Military Engineer Services Tender

Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.

Military Engineer Services - MES Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date17 Jan 2025
Closing Date8 Feb 2025
Tender Amount₹ 23,85,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply only integral water proofing compond, all as specified and directed.

3

-

-

... More
M&L for preparation of new plastered or unplastered surface of wall and applying two coats of distemper oil emulsion (OBD), over a coat of priming coat (Chalk whiting, on plastered surfaces, prepara-tory to distempering), complete all as specified and directed.

240

-

-

... More
M&L for 2mm thick wall care putty on wall, complete all as specified and directed.

240

-

-

... More
M&L for preparation of new plastered or unplastered surface of wall and applying two coats of exterior weather coat paint (exterior grade) over a coat of alkali resistance primer, complete all as specified and directed.

770

-

-

... More
M&L for preparation of new plastered or unplastered surface of wall and finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm), complete all as specified and directed.

70

-

-

... More
M&L for preparation of old plastered or unplastered surface of walls and applying one coat of distemper oil emulsion (OBD), over a coat of priming coat (Chalk whiting, on plastered surfaces, preparatory to distempering) including 1mm thick wall care putty on wall, complete all as specified and directed.

300

-

-

... More
Demolition of brickwork or stone / boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles, complete all as specified and directed.

0.4

-

-

... More
M&L for brickwork with fly ash bricks (old size bricks), straight or curved on plan exc 6m mean radius, built in cement mortar(1:6), complete all as specified and directed.

1.65

-

-

... More
Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings, complete all as specified and directed.

673

-

-

... More
S&F of pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, all as specified and directed.

650

-

-

... More
S&F of pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, all as specified and directed.

23

-

-

... More
Demolition of cement concrete (unreinforced) in ground floor and pavings not exc 15 cm thickness (below or above ground level), complete all as specified and directed.

5.63

-

-

... More
M&L for hardcore using broken stone or boulders of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface, complete all as specified and directed.

35.5

-

-

... More
M&L for sand filling under floors or in foundations including watering and consolidation, complete all as specified and directed.

28.4

-

-

... More
M&L for 75mm thick plain cement concrete (1:4:8), type D2 (using 40mm graded stone aggregate) as in sub-base, sub-floors, floors, pavings etc., all as specified and as directed.

355

-

-

... More
M&L for 40mm thick plain cement concrete(1:2:4), type B-1, (using 20mm graded stone aggregate) as in sub-base, sub-floors, floors, pavings, roof treatment etc., finish cement concrete surface even and smooth using cement extra cement, complete all as specified and directed.

355

-

-

... More
Supply only glass dividing strips, 3 mm thick and 38mm wide, all as specified and directed.

130

-

-

... More
M&L for 75 mm thick plain cement concrete(1:3:6), type C-2 (40 mm graded stone aggregate) as in plinth protection, hard standing, path etc. including finish the surface even and smooth without using extra cement, complete all as specified and directed.

75

-

-

... More
M&L for 25mm thick plain cement concrete(1:2:4), type B-0, (using 12.5mm graded stone aggregate) as in sub-base, sub-floors, floors, pavings, roof treatment, gutter surface etc.including finish the surface even and smooth with using extra cement, complete all as specified and directed.

25

-

-

... More
Taking down chowkhats or frames exc 1.5 sq. m but n exc 4 sq. m each with shutters (without taking off shutters from the frame), complete all as specified and directed.

32

-

-

... More
S&F of anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc., complete all as specified and directed.

65

-

-

... More
S&F of 4.8mm thick sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane, complete all as specified and directed.

60

-

-

... More
S&F of mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165, complete all as specified and directed.

20

-

-

... More
M&L for preparation of old steel surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint, complete all as specified and directed.

200

-

-

... More
Dismantling boarding, any description, fixed in any position with nails, complete all as specified and directed.

365

-

-

... More
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc., complete all as specified and directed.

42

-

-

... More
Taking down DB's including MCB's etc., complete all as specified and directed.

3

-

-

... More
Taking down carefully unserviceable sub main wiring of any size/core/type including making good the disturbed surfaces, all as specified and directed.

166

-

-

... More
Material and labour for point wiring with 1.5 Sqmm (nominal area) PVC insulated un-sheathed single core multi stranded copper conductor FRLSH cable 1100 volts grade (conforming to IS) drawn through and including rigid non metallic PVC casing and capping of required size (not less than 20mm) conforming to IS 2079-1973, medium grade with all necessary fittings, surface wiring for one light point or one fan point or one bell point controlled by one switch, with 1.5 Sq mm PVC insulated and unsheathed copper conductor for earth continuity conductor and making good disturbed surfaces to match with the existing surface roof/wall/floor, complete all as specified and directed including testing on completion.

24

-

-

... More
Material and labour for point wiring with 1.5 Sqmm (nominal area) PVC insulated un-sheathed single core multi stranded copper conductor FRLSH cable 1100 volts grade (conforming to IS) drawn through and including rigid non metallic PVC casing and capping of required size (not less than 20mm) conforming to IS 2079-1973, medium grade with all necessary fittings, surface wiring for one 3 pin socket outlet, 5 Amps on independent board, with 1.5 Sq mm PVC insulated and unsheathed copper conductor for earth continuity conductor and making good disturbed surfaces to match with the existing surface roof/wall/floor, complete all as specified and directed including testing on completion.

6

-

-

... More
Material and labour for point wiring with 1.5 Sqmm (nominal area) PVC insulated un-sheathed single core multi stranded copper conductor FRLSH cable 1100 volts grade (conforming to IS) drawn through and including rigid non metallic PVC casing and capping of required size (not less than 20mm) conforming to IS 2079-1973, medium grade with all necessary fittings, surface wiring for one 3 pin socket outlet, 5 Amps on the same board with other switches, with 1.5 Sq mm PVC insulated and unsheathed copper conductor for earth continuity conductor and making good disturbed surfaces to match with the existing surface roof/wall/floor, complete all as specified and directed including testing on completion.

4

-

-

... More
Material and labour for point wiring with 2.5 Sqmm (nominal area) PVC insulated un-sheathed single core multi stranded copper conductor FRLSH cable 1100 volts grade (conforming to IS) drawn through and including rigid non metallic PVC casing and capping of required size (not less than 25mm) conforming to IS 2079-1973, medium grade with all necessary fittings, surface wiring for one 6 pin socket outlet, 15 Amps on independent board, with 2.5 Sq mm PVC insulated and unsheathed copper conductor for earth continuity conductor and making good disturbed surfaces to match with the existing surface roof/wall/floor, complete all as specified and directed including testing on completion.

8

-

-

... More
S&F of switch piano, flush type single pole, one way, 5 Amps / 6 Amp, 240 Volts, all as specified and directed.

34

-

-

... More
M&L for ceiling rose, 3 phase/PVC/ polycarbonate, isolated body, three terminal, 240 Volts, all as specified and directed.

24

-

-

... More
M&L for socket outlet 2 in 1, 3 pin, 5 Amps / 6 Amps flush type, 240 Volts, all as specified and directed.

4

-

-

... More
M&L for switch socket combination 2 in 1, 5 Amps / 6 Amps flush type, 240 Volts, all as specified and directed.

6

-

-

... More
M&L for switch socket combination 3 pin 6 Amp / 16 Amp, 5 in 1, flush type, 240 Volts, all as specified and directed.

8

-

-

... More
Supply and fixing in repair of wall mounted LED tube lights fitting 1x 20W, 6500K including making connections with 2 core flexible copper wire 0.50 sq mm from ceiling rose after fixing fitting in position at site on 02 Nos new round blocks, complete all as specified and directed. Make Havells Cat Part No. ENDURALINEARPROBS20WLED865SPCSSIND or equivalent model as approved by Engineer-in-Charge and GE of makes as per Tender Document.

24

-

-

... More
Supply and fixing in repair of environmental friendly 70W LED ENDURA WELL GLASS NEO- IP66 energy saving long life corrosion resistant, vertical surface mounting pressure die-cast aluminium housing )light engine) well glass luminaries with high power LED, complete all as specified and directed.

12

-

-

... More
S&F of sub main wiring with two single core 4.0 Sqmm PVC (FRLSH) copper conductor, insulated multistranded unsheathed cable medium grade including PVC conduit concealed of required size (not less than 32mm) with accessories for sub main connection including 4.0 Sqmm FRLSH insulated multistranded unsheathed copper conductor used as a earth wire to common earth and connection to earth dolly, all as specified and directed. (Note :- Three runs of 4.0 sqmm PVC FRLSH copper conductor shall be measured as one unit length).

56

-

-

... More
S&F of sub main wiring with two single core 2.5 Sqmm PVC (FRLSH) copper conductor, insulated multistranded unsheathed cable medium grade including PVC conduit concealed of required size (not less than 32mm) conforming to IS 2079-1973 with accessories for sub main connection including 2.5 Sqmm PVC (FRLSH) insulated multistranded unsheathed copper conductor used as a earth wire to common earth and connection to earth dolly all as specified and directed. (Note:- Three runs of 2.5 sqmm PVC FRLSH copper conductor shall be measured as one unit length).

110

-

-

... More
SupSupply and fixing of sheet metal enclosure, double door for MCB DB's, 8 way single pole & neutral (SPN) and current carrying capacity of 200 amps rated bus bar suitable for 240 Volt, AC, 50Hz, complete all as specified and directed.

3

-

-

... More
Supply and fixing of 240V, 10KA 'C' curve miniature circuit breaker (MCB) of single pole & neutral (SPN) and current carrying capacity of 5 to 32 Amps in the MCB DB complete with connection testing and commissioning, all as specified and directed.

3

-

-

... More
Supply and fixing of 240V, 10KA 'C' curve miniature circuit breaker (MCB) of single pole (SP) and current carrying capacity of 5 To 32 AMP in the MCB DB complete with connection testing and commissioning, all as specified and directed.

18

-

-

... More
Note 1:- (Applicable for all parts/items) : The bidders/contractors are advised to read tender document, all drawings & all corrigendum / amendments and general condition of contracts before entry / quoting the rates. Note 2:-The contract sum shall be arrived at after deducting amount of schedule of credit from the total quoted amount.

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.