Military Engineer Services Tender
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date19 Oct 2024
Closing Date9 Nov 2024
Tender Amount₹ 45,00,000
Costs
EMD
₹ 90,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_680263_1Bid Award Id
ViewTender No
8601/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Excavating in post holes( or similar holes) each n exc 0.50 cum , getting out,returning filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in soft/ loose soil complete all as specified and directed.
110
-
-
Removing excavated material (soil) n exc 50m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and directed.
107
-
-
M&L for cement concrete 1:4:8 type D2,using 40mm graded stone aggregate as in foundations filling and mass concrete complete all as specified and directed.
0.33
-
-
M&L for PCC 1:3:6 type C2, using 40mm graded stone aggregate, as in foundation filling & mass concrete complete all as specified and directed.
26
-
-
M&L for PCC 1:2:4 using 40mm graded stone aggregate, type B2 as in foundation filling & mass concrete complete all as specified and directed.
0.2
-
-
M&L for brickwork with old size fly ash bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 complete all as specified and directed.
7
-
-
M&L well burnt old size sub Class ‘B’ bricks, laid in trenches for cable protection complete all as specified and as directed by the Engineer-in-Charge.
4500
-
-
M&L for MS work in posts and struts in fencing including cutting tops to shape as directed, drilling holes,notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc.,and similar work conforming to Fe-290 Gde E-165 and similar work complete all as specified and directed.
2710
-
-
S&F Mild steel screw bolts Diameter of neck in 5 to 10mm (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long complete all as specified and directed.
40
-
-
M&L for Mild steel round bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
550
-
-
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc.including provission of binding wire complete all as specified and directed.
650
-
-
S&F Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails strain- ing bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. complete all as specified and directed. (each line wire to be measured)
12.5
-
-
Supply only Chain link MS galvanisd fencing, any size or type complete all as specified and directed.
1950
-
-
M&L for 75mm thick PCC 1:3:6 type C1 (Using 20mm graded stone aggregate) as in plinth protection finished even and smooth without using extra cement.Joints to be given at every 3m interval and corners of buildings and fitted with bituminious mastic or equivalent filler complete all as specified and directed.
120
-
-
M&L for 75mm thick PCC type D2,1:3:6 using 40mm graded stone aggregate as in sub base floor complete all as specified and directed.
185
-
-
M&L for providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks,lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; complete all as specified and directed.
150
-
-
M&L for pre polished coloures cement concrete chequred tile with grey cement and pigment of approved quality size 300X300X 25mm thick on floors over and including 20 mm thick screed bed cement mortar 1:6 set and jointed in neat cement slurry and pointed with colour to match the tiles complete all as specified and directed.
185
-
-
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and directed.
120
-
-
M&L for preparation of old undecorated surface of wall and applying one coats of white wash complete all as specified and directed.
260
-
-
M&L preparation of old plastered surfaces of ceiling and chajjas and applying one coat white wash complete all as specified and directed.
40
-
-
M&L for two coats of synthetic enamel paint over one coat of red oxide on new steel surfaces of any description over 10cm in width or girth including preparation of surfaces complete all as specified and directed.
50
-
-
M&L for in repair 80mm dia GI pipe Light grade with all necessary fittings laid in trenches, fixed to wall/pole/under road/floor etc for cable protection complete all as specified and as directed.
16
-
-
M&L for in repair 50mm dia GI pipe Light grade with all necessary fittings laid in trenches, fixed to wall/pole/under road/floor etc for cable protection complete all as specified and as directed.
20
-
-
Demolition of Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings,dressed stonework and precast concrete articles complete all as specified and directed.
7
-
-
Dismantling of stone slabs and tiles of any description or thickness in floors, approachs, dado/Partitions laid bedded and pointed in any mortar etc complete all as specified and directed
33.5
-
-
Demolition of cement concrete in ground floor and paving n.exc 15 cm thickness( below or above ground level) complete all as specified and directed.
22.88
-
-
Dismantling of fencing any type complete all as specified and directed.
650
-
-
Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion and making good disturbed ground Posts embedded in Concrete, brick work, masonry, etc complete all as specified and directed.
363
-
-
M&L for rendering 15 mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces and finishing surfaces even and smooth without using extra cement complete all as specified and directed.
181
-
-
M&L for preparation of newly plastered surfaces of walls and applying two coats of cement base paint over a coat of alkai registant primer complete all as specified and directed.
90
-
-
M&L for preparing old plastered surface of wall and applying one coat of cement base paint by brooming down, scraping, cleaning and removing smoke soot, moulds, moss and efflorescence complete removal of existing treatment complete all as specified and directed.
450
-
-
M&L for preparation of new undecorated surface of wall and applying two coats of white wash complete all as specified and directed.
90
-
-
M&L for sand cushioning for protection of underground cable, consolidated and compacted with clean dry sand complete all as specified and directed.
74.12
-
-
M&L for Steel tubular swaged poles 9.0 metres long complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-31 complete all as specified and directed.
3
-
-
M&L for Cross arms, bracings, supports,clamps and back plates fabricated from structural steel sections including nuts, bolts, washers,welding, bending cold or hot,drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminum paint complete all as specified & directed.
1
-
-
M& L for Pin type, porcelain, vitreous, white, brown or green insulator, 100mm height, 65 mm dia for 1100 volts grade including one galvanised mild steel spindle, two galvanised iron washer and one galvanised iron nut, fixed in repairs complete all as specifed and directed.
20
-
-
M&L for Shackle type insulator porcelain, vitreous, white, brown or green insulators 100mm dia and 115 mm height for working pressure 1100 volts including galvanised mild steel strap 31 x 3mm size, washers, 14mm dia insulator bolts, washers & nuts , fixed in repairs complete all as specifed and directed.
10
-
-
S&F in repairs MCCB 200 Amps, 4 Pole, 415 V, adjustable type, with breaking capacity 36 KA,Ics=100 % ICU including spreader terminals & connected accessories both ends complete all as specified and directed.
3
-
-
S&F in repairs MCCB 250 Amps, 4 Pole, 415 V, Adjustable type, with breaking capacity 36 KA, 100 % ICU including spreader terminals & connected accessories both ends complete all as specified and directed.
3
-
-
S&F in repairs MCCB 320 Amps, 4 Pole, 415 V, adjustable type, with breaking capacity 36 KA, Ics=100% ICU including spreader terminals & connected accessories both ends complete all as specified and directed.
2
-
-
M&L for stay assembly complete comprising of 7/3.15 galvanised stranded stay wire of required length, fixed to pole with and including FI clamps 50x6mm, bolt, nuts washers, GI stay rod 20 mm dia and 1800 mm long stay bow 400x14 mm, GI steel plate 300x300x6mm, loop insulator of size 90x140mm clearance hole 16 mm including two coats of aluminium paint over a one coat of red oxide primer on exposed mild steel work all as shown in Electrical Plate no 1 of SSR part-I 2009 on page No 495 complete all as specified and directed, ( Note : Excavation & PCC works shall be measured and paid separately).
3
-
-
Supply and stringing ACSR conductor of any size to LT over head line as directed including fixing to insulators with proper size of binding wire complete all as specifeied and as directed.
1
-
-
Re-streching of existing ACSR conductor of any size any type as required sag fixed on OH line & insulators/cross Arms on poles properly binding on insulator with alumminum conductor.
3
-
-
M & L for XLPE insulated GI wire/Strip armoured Electric power cable (Heavy duty) with stranded Aluminium conductor 1100 Volts grade, cross sectional area 185Sqmm 3.5 core laid in trench/pole/on wall completer all as specified and as directed.
50
-
-
M & L for XLPE insulated GI wire/Strip armoured Electric power cable (Heavy duty) with stranded Aluminium conductor 1100 Volts grade, cross sectional area 120Sqmm 3.5 core laid in trench/pole/on wall completer all as specified and as directed.
100
-
-
M & L for XLPE insulated GI wire/Strip armoured Electric power cable (Heavy duty) with stranded Aluminium conductor 1100 Volts grade, cross sectional area 95Sqmm 3.5 core laid in trench/pole/on wall completer all as specified and as directed.
100
-
-
M & L for XLPE insulated GI wire/Strip armoured Electric power cable (Heavy duty) with stranded Aluminium conductor 1100 Volts grade, cross sectional area 70Sqmm 3.5 core laid in trench/pole/on wall completer all as specified and as directed.
100
-
-
M & L for XLPE insulated GI wire/Strip armoured Electric power cable (Heavy duty) with stranded Aluminium conductor 1100 Volts grade, cross sectional area 50Sqmm 3.5 core laid in trench/pole/on wall completer all as specified and as directed.
100
-
-
M & L for XLPE insulated GI wire/Strip armoured Electric power cable (Heavy duty) with stranded Aluminium conductor 1100 Volts grade, cross sectional area 35Sqmm 3.5 core laid in trench/pole/on wall completer all as specified and as directed.
100
-
-
M & L for XLPE insulated GI wire/Strip armoured Electric power cable (Heavy duty) with stranded Aluminium conductor 1100 Volts grade, cross sectional area 25Sqmm 4.0 core laid in trench/pole/on wall completer all as specified and as directed.
200
-
-
M & L for XLPE insulated GI wire/Strip armoured Electric power cable (Heavy duty) with stranded Aluminium conductor 1100 Volts grade, cross sectional area 16Sqmm 4.0 core laid in trench/pole/on wall completer all as specified and as directed.
200
-
-
Taking out old/Unsv damaged existing steel/concrete poles of any size/length from existing position including necessary earthwork like excavation,returning filling,removal of earth etc and demolition of PCC foundation and removing the same from site complete all as specified and directed.
3
-
-
Dismantling of ACSR or AAC conductor from LT service feeder or distribution line complete all as specified and directed.
1
-
-
Dismantling cross arms of MS channels or angle sections etc complete all as specified and directed.
1
-
-
Dismantling insulators any type any sizes complete all as specified and directed.
68
-
-
Dismantling stay assembly complete.(demolition of concrete, etc. and excavation measured separately) complete all as specified and directed.
3
-
-
S&F in repairs MCCB 63 Amps 4 pole, 415 V, breaking capacity 16 KA,Ics=100% ICU including spreader terminals & connected accessories both ends complete all as specified and directed.
4
-
-
S&F in repairs MCCB 100 Amps 4 pole, 415 V, breaking capacity 16 KA,Ics=100% ICU including spreader terminals & connected accessories both ends complete all as specified and directed.
3
-
-
S&F in repairs MCCB 160 Amps 4 pole, 415 V, breaking capacity 36 KA,Ics=100% ICU including spreader terminals & connected accessories both ends complete all as specified and directed.
4
-
-
M&L for earthing complete with galvanised steel earth plate electrode 60×60cm×6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised iron 25x4mm earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No.3 connected to earthing test point including testing on completion including watering GI pipe 20mm bore medium grade, 15mm bore light grade GI pipe for protection of earth lead including provision of concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 54 cm x 54 cm x 5 cm including 8mm dia TMT bars both ways @ 15cm centre to centre with one handle for lifting made out of 8mm dia MS bar, funnel & wire mesh, excavation and earth work in any type of soil complete including dismantling existing all as specified & directed.
20
-
-
M&L for repair, serviceing and replacement of unserviceable accessories of LT Panel any make type/size including welding, brazing and drilling work etc complete all as specified and directed.including the followings.
(a) Tightening of all loose conectiont of cable inside the panel and welding the broken door of the panel.(b) Clean all the rusted busbar through emery paper and fixing insulation heat shrink sleeves through out the busbar including strip connected with out going MCCB.
(c) Cut the damage insulation portion end of cable inside the panel and reconnecting its into positions after fixing the end termintion/Sleeves complete with suitable size of aluminium lugs and stainless steel nut bolts including excavation and earth work in any type of soil for taking out the existing cable loop to fixing the end joint or reconnection in position.
(d) Repair/Replacement of burn/unserviceable voltmeter, ammeter,indication lamp including control wiring of the panel between voltmeter, Ammeter and their selector switch and CTs .
(e) Repair/Replacement of all burn lugs inside the panel.(f) Replacement of all the GI rusted nut, bolts,and washers with made of stainless steel nuts, bolts and washers.(g) Clean the dust inside the panel by air blower/vaccum cleaner complete.
Note : (a) The cost of nut bolts, washers, insulation tape, lugs etc essentially required to make the panel serviceable shall be deemed to be included in the quoted rate. (b) Other spare parts/accessories shall measured and paid separately under relevant items of schedule.
12
-
-
Supply only epoxy type insulator for support of busbar grade 1100 volt as per existing size complete all as specified and directed.
38
-
-
Material only for control wiring of the panel with 1.5 sq mm multistranded, PVC insulated copper conductor 1100 Volt grade FRLS cable complete all as specified and directed.
130
-
-
Supply only LED phase indicator lamp colour RED/YELLOW/BLUE AC 220 Volt 50 Hz. complete all as specified and directed. Make: L&T/Legrand/C&S/ABB/Schneider.
40
-
-
Supply only Digital Ampmeter of any range, flush mounting type of size 96 mm x 96 mm (4”x4”) square dial 3 phase four wire system with selector switch complete all as specified and directed.. (Make : Legrand/Schneider/L&T/AE).
18
-
-
Supply only Digital voltmeter of range (0-500) volts, flush mounting type of size 96 mm x 96 mm (4”x4”) square dial 3 phase 4 wire system with selector switch complete all as specified and directed.
18
-
-
Supply only cast resin insulated type CT, Ratio 100/5A with capable of with standing momentary short circuit and symmetrical short circuit for 01second complete all as specified and directed.
3
-
-
Supply only cast resin insulated type CT, Ratio 160/5A with capable of withstanding momentary short circuit and symmetrical short circuit for 01 second complete all as specified and directed.
3
-
-
Supply only cast resin insulated type CT, Ratio 200/5A with capable of withstanding momentary short circuit and symmetrical short circuit for 01second complete all as specified and directed.
4
-
-
Supply only cast resin insulated type CT, Ratio 250/5A with capable of withstanding momentary short circuit and symmetrical short circuit for 01second. complete all as specified and directed.
2
-
-
Supply only cast resin insulated type CT, Ratio 300/5A with capable of withstanding momentary short circuit and symmetrical short circuit for 01second complete all as specified and directed.
2
-
-
Supply only cast resin insulated type CT, Ratio 400/5A with capable of withstanding momentary short circuit and symmetrical short circuit for 01second complete all as specified and directed.
2
-
-
Supply only copper bus bar any size (5x20, 10x20, 10x25, 10x40, 10x50,10x80) mm duly insulated with heat shrink busbar insulation sleeves complete all as specified and directed.
40
-
-
Supply only aluminium bus bar any of any size duly insulated with heat shrink busbar insulation sleeves complete all as specified and directed.
25
-
-
Supply only rubber door gasket of any size for existing door complete all as specified and directed.
50
-
-
M&L in repair for replacement of MS sheet cover of LT panel board made out of any thick MS sheet as per required shape and size including necessary fabrication,welding and two coats of synthetic enamel painting over a coats of red oxide after proper preparation of steel surface complete and fixing accessories etc to match with existing panel surface complete all as specified and directed.
80
-
-
M&L for spray painting on existing steel surface of Panel/FPB/JB etc with two coats of synthetic enamel paint including one coat of red oxide on rusted area after proper cleaning and prepration of old painted surfaces steel / Iron of any description with spray machine complete all as specified and directed.
Note:- Painting of panels / feeder filler boxes shall be carried out in different colour of paints as required at site and as directed).
160
-
-
Excavating and relaying of cables loops near the poles, panels, distribution box, cutting the damages/burnt parts of cable and reconnecting in the same position with aluminium thimbles/lugs of same size of cable, nuts bolts and washer (made of stainless steel) with proper insulation and cable sleeves etc complete all as specified and directed.
Note : (i) Cost of nuts, bolts, washer, aluminium thimble/Lugs, insulation tape shall be deemed to be included in the quoted rate. (ii) Cost of sleeves measured and paid separately on relevant items of the schedule.
45
-
-
S&F in repair of Air circuit breaker (ACB) 4 Pole, 415 V, single frame size options of drawout type manual and electrical opertaed with advanced self powered electronic protection units MP2 and MP4 and LCD display with current metering + 10 trip histroy +10 Alarms +Logical selectivity, neutral overload protection OFF-50%-100%, In built temperature protection capacity 630 Amps 50 KA fixed in existing LT panel complete all as specifed and as directed. Make: Legrand/ Siemen/ABB
Note : If any additional and alteration required to fixed the ACB in existing panel, the cost of the fabrication work shall be deemed to be included in quoted rate.
1
-
-
M&L for repair/serviceing and comprehensive maintenance of Air Circuit breaker (ACB) of make (Make: L&T/Legrand/C&S/ABB/Schneider) and any capacity by disconnecting the breaker from existing position and detecting the fault, replacement the defective parts with new one and , commossioning and testing the following :- (a) Tripping coil, spring holder. (b) Push buttom. (c) Contactor (d) Trip coil Supervision
(e) Aux switch (f) UVT Coil (g) Miss insertion preventer, (h) Control terminal protection cover (j) Mechanical interlock etc complete all as specified and directed by Engineer-in-Charge.
Note :- (i) All other Spare parts shall be measured and paid separately under relevant items.
1
-
-
Supply only shunt triping coil for ACB capacity 630 Amp any make as per sample in existing size complete all as specified and directed. Make: L&T/Legrand/C&S/ABB/Schneider.
1
-
-
Supply only shunt Closing coil for ACB capacity 630 Amp any make as per sample of existing in site complete all as specified and directed. Make: L&T/Legrand/C&S/ABB/Schneider.
1
-
-
Supply only under voltage trip device of ACB capacity 630 Amps any make as per sample of existing in site all as specified and directed. Make: L&T/Legrand/C&S/ABB/Schneider.
1
-
-
Supply only spring charge indication switch for 630 Amps for shunt Triping coil as per sample of existing in site all as specified and directed. Make: L&T/Legrand/C&S/ABB/Schneider.
1
-
-
Supply only Trip indication switch for ACB capacity 630 Amps any make complete all as specified and directed. Make: L&T/Legrand/C&S/ABB/Schneider.
1
-
-
Supply only Phase insulation Barrier as per sample of existing in site complete all as specified and directed. Make: L&T/Legrand/C&S/ABB/Schneider.
1
-
-
Supply only mechanism system as per sample of existing in site all as specified and directed. Make: L&T/Legrand/C&S/ABB/Schneider.
1
-
-
Supply only condenser Trip Device (CTD) Unit as per sample of existing in site all as specified and directed. Make: L&T/Legrand/C&S/ABB/Schneider.
1
-
-
Supply only test jumper as per sample of existing in site all as specified and directed. Make: L&T/Legrand/C&S/ABB/Schneider.
1
-
-
Supply, installation, testing and commissioning 3 phase and neutral, 415 volts outdoor type LT panel board of size 1200 mm height X 1200 mm width X 500 mm depth (over all dimension) confirming to IS 8623, CPRI approved, factory fabricated & factroy assembled , waterproof,dust and vermin proof cubical type with locking arrangement , LT Panel made out of suitable size angle iron, channel and fabricated from 3.00 mm thick (minimum) CRCA sheet with anti corrosive coating and finally epoxy polyester powder coating of flint Grey shade (RAL-7032), independently housing for each control switch gear and indicating lamps with & including busbars made of pure copper duly insulated with heat retardent fire proof (HRFR) heat shrinkable sleeves of relevant colours. Bus bar shall be properly supported/mounted on epoxy insulators.All live parts and joints shall be insulated with (HRFR) shrouds, conforming to IS, including copper strip busbar of suitable rating to MCCB input and MCCB output to cable alley of suitable length and provn for cable gland and lugs for incoming and out going cable and connecting suitable earth strips .Suitable openable doors shall be provided of all operational switchgear and MCCBs and detchable cover shall be provided on all other accessories. Grouting the panel board in ground with & including suitable size of foundation & plinth of PCC 1:3:6(type C-1 using 20 mm grade stone aggregate) complete.Panel shall be manufactured suitable for housing and including the following duly control wiring with multistranded copper condutor FRLS with colour coding incl connection with copper lugs complete for 3 phase 50 Hz electric supply with the following :- Incoming
(a) Copper strip busbar of current carrying capacity 350 Amps wrapped with PVC sleeves with maintained the colour code and provision of making holes with Copper nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends = 04 nos.
(b) MCCB 250 Amp, 4 Pole, 415 Volts, 36 KA rating with overload, short circuit fault protection 3 phase, Ics = 100% of Icu and shall have roto operative double break mechanism along total break time less than equal to 10 ms with Spreader terminal of both end side - 02 Nos. Make: Schneider Cat no - LV525343 / Legrand Cat No: 420249/ Siemens, Cat: 3VA1225-4GE42-0AA0/ ABB, Cat No: 1SDA068111R1.
(c) On load change over switch front handle open execution capcity 250 Amp 4 pole 415 volt AC 50 HZ suitable for horizontal and verticle mounting including terminal shrouds, source separator, phase barrier - 01 Nos (Make L&T, Siemen, ABB)
(d) Digital voltmeter of range (0-500) volts, flush mounting type of size 100mm x 100mm (4”x4”) square dial with selector switch – 01 Nos (Make : Legrand/Schneider/siemeL&T).
(e) Digital Ammeter flush mounting type of size 100mm x 100mm (4”x4”) square dial with CT’s of ratio 100/5 and selector switch – 01 set. Make- Legrand/Schneider/Siemens/L&T.
(f) LED Neon indicator lamp (RYB) with holder,230/250 volts,AC - 01 set (set of three) Make : Legrand/Schneider/L&T. Out going:-
(a) MCCB 100 Amp, 4 Pole, 415 Volts, 25 KA rating with overload, short circuit fault protection 3 phase, Ics = 100% of Icu and shall have roto operative double break mechanism along total break time less than equal to 10 ms with Spreader terminal of both end side - 03 Nos. Make: Schneider Cat no - LV510317 / Legrand Cat No: 420055/ Siemens, Cat: 3VA1110-3GE42-0AA0/ ABB, Cat No: 1SDA067406R1.
(b) MCB TPN 40 Amp, 230 volts 10 KA 'C' Curve, - 04 Nos Make : Siemens/Legrand /Schnieder/ABB.
(c) MCB DP 32 Amp 230 volts 'C' curve -03 Nos Make : Siemens/Legrand /Schnieder/ABB.
1
-
-
Supply, installation, testing and commissioning 3 phase and neutral, 415 volts outdoor type LT panel board of size 1000 mm height X 700 mm width X 500 mm depth (over all dimension) confirming to IS 8623, CPRI approved, factory fabricated & factroy assembled , waterproof,dust and vermin proof cubical type with locking arrangement , LT Panel made out of suitable size angle iron, channel and fabricated from 3.00 mm thick (minimum) CRCA sheet with anti corrosive coating and finally epoxy polyester powder coating of flint Grey shade (RAL-7032), independently housing for each control switch gear and indicating lamps with & including busbars made of pure copper duly insulated with heat retardent fire proof (HRFR) heat shrinkable sleeves of relevant colours. Bus bar shell be properly supported/mounted on epoxy insulators.All live parts and joints shall be insulated with (HRFR) shrouds, conforming to IS, including including copper strip busbar of suitable rating to MCCB input and MCCB output to cable alley of suitable length and provn for cable gland and lugs for incoming and out going cable and connecting suitable earth strips .Suitable openable doors shall be provided of all operational switchgear and MCCBs and detchable cover shall be provided on all other accessories. Grouting the panel board in ground with & including suitable size of foundation & plinth of PCC 1:3:6(type C-1 using 20 mm grade stone aggregate) complete.Panel shall be manufactured suitable for housing and including the following duly control wiring with multistranded copper condutor FRLS with colour coding incl connection with copper lugs complete for 3 phase 50 Hz electric supply with the followings :- Incoming:- (a) Copper strip busbar of current carrying capacity 200 Amps wrapped with PVC sleeves with maintained the colour code and provision of making holes with Copper nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends = 04 nos.
(b) MCCB 160 Amp, 4 Pole, 415 Volts, 25 KA rating with overload, short circuit fault protection 3 phase, Ics = 100% of Icu and shall have roto operative double break mechanism along total break time less than equal to 10 ms with Spreader terminal of both end side - 01 Nos. Make: Schneider Cat no - LV516313 / Legrand Cat No: 420057/ Siemens, Cat: 3VA1116-3GE42-0AA0/ ABB, Cat No: 1SDA067410R1.
(c) Digital voltmeter of range (0-500) volts, flush mounting type of size 100mm x 100mm (4”x4”) square dial with selector switch – 01 Nos (Make : Legrand/Schneider/siemeL&T).
(d) Digital Ammeter flush mounting type of size 100mm x 100mm (4”x4”) square dial with CT’s of ratio 100/5 and selector switch – 01 set. Make- Legrand/Schneider/Siemens/L&T.
(e) LED Neon indicator lamp (RYB) with holder,230/250 volts,AC - 01 set (set of three) Make : Legrand/Schneider/L&T.
Out going:- (a) MCCB 63 Amp, 4 Pole, 415 Volts, 25 KA rating with overload, short circuit fault protection 3 phase, Ics = 100% of Icu and shall have roto operative double break mechanism along total break time less than equal to 10 ms with Spreader terminal of both end side - 02 Nos. Make: Schneider Cat no - LV510315 / Legrand Cat No: 420053/ Siemens, Cat: 3VA1163-3GE42-0AA0/ ABB, Cat No: 1SDA067404R1.
(b) MCB TPN 40 Amp, 230 volts 10 KA 'C' Curve, - 04 Nos Make : Siemens/Legrand /Schnieder/ABB.
(c) MCB DP 32 Amp 230 volts 'C' curve -03 Nos Make : Siemens/Legrand /Schnieder/ABB.
(d) MCB TPN 40 Amp C curve -04
3
-
-
Supply ,fabrication, installation and testing of LT out door type factory made CPRI Approved , junction box of size 900mmX600mmX400mm (over all dimension) made out of 3.15 mm thick CRCA sheet dully supported with mild steel angle iron of size 40X40X5mm vertical frame and legs with mild steel flat iron 25X5 mm in horizontal sides of the frame with front and back side openable ,single hinged door / shutter with locking arrengement and powder coated finish both internal and external steel surfaces after necessary preparation of steel surfaces including providing PCC (1:3:6) type C2 foundation of size 0.80m X 0.6m X 0.90m depth (0.30m below ground level and 0.60m above ground level ) and connections of all outgoing / incomming existing cable of any size drawing / digging out cable from loops in trenches inclusive of necessary excavation and earthwork as required and relaying the cables including the following fitment accessories all complete as specified and as directed.
(a) Alluminium bus bar of size 50 mm X 6 mm X 400mm long wrapped with PVC sleeves with maintained the colour code and provision of making holes as required with nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends = 04 nos.
(b) Enamelled iron danger notice plate of 1.60 mm thick mild steel sheet of size 200 mm X 150mm , white with letters , figures and conventional skull and bones in signal red and fixed with nuts and bolts on door / shutter of JB for LT -01 No.
2
-
-
S& F in repair of copper spreader terminal Kit suitable for MCCB capacity 63 to100 Amp of any make and as per existing MCCB at site complete all as specified and directed.
60
-
-
S& F in repair of copper spreader terminal Kit suitable for MCCB capacity 125- 200 Amp of any make and as per existing MCCB at site complete all as specified and directed.
40
-
-
S& F in repair of copper spreader terminal Kit suitable for MCCB capacity 200 to 320 Amp of any make and as per existing MCCB at site complete all as specified and directed.
30
-
-
S& F in repair of copper spreader terminal Kit suitable for MCCB capacity 400 Amp of any make and as per existing MCCB at site complete all as specified and directed.
20
-
-
M&L for Painting of steel pole with cross arms, clamp of any length and shape for LT overhead line with single coat of aluminium paint including preparation of the existing surface including marking pole numbers in a 20 cm dia black circle with white letter painting of 3 Nos black & 02 Nos yellow bands width 30 cm by fluorescent paint in alternate layers upto 1.5 mtr height above the P.C.C coping and two coat of aluminium paint beyond 1.5 meter height complete all as specified and directed.
180
-
-
M&L for painting of 9 m PCC pole with cement wash two coat by using the cement and two coat of aluminium paint over cross arms, clamp of any length and shape for LT overhead line including preparation of the existing surface including marking pole numbers in a 15 cm dia Black circle & marking three black & two yellow bends width 30 cm by fluorescent paint, from bottom of pole to 1.5 Mtr height complete all as specified and directed.
20
-
-
M&L in repair LT line PVC Spacers spiral type for two wire complete all as specifed and as directed.
15
-
-
M&L in repair LT line PVC Spacers spiral type for three wire complete all as specifed and as directed.
10
-
-
M&L in repair LT line PVC Spacers spiral type for four wire complete all as specifed and as directed.
10
-
-
M&L in repair LT line PVC Spacers spiral type for five wire complete all as specifed and as directed.
10
-
-
Relaying of old serviceable brick as in cable protection complete all as specified and directed.
2820
-
-
Taking out old unserviceable under ground cable of any size and any position from trenches, floors and wall and segrate the serviceable portion cable for reuse complete all as specified and directed.
1500
-
-
Labour for drilling hole under the road with the help of bocki / by manual or by machine for crossing GI tubing of any size 100 mm pipe for cable protection complete all as specified and directed.
40
-
-
Relaying of serviceable cable of any size retrieved here-in-above item after detecting the fault and making straight through jointing kit of 1100 volt grade complete all as specified and directed.
Note:-Necessary excavation,returning filling, removal of soil and straight through joint shall be measured and paid separately under respective item of this schedule.
550
-
-
M & L for PCC earth pit chamber of internal dimension (300x300x300) mm and having wall thickness 100 mm using PCC 1:2:4 type B1 alongwith RCC 1:2:4 type B1 precast cover 50 mm thick reinforced with 8 mm TMT bars both way @100mm c/c including one lifting handle and dismantling of old one complete all as specified and directed.
16
-
-
Supply,laying & fixing double wall corrugated (DWC) pipes of size 63 mm outer dia and 50mm inner dia made of high density polythyline (HDPE) conforming to IS 16205 (Part-24) in place of old Bricks including all accessories i.e. all type of joints, Sockets, Elbows, bends and End caps etc.. complete all as specified and directed.
280
-
-
Supply and fixing cable jointing kit for 1.1 KV grade cable for straight through joint complete with jointing material heat shrink type and accessories suitable for 3½ core XLPE, armoured, Aluminium conductor cable of size 240 to 300 sqmm complete all as specified and as directed.
2
-
-
Supply and fixing cable jointing kit for 1.1 KV grade cable for straight through joint complete with jointing material heat shrink type and accessories suitable for 3½ core XLPE, armoured, Aluminium conductor cable of size 150 to 185 sqmm complete all as specified and as directed.
4
-
-
Supply and fixing cable jointing kit for 1.1 KV grade cable for straight through joint complete with jointing material heat shrink type and accessories suitable for 3½ core XLPE, armoured, Aluminium conductor cable of size 70 to 120sqmm complete all as specified and as directed.
8
-
-
Supply and fixing cable jointing kit for 1.1 KV grade cable for straight through joint complete with jointing material heat shrink type and accessories suitable for 3½ core XLPE, armoured, Aluminium conductor cable of size 25 to 50 sqmm complete all as specified and as directed.
10
-
-
Supply and fixing cable jointing kit for 1.1 KV grade cable for straight through joint complete with jointing material heat shrink type and accessories suitable for 4 core XLPE, armoured, Aluminium conductor cable of size 6 to 16 sqmm complete all as specified and as directed.
10
-
-
Supply and fixing cable jointing kit for 1.1 KV grade cable for straight through joint complete with jointing material heat shrink type and accessories suitable for 2 core XLPE, armoured, Aluminium conductor cable of size 6 to 16 sqmm complete all as specified and as directed.
8
-
-
S & F LT heat shrinkable type indoor/outdoor end termination cable jointing kit with jointing material and accessories suitable for 1100 volt (Earthed) grade 3½ core XLPE, armoured, Al conductor cable of size 240 to 300 sqmm,complete all as specified and directed.
2
-
-
S & F LT heat shrinkable type indoor/outdoor end termination cable jointing kit with jointing material and accessories suitable for 1100 volt (Earthed) grade 3½ core XLPE, armoured, Al conductor cable of size 150 to 185sqmm,complete all as specified and directed.
8
-
-
S & F LT heat shrinkable type indoor/outdoor end termination cable jointing kit with jointing material and accessories suitable for 1100 volt (Earthed) grade 3½ core XLPE, armoured, Al conductor cable of size 70 to 120 sqmm,complete all as specified and directed.
7
-
-
S & F LT heat shrinkable type indoor/outdoor end termination cable jointing kit with jointing material and accessories suitable for 1100 volt (Earthed) grade 3½ core XLPE, armoured, Al conductor cable of size 25 to 50 sqmm,complete all as specified and directed.
12
-
-
Supply and fixing LT cable sleeves with colour coding (Red, Yellow, Blue and Black ) suitable for 1100 volt grade 3 ½/4 core XLPE, armoured, aluminium conductor of cable size 10 sqmm to 25 sqmm all as specified and directed.
300
-
-
Supply and fixing LT cable sleeves with colour coding (Red, Yellow, Blue and Black ) suitable for 1100 volt grade 3 ½/4 core XLPE, armoured, aluminium conductor of cable size 35 sqmm to 50 sqmm all as specified and directed.
130
-
-
Supply and fixing LT cable sleeves with colour coding (Red, Yellow, Blue and Black ) suitable for 1100 volt grade 3 ½/4 core XLPE, armoured, aluminium conductor of cable size 70 sqmm to 95 sqmm all as specified and directed.
120
-
-
(Note : The Scope of Work contained in 'Sch of Credit' amounting to Rs. 1,44,940.00 (refer Tender Srl Page No 33). The Quoted sum shall be arrived at after deducting the amount of “Sch of Credit” from the total amount of the ‘BoQ’
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements