Military Engineer Services Tender

Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.

Military Engineer Services - MES Tender

Works
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date24 Dec 2024
Closing Date15 Jan 2025
Tender Amount₹ 46,30,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply, lowering, assembling and fixing in position 200 mm dia Fibre glass pipe, LCG Strainer cage type V wire wound screen having slot size 0.5 to 0.75 mm, confirming to ISI-8110-2000, IS-4270-2001 and composition of material as per ISI-1012, complete all as specified and directed.

40

-

-

... More
Supplying and fixing in position M/F Adapter of size 300x200mm complete all as specified and directed.

1

-

-

... More
Supply and fixing Bail plug, made out of PVC, of 200 mm dia with 7 mm wall thickness including fixing material complete all as specified and directed.

1

-

-

... More
Supply and fixing PVC reducer 300mm/ 200mm of wall thickness 7 mm, of suitable length to be fitted with 200 mm dia with 7 mm wall thickness including fixing material complete all as specified and directed.

1

-

-

... More
S&F in position mild steel well cap of MS plate 8 mm thick with an internal threading and locking arrangement having opening for column pipe and submersible cable of 300 mm dia internal housing PVC pipe and centre guide bail plug, reducing socket and and necessary welding work as required at site for completion of the job complete all as specified and directed. (Note- (i) Rate quoted is deemed to be included for necessary MS work required to be fixed well cap in position as directed at site by Engr-in-charge. (ii) After completion of the work the cap will be used to keep the tube well closed until the pump set is installed).

1

-

-

... More
Yield testing for the tube well by suitable capacity submersible pump & motor for minimum discharging capacity of 10000 gallons per hours for at least continuous 16 hours uninterrupted run per day complete all as specified and directed. (Note- (i) 'V' Notch and other equipment including pump set shall be arranged by the contractor as his own cost. (ii) Electricity will be supplied by the department for yield testing free of cost)

1

-

-

... More
Development of tube well according to clause 9.3 of IS-2800-1991 :(part-I) as amended upto date and specifications attached with air compressor of capacity 350 PSI/ 1000 Cum till sand/ mud free water of potable quality is obtained and to achieve minimum discharging capacity of 10000 GPH complete all as specified and directed. (Note- Compressor with accessories and fuel, pipes etc shall be arranged by the Contractor and quoted rate is deemed to be included in item)

72

-

-

... More
Testing of raw and treated water ( 02 samples @ Raw and treated water ) for all parameters covering complete Chemical and Bacteriological aspect from any Govt accredited/ NABL certified lab as approved by the GE complete all as specified and directed.

2

-

-

... More
Electrologing test (Geophysical) using suitable equipments for the bore hole before sinking/ lowering of pipes, filters etc for arresting proper deliniation of water from Govt recognized agency/ Govt firm and report shall be submitted to GE/ Engineer-in-Charge for approval complete all as specified and directed. (Note- (i) Procurement action of borewell items like submersible pump and motor, submersible cable, column pipe and other misc accessories required to be installed and borewell shall only be considered after submission of Electrologing Test report to GE/EIC and further instruction from the department shall be finaland binding).

1

-

-

... More
Supply and filling pea gravel of size 2 to 4 mm, for packing around the housing/ assembly, slotted pipe of the bore well, complete all as specified and directed. (Note- Pea gravel shall be paid as per stack measurement carried out on site).

25

-

-

... More
Supplying, lowering, fixing, commissioning and testing submersible pumping set with pump and motor in borewell electrically driven, 20HP, 415 Volts, three phase, AC, having a discharge capacity 55 Cum/Hour at a head of 80 metres, 8 stage, delivery/ discharge dia 100 mm including insertion of GI/ ERW column pipe with other connected accessories and necessary electrical connections complete all as specified and directed. (Note- GI column pipe, pipe accessories and submersible cable shall be measured and paid seperately).

1

-

-

... More
Supplying, lowering, fixing, commissioning and testing submersible pumping set with pump and motor in borewell electrically driven, 12.5 HP, 415 Volts, three phase, AC, having a discharge capacity 55 Cum/ Hour at a head of 60 metres, 8 stage, delivery/ discharge dia 100 mm including insertion of GI/ ERW column pipe with other connected accessories and necessary electrical connections complete all as specified and directed. (Note- GI column pipe, pipe accessories and submersible cable shall be measured and paid seperately).

1

-

-

... More
M & L for steel wire rope 8 mm galvanised IWRC as per IS-2262/02 alongwith suitable size clamps & 'U' bolts for holding the submersible pumps and motor of capcity upto 35 HP complete all as specified and directed.

40

-

-

... More
S & F Housing clamp 90 cm long made out of MS flat iron 100mm x10mm for 200mm dia casing pipe with neccesaary nut bolts full threads with nuts and washers at GL incl. painting complete all as specified and directed.

30

-

-

... More
Supply and laying PVC insulated and PVC sheathed industrial cable for Submersible pump motors of size 6 Sqmm flat three core copper conductor, 1100 Volts, Confirming to IS-694 complete all as specified and directed.

55

-

-

... More
Supply, laying and testing of ductile iron pipes (blue/ black colour) of size 150mm bore with spigot and socket ends, push on rubber joint, centrifugally cast, class K-9, in any length, laid in trenches/ on surface/ over masonary pillar and connection to old or new position including push on rubber (EPDM) ring complete all as specified and directed. (Note: (i) Rubber ring/ gasket joint, jointing materials, etc required for jointing of DI pipes shall deemed to be included in unit rate.(ii) Excavation and earth work shall be measured and paid separately).

45

-

-

... More
M&L for 150 mm bore DI pipe (specials) fitting for flanged pipe such bend (any type radius and angle) taper any type, (straight bends, increasing, decreasing or double socket etc.) complete all as specified and directed.

180

-

-

... More
Construction of valve pit chamber with brick masonary with sub class 'B' bricks (one brick thick) in cement mortar (1:6) and necessary PCC (75mm thick) type D2 (1:4:8) as in foundation and 15mm thick plastering on brick work in cement mortar (1:4) including necessary earthwork etc having internal dimension 120cm x 120cm x 120cm and providing of 3mm thick MS sheet cover duly hinged on 40mm x 40mm x 6mm angle iron frame and embedded on top of chamber by minimum 4 Nos MS hold fast. Necessary locking arrangement shall be provided to the sheet cover for safety. The steel surfaces shall be painted with two coats black bituminous paint over a coat of anti corrosive red oxide primer including demolition of old unserviceable valve pit chamber complete all as specified and directed.

1

-

-

... More
M&L for cutting in position of 150mm pipe, inserting new tee of (150x150x150) mm and jointing including with necessary jointing materials complete all as specified and directed.

1

-

-

... More
Supply, installing, testing and commissioning factory made and tested LT Outdoor type (Double door),( SIZE - 1200MMx1000MMx500MM,( HxWxD) platform mounted, suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system having bus bar chamber with insulated electrolytic Aluminium bus bars of 250 Amps rating installed on DMC insulators with bus bar chamber. The panel shall be dust and vermin proof, protection class (IP-65) and made of 3.00 mm thick CRCA mild steel sheet and mild steel angle iron frame work (made out of 50 mm x 50 mm x 6 mm thick), front opening type with aprons for cable entry, with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FRLS cable of adequate size but not less than 1.5 sqmm complete. All steel metal works including frame shall be with anticorrosive coating with seven stage process and finally epoxy polyester powder coating of flint grey shade. The scope of work also comprising of the following:- . BUS BAR CHAMBER:- (a) 200 Amp TPN, Alu. conductor,Supported on insulated plate form,interconnection of all incomings & outgoings. INSTRUMENT CHAMBER:- (i) Volt Meter, 96mm, flush type rated 0-500V, Digital type with Volt Meter selector switch- 01 Set. (ii) Amp Meter, 96mm, flush type rated 0-100A, Digital type with suitable size C.T's and Amp Selector switch- 01 Set (iii) RYB Phase indicating light LED type- 01 Set. INCOMING:- (i) MCCB 4 pole ,415 V, of rating 100 Amp 25 KA- 1 No. (ii) Change Over switch 100 Amps SS enclouser , 4 Pole- 01 No OUTGOING:- (i) FASD Starter suitable for 30 HP Rating submersible motor and pump - 02 Nos ( 01x running & 01xstand by), (ii) MCB 32A, DP, -02 Nos.(iii)MCCB 63Amps-02Nos. NOTE : Panel wiring for control circuit with copper flexible 1.5 Sq mm & power wiring minimum 4 Sqmm flexible.

1

-

-

... More
M&L for boring holes horizontally under road without damaging the surface of road (minimum 1.0m below the road surfaces) with the help of GI tubing of any dia not exceeding 100mm dia for passing of UG cable complete all as specified and directed.

6

-

-

... More
M&L for broken bricks for hardcore of gauge exceeding 63mm but not exceeding 100mm deposited spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface complete all as specified and directed.

3

-

-

... More
M&L for PCC (1:2:4) type B1 (using 20 mm graded stone aggregate) as in proper borewell sealing to prevent migration of surface water into the intake aquifer and neat cement grout near the top of the well with PCC sanitary sealing complete all as specified and directed.

1

-

-

... More
M & L for cement sealing with PCC (1:2:4) Type B-0, (using 12.5 mm graded crushed stone aggregate) for fresh water aquifers effective of 3 metre thickness on the borewell within the depth range 70 to 100 metres immediately above the top aquifer against the pure impermeable zone within the depth range of top aquifer (sand) zone tapped by slotted pipe and given rest for 72 hrs, for prevention of entering contaminated ground water to the borewell complete all as specified and directed. (Note- This item of schedule shall be executed in presence of EIC/JE incharge so that proper cement sealing would be ensured by the department executives and Contractor shall be fully responsible for Non adherance of the guideline and any damage/ contamination of ground water reported in later stage from the well penal recovery shall be recovered/ imposed on the Contractor).

1

-

-

... More
M & L for provision of a tripod stand over the borewell for lifting/ lowering of submersible pumpset & column pipes & made from 100 mm bore heavy grade GI tubing with flanged legs embedded in PCC foundation with (1:3:6) type C-2 mass concrete (using 40mm graded stone aggregates), each leg at 8 mtr distance from borewell & the vertex/peak of the stand should be at a height of 5 mtr above the edge of casing pipe & fastened together with 16 mm steel bar/ long bolts including necessary drilling, bending turning, welding work including painting to rustable surface including provn of one heavy duty chain pulley 5 ton capacity with chain and protective hood over the tripod stand complete all as specified and directed.

1

-

-

... More
M&L for PCC (1:3:6) type C-2 (using 40 mm graded crushed stone aggregate) as in foundation filling and mass concrete complete all as specified and directed.

2

-

-

... More
M&L for sand cushioning to under ground cable in trenches/existing cable trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep including required watering and consolidation after laying and stretching the cable complete all as specified and directed. (Note: Only punned down thickness of sand to be measured)

2.5

-

-

... More
M&L for brick covering with width equal to length of brick as protection to cable with well burnt sub class ‘B’ bricks of size 250mm x 125mm x 75mm laid dry flat complete all as specified and directed.

0.5

-

-

... More
S&F GI pipe 50mm dia (light grade) complete with all fittings in trenches, road/ culvert crossing, floors, on roof, on pole for cable protection complete all as specified and directed.

12

-

-

... More
Excavation in trenches soft/ loose soil not exceeding 1.5 mtr wide, not exceeding 1.5mtr in depth for foundation etc or for shaft well, cesspits, manholes, fire hole etc n.exc 10sqmm on plan and not exceeding 1.5mtr in depth and getting out complete all as specified and as directed.

15

-

-

... More
Returning, filling in trenches with excavated soil including spreading, levelling, watering and well ramming in layers not exceeding 25 cm complete all as specified and directed.

9

-

-

... More
Removing surplus soil /spoil to a distance not exceeding 50 metre away and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and directed.

6

-

-

... More
S&F XLPE insulated, LT armoured electric cable with aluminium stranded conductor 1100 volts grade, cross-sectional area 50 sqmm, 3.5 core laid in trenches/pipes/ducts/wall/borings with necessary cable lugs and glands, nuts, bolts and washers etc and testing complete all as specified and directed. (NOTE: Excavation/earth work, sand cushioning, cable cover/brick shall be measured and paid separately if required)

70

-

-

... More
M&L for earthing with glavanised steel earth plate electrode of size 60cmX60cmX6mm thick buried directly in ground (earth pit not less than 2.25 m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to the galvanised earth lead by means of bolts, nuts, check nuts and washers with galvanised iron strips of size 32 x 6 as earthing lead as shown in electrical plate No.3 of SSR Part-I connected to earthing test point all specified or indicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC (1:3:6) type C-1 using 20mm graded stone aggregate pit, funnel, 20mm dia GI medium grade watering pipe , 40mm dia GI medium grade earth lead protection pipe and pre-cast earth pit cover 50mm thick made of RCC (1:1.5:3) type A-1 duly reinforced with 8mm dia TMT bar @150c/c both ways, one lifting handle made out of 10mm dia TMT bar 250 mm long embedded in cover slab and cover, wire, copper lugs etc mesh, charcoal and common salt in alternate layer of 15 cm thick including taking down old unserviceable earthing complete all as specified and directed. (Note: Galvanised iron strip of size 32x6mm upto 7.5m long including testing is deemed to be included with quoted rate).

1

-

-

... More
Supply and laying ERW MS pipe, Heavy duty with welded GI flange (For Column pipe, 3 Meter Long, both side MS flange, 100 mm dia, ISI marked with all tube fittings complete with all fittings required for column pipe lowering like suitable size nuts, bolts and heavy duty washers and including cutting pipes, screwing, wash and for making gorged bends on piping complete all as specified and directed. (Note- Necessary nuts, bolts, washers and rubber washer/sheet required for jointing of column pipe every after 3 metre length is deemed to be included in quoted rate).

30

-

-

... More
S&F of Double Flanged non rising/Rising Spindle Sluice Valve 150 MM of PN 1.6, as per IS 14846 and IS1538, cast iron as per IS-210 Gr FG260, SS spindle, Bronze body seat ring, Bornze wedge ring, gland packing-jute & hemp, Natural rubber gasket, Bronze stem nut with spining wheel complete all as specified and directed.

1

-

-

... More
S&F of Non return sulice valve 150 mm bore confirming to IS-5312 Part-I, pressure rating PN1.6, Flange drilling as per IS-1538, CI valve body diaphragm, CI disc, Disc face ring -rubber, Aluminium hinge pin, CI hinge and bornze body ring complete all as specified and directed.

1

-

-

... More
Supply and install hi wall split AC units indoor/ outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with 5 star rating and EER 3.2 of 1.5 TR , complete installation including making holes, copper tube, wall bracket for indoor and outdoor unit and other accessories required for fixing of units are quoted in this unit rate complete all as specified and directed. Make : LG/ Voltas/ Carrier/ Daikin / Hitachi / Panasonic/ Haier/ Lloyd

9

-

-

... More
S & F submain wiring in PVC casing caping/PVC conduit with two runs of FRLSH PVC insulated 4.0 sq mm mutistranded copper conductor and 1 run of 4.0 sqmm FRLSH PVC insulated 1100 volts grade mutistranded copper conductor wire for continous earthing complete all as specified and directed. Note: Three runs of 4.0 sqmm PVC FRLSH cable alongwith one run of PVC casing capping/ PVC conduit shall be measured as a unit run.

90

-

-

... More
S&F Motor starter 25 amp with on off Push type switch, modular type two module complete all as specified and directed. Make Legrand Cat no 6792 72 or Equivalent as specified in PS here-in-after.

12

-

-

... More
S & F Socket 25 amp ,modular type two module complete all as specified and directed. Make Legrand Cat no 5734 66 or Equivalent

12

-

-

... More
S & F Cover plate with metal frames ,modular type two module complete all as specified and directed. Make Legrand Cat no 5757 10 or Equivalent as specified in PS here-in-after.

24

-

-

... More
S & F Metal flush box , modular type Two module complete all as specified and directed. Make Legrand Cat no 6890 07 or Equivalent as specified in PS here-in-after.

24

-

-

... More
Supply and fix refrigerator, electric driven (single phase), capacity upto 185 Litres BEE 5 star rated complete all as specified and directed. Make LG Model no D201ABHU or Equivalent in Samsung and IFB

1

-

-

... More
Supply and fix refrigerator, electric driven (single phase), capacity 224 Litres BEE 5 star rated complete all as specified and directed. Make LG Model NoD241ASAU or Equivalent in Samsung and IFB

1

-

-

... More
Supply and fix refrigerator, electric driven (single phase), capacity 322 Litres BEE 5 star rated complete all as specified and directed. Make LG Model No S322SPZY or Equivalent in Samsung and IFB

1

-

-

... More
Supply, installation, commissioning of Water cooler fully stainless steel, electric driven single phase having 150 ltr storage and nominal cooling capacity 150 ltr complete all as specified and directed. Make : Voltas / Blue Star / Usha

1

-

-

... More
Supply, installation, commissioning of Water cooler fully stainless steel, electric driven single phase having 60 ltr storage and nominal cooling capacity 120 ltr complete all as specified and directed. Make : Voltas / Blue Star / Usha

2

-

-

... More
Supply, installation, commissioning of Water cooler fully stainless steel, electric driven single phase having 40 ltr storage and nominal cooling capacity 80 ltr complete all as specified and directed. Make : Voltas / Blue Star / Usha

1

-

-

... More
Removing Existing Split type AC/ Water cooler/ Refrigerator from site and shifting to MES store of any capacity complete all as specifed and directed.

16

-

-

... More
Supply and fix voltage stabilizer for automatic operation single phase naturally air cooled indoor type & designed for input variation between 150-285 volt with output voltage stabilizer at 230 volt with accuracy of ( +/ -) 2.5% of Capacity 5 KVA. Make V Guard VND 500/ Equivalent in Microtek

9

-

-

... More
M&L for cutting chases, pinning in. making good to facings where required and pointing in cement mortar (1:3) to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc. and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth complete all as specified and directed.

10

-

-

... More
Supply, installation , commissioning of water cooler partially stainless steel, electrically driven single phase having approximate storage and nominal cooling capacity of 40 / 80 litres complete all as specified and directed. Make : Voltas / Blue Star / Usha

2

-

-

... More
M&L for 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC frame as required complete all as specified and directed.

535.5

-

-

... More
M&L for solid PVC wall lining consisting of 5 mm thick colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame complete all as specified and directed.

153

-

-

... More
S&F fancy type drapery curtain rod brackets complete all as specified and directed.

20

-

-

... More
S&F brass chromium plated curtain rods of 20mm dia complete all as specified and directed.

30

-

-

... More
Taking out old unserviceable floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and as directed

30

-

-

... More
Material and labour for rendering 15mm thick in cement mortar (1:6) on fair faces of brickwork or concrete surfaces, finished the surfaces even and smooth without using extra cement complete all as specified and directed.

30

-

-

... More
M&L for applying 1.5mm thick wall care putty on wall surface complete all as specified and directed.

30

-

-

... More
M&L for preparation of newly plastered surface of wall and applying two coats of distemper oil emulsion over a coat of alkali resistant primer complete all as specified and directed.

30

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.