Military Engineer Services Tender
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.
Military Engineer Services - MES Tender
Civil And Construction
Civil Works Others
Electrical and Electronics
Electrical Works
Eprocure
Opening Date13 Nov 2024
Closing Soon3 Dec 2024
Tender Amount₹ 29,50,000
Costs
EMD
₹ 59,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_683793_1Tender No
8323/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
REPAIR MAINT OF AREA LIGHTING, STREET LIGHT POLES, JUNCTION BOXES, ASTRONOMICAL TIMER AND OTHER CONNECTED ITEMS AND CERTAIN AREAS LIKE MES IB, COMD OFFR MESS, KITCHENER HOUSE, CHOWRANGHE AND WATER GATE HOUSE, RAMPARTS AT INSIDE FW UNDER GE FW KOLKATA
REPAIR MAINT OF AREA LIGHTING, STREET LIGHT POLES, JUNCTION BOXES, ASTRONOMICAL TIMER AND OTHER CONNECTED ITEMS AND CERTAIN AREAS LIKE MES IB, COMD OFFR MESS, KITCHENER HOUSE, CHOWRANGHE AND WATER GATE HOUSE, RAMPARTS AT INSIDE FW UNDER GE FW KOLKATA
BOQ Items
Removal of surplus soil to a distance not exc. 50m and deposited where directed at a level not exc. 1.5 m above the starting point all as specified and as directed.
32.7
-
-
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick each, excavated soil in trenches after the cables have been laid and tested complete all as specified and directed by Engineer-in-Charge
294.3
-
-
M&L for Brick protection with subclass ‘B’ bricks old size, laid dry, flat over cable perpendicular across the cable in trenches complete all as specified.
4500
-
-
Laying Only Serviceable Bricks after cleaning by wire brush obtained from taking out unserviceable LT cable in connected items here-in-after.
4000
-
-
Taking out of interlocking paver block, any shape or size and Re-laying the same after removing all vegetation, algae, grass etc, laid to proper slope & gradient over sand cushioning complete all as specified and directed.
(NOTE: Sand, if required for correction of cushioning level will be measured and paid separately. Replacement of broken paver block shall be paid separately as "Supply only")
50
-
-
Material and labour for machine pressed precast concrete interlocking paver block with grey cement and pigment of any shape and size as approved by GE conforming to IS 15658-2006 of 60 mm thickness, M-35 grade complete all as specified and directed.
50
-
-
Taking down unserviceable LT cable for repair/ replacement etc (from cable duct/underground trench / pole), stacking properly (cable, pipe and bricks) complete all as directed by the Engr-in-Charge of the following cross - sections :- (Note :- Necessary earth work to be measured and paid separately.
-
-
-
10 sqmm 4 core to 16 Sqmm, 4 Core
900
-
-
25 Sqmm to 35 Sqmm, 3.5 core
900
-
-
Relaying of XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured electric power cable 1100 Volts grade with stranded aluminium conductor cable, laid in trench or fixed to wall / passing through pipe/ pole. (retrieved against item No 1 above) incl necessary aluminium thimbles, jointing and testing complete all as specified and directed for the following sizes and cross sectional area :- (Note :- Necessary earth work to be measured and paid separately.
-
-
-
10 sqmm 4 core to 16 Sqmm, 4 Core
300
-
-
25 Sqmm to 35 Sqmm, 3.5 core
300
-
-
Supply, Laying, jointing and testing XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured electric power cable 1100 Volts grade with stranded aluminium conductor cable, laid in trench or fixed to wall/passing through pipe/pole incl necessary thimbles complete all as specified and directed for the following sizes and cross sectional area :- (Note :- Necessary earth work to be measured and paid separately.
-
-
-
10 Sqmm, 4 core
300
-
-
16 Sqmm, 4 core
300
-
-
25 Sqmm, 4 core
300
-
-
35 Sqmm, 3.5 core
300
-
-
Taking out existing unserviceable/ defective light fitting / high bay light fitting of any wattage from poles/walls/ high mast (including taking down of high mast fitting), dismantling the complete fittings of checking out the defects, trace out damage/ unserviceable parts like driver, wire, led lamp etc and clean thoroughly the complete set and re-fixing in its original position after replacing defective parts including testing complete all as specified and as directed by Engr-in-Charge. Note :- (a) Any minor item like nuts, bolts, clamps, washers and wires for connection is required to make the fitting serviceable are deemed to be included in the quoted rate. (b) Defective parts replaced against relevant items shall be paid under supply only item.
145
-
-
M&L for replacement of electronic driver with input voltage 220 to 240 volts and output voltage suitable for different LED of luminaires, complete all as specified and directed for the following types and capacities:-. (NOTE: Make of driver shall be as OEM or any other make as specifically approved by GE)
-
-
-
35 to 120 watt street light luminaire
60
-
-
50 to 250 watt street light luminaire
30
-
-
8 to 20 watt bollard
25
-
-
Supply and fixing in repair of Glow sign board of electrical driver including LED of 2W to 10W with input voltage 220 to 240 volts and output voltage suitable for different LED of luminaires, complete all as specified and directed for the following types and capacities:-. (NOTE: Make of driver shall be as OEM or any other make as specifically approved by GE)
6
-
-
Material and labour for brick work with locally available sub class ‘B’ old size best quality bricks straight or curved on plan exc 6 m mean radius built in cement mortar (1:4) all as specified and directed.
2
-
-
M&L for replacement of Pole Mounted Junction Box 254 x 180 x 111mm, having insulated and made out of thermoplastic Polycarbonate with glass fibre reinforced, rated for Degree of Ingress Protection IP 66 in accordance with IEC 60529, IK 07, weather proof for outdoor installation (with knockouts for cable entry) having Gasket Material shall be Polyurethane and the Gasket shall be internally embedded, Tested at 650°C, with Plastic Mounting Bracket, Din Rail, Mild Steel Flat Iron Clamp, Nuts, Bolts and Washers, with MCB SP 6 Amps, 'B' Curve, 10 KA, complete all as specified and as directed. MAKE: CAPE Electric Model No. TKPS 2518 - 11M or HENSAL cat Pt No. KF 2525B or equivalent SPELSBERG/RITTAL/SCHNEIDER
30
-
-
S&F in replacement of PVC insulated multistranded copper conductor wire, 1.5 Sqmm 3 Core, round flexible for connection of light fittings, complete all as specified and as directed.
500
-
-
Material and labour for 15 mm thick rendering in cement mortar (1:4) on other than fair face of brick or concrete surface finished even and fair all as specified and directed.
30
-
-
S&F in repairs LED Street Light fitting, of various capacity as mentioned under, in high pressure die cast aluminium housing with prismatic polycarbonate modular secondary lens optics with integrated constant current electronic driver, top opening driver cover, IP66 ingress protection, impact resistance of IK07 complete all as specified and directed and complying with the following specifications:-.
(a) minimum system efficacy 120 lumen/watt
(b) CRI not less than 70, (c) THD 10%
(d) Power Factor not less than 0.90
(e) having in built short circuit and surge protection upto 4 kV
(f) having 10 KV external surge protection (for 45 watt & above)
(g) colour temperature not less than 5700 degree K
(h) life not less than 50000 hours of operation
-
-
-
All as per Item No 20 above but 72 Watt Street Light Luminaire ( SURYA CAT NO- SLE UL 72 IP66 LXN/ HAVELLS CAT NO- ENDURASUNDOWNSL72WLED765PASYBOTG / Philips CAT NO- BRPO32 P LED75 CW SLR,PSU GR SPD or equivalent modal in other Makes specified in the tender)
30
-
-
All as per Item No 20 above but 90 Watt Street Light Luminaire ( SURYA CAT NO- SLE UL 90W IP66 LXN/ HAVELLS CAT NO- ENDURASUNDOWNSL90WLED765PASYBOTG / PHILIPS CAT NO- BRPO33 P LED90 CW SLR,PSU GR SPD or equivalent modal in other Makes specified in the tender
30
-
-
All as per Item No 20 above but 120 Watt Street Light Luminaire ( SURYA CAT NO- SLE UL 120W IP66 LXN/ HAVELLS CAT NO- ENDURASUNDOWNSL120 WLED765PASYBOTG / PHILIPS CAT NO- BRPO33 P LED120 CW SLR,PSU GR SPD or equivalent modal in other Makes specified in the tender
30
-
-
S&F in repairs LED Flood Light fitting, of various capacity as mentioned under, in high pressure die cast aluminium housing with prismatic polycarbonate modular secondary lens optics with integrated constant current electronic driver and toughened glass cover, IP66 grade ingress protection, impact resistance IK07 complete all as specified and directed and complying with the following specifications:-.
(a) minimum system efficacy 120 lumen/watt
(b) CRI not less than 70, (c) THD 10%
(d) Power factor not less than 0.90
(e) having in built short circuit and surge protection upto 4 kV
(f) having 10 KV external surge protection (g) colour temperature not less than 5700 degree K
(h) life not less than 50000 hours of operation
-
-
-
All as per Item No 21 above but 70 Watt Flood Light Luminaire (PHILIPS CAT NO- BVP1281 LED085 CW FG SY5WB 70W V1 / SURYA CAT NO- SLE FL 70W IP66 LMS NEO N/ HAVELLS CAT NO-JETAALBAFLOODLIGHT70W or equivalent modal in other Makes specified in the tender
15
-
-
All as per Item No 21 above but 120 Watt Flood Light Luminaire (HAVELLS CAT NO-JETAIRISFL120W LED757APWBLTG/ SURYA CAT NO-SLE FL 120W IP66 LMS NEO N/CGL CAT NO- TFS-504-70-57-60D-HL2-GL-NSG or equivalent modal in other Makes specified in the tender
15
-
-
All as per Item No 21 above but150 Watt Flood Light Luminaire( SURYA CAT NO- SLE FL 150W IP66 LMS NEO N / HAVELLS CAT NO- JETAIRISFLS150WLED757PWBLTG/PHILIPS CAT NO- BUP283LED181CW FG SY5NB 150W V1 or equivalent modal in other Makes specified in the tender
15
-
-
S&F in repairs LED Highbay luminaire 200 Watt (with system lumen efficacy 130 lumen /watt), circular shape, of various capacity as mentioned under, in high pressure die cast aluminium/LM6 alloy housing with secondary modular lens optics and toughened glass cover with integrated constant current electronic driver, IP66 ingress protection complete all as specified and directed and complying with the following specifications:-.
(a) minimum system efficacy 130 lumen/watt (b) CRI not less than 80, (c) THD 10%
(d) Power factor not less than 0.90
(e) having in built short circuit and surge protection upto 5 kV
(f) colour temperature not less than 5700 degree K
(g) life not less than 50000 hours of operation (SURYA CAT NO- SLE HB 200W COMET NEO-N/ CGL CAT NO- FFL 1315-200-CDL/60-HB-M/ HAVELLS CAT NO- SAUCERGENXADVHBP200WLED757PWBBORL)
6
-
-
S&F LED Bollard light 8W to10W,Oval/Mushroom type luminaire with soft 360 degree light distribution, with IP 65 grade protection, operating voltage 120-280V, with integrated constant current electronic driver incl all fittings and fixtures complete with PCC work incl taking down existing luminaire complete all as specified and directed. (Make :CGL CAT NO- LBLSR 10-WW/HAVELLS CAT NO-CONENX4BL8WLED PSYM857TOPCM/ SURYA CAT NO- SLE BL 10W-FLR650 NX or equivalent modal in other Makes specified in the tender)
20
-
-
S&F LED Bollard light 9W, inverted pyramid tripod type luminaire with soft 360 degree light distribution, with IP 65 grade protection, operating voltage 120-280V, with integrated constant current electronic driver incl all fittings and fixtures complete with PCC work incl taking down existing luminaire complete all as specified and directed. (Make :CGL CAT NO- LBLSR 10-WW/PHILIPS CAT NO-BCP400LED09DCW PSU GR S1/ SURYA CAT NO- SLE BL 9W-BLK800 or equivalent modal in other Makes specified in the tender)
15
-
-
S&F LED post top luminaire, 30-35 watt, with die cast aluminium spigot, spun aluminium powder lantern type coated top cover, with high power LED, IP 65 grade protection, designed with indirect symmetrical light distribution, with integrated constant current electronic driver incl taking down existing luminaire complete all as specified an directed.
(Make : SURYA, CAT NO: SLE PT 30W-ETPP / HAVELLS-CORALPT 35WLED830PSYMTOPC/ PHILIPS CAT NO-BGP200 LED35 CW PSU GR CPC SPD or equivalent model in other makes specified in particular specifications)
NOTE: Wire for connection of luminaire shall be measured and paid separately.
15
-
-
S&F LED post top luminaire, 20-30 Watt, with die cast aluminium spigot, spun aluminium powder ,heritage type coated top cover, with high power LED, IP 65 grade protection, designed with indirect symmetrical light distribution, with integrated constant current electronic driver incl taking down existing luminaire complete all as specified and directed.
(Make : SURYA, CAT NO: SLE PT 30W-HARY / CGL-LPTH-20-WW/ JAGUAR CAT NO-LGTP02X030XW or equivalent model in other makes specified in particular specifications)
NOTE: Wire for connection of luminaire shall be measured and paid separately.
120
-
-
M&L for replacement of GI Pipe Bracket made out of Galvanised Iron Tubing 32/40mm bore (dia), light grade, 1.50 Metre long fixed with 02 sets of flat iron clamp of size 25mm x 5 mm, with bolts, nuts and washers of suitable size including applying two coats of aluminium paint over a coat of red oxide zinc chrome primer incl taking down existing bracket complete all as specified and as directed by the Engr-in-Charge.
30
-
-
M&L for replacement of Galvanised Steel Tubing Pipe 40mm bore (dia), light grade, length 0.60 mtr having 50 Cm with long Bends, Each for Incoming and Outgoing Cables, grouting in Cement Concrete, complete all as specified and as directed.
NOTE : Cement Concrete will be measured and paid for separately under appropriate Item.
50
-
-
Dismantling of broken/dislodged pre-stressed concrete poles / steel tubular poles, of any description including earthwork for removal of concrete foundation, keeping serviceable poles in safe custody for re-use and removal of unserviceable poles from site, complete all as specified and directed.
15
-
-
Supply and fix Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws fixed with MS clamp 40 x 6 mm and 2 set with nut & bolt as specified type 410 SP-31 (9 Meter long) duly painting with two coats of aluminium paint over a coat of red oxide primer on exposed surface and one coat of black bituminous paint on embedded surface incl writing of Pole Numbers etc., and marking of two black & two yellow strips with synthetic enamel paint upto 1.2 Mtr height and making good disturbed surface complete all as specified and directed.
10
-
-
Erecting of serviceable pre-stressed concrete poles/steel tubular poles (Serviceable steel tubular pole/pre-stressed concrete poles obtained from Item No. 29.00 here-in-before), of any description, with cast iron base plate, finial taper plug, bolts, nuts & screws fixed with MS clamp 40 x 6 mm and 2 set with nut & bolt etc, including demolition of existing PCC foundation and making good disturbed surfaces complete all as specified and directed.
(NOTE: PCC foundation for installation of pole shall be measured separately)
5
-
-
S&F Astronomical time switch with USB key 2 module 240 Volt AC, DIN mounting type suitable for street light operation, as in repairs, complete all as specified and directed.
(MAKE: LEGRAND / SCHNEIDER / INDO ASIAN/C&S
6
-
-
S&F Contractor 40 Amps, 3mdule 2 NO+2NC, type1, DIN mounting type suitable for street light operation, as in repairs, complete all as specified and directed.
(MAKE: LEGRAND / SCHNEIDER / INDO ASIAN/C&S
4
-
-
S&F MCB TPN 63 Amps, 415 Volts, 10 kA, 'C' curve, as in repairs, complete all as specified and directed.
(MAKE: L&T, Cat No: BB40630C or equivalent model in LEGRAND / HAGER / SCHNEIDER / INDO ASIAN)
3
-
-
S&F LED flex strip light 5 watt , 45m to 50m length, IP 65, 5watt/metre, any colour including suitable driver and connecting up with three core flexible copper conductor cable of suitable size, as in repairs, complete all as specified and directed.
(MAKE : SURYA Cat No SPARKLE ROPE LIGHT/ PHILIPS CAT NO-MARATHON ULTRA YELLOW ROPE LIGHT/WIPRO CAT NO- GARNET 50 MTR LED STRIP LIGHT or equivalent model in other makes specified in tender)
10
-
-
S&F LED Rope light Tri colours in same length of (Orange+ White+ Green) of 6m length each. IP 65,), including suitable driver and connecting up with three core flexible copper conductor cable of suitable size, as in repairs, complete all as specified and directed.
(MAKE : SURYA Cat No SPARKLE ROPE LIGHT/ PHILIPS CAT NO- TRICO AC LED STRIP LHEHCIPIN6F135/ WIPRO CAT NO- GARNET 18 MTR TRICOLOUR LED STRIP LIGHT or equivalent model in other makes specified in tender)
40
-
-
S&F LED statue focus light in die cast aluminium housing with high quality toughened glass diffuser IP 65,), including suitable connecting up with three core flexible copper conductor cable of suitable size, as in repairs, complete all as specified and directed.
(MAKE : SURYA Cat No SLE BSL 9W MALLOW/ HAVELLS CAT NO- LYCUS LED SPIKE LIGHT LYCUSSP S9W LED 730PSYMBOTG/ JAGUAR CAT NO- LSPK0 5R112SW or equivalent model in other makes specified in tender)
6
-
-
S&F LED Up down wall light in die cast aluminium housing with high quality toughened glass cover IP 65,), including suitable connecting up with three core flexible copper conductor cable of suitable size, as in repairs, complete all as specified and directed.
(MAKE : SURYA Cat No SLE WL15W UP-DOWN / HAVELLS CAT NO-C LYCUS LED SPIKE LIGHT LYCUSSP S9W LED 730PSYMLIOWLS15WLED830PSYMTOTG/ JAGUAR CAT NO- 460LL9X2H.NHG or equivalent model in other makes specified in tender)
15
-
-
S&F LED Bulk head light in die cast aluminium housing with high quality toughened glass cover IP 65,), including suitable connecting up with three core flexible copper conductor cable of suitable size, as in repairs, complete all as specified and directed.
(MAKE : MAGIK Cat No HWARO12W /PHILIPS CAT NO-VISTA GLOW-WT 110/ CGL CAT NO- CIS-306-10-57-SL-DP-NBK or equivalent model in other makes specified in tender)
6
-
-
S&F LED 2 head out door wall lights in die cast aluminium housing with high quality toughened up and down of 4Wglass cover IP 65,), including suitable connecting up with three core flexible copper conductor cable of suitable size, as in repairs, complete all as specified and directed.
(MAKE : PHILIPS CAT NO- GAMMA 2HEAD WALL LIGHTMODEL NO 581934 or equivalent model in other makes specified in tender)
6
-
-
S&F LED 3 head out door wall lights in die cast aluminium housing with high quality toughened up down of 7W glass cover IP 65,), including suitable connecting up with three core flexible copper conductor cable of suitable size, as in repairs, complete all as specified and directed.
(MAKE : PHILIPS CAT NO- GAMMA 3HEAD WALL LIGHTMODEL NO 581935or equivalent model in other makes specified in tender)
4
-
-
S&F LED Triangular wall washer out door wall lights in die cast aluminium housing with high quality toughened of 9W glass cover IP 65,), including suitable connecting up with three core flexible copper conductor cable of suitable size, as in repairs, complete all as specified and directed.
(MAKE : PHILIPS CAT NO- GAMMA 3HEAD WALL LIGHTMODEL NO 581937or equivalent model in other makes specified in tender)
6
-
-
M&L for preparation of old painted surfaces of steel tubular poles above PCC coping including cross arms, brackets, pole box and applying one coat of aluminium paint including cleaning of wild vegetation growth/ trimming of tree branches in the vicinity, writing of poles number with sentensile measure white Paint in Black base on steel tubular pole and two black and two yellow strip upto 1.20 metre height with synthetic enamel paint complete all as specified and directed.
400
-
-
Demolition of broken/damaged PCC coping of steel tubular/PCC pole and removal of debris from site complete all as specified and directed.
4
-
-
Material and labour for PCC (1:4:8) type D-2 using 40 mm graded crushed stone aggregate as in foundations of poles, as mass concrete, complete all as specified and directed.
4
-
-
Material and labour for PCC (1:3:6) type C-2 using 20 mm graded crushed stone aggregate as in plinth cources, string cources, etc., complete including slightly rounded or chamfered for GI tubing post for ait termination rod etc., including using necessary formwork and finishing the exposed surfaces even and smooth without using extra cement complete all as specified and directed.
3
-
-
Dismantling carefully serviceable isolating LT Panel board of sizes 500mm x 500mm x 500mm to 1800mm x 2000mm x 600mm, duly unscrewing/ opening front and back cover and cleaning complete bus bar chamber, tightening all the nuts, bolts incoming and outgoing terminals including cleaning the all switchgear/ accessories and replacement of cable gland and replacement of stainless steel hinges of size 100mm for panel board door fixed with welding machine incl applying one coat of synthetic enamel paint externally to panel board ater scrubbing/ cleaning the surface complete testing the Panel board till satisfaction of Engr-in-Charge, complete all as specified and directed. Note: -
(i) Cost of necessary nuts, bolts, washers, screws and colour tape for bus bar, recharging and testing complete shall be deemed to be included in the unit quoted rate.
(ii) Quantity of stainless steel hinges as per site reqmt shall be deemed to be included in the quoted rate.
25
-
-
Material and labour for PCC (1:2:4) type B-1 using 20 mm graded crushed stone aggregate as in coping of poles / pipes / strip alignment etc using necessary formwork and finishing the exposed surfaces even and smooth without using extra cement complete all as specified and directed.
4
-
-
Note: Schedule of credit (SCHEDULE OF CREDIT) amount of Rs ________ mentioned on Page No ____ shall be deducted from the total quoted amount of BOQ.
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%