Military Engineer Services Tender

To know what Andhra Pradesh government has posted about any AP etender, Bidassist helps us to get a one-stop platform where a registered bidder can have access to the details on each and every eprocurement tender. There is no need to provide the details on the AP E-procurement website i.e. https://www.apeprocurement.gov.in as BidAssist helps us find the specific etender we're looking for. BidAassist has collated each and every Eproc Andhra Pradesh Tender on its website.

Military Engineer Services - MES Tender

Works
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date19 Nov 2024
Closing Date10 Dec 2024
Tender Amount₹ 45,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
All as per item No. 1.00 here-in-before but of GI / PPR pipe of size 15mm to 32mm bore dia.

20

-

-

... More
Labour only for attending breakdowns / leakage complaints of pipe lines of any type and description such as DI / CI / MS of size 200mm to 300mm bore dia on ground / floors inside buildings / on roof top of buildings etc by cleaning the pipe line surfaces, identifying the leakage / breakdown of pipe line, removing the damaged portion of pipe line by gas cutting / manual cutting as per site requirement, replacing with new pipe line / fittings / accessories by fixing / welding / threading as per site requirement and testing after completion for leak proof working complete all as specified and directed by Engineer-in-Charge. Note: Pipes along with fittings, accessories etc as required at site shall be measured and paid separately as "Supply Only" under relevant items of BOQ. However, the Quoted rate shall be inclusive of the following provisions:- (i) Breakdown / leakages should be attended and completed within 24 hours from the time of intimation to contractor by JE E/M / Engineer-in-Charge, failing which, penal recovery of Rs. 500 per hour shall be deducted from contractor dues. (ii) Sufficient manpower such as Plumber, Welder and helpers as per site requirement shall be provided by contractor to ensure the work to be completed within the time specified by Engineer-in-Charge. (iii) Necessary Tools, Plants, Safety Equipment, machinery and temporary lighting arrangement to work during night time etc as required at site shall be provided by the contractor.

1

-

-

... More
All as per item No. 5.00 here-in-before but of size 100mm / 150mm bore dia.

5

-

-

... More
All as per item No. 5.00 here-in-before but of GI / PPR pipe of size 40mm to 80mm bore dia.

10

-

-

... More
All as per item No. 5.00 here-in-before but of GI / PPR pipe of size 15mm to 32mm bore dia.

15

-

-

... More
Labour only for attending breakdowns / leakage complaints of pipe lines of any type and description such as MS / GI / PPR of size 63mm to 100mm bore dia on walls of buildings up to 3rd floor by cleaning the pipe line surfaces, identifying the leakage / breakdown of pipe line, removing the damaged portion of pipe line by gas cutting / manual cutting as per site requirement, replacing with new pipe line / fittings / accessories by fixing / welding / threading / Heating as per site requirement and testing after completion for leak proof working complete all as specified and directed by Engineer-in-Charge. Note: Pipes along with fittings, accessories etc as required at site shall be measured and paid separately as "Supply Only" under relevant items of BOQ. However, the Quoted rate shall be inclusive of the following provisions:- (i) Breakdown / leakages should be attended and completed within 24 hours from the time of intimation to contractor by JE E/M / Engineer-in-Charge, failing which, penal recovery of Rs. 500 per hour shall be deducted from contractor dues. (ii) Sufficient manpower such as Plumber, Welder and helpers as per site requirement shall be provided by contractor to ensure the work to be completed within the time specified by Engineer-in-Charge. (iii) Necessary Tools, Plants, Safety Equipment, machinery and temporary lighting arrangement to work during night time etc as required at site shall be provided by the contractor. (iv) Necessary scaffolding for working up to 3rd floor level of building.

10

-

-

... More
All as per item No. 9.00 here-in-before but of GI / PPR pipe of size 32mm to 50mm bore dia.

10

-

-

... More
Labour only for attending breakdowns / leakage complaints of pipe lines of any type and description such as MS / GI / PPR of size 63mm to 100mm bore dia on walls of buildings above 3rd floor and up to 6th floor of multistoried building of G+9 configuration by cleaning the pipe line surfaces, identifying the leakage / breakdown of pipe line, removing the damaged portion of pipe line by gas cutting / manual cutting as per site requirement, replacing with new pipe line / fittings / accessories by fixing / welding / threading / Heating as per site requirement and testing after completion for leak proof working complete all as specified and directed by Engineer-in-Charge. Note: Pipes along with fittings, accessories etc as required at site shall be measured and paid separately as "Supply Only" under relevant items of BOQ. However, the Quoted rate shall be inclusive of the following provisions:- (i) Breakdown / leakages should be attended and completed within 24 hours from the time of intimation to contractor by JE E/M / Engineer-in-Charge, failing which, penal recovery of Rs. 500 per hour shall be deducted from contractor dues. (ii) Sufficient manpower such as Plumber, Welder and helpers as per site requirement shall be provided by contractor to ensure the work to be completed within the time specified by Engineer-in-Charge. (iii) Necessary Tools, Plants, Safety Equipment, machinery and temporary lighting arrangement to work during night time etc as required at site shall be provided by the contractor. (iv) Necessary scaffolding for working up to 6th floor level of multistoried building.

10

-

-

... More
Labour only for attending breakdowns / leakage complaints of pipe lines of any type and description such as MS / GI / PPR of size 63mm to 100mm bore dia on walls of buildings above 6th floor and up to 9th floor of multistoried building of G+9 configuration by cleaning the pipe line surfaces, identifying the leakage / breakdown of pipe line, removing the damaged portion of pipe line by gas cutting / manual cutting as per site requirement, replacing with new pipe line / fittings / accessories by fixing / welding / threading / Heating as per site requirement and testing after completion for leak proof working complete all as specified and directed by Engineer-in-Charge. Note: Pipes along with fittings, accessories etc as required at site shall be measured and paid separately as "Supply Only" under relevant items of BOQ. However, the Quoted rate shall be inclusive of the following provisions:- (i) Breakdown / leakages should be attended and completed within 24 hours from the time of intimation to contractor by JE E/M / Engineer-in-Charge, failing which, penal recovery of Rs. 500 per hour shall be deducted from contractor dues. (ii) Sufficient manpower such as Plumber, Welder and helpers as per site requirement shall be provided by contractor to ensure the work to be completed within the time specified by Engineer-in-Charge. (iii) Necessary Tools, Plants, Safety Equipment, machinery and temporary lighting arrangement to work during night time etc as required at site shall be provided by the contractor. (iv) Necessary scaffolding for working up to 9th floor level of multistoried building.

10

-

-

... More
Supply only CI / DI fittings suitable for CI / DI pipe of size 80mm to 300mm bore and any type such as Bends (any type, radius and angle), tapers any type (straight, bend, increasing, decreasing or double socket etc), Tee pieces (single branch, "Y" junction, double branch, cross etc), caps and plugs etc, complete all as specified and directed by Engineer-in-Charge.

500

-

-

... More
Supply only DI Mechanical joint (MJ) collar with rubber ring complete suitable for CI/DI pipe line of size 80mm to 100mm bore dia with and including all jointing material complete all as specified and directed by Engineer-in-Charge.

3

-

-

... More
Supply only DI Mechanical joint (MJ) collar with rubber ring complete suitable for CI/DI pipe line of size 150mm bore dia with and including all jointing material complete all as specified and directed by Engineer-in-Charge.

3

-

-

... More
Supply only DI Mechanical joint (MJ) collar with rubber ring complete suitable for CI/DI pipe line of size 200 to 300 mm bore dia with and including all jointing material complete all as specified and directed by Engineer-in-Charge.

1

-

-

... More
Supply only MS clamp with rubber gasket, nuts, bolts and washers etc as required at site for pipe size 40mm / 50mm bore dia complete all as specified and directed by Engineer-in-Charge.

5

-

-

... More
Supply only MS clamp with rubber gasket, nuts, bolts and washers etc as required at site for pipe size 80mm / 100mm bore dia complete all as specified and directed by Engineer-in-Charge.

5

-

-

... More
Supply only MS clamp with rubber gasket, nuts, bolts and washers etc as required at site for pipe size 150mm / 200mm bore dia complete all as specified and directed by Engineer-in-Charge.

3

-

-

... More
Supply only MS clamp with rubber gasket, nuts, bolts and washers etc as required at site for pipe size 250mm / 300mm bore dia complete all as specified and directed by Engineer-in-Charge.

1

-

-

... More
Supply only Ductile iron pipe (Conforming to IS: 8329-2000), Centrifugally Cast (Spun) Pressure Pipe with Socket and Spigot ends suitable for Push-on-Joint including jointing material, duly applied with Zinc Coating with finishing layer of Bitumen on external surfaces and Cement Motor Lining with Bituminous Seal Coat on internal surfaces complete of size 100mm bore class K-9 complete all as specified and directed by Engineer-in-Charge.

12

-

-

... More
All as per item No. 21.00 here-in-before but of size 150mm dia bore

6

-

-

... More
All as per item No. 21.00 here-in-before but of size 200mm dia bore

6

-

-

... More
All as per item No. 21.00 here-in-before but of size 250mm / 300mm dia bore

6

-

-

... More
Supply only MS ERW Pipe P/E as Per IS:3589 Gr. 330, nominal bore 150 mm dia heavy grade complete all as specified and directed by Engineer-in-Charge.

20

-

-

... More
Supply only MS ERW Pipe P/E as Per IS:3589 Gr. 330, nominal bore 200 mm dia, wall thickness 5 mm complete all as specified and directed by Engineer-in-Charge.

12

-

-

... More
Supply only MS ERW Pipe P/E as Per IS:3589 Gr. 330, nominal bore 250 mm / 300mm dia, wall thickness 5 mm complete all as specified and directed by Engineer-in-Charge.

6

-

-

... More
Supply only MS slip-on weldable flange suitable for 150 mm NB pipe, complete all as specified and directed

6

-

-

... More
Supply only MS slip-on weldable flange suitable for 200 mm NB pipe, complete all as specified and directed

4

-

-

... More
Supply only MS slip-on weldable flange suitable for 250 mm / 300 mm NB pipe, complete all as specified and directed

2

-

-

... More
Supply only flange joint with rubber or fiber board gasket including suitable bolts, nuts and washers for 150 mm NB pipe, complete all as specified and directed

3

-

-

... More
Supply only flange joint with rubber or fiber board gasket including suitable bolts, nuts and washers for 200 mm NB pipe, complete all as specified and directed

2

-

-

... More
Supply only flange joint with rubber or fiber board gasket including suitable bolts, nuts and washers for 250 / 300 mm NB pipe, complete all as specified and directed

1

-

-

... More
Supply only Material for Run lead joint for 150mm NB CI/DI pipe, complete all as specified and directed

3

-

-

... More
Supply only Material for Run lead joint for 200mm NB CI/DI pipe, complete all as specified and directed

1

-

-

... More
Supply only Material for Run lead joint for 250 / 300mm NB CI/DI pipe, complete all as specified and directed

1

-

-

... More
Supply only CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings of size 20mm (OD) complete all as specified and directed by Engineer-in-Charge.

15

-

-

... More
Supply only CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings of size 25mm(OD) complete all as specified and directed by Engineer-in-Charge.

15

-

-

... More
Supply only CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings of size 32mm (OD) complete all as specified and directed by Engineer-in-Charge.

20

-

-

... More
Supply only GI pipe 40mm dia bore, medium grade with all fittings such as sockets, unions, bends, Tees, reducers, nipples etc complete all as specified and directed by Engineer-in-Charge.

12

-

-

... More
Supply only GI pipe 50mm dia bore, medium grade with all fittings such as sockets, unions, bends, Tees, reducers, nipples etc complete all as specified and directed by Engineer-in-Charge.

12

-

-

... More
Supply only GI pipe 80mm dia bore, medium grade with all fittings such as sockets, unions, bends, Tees, reducers, nipples etc complete all as specified and directed by Engineer-in-Charge.

6

-

-

... More
Supply only GI pipe 100mm dia bore, medium grade with all fittings such as sockets, unions, bends, Tees, reducers, nipples etc complete all as specified and directed by Engineer-in-Charge.

6

-

-

... More
Supply only 3-layer PP-R (Polypropylene random copolymer) of size 90 mm (OD) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings complete all as specified and directed by Engineer-in-Charge.

10

-

-

... More
All as per item No. 44 here-in-before but of size 63 mm (OD)

10

-

-

... More
All as per item No. 44 here-in-before but of size 32 mm (OD)

10

-

-

... More
Taking up or down steel tubing and connections, including cleaning for refixing or taking credit for the following pipe sizes complete all as specified and directed:-

-

-

-

... More
15mm dia bore

40

-

-

... More
20mm dia bore

50

-

-

... More
25mm dia bore

100

-

-

... More
40mm dia bore

50

-

-

... More
50mm dia bore

100

-

-

... More
80mm dia bore

150

-

-

... More
100mm dia bore

100

-

-

... More
Material and Labour for GI pipe, medium grade for the following pipe sizes with all fittings such as Sockets, Reducers, Unions, Tees, Nipples, Bends etc laid in trenches complete all as specified and directed :-

-

-

-

... More
15mm dia bore

10

-

-

... More
20mm dia bore

30

-

-

... More
25mm dia bore

50

-

-

... More
40mm dia bore

30

-

-

... More
50mm dia bore

80

-

-

... More
80mm dia bore

100

-

-

... More
100mm dia bore

50

-

-

... More
Material and Labour for GI pipe, medium grade for the following pipe sizes with all fittings such as Sockets, Reducers, Unions, Tees, Nipples, Bends etc fixed to walls / laid on floors etc complete all as specified and directed :-

-

-

-

... More
40mm dia bore

20

-

-

... More
50mm dia bore

20

-

-

... More
80mm dia bore

50

-

-

... More
100mm dia bore

50

-

-

... More
Supplying and laying of CPVC pipes of size 25mm(OD) SDR 11 & Plain CPVC SDR 11 fittings in trenches / fixed to walls / laid on floors etc complete all as specified and directed by Engineer-in-Charge.

20

-

-

... More
Supplying and laying of CPVC pipes of size 32mm(OD) SDR 11 & Plain CPVC SDR 11 fittings in trenches / fixed to walls / laid on floors etc complete all as specified and directed by Engineer-in-Charge.

100

-

-

... More
Material and Labour for Ductile iron pipe (Conforming to IS: 8329-2000), Centrifugally Cast (Spun) Pressure Pipe with Socket and Spigot ends suitable for Push-on-Joint including jointing material, duly applied with Zinc Coating with finishing layer of Bitumen on external surfaces and Cement Motor Lining with Bituminous Seal Coat on internal surfaces complete of size 100mm bore class K-9 laid in trenches including taking out existing unserviceable CI / DI pipe of any description complete all as specified and directed by Engineer-in-Charge.

60

-

-

... More
All as per item No. 52.00 here-in-before but of size 150mm dia bore

50

-

-

... More
All as per item No. 52.00 here-in-before but of size 200mm dia bore

25

-

-

... More
All as per item No. 52.00 here-in-before but of size 250mm / 300mm dia bore

25

-

-

... More
Material and Labour for 3-layer PP-R (Polypropylene random copolymer) of size 90 mm (OD) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings including taking out existing unserviceable PP-R / GI pipe of any description complete all as specified and directed by Engineer-in-Charge.

50

-

-

... More
All as per item No. 56.00 here-in-before but of size 63 mm (OD)

50

-

-

... More
All as per item No. 56.00 here-in-before but of size 32 mm (OD)

50

-

-

... More
Drilling and tapping cast iron water mains (in position) for branch connections of the internal dia 20mm and fixing Straight plain brass ferrules (or connecting screws) screwed both ends and fixed complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
Cutting existing steel tubing for the following pipe sizes and Screwing for alterations or additions (or lengthening screw on pipe to form connector) done in position without taking down complete all as specified and directed :-

-

-

-

... More
25mm dia bore

5

-

-

... More
40mm dia bore

3

-

-

... More
50mm dia bore

5

-

-

... More
80mm dia bore

3

-

-

... More
100mm dia bore

3

-

-

... More
Repacking stuffing box of sluice valve spindle including taking apart and reassembling of size 300mm dia, complete all as specified and directed

2

-

-

... More
Repacking stuffing box of sluice valve spindle including taking apart and reassembling of size 200mm dia, complete all as specified and directed

5

-

-

... More
Repacking stuffing box of sluice valve spindle including taking apart and reassembling of size 150mm dia, complete all as specified and directed

15

-

-

... More
Repacking stuffing box of sluice valve spindle including taking apart and reassembling of size 100mm dia, complete all as specified and directed

15

-

-

... More
Repacking stuffing box of sluice valve spindle including taking apart and reassembling of size 80mm dia, complete all as specified and directed

5

-

-

... More
Supply and replace Cast Iron sluice valve of size 200mm dia bore, having pressure rating PN 1.6, double flanged, non-rising stainless steel spindle with iron wheel conforming to IS:14846-2000 with jointing material i.e. new rubber gasket, GI nuts, bolts & washers etc of suitable size including taking down existing old unserviceable sluice valve complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
All as per item No. 66.00 here-in-before but of size 150mm dia bore

8

-

-

... More
All as per item No. 66.00 here-in-before but of size 100mm dia bore

6

-

-

... More
All as per item No. 66.00 here-in-before but of size 80mm dia bore

3

-

-

... More
Supply and replace Cast Iron Non Return Valve (NRV) 200mm NB with flanged ends swing type / ball type as per site requirement, including replacement of necessary packing material, GI bolts, nuts and washers etc including taking out existing unserviceable NRV of any description complete all as specified and directed by Engineer-in-Charge.

1

-

-

... More
All as per item No. 70.00 here-in-before but of size 150mm NB

5

-

-

... More
All as per item No. 70.00 here-in-before but of size 100mm NB

5

-

-

... More
All as per item No. 70.00 here-in-before but of size 80mm NB

3

-

-

... More
Supply and replace Cast Iron foot valve of size 200mm NB, flanged end ball type/ swing type including replacement of necessary packing material, GI bolts, nuts and washers etc including taking out existing unserviceable foot valve of any description complete all as specified and directed by Engineer-in-Charge.

1

-

-

... More
All as per item No. 74.00 here-in-before but of size 150mm NB

3

-

-

... More
All as per item No. 74.00 here-in-before but of size 100mm NB

3

-

-

... More
All as per item No. 74.00 here-in-before but of size 80mm NB

2

-

-

... More
Supply & Fix Brass foot valve of size 50mm NB taking out existing unserviceable foot valve of any description complete all as specified and directed by Engineer-in-Charge.

4

-

-

... More
Supply and fix Gun-metal gate valves of the following pipe sizes, with iron wheel head, screwed both ends for iron pipe including taking down existing unserviceable gate valve of any descriptioncomplete all as specified and directed :-

-

-

-

... More
80mm dia NB

15

-

-

... More
50mm dia NB

10

-

-

... More
40mm dia NB

5

-

-

... More
25mm dia NB

15

-

-

... More
20mm dia NB

5

-

-

... More
Supply and fix PP-R Gate valves (brass insert) of size 63mm(OD) as per requirement of the site complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
Supply and fix PP-R Gate valves (brass insert) of size 32mm(OD) as per requirement of the site complete all as specified and directed by Engineer-in-Charge.

3

-

-

... More
Supply and fix in replacement of CPVC ball valve of size 20mm (OD) complete all as specified and directed.

3

-

-

... More
Supply and fix in replacement of CPVC ball valve of size 25mm (OD) complete all as specified and directed.

3

-

-

... More
Supply and fix in replacement of CPVC ball valve of size 32mm (OD) complete all as specified and directed.

5

-

-

... More
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep and getting out in any type soil for laying pipes etc, complete all as directed by Engineer-in-Charge.

300

-

-

... More
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm, complete all as directed by Engineer-in-Charge.

250

-

-

... More
Removing excavated material to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point, complete all as directed by Engineer-in-Charge.

50

-

-

... More
Material and labour for cutting of existing road / hard standing up to 15 cm depth for laying of pipes, and making good the disturbed surfaces by providing PCC 1:2:4 type B-1 after laying of pipes and returning filling of soil, complete all as specified and directed by Engineer-in-Charge. Note:- Excavation and earth work below road / hard standing shall be measured and paid under relevant items.

50

-

-

... More
Material and labour for constructing valve chamber of internal dimensions 1mtr x1mtr x1.2 mtrs with 100 mm thick PCC (1:4:8 ) type D-2 for foundation, brick walls built in cement mortar (1:4 ), PCC 1:2:4 type B1 for coping , rendering in cement mortar 1:4, 15 mm thick internally and on exposed surfaces externally up to 15 cm above GL. Bottom PCC floor of the pit should be minimum 30 cms below the bottom surface of sluice valve flange to provide sufficient working space. The sluice valve and other fittings should be housed in center of the pit, the vertices of the pit should be in right angle and champhered .The top cover of the pit will be made out of 3mm MS sheet with angle iron frame made out of MS angle 50mm x 50 mm x 6 mm with MS hinges two Nos, and locking arrangements duly painted with two coats of water resistant synthetic enameled paint over one coat of red oxide primer, including demolition and taking out of existing broken valve chamber of any description complete all as specified and directed by Engineer-in-Charge.

5

-

-

... More
Material and labour for brick masonry with sub class B bricks, straight or curved on plan exc 6m mean radius in cement mortar 1:6 complete all as specified by Engineer-in-Charge.

5

-

-

... More
Material and labour for rendering 10mm thick cement plaster 1:6 on fair faces of brick work or concrete surfaces finished even and smooth (with out using extra cement) complete all as directed by Engineer-in-Charge.

30

-

-

... More
Dismantling or removing of centrifugal coupled / monoblock electric pump set of any make and model, of capacity 75 HP to 100 HP from its installed position by disconnecting suction and delivery lines, fixing dummy plate to both suction & delivery pipe, disconnecting electrical cables, earth strips and dismounting the pump and motor from base channel for overhauling / repair / rewinding of motor etc and reinstalling back in its original position, checking alignment and testing on completion for satisfactory performance complete all as directed by Engineer-in-Charge. Note: Overhauling, re-winding and spare parts required for repair shall be measured and paid separately under relevant items of BOQ.

2

-

-

... More
All as per Item No.92 here-in-before but capacity 40 HP to 50 HP.

8

-

-

... More
All as per Item No.92 here-in-before but capacity 20 HP to 30 HP.

3

-

-

... More
All as per Item No.92 here-in-before but capacity 10HP to 15 HP.

7

-

-

... More
All as per Item No.92 here-in-before but capacity 5HP to 7.5 HP.

6

-

-

... More
All as per Item No.92 here-in-before but capacity up to 3 HP.

2

-

-

... More
Disconnecting the electric cable and water mains, lifting the submersible pump set of any make and model of capacity up to 5 HP along with column pipe and submersible cable from Open Well / UG Sump / Shallow well having depth up to 15 mtrs for carrying out repairs / rewinding / replacement of defective submersible cable / replacement of rusted column pipe and re-installing and reconnecting the water mains and electric connections and testing on completion for satisfactory performance complete all as directed by Engineer-in-Charge. Note: Overhauling, re-winding and spare parts required for repair shall be measured and paid separately under relevant items of BOQ.

2

-

-

... More
Overhauling of pump set of any make and model by opening the pump and motor, replacing the worn out/defective spare parts, making good of shaft and shaft sleeve, cleaning internally, lubricating the rotating parts, re-assembling the pump and motor duly replacing all the packing material, worn out bolts, nuts, washers etc and testing for satisfactory performance of capacity 75HP to 100HP complete all as specified and directed by Engineer-in-Charge. Note: (i) Quoted rate shall deemed to be inclusive of necessary packing material, nuts, bolts & washers etc. (ii) Spare parts replaced shall be measured and paid separately under relevant items of BOQ.

2

-

-

... More
All as per Item No.99 here-in-before but capacity 40 HP to 50 HP.

8

-

-

... More
All as per Item No.99 here-in-before but capacity 20 HP to 30 HP.

3

-

-

... More
All as per Item No.99 here-in-before but capacity 10HP to 15 HP.

7

-

-

... More
All as per Item No.99 here-in-before but capacity 5HP to 7.5 HP.

6

-

-

... More
All as per Item No.99 here-in-before but capacity up to 3 HP.

2

-

-

... More
All as per Item No.99 here-in-before but open well Submersible pump set of capacity up to 5HP

2

-

-

... More
Shifting of pump set with motor of any type and capacity from any pump house located under AoR of GE (U-II) to civil workshop for repair / rewinding and bringing back with suitable mode of transport complete all as directed by Engineer-in-Charge.

10

-

-

... More
Cutting and removing burnt out winding from electric motor of any make and model and rewinding with super enameled copper winding wire of existing gauge and number of turns including necessary insulation, varnishing, heating etc and testing for satisfactory performance of capacity 75HP to 100HP complete all as directed by Engineer-in-Charge.

1

-

-

... More
All as per Item No.107 here-in-before but capacity 40 HP to 50 HP.

2

-

-

... More
All as per Item No.107 here-in-before but capacity 20 HP to 30 HP.

1

-

-

... More
All as per Item No.107 here-in-before but capacity 10HP to 15 HP.

2

-

-

... More
All as per Item No.107 here-in-before but capacity 5HP to 7.5 HP.

2

-

-

... More
All as per Item No.107 here-in-before but capacity up to 3 HP.

1

-

-

... More
Cutting and removing burnt out winding from submersible electric motor of any make and model and rewinding with water proof poly wrapped copper winding wires of existing gauge and number of turns and testing for satisfactory performance of capacity up to 5HP complete all as specified and directed by Engineer-in-Charge.

1

-

-

... More
Supply only the following spare parts suitable for existing centrifugal / monoblock pump sets and motors of any make and model as per site requirement, complete all as specified and directed :-

-

-

-

... More
Ball bearing DE/NDE suitable for 75 HP to 100 HP pump/motor

2

-

-

... More
Ball bearing DE/NDE suitable for 40 HP to 60 HP pump/motor

4

-

-

... More
Ball bearing DE/NDE suitable for 20 HP to 30 HP pump/motor

2

-

-

... More
Ball bearing DE/NDE suitable for 10 HP to 15 HP pump/motor

4

-

-

... More
Ball bearing DE/NDE suitable for 5 HP to 7.5 HP pump/motor

4

-

-

... More
Ball bearing DE/NDE suitable for up to 3 HP pump/motor

2

-

-

... More
Shaft sleeve suitable for 60 HP to 100 HP pump set

1

-

-

... More
Shaft sleeve suitable for 20 HP to 50 HP pump set

4

-

-

... More
Metallic hub for jaw / star coupling suitable for 60 HP to 100 HP pump set

2

-

-

... More
Metallic hub for jaw / star coupling suitable for 20 HP to 50 HP pump set

2

-

-

... More
Elastomeric insert (spider) for jaw / rubber star coupling suitable for 60 HP to 100 HP pump set

2

-

-

... More
Elastomeric insert (spider) for jaw / rubber star coupling suitable for 20 HP to 50 HP pump set

5

-

-

... More
Gland plate with gland rope suitable for 60 HP to 100 HP pump

2

-

-

... More
Gland plate with gland rope suitable for 20 HP to 50 HP pump

5

-

-

... More
Cable terminal plate suitable for 60 HP to 100 HP motor

1

-

-

... More
Cable terminal plate suitable for 20 HP to 50 HP motor

3

-

-

... More
External fan plastic body suitable for up to 15 HP motor

3

-

-

... More
External fan plastic body suitable for 20 HP to 50 HP motor

3

-

-

... More
External fan plastic body suitable for 60 HP to 100 HP motor

1

-

-

... More
CI Impeller with key suitable for 75 HP to 100 HP pump

1

-

-

... More
CI Impeller with key suitable for 40 HP to 60 HP pump

2

-

-

... More
CI Impeller with key suitable for 20 HP to 30 HP pump

2

-

-

... More
CI Impeller with key suitable for 10 HP to 15 HP pump

2

-

-

... More
CI Impeller with key suitable for 5 HP to 7.5 HP pump

2

-

-

... More
CI Impeller with key suitable for up to 3 HP pump

1

-

-

... More
Water seal suitable for up to 15 HP pump

5

-

-

... More
Water seal suitable for 20 HP to 50 HP pump

5

-

-

... More
Water seal suitable for 60 HP to 100 HP pump

2

-

-

... More
Supply only the following spare parts suitable for existing open well submersible pump and motor set of capacity up to 5HP of any make and model as per site requirement, complete all as specified and directed :-

-

-

-

... More
SS Rotor Sleeve

1

-

-

... More
GM Housing Bush

1

-

-

... More
Thrust bearing

1

-

-

... More
Water seal

1

-

-

... More
Stud, Nut & Bolt set

1

-

-

... More
Impeller shaft

1

-

-

... More
SS Impeller

1

-

-

... More
Shaft sleeve

1

-

-

... More
Neck Ring set

1

-

-

... More
SS Coupling assy with key

1

-

-

... More
Supply and replace pressure gauge of size 100mm dial, 0-10 Kg/CM2 complete all as specified and directed.

10

-

-

... More
Material and labour for preparation of old painted surfaces of pump set of capacity 75 HP to 100 HP and painting to electric pump and motor set and base frame with two coats of synthetic enameled spray paint of approved colour as per standard MES colour coding complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
All as per Item No.117 here-in-before but capacity 40 HP to 50 HP.

6

-

-

... More
All as per Item No.117 here-in-before but capacity 20 HP to 30 HP.

3

-

-

... More
All as per Item No.117 here-in-before but capacity 10HP to 15 HP.

6

-

-

... More
All as per Item No.117 here-in-before but capacity 5HP to 7.5 HP.

5

-

-

... More
All as per Item No.117 here-in-before but capacity up to 3 HP.

2

-

-

... More
Supply, laying and connecting PVC insulated and PVC Round Sheathed, Multicore Annealed Bare Copper Conductor (flexible) industrial cable of size 50 sqmm, 3 core for Voltage Grade 1100 Volt, Conforming to IS 694:2010 including taking down existing unserviceable cable of any description complete all as specified and directed by Engineer-in-Charge.

30

-

-

... More
Supply, laying and connecting PVC insulated and PVC Round Sheathed, Multicore Annealed Bare Copper Conductor (flexible) industrial cable of size 25 sqmm, 3 core for Voltage Grade 1100 Volt, Conforming to IS 694:2010 including taking down existing unserviceable cable of any description complete all as specified and directed by Engineer-in-Charge.

40

-

-

... More
Supply , laying and connecting Flat Three Core PVC Insulated & PVC Sheathed copper conductor Industrial Cable of size 16 sqmm, 3 core for Submersible Pump Motors 1100 Volt, conforming to IS 694 including taking down existing unserviceable cable of any description complete all as specified and directed by Engineer-in-Charge.

50

-

-

... More
Supply , laying and connecting Flat Three Core PVC Insulated & PVC Sheathed copper conductor Industrial Cable of size 10 sqmm, 3 core for Submersible Pump Motors 1100 Volt, conforming to IS 694 including taking down existing unserviceable cable of any description complete all as specified and directed by Engineer-in-Charge.

50

-

-

... More
Supply , laying and connecting Flat Three Core PVC Insulated & PVC Sheathed copper conductor Industrial Cable of size 4 sqmm, 3 core for Submersible Pump Motors 1100 Volt, conforming to IS 694 including taking down existing unserviceable cable of any description complete all as specified and directed by Engineer-in-Charge.

50

-

-

... More
M&L for preparing new or previously untreated steel surfaces of water pipe lines of any size, in any position, with two coats of synthetic enameled paint over one coat of red oxide primer with & including marking direction & name of feeder, complete all as directed by Engineer-in-Charge.

200

-

-

... More
Material and labour for Mild Steel base frames for pump sets, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed by Engineer-in-Charge.

200

-

-

... More
Supply and fix in replacement of Anti Vibration Mounting pads made out of composite elastomeric material and metal housing having skid protected elastomeric base suitable for floor installation of centrifugal coupled pump and motor set of capacity 75 HP to 100 HP without anchoring or grouting for safeguarding equipment against vibration, longitudinal and transverse stiffness complete all as specified and directed by Engineer-in-Charge.

12

-

-

... More
Supply and fix in replacement of Anti Vibration Mounting pads made out of composite elastomeric material and metal housing having skid protected elastomeric base suitable for floor installation of centrifugal coupled pump and motor set of capacity 40 HP to 60 HP without anchoring or grouting for safeguarding equipment against vibration, longitudinal and transverse stiffness complete all as specified and directed by Engineer-in-Charge.

18

-

-

... More
Supply and fix in replacement of Anti Vibration Mounting pads made out of composite elastomeric material and metal housing having skid protected elastomeric base suitable for floor installation of centrifugal coupled / monoblock pump and motor set of capacity 20 HP to 50 HP without anchoring or grouting for safeguarding equipment against vibration, longitudinal and transverse stiffness complete all as specified and directed by Engineer-in-Charge.

6

-

-

... More
Supply and fix in replacement of Anti Vibration Mounting pads made out of composite elastomeric material and metal suitable for floor installation of centrifugal coupled / monoblock pump and motor set of capacity up to 15 HP without anchoring or grouting for safeguarding equipment against vibration, longitudinal and transverse stiffness complete all as specified and directed by Engineer-in-Charge.

18

-

-

... More
M&L for PCC 1:3:6 type C2 using 40mm graded stone aggregate as in foundation, base concrete, hard standing etc complete all as specified and directed by Engineer-in-Charge.

3

-

-

... More
M&L for PCC 1:2:4 type B1 using 20mm graded stone aggregate as in foundation, base concrete, hard standing etc complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
Material and labour for Mild Steel Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed by Engineer-in-Charge.

200

-

-

... More
Taking down existing unserviceable spare parts and supply and replace following spare parts in AC, 3 Phase, 415 V, 50 Hz motor control panels complete all as specified and directed by Engineer-in-Charge.:-

-

-

-

... More
Power contactor suitable for existing star-delta starter of 75 HP motor.

1

-

-

... More
Power contactor suitable for existing star-delta starter of 30 - 40 HP motor.

3

-

-

... More
Power contactor suitable for existing star-delta starter of 10 - 15 HP motor.

3

-

-

... More
Thermal Overload Relay suitable for existing star-delta starter of 75 HP motor.

1

-

-

... More
Thermal Overload Relay suitable for existing star-delta starter of 30 - 40 HP motor.

2

-

-

... More
Thermal Overload Relay suitable for existing star-delta starter of 10 - 15 HP motor.

2

-

-

... More
Electronic Timer 3 - 30 sec

5

-

-

... More
Ammeter / Voltmeter selector switch

4

-

-

... More
LED indication lamp Red/Yellow/Blue/Green colour

15

-

-

... More
Push Button Switch for ON/OFF operations Red / Green colour

6

-

-

... More
Digital Voltmeter 0 - 500 V range

3

-

-

... More
Digital Ammeter 0 - 100 A range

3

-

-

... More
Supply and fix MCCB, 250 A, 36 KA, 4 pole, 415 V, 50 Hz with fixed thermal and magnetic release including taking down unserviceable MCCB of any description complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
Supply and fix MCCB, 160 A, 36 KA, 4 pole, 415 V, 50 Hz with fixed thermal and magnetic release including taking down unserviceable MCCB of any description complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
Supply and fix MCCB, 100 A, 25 KA, 4 pole, 415 V, 50 Hz with fixed thermal and magnetic release including taking down unserviceable MCCB of any description complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
Supply and fix MCCB, 63 A, 25 KA, 4 pole, 415 V, 50 Hz with fixed thermal and magnetic release including taking down unserviceable MCCB of any description complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
Supply, installation, testing and commissioning of Soft Starter for soft starting and stopping of 55KW / 75 HP, 3 phase, 415 V, 50 Hz, AC induction motor coupled with centrifugal pump with provision of bilt-in bypass contactor, essential motor protections against instantaneous over current, bypass overload, motor overload, phase imbalance, phase loss, phase sequence, excess start time, motor thermostat, supply fault, shorted SCR and LED indications for Ready / Tripped, Running/Starting-Stopping, Fault Code etc including taking down existing unserviceable starter of any description complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
All as per item No. 142.00 here-in-before but for 30 KW / 40 HP

2

-

-

... More
All as per item No. 142.00 here-in-before but for 22 KW / 30 HP

1

-

-

... More
Supply and fix fully Automatic Star Delta Starter in Sheet Steel enclosure / Panel mounting type suitable for 15 HP, AC, 3 Phase, 415 V, 50Hz induction motor incorporating Heavy Duty 4 Pole Contactor with wide band operating coil, Overload relay for motor protection and Electronic Star Delta Timer including taking down existing unserviceable starter of any description complete all as specified and directed by Engineer-in-Charge.

1

-

-

... More
Supply and fix DOL starter in Sheet Steel Enclosure incorporating Heavy Duty 4 Pole Contactor with wide band operating coil, Overload relay with manual re-set and yellow flag for trip indication suitable for up to 7.5 HP, AC, 3 Phase, 415 V, 50Hz induction motor including taking down existing unserviceable starter of any description complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
Supply, laying, connecting and testing of XLPE insulated, PVC sheathed, galvanized steel strip or wire armored, stranded aluminium conductor cable of size 50 Sqm, 3.5 core including taking down of existing unserviceable cable of any description complete all as specified and directed by Engineer-in-Charge.

100

-

-

... More
All as per item No. 147.00 here-in-before but of size 25 Sqm, 4 core

100

-

-

... More
All as per item No. 147.00 here-in-before but of size 16 Sqm, 4 core

50

-

-

... More
Material and labour for cleaning of Underground / Semi-underground / RCC over head reservoir using seven stage cleaning process as given below to the entire satisfaction of GE/Engineer-in-charge for following capacity of Sump / Tanks :- (i) DEWATERING : Dewatering shall be carried out through wash out pipe / using suitable dewatering pumps / sludge removal pump sets. (ii) SLUDGE REMOVAL : Removing of any type of sludge, accumulated mud, silt, sand, vegetation growth or any solid particles etc. from bottom surface and inner walls of tank with the help of sludge pumps or manually and disposing off the same to a distance exceeding 50 mtrs but not exceeding 100 mtrs away from the fencing/boundary wall of installation, and spreading in low lying areas. (iii) ALGAE REMOVAL : Removal of Algae, Calcinations etc from the walls with rotary cleaner/scrubber machine/wire brushes etc. (iv) INTERNAL WASHING : Washing of Walls and Ceiling with the help of high pressure jet cleaners using Sodium hypo chloride/Altoch mixed water (using 05% by Volume) (v) ANTI-BACTERIAL TREATMENT : Walls and ceiling to be sterilized with Anti Bacterial Solution (using 15 % by Volume of H2O2/silver ion) for making it bacteria free. (vi) VACUUM CLEANING : Complete removal of remaining sludge, accumulated mud, silt, sand with the help of vacuum cleaners. (vi) UV TREATMENT : Tank to be sterilized and disinfected with the help of UV lamp for minimum 01 hour to make bacteria free.

-

-

-

... More
Underground / Semi-underground sump of capacity 1.0 lakh gallons

5

-

-

... More
Underground / Semi-underground sump of capacity 75000/50000 gallons

1

-

-

... More
Underground / Semi-underground sump of capacity 2.5 lakh gallons

1

-

-

... More
Underground / Semi-underground sump of capacity 10000 gallons

1

-

-

... More
RCC Overhead Reservoir of capacity 2.0 Lakh gallons having staging height up to 20 meters above GL

1

-

-

... More
RCC Overhead Reservoir of capacity 1.0 Lakh gallons having staging height up to 20 meters above GL

2

-

-

... More
Notes for Item No 150.00 to150.06 : (i) Entire process of cleaning of OHR / UG Sump will be carried out through any certified agency only, who has vast experience in field of cleaning OHR / UG Sump and having all requisite plant & machinery including safety equipments, required for the same. The contractor must produce all credentials / work experience of cleaning agency and get approval of accepting authority for carrying out complete job of cleaning of OHR / UG Sump, before commencement of job. (iii) All the equipment/material required for cleaning of tank / sump will be brought by the contractor and no extra cost will be paid in this effect. (iv) The contractor must intimate at least one week in advance for cleaning of tank / sump and only after approval of Engr -in-charge/GE, the cleaning will be carried out. (v) The contractor must carry out all the process in such a way that the complete inside cleaning process as mentioned above must be finished in one day only or within stipulated time as decided by Engineer-in-charge to produce minimum disturbance to regular water supply to connected area. If contractor fails to restore the water supply within stipulated time, as decided by Engineer-in-charge, the penal recovery of Rs - 2000.00 per day will be recovered from contractor's dues.

-

-

-

... More
Notes for Item No 150.00 to150.06 : (vi) The contractor must cater for all safety arrangement i. e. safety belts/ helmet / safety harness, shoes etc for working man power and inspecting staff and no extra cost will be paid in this effect. (vii) The cost of cleaning area / grass cutting / removal of minor bushes / roots of dead tree within 05 meter radius from plinth protection of the tank / sump shall be deemed to be included in the unit rate quoted by the contractor. (viii) The branches of trees (up to 15 cm of girth) covering the roof of OHR / UG Sump or within 05 meter radius from plinth protection of the tank / sump shall be trimmed by and no extra cost will be paid in this effect.

-

-

-

... More
Material and labour for Flange Rubber gasket joints including GI nuts, bolts & washers of suitable size for CI/MS Raising Mains / Delivery pipe / washout pipe / Overflow pipe etc of size up to 200 mm dia of RCC Overhead Reservoir having staging height up to 20.0 meters fixed in vertical position by deploying sufficient man power and requisite T&P to ensure safety of OHR Structure and working party including cutting and removing old nuts, bolts, washers and rubber gasket complete all as specified and directed by Engineer-in-Charge. Notes : (i) One flange joint connecting two flanged pipes or pipe & valve will be measured as one unit. (ii) The contractor must cater for all safety arrangement i. e. safety belts/ helmet / safety harness, shoes etc for working man power and inspecting staff and no extra cost will be paid in this effect. (iii) The T&P, transport and other necessary equipment shall be arranged / brought by contractor to complete the job at site and no extra cost shall be paid to the contractor in this effect. (iv) The contractor must carry out all the process in such a way that the complete job / process as mentioned above for one OHR must be finished in one day or within stipulated time as decided by Engineer-in-charge to ensure minimum disturbance to regular water supply to connected area. If contractor fails to restore the water supply within stipulated time, as decided by Engineer-in-charge, the penal recovery of Rs - 2000.00 per day will be recovered from contractor's dues. (v) If, any kind of damage to OHR structure / connected valve or nearby bldg / plant / equipments etc, occurred during this process, the contractor shall repair / replace or make good the same as original at his risk and cost. No extra payment / cost will be paid in this effect.

5

-

-

... More
Testing of water samples as per IS:10500 (Amended up to date) from any NABL approved laboratory tested for its parameters such as physical, chemical, and biological characteristics by collecting water samples from various water supply installations under the AoR of AGE E/M No. I (U-II). Original Test reports shall be submitted to Engineer-in-Charge. Water testing shall be carried out once in month and / or as directed by Engineer-in-Charge.

60

-

-

... More
Material and labour for preparation of old painted surfaces of MS plates / LT panels and / or any description etc and painting with two coats of synthetic enameled paint of approved colour complete all as specied and directed by Engineer-in-Charge.

200

-

-

... More
Supply and fixing LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamps including taking down existing unserviceable flood light of any description complete all as specified and directed by Engineer-in-Charge.

5

-

-

... More
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections, one twin core cable flat or circular of size 10 sqmm stranded conductor including taking down existing unserviceable cable of any description complete all as specified and directed by Engineer-in-Charge.

100

-

-

... More
SCHEDULE OF CREDIT Note :- Amount of Rs. 1,77,865.00 indicated in Tender Documents as Schedule of Credit shall be deducted from the total quoted amount of BOQ.

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.