Military Engineer Services Tender

Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date5 Sep 2024
Closing Date3 Oct 2024
Tender Amount₹ 72,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Material and labour for disconnecting the transformer (Indoor/ Outdoor type) from Plinth/Pole mounted from all connection primary and secondary with earthing after faulty transformer loading on vehicle and carrying to workshop for repair and replacement of old worn out and u/s items as well as winding etc including unloading at the workshop capacity of transformer 25 KVA to 100KVA, complete all as specified and as directed. . Note :- All tools, plants and vehicle for lifting and shifting the transformer shall be arranged by the contractor and not extra payment shall be paid to the contractor for the same.

2

-

-

... More
All as per srl item No 4 here in before but 125 KVA to 200 KVA.

1

-

-

... More
All as per srl item No 4 here in before but 250 KVA to 400 KVA.

1

-

-

... More
All as per srl item No 4 here in before but 500 KVA

2

-

-

... More
M&L for dismantling the top cover of the defective transformer of capacity 25 KVA to 100 KVA 11/.433KV after drained out the existing oil in a separate clean container and disconnecting the all internal connection, taking out the HV/ LV core assembly andmMagger the winding for identifying the fault/defective winding, seggregating the defective winding portion/taking out, cleaning the laminated core rewinding with appropriate gauge winding wire of existing description for transformer, cleaning the transformer chamber (body) inside and out side thoroughly with emery paper and cloth than checking the other worn-out parts and insulation materials such as glass tube, bakelight tube, tap changer,glass tape, pre-compressed board, crape paper,craft paper, pressphan paper, cotton tape, varnish etc , HV/LV coils silicon stamping and other connected items such as tap-changer, breather assembly, damage HV/LV bushes, stud, oil seal, Gas kit and replacement of all burn out parts and insulation material with new ones by drying and baking of Insulating material in heating chamber in adequate temprature. Reassenbling the transformer and made connection of LV/HV side with help of soldering.Testing of transformer after reassembly complete on No load at wkshop and on load at site all as specified and directed. Note :- (i) Winding wire/strip of HV/LV coils, transformer oil and other spare pafrts shall be measured & paid seperately on relevant items of the schedule. (ii) Gasket, Copper / Aluminum thimble, HT/ LT Tape, insulation materials such as glass tube, bakelight tube, tap changer,glass tape , pre-compressed board, crape paper,craft paper, pressphan paper, cotton tape, varnish etc , HV/LV coils silicon stamping and other connected items, HV/LV coils silicon stamping for any size of transformer will be included in the quoted rate . No extra amount shall be paid to the contractor for the same. (iii) The transformer will be opened and reassembled in presence of Egnr-in-charge / JE in charge.

2

-

-

... More
All as per srl item No 8 here in before but 125 KVA to 200 KVA.

1

-

-

... More
All as per srl item No 8 here in before but 250 KVA to 400 KVA.

1

-

-

... More
All as per srl item No 8 here in before but 500 KVA

2

-

-

... More
Supply of E.C Grade DPC/super enamelled copper winding wire/Strip for made out of HV coils of transformer capacity 25 KVA to 500 KVA coils should be replaced as per existing number of turns, gauge, insulation value matching with OEM designed complete all as specified and directed.

375

-

-

... More
Supply of E.C Grade DPC/super enamelled copper winding wire/Strip for made out of LV coils of transformer capacity 25 KVA to 500 KVA coils should be replaced as per existing number of turns, gauge, insulation value matching with OEM designed complete all as specified and directed.

240

-

-

... More
Supply of E.C Grade DPC/super enamelled alluminium winding wire/Strip for made out of HV coils of transformer capacity 25 KVA to 500 KVA coils should be replaced as per existing number of turns, gauge, insulation value matching with OEM designed complete all as specified and directed.

230

-

-

... More
Supply of E.C Grade DPC/super enamelled alluminium winding wire/Strip for made out of LV coils of transformer capacity 25 KVA to 500 KVA coils should be replaced as per existing number of turns, gauge, insulation value matching with OEM designed complete all as specified and directed.

160

-

-

... More
Supply ony HV Porcelain Bushing including brass stud and nut as per existing size suitable for transformer capacity 25 to 100 KVA, complete all as specified and as directed.

5

-

-

... More
All as per srl item No 16 here in before but 125 KVA to 200 KVA. 11/.433KV.

3

-

-

... More
All as per srl item No 16 here in before but 250 KVA to 400 KVA 11/.433KV.

3

-

-

... More
All as per srl item No 16 here in before but 500 KVA 11/.433KV.

5

-

-

... More
Supply ony LV Porcelain Bushing including brass stud and nut as per existing size suitable for transformer capacity 25 to 100 KVA of 11/.433KV complete all as specified and as directed.

6

-

-

... More
All as per srl item No 20 here in before but 125 KVA to 200 KVA.

4

-

-

... More
All as per srl item No 20 here in before but 250 KVA to 400 KVA.

4

-

-

... More
All as per srl item No 20 here in before but 500 KVA

5

-

-

... More
Supply only new tap changer for adjusting the voltage with brass parts as per sample of existing for indoor/ outdoor type transformer 25 KVA To 100 KVA, complete all as specified and as directed.

1

-

-

... More
All as per srl item No 24 here in before but 125 KVA to 200 KVA.

1

-

-

... More
All as per srl item No 24 here in before but 250 KVA to 400 KVA.

1

-

-

... More
All as per srl item No 24 here in before but 500 KVA.

1

-

-

... More
Supply only silica gel in breather assembly different capacity of transformer, complete all as specified and as directed.

18

-

-

... More
Supply and fixing in repair breather assembly transparent MS body with top and bottom portion pressed with mettalic cover size 0.250 Kg suitable for fixing on existing pipe of size 15/20/25 mm bore as per site requirement and for transformers capaciy of 25 KVA to 100 KVA capacity, including silicajel, complete all as specified and as directed.

8

-

-

... More
All as per srl item No 29 here in before but size 0.500Kg suitable for 125 KVA to 400 KVA.

12

-

-

... More
All as per srl item No 29 here in before but size 1 Kg suitable for 500KVA.

5

-

-

... More
M&L for Spray painting for the capacity of power transformers 25 to 100 KVA 11/.433KV by preparing the surfaces and removing all type of grease, oil, dust and all other substance and applying one coat of approved colour synthetic enamel 1st grade finishing with light greay paint to main tank, Fins and other parts of transformer including writing of SM/MES No by white colour colour synthetic enamel paint, complete all as specified and as directed.

15

-

-

... More
All as per srl item No 32 here in before but 125 KVA to 200 KVA.

12

-

-

... More
All as per srl item No 32 here in before but 250 KVA to 315 KVA.

10

-

-

... More
All as per srl item No 32 here in before but 400 to 500 KVA

8

-

-

... More
Supply and fixing in repair of protection cover for LT and HT side of the outdoor type transformer of any capacity upto 400 KVA , the protection cover should be made out of 3 mm dia CRCA sheet in rectangular, triangular or square shape and fixing the same cover by means of nuts, bolts, etc including applying one coat of red oxide and two coat of super enamel paint over the exposed surface of the box, complete all as specified and as directed.

10

-

-

... More
M&L for Vaccume dehydration with hot filteration plant of old transformer oil at different locations, after filteration, Di electric strength shall not be less than 60 KV in 2.5 mm gap electrode, complete all as specified and as directed. The contractor shall submit necessary Test Report for Di electric strength before dehyderation as well as after dehyderation as per relevant IS. The contractor's quoted rates shall also be declered to include for this element. Note:- (i) Toping up of transformer Oil during the dehyderation shall be measured and paid separately on relevant items of schedule. (ii) The contractor must have own one dehydrated hot vacuum, filtration plant with minimum 1000 liter per hour capacity transformer oilf Filtration plant with a provision of oil test set for immediate showing of result. (iii) The plant must have provision of on load filtration. Dehydration and filteration of transformer oil at site by using dehydrating and filteration machine to be carried out till time, dielectric strength reached to min 60 KV complete all as specified and directed. (iv)The transformer dehydration machine shall be arrange/brought by contractor at site for which and no extra amount shall be paid to the contractor. (v) The contractor shall submit necessary Test Report for Di electric strength before dehyderation as well as after dehyderation from CPRI /Govt approved Lab as per relevant IS. The contractor's quoted rates shall also be declared to include for this element. (vi)Transformer Oil after dehyderation shall be measured and considered for the payment under the item.

15000

-

-

... More
Supply and fixing of the temperature gauge of the different type and capacity of tranformer 25 to 500 KVA complete all as specified and as directed.

15

-

-

... More
Material and labour for toping up of the transformer oil conforming to IS-335 (make : POWER OIL/HP/BP/TRANSOL/POWER LINK) with new transformer Oil having dielectric strength not less than 60 KV complete all as specifed and as directed. Notes:- Quoated rate shall also be deemed to include for testing of transformer oil from CPRI / Govt. approved lab as per relevant IS and submission of necessary test reports.

2500

-

-

... More
M&L for carrying out the Periodical Check and preventive maintenance/servicing of HT VCB 11 KV, 630A/400A as per existing make/model alongwith tripping system and mechanism including taking out Breaker/trolley and carried out the fwg repair/tests made for smooth operationnof VCB: (a) Cleaning and greasing of mechanism. (b)Tightning testing of mechanism parts. (c ) Alignment testing and adjustment of mechanism. (d) Operation, testing of trip and close by electrical and manual mode. (e) Spring charging testing by electrical and manual mode. (f) Cleaning of panel insulator CT & PT unit of the panel. (g) Cleaning and repair/tightning of control/wiring CT & PT unit.(h) Cleaning and testing of relay with current injection method (j) Testing of auxillary relay.(k) Allingment of trolley, checking/greasing of shutter /lock of breaker.(l) Testing of polarities of CTs.(m) Checking and recording of IR Values of VCB trolley and Panel. (n) Settings and coordination of relays. (o) Checking/repairing/rectification of the control wiring. (p) Replacement of panel heater.(q) Replacement of worn out bushing PT/Busbar support insulators rusted nuts bolts and washer with suitable size of stainless steel nuts, bolts and washers.(r) Replacement of all unserviceable CTs. (s) Replacement of unserviceable Relay, Push botton, Indicator light HRC fuse and all other spare as required etc. (t) High voltage testing with high voltage tester of CT & Breaker Pole to withstand working pressure of HT 11 KV to ascertain serviceability and spare parts found defective to be replaced for smooth functioning as directed by the GE/Engr-in-Charge. (u) Opening the bus bar chamber of HT 11 KV VCB panel board, cleaning the bus bar chamber, inspection of the wiring of CTs, spout insulator & bus bar joints, retightening if required & heating up with hot air blower to remove moisture, meggering, HV testing, applying TRTPPEX(B) to the surfaces of bus bar & commissioning complete all as specified and as 0directed by GE/Engr-in-Charge. (v) Complete servicing, overhauling and testing of 11 KV indoor VCB Panel/breaker shall be got done by the contractor from the authorised agency as approved by the GE//Engr-in-Charge. Note: (i) Any part/spare found defective during testing shall be repaired/replaced for which payment shall be made separately against respective items here in after except for minor parts such as packing, nuts bolts, washer, cotton waste, cleaning agents,CRC spray etc for which cost shall be deemed to be included in the unit rate quoted for this item. (ii) After completion of servicing of each panel considered one Job of this item. Contractor shall deposit / Procure all the material in advance to avoid any late night fault/ after market hours / non availability of material in market. (iii) Minimun one VCB shall be produce to contractor for restand/ repair for one visit. Contractor will not demand all VCB repair in one visit. Visit and repair charges of electrician and helper are included in the quoted rate. no extra charges shall be paid to the contractor.

20

-

-

... More
Supply only steel nuts, bolts and washers in place of rusted GI nut and bolts size as per site requirment, complete all as specified and directed .

15

-

-

... More
Supply of CT unit 200/100/5-5A, 15 VA 50Hz suitable for 11KV VCB as per sample in existing site in complete all as specified.

1

-

-

... More
All as per Ser item No 42 above but CT unit 100/5-5A, 15 VA, complete all as specified and as directed.

1

-

-

... More
All as per Ser item No 42 above but CT unit 50/5A, 15 VA, complete all as specified and as directed.

4

-

-

... More
Supply only flush mounted high speed tripping relay (86) suitable for 11KV VCB 630/400A with aux volts 110 Volt DC making necessary cutting in the existing panel and necessary control wiring FRLS of size not less than 2.5 sqmm and providing Ferules for identification and necessary spares for fixing as per sample in site, complete all as specified and as directed.

3

-

-

... More
All as per item ser No 45 with 100 Volt DC as per sample at existing site, complete all as specified and as directed.

3

-

-

... More
Supply only Closing coil with 110 V DC of 11 KV VCB as per sample in site,complete all as specified and as directed.

5

-

-

... More
All as per item ser No 47 with 110 Volt DC as per sample in site, complete all as specified and as directed.

4

-

-

... More
Supply only Triping Coil with 110 V DC of 11 KV VCB as per sample in site, complete all as specified and as directed.

4

-

-

... More
All as per item ser No 49 with 100 Volt DC as per sample in site, complete all as specified and as directed.

5

-

-

... More
Supply only 3 Phase Over Current, Earth Fault Relay for existing 11 KV indoor VCB panel with high set IDMT and INST characteristics having aux supply (V) of 110 V DC, complete all as specified and as directed. Make ABB Model No. REJ601/Ashida/Schneider/Siemens.

3

-

-

... More
All as per item ser no 51 above but aux volt 30 Volt DC, complete all as specified and as directed. .

3

-

-

... More
Supply Vaccum interrupter bottle for VCB 11 KV, 630 Amps complete all as specified and directed.

6

-

-

... More
Supply and fixing in repair PT Fuse (Barrel type) ,complete all as specified and as directed.

6

-

-

... More
Supply only digital type multifuctional meter 3 Phase 4 wire flush type , complete all as specified and as directed.

2

-

-

... More
Supply only digital type ammeter inbuilt selector switch with 3Phase 4 wire flush type 96 sq mm, complete all as specified and as directed.

10

-

-

... More
Supply only digital type voltmeter inbuilt in VSS flush type 96 x96 mm as per, complete all as specified and as directed.

2

-

-

... More
Supply only Breaker Control Switch (TNC) return to neutral type 2 pole 2way with off complete all as specified and as directed.

4

-

-

... More
Ssupply only auxliary switch complete as per sample in existing site for 11 KV VCB, complete all as specified and as directed.

3

-

-

... More
Supply only LED Type indicating light colour RED, YELLOW, BLUE, GREEN, AMBER, WHITE, complete all as specified and as directed.

54

-

-

... More
Supply only push buttons red, yellow and black with aux contacts 1 NO and 1 NC, complete all as specified and as directed.

12

-

-

... More
Supply only flush type micro processor based alarm annunciator with P.B window 08 and aux voltage 110 Volt DC, complete all as specified and as directed.

2

-

-

... More
Supply only Hooter flush type 96 x 96 mm aux voltage 110 Volt DC , complete all as specified and directed.

1

-

-

... More
Supply only automatic spring charging motor operating voltage 230 Volt AC, complete all as specified and directed. Make : Schneider/Crompton/ Legrand.

4

-

-

... More
Supply only Aux relay with Aux voltage 110 Volt DC and aux contacts 2C/O or 4C/O, complete all as specified and as directed.

3

-

-

... More
Supply only Aux relay with aux voltage 30 Volt DC and aux contacts 2C/O complete all as specified and as directed.

3

-

-

... More
Supply only double space heater 80Watt each including 1.5 Sqmm wiring and thermostate suitable for 11 KV VCB of 630/400 Amp complete all as specified and as directed.

12

-

-

... More
Supply only antipumping pluge-in type relay SPD/Eq type with aux votl 24 to 110 V Dc and Aux contacts 1 NO + 1 NC,complete all as specified and as directed.

2

-

-

... More
Supply of Limit switch suitable for VCB 11000 Volt 63/400 Amps, complete all as specified and as directed.

10

-

-

... More
Supply of micro switch suitable for VCB 11000 Volt, of 630/400 Amps, complete all as specified and as directed.

5

-

-

... More
Supply of big gear assembly suitable for VCB 11000 Volt, of 630/400 Amps, complete all as specified and as directed.

4

-

-

... More
Supply of small gear assembly suitable for VCB 11000 Volt, of 630/400 Amps, complete all as specified and as directed.

4

-

-

... More
Supply of tripping shaft assembly suitable for VCB 11000 Volt, of 630/400 Amps, complete all as specified and as directed.

5

-

-

... More
Supply of closing shaft assembly suitable for VCB 11000 Volt, of 630/400 Amps, complete all as specified and as directed.

2

-

-

... More
Supply only closing segment gear assembly suitable for VCB 11000 Volt, of 630/400 Amps, complete all as specified and as directed.

3

-

-

... More
Supply only holding catch assembly for VCB 11000 Volts, 630/400 Amps, complete all as specified and as directed.

3

-

-

... More
Supply only breaker mechanism assembly for VCB 11000 Volts, 630/400 Amps, complete all as specified and as directed.

3

-

-

... More
Supply only ON/OFF push button plate assembly for VCB 11000 Volts, 630/400 Amps, complete all as specified and as directed.

10

-

-

... More
Supply only breeze rectifier for VCB 11000 Volts, 630/400 Amps, complete all as specified and as directed.

4

-

-

... More
Supply only fuse base with carrier for VCB 11000 Volts, 630/400 Amps, complete all as specified and as directed.

3

-

-

... More
Supply only test service switch for VCB 11000 Volts, 630/400 Amps, complete all as specified and as directed.

3

-

-

... More
Supply only safe high voltage tape roll (HT Tape) length 25 RM, complete all as specified and directed.

10

-

-

... More
Supply only plug & sockect 32 pin for VCB 11000 Volt, of 630/400 Amps, complete all as specified and as directed.

3

-

-

... More
Supply only Breaker jaw contacts (isolating) 630 Amp set of 06 Nos for VCB 11000 Volt complete all as specified and as directed.

2

-

-

... More
Supply only HRC fuse of anmy capacity for VCB panel complete all as specified and directed.

20

-

-

... More
Supply and fixing earth continuity galvanised iron strip of size 25x3mm complete all as specified and directed.

60

-

-

... More
M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground (earth pit not less than 2.5 m deep below ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to galvanised iron earth strip 32x6mm by means of bolts, nuts, checknuts and washers of galvanised iron or steel, GI earth strip protected by 40mm bore light grade GI pipe and other end connected to earthing test point or main switch board as directed including funnel with watering pipe of 20mm bore light grade GI, wire mesh, charcoal or coke and common salt in alternate layer of 15cm compacted thickness all around the earth electrode including PCC earth pit chamber of internal dimension (300x300x300) mm and having wall thickness 100 mm using PCC 1:2:4 type B1 alongwith RCC 1:2:4 type B1 precast cover 50 mm thick reinforced with 8 mm TMT bars both way @100mm c/c including one lifting handle including necessary plastering and excavation and earth work and refilling of black soil good conductor of earth and necessary testing shown in elctrical sketch No. 3 of MES SSR Part-I 2009 and dismantling of old one complete all as specified and directed. Note : (i) Main earth lead beyond 7.5 meter shall measured and paid saperatly. (ii) The whole earthing will be redone on quoted rate if the result found not satisfactorily and the decesion of Engineer-in-charge will be final and bound, No extra cost will be paid to the contractor for rectification of the earthing.

20

-

-

... More
M & L for PCC earth pit chamber of internal dimension (300x300x300) mm and having wall thickness 100 mm using PCC 1:2:4 type B1 alongwith RCC 1:2:4 type B1 precast cover 50 mm thick reinforced with 8 mm TMT bars both way @100mm c/c including one lifting handle and dismantling of old one complete all as specified and directed.

35

-

-

... More
M&L for spreading and levelling evenly in layers not exc 15cm thickness, 40 mm graded crushed stone aggregated at 11KV sub station/ four or two pole structure, complete all as specified directed.

50

-

-

... More
Supply & fixing in repair alluminium lugs long barrel type suitable for 95 sq mm cable, complete all as specified and as directed.

100

-

-

... More
Supply & fixing in repair alluminium lugs long barrel type suitable for 120 sq mm cable, complete all as specified and as directed.

100

-

-

... More
Dismantling of Over head aluminium conductor steel reinforced, complete all as specifed and directed.

2.5

-

-

... More
Supply and fixing ACSR conductor (Ferret/Rabbit/ Mink) including straching on OH line including binding on insulators with aluminium binding wire including jumpers and jointing, complete all as specified and as directed.

1

-

-

... More
Dismantling of cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, complete all as specified and directed.

1.5

-

-

... More
M & L for cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of preparation of exposed surfaces, application of one coat of red oxide primer and thereafter 2 coats of alluminiuam paint, complete all as specified and directed.

1

-

-

... More
Dismantling of insulators any type , any size complete all as specified and directed.

89

-

-

... More
M&L polymer type single disc insulator assembly for tension with tension clamps for conductors,working pressure 11000 volts complete all as specified and directed

10

-

-

... More
Supply and fix Pin type, polymer type insulator including two galvanised iron washers and one galvanised iron nut, 150mm height, 150mm dia for 11000 volts grade, complete all as specified and directed.

20

-

-

... More
Repair/servicing of existing gang operated air break off load switch disconnecting the electric supply and decarbonized properly and function mechanisim device fixed to nut bolt and use petrolium jelly, proper jumpering with and replacement of all u/s items of the air break switch such as Post type Insulator, Male, Female link , tenson spring with copper belt, DO fuse unit, GO Rod, operating handle and GI Pipe etc complete all as specified and directed. Note :- (i) Cost of steel nuts, bolts and washers, petrolium jelly will be included in the quoted rate . No extra amount shall be paid to the contractor for the same. (ii) Other items like male link, Female link,spring with copper belt, DO fuse unit, GO rod, operating sandle GI pipe etc shall be measured and paid seperately on relevant items on shedule.

30

-

-

... More
Supply only Post type porceline insulator for current rating 400 amps suitable for existing GOD 11000 Volt grade as per sample at site complete all as specified and as directed.

45

-

-

... More
Supply only Post type polymer insulator for current rating 400 amps suitable for existing GOD 11000 Volt as per sample at site complete all as specified and as directed.

10

-

-

... More
Supply only HT tension spring assembly with barrided copper belt of current rating 400 Amps for existing GOD 11000 volts complete all as specified and as directed. Make - BHEL / Jaipuria/ Rashtriya/ MEI.

90

-

-

... More
Supply only Female contact or fixed contact heavy duty and high conductive metal complete capacity 400 Amp suitbale for 11 KV rated horizontal GOD as per existing model and size complete all as specifed and as directed. Make - BHEL / Jaipuria/ Rashtriya/ MEI

90

-

-

... More
Supply only Male contact or Moving contact heavy duty and high conductive metal complete capacity 400 Amp suitbale for 11 KV rated horizontal GOD as per existing model and size complete all as specifed and as directed. Make - BHEL / Jaipuria/ Rashtriya/ MEI.

90

-

-

... More
Supply only Fiber glass tube with metalic fittings both ends suitable for DO fuse 11KV complete all as specifed and as directed. Make - BHEL / Jaipuria/ Rashtriya/ MEI.

30

-

-

... More
Supply only mild steel jumper carrier suitable for 11 KV GOD, complete all as specifed and as directed. .

30

-

-

... More
Supply only back connector plate suitable for 11 KV GOD, complete all as specifed and as directed. .

30

-

-

... More
Supply only Tinned copper flexible jumper of capacity 200A/400A suitable for 11KV rated GOD. Make - BHEL / Jaipuria/ Rashtriya/ MEI

30

-

-

... More
Supply of GOD connecting rod size as per site requirement and suitable for 11000 volt GOD complete all as specifed and as directed.

10

-

-

... More
Supply and fixing in replacement of vertical type switch air break gang operated switch tripple pole mechanically operating mounted on insulator and steel frame with operating mechanism worked from ground level for current rating up to 200 Amps and working pressure of 11000 volts grade consisting of 4 insulator per pole with GI medium grade operating handle and locking arrangements fixed with down rod operating brackets, complete all as specified and as directed.

6

-

-

... More
All as per item No 110 but current rating 400 Amps

8

-

-

... More
Supply and fixing DO (Drop out) fuse unit porcelne type, double stack, channel type, 3 pole, 11 KV, channel mounted, complete all as specified and directed. Make - High tension switch gear Ltd / Jaipuria / SK industries / Pactil.

20

-

-

... More
Supply and fixing in repair of operating handle of the GOD complete with locking arrangement on both ON and OFF position, complete all as specified and as directed.

15

-

-

... More
M & L for fault detection in damaged UG cable by Govt approved agency and using digital cable fault detector machine with DC high voltage current injectng to damaged cable and find fault near or accurate of 2 mtr in various location at Bengdubi Mil Stn of any size and type of 11 KV rated UG cable including the following in quoted rate all as directed and specified by Engineer-in-Charge:- (i) excavation & earthwork in any type of stratra of size 4 x 2 x .60m to usually inspect / repair the damaged cable when and where required. (ii) Sand cushioning in trenches, supply and laying conncrete cable cover, class HV, type I, flat, size 300 mm x 180 mm x 40 mm laid flat in trenches over the cable. (iii) Repair the damaged cable through straight joint as per existing size and made functional. Note :- (i) The fault should be done within 24 Hrs of time frame after informed by Tephonically Msg or letter. Falling which 1000/- per hrs will be levied from the contractor as penalty. (iv) Joint kit shall be paid separately on realivant items of the schedule.

5

-

-

... More
S&F in repair, lightening arrester, non-linear metal oxide type, complete with and including all fittings, distribution class, discharge capacity 65 Kilo amps suitable for 11 KV, out door typeand also including necessary connection and fittings all as per IS-3070 Part-III and IEC 1994, complete all as specified and as directed. Make: High tension switch gear Ltd / Jaipuria / SK industries / Pactil.

6

-

-

... More
Taking out old unserviceable existing XLPE insulated, heavy duty electric cables with aluminium conductor 11000 volts grade any size/ any core including aluminium lugs, from the trenches /duct/ any other location, complete all as specified and as directed. Note:- Excavation/earth work shall be measured and paid for separately.

150

-

-

... More
Relaying of serviceable cable taking down from item No 103 of HT 11000 volt under ground system of size 95 Sqmm 3 core to 185 sqmm 3 core complete all as specified and directed. Note:- Excavatioin and earth work, sand cushioning, protection covers, protection pipes and jointing kits Iincluding jointing materials shall be measured and paid for separately.

150

-

-

... More
Supply, laying and testing cable XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured electric power cables (hevy duty) with aluminium conductor 11000 volts grade (Earthed) of size 95 sqmm 3 core in replacement of ACSR conductor, complete all as specified and directed. Note:- Excavatioin and earth work, sand cushioning, protection covers, protection pipes and jointing kits Iincluding jointing materials shall be measured and paid for separately.

350

-

-

... More
All as per Item ser No 118 but cable size 120 sq mm 3 Core all as specified and directed.

200

-

-

... More
M&L Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armourend aluminium conductor cable of size 95 sqmm including testing complete all as specified and as directed.

5

-

-

... More
All as per srl item No 120 here in before but 120 to 185 Sqmm 3 core.

2

-

-

... More
All as per srl item No 120 here in before but 240 to 300 Sqmm 3 core.

1

-

-

... More
M&L Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm including testing complete all as specified and as directed.

7

-

-

... More
All as per srl item No 123 here in before but 120 to 185 Sqmm 3 core.

4

-

-

... More
All as per srl item No 123 here in before but 240 to 300 Sqmm 3 core.

2

-

-

... More
Supply and fix cable jointing kit for 11 KV grade cable for straight through outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conductor cable of size 95 sqmm including testing complete all as specified and as directed.

8

-

-

... More
All as per srl item No 126 here in before but 120 to 185 Sqmm 3 core.

3

-

-

... More
All as per srl item No 126 here in before but 240 to 300 Sqmm 3 core.

2

-

-

... More
Excavating and relaying high tension cables loops near the poles , transformers, cutting the damages/burnt parts of cable and reconnecting its into positions complete with thimbles, nut bolts, sleaves all as specified and directed by Engineer-in-Charge.

21

-

-

... More
Excavation in trenches in soft loose soil including cutting road surfaces n.exc 1.5 mtr wide and n.exc. 1.5 mtr in depth for poles, stay, cable, pipe etc getting out complete all as specified and as directed.

234

-

-

... More
Returning, filling in, including spreading,leveling,watering and well ramming in layers each n.exc 25 cm thick in soft loose soil, complete all as specified and as directed.

155

-

-

... More
Removing excavated material n exc. 50mtr and depositing where directed at a level n exc. 1.5 mtr above,the starting point.

80

-

-

... More
Relaying of old serviceable cable covers as in cable protection all as specified and directed.

500

-

-

... More
Supply and laying un-reinforced precast conncrete cable cover, class HV, type I, flat, size 300 mm x 180 mm x 40 mm laid flat in trenches over the cable with the length of cable cover perpendicular to the direction of cable length, adjacent/abutting each other complete all as specified and directed by Engineer-in-Charge.

1333

-

-

... More
M&L for Sand cushioning trenches using fine sand to under ground cable, laid in two layers 8cm before laying the cable & 15cm after laying the cable complete all as specified.

52

-

-

... More
Boring/Drilling (horizontally) using ultrasound technique and necessary machine for passing pipe for protection of the cable at approx 1 metre depth in soil below existing road, pavement, hardstanding etc without damaging to the existing surfaces, getting out & disposal of spoil to a distance not exceeding 50 metre from the site of the work, complete all as specified and directed. Note :- Cost of pipes & cable not included in the scope of above item.

20

-

-

... More
M&L in replacennt of cable protection GI tubing light grade fixed long the pole/under road/along the wall of size 100mm bore with necessary clamps, complete all as specified and as directed.

10

-

-

... More
All as per Item ser No 137 but size 80mm all as per specified and directed.

10

-

-

... More
All as per item ser no 137 but size 25 mm dia GI pipe medium grade for GOD including locking arrangemet for operating the GOD all specfied & directed by Engr-in-charge.

40

-

-

... More
Material & labour for replacement of stay assembly complete comprising of 7/3.15 galvanised stranded stay wire of required length, fixed to pole with and including FI clamps 50 x 6 mm, bolt, nuts washers, GI stay rod 20 mm dia and 1800 mm long, stay bow 400 x14mm, GI steel plate 300x300x6mm, Disc type insulator, porcelain,vitreous 145mm high and 255mm dia ball and socket type, white, brown or green clearance hole 16mm including two coats of aluminium paint over a one coat of red oxide primer on exposed mild steel work all as shown in Electrical Plate No. 1 of SSR part - I 2009 on Page No 495 compelete all as specified and directed. (Note :- Earth work, PCC work, and Insulator measured and paid separately)

4

-

-

... More
M&L Loop type porcelain vitreaus white, brown or green insulator large size with overall dimension 90mmx140mm hole 52.5mm etc,complete all as specified and as directed.

4

-

-

... More
S& F in repair Galvanised stay strand, size 7/4 mm complete all as directed including taking down the old unserviceable stay wire, complete all as specified and directed by Engr-in-Charge.

1

-

-

... More
M&L for providing PCC (1:3:6) type C:2 using 40mm graded crushed stone aggreate as in foundation for pole/stay assembly foundation of poles etc. complete all as specified and as directed.

4

-

-

... More
M & L in replacement danger notice plate for HT pole of size 25 cm x 20 cm of 1.6 mm thick mild steel sheet viterious enamaled white with letter figur and conventional skull and bones "DANGER" 11000 Volts (Written in English, Bengali and Hindi) in signal red colour and fixed with MS clamps made of 25mm x 3mm MS flat Iron bolts nuts complete including two coat of aluminium paint over a coat of red oxide primer complete all as specified and directed.

50

-

-

... More
M&L for Repair/servicing of Float cum Boost SCR controlled 110Volt. 30+30amp Three phase Dual battery charger cum DCDB any make and replace the all un servicable parts such as Diode, Contactor,complete all as specified and as directed. Note :- (i) Cost of spare parts not paid separately. (ii) Transformer and mother board of battery Charger measured and paid separately.

2

-

-

... More
Supply only diode 30A/130 Volt DC for Float/Booster battery charger, complete all as specified and as directed.

2

-

-

... More
Supply only AC contactor for Float/Booster battery charger complete all as specified and as directed.

2

-

-

... More
Supply only DC contactor for Float/Booster battery charger complete all as specified and as directed.

2

-

-

... More
Supply only DC capacitor for Float/Booster battery charger complete all as specified and as directed.

2

-

-

... More
Re-streching of existing ACSR conductor of any size any type as required sag fixed on OH line & insulators/cross Arms on poles properly binding on insulator with alumminum conductor. Note :- (i) Weight of ACSR or all aluminium conductor drawn for OH lines is to be measured by measuring tap horizontal distance between centres of two addacent poles and compounding the weight of conductor of that size and length and 3 % extra added for sag, jointing, jumpers and binding etc.

6

-

-

... More
Labour for cutting the tree branches passing near the HT OH line of width/ girth not more than 30 cm upto 3 meter distance from adjacent pole/OH line or four/two pole struction all as specified and directed by EIC.(From one pole to another pole is measured as one span and if multiple nos of branches within one span is measured as one unit) Note ;- (i) Each span having 35 to 60 mtr distance approximately. (ii) All cutting branches of trees shall be thrown away /burnt at approximately 200 to 500 mtr away from site. (iii) Transport to be provided by contractor to thrown away the branches, Cost of Tpt is included is quoted rate. (iv) Pruning the branches as and when required shall be carried out within three days after intimated telephonically msg or by letter to the contractor.

50

-

-

... More
M&L for precast reinforced cement concrete (1:2:4) type B-1 (using 20mm graded crushed stone aggrgate) route indicator of size 150x150x900mm with 8 mm dia steel einforcement @ 100 c/c both ways duly engraved " HT CABLE/HT JOINT /FEEDER NO " with two coats synthetic enamel paint (RED) first quality fixd with PCC (1:3:6) type C-1 (using 20mm graded crushed stone aggrgate) below ground level of size 30x30x300mm complete all as specified and directed. Note:- Quoted unit rate is deemed to be included the necessary cost of PCC, painting, writing, excavation, returning filling and removal etc.

58

-

-

... More
Supply and fixing in replacement PVC First aid box of size 30 cmx30cmx20cm including necessary first aid material/medicine i.e burn cream, bandage, cotton, detol, pain killer tablet of 10 Nos, Scissor, banded-10 Nos and all as specified and directed by Engineer -in-charge.

5

-

-

... More
Supply and fixing of information/safety instruction board duly fabricated with flexo sheet of high grade quality and writing/printing of information/picture/drawing/layout plan over flexo sheet duly structure framed with square iron bar of suitable size and fixed with suitable screws/paste including dismantling of old unsv information board complete all as specified and directed by Engr-in-charge.

18

-

-

... More
Material and labour for cleaning away all grass vegetation, scaling shrubs bushes under growth roots and trees not exceeding 30cm girth and removing rubbish four times during the contract period (interval between each of the cleaning of the sub stn shall not exceed 45 days ) Sub stations, VCB 's , LT Panel, transformer, Ht Poles, under over head lines complete all as specified and as directed. Note : After completion of four time of cleaning of the said area qty shall be considered one unit of this item for payment.

6700

-

-

... More
Material and labour for preparation of old rusted steel surfaces of (11m height) pole with cross arms, clamp of any length and shape of HT overhead line with one coat of aluminium paint including including marking pole numbers in a 20 cm dia black circle with white colour numbering with synthetic enamelled paint and strip marking of 3 Nos black synthetic enamelled & 02 Nos yellow bands width 30 cm by fluorescent yellow synthetic enamelled paint in alternate layers upto 1.5 mtr height above the P.C.C coping complete all as specified and directed.

125

-

-

... More
Material and labour for preparation of old rusted steel surfaces of HT 2 pole structure (11m length) pole with cross arms, clamp of any length and shape of HT overhead line with one coat of aluminium paint including including marking pole numbers in a 20 cm dia black circle with white colour numbering with synthetic enamelled paint and strip marking of 3 Nos black synthetic enamelled & 02 Nos yellow bands width 30 cm by fluorescent yellow synthetic enamelled paint in alternate layers upto 1.5 mtr height above the P.C.C coping complete all as specified and directed.

30

-

-

... More
Material and labour for preparation of old rusted steel surfaces of HT 4 pole structure (11m length) pole with cross arms, clamp of any length and shape of HT overhead line with one coat of aluminium paint including including marking pole numbers in a 20 cm dia black circle with white colour numbering with synthetic enamelled paint and strip marking of 3 Nos black synthetic enamelled & 02 Nos yellow bands width 30 cm by fluorescent yellow synthetic enamelled paint in alternate layers upto 1.5 mtr height above the P.C.C coping complete all as specified and directed.

20

-

-

... More
M&L for carrying out the Periodical Check and preventive maintenance/servicing of HT RMU (Ring Main unit) 11 KV, 630A/400A as per existing make alongwith tripping system and mechanism and carried out the fwg repair/tests made for smooth operation.: (a) Cleaning and greasing of mechanism. (b)Tightning testing of mechanism parts. (c ) Alignment testing and adjustment of mechanism.(d) Operation, testing of trip and close by electrical and manual mode. (e) Spring charging testing by electrical and manual mode.(f) Cleaning of panel insulator CT &PT unit of the panel. (g) Cleaning and tightning of control/wiring CT &PT unit.(h) Cleaning and testing of relay with current injection method (j) Testing of auxillary rela.(k) Allingment of trolley, checking/greasing of shutter /lock of breaker.(l) Testing of polarities of CTs.(m)Checking and recording of IR Values of VCB trolley and Panel. (n) Settings and coordination of relays. (o) Checking/repairing/rectification of the control wiring (r) Replacement of unserviceable ring type CTs. (s) Replacement of unserviceable Relay, Push botton, Indicator light HRC fuse etc. (t) High voltage testing with high voltage tester of CT & Breaker Pole to withstand working pressure of HT 11 KV to ascertain serviceability. (u) Testing the leakage of SF6 gas of the RMU. (v) Complete servicing, overhauling and testing of 11 KV indoor VCB Panel (including for Breakers) shall be got done by the contractor from the authorised agency as approved by the GE Note: (i) Any part/spare found defective during testing shall be repaired/replaced for which payment shall be made separately against respective items here in after except for minor parts such as packing, nuts bolts, cotton waste etc for which cost shall be deemed to be included in the unit rate quoted for this item. (ii) After completion of two time of servicing of each panel considered one Job of this item.Contractor shall deposit / Procure all the material in advance to avoid any late night fault/ after market hours / non availability of material in market. The electric supply shall be restore within 12 hours from the time of tripping / fault in day or night in the stn, failing this a panelty of Rs 5000/- per complaint / fault will be imposed on the contractor from contractor dues.

2

-

-

... More
Supply and fixing inreplacement of HT ACSR jumper with XLPE insulated PVC Sheathed 70 sq mm single core Aluminium unarmoured of 11000 Volts grade cable on HT overhead line and on HT two or four pole structure from top disc insulator to GOD and disc to disc in any length including stainless steel nuts, bolts, washers & long barrel thimbles all as required at site in complete all as specified and directed.

100

-

-

... More
Note: Schedule of cedit (Sch 'A') amount of Rs 273488.00 shall be deducted from the total quoted amount of BOQ.

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.