Military Engineer Services Tender
To know what Andhra Pradesh government has posted about any AP etender, Bidassist helps us to get a one-stop platform where a registered bidder can have access to the details on each and every eprocurement tender. There is no need to provide the details on the AP E-procurement website i.e. https://www.apeprocurement.gov.in as BidAssist helps us find the specific etender we're looking for. BidAassist has collated each and every Eproc Andhra Pradesh Tender on its website.
Military Engineer Services - MES Tender
Security and Emergency Services
Electrical and Electronics
Electrical Works
Eprocure
Opening Date30 Oct 2023
Closing Date20 Nov 2023
Tender Amount₹ 40,00,000
Costs
EMD
₹ 80,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_MES_625785_1Bid Award Id
ViewTender No
C/8243/23-24/E8 / Token 80 of 2023-24Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
M & L for Sub main wiring with 2 runs of Single core 4 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLS (ISI marked) copper cable drawn through and including surface PVC conduit of suitable size with all conduit accesories and fittings along with 1 run of single core 4 sqmm PVC insulated multi stranded FRLS (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed.
(Note :- Two runs of 4 sqmm and one runs of 4 sqmm cable as earth wire and one run of conduit shall be measured as one length)
30
-
-
M & L for Sub main wiring with 2 runs of Single core 6 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLS (ISI marked) copper cable drawn through and including surface PVC conduit of suitable size with all conduit accesories and fittings along with 1 run of single core 6 sqmm PVC insulated multi stranded FRLS (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed.
(Note :- Two runs of 6 sqmm and one runs of 6 sqmm cable as earth wire and one run of conduit shall be measured as one length)
30
-
-
M & L for Sub main wiring with 4 runs of Single core 6 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLS (ISI marked) copper cable drawn through and including surface PVC conduit of suitable size with all conduit accesories and fittings along with one run of single core 6 sqmm PVC insulated multi stranded FRLS (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed.
(Note :- Four runs of 6 sqmm and one runs of 6 sqmm cable as earth wire and one run of conduit shall be measured as one length)
35
-
-
M & L for Sub main wiring with 2 runs of Single core 10 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLS (ISI marked) copper cable drawn through and including surface / ceiling PVC conduit of suitable size with all conduit accesories and fittings along with 1 run of single core 10 sqmm PVC insulated multi stranded FRLS (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed.
(Note :- Two runs of 10 sqmm and one runs of 10 sqmm cable as earth wire and one run of conduit shall be measured as one length)
50
-
-
M & L for Sub main wiring with 4 runs of Single core 10 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLS (ISI marked) copper cable drawn through and including surface PVC conduit of suitable size with all conduit accesories and fittings along with one run of single core 10 sqmm PVC insulated multi stranded FRLS (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed.
(Note :- Four runs of 10 sqmm and one runs of 10 sqmm cable as earth wire and one run of conduit shall be measured as one length)
40
-
-
S & F in repair Single phase sheet metal enclosure with socket plug top and MCBs having single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of capacity 20Amp 240V, B-curve complete all as specified and as directed. (Make: Havell's Cat No. DHDPUSN020 or equivelant of make as per List of Manufacturer's)
100
-
-
S & F in repair Single phase sheet metal enclosure with socket plug top and MCBs having Triple pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of capacity 32 Amp 415V, C-curve complete all as specified and as directed. (Make: Havell's Cat No. DHDPUTN030 or equivelant of make as per List of Manufacturer's)
5
-
-
S & F Vertical TPN DB double door for provision for four pole MCCB upto 160 A incommer 4 way 12 outgoing with IP 43 protectioncomplete all as specified and as directed. (Make : Legrand cat part No. 5077 45 or equivelant of make as per List of manufacturer's)
10
-
-
S & F Vertical TPN DB double door for provision for four pole MCCB upto 160 A incommer 6 way 18 outgoing with IP 43 protectioncomplete all as specified and as directed. (Make : Legrand cat part No. 5077 46 or equivelant of make as per List of manufacturer's)
5
-
-
S & F Vertical TPN DB double door for provision for four pole MCCB upto 160 A incommer 8 way 12 outgoing with IP 43 protectioncomplete all as specified and as directed. (Make : Legrand cat part No. 5077 47 or equivelant of make as per List of manufacturer's)
5
-
-
S & F MCCB 415 Volt, 25 KA, 4 Pole, 63 Amps Capacity complete all as specified and as directed. (Make: Legrand Cat Part No. 4200 53 or equivelant of make as per List of Manufacturer's)
5
-
-
S & F MCCB 415 Volt, 25 KA, 4 Pole, 100 Amps Capacity complete all as specified and as directed. (Make: Legrand Cat Part No. 4200 55 or equivelant of make as per List of Manufacturer's)
5
-
-
S & F MCCB 415 Volt, 25 KA, 4 Pole, 125 Amps Capacity complete all as specified and as directed. (Make: Legrand Cat Part No. 4200 56 or equivelant of make as per List of Manufacturer's)
5
-
-
S & F MCCB 415 Volt, 25 KA, 4 Pole, 160 Amps Capacity complete all as specified and as directed. (Make: Legrand Cat Part No. 4200 57 or equivelant of make as per List of Manufacturer's)
5
-
-
S & F in repair MCCB 415 Volt, 25 KA, 4 Pole, 63 Amps Capacity complete all as specified and as directed. (Make: Legrand Cat Part No. 4200 53 or equivelant of make as per List of Manufacturer's)
15
-
-
S & F in repair MCCB 415 Volt, 25 KA, 4 Pole, 100 Amps Capacity complete all as specified and as directed. (Make: Legrand Cat Part No. 4200 55 or equivelant of make as per List of Manufacturer's)
10
-
-
S & F in repair MCCB 415 Volt, 25 KA, 4 Pole, 125 Amps Capacity complete all as specified and as directed. (Make: Legrand Cat Part No. 4200 56 or equivelant of make as per List of Manufacturer's)
15
-
-
S & F in repair MCCB 415 Volt, 25 KA, 4 Pole, 160 Amps Capacity complete all as specified and as directed. (Make: Legrand Cat Part No. 4200 57 or equivelant of make as per List of Manufacturer's)
10
-
-
S & F in repair MCCB 415 Volt, 25 KA, 4 Pole, 200 Amps Capacity complete all as specified and as directed. (Make: Legrand Cat Part No. 4202 18 or equivelant of make as per List of Manufacturer's)
3
-
-
S & F in repair MCCB 415 Volt, 25 KA, 4 Pole, 250 Amps Capacity complete all as specified and as directed. (Make: Legrand Cat Part No. 4202 19 or equivelant of make as per List of Manufacturer's)
3
-
-
S & F in repair Spreaders, 4 pole suitable upto 400 Amps complete all as specified and as directed. (Make: Legrand Cat No. 6250 18 or equivelant as per List of Manufacturer)
10
-
-
S & F in repair Spreaders, 3 pole suitable upto 250 Amps complete all as specified and as directed. (Make: Legrand Cat No. 6250 14 or equivelant as per List of Manufacturer)
20
-
-
S & F in repairs MCCB enclosure IP 43 with solid neutral link suitable for 4 pole MCCBs complete and making good disturbed surfaces complete all as specified and as directed. (Make: Legrand Cat No. 5078 06 or equivelant as per List of Manufacturer)
15
-
-
Supply and laying cable XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 Sqmm 4 core, fixing along the poles or passing through pipes or laid under floor of through walls etc jointing and testing including taking out/down existing cable complete all as specified and directed. (Note: Excavation and earth work will be measured and paid seperately)
340
-
-
Supply and laying cable XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 10 Sqmm 2 core, fixing along the poles or passing through pipes or laid under floor of through walls etc jointing and testing including taking out/down existing cable complete all as specified and directed. (Note: Excavation and earth work will be measured and paid seperately)
250
-
-
Excavation in trenches, not exceeding 1.5 M wide and not exceeding 1.5 M depth for foundation, trenches for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sq m on plan and n exc 1.5m in depth and getting out in soft/loose soil complete all as specified and directed.
87
-
-
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm as in soft/loose soil complete all as specified and directed.
51
-
-
Removing excavated material not exc. 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed.
36
-
-
Supply and laying well burnt bricks, fly ash bricks laid breath wise across the length of cable in trenches for protection of UG cables complete all as specified and directed.
2100
-
-
M & L for Sand cushioning with clean dry sand in trenches for protection of under ground cables (below, above and around the cable laid in trenches) complete all as specified and directed.
(Note: Thickness after punning down shall be measured for payment)
33
-
-
S & F in repairs IP 66 junction box made of impact resistance polycarbonate & heat resistant materials of size 200x160x98mm mm, dust proof, water tight, light weight, acid resistant, corrotion proof insulated and shock proof, fire retardant, self extinguishing, helogen & silica free non toxic material, UV resistant with internally embedded gasket and fitted with required terminals alongwith type test certificate and veryfied by glow-wire test in accordance with IEC60695-2-11 complete all as specified and directed directed. (Make : HENSEL, Cat No : KF9255 or equivalent model of make as per list of manufacturer)
60
-
-
S & F in repairs LED outdoor Security light fittings, Min IP 65 rated, aluminium die cast housing with powder coating, pole mounted, 36 Watt, Lumen ≥ 3600, Luminous afficacy ≥ 100 Lum/Watt, CCT:WW/NW/CW, CRI 70 Ra, 4KV surge Protection with open and short circuit protections as per IS: 10322 with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including lamp complete all as specified and directed. (Make: Jaquar Cat No. LPCRSRT36WXC or equivelant of make as per list of manufacturer)
50
-
-
S & F in repairs LED outdoor Flood light fittings, Min IP 65 rated, High pressure aluminium die cast housing and toughened glass cover, 70 Watt, Lumen ≥ 7000, Luminous afficacy ≥ 100 Lum/Watt, CCT:WW/NW/CW, CRI 70 Ra, 4KV surge Protection with open and short circuit protections as per IS: 10322 with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including lamp complete all as specified and directed. (Make: Jaquar Cat No. LFLDSLM070XC or equivelant of make as per list of manufacturer)
15
-
-
S & F in repairs LED outdoor Flood light fittings, Min IP 66 rated, High pressure aluminium die cast housing and toughened glass cover, 100 Watt, Lumen ≥ 10000, Luminous afficacy ≥ 110 Lum/Watt, CCT:WW/NW/CW, CRI 70 Ra, 4KV surge Protection with external SPD of 10 KV, with open and short circuit protections with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including lamp complete all as specified and directed. (Make: Jaquar Cat No. LFLDSLM100XC or equivelant of make as per list of manufacturer)
5
-
-
S & F in repairs LED light fittings, Ceiling mounted, panel type, white powder coated CRCA body, PC lens, Approx dimensions 1'x4', 33 Watt, Lumen ≥ 3300, Luminous afficacy ≥ 100 Lum/Watt, CCT:WW/NW/CW, CRI 80 Ra,min IP 40 rated, THD ≤ 20% & PF ≥0.9, over voltage protection withstand upto 360 (for 10 Minutes), 4KV surge Protection with open and short circuit protections as per IS: 10322 with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including lamp complete all as specified and directed. (Make: Jaquar Cat No. LULU4SL033XC or equivelant of make as per list of manufacturer)
40
-
-
S & F in repairs LED light fittings, 1'x4', 40 Watt, 230 Volts AC with high performance, commercial grade solution industrial application with impact and corrosion resistant, IP65 rating complete with driver and lamp and with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including lamp complete all as specified and directed. (Make: Jaquar Cat No. LPRD01040XW or equivelant of make as per list of manufacturer)
20
-
-
S & F in repair 25 Watt, 230 Volts AC Post Top Lantern, outdoor type with decorative post top for 360 Degree indirect light, IP 65 protection with impact and corrosion reisitant comp[lete with driver and lamp, fixing accessories and connecting up with suitable copper conductor complete all as specified and directed. (Make: Havell's Cat No. CORALPT25WLED830SSYMTOPC or equivelant of make as per list of manufacturer)
18
-
-
S & F in repairs 10 Watt, 230 Volts AC, LED Bollard light fittings with soft 360 light distribution, Min IP 65 rated, outdoor type with decorative light with impact and corrosion resistant with driver and lamp and with all accessories and connecting up with twin core twisted copper conductor cable of suitable size including lamp and making good disturbed surfaces complete all as specified and directed. (Make: Jaquar Cat No. LBLDC0N010XW or equivelant of make as per list of manufacturer)
25
-
-
S & F in repairs 10 Watt, 230 Volts AC, LED Bollard light fittings, efficient light distribution, Min IP 65 rated, outdoor type with decorative light with impact and corrosion resistant with driver and lamp and with all accessories and connecting up with twin core twisted copper conductor cable of suitable size including lamp and making good disturbed surfaces complete all as specified and directed. (Make: Jaquar Cat No. LBLDCYL010XW or equivelant of make as per list of manufacturer)
25
-
-
S & F in repair 40mm bore, Steel water tubing, galvanised, medium grade with all fittings laid in trenches etc complete all as specified and directed.
80
-
-
S & F in repair 50mm bore, Steel water tubing, galvanised, medium grade with all fittings laid in trenches etc complete all as specified and directed.
20
-
-
S & F in repairs Rigid non-metalic PVC conduit (20mmdia) exclusive of boxes (junction/ treminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hook etc. complete all as specified and directed.
250
-
-
M & L for plain cement concrete (1:2:4), type B1 (using 20mm graded stone aggregate) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, including necessary formwork complete all as specified and as directed.
1.5
-
-
S & F in repairs voltage stabilizer of capacity 4KVA, working voltage 130-28 Volts, metal body with time delay system, wall mountable, built in thermal overload protection, low & high voltage cut-off protection, micro controller based design complete all as specified and directed. (Make: V-Gaurd Model No. VI 4170 PRIME or equivalent of make as per the list of manufacturer's)
20
-
-
S & F in repairs voltage stabilizer of capacity 5KVA, working voltage 130-28 Volts, metal body with time delay system, wall mountable, built in thermal overload protection, low & high voltage cut-off protection, micro controller based design complete all as specified and directed. (Make: V-Gaurd or equivalent of make as per the list of manufacturer's)
10
-
-
S & F in repairs stationary louvers suitable for exhaust fan of 300mm sweep made out of powder coated aluminium anodised sheet of Min 1mm thick with non removable blades fixed permanantly at 45 degree angle for protection from rain including aluminium wire mesh of suitable size for bird control Complete all as per the existing specification and as directed.
20
-
-
All as per Serial item No. 49 above but for exhaust fan of 450mm sweep complete ditto.
10
-
-
Supply, fix, installation and commissioning BLDC ceiling fan of less noise, silent operation, speed controlable by regulator, light colour, conforming to IS-374-2019, 1200 mm sweep, 230 Volts, BEE 5 Star rating, any Govt recognised Lab tested, power factor 0.94 Wattage and not more than 35 Watt, air delivery not less than 215cmm and all accessories such as down rod etc and connecting up with 1.5 Sqmm, PVC insulated, multistranded copper conductor cables from ceiling rose to fan and fixing in existing position including taking down existing unserviceable ceiling fan of any descriptions and deposited at MES store yeard complete all as specified and directed. (Note: Ceiling fan should have minimum 3 years manufacturer's warranty) (Make : USHA/Havell's/Bajaj/CG)
25
-
-
S & F Exhaust fan, 450 mm sweep, heavy duty, metal body 1400 RPM, AC, single phase, complete with all accessories and louver and electric connection including making necessary holes in walls including taking down old unserviceable exhaust fan from its existing position and removing to MES store yard complete all as specified and directed (Make : Havells, Model : TURBOFORCE FHEHDSPDB180 or equivelant of make as per List of Manufacturer's as approved)
8
-
-
S & F Exhaust fan, 300 mm sweep, heavy duty, metal body 1400 RPM, AC, single phase, complete with all accessories and louver and electric connection including making necessary holes in walls including taking down old unserviceable exhaust fan from its existing position and removing to MES store yard complete all as specified and directed (Make : Havells, Model : Ventil Air DS or equivelant of make as per List of Manufacturer's as approved)
10
-
-
S & F PVC body Exhaust fan, 250 mm sweep, AC, single phase, 1200 RPM complete with all accessories and electric connection including making necessary holes in walls including taking down old unserviceable exhaust fan from its existing position and removing to MES store yard complete all as specified and directed (Make : Havells, Model : Ventil Air DX or equivelant of make as per List of Manufacturer's as approved)
25
-
-
S & F in repairs 3 pin male top plug, 5 Amps for electrical fittings complete all as specified and as directed.
35
-
-
S & F in repairs 3 pin male top plug, 15 Amps for electrical fittings complete all as specified and as directed.
100
-
-
M & L for complete checking of LT panel board installed at various locations of MD ACCN block, checking of electrical connections such as thimbles, spring nuts, rubber gasket, window glass cover and refixed the same properly in position including replacement of such minor items (if any) as required at site complete all as directed by the Engr-in-Charge.
120
-
-
Material and Labour for preparation of old metal surfaces of Panel Boards after complete removal of existing painting over 10cm width or girth not otherwise described and applying two coats of enamel paint (1st quality) of simens grey colour over a coat red oxide zinc chrome primer and marking the Qtr No, Panel Board No in front side complete all as specified and directed by engineer in Charge.
(Note: Adjoing areas there to properly covered befor painting. Adjoing areas, floor, walls are to cleaned free of paint spillage after painting work. If Paint spill is not cleaned to match with exsting surface a panel recovery @ Rs.200/- per location will be made from payments due to the contractor).
150
-
-
S & F in repairs UPVC Panel cable trunking casing and capping of size 45x45mm including cover, bends, elbow, coupler, tees, internal and external bends, arranging existing cables/copper refrigerator pipe etc and making good the disturbed surfaces to match with existing surfaces complete all as specified and directed.
80
-
-
S & F in repairs UPVC Panel cable trunking casing and capping of size 75x75mm including cover, bends, elbow, coupler, tees, internal and external bends, arranging existing cables/copper refrigerator pipe etc and making good the disturbed surfaces to match with existing surfaces complete all as specified and directed.
70
-
-
S & F in repairs UPVC Panel cable trunking casing and capping of size 100x100mm including cover, bends, elbow, coupler, tees, internal and external bends, arranging existing cables/copper refrigerator pipe etc and making good the disturbed surfaces to match with existing surfaces complete all as specified and directed.
50
-
-
S & F in repairs UPVC Mini/Maxi trunking profile with cover of size 50x50mm including cover, bends, elbow, coupler, tees, internal and external bends, arranging existing cables/copper refrigerator pipe etc and making good the disturbed surfaces to match with existing surfaces complete all as specified and directed.
50
-
-
S & F in repairs UPVC Mini/Maxi trunking profile with cover of size 100x50mm including cover, bends, elbow, coupler, tees, internal and external bends, arranging existing cables/copper refrigerator pipe etc and making good the disturbed surfaces to match with existing surfaces complete all as specified and directed.
50
-
-
S & F in repairs UPVC Mini/Maxi trunking profile with cover of size 100x100mm including cover, bends, elbow, coupler, tees, internal and external bends, arranging existing cables/copper refrigerator pipe etc and making good the disturbed surfaces to match with existing surfaces complete all as specified and directed.
35
-
-
S & F in repair Hot- Dip Galvanised, powder coated, Perforated type Cable tray of size 150x25mm,18 SWG thick and standard length for fixing to wall including tee, cross, horizontal/vertical bends and reducer as required for fixing or arrangement of cables in side the cable tray with zip ties such as electrical cable after taking out of cables from existing conduits of any make and sizes and making good the disturbed surfaces to match with existing surfaces complete all as specified and directed.
10
-
-
S & F in repairs glow sign board box type, 100mm thick, with necessary Mild steel frame work of appropriate size, covered and printed on Poly Carbonate sheet having provision of sufficient Nos of LED tube light inside the box including connecting throught 3 Core 1.5 Sqmm circular PVC flexible wire of copper stranded conductor with LED fittings and tube rod complete including all necessary fixing accessories at site as required and directed including necessary electric connection complete all as specified and directed.
3.5
-
-
S & F in repair LED 30 Watt, Energy saving, environmental friendly, long life, one design for aesthetic consistancy in multi purpose application with SMD LEDs as light source with driver included, suitable for highlighting architectural features or Area lighting and with lamp and all accessories including mounting clamps, bolts, nuts and washers and copper conductor cable of suitable size to fittings of suitable length complete all as specified and as directed. (Make: Havell's Cat No. JETAQUANTOPLUSFLP30WLED757SYMLENS or equivelant of make as per list of manufacturer)
20
-
-
S & F in repairs 20W, LED Flame proof lights with IP 65 protection complete with all accessories all as specified and as directed.
(Make : Model no EXTN1LT8-16/20 of Crompton or equivalent of make as per List of Manufacturer's)
30
-
-
Supply and fixing in repair 40 Watt LED Bulkhead/ Wellglass luminaire, flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass with LED lamp fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size.complete all as specified and directed. (Make : CG Cat No. FWL1315-40-CDL equivelant model of make as specified in list of manufacturer).
6
-
-
Evaluation Notes How It Works ?