, steel strip armoured and pressure extruded PVC bedded, 1100 Volts grade [heavy duty] with aluminium conductor of size 3.5 Core 185 Sqmm laid in trenches, fixed to walls or passing through pipes and connecting up including taking out old cable complete all as specified and as directed.
1330
-
-
... More
Supplying, laying and testing LT UG cable, XLPE insulated, screened insulated, steel strip armoured and pressure extruded PVC bedded, 1100 Volts grade [heavy duty] with aluminium conductor of size 3.5 Core 150 Sqmm laid in trenches, fixed to walls or passing through pipes and connecting up including taking out old cable complete all as specified and as directed.
200
-
-
... More
Supplying, laying and testing LT UG cable, XLPE insulated, screened insulated, steel strip armoured and pressure extruded PVC bedded, 1100 Volts grade [heavy duty] with aluminium conductor of size 3.5 Core 120 Sqmm laid in trenches, fixed to walls or passing through pipes and connecting up including taking out old cable complete all as specified and as directed.
150
-
-
... More
Supplying, laying and testing LT UG cable, XLPE insulated, screened insulated, steel strip armoured and pressure extruded PVC bedded, 1100 Volts grade [heavy duty] with aluminium conductor of size 3.5 Core 95 Sqmm laid in trenches, fixed to walls or passing through pipes and connecting up including taking out old cable complete all as specified and as directed.
320
-
-
... More
Supplying, laying and testing LT UG cable, XLPE insulated, screened insulated, steel strip armoured and pressure extruded PVC bedded, 1100 Volts grade [heavy duty] with aluminium conductor of size 3.5 Core 50 Sqmm laid in trenches, fixed to walls or passing through pipes and connecting up including taking out old cable complete all as specified and as directed.
90
-
-
... More
Supplying, laying and testing LT UG cable, XLPE insulated, screened insulated, steel strip armoured and pressure extruded PVC bedded, 1100 Volts grade [heavy duty] with aluminium conductor of size 4 Core 25 Sqmm laid in trenches, fixed to walls or passing through pipes and connecting up including taking out old cable complete all as specified and as directed.
300
-
-
... More
Excavation in trenches not exceeding 1.5m wide and not exceeding 10 Sq.m on plan area and not exceeding 1.5m deep in soft/ loose soil complete all as specified and as directed.
648
-
-
... More
Removing excavated material /soil to a distance not exceeding 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed
318
-
-
... More
M&L for Sand filling in trenches using dry river sand as cushioning to under ground cable including spreading, levelling and consolidation complete all as specified and directed.
[Note: Punned thickness of sand shall only be measured.]
260
-
-
... More
M & L for laying sub class 'B' bricks of old size 230mm x 115mm x 75mm for cable protection laid across alignment of cable in trenches complete all as specified and directed.
20870
-
-
... More
M & L for cutting existing road / hard standing for laying of UG cables not exc 300mm in width and cutting of depth not exc 600mm including refilling after laying of cable and making good the disturbed road surfaces with 100mm thick PCC 1:2:4, type B-1 using 20mm graded stone aggregate and removing of surplus soil not exc 50m complete all as specified and directed
70
-
-
... More
M & L for laying 100mm dia GI pipe light grade laid for cable protection at road crossings or fixed on walls / poles secured with clamps complete all as directed
45
-
-
... More
M & L for laying 80mm dia GI pipe light grade laid for cable protection at road crossings or fixed on walls / poles secured with clamps complete all as directed
35
-
-
... More
M & L for laying 50mm dia GI pipe light grade laid for cable protection at road crossings or fixed on walls / poles secured with clamps complete all as directed
25
-
-
... More
Supply and laying unreinforced precast concrete cable covers of class HPV, type-1, flat of size 300x180x40mm laid in trenches as in cable protection complete all as directed
750
-
-
... More
M & L for 100mm thick, PCC 1:2:4, Type B-1, using 20mm graded stone aggregate as in Pavement / hard standing finished by brooming laid in alternate bays complete all as specified and as directed.
6
-
-
... More
Returning filling in, including spreading, levelling,watering and well ramming in layers not exc 25cm thickness as in soil complete all as specified and directed.
330
-
-
... More
Taking down carefully existing interlocking paver blocks of 60mm thick and relaying the same at the location as directed by the Engineer-in-Charge over 50mm thick sand cushioning ocomplete all as specified and as directed.
6
-
-
... More
M & L for boring holes horizontally under road, manually in soft / loose soil without cutting / disturbing the existing road surface suitable for inserting GI pipe at depth of 0.60m to 1.0m from road surface for passing of UG cable including getting out and disposal of soil to a distance not exc 50m complete all as directed by the Engineer-in-Charge. [Note: GI pipe shall be measured and paid seperately]
35
-
-
... More
M & L for dismantling and removing existing HT [11 KV] four pole / two pole structure including all accessories, ACSR conductor, insulators, GOD and other connected items complete alla s directed
2
-
-
... More
S & F Cable Jointing Kit for LT UG cable for straight through joint heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 240 Sqmm, complete all as specified and as directed.
10
-
-
... More
S & F Cable Jointing Kit for LT UG cable for straight through joint heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 150 to 185 Sqmm, complete all as specified and as directed.
6
-
-
... More
S & F Cable Jointing Kit for LT UG cable for straight through joint heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 90 to 120 Sqmm, complete all as specified and as directed.
10
-
-
... More
S & F Cable Jointing Kit for LT UG cable for straight through joint heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 25 to 70 Sqmm, complete all as specified and as directed.
3
-
-
... More
Supplying, laying and testing LT UG cable, XLPE insulated, screened insulated, steel strip armoured and pressure extruded PVC bedded, 1100 Volts grade [heavy duty] with aluminium conductor of size 3.5 Core 400 Sqmm laid in trenches, fixed to walls or passing through pipes and connecting up including taking out old cable complete all as specified and as directed.
600
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%