Military Engineer Services Tender
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date23 Dec 2024
Closing DateCancelled
Tender Amount₹ 33,50,000
Costs
EMD
₹ 67,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_686792_2Tender No
8701/66/2024-2025/05/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Transformer 11/0.415 kV of capacity 200 KVA. Make of Transformer - Volt Amp
4
-
-
... More
Supply & filling only Transformer Oil for topping up the level( after necessry disconnection and earthing both winding) with grade as per IS : 335 complete incl opening the tank cover and refixing the same and charging the transformer to the supply voltage complete all as specified and as directed including taking out old one. Note : Die electric strength of the oil shall be ensured not less than 60 KV before filling.
1700
-
-
... More
Supply only silica gel breather including initial fiiling with required quantity of silica gel for transformers of 200 and 400 KVA capacities all as specified and as directed.
Make: Jaipuria Brothers Electrical Pvt Ltd or equivalent in other approved make.
2
-
-
... More
Supply only procelain transformer bushing with bushing rod (studs) made out of brass/ gun metal with threading and of suitable length /size as per existing including metal rings, bolts, washers, rubber rings, etc for LT secondary side of existing 11/0.433 kV step down transformer of capacity 315 KVA and 400 KVA complete all as specified and as directed.
6
-
-
... More
Supply only in replacement of Oil temperature guage ranging from 0 to 150 degree C suitable for existing 11/0.433 kV step down transformer of capacity 200 KVA and 400 KVA complete all as specified and as directed.
3
-
-
... More
Supply only best quality good oil resistant gasket sheet suitable for oil cooled transformer as per IS: 4253 including cutting to shape as per existing size of transformer top covers and side covers all as specified and as directed.
5
-
-
... More
Material and labour for dismantling, lowering lifting of transformer and transporting it to worshop for rewinding work and taking back to the site after rewinding and resinstalling the transformer complete all as specified and directed by the Engr -in- charge.
1
-
-
... More
Material and labour for rewinding of existing step down 11/.433 KV transformer HT / LT coil of capacity 200/400 KVA using super enamelled copper wire of suitable guage and specifications including super enamelled iron core as per existing guage and specifications, including heating up, drying, varnishing, re-insulating with insulation of necessary class complete all as specified and directed by the Engr -in- charge.
30
-
-
... More
Material for painting of transformers with two coats of synthetic enamel paint of approved colour and writing MES No with Capital letters after removing of old paints by paint removing chemicals and mild scrapping for transformers of 315 and 400 KVA capacities all as specified and as directed.
2
-
-
... More
Maintenance of Vaccum circuit Breaker, make: PASCAL, 6.0 KV Grade, 200 to 630 Amps by licensed electrician including the following:-
(a) Switiching off VCB and conforming that supply to incomming end is properly disconnecte.
(b) Opening covers of the VCB and visual checking of epoxy housing and all parts for rust and wear.
(c) Cleaning all parts of breaker compartment with appropriate chemical to remove dust and dirt and wipping of the envelop of the vacuum interrupeter and insulating material with a clean and dry cloths.
(d) Lubricating of rotary sections and moving parts, sliding surfaces, pins, coupling section etc by applying a small amount of grease/ petrolium jelly/ machine oil as applicable.
(e) Checking of PTs, CTs control circuits, closing and tripping coil and all other parts.
(f) Replacement of detective or less reliable parts from OEM (to be measured and paid separately).
(g) Cheaking auxilliary supply and control voltage, control circuits and tightening of all conections. Note : 1. After servicing of VCB, Health check up reports will be submitted.
3
-
-
... More
Repair/ maintenance of HT Oil Isolating switch(VLE) unit of 200 Amps capacity, 3 phase manually operated fixed/draw out ID type oil isolating switch 11KV/200A, MEI make at Teesta building by removing the breaker from panel discmantling carefully its parts/accessories. Cleaning the dust/impurities and accumulations etc blowering/brushing cleaning properly with CRC-26 spray to remove rust including supply of gasket, oil seal, nut & bolts, washers, reassembles, the parts /accessories and fix in same position and connection, testing for satisfactory operation all as directed. (Note: Maintenance /repairs shall be carried out by trained technicians/mechanic (ii) All repairs shall be carried out at site only. Necessary testing,/measuring instrument shall be brought at site by the contractor at the time of work and all cost on this account should be included in the quoted rate)
1
-
-
... More
Removing existing old paint by scraping from Vacuum Circuit Breaker/VLE and applying two coats of synthetic enamel paint (1st quality) by spraying including writing SM/MES No, capacity in white paint complete all as specified and directed.
4
-
-
... More
Supply and replacement of heating coil of Vacuum Circuit Breaker including taking down old unserviceable all as specified as directed .
4
-
-
... More
Supply and replacement of Trip Coil Box Assembly with Plunger - without Coil as per existing type and size complete all as specified and directed.
2
-
-
... More
Supply and replacement of Busbar Support Insulator complete all as specified and directed.
1
-
-
... More
Supply and replacement of Release/Closing Coil complete all as specified and directed.
2
-
-
... More
Supply and replacement of HRC Fuse-PT HT Side VTF 6.6, 3A complete all as specified and directed.
2
-
-
... More
Supply and replacement of Potential transformer of Vacuum Circuit Breaker (Model and type as per sample) including taking down old unserviceable all as specified as directed .
2
-
-
... More
Supply and replacement of current transformer of Vacuum Circuit Breaker (Model and type as per sample) including taking down old unserviceable all as specified as directed .
2
-
-
... More
Supply and replacement of Power pack unit of Vacuum Circuit Breaker (Model and type as per sample) including taking down old unserviceable all as specified as directed .
1
-
-
... More
Calibration of relays of Vacuum Circuit Breaker with secondry injection unit and check the healthiness of relays and adjust the realy settings as per ground requirements complete all as specified and as directed.
Note: Report of calibration to be submitted to the department.
1
-
-
... More
Supplying and laying synthetic Rubber insulated mats 2.5 mm thick for voltage upto 11 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m complete all as specified and directed.
4
-
-
... More
Supplying and laying synthetic Rubber insulated mats 2 mm thick for voltage upto 3.3 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m complete all as specified and directed.
4
-
-
... More
Disconnecting, repair and maintenance of APFC panel and replacement of internal wiring by new, checking and taking out defective unserviceable parts and replaced the same to make serviceable connection, testing etc. as directed. Note: (i) Maintenance / repairs shall be carried out by trained technicians/mechanic under supervision of qualified electrical technician. (ii) All repairs shall be carried out at site only. (iii) Spare / parts shall be measured and paid seperately as ''supply only''
3
-
-
... More
Supply only 5 to 15 KVAR capacitor, box series type-LTXL-Ultra heavy duty, 440V, including taking down old unserviceable all as specified as directed.
3
-
-
... More
Supply only 20 to 50 KVAR capacitor, box series type-LTXL-Ultra heavy duty, 440V, including taking down old unserviceable all as specified as directed.
1
-
-
... More
Supply only APFC Relay meter (8 Steps) complete including taking down old unserviceable all as specified as directed .
.
1
-
-
... More
Supply only capacitor duty contractors of 5 KVAR rating, type MO C5, size Fr 1 including taking down old unserviceable all as specified as directed .
1
-
-
... More
Supply only capacitor duty contractors of 10 KVAR rating, type MO C10, size Fr 1 including taking down old unserviceable all as specified as directed .
2
-
-
... More
Supply only capacitor duty contractors of 20 KVAR rating, type MO C20, size Fr 1 including taking down old unserviceable all as specified as directed .
2
-
-
... More
Supply and fixing MCCB, 16-125 Amps, 4 pole, 36 KA breaking capacity 415 Volts with necessary cable lugs complete all as specified and directed including taking down old burnt/unserviceable one complete all as specified and directed.
3
-
-
... More
Supply and fixing MCCB, 160 Amps, 4 pole, 36 KA breaking capacity 415 Volts with necessary cable lugs complete all as specified and directed including taking down old burnt/unserviceable one complete all as specified and directed.
3
-
-
... More
Supply and fixing MCCB, 200 Amps, 4 pole, 36 KA breaking capacity 415 Volts with necessary cable lugs complete all as specified and directed including taking down old burnt/unserviceable one complete all as specified and directed.
2
-
-
... More
M & L Cable jointing kit for 11 KV (Earthed) grade cable for straight though heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm incl cutting of old jointing material including taking down old one complete all as specified and as directed.
1
-
-
... More
M&L Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm sqmm cutting of old jointing material including taking down old one complete all as specified and as directed.
1
-
-
... More
M & L Cable jointing kit for 1100 V grade cable for straight though (cold applied insulation and sealing system) heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 185-300 sqmm incl cutting of old jointing material including taking down old one complete all as specified and as directed.
1
-
-
... More
M & L Cable jointing kit for 1100 V grade cable for straight through (cold applied insulation and sealing system) heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 70-150 sqmm incl cutting of old jointing material including taking down old one complete all as specified and as directed.
2
-
-
... More
M & L Cable jointing kit for 1100 V grade cable for straight through (cold applied insulation and sealing system) heat shrink type joint complete with jointing material and accessories suitable for 3.5/4.0 core XLPE armoured aluminium conductor cable of size 25-50 sqmm incl cutting of old jointing material including taking down old one complete all as specified and as directed.
2
-
-
... More
Supply and laying in trenches or fixing or passing through pipes or fixed to wall/in trenches 1100 volts grade XLPE insulated armoured heavy duty electric cables (conforming to IS 7098 (Part- I)with aluminium conductor of cross sectional area 10 Sqmm 4 coreincluding taking down old one complete all as specified and as directed.
100
-
-
... More
Supply and laying in trenches or fixing or passing through pipes or fixed to wall/in trenches 1100 volts grade XLPE insulated armoured heavy duty electric cables (conforming to IS 7098 (Part- I)with aluminium conductor of cross sectional area 25 Sqmm 3.5 core including taking down old one complete all as specified and as directed.
92
-
-
... More
Supply and laying in trenches or fixing or passing through pipes or fixed to wall/in trenches 1100 volts grade XLPE insulated armoured heavy duty electric cables (conforming to IS IS 7098 (Part- I)with aluminium conductor of cross sectional area 35 Sqmm 3.5 core including taking down old one complete all as specified and as directed.
50
-
-
... More
Supply and laying in trenches or fixing or passing through pipes or fixed to wall/in trenches 1100 volts grade XLPE insulated armoured heavy duty electric cables (conforming to IS 7098 (Part- I)with aluminium conductor of cross sectional area 50 Sqmm 3.5 core including taking down old one complete all as specified and as directed.
100
-
-
... More
Supply and laying in trenches or fixing or passing through pipes or fixed to wall/in trenches 1100 volts grade XLPE insulated armoured heavy duty electric cables (conforming to IS 7098 (Part- I)with aluminium conductor of cross sectional area 70 Sqmm 3.5 core including taking down old one complete all as specified and as directed.
50
-
-
... More
Supply and laying in trenches or fixing or passing through pipes or fixed to wall/in trenches 11000 volts grade XLPE insulated armoured heavy duty electric cables (conforming to IS 7098 (Part- II) with aluminium conductor of cross sectional area 95 Sqmm 3 core including taking down old one complete all as specified and as directed.
50
-
-
... More
Supply only , 1100 volts grade PVC insulated and FR PVC round sheathed, copper conductor (flexible) industrial cable of cross sectional area 10 Sqmm 4 core conforming to IS 694 with suitable size of lugs (02 sets) on a drum with handle with movable trolley (one for 100 RM length) complete all as specified and as directed.
100
-
-
... More
Supply & fix hot dip galvanized steel perforated cable tray with tray cover rectanglar type (rigid & felxible) of suitable width ranging from 4 inch to 8 inch to be fixed on wall complete all specified and as directed.
25
-
-
... More
M&L for painting of perforated cable tray and cover of width 4-8 inch with two coats of powder coated paint (1st quality) of approved colour by brush after removing all dust/rust all as specified and as directed.
40
-
-
... More
Excavating in trenches n. exc. 1.5 m. wide and n. exc. 1.5 m. in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pire holes, etc. n. exc. 10 sqm on plan and not exc. 1.5 m. in depth and getting out in soft/loose soil complete all as specified and as directed.
75
-
-
... More
Returning filling including spreading levelling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil complete all as specified and as directed.
47
-
-
... More
Removing excavated soil not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point in soil complete all as specified and as directed.
28
-
-
... More
M&L for sand filling for cable cushioning including spreading and levelling as directed.
Note : Thickness for sand shall be measured after punning down.
12
-
-
... More
M & L Bricks, common burnt clay building bricks, old size sub-class ‘B’ designation 75 laid perpendicular to the axis of cable,abutting 10 mm gap in between complete all as specified and directed.
2000
-
-
... More
M&L for re- laying old brick perpendicular to the axis of cable,abutting 10 mm gap in between complete all as specified and directed.
750
-
-
... More
Supplying and laying reinforced precast concrete cable cover class HV, Type 1, flat, size 300mmx 180mm x 40mm all as specified and as directed.
30
-
-
... More
M & L Tubes, 'light grade', galvanised,with all fitting,laid in trenches/fixed on Wall 80 mm dia for protection of cable all as specified and directed.
12
-
-
... More
M&L for road cutting for laying of LT UG cable /Galvanised Iron Pipe complete all as specified and directed.
6
-
-
... More
M&L plain cement concrete 1:3:6 Type C1 (using 20 mm graded crushed stone aggregate) as in coping, roof kerb or similar work, rounded or chamfered on edges including necessary form work including demolition old one complete all as specified and directed.
2
-
-
... More
Earthing complete with GI earth plate electrode of size 60 x 60 x 0.6 cms burried directly in ground vertically at a depth of not less than 2.25 Mtrs below normal ground level with top edge of the earth plate at a depth not less than 1.5 Mtr below normal ground level surrounded from all sides by 15 cms thick and packed layer of charcoal dust and common salt filling in alternate layers etc and connected to and including GI earth strip 25 x 4 mm size upto 7.5 mtr by means of bolts, nuts, checknuts and washers made out of galvanised iron and protected by medium grade 50 mm dia 5 mtr long and connected to main control panel and GI pipe 20 mm medium grade as watering pipe including funnel, wire mesh, PCC Pit made up of PCC 1:2:4 type C2 and RCC cover 40 mm thick with 8 mm bar 15 c/c including excavation and earth work all as specified in SSR Part 1 2009.
3
-
-
... More
M & L Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 25x4 mm galvanised iron strip complete incl saddles if required.
15
-
-
... More
M&L for PCC Pit for earthing made up of PCC 1:2:4 type C2 and RCC cover 40 mm thick with 8 mm bar 15 c/c including water pipe with funnel and wire mesh and also includes excavation and earth work all as specified in SSR Part 1 2009.
1
-
-
... More
Repair/maint of LT Panel/Feeder pillar boxes by disconnecting all incomming and outgoing cable, check all internal wiring, voltmeter, ammeter, selector switches, RYB indicator lamps and re-connection after complete panel wiring with industrial copper multistranded unsheathed wire 16 Sqmm Single core (approx length 5 RM) with color code per phase and neutral with necessary cable ties, copper lugs at end the same complete with all respect incl insulation tape etc all as specified and directed by Engr in Charge.
4
-
-
... More
S &F Indicator LED phase lamps 03 Nos (R, Y, B) including taking down old one complete all as specified and as directed.
5
-
-
... More
S & F Volt meter 0-500 Volts Digital Type including taking down old one complete all as specified and as directed.
3
-
-
... More
S & F Ammeter 0-500 Amps Digital Type including taking down old one complete all as specified and as directed.
3
-
-
... More
S & F selector switch 3 /4 position including taking down old one complete all as specified and as directed.
4
-
-
... More
M&L for painting of LT panels, APFC pannel, feeder pillar boxes, junction boxes, sheet metal enclosure and any other steel surfaces complete with two coats of powder coated paint (1st quality) of approved colour by spraying after removing all dust/rust /grease including preparation surface all as specified and directed.
4
-
-
... More
M&L for shifting of LT panel from one location to another by disconnecting and/or terminating old connection, removing foundation PCC and fixing at new location if required all as specified and as directed.
Note: 1. Transportation cost deemed inclusive of the quoted rate.
2. PCC for foundation shall be measured and paid separately.
2
-
-
... More
Supply and fix sheet steel enclosure 4 way TPN DB with 200 amps bus bar with provision for TPN MCB as incomer, double door type complete all as specified and directed.
Make: Legrand/ABB/L&T/Siemens/Schenieider.
1
-
-
... More
Supply and fix MCB TPN 240V, 16-32 Amps capacity 'C' Curve complete all as specified and directed.
8
-
-
... More
Supply and fix MCB TPN 240V, 40-100 Amps capacity 'C' Curve complete all as specified and directed.
6
-
-
... More
Supply only Aluminium cable lugs suitable for XLPE armourded cable for cable size of 16-300 sqmm with 3.5/4.0 core all as specified and as directed.
75
-
-
... More
Supply only Aluminium ferrules suitable for XLPE armourded cable for cable size of 16-300 sqmm with 3.5/4.0 core all as specified and as directed.
75
-
-
... More
Supply and fix in repairs on load change over switch with phase barriers, handles with door interlocking kit with enclosure, 4 pole, 250 amps, I-O-II complete all as specified and as directed by Eng-in-charge.
1
-
-
... More
Supply only High temperature, Strip finned heater 500 Watt complete as per site requirement and all as specified and as directed.
10
-
-
... More
Supply and fix Analog type time switch FM/1 QT (Daily) type , 240V AC, 50/60Hz complete including taking down and unserviceable one and all as per site requirement and as specified and directed.
2
-
-
... More
Supply and fix Base frame of Heavy duty MS "I" beam dimension 200 mm (Depth) X 200 mm(Width) X 9 mm (Flange thickness) X 6.1 (Web Thickness) for VCB / DG / transformer mounting including all fittings and fixtures as per site requirement and all as specified and as directed.
250
-
-
... More
S&F PVC Sign Board with details acrylic sandwich sheet board waterproof for display with 10 mm thickness and of suitable size complete all as specified and as directed.
2
-
-
... More
Maintenance and servicing to carry out B-check to Diesel Engine set of capacity of 75 KVA , AC 3 phase 415 Volts 50 HZ 0.8 PF 1500 RPM Make : Kirloskar, by changing lubrication oil, lube oil filter, checking of cooling system, changing of fule oil filter and water separator, cleaning of air filter incl including greasing, tightening of foundation/base frame nut bolts & other loosen parts of body cleaning of fuel tank, arresting any leakage and carrying out all A- checks as per OEM by authorised technician as required and testing complete all as as specified and directed. Note:- (i) Price of minor spares deemed inclusive of quoted rate. Spare required Shall be measured and paid as supply only under respective items in this schedule.
(ii) Servicing report to be submitted to the department.
1
-
-
... More
All as per item No 81 but for 160 KVA capacity and Make-Cummins all as specified and as directed.
2
-
-
... More
All as per item No 81 but for 90 BHP capacity and Make-Kirloskar all as specified and as directed.
1
-
-
... More
All as per item No 81 but for 115 KVA capacity and Make-Kirloskar all as specified and as directed.
1
-
-
... More
All as per item No 81 but for 125 KVA capacity and Make-Kirloskar all as specified and as directed.
1
-
-
... More
All as per item No 81 but for 75 KVA capacity and Make-Ashok Leyland all as specified and as directed.
1
-
-
... More
All as per item No 81 but for 60 KVA capacity and Make-Ruston all as specified and as directed.
1
-
-
... More
All as per item No 81 but for 82.5 KVA capacity and Make-Ashok Leyland all as specified and as directed.
1
-
-
... More
Supply only gasket for bellow all as specified and as directed.
2
-
-
... More
Supply only Lube oil 15 W 40 grade all as specified and as directed.
100
-
-
... More
Supply only Lube oil filter and element including taking down old one all as specified and as directed.
8
-
-
... More
Supply only element-pre filter including taking down old one all as specified and as directed.
8
-
-
... More
Supply only lube oil pressure switch including taking down old one all as specified and as directed.
4
-
-
... More
Supply only diesel filter and element including taking down old one all as specified and as directed.
8
-
-
... More
Supply only air filter and element including taking down old one all as specified and as directed.
8
-
-
... More
Supply only exhaust bellow including taking down old one all as specified and as directed.
2
-
-
... More
Supply only oil pressure sensor including taking down old one all as specified and as directed.
2
-
-
... More
Supply only coolant including all as specified and as directed.
140
-
-
... More
Supply and fix relay board for DG set including calibration including taking down old one all as specified and as directed.
2
-
-
... More
Supply and fix 3 Ph automatic voltage regulator for DG set including taking down old one all as specified and as directed.
1
-
-
... More
Supply and fix Digital PCB Controller for DG set including taking down old one all as specified and as directed.
1
-
-
... More
Supply and fix contactor for DG set of capacity 75 to 160 KVA including taking down old one all as specified and as directed.
1
-
-
... More
Supply and fix Solenoid switch with all necessary accessories for DG set including taking down old one all as specified and as directed.
2
-
-
... More
Supply and fix fan belt all as specified and as directed.
2
-
-
... More
S&F Asbestos rope 10 mm dia for suitable for exhaust pipe of DG Set complete including taking down old unserviceable one complete all as specified and directed .
20
-
-
... More
Supply and fixing in repair of AMF panel by disconnecting all incoming and outgoing cable,checking one by one circuits, fuse, meter, contactors, relay, automatic charger unit etc. checking all cable connections by testing equipments for continuity & efficiency on load applied. Replace the wornout parts,wornout spares breaker,fuse with carrier,circuit boards and automatic charger repalced by new one with necessary connection and make the panel in complete serviceable condition and panel run satisfactory complete all as specified and directed.
1
-
-
... More
S & F Water temperature gauge suitable for DG Set of capacity DG Set of capacity 60 to 160 KVA, AC 3 phase, 415 Volts, 50 HZ, 0.8 PF, 1500 RPM including taking down unserviceable one all as specified and as directed.
2
-
-
... More
S & F RPM meter suitable for DG Set of capacity 60 to 160 KVA, AC 3 phase, 415 Volts, 50 HZ, 0.8 PF, 1500 RPM including taking down unserviceable one all as specified and as directed.
2
-
-
... More
S & F KWH meter (analog/digital as per sample) suitable for DG Set of capacity 60 to 160 KVA, AC 3 phase, 415 Volts, 50 HZ, 0.8 PF, 1500 RPM including taking down unserviceable one all as specified and as directed.
2
-
-
... More
S&F cable for Speedometer, KWH meter or other gauges in suitable length suitable for DG Set of capacity 60 to 160 KVA, AC 3 phase, 415 Volts, 50 HZ, 0.8 PF, 1500 RPM including taking down unserviceable one all as specified and as directed.
2
-
-
... More
M&L for replacement of rubber hoses for radiator in suitable length in & out incl all necessary accessories including taking down unserviceable one all as specified and as directed.
2
-
-
... More
M&L for replacement of rubber hoses for fuel/lubricant in suitable length in & out incl all necessary accessories including taking down unserviceable one all as specified and as directed.
2
-
-
... More
Supply and fixing battery 12 volt, 180 AH including taking down unserviceable battary complete all as specified and as directed.
2
-
-
... More
Repair / overhauling and servicing radiator for 60 KVA/75 KVA/115 KVA /125 KVA Fire fighting /Generator Engine Set by (a) Dismantling and re-installing and commissioning in the same position after repair.(b) after dismantling the complete readiator part by part and cleaning thoroughly by acid with water and de-scaling all the sludge. (c) blazing all the leacking points after cleaning and must be leakage proof incl machine shop for grinding & pressure test etc as required and testing complete all as as specified and directed. Note:- Any minor item required Shall be deemed included in the quoted rate
5
-
-
... More
Material and labour for rewinding including taking down of the burnt winding for Alternator of capacity 60-160 KVA DG Set, with water proof enameled copper wire of existing gauge, cleaning of stator and rotor parts including replacement of bush, bearing, sleve, lugs, heat vernising (1st quality), cheking all electrical and mechanical parts and repair/ replace of old unserviceable parts, refixing and testing properly complete all as specified and as directed. NOTE: Quoted rate is inclusive of transportation from installation to workshop and back.
1
-
-
... More
S&F On-Load change over switch I-O-II,WITH SS Enclourse of 250Amp 4pole,415V, complete including taking down U/S one all as specified and directed.
1
-
-
... More
Taking out self starter, of stand by DG Set cap. 60 -160 KVA opening and segregating serviceable & unserviceable parts,cleaning the serviceable parts for re-use, greasing,Oiling re-assembling the self starter including replacement of following unserviceable parts :-
(a) Carbon bushes
(b) Brass plunger (c) Funnel coil (d) Body brass nut
3
-
-
... More
Supply, installation, testiting and commissioning Retrofit Emission Control Device (RECD) Regeneration Filter Type made up of SS 316 Digital output RS 485 RTU, High heat resistance, Low exhaust resistance, Auto bypass system with respect to back pressure in existing Diesel Generator of cap 75 KVA/48 Kw (Manufactured year : 1990 ) by removing the exhaust vent pipe and refixing the same after installing the device including making good to the plant and surface complete all as specified and directed. Make: Vasthi Engineers Pvt Ltd (Model No: VE-REF 71162.5)NOTE: (i) The emission limits for DG Sets up to 800 KW is to be as per CPCB-II norms. (ii) The RECD Having a minimum specified Particulate Matter (PM) capturing efficiency of 70% type approved by CPCB recognized lab.
1
-
-
... More
Taking down old LED street light/secirity light/flood light/post top lantern/ garden light fitting of any size and any capacity from pole/ bldg/gate/garden with disconnecting the existing line for pole and cleaning the carbon of existing cable of pole box, checking driver kit replace unserviceable items and light fitting connector and refix the same on pole and testing complete all as specified and directed by Engr-in-charge. Note-LED Driver required will be measured and paid seperately.
50
-
-
... More
Supply and fix MCB SP 240V, 5-32 Amps capacity complete including taking down old unserviceable one all as specified and directed.
20
-
-
... More
Supply and fix GI Bracket made of 32/40/50 mm dia MS pipe medium grade 1.5mtr long suitable for street light on steel / RCC pole as per site requirement including suitable GI nut, bolt and clamps complete accesseries all as specified and directed Including taking out old one.
5
-
-
... More
Supply and fix MS Clamp for street light with dimension suitable to firm grip on pole and PVC conduit and fix with MS nut and bolts complete including taking down old unserviceable one all as specified and as directed.
5
-
-
... More
M&L preparation of old painted surface above the planting depth and PCC coping of steel tubular LT pole of upto 9.00 metre length with white wash including painting with synthectic enamelled MS clamps ,cable protection pipe bracket fitted with street light fittings etc by scraping with steel wire brush and applying two coats, of aluminium paint to external surface of poles MS cross arms MS clamp, cable protection pipe etc to give even shade and numbering of poles complete all as specified and as directed by Engr-in –charge.
50
-
-
... More
Supply and laying in trenches or fixing or passing through pipes or fixed to wall/in trenches 1100 volts grade XLPE insulated armoured heavy duty electric cables (conforming to IS 7098 (Part- I)with aluminium conductor of cross sectional area 10 Sqmm 4 core including taking down old one complete all as specified and as directed.
150
-
-
... More
Supply and laying in trenches or fixing or passing through pipes or fixed to wall/in trenches 1100 volts grade XLPE insulated armoured heavy duty electric cables (conforming to IS 7098 (Part- I)with aluminium conductor of cross sectional area 16 Sqmm 4 core including taking down old one complete all as specified and as directed.
60
-
-
... More
M&L for sand filling for cable cushioning including spreading and levelling as directed.
Note : Thickness for sand shall be measured after punning down.
8
-
-
... More
M & L Bricks, common burnt clay building bricks, old size sub-class ‘B’ laid perpendicular to the axis of cable complete all as specified and directed.
600
-
-
... More
M&L for re- laying old brick perpendicular to the axis of cable,abutting 10 mm gap in between complete all as specified and directed.
200
-
-
... More
M & L Tubes, 'light grade', galvanised,with all fitting,laid in trenches/fixed on Wall 50 mm dia for protection of cable all as specified and directed.
12
-
-
... More
M&L for road cutting for laying of LT UG cable /Galvanised Iron Pipe complete all as specified and directed.
12
-
-
... More
M&L plain cement concrete 1:3:6 Type C1 (using 20 mm graded crushed stone aggregate) as in coping, roof kerb or similar work, rounded or chamfered on edges including necessary form work including demolition old one complete all as specified and directed.
1
-
-
... More
Earthing complete with GI earth plate electrode of size 60 x 60 x 0.6 cms burried directly in ground vertically at a depth of not less than 2.25 Mtrs below normal ground level with top edge of the earth plate at a depth not less than 1.5 Mtr below normal ground level surrounded from all sides by 15 cms thick and packed layer of charcoal dust and common salt filling in alternate layers etc and connected to and including GI earth strip 25 x 4 mm size upto 7.5 mtr by means of bolts, nuts, checknuts and washers made out of galvanised iron and protected by medium grade 50 mm dia 5 mtr long and connected to main control panel and GI pipe 20 mm medium grade as watering pipe including funnel, wire mesh, PCC Pit made up of PCC 1:2:4 type C2 and RCC cover 40 mm thick with 8 mm bar 15 c/c including excavation and earth work all as specified in SSR Part 1 2009.
2
-
-
... More
M & L Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 25x4 mm galvanised iron strip complete incl saddles if required.
25
-
-
... More
Refixing of hanging/loosen earth strip/down conductors of Cu/GI/Al with replacement of broken procelain connector and proper clamping, saddling and connected accessories at the original location complete all as directed.
Note: Price of porcelain connector any scaffloding required deemed inclusive of quoted rate.
50
-
-
... More
Supply & fix Air termination single pointed aluminum rod 12 mm dia and 300 mm long including taking down old unserviceable one complete all as specified and as directed.
2
-
-
... More
Supply & fix Test point terminal block made of gunmetal or phosphorus bronze of size 75 x 75 x 25 mm, drilled and screwed including 3 nos 8 mm dia 25 mm long hex head screw complete all as specified and as directed including taking down old unserviceable one.
4
-
-
... More
M&L for outdoor LT Panel cubicle compartmentalized type panel of suitable size with 3.15 mm thick CRCA sheet with 2.0 mm thick gland plate suitable for IP 52 protection, phosphate powder coated in Siemens grey colour with suitable size of Al Bus bar with heat colour coded sleeve with provision of cable entry from bottom & top, supported on MS angle of size 40 x 40 x 6 mm complete with all fittings and fixing arrangement all as specified and as directed with following specifications:-
Note: 1. Switchgears and metering equipment will be provided by department.
2. Busbars and internal wiring and connector deemed inclusive of the quoted rate.
3. Any minor spares deemed inclusive of the quoted rate.
4. PCC for foundation deemed inclusive of the rate.
1
-
-
... More
M&L for indoor LT Panel cubicle compartmentalized type panel of suitable size with 1.6 mm thick CRCA sheet with 2.0 mm thick gland plate suitable for IP 52 protection, phosphate powder coated in Siemens grey colour with suitable size of Al Bus bar with heat colour coded sleeve with provision of cable entry from bottom & top complete with all fittings and fixing arrangement all as specified and as directed with following specifications:-
Note: 1. Switchgears and metering equipment will be provided by department.
2. Busbars and internal wiring and connector deemed inclusive of the quoted rate.
3. Any minor spares deemed inclusive of the quoted rate.
4. PCC for foundation deemed inclusive of the rate.
1
-
-
... More
Repair/maint of LT Panel/Feeder pillar boxes by disconnecting all incomming and outgoing cable, check all internal wiring, voltmeter, ammeter, selector switches, RYB indicator lamps and re-connection after complete panel wiring with industrial copper multistranded unsheathed wire 16 Sqmm Single core (approx length 5 RM) with color code per phase and neutral with necessary cable ties, copper lugs at end the same complete with all respect incl insulation tape etc all as specified and directed by Engr in Charge.
5
-
-
... More
S &F Indicator LED phase lamps 03 Nos (R, Y, B) including taking down old one complete all as specified and as directed.
2
-
-
... More
S & F Volt meter 0-500 Volts Digital Type including taking down old one complete all as specified and as directed.
2
-
-
... More
S & F Ammeter 0-500 Amps Digital Type including taking down old one complete all as specified and as directed.
2
-
-
... More
S & F selector switch 3 /4 position including taking down old one complete all as specified and as directed.
10
-
-
... More
Supply and fix electronic driver for LED flood light/street light as per existing capacity including fitting arrangements and taking down old one complete all as specified and as direted.
15
-
-
... More
Supply and fix electronic driver for LED bollard light/post top lantern/spot light as per existing capacity including fitting arrangements and taking down old one complete all as specified and as direted.
10
-
-
... More
Supply and fix flood LED light in 250 W in static mono colour or as specified by Engr-In-Charge with IP 66 protection with all fittings and accesories complete all as specified and as directed.
6
-
-
... More
M&L for Decorative post top lantern for 360 degree , 20 Watt, indirect light suitable for pipe 50mm dia including connection from connector to switch including taking down old one complete all as specified and as directed.
6
-
-
... More
S & F of Flood light 200 W with minimum system efficacy 100 lum/W including electronic driver and all fixing arrangement including taking down old one all as specified and as directed.
4
-
-
... More
Supply and fixing LED street light fitting 70 watt 230 V AC outdoor type with high pressure die cast aluminiun housing and heat resistant complete with driver, lamp bracket with impact and corrosin resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed by Eng-in charge.
10
-
-
... More
S&F Sign Board with details made of acrylic sheet board waterproof for display with 2.5 ft height x 6 ft width with 12 mm thickness fixed with SS clamp complete all as specified and as directed.
Note: Subject material to be provided by the department.
2
-
-
... More
S & F water supply/electric supply/fire fighting network diagram chart acrylic PVC sheet with size 5 ft x 3ft with 4 mm thickness complete all as specified and directed by engr-in-charge.
2
-
-
... More
Supply and fix sheet steel enclosure 4 way TPN DB with 200 amps bus bar with provision for TPN MCB as incomer, double door type complete all as specified and directed.
4
-
-
... More
Supply and fix MCB TPN 240V, 16-32 Amps capacity 'C' Curve complete all as specified and directed.
6
-
-
... More
Supply and fix MCB TPN 240V, 40-100 Amps capacity 'C' Curve complete all as specified and directed.
4
-
-
... More
Supply and fix Contactor ML-2, 3 pole 240 Volts including taking down old burnt/unserviceable one complete all as specified and directed.
2
-
-
... More
Supply and fix main CTs as per existing capacity including taking down old burnt/unserviceable one complete all as specified and directed.
4
-
-
... More
Supply & fix street light timer suitable for street light control complete all as specified & directed including taking down old one all as specified and directed.
4
-
-
... More
Supply and fix SMC junction box fix to wall/pole , Size - 300 x 200 mm, with provision of cable incoming and outging including cable glands and 4 Pole PVC Connector all fittings including taking down old unserviceable one all as specified and as directed.
10
-
-
... More
M&L for wiring with two runs of 1.5 sqmm (Nominal area) single core PVC insulated stranded unsheathed copper conductor FRLS cable upto and including 1100 V grade drawn through PVC rigid conduit medium grade fixed to wall / ceiling / pole etc including one run of 1.5 sqmm (nominal area) single core, PVC insulated stranded unsheathed copper conductor FRLS cable as earth wire and duly connected to common earth point all as specified and directed including taking out old cables. (Note :-(i) One run of PVC rigid conduit with all fittings/accessories and Two runs of 1.5 sqmm single core cable and one run of 1.5 sqmm earth continuity wire to be measured as one length).
120
-
-
... More
Supply and fixing LED street light fitting 120 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specifed and as directed.
4
-
-
... More
Supply and fixing in repair LED bollard light in cylindrical shape with opal acrylic diffuser and IP66 protection including taking down old u/s one complete all as specified and as directed.
4
-
-
... More
Supply and laying double wall corugated pipe internal dia 75 mm dia, IS 16205-Part-24-2018 with coupler, bends etc for mechanical protection of LT cables for relaying new cables complete all as specified and directed
15
-
-
... More
Supply and fixing LED street light fitting 45 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specifed and as directed.
5
-
-
... More
M&L for Decorative post top lantern for 360 degree , 40 Watt, indirect light suitable for pipe 50mm dia including connection from connector to switch including taking down old one complete all as specified and as directed.
4
-
-