Military Engineer Services Tender

... More
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.

Military Engineer Services - MES Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date28 Mar 2025
Closing Date29 Apr 2025
Tender Amount₹ 43,12,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Sand cushioning to underground cables provided with a layer of sand 8cm thick before laying the cable in trenches and 15cm thick after laying the cable in trenches complete all as specified.

1.62

-

-

... More
M&L for coloured & polished Chequered cement concrete tiles 30cm x 30cm x 25mm thick,set, jointed and pointed in neat cement slurry complete all as specified and directed by Engr - in - Charge.

40

-

-

... More
All as per item No.54 here – in – before but for oOne 3 pin socket outlet, 5 Amps, independent, with cables 1.5 sq. mm size.

27

-

-

... More
Taking down chowkhats or frame not exc 1.50 sqm each with shutter (without taking off shutters from the frame) complete all as specified and directed.

21

-

-

... More
M&L preparation of old wood or wood based surfaces of any description over 10 cm width or girth not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed.

153

-

-

... More
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of SPN 40 to 63 AMP and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and as directed.

1

-

-

... More
M&L 6 mm thick Asbestos cement plain building boards, fixed to timber frame work with screws all as specified and directed.

170

-

-

... More
S&F in repairs for sub main wiring along with earth wire of size two run of 6 sq mm + one run of 6 Sq mm earth wire single core PVC insulated cable with stranded copper conductor FRLS including drawing into 25 mm rigid non-metalic PVC casing caping on surface of wall/roof .(Note Three run of 6 Sqmm including one run of 25 mm of size casing caping shall be measured as one unit length including taking down of old servicible sub main wiring.

20

-

-

... More
Dismantling timber scantlings 40 Sqcm and over in section, in any position (framed work) all as specified and directed.

2.5

-

-

... More
Dismantling wrought iron or mild steel work of any description not otherwise provided all as specified and directed.

3.5

-

-

... More
S&F Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering, eaves board, ridges, hips,valley gutters, drip and straight flashing cladding to wall etc, fixed with self tapping screws all as specified and directed by Engr-in-Charge.

90

-

-

... More
M&L for preparation on newly plastered / previously untreated surfaces of wall and applying two coats of cement base paint complete all as specified and directed.

145

-

-

... More
Material and labour for cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armored, electric power cables (heavy duty 1100 Volts grade with stranded aluminium conductor of size 16 Sqmm 4 Core, including glands, lugs, nut, bolts, washers as required at site, testing complete all as specified and directed.

35

-

-

... More
S&F 35 mm thick (batten thickness) second class hard wood, glazed and Skelton shutters, open rebated and prepared to receive glass, gauge, etc , divided into squares, with plain chamfered or rounded, mitred and without sash bars, edges of framing plain, chamfered or rounded with cut mitred beds for securing glass etc, supplied and fitted to chowkhats complete all as specified and directed.(Note :- The dimension of the various components or parts of shutters shall be as specified in clause 8.24 (a) of MES SSR 2009 Part I)

12

-

-

... More
Removing excavated material not exceeding 50M and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified.

1.97

-

-

... More
M&L for 15 mm thick rendering in cement mortar (1:6) on stone masonry surfaces or surfaces other than fair faces of brick work, rendering finished even and smooth (without using extra cement) complete complete all as specified and directed.

95

-

-

... More
S&F 35 mm thick (batten thickness) second class hard wood , plain, framed panelled shutters (any number of panels), with panels of 12 mm thick timber flat on both sides (feather edged), or of 12mm thick veneered particle board medium density wood particle board with commercial face veneers complete all as specified and directed. (Note :- The dimension of the various components or parts of shutters shall be as specified in clause 8.24 (a) of MES SSR 2009 Part I)

12

-

-

... More
M&L for two coats of oil bound distemper over a coat of priming coat on newly prepared wall surfaces, including 1 mm thick layer of wall care putty (Birla white or equivalent) all as specified and directed..

95

-

-

... More
Supply and fixing Decorative, wall mounting, made up of Polycarbonate body suitable for 10 W LED lamp (B-2 base), Cat part No LHDL06160099 Model CITY - 3 Make- Havells or equivalent model of Philips/Bajaj / Crompton.

10

-

-

... More
M&L scrapping of existing treatment and applying two coats of 01 mm thick (each layer) of wall care putty (Birla white or equivalent) and then applying two coats of oil bound distemper over a coat of priming coat after preparation of wall surfaces complete all as specified and directed.

150

-

-

... More
Supply and fixing 415V 10KA 'C' curve miniature circuit breaker (MCB) of TPN 40 To 100 AMP in the DB complete with connection testing and commissioning all as specified and directed by Engr-in-Charge.

1

-

-

... More
S&F in repair stainless steel wire cloth 0.36mm nominal dia if wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.

45

-

-

... More
Supply and fixing Sheet metal enclouser Double door for MCB DB,s Phosphatised Powder Painted with bus bar 200 Amps rated Single pole and neutral linkof 12 way 240 Volts ACcomplete all as specified and as directed.

1

-

-

... More
Taking down cement plaster on brick or stone masonry surfaces of walls etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.

240

-

-

... More
Supply & Fixing Ceiling rose, 3 phase/PVC/polycarbonate, isolated body all as specified and as directed.

29

-

-

... More
M&L preparation of old steel surfaces of any description over 10 cm width or girth not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed.

105

-

-

... More
M&L for non skid ceramic coloured tiles 7 to 8 mm thick premium quality conforming to IS-13712, grade B-II(a) (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in vdertical surface such as skirtings, dados and riser to steps etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the surfaces of tile over and including 20 mm thick screed bed in cement mortar (1:6) complete all as specified and directed.

45

-

-

... More
M&L Sub class ‘B’bricks for covering to cable laid dry flat ,with width equal to the length of brick.

175

-

-

... More
S&F 30 mm thick (batten thickness) second class hard wood, glazed and Skelton shutters, open rebated and prepared to receive glass, gauge, etc , divided into squares, with plain chamfered or rounded, mitred and rebated sash bars, edges of framing plain, chamfered or rounded with cut mitred beds for securing glass etc, supplied and fitted to chowkhats complete all as specified and directed. (Note :- The dimension of the various components or parts of shutters shall be as specified in clause 8.24 (a) of MES SSR 2009 Part I)

47

-

-

... More
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed.

3.3

-

-

... More
Excavation in trenches/ foundation in soft/ loose soil not exc. 1.5 metre wide and n'exc. 1.50m deep for LT under ground cable/pole foundation and getting out including forming bottom surface to required level or slope, complete all as specified and directed by Engineer-in- Charge.

5.4

-

-

... More
Supply and fixing LED tube lights fitting, 4 feet long 1x 18W, 220V, AC decorative box type with holder including Removable poly cabonate LED tube light with inbuilt driver connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.

29

-

-

... More
Supply only integral water proofing compond all as specified and as directed.

19.63

-

-

... More
M&L for roughening surfaces of old concrete floor by picking,sweeping clean and washing down with water to remove dust etc complete all as specified and directed.

265

-

-

... More
S&F 3 mm thick sheet glass ordinary quality and glazing with oil putty in square not exc 0.50 sqm in each pane complete all as specified and directed.

30

-

-

... More
S&F mild steel framed work such as grills, grating etc with end of bars shouldered and/ or riveted or forged into spikes, framed guard bars,barred iron doors, ladders, framed balusters, walk ways, railings and similar work confirming to Fe-410-0 or Fe 310-0 complete all as specified and directed.

80

-

-

... More
S&F of joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc confirming to Fe 410-W (gde 250 quilty A) complete all as specified and directed.

350

-

-

... More
M&L 15 mm thick rendering on fair faces of brick work or concrete surface in cement mortar (1:4) on external wall finished even and fair mixed with integral water proofing compound @ 2% by weight of cement or in the manner specified by the manufacturer and in the proportions indicated all as specified and as directed. Note:-WPC will be measured and paid separately as supply only.

145

-

-

... More
Taking down chowkhats or frame exc 1.50 and not exc 4 sqm each with shutter (without taking off shutters from the frame) complete all as specified and directed.

4

-

-

... More
S & F in repairs LED retro fit lamp B-22 holder base with poly carbonate body and aluminium heat shrink of 9W complete CAT Part No : LHLDDBEBBI8R009 of havells or Equivalent of Crompton/Philips.

10

-

-

... More
M&L for PCC (1:3:6) type C-1 (using 20 mm graded crushed stone aggregate) as in bed blocks for grouting hold fasts , coping, filling in pressed steel chowkat or similar work including necessary form work as required complete all as specified and directed.

1.5

-

-

... More
M&L for 50 mm thick PCC (1:3:6) type C-2 using 40mm graded crushed stone agg as in plinth protection/ path laid slope of 1 in 12 and finshing cement concrete surface even and smooth without using extra cement with and including all necessary form work to divide the area in panels, finishing exposed edges fair or rounding or chamfering of exposed edges or as directed by engr -in-charge.

28.5

-

-

... More
Material and labour for point wiring with Copper conductor cables in PVC casing & caping PVC sheathed cable wiring 1100 volts grade (conforming to IS) drawn through PVC casing and capping in surface wiring , for one light point or one fan point controlled by one switch with cables 1.5 sq.mm size and connected to earth dolly and to be terminated in 1.6 mm thick pressed steel terminal boxes/ on PVC rectangular block with 3 mm thick plastic laminated sheet cover of suitable size (concealed type in permanent bldg and surface in temporary bldg or as directed ) for mounting fittings like switch, socket, fan regulator etc. with 3 mm thick laminated bakelite sheet cover complete all as specified or directed including testing on completion.

43

-

-

... More
S&F MS Plate of Fe 410 -W ( Gde -E-250) (Plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes including reveted, boled or welded attachment etc. complete all as specified and directed

175

-

-

... More
All as per item No.54 here-in-before but one 3 pin socket outlet, 5 Amps on the same board with other switches, with cables 1.5 sq. mm size.

4

-

-

... More
S & F Steel pipe glavanized light grade of 40 mm dia laid in trenches or under ground/floor or road of fixed with pole for protection of cable/ Earth sstrip including clams with bolts nuts and wasers complete ass as specifed.

12

-

-

... More
M&L preparation of new steel surfaces of any description over 10 cm width or girth not otherwise described and applying two coat of synthetic enamel paint over a coat of red oxide complete all as specified and directed.

120

-

-

... More
M&L for PCC (1:3:6) type C2 using (40mm graded aggregate) as in foundations, filling and mass concrete complete all as specified and directed.

2.7

-

-

... More
Supply and fixing LED building security light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed.

2

-

-

... More
M&L preparation of old decorated surfaces of walls, chajjas and applying two coats of cement base paint complete all as specified and directed.

165

-

-

... More
Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm buried directly in ground ( earth pit not less than 2.25 m deep bellow ground level ) with top edge of the plate not less than 1.5 m bellow normal ground level, connected to galvanized earth lead wire 4 mm dia. by means of galvanized iron or steel bolts , nuts , check nuts and washers, and connected to equipments as directed , including funnel with GI med grade watering pipe 20 mm bore , wire mesh , charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode , with concrete pit in PCC (1 : 3 : 6) type C-1 , 50 mm thick pre cast RCC (1 : 2 : 4) type B-1 cover slab reinforced with 8 mm dia deformed bar 15 cm C/C and suitable handle of 10 mm dia round bar ,GI medium grade pipe for earth lead protection including necessary excavation earth work in soft/loose soil and disposal of spoil to a distance n.exc. 50 m and necessary testing complete all as shown on electrical plate No. 3 of MES SSR Part-I and as directed.

1

-

-

... More
S&F 150 mm size Aluminium handles, cast type, anodised and fixed all as specified and directed.

50

-

-

... More
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of SP 5 To 32 AMP and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and as directed.

14

-

-

... More
Demolition of brick work or stone/boulder masonary buit in cement mortar including all quions ,arches ,pillars etc but excluding ashler facing dressed stone work and precast concrete and directed.

7.2

-

-

... More
M&L for non skid ceramic coloured tiles 7 to 8 mm thick premium quality conforming to IS-13712, grade B-II(a) (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the surfaces of tile over and including 20 mm thick screed bed in cement mortar (1:6) complete all as specified and directed.

265

-

-

... More
Supply and fix switch socket combination 2 in 1, 6A flush type all as specified and as directed.

31

-

-

... More
Excavation in post holes each n.exc 0.5 Cum getting out in Hard/Dense soils, returning filling in and ramming earth or broken rubble mixed with earth around in layers n.exc 25 cm and removing surplus soil to ad distance n.exc 50m and making good surface.

46

-

-

... More
Dismantling and taking down unserviceable main switches, DBs including sub main wiring etc. any type / size and making good disturbed surfaces to match with the existing finishes complete all as specified and as directed.

2

-

-

... More
Returning, filling in, including spreading , leveling , watering and well ramming in layer not exceeding 25cm each layer all as specified.

3.44

-

-

... More
Hacking out old broken glass (any thickness, size, quality or description) from metal frame including punching or drilling out old glazing pins/spring clips and providing and fixing new ones complete all as specified and directed.

25

-

-

... More
Supply and fixing Switch socket combination 6A/16A, 5 in 1, flush type universal all as specified and as directed.

8

-

-

... More
S&F 2nd class hard wood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered , put together with glue, pinned at joints complete all as specified and directed.

0.9

-

-

... More
Supply and fix switch piano, flush type single pole, one way 6 Amp all as specified and as directed.

43

-

-

... More
S&F Pre- painted galvalume aluminum zinc coating GI based steel sheet of approved profile of corrugation, 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws all as specified and directed by Engr-in-Charge.

545

-

-

... More
M & L for screed bed or bedding layer in Cement Mortar (1 : 6) of 20 mm thick for laying floor finishes complete all as specified and directed by Engr - in- Charge.

40

-

-

... More
S&F of 300 mm long aluminium alloy, anodised sliding door bolts with haps staple(bolt type), and fixing clips of sheet, cast or extruted sections and fixing bolt and sliding bolts of extruted sections or cast aluminium alloy and fixed complete all as specified and directed.

4

-

-

... More
Dismantling wall and ceiling boards (fiber, pulp, insulation etc) or insulation boards/slabs/blankets, any thickness including cover fillet complete all as specified and directed.

185

-

-

... More
S & F LED light fitting 1x9W/1X10W IP66 & IK09 integral LED Bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size including taking down old unserviceable fitting complete all as specified and as directed.

2

-

-

... More
S&F in repairs 2 nd class hardwood weather boarding, clean sawn,thickness 20 mm to 25 mm and rebated on thick edge to give 20 mm laps and fixed all as specified and directed.

115

-

-

... More
M&L for PCC 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate) as in surface channels, drains including all necessary form work complete all as specified and directed.

2.75

-

-

... More
All as per item No.54 here – in – before but for oOne 3 pin socket outlet, 5 Amps, independent, with cables 2.5 sq. mm size.

8

-

-

... More
M&L preparation of new wood or wood based surfaces of any description over 10 cm width or girth not otherwise described and applying two coat of synthetic enamel paint over a coat of pink primer complete all as specified and directed.

65

-

-

... More
Taking down unserviceable copper/aluminium point wiring of any description including all fittings (switch , socket, switch socket combination, lamp holder, ceiling rose, regulator etc.) and making good disturbed surfaces of wall, floor etc. to match with existing finishes complete all as specified and as directed.

82

-

-

... More
Supply and fixing Sheet metal enclouser Double door for MCB DB,s Phosphatised Powder Painted with bus bar 200 Amps rated Single pole and neutral linkof 8 way 240 Volts AC, concealed in wall complete all as specified and as directed.

1

-

-

... More
Dismantling of plain or corrugated steel sheeting, any gauge and thickness including Nainital or similar pattern roof coverings complete all as specified and directed.

395

-

-

... More
S&F mild steel work in tubular trusses, purlins including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S 1161-1979 grade St. 240 as in frame work for sun shade, roof, projection etc. complete all as specified and directed.

2515

-

-

... More
S&F false ceiling with powder coated exposed GI grid suspension system (E-Grid T-2430 or equvalent load carrying capacity with mid span deflection not exc. 1/360 span with hanger spacing of 1200mm c/c) consisting of main runner 3600mm long, cross Tee 1200mm/600mm long and wall angle. The main runners to be placed @ 1200mm, the cross Tee 1200mm will be inserted in the pre cut slots of main runner at a regular interval of 600mm to form a modular grid of 1200mmX600mm. Additional cross Tees of 600mm shall be placed perpendicular to the cross tee 1200mm long to finally form a grid of 600mmX600mm. Suspensor system (Grid) made out of GI sheet main Tee of size 23.5mmx38.50mmX0.36mm and cross Tee of size 23.5mmX23.5mmX0.36mm and angle size 19mmx19mmX0.36 mm. Grid of modular size 600mmX600mm shall be supported by 4 mm dia G.I. wire from purlins/soffit with and including 4mm thick high pressure steam cured non asbestos fiber cement designer ceiling board (Density1200Kg/Cum) of size 595mmX595mm, confirming IS 14862 & Type B Category III of ISO 8336, tested as per AS 1530 part 3 & BS-476 Part 4, 5, 6, 7 & 8, complete all as per manufacturer's instruction. (Make : Everest or equvalent as approved by GE)

175

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.