Get tender documents at just ₹200 per tenderKnow More
Search made simple for latest tendersNo hidden charges. No keyword restrictionsExplore Our Plansor Pay Per Tender

RITES Limited

Kolkata, West Bengal

  • Opening Date

    24 Jul 2019

  • Closing Date

    19 Sep 2019

  • Tender Amount

    ₹ 1,55,41,54,888

  • EMD

    ₹ 25,00,000

Summary

19/ot/hrbc-cable Repair/2019 Dt 24.07.2019

BOQ Items
ItemQuantityUnitsRateAmount
... more
Item Rate
0INR -
... more
TEXT #
0TEXT # -
... more
Item Description
0Units -
... more
Total Amount of BoQ2
0 -
... more
Amount after unconditional Rebate
1Nos -
... more
BoQ4
1Nos -
... more
BoQ5
1Nos -
... more
BoQ6
1Nos -
... more
BoQ7
1Nos -
... more
Conducting Fatigue and Ultimate strength tests of New cable system proposed for use in replacement accredited and approved International/National labs on representative samples of supplied cables including submission of reports as per FIB Bulletin 30. All tests will be executed as per relevant codes conforming to Technical Specification for cable in TS-I of Section-5 in presence of Engineer – in – Charge or his nominated representative. The rate will be inclusive of all taxes excluding GST. The rate also will include all costs of carriage of sample materials to laboratory, the cost of laboratory charges including submission of deliverable reports., cost of travel expenses of Engineer-in-charge or his representative to the place of laboratory. This Report will be verified and scrutinised by Technical Advisory Group as provided in Item No.1.018 of Schedule-IV.
1Nos 36000000
... more
Conducting Water tightness test of new cable system proposed for use in replacement at accredited and approved International/National laboratory on representative samples of supplied cable including submission of reports as per FIB Bulletin 30.All tests will be executed as per relevant codes conforming to Technical Specification for cable in TS-I of Section-5 and as per instruction and presence of Engineer – in – Charge or his nominated representative. The rate will be inclusive of all taxes excluding GST. The rate also will include all costs of carriage of sample materials to specified laboratory, the cost of laboratory charges, cost of travel expenses of Engineer-in-charge or his representative to the place of laboratory including submission deliverable of reports. This Report will be verified and scrutinised by Technical Advisory Group as provided in Item No.1.018 of Schedule-IV.
1Nos 8800000
... more
Protection and strengthening of stay cables except replaced cables as per Technical Specification for cable in TS-I of Section-5 by putting Anti Vandalism Tubes for protection against external injury up to 3m height and ‘Fire Protection up to 10 m vertical height of the cable from the top of deck level’. Structural steel material should conform to relevant IS codes etc. and Technical Specification for fire protection and anti vandalism of this Tender. All tests will be executed as per relevant codes and instruction of Engineer – in – Charge. The rate will be inclusive of (i) all taxes excluding GST,(ii) cost of all watch & ward, transportation, handling, procurement/hire etc. (iii) cost of lighting, scaffolding, Barricading, taking precautionary measures & all safety related issues, (iv) insurance of men & materials and all payments of workers / employees etc (v) all laboratory charges for testing complete in all respects excluding Fatigue & Ultimate Strength Test and Water Tightness Test (vi) any other relevant item of work as decided by Engineer-in-charge.This Scheme & Report will be verified and scrutinised by Technical Advisory Group as provided in Item No.1.018 of Schedule-IV.
140Nos 280000000
... more
For fixing as lateral restraint bearings in Pylon at Howrah end (P3) a) Maximum Horizontal Load Capacity 11310 KN & 12500 KN with longitudinal movement capacity of ± 250 mm and vertical movement ± 25 mm (Note: the entire group at one location using the same base/face plate shall be treated as one unit.)
2Each 4800000
... more
Removal of existing Bearings from the Piers (P-1,P-4) and Pylons(P-2,P-3) systematically/phasewise as per approved work program scheme/schedule ensuring safety of the Bridge structure as a whole.The work includes installation/fixing of new bearings at the appropriate aforesaid locations also.Necessary Jacking device,machineries are to be provided for completion of the job in all respect,conforming to the approved scheme/site condition. The job is to be executed ensuring safety of the Bridge structure along with the expansion joints both at Kolkata & Howrah end of the main Bridge structure as a whole. If there be any damage found anywhere in the Bridge during/after execution of work, the same has to be rectified/repaired/ stabilized solely/exclusively at the cost of the Contractor/Agency. The Unit rate will be inclusive of all taxes (except GST), duties, import Tax, watch & ward Cost, Transportation Cost, Handling Cost, Procurement/Hire Cost, pertaining to barricading, lighting, scaffolding, safety measures, insurance of men and materials, Insurance charges, payment of workers/Employees, Testing and Inspection Charges of materials. For implementing this item of work, no separate payment will be made for structural analysis or structural health monitoring system, if required.The rate will include submission of detail scheme testing report proof checked by International Consultant of repute like SchlaichBergerman& Partners, Germany or M/s Freemen Fox & Partner, UK or any other Consultant of repute approved by Engineer-in-charge. This Report will be verified and scrutinised by Technical Advisory Group as provided in Item No.16 of Schedule-IV. (a) Vertical Bearing
10Each 70750000
... more
b) Horizontal Bearing at Piers P1 & P4
8Each 11440000
... more
c) Horizontal Bearing at Pylons P2 & P3 (Note: The entire group at one location using the same base / face plate shall be treated as one unit.)
4Each 24108000
... more
(a) Supplying, Fitting, Fixing & Installation and operation of electrically operated cage lift for entire height of pylon of capacity 2 Ton with stopping arrangements at designated locations during construction stage. Two lifts will be operated simultaneously at two pylon locations and will be shifted to other pylon locations as per instruction of Engineer-in-charge. The rate includes all cost of shifting, re-fitting, power arrangement, cables, all safety measures and supporting structures, certification for safety, indemnity, lift operator & maintainer. After completion of the job the lift is to be handed over to HRBC. With these 02 Lifts the work is to be executed at 4 separate Pylon locations without any extra cost. The rate includes shuttering, staging, barricading all insurance, taxes, manpower (except GST). For hoisting erection no separate payment will be made. During Hoisting and erection and operation of lift necessary safety of the existing Pylons, superstructure, deck slab are to be ensured by the contractor. N.B: Seventy percent payment will be made after Supplying, Fitting& Fixing at 02 Pylons locations and the remaining Thirty percent payment will be made after dismantling of the aforesaid 02 Lifts from the concerned Pylons followed by Fitting, Fixing of old Lifts in New 02 Pylons locations.
2Nos 9908000
... more
(b) Providing Lift Man for Round the Clock basis (03 person per day basis).
36Month 1026000
... more
Hire charges of speed boat for twelve passengers for the entire period of Contract inclusive of operator, fuel, registration cost, safety certificates, and insurence costetc. The Contractor will indemnify RITES & HRBC from any mishap/accident. The use of speed boat will be as per direction of Engineer-in-charge.
36Month 7200000
... more
Supplying & providing of one no hired vehicle (Scorpio / Innova) for 1 shift of 12 hrs. each per day (1 Vehicle per day basis) with a limit of 3500 km for 1 Vehicle per month inclusive of all running costs, fuel, driver etc. to be used as per direction of Engineer-in-charge. N.B: Hired vehicle shall be provided on submission of specific requisition by Engineer-in-Charge.
36Month 2160000
... more
Hire charges of Technical Advisory Group consisting of 03 Eminent Experts from IISc/IIT/NIT/IIEST as approved by Engineer-in-charge for entire duration of the Contract to verify the different test reports, Replacement Scheme, Health Monitoring System etc for items related to Schedule-I to Schedule-V and submission of any technical advice required at site. The Scope of work includes periodical site visit as and when required. The cost will include all remuneration, fees, accommodation, travelling expenses etc. during site visit.
36Month 10800000
... more
Conducting Rebound Hammer Test at site for investigation of RCC Piers including Well and Well Cap (Non Destructive Test) including submission of Report
110Each 39600
... more
Conducting Ultrasonic Pulse Velocity Test at site for investigation of RCC Piers including Well and Well Cap (Non Destructive Test) including submission of Report
110Each 49799.2
... more
Conducting Covermeter Testing at site for investigation of RCC Piers including Well and Well Cap (Non Destructive Test) including submission of Report
16Each 4800
... more
Removing old paint from blistered painted surface of steel or other metal of Pylon, Girder, railingetc.by chipping including scraping and cleaning and exposing the originalsurface including scaffolding, staging.
2500Sqm 117500
... more
Priming 1 coat on steel surface of Pylon, Girder, Railing etc.with Red Oxide Zinc Chromate primer (IS: 2074) of approved quality including smoothening surfaces by sand papering etc by sand papering etc on steel surface complete in all respect as per direction of Engineer-in-charge including scaffolding, staging.
2500Sqm 72500
... more
Painting with superior quality aluminium paint of approved make andbrand including smoothening surface by sand papering etc. on steelsurface of Pylon, Girder, Railing etcas per satisfaction of Engineer in-charge conforming to IS Code : 2 coats as including scaffolding, staging.
85000Sqm 4845000
... more
Conducting Ultrasonic Testing of all 04 Pylons including submitting Report and Recommendation in format as approved by Engineer-in-charge.
10200Sqm 5610000
... more
Ultrasonic Thickness gauging with Digital Read out & capable of corrosion mapping of Pylon & Girder etc.
200Per Spot 100000
... more
Ultrasonic Flaw Detection of weld of main Bridge structure by Krautkramer USM - 25 instruments or equivalent with digital Display and Read out.
1000Per Spot 10000
... more
Visible dye liquid penetrant test on steel surface of Pylon & Girder etc.
200Per Spot 100000

NOTICE INVITING e-TENDERS General Manager (Proj )/RITES Ltd, Kolkata for and on behalf of HRBC, invites online percentage rate bids on two packet system for the following work: e-Tender No :.19/OT/HRBC-CABLE REPAIR/2019 dt 24.07.2019 Name of Work: Repair and Rehabilitation of 2nd Hooghly Bridge ( Vidyasagar Setu) ,Kolkata, India including Replacement of Stay & Holding Down Cables and Bearings etc. Estimated Cost: Rs 155.41 Cr (Approx.). Earnest Money: Rs.25,00,000/-. Period of Completion:36 (Thirty Six) months. Last time & date of submission of bid: upto 11.00 hrs. on 05.09.2019. Pre-Bid Meeting : 20.08.2019 The bid forms and other details can be obtained from the website https://etenders.gov.in/eprocure/app .Notice Inviting Tender is also available at website of HRBC (www.hrbc.in) . Amendment/Corrigendum, if any, shall be hosted online only.

Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.