Military Engineer Services Tender
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date27 Jan 2025
Closing Soon17 Feb 2025
Tender Amount₹ 26,86,000
Costs
EMD
₹ 53,720Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_695033_1Tender No
8976/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Supply only starting capacitor of 80 to 100 MFD for split type air conditioners upto 2 TR capacity complete all as specified and directed.
(Make: EPCOS/Keltron/Asian/Tibcon/ Universal as approved)
15
-
-
... More
Supply only running capacitor of 30 to 60 MFD for split type air conditioners complete all as specified and directed.
(Make: EPCOS/Keltron/Asian/Tibcon/ Universal as approved)
10
-
-
... More
Supply only fan motor with blade suitable for out door unit split type air conditioners upto 2TR capacity complete all as specified and directed.
(Make: As per Sample as approved)
10
-
-
... More
Supply only blower fan motor with blade suitable for out door unit including capacitor, single phase, 230V, 50Hz, ISI marked for split type air conditioners upto 2TR capacity complete all as specified and directed.
(Make: As per Sample as approved)
8
-
-
... More
Supply only relay assembly for split type air conditioners upto 2TR capacity complete all as specified and directed.
(Make: As per Sample as approved)
(Note for item No.3.01 to 3.05 :- Materials of item No.3.01 to 3.05 to be incorporated in item No. 1.00 here-in-before)
8
-
-
... More
Repair only blower fan motor suitable for split type air conditioners upto 2TR capacity complete all as specified and directed.
5
-
-
... More
Repair only relay assembly for split type air conditioners upto 2TR capacity complete all as specified and directed.
5
-
-
... More
Supply and topping up of refrigerant gas (R-22 ) suitable for split/window AC/Refrigerator/deep freezer complete all as specified and directed. (Make: Mafron/Refron/FLORON as approved )
30
-
-
... More
Supply and topping up of refrigerant gas (R-407C ) suitable for AC plant/Refrigerator /Deep Freezer complete all as specified and directed. (Make: Mafron/Refron/FLORON as approved )
18
-
-
... More
Supply and topping up of refrigerant gas (R-32 ) suitable for split/window AC/Refrigerator/deep freezer complete all as specified and directed.
(Make: Mafron/Refron/FLORON as approved )
30
-
-
... More
Supply and topping up of refrigerant gas (R-134a ) suitable for split/window AC/Refrigerator/deep freezer complete all as specified and directed. (Make: Mafron/Refron/FLORON as approved )
10
-
-
... More
S&F of compressor of split type of air conditioner of 1.5 TR capacity of any make including initial filling of refrigerant gas to the required pressure and testing including taking down old unserviceable compressor complete all as specified and directed. (Make: As per sample).
5
-
-
... More
S&F of compressor of split type of air conditioner upto 2.0 TR capacity of any make including initial filling of refrigerant gas to the required pressure and testing including taking down old unserviceable compressor complete all as specified and directed. (Make: As per sample).
1
-
-
... More
S&F in repairs of copper tube of size 10mm (3/8 inch) dia including necessary soldering, flaring work and jointing testing in between indoor to outdoor units of split type AC complete all as specified and directed.
(Make:- Malasia/Camipro/Diamond/Star as approved)
10
-
-
... More
All as per item No 12.00 here-in-before but size of copper tube 6mm (1/4 inch) dia complete all as specified and directed.
10
-
-
... More
All as per item No 12.00 here-in-before but size of copper tube 12mm (1/2 inch) dia complete all as specified and directed.
10
-
-
... More
All as per item No. 12.00 here-in-before but size of copper tube 15mm (5/8 inch) dia complete all as specified and directed.
10
-
-
... More
Taking down old unserviceable copper condenser coil assembly from split type air conditioner upto 2.0 TR capacity & supply and fix copper condenser coil assembly with all accessories suitable to existing make/type and testing complete all as specified and directed.
7
-
-
... More
Repair only to condenser coil assembly suitable for split type air conditioner upto 2.0 TR capacity as per sample complete all as specified and directed.
5
-
-
... More
Taking down old unserviceable cooling coil assembly from split type air conditioner upto 2.0 TR capacity & supply and fix condenser cooling coil assembly with all accessories suitable to existing make/type and testing complete all as specified and directed.
(Make : As per sample)
7
-
-
... More
Repair only to cooling coil assembly suitable for split type air conditioner upto 2.0 TR capacity as per sample complete all as specified and directed.
5
-
-
... More
Supply and fixing of swing motor of 1.5/ 2.0TR capacity split type air conditioner with all accessories including taking down old unserviceable swing motor suitable to existing make/type and testing complete all as specified and directed.
(Make : As per sample)
12
-
-
... More
Repair only of swing motor suitable for split type air conditioner upto 2.0TR capacity as per sample complete all as specified and directed.
5
-
-
... More
S&F in repairs of 20mm dia transperant PVC heavy duty flexible pipe ISI marked with and including necessary clamps and nails for fixing the drain pipe for drainage of sweeling water of indoor unit of split ACs complete all as specified and directed.
(Make : Supreme/Prince/Prayag)
20
-
-
... More
Taking down old unserviceable 2-3 way refrigerant control valve from split air conditioner outdoor unit after evacuating of refrigrant gas and supply and fixing 2-3 way valve suitable for split type ACs of capacity upto 2TR and testing complete all as specified and directed.
(Make : As per sample)
8
-
-
... More
S&F for mild steel wall bracket (as per sample) suitable for fixing of out door unit of split type Air Conditioner with necessary nuts, bolts & washers and making good disturbed surfaces to match with the existing after taking down old unserviceable bracket complete all as specified and directed.
5
-
-
... More
Supply & fixing in repairs of universal strainer air filters cum drier suitable for upto 2 TR capacity Split Air conditioners of any make (as per sample) complete all as specified and directed.
12
-
-
... More
M&L for providing rubber foam heavy duty insulation tube over the existing copper tubing of any length at any location in replacement of worn out insulation including fixing with cable tie, clamping all as required at site, complete all as specified and directed.
10
-
-
... More
Taking down old unserviseable split type air conditioner indoor unit and and Supply and fixing indoor unit of the split type air conditioner 1.5 TR capacity with all accessories such as installation plate with screws, blower motor, swing motor, filters etc duly pre-wired including connecting to existing refrigerant piping, electrical connections, drain pipe and testing etc complete all as specified and directed. (Make: Carrier/LG/Hitachi/Blue star/ Voltas as approved)
7
-
-
... More
Taking down old unserviseable split type air conditioner outdoor unit and Supply and fixing outdoor unit of the split type air conditioner 1.5 TR capacity and complete with all accessories such as hermetically sealed compressor and condenser unit, capacitors, relays, fan motor, duly prewired including connecting to existing refrigerant gas piping, electrical connections and testing etc complete as in repair all as specified and directed. (Make: Carrier/LG/Hitachi/Blue star/Voltas as approved)
7
-
-
... More
Dismantling of window/split type air conditioner of capacity upto 2TR from the existing position and shifting to new altered location, complete indoor and outdoor units, refrigerant tubing, MS stand, stabilizer and cable etc and testing complete all as specified and directed.
10
-
-
... More
Supply only hand remote control for split type AC of capacity 1.5/2 TR with 2 Nos batteries, 1.5 Volt of size 'AAA' (suitable for existing make) and testing complete all as specified and directed.
6
-
-
... More
Taking out window type air conditioner for servicing and overhauling of capacity 1.5/2.0 TR of any make/type after disconnecting of electric connection, removing dust by using blower and cleaning the condenser coil and components by using water and caustic soda and replacing the spares like relay, Capacitors , thermostat, fan motor, blades & blower and also including carrying out servicing , overhauling and charging of refrigerant gas and testing including fixing back in its original location complete all as specified and directed. (Note :- (i) Spares will be measured and paid separately as "Supply only" under relevent item. (ii) Labour charge for taking down & fixing of "Supply only" materials are deemed to be included with quoted rate)
48
-
-
... More
Supply only of starting capacitor 80 to 100 MFD for window type air conditioner complete all as specified and directed. (Make : Concap/Keltron/Asian/Tesla/Sarda/Siemens/Tibcon as approved)
25
-
-
... More
Supply only of running capacitor 40/50/60 MFD for window type air conditioner complete all as specified and directed. (Make : Concap/Keltron/Asian/Tesla/Sarda/Siemens/Tibcon as approved)
20
-
-
... More
Supply only of relay contactor suitable for existing window type air conditioners upto 1.5/2 TR capacity complete all as specified and directed.
(Make: LG/Samsung/Carrier/Blue Star/Hitachi as approved)
15
-
-
... More
Supply only of fan motor with blade suitable for window type air conditioners upto 2 TR capacity complete all as specified and directed.
(Make: As per sample)
15
-
-
... More
Supply only of blower fan motor with blade including capacitor, single phase 230V, 50 Hz for window type air conditioner upto 2 TR capacity complete all as sepcified and directed.
(Make: Usha/AUE/Siemens/Keltron or equivalent any make with ISI marked )
15
-
-
... More
Supply only thermostat switch suitable for 1.5/2.0 TR window type AC complete all as specified and directed.
(Make : Honey Well/Indfors/Renutrol/Siemens/Daspars as approved)
16
-
-
... More
Supply only contactor, AC, 230 volts ,50Hz, suitable for Window ACs upto 2.00 TR capacity complete all as specified and directed.
(Make: As per sample)
(Note for item No.32.00 to 38.00 :- Materials of item No.32.00 to 38.00 to be incorporated in item No.31.00 here-in-before)
20
-
-
... More
Repair only of blower fan motor suitable for window type air conditioner upto 2 TR capacity as per sample complete all as sepcified and directed.
10
-
-
... More
S&F of any type hermetically sealed compressor of window type of air conditioner upto 2.0 TR capacity including initial filling of refrigerant gas to the required pressure and testing including taking down old unserviceable compressor complete all as specified and directed. (Make: As per sample).
10
-
-
... More
Taking down old unserviceable condenser coil assembly from window type air conditioner upto 2.0 TR capacity & supply and fix copper condenser coil assembly with all accessories suitable to existing make/type and testing complete all as specified and directed.
(Make : As per sample)
12
-
-
... More
Repair only condenser coil assembly for window type air conditioner upto 2.0 TR capacity as per sample complete all as specified and directed.
12
-
-
... More
Removing old unserviceable condenser cooling coil assembly from Window type air conditioner upto 2.0 TR capacity & supply and fix condenser cooling coil assembly with all accessories suitable to existing make/type and testing complete all as specified and directed.
(Make : As per sample)
15
-
-
... More
Repair only condenser cooling coil assembly of Window type air conditioner upto 2.0 TR capacity as per sample complete all as specified and directed.
12
-
-
... More
Replacement of corroded outer casing with base tray sheet of the window type air conditioner of capacity upto 2TR and supply and fix outer casing with base sheet made out of GI sheet suitable for window type air conditioner of capacity upto 2 TR complete all as specified and directed.
(Make : As per sample)
5
-
-
... More
Leak testing complete gas circulating system with dry nitrogen and evacuate and rectifying/arresting leakages by cutting, soldering, flaring work with nut, jointing of refrigerant tubing and charging of refrigerant gas to the required pressure in Windows AC upto 2TR capacity and testing complete all as specified and directed.
(Note : Refrigerant will be paid saparately)
15
-
-
... More
Repair of old PCB of split type/window AC Cap 1.5/ 2 TR as per existing make and model complete all as specified and directed.
15
-
-
... More
Supply and fixing in repairs of new PCB of split type/window AC Cap 1.5/ 2 TR non inverter type as per existing make and model complete all as specified and directed.
20
-
-
... More
Supply and fixing in repairs of new PCB of split type/window AC Cap 1.5/ 2 TR inverter type as per existing make and model complete all as specified and directed.
5
-
-
... More
S&F in repairs of front grill of window type AC with air filter (as per sample) complete all as specified and directed.M
(Make:- Voltas/LG/Blue Star or as per sample as approved)
5
-
-
... More
M&L for spray painting to window/ split type air conditioner of any type/make with two coats of synthetic enamel paint over a coat of red oxide primer after removal of existing treatment and preparation of surfaces and including removing dents complete all as specified and directed.
20
-
-
... More
Taking out water cooler for servicing and overhauling of capacity 40/80ltrs, 60/120ltr and 80/160ltrs of any make/type after disconnecting of electric connection, removing dust by using blower and cleaning all the components by using water and caustic soda, checking and replacing the spares like relay, capacitors, thermostat, PVC pipes, push cock/lift cock, float valves etc and also including carrying out servicing, overhauling and charging of refrigerant gas and testing and fixing back in its original location complete all as specified and directed.
(Note:- (i) Sparen will be measured & paid seperately as " Supply only" under relevent item. (ii) Labour charge for taking down & fixing of "Supply only" materials are deemed to be included with quoted rate.)
25
-
-
... More
Supply only capacitor of 10-20 MFD complete all as specified and directed.
(Make:Epcos/Keltron/Tibcon/Universal as approved)
15
-
-
... More
Supply only PVC out let drain connecting pipe of 15 mm bore with brass nuts and washers of length not exceeding 60 cm for connecting of water coolers complete all as specified and directed. (Make : As per sample)
10
-
-
... More
Supply only relay assembly suitable for water coolers of capacity complete all as specified and directed.
10
-
-
... More
Supply only thermostat switch for water coolers any type/make complete all as specified and directed. (Note for item No. 53.00 to 56.00 :- Materials of item No. 53.00 to 56.00 to be incorporated in item No. 52.00 here-in-before)
10
-
-
... More
S&F of blower fan motor for water cooler upto 160 Ltrs capacity and testing including taking down old unserviceable motor complete all as specified and directed. (Make : Usha/ AUE/ Siemens/ Keltron or equivalent as approved)
10
-
-
... More
S&F of fan motor with blade including capacitor, single phase, 230V 50Hz for water coolers of capacity 40/80 Ltrs & 60/120 Ltrs and testing including taking down old unserviceable motor complete all as specified and directed. (Make : Usha/ AUE/ Siemens/ Keltron or equivalent as approved)
10
-
-
... More
S&F for hermetically sealed compressor for water cooler 40/60 Litres capacity including initial filling of refrigerant gas to the required pressure and testing complete including taking down old unserviceable compressor complete all as specified and directed. (Make: As per sample).
8
-
-
... More
S&F for hermetically sealed compressor for water cooler 60/120 Litres capacity including initial filling of refrigerant gas to the required pressure and testing complete including taking down old unserviceable compressor complete all as specified and directed. (Make: As per sample).
2
-
-
... More
S&F for in repairs push cock/lifting cock of brass chromium plated 15 mm bore self closing type with back plate for water cooler of any capacity complete all as specified and directed.
5
-
-
... More
S&F in repairs for float valve assembly 15 mm dia with PVC body, polythene float suitable for water coolar complete all as specified and directed.
4
-
-
... More
Replacing the corroded portion of water cooler capacity 40/80ltrs, 40/120ltrs, 40/160ltrs capacity of any type/make and providing the same gauge sheet in corroded portion by bending/welding, soldering and painting the replaced portion to match with existing colour and providing base support to legs complete all as specified and directed.
10
-
-
... More
M&L for spray painting to water cooler/deep freezer/ refrigerator of any type/make with two coats of synthetic enamel paint over a coat of red oxide primer after removal of existing treatment and preparation of surfaces and including removing dents complete all as specified and directed.
15
-
-
... More
Leak testing complete gas circulating system with dry nitrogen and evacuate and rectifying/arresting leakages by cutting, soldering, flaring work with nut, jointing of refrigerant tubing and charging of refrigerant gas to the required pressure in water cooler of size 40/80ltrs, 40/120ltrs. 40/160ltrs cooling capacity and testing complete all as specified and directed.
(Note : Refrigerant will be paid saparately)
10
-
-
... More
Taking out Refrigerator for servicing and overhauling 165ltr to 352ltr capacity (single door/Double door type) of any make/type after disconnecting of electric connection and cleaning all the components, checking and replacing the spares like relay,capacitors, thermostat, Fused bulb and also including carrying out servicing, oiling, greasing, charging of refrigerant gas and testing complete all as specified and directed. (Note :- (i) Spares will be measured and paid separately as "Supply only" under relevent item. (ii) Refrigerant gas will be measured and paid separately as "Supply only".)
20
-
-
... More
Leak testing complete gas circulating system with dry nitrogen and evacuate and rectifying/arresting leakages by cutting, soldering, flaring work with nut, jointing of refrigerant tubing and charging of refrigerant gas to the required pressure in Refrigerator of size upto 352ltrs cooling capacity and testing complete all as specified and directed.
(Note : Refrigerant will be paid saparately)
10
-
-
... More
Supply only for relay assembly suitable for refrigerators of any type of capacity 165 to 352 litres complete all as specified and directed. (Make : As per sample)
(Note : Material to be incorporated in item No. 66.00 here-in-before)
10
-
-
... More
Supply only thermostat switch suitable for refrigerators of any type and any capacity complete all as specified and directed.
(Make : As per sample)
(Note : Material to be incorporated in item No. 66.00 here-in-before)
10
-
-
... More
S&F in repairs of cooling coil suitable for refrigerators of any type/ capacity 165 to 352 litres complete all as specified and directed.
10
-
-
... More
S&F in repairs of door gasket of best quality suitable for refrigerators of any type/ capacity 286/310/345 litres complete all as specified and directed.
10
-
-
... More
S&F in repairs of door handle of best quality suitable for refrigerators of any type/ capacity 286/310/345 litres complete all as specified and directed.
5
-
-
... More
S&F in repairs of bottle shelf of best quality suitable for refrigerators of any type/ capacity 286/310/345 litres complete all as specified and directed.
6
-
-
... More
S&F in repairs of vegetable tray of best quality suitable for refrigerators of any type/ capacity 286/310/345 litres complete all as specified and directed.
5
-
-
... More
S&F in repairs of cabinet shelves of best quality suitable for refrigerators of any type/ capacity 286/310/345 litres complete all as specified and directed.
5
-
-
... More
S&F in repairs of door lock of best quality suitable for refrigerators of any type/ capacity 286/310/345 litres complete all as specified and directed.
2
-
-
... More
S&F in repairs of condenser coil suitable for refrigerators of any type of capacity 165 to 352 litres complete all as specified and directed.
8
-
-
... More
Repair only of condenser coil suitable for refrigerators of any type of capacity 165 to 352 litres as per sample complete all as specified and directed.
5
-
-
... More
S&F in repairs of fan motor with blade suitable for refrigerators of any type of capacity 165 to 352 litres complete all as specified and directed.
8
-
-
... More
Taking down old unserviceable capilary copper tube of dia 0.031" (Inch) and supply and fix new capilary copper tube suitable for existing type/make/size complete all as specified and directed.
10
-
-
... More
S&F in repairs of heating element 20 to 40 watt for refrigerators of any capacity/ any make complete all as specified and directed. (Make: As per sample).
12
-
-
... More
Taking out Deep freezers for repairs/ servicing to Deep freezer of capacity 150 to 400 ltr of any make/type by replacing unserviceable compressor and other parts from the machine as directed including charging of Refrigerant gas after vacuuming and making system leak proof. Brazing the suction / discharge tubes where required and cleaning of Condensing unit to achieve proper cooling effect. Checking of electronic circuit of machine and repair where necessary by replacing electronic parts and changing of wirings with proper size PVC insulated wires as directed and testing complete. {Note :- (i) Compresssor shall be measured and paid seperately under relevent item) (ii) Spares will be measured and paid separately as "Supply only" under relevent item. (iii) Lobour charge for taking down and fixing of " Supply only" materials are deemed to be included with quoted rate.)
15
-
-
... More
Leak testing complete gas circulating system with dry nitrogen and evacuate and rectifying/arresting leakages by cutting, soldering, flaring work with nut, jointing of refrigerant tubing and charging of refrigerant gas to the required pressure in deep freezer of any size and cooling capacity and testing complete all as specified and directed.
(Note : Refrigerant will be paid saparately)
5
-
-
... More
Supply only of relay assembly suitable for deep freezer of any capacity complete all as specified and directed.
(Make : As per sample)
(Note : Material to be incorporated in item No. 82.00 here-in-before)
7
-
-
... More
Supply only of thermostate suitable for deep freezer of capacity 150 to 400 ltrs complete all as specified and directed.
(Make : As per sample)
(Note : Material to be incorporated in item No. 82.00 here-in-before)
6
-
-
... More
S&F in repairs of fan motor with blade single phase 230V AC 50Hz for deep freezer of any capacity complete all as specified and directed.
5
-
-
... More
S&F for rotary type compressor for deep freezer 150 to 400 litre capacity including initial filling of refrigerant gas to the required pressure and testing also including taking down old unserviceable compressor complete all as specified and directed . (Make: As per sample).
5
-
-
... More
Supply, Installation, commissioning and testing of voltage stabilizer for automatic operation single phase, wall mounted, copper wounded air cooled, with digital display desinged for input variation between 150 volt to 290 volt with output voltage 220 + 9% volt with calibration accuracy + 3% with high low cutoff, inteligent time delay facility of capacity 5.0KVA including taking down old unserviceable one complete all as specified and directed. (Make:- AE/APLAB/ ANREWYULE/ INDIAN TRANSFORMER & ELECTRICALS P. LTD./ V-GUARD/ VOLINA/ VINITEC)
20
-
-
... More
M&L for checking the leakage in both low and high side of the system by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leaks including S&F replacement of Teflon sealing of all refrigerant line valves like liquid lines valves/suction/ discharge valves of compressors, gland packages of all angle valves flaring of all connections framing welding etc complete for the AC plant of capacity 3 x 13 TR-Plant complete all as specified and directed.
1
-
-
... More
Servicing of Central type air conditioner plant of capacity 3x13 TR by replacing worn out gasket and parts, servicing to oil pump assembly, changing of compressor oil,descaling of condensor unit of AC plant ,making system in working condition, achieving proper cooling effect, rectify the other defects if any complete all as specified and directed. (Note:- (i) Existing refrigerant shall be taken out from the system, kept in cylinder and recharge on completion. (ii) Servicing/Descaling shall be carried out by authorized firm dealing in cooling applications or firm which has fixed the central AC plant.
1
-
-
... More
Repair only to compressor of Central air conditioner plant of capacity 3x13 TR by replacing worn out parts, making system in working condition, achieving proper cooling effect, rectify the other defects if any complete all as specified and directed.
1
-
-
... More
M&L in repairs of AHU motor suitable for AC plants with capacity 3x13 TR by dismounting it from weather making unit of AHU replacement of Bush, bearing by opening nuts bolts and removing electrical connections of the motor, replacement of V type Belt with new belt, replacement and alignment of shaft complete all as specified and as directed.
1
-
-
... More
S&F in repairs of Cast Iron butterfly valve (wafer Type) 50mm dia without lugs, lever operated, SS 304 Disc, Nitrile /EPDM rubber lining test pressure PN-10/PN-16 complete all as specified and as directed. (Make:- Zoloto/Advance/Leader/NVR/Audco)
2
-
-
... More
S&F in repairs of Cast Iron Y type strainer flanged ends with SS perforated sheed screen of size 50mm complete all as specfied and as directed.
(Make:- Zoloto/Advance/Leader/NVR/Audco)
1
-
-
... More
M&L for replacement for EWT/LWT sensor suitable for AFT tripping for AC plant of 2x13 AC plant complete all as specified and as directed.
1
-
-
... More
S&F of MS ERW pipe Heavy class 80 mm dia with bend socket etc complete including taking down old unserviceable piping and painting with two coats of synthtic enamel paint complete all as specified and directed.
(Make:- Jindal/ Tata/ Prakash/Bansal)
10
-
-
... More
S&F of MS ERW pipe Heavy class 65 mm dia with bend socket etc complete including taking down old unserviceable piping and painting with two coats of synthtic enamel paint complete all as specified and directed.
(Make:- Jindal/ Tata/ Prakash/Bansal)
10
-
-
... More
S&F of MS ERW pipe Heavy class 50 mm dia with bend socket etc complete including taking down old unserviceable piping and painting with two coats of synthtic enamel paint complete all as specified and directed.
(Make:- Jindal/ Tata/ Prakash/Bansal)
10
-
-
... More
M&L in replacement for Filter drier 3/8 inch, DML 163 compelte suitable for 13 TR AC plant complete all as specified and directed. (Make- Danfoss or eqvt as approved)
2
-
-
... More
M & L in repalcement Expansion valve thermostatic type suitable for 13 TR AC plant complete all as specified and directed. (Make- Danfoss or eqvt as approved)
2
-
-
... More
S&F in repair of Power contactor 3 pole of capacity ML-1.5, AC 3 rating 25 A with auxilary contact 2 NO + 2 NC complete all as specified and directed.
(Make :- L&T/Legrand/Siemens/ABB/C&S)
3
-
-
... More
Servicing, repair and maintenance of chiller panel board with repair and replacement of contactor of required capacity for AC plant of 13x3 TR complete all as specified and directed.
3
-
-
... More
S&F water pressure gauge of suitable size as per existing requirement for AC plant complete all as specified and directed.
(Make:- As per Sample as approved)
2
-
-
... More
Opening the upper sheet and side sheet of AHU’s of the plants for access to cooling coil, including M&L for washing/cleaning of cooling coil externally with mild acid (or caustic soda hot water solution) followed by water jet including cleaning/washing of air filters and descaling of cooling coil of AHU, re-fixing and changing of V Belt both set with necessary fitting and T&P for mounting complete all as specified and directed.
1
-
-
... More
Taking out the U/S motor and rewinding of motor capacity 2/3 HP with same gauge with super enameled copper wire including removing burnt winding cleaning of slots separation of rotor and starter making insulation to all joint and replacement of the following items complete all as specified and directed by Engr-in- charge. (Note:- (a) Replacement of ball bearing. Make: SKF-02 Nos, (b) Replacement of bush ,(c) Replacement of cooling fan - 01 Nos)
4
-
-
... More
Opening of pump 2/3 HP centrifugal for repair and replacement of following u/s parts including re-fixing of all the same and testing and commissioning complete all as directed.
(a) Replacement of gun metal bush (b) Replacement of ball bearing. (c) Replacement of oil seal -01 Nos. (d) Replacement of gland -01 Job
6
-
-
... More
S&F in repairs industrial metal clad socket, single phase, 240 volts, 20 Amps including suitable MCB connection complete as all as specified and directed. (Make:Legrand/L&T/Siemens/Havells as approved)
20
-
-
... More
S&F in repairs of 3 pin industrial plug top, ISI marked, suitable for industrial metal clad socket, single phase, 240 volts, 20 Amps including connection complete as all as specified and directed. (Make:Legrand/L&T/Siemens/Havells as approved)
5
-
-
... More
Taking down U/S submain wiring any type aluminium/copper conductor etc and making good the disturbed surfaces of walls/ floor etc matching with the existing surface.
550
-
-
... More
M&L for sub main wiring complete with 2 run of 6 sqmm single core copper conductor (ISI marked) cable 1100 volts grade, FR-LSH type, PVC insulated, unsheathed, flexible, multi stranded colour coded cables drawn through and including rigid PVC conduit of required size medium grade (MMS) with all connected accessories such as Bend, Tee, Elbow, Short pieces etc concealed in wall/roofs/floors and including one run of 6 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, FR-LSH type as earth continuity conductor connected to common earth dolly and including chease cutting and filling the same with cement mortar and finished with putty and making good the disturbed surfaces to match with existing surface as required for concealed work complete all as specified and directed.
300
-
-
... More
M&L for sub main wiring complete with 2 run of 4 sqmm single core copper conductor (ISI marked) cable 1100 volts grade, FR-LSH type, PVC insulated, unsheathed, flexible, multi stranded colour coded cables drawn through and including rigid PVC conduit of required size medium grade (MMS) with all connected accessories such as Bend, Tee, Elbow, Short pieces etc concealed in wall/roofs/floors and including one run of 4 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, FR-LSH type as earth continuity conductor connected to common earth dolly and including chease cutting and filling the same with cement mortar and finished with putty and making good the disturbed surfaces to match with existing surface as required for concealed work complete all as specified and directed.
(Note for item No. 110.00 & 111.00 :- (i)Two runs of cable with one run earth wire and PVC conduit shall be measured as one length. (ii) Extra length of cable required for connection to DBs shall be deemed to be included in the unit rate and shall not be measured separately. (iii) Earth wire shall run inside the conduit. (iv) Suitable color code of wire must be ensure for phase/netural/earth. (iv) All surface cutting/making good for wiring/switch board/junction box/DB etc are included with unit quoted rate.)
250
-
-
... More
Taking down carefully copper/aluminium point wiring (light, fan, bell, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, holders, regulators, sockets, light fittings and including making good the disturbed surfaces to match with the existing surfaces by applying white/ colour wash/distemper over applying of putty for smooth finish surface complete all as specified and directed.
90
-
-
... More
M&L for point wiring in (Surface) PVC Casing caping complete with FRLSH PVC insulated unsheathed 1100 Volts grade, conforming to IS-694, 2.5 sq mm (nominal area) multi stranded copper conductor cable drawn through in including non metallic medium grade PVC casing caping accessories, ISI marked, including all accessories on the surface of walls/floors/ceilings and making good the disturbed surface, with and including sunken type pressed steel/welded MS terminal box 1.6 mm thick bakelite laminated sheet top cover 3 mm thick and 2.5Sq mm copper earth continuity wire connected to earth dolly complete for one 6 pin 6/16 Amps socket outlet point controlled by one 16Amps switch on independent board complete all as specified and as directed.
25
-
-
... More
M&L for point wiring (concealed) complete with FRLSH PVC insulated unsheathed 1100 Volts grade, conforming to IS-694, 2.5sq mm (nominal area) multi stranded copper conductor cable drawn through in including non metallic medium grade rigid PVC conduit accessories, ISI marked, 19/20 mm dia including all accessories on the surface of walls/floors/ceilings and making good the disturbed surface, sunken type pressed steel/welded MS terminal box 1.6 mm thick bakelite laminated sheet top cover 3 mm thick and 2.5Sq mm copper earth continuity wire connected to earth dolly complete for one 6 pin 6/16 Amps socket outlet point controlled by one 16Amps switch on independent board complete all as specified and as directed.
25
-
-
... More
M&L for point wiring (concealed) complete with FRLSH PVC insulated unsheathed 1100 Volts grade, conforming to IS-694, 1.5sq mm (nominal area) multi stranded copper conductor cable drawn through in including non metallic medium grade rigid PVC conduit accessories, ISI marked, 19/20 mm dia including all accessories on the surface of walls/floors/ceilings and making good the disturbed surface, sunken type pressed steel/welded MS terminal box 1.6 mm thick bakelite laminated sheet top cover 3 mm thick and 1.5Sq mm copper earth continuity wire connected to earth dolly complete for one 5 pin 6 Amps socket outlet point controlled by one 6Amps switch on independent board complete all as specified and as directed.
40
-
-
... More
S&F of Socket outlet 2 in 1, 6 pin, 6 and 16 Amps, flush type, 240 volts all as specified and as directed.
50
-
-
... More
S&F switch piano flush button single pole one way 16 Amp 240 volts, all as specified and as directed.
50
-
-
... More
S&F Socket outlet, flush type 2 in 1, 5 pin, 6 Amps, 240 volts all as specified and as directed.
40
-
-
... More
S&F switch piano flush button single pole one way 6 Amp 240 volts, all as specified and as directed.
40
-
-
... More
Servicing to cooling tower for AC plant of existing capacity with replacement of filtration media like pebbles, carbon, coarse sand of FRP Vessel filtration system as per sample with fitting all connected accessories required at site and testing complete all as specified and directed . (Note:- Any pipe line work, pcc work required at site shall be included in quoted rate.)
1
-
-
... More
Attending water leak complaint of Air conditioning unit and solve the problrm after cleaning the cabinet, PVC drain pipe etc applying tape in joint and laying/sloping the drain pipe properly and fix the problem complete all as specified and directed.
(Note : (i) Drain pipe if required, will be measured and paid separately.
(ii) Non attendance/ completion of complaint shall be charged compensation @ Rs 1000/per complaints, however, on justified reason as desired by Engr-in-Charge, outstanding complaints shall be allowed another day for attending and completion without compensation.
20
-
-
... More
M&L for attending emergant complaints by experienced refrigerator mechanic i.e. Pertaining to Air conditioner any type, water cooler any type, refrigerator any type and other cooling appliances including carry out minor repairs and identification of faulty parts etc as required to the system in order/functional complete all as specifed and directed.
(Note : (i) Spare parts will be measured and paid separately under relevant items, complaint should be attended withing 24 Hours.
(ii) Non attendance/ completion of complaint shall be charged compensation @ Rs 1000/per complaints, however, on justified reason as desired by Engr-in-Charge, outstanding complaints shall be allowed another day for attending and completion without compensation.).
58
-
-
... More
S&F of flat sleek smooth 25A starter for AC including cutting fixing of concealed MS box with cover and finishing complete all as specified and directed.
(Make : As per sample)
10
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%