Military Engineer Services Tender

To know what Andhra Pradesh government has posted about any AP etender, Bidassist helps us to get a one-stop platform where a registered bidder can have access to the details on each and every eprocurement tender. There is no need to provide the details on the AP E-procurement website i.e. https://www.apeprocurement.gov.in as BidAssist helps us find the specific etender we're looking for. BidAassist has collated each and every Eproc Andhra Pradesh Tender on its website.

Military Engineer Services - MES Tender

Works
Eprocure
Opening Date11 Nov 2024
Closing Soon2 Dec 2024
Tender Amount₹ 13,72,000 
Notes
Download

Costs

Summary

Maintenance To Air-conditioning,water Coolers And Allied E/m Services At Aob Rambilli.

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
All as item No 1.00 here-in -before but for Deep Freezer.

1

-

-

... More
Finding the leakage in refrigerant system by nitrogen pressure test etc and rectifying the leakage by brazing,welding including installation and complete testing of the Water cooler of capacity 40/40 ltr, 120/80 ltr & 120/150 ltr all as specified and directed. Note: (i)The necessary nitrogen required for leak test deemed to be included in the quoted rates. (ii) The refrigerant gas reqd will be paid under relevant item of BOQ.

4

-

-

... More
All as item No 5.00 here-in -before but for Split type AC 1.5 ton/2 ton capacity

1

-

-

... More
All as item No 5.00 here-in -before but for Refrigerator 165/310 ltr capacity

2

-

-

... More
All as item No 5.00 here-in -before but for Deep Freezer

1

-

-

... More
All as item No 5.00 here-in -before but for package type Ac plant of 4.8 TR of Hitachi make of model RAS-6.0HNBRQ

3

-

-

... More
All as item No 6.00 here-in -before but for package type Ac plant of 5.5TR

8

-

-

... More
M&L for Charging of refrigerant gas (R-22/134A/ HCFC/R407/R404 etc ) to existing Window AC/ Split AC /Deep Freezer/Refrigerator/Package type AC of any description, any make & in any position to makeup required pressure complete all as directed.

120

-

-

... More
M&L for replacement of the following parts/items of split/window type AC 1.5 ton / 2.0 ton capacity,package AC 4.8 to 5.5 TR, water cooler 80 ltr / 150 ltr capacity, refrigerator 165 ltr / 310 ltr capacity, and desert coolers etc complete all as specified and as directed.

-

-

-

... More
Starting capacitor of 80/100 mfd capacity Make: Asian/Keltern/Unistar/EPSCO/Keal

10

-

-

... More
Starting capacitor of 100/120 mfd capacity

6

-

-

... More
Running capacitor of 4.5 MFD capacity

1

-

-

... More
Running capacitor of 50 MFD capacity

1

-

-

... More
Starting capacitor of capacity 10 MFD/20MFD

1

-

-

... More
Running capacitor of 4 MFD.

1

-

-

... More
Thermostat switch for water cooler Make : Renutral/Shriram/Indfoss

4

-

-

... More
Thermostat switch for AC 1.5 ton/2.0 ton capacity, Split/window type Make : Renutral/Shriram/Indfoss

1

-

-

... More
Thermostat switch for Refrigerator Make : Renutral/Shriram/Indfoss

4

-

-

... More
Wiring kit for water cooler

3

-

-

... More
wiring kit for window type / split type AC

1

-

-

... More
PVC air filter for split AC

2

-

-

... More
PCB for Cooling Only 2 TR Split Ac as per existing make

1

-

-

... More
Brass service valve for split type A/C of size 5/8” or 3/8'' or 11/8" dia service valve all as approved (Make : CAM)

1

-

-

... More
Refrigerator Freezer coil & freezer coil type/roll bound type complete suitable for 165 ltr. to 230 ltr. capacity

2

-

-

... More
Brass Nipple 15 mm dia for inlet and out let connection of water cooler

10

-

-

... More
Drain Pipe PVC flexible 1¼” dia with one end circle clip

1

-

-

... More
CP brass Push cock, 15 mm. Dia.

4

-

-

... More
M&L Chemial servicing of 5.5 TR condenser unit by descaling agent diluted HCL for outdoor units (condensers) and filter cleaning for indoor ductable/split units of the same complete all as specified and directed by Engr-in-Charge.

8

-

-

... More
All as item No 31.00 here-in -before but for 4.8 TR Condenser unit

3

-

-

... More
M&L for replacement of 3 core flexible copper cable of size 40/0.0076 with thimble etc complete all as specified and as directed.

30

-

-

... More
S&F in replacement plug top 3, pin 5 Amp complete all as specified

10

-

-

... More
S&F in replacemen plug top 3, pin 15 Amp complete all as specified

10

-

-

... More
M&L for replacement of condenser unit of 2 TR split type AC unit including necessary brazing, welding complete all as specified and directed by Engr-in-Charge .Note:- The Compressor required shall be paid under relevant item of Schedule 'A'.

1

-

-

... More
M&L for replacement of indoor evaporator coil unit of 2 TR split type AC unit incl necessary brazing, welding complete all as specified and directed by Engr-in-Charge.

1

-

-

... More
M&L for replacement of burnt compressor of water cooler 80-150 ltr per hours cooling capacity. including dismantling the unserviceable burnt after disconnecting suction/discharge side copper tube bolts rubber pads and washers connecting copper tubing by welding blazing nut flaring and repairing of gas leakage if any completeall as specified and as directed.

4

-

-

... More
All as item No 38.00 here-in -before but for Split type AC 2.0/1.5 ton capacity

1

-

-

... More
All as item No 38.00 here-in -before but for refrigerator 165 ltr capacity

4

-

-

... More
All as item No 38.00 here-in -before but for refrigerator 310 ltr capacity

3

-

-

... More
All as item No 38.00 here-in -before but for deep Freezer 200 to 315 ltr capacity

1

-

-

... More
M&L for replacement of blower fan motor of existing size and capacity in cooling unit of split type AC capacity 2.0/1.5 TR complete all as specified and as directed.

1

-

-

... More
M&L for replacement of Condensor fan motor of existing size and capacity in outdoor unit of split type AC capacity 2.0/1.5 TR complete all as specified and as directed .

1

-

-

... More
M&L for replacement of copper tube of size 1/4" or 3/5'' dia for cooling unit to condensing unit for split ACs complete all as specified and as directed.

5

-

-

... More
All as item No 45.00 here-in -before but of size 1/2'' or 5/8" dia

5

-

-

... More
M&L for replacement of insulation for copper tube of size 1/4" or 1/2" or 3/8" or 5/8" dia for cooling unit to condensing unit for split Acs as per existing complete all as specified and as directed.

5

-

-

... More
M&L for writing/making SL, SM, MES Nos with black/white paint with stencil on indoor and outdoor unit of split Acs window type Acs water cooler desert coolers, stabilizers of any make and any capacity all as specified and as directed.

30

-

-

... More
M&L for replacement of PCB ,sensor display unit of 1.5/2 TR inverter type split type AC unit incl necessary joining, welding with necessary bolt & nuts complete all as specified and directed by Engr-in-Charge.

1

-

-

... More
M&L for replacement in repairs of oscillation motor of 2 TR split type AC unit incl necessary joining, welding with necessary bolt & nuts complete all as specified and directed by Engr-in-Charge.

1

-

-

... More
M&L for replacement of metal clad socket outlet 3 pin of capacity 20 Amps 240V complete all as specified and as directed.

10

-

-

... More
M&L for replacement of metal clad plug top of capacity 20 Amps, 240V complete all as specified and as directed.

10

-

-

... More
M&L for replacement of float valve 15mm bore of brass with L type nipple & polythene float valve complete all as specified and as directed.

8

-

-

... More
M&L for replacement CRCA outer housing/body parts of outdoor unit of 2 TR split type AC unit including necessary joining, welding with bolt & nuts complete all as specified and directed by Engr-in-Charge.

1

-

-

... More
M&L for replacement outer housing body parts of indoor unit of 2 TR split type AC unit incl necessary joining, welding with necessary bolt & nuts complete all as specified and directed by Engr-in-Charge.

1

-

-

... More
Servicing/repairing of 11 TR air cooled ductable split air conditioner unit of capacity 5.5 TR with scroll compressor from its existing position and refixing of the same after repairing including/cleaning filter removing internal dust by using air blower and vacuum cleaner, oiling, greasing wherever required including checking / testing after completion all as specified and as directed. Note : (i) Unserviceable/defective items which is required to be replaced shall be measured and paid separately.

4

-

-

... More
All as item No 56.00 here-in -before but of 4.8 TR Condenser unit

3

-

-

... More
M&L for PCB of outdoor unit suitable for 4.8TR capacity for existing AC make Hitachi model No RAS-6.0HNBRQ complete all as specified and as directed.

2

-

-

... More
M&L for suitable PCB for 5.5TR capacity existing AC make Bluestar complete all as specified and as directed.

2

-

-

... More
M&L for Volume control dampers/duct dampers with operating handlesuitable for 09 to 11 TR capacity for supply air duct branches complete all as specified and as directed.

2

-

-

... More
M&L for canvas connection for ductable units complete all as specified and as directed.

2

-

-

... More
Supply , assembly and erection of GI sheet with TDF flange rectangular/square duct made out of 'L' shaped hollow profile, duly factory boxed, including all accessories such as Corner, Cleat, Carriage bolt, Gasket and appropriate sealant on longitudinal joints etc of size 24 Gauge complete all as specified and as directed.

20

-

-

... More
All as per item no.62.00 here-in before but of size 22 gauge

20

-

-

... More
M&L in replacement of MCCB 4pole 125 Amps 25 KA complete all as specified and as directed.

3

-

-

... More
S&F in repairs to Voltage stabilizer of 2KVA to 5KVA of any make and model complete all as specified and as directed.

15

-

-

... More
M&L for replacement of MNX-25/ 32 Amps Contactor including necessary screws, nuts and bolts complete all as specified and as directed.

2

-

-

... More
M&L for Contactor suitable to Split Acs of capacity 2TR complete all as specified and as directed.

2

-

-

... More
M&L for replacement of burnt scroll compressor including dismantling the unserviceable burnt after disconnecting suction/discharge side copper tube bolts rubber pads and washers connecting copper tubing by welding blazing nut flaring and repairing of gas leakage if any and completesuitable for 5.5 TR ductable split AC all as specified and as directed.

2

-

-

... More
All as per item no.68.00 here-in before but off 4.8 TR rotary compressor.

2

-

-

... More
M&L for rewinding of blower fan motor of existing size and capacity in cooling unit of ductable split type AC capacity 5.5 TR complete all as specified and as directed.

4

-

-

... More
All as per item no.70.00 here-in before but of 2.0 TR split type unit

1

-

-

... More
M&L for rewinding of Condensor fan motor of existing size and capacity in outdoor unit of AC capacity 5.5 TR complete all as specified and as directed.

2

-

-

... More
All as per item No.72.00 here-in before but 4.8 TR capacity

2

-

-

... More
M&L for HDPE pipes for drain out the drain points 25mm dia (each unit drain out) complete all as specified and as directed.

10

-

-

... More
M&L for power and control cabling between the indoor unit and out door unit of size 4 core x 1.5 sqmm copper wire complete all as specified and as directed.

10

-

-

... More
M&L for power and control cabling between the indoor unit and out door unit of size 4 core x 2.5 sqmm copper wire complete all as specified and as directed.

10

-

-

... More
M &L for duct accoustic insulation 25 mm thick with resin bonded fibre glass wool rigid board covered with tissue paper with 26 gauge GI perforated shee complete all as specified and as directed.

10

-

-

... More
M &L for duct thermal insulation 50 mm thick with aluminium foil faced fiber glass material of density 24 kg/cum, with factory laminated aluminium vapour barrier 26 guage thickness including (a) M&L for cleaning the duct surface (to be insulated ) by scrapping carefully with wire brush etc. to make the surface completely free of millscale, dirt, dust, grease and other foreign materials, taking special care so that all duct joints are sealed against any leakage. (b) M&L for applying rubber based adhesive CPRX compound. (c) M&L for sealing of all longitudinal joints and circular overlaps with and including Aluminium foil tape 50 mm wide, to make the insulation leakproof. (d) M & L for securing the insulation with and including mechanically fastened nylon/ steel straps of size 12 mm/50 mm at maximum intervals of 1.2 mtr.

10

-

-

... More
M&L for powder coated extruded aluminium supply air/4way diffuser with standard flanges complete all as specified and as directed.

1.6

-

-

... More
cutting of tree branches,cleaning of bushes.small plants surrounded the E/M installations including removing debris to a distance not exc 50m complete all as specified and as directed.

2060

-

-

... More
Material and labour for submain wiring alongwith earth continuity conductor with PVC insulated FRLS multistrand copper conductor cable (Phase - Red, Neutral - Black, Earth - Green) of nominal size 2x4 sq mm + 1x4 sq mm (earth) drawing through and including PVC casing capping of suitable size and its accessories complete all as specified and directed. Note.(a) Two runs of single cable with one run of earth continuity cable ncluding PVC casing capping and its accessories shall be measured and paid as one unit. (b) surface shall be make good as existing.

80

-

-

... More
Material and labour for submain wiring alongwith earth continuity conductor with PVC insulated FRLS multistrand copper conductor cable (Phase - Red, Neutral - Black, Earth - Green) of nominal size 2x6 sq mm + 1x6 sq mm (earth) drawing through and including PVC casing capping of suitable size and its accessories complete all as specified and directed. Note.(a) Two runs of single cable with one run of earth continuity cable ncluding PVC casing capping and its accessories shall be measured and paid as one unit. (b) surface shall be make good as existing.

100

-

-

... More
S&F 230 V AC,50 Hz,25 Amp with cyclic timer 3-999 minute programmable interval between two AC (Programmable alternate operation of AC-01 AND AC-02) AC ON indication for AC-01 and AC-02 power on indication single phase and two input terminal etc complete all as specified and as directed.

3

-

-

... More
S&F in replacement of old rusted AC mounting bracket with replacing 24 inch heavy duty wall mounted bracket load bearing capacity upto 50 Kg complete all as specified and as directed.

4

-

-

... More
Supply and fixing in replacement of 415V 10KA 'C' curve miniature circuit breaker (MCB) of TP 63 Ams and current carrying capacity in the DB complete with connection testing and commissioning.complete all as specified and as directed.

5

-

-

... More
Supply and fixing in replacement of 415V 10KA 'C' curve miniature circuit breaker (MCB) of TPN 100 Ams and current carrying capacity in the DB complete with connection testing and commissioning.complete all as specified and as directed.

5

-

-

... More
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) SP5-32 Ams and current carrying capacity in the MCB DB complete with connection testing and commissioning.complete all as specified and as directed.

10

-

-

... More
Supply and fixing inreplacement of 25/32/40 Amps RCCB A-Type (DP-2M) 240 Volt, 50Hz,10 KA breaking capacity 100mA a.complete all as specified and as directed.

5

-

-

... More
Attending complaints related to air conditioning system package type/cassete type from 4.8 11TR including detecting of internal faults any type.complete all as specified and as directed. Note:(a) contractor shall attend the complaints on requirement basis from 0930hr to 1730hr on working days including saturday/sunday/holidays (if required. (b) Contractor shall deployed one highly skilled refrigeration mechanic and helper unskilled category for attending the complaint. (c) quoted rate shall deemed to include cost of one highly skilled refrigeration mechanic and helper unskilled category.

5

-

-

... More
Total Amount in Figures

-

-

-

... More
Quoted Amount in Words

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.