Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.

Military Engineer Services - MES Tender

Works
Civil And Construction
Civil Works Others
Electrical and Electronics
Electrical Works
Eprocure
Opening Date29 Mar 2025
Closing Date21 Apr 2025
Tender Amount₹ 38,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
S & F 0.63mm thick galvanised, corrugated mild steel sheeting, with two corrugations side lap, fixed with coach screws and washers, on roofs, walls etc. with grade of zinc coating 275, complete all as specified and as directed.

100

-

-

... More
S & F 1.00mm thick plain, galvanised mild steel sheeting, in ridges, hips, valley gutters, drip and eaves/straight flashings (length and girth as fixed) with grade of zinc coating 275, complete all as specified and as directed.

200

-

-

... More
Re-fixing only CGI sheet of any thickness fixed with self tapping screws, complete all as specified and as directed. (Note : Serviceable CGI sheet obtained from dismantling shall be re-used)

100

-

-

... More
Re-fixing only prepainted galvalume sheet of any thickness fixed with self tapping screws, complete all as specified and as directed. (Note : Serviceable galvalume sheet obtained from dismantling shall be re-used)

200

-

-

... More
M&L for preparing new zinc (or galvanised ) surfaces of CGI roof sheet of any description over 10cm width or grith, by applying mordant solution to receiving painting including washing and cleaning, etc. and applying two coats of synthetic enamel paint (1st grade quality) over a coat of red oxide primer, complete all as specified and directed.

314

-

-

... More
M&L for 4mm thick pre-painted E-fibre board, designer/decorative, fixed or laid/inserted to GI snap grid frame size 605 x 605mm work for false ceiling hangers with 4mm to 6mm dia. G.I. (length as required) adjusting level, fixed to roof slabs/truss by means of ceilling cleats made out of G.I. flat 40 x 3mm size 60mm long and expansion hold fasteners, 12.5mm dia, 40mm long including necessary dismentaling of existing unserviceable ceiling boards of any thickness including cover fillets, complete all as specified and directed.

250

-

-

... More
Demolition of un-reinforced cement concrete of any description not otherwise specifically provided for, complete all as specified and directed.

8.8

-

-

... More
M&L for PCC (1:2:4) type B1 (20mm grades crushed stone aggregates) as in coping, benching and similar works including weathering slightly rounded on chamfered angle and throating, complete all as specified and directed.

3

-

-

... More
Dismantling wrought iron or mild steel work of any description not otherwise provided for and removing from site of work, complete all as specified and directed.

15

-

-

... More
S&F roof trusses (framed), trussed,purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel ,rolled section or flat sections) of Fe-410W, Gde E-250 including distance pieces, cleats etc, complete all as specified and directed.

2000

-

-

... More
S&F MS framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe.290, Gde-E-165, complete all as specified and directed.

500

-

-

... More
M&L for preparation of new steel or iron surfaces of any description over 10cm width or girth and applying two coat of synthetic enamel paint (1st grade quality) over a coat of red oxide primer, complete all as specified and directed.

150

-

-

... More
M&L for preparation of old painted steel or iron surfaces and applying one coat of synthetic enamel paint (1st grade quality) any description over 10cm width or girth, complete all as specified and directed.

200

-

-

... More
M&L for preparation of new steel or iron surfaces of any description n. exc. 10cm width or girth not otherwise specifically described and applying two coat of synthetic enamel paint (1st grade quality) over a coat of red oxide primer, complete all as specified and directed.

15

-

-

... More
Taking down cement plaster on brick or concrete wall surface including racking out joints, hacking for key, scrubbing down with water, etc, compelete all as specified and directed.

15

-

-

... More
M&L 15mm thick rendering in CM (1:6) on fair faces of brick work or concrete surfaces of wall, finished even and smooth without using extra cement, complete all as specified and directed.

60

-

-

... More
M & L for rendering 15mm thick in two coats (10mm under layer + 5mm top layer) on fair faces of brick work or concrete surfaces of wall in CM (1:4), mixed with integral water proofing compound on top layer as per manufacturer's instructions and finished the surface even and fair without using extra cement, complete all as specified and directed. (Note : WPC shall be measured and paid separately)

110

-

-

... More
Supply only liquid water proofing compound conforming to IS: 2645 - 1975 specification, complete all as directed

2

-

-

... More
M&L for preparation of newly plastered surfaces of wall and applying two coats of cement base paint over a coat of alkali resistance primer, complete all as specified and directed.

110

-

-

... More
M&L for preparation of newly plastered or unplastered surfaces of walls and applying two coats of distemper oil emulsion over a coat of chalk whitening primer, complete all as specified and directed.

60

-

-

... More
Demolition of brick work or stone boulder masonry, built in cement mortar including all quoins, pillars etc., separation of serviceable materials from the unserviceable, stacking the serviceable materials within 100 m and disposal of unserviceable materials, debris and rubbish to a distance not exceeding 100m, complete all as specified and directed.

4

-

-

... More
M&L for brick work with sub class 'B' bricks, old size, burnt clay bricks, straight or curved on plan exc 6 mtr mean radius built in CM (1:4), complete all as specified and directed.

4

-

-

... More
M & L for cleaning the LT feeder piller box indoor/out door type of size up to 3.0m x 2.0m x 0.5m of different rating bus bar, after dismatling the incomming and out going connections from MCCB/bus bar including replacing the old unserviceble nut, bolts, supporting insulators etc and checking the servicebility of MCB/MCCB, earth continuity conductor, tightning the earth conductor, incomming and out going cables and removing existing old insulation of bus bar and MCCB/MCB terminals, providing new insulation tape of standard quality, applied to bus bar and MCCB terminals and cleaning the feeder piller box, complete all as specified and directed. Note : Contactor have to take the shut down of LT panel before starting the job and switch on the panel after completion of work.

40

-

-

... More
S&F in repair LT danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20 x 15cm size, complete all as specified and directed.

40

-

-

... More
S&F in repair copper earth strip of size 20 x 3mm laid in trench/ wall/ floor with necessary supporting insulators in regular interval as directed from earh test point to terninal point with double nut bolt joint at starting terminal, complete all as specified and directed.

34

-

-

... More
M&L for writing "Feeder Piller No.____" on feeder piller with synthetic enamel paint (1st garde quality), size of each letter 75mm x 75mm on and including black back ground surface, complete all as specified and directed.

60

-

-

... More
S & F in repair LED Indicating lamps for Main Supply indicating R', Y' B', complete all as specified and directed.

20

-

-

... More
S&F in repair digital analoge voltmeter 0-500 V, three phase phase of size 96mm x 96mm for existing pannel, including wiring bush bar to voltmeter, complete all as specified and directed.

8

-

-

... More
S&F in repair digital analoge ammeter range 10 Amp to 500 Amp three phase of size 96 mmx 96 mm for existing pannel, including wiring CT ratio -1/5, complete all as specified and directed.

8

-

-

... More
S & F in repair pre-casted LT cable rout marker made from RCC (1:2:4) (using 20mm graded crusded stone aggregate) reinforced with 10mm dia TMT bar, 3 Nos with length and 5 Nos. with width, size 1200mm x 300mm x 100mm, marked as "MES CABLE" and painted with two coats of synthetic enamel paint (yellow), complete all as specified and directed. Note : Excavation and earth work shall deemed to be included in the unit quoted rate.

14

-

-

... More
Supply, installing and commissioning of outdoor type bus bar panel box (size 900mm x 900mm x 450mm) made out of 3.15mm thick CRCA sheet, out door type, CPRI approved, totally enclosed weather, dust and vermin proof as per IS with front and rear , copper bus bar 400 Amp capacity for RYB and half for neutral and insulated with insulators, including connecting incoming and outgoing cables necessary made out of 50 x 50 x 6mm angle iron grouted at floor above 30cm from ground level including foundation with PCC (1:2:4) type B-1, of required size, including taking down old unserviceble box, complete all as specified and directed.

1

-

-

... More
Taking down, disconnecting & re- fixing XLPE/PVC cable passing through DWC pipe by saddling/clamping with suitable size of saddle on wall which already existed, in zig-zag way, complete all as specified and directed. Note- DWC pipe shall be measure and paid seperately.

300

-

-

... More
Supply and laying double walled corrugated (DWC) HDPE duct pipe of 40mm outer dia conforming to IS, approved colour, complete with fittings for cable protection, complete all as specified and directed.

240

-

-

... More
Supplying and laying synthetic rubber insulated mats 2mm thick for voltage upto 3.3 KV for electrical purpose as per IS 15652-2006, suitable for electrical shock safety, complete all as specified and directed.

22

-

-

... More
S&F in repair air termination rod, single pointed aluminium rod 12mm dia and 300mm long, complete all as specified and directed.

20

-

-

... More
S&F in repair air termination rod, single pointed copper rod 12mm dia and 300mm long, complete all as specified and directed.

10

-

-

... More
S&F MCB Triple Pole (TP) of capacity 40 to 63 Amps, 240 Volts, breaking capacity 10 KA, ‘C’ series, with overload and short circuit protection, fixed in proper position including connection and testing , complete all as specified and directed.

10

-

-

... More
S&F MCB Triple Pole and Neutral (TPN) of capacity 40 to 63 Amps, 415 Volts, breaking capacity 10 KA, ‘C’ series, with overload and short circuit protection, fixed in proper position including connection and testing , complete all as specified and directed.

12

-

-

... More
S&F MCB Single Pole and Neutral (SPN) of capacity 40 to 63 Amps, 240 Volts, breaking capacity 10 KA, ‘C’ series, with overload and short circuit protection, fixed in proper position including connection and testing , complete all as specified and directed.

12

-

-

... More
S & F in repair water proof junction box made from SMC/FRP sheet, ready made of size 140 x 140 x 95mm with aluminium bus bar of 50 Amp capacity for RYB and half for neutral made in suitable size fixed inside the junction box with necessary supporting insulators fixed on hylem sheet ,MS sheet steel fixed inside the bottom portion of box to connect the cable gland complete , entire assembly fixed to pole /Wall with MS clamp 25 X 5 mm and nuts & bolts, or inside the Copping of pole /Post top with necessary size copper lugs for connecting cables from junction box to fittings, complete all as specified and directed.

8

-

-

... More
S & F in repair water proof junction box made from SMC sheet ready made of size Junction box of size 350 x 270 x 210mm with aluminium bus bar of 150 Amp capacity for RYB and half for neutral made in suitable size fixed inside the junction box with necessary supporting insulators fixed on hylem sheet, MS sheet steel fixed inside the bottom portion of box to connect the cable gland complete, entire assembly fixed to pole/wall with MS clamp 25 X 5 mm and nuts & bolts, with necessary size copper lugs for connecting cables from junction box to fittings, complete all as specified and directed.

28

-

-

... More
S & F in repair water proof junction box made from SMC sheet ready made of size Junction box of size 400 x 300 x 190mm with aluminium bus bar of 200 Amp capacity for RYB and half for neutral made in suitable size fixed inside the junction box with necessary supporting insulators fixed on hylem sheet, MS sheet steel fixed inside the bottom portion of box to connect the cable gland complete, entire assembly fixed to pole/wall with MS clamp 25 X 5 mm and nuts & bolts, with necessary size copper lugs for connecting cables from junction box to fittings, complete all as specified and directed.

4

-

-

... More
Checking the earth resitance of existing copper/GI plate earthing by meggar and repair/replacement of strips where found corroded and testing of earth resistance value and providing magnesium sulphate and salt (minimum 8 kg per earthing) to achieve required earth resistance value, complete all as specified and directed. Note: Replacement of strip if required, shall be measured paid separately under relevant items. .

400

-

-

... More
M & L earthing complete with GI earth plate electrode 600mm x 600mm x 6mm thick burried directly in ground vertically to a depth not less than 2.25m below ground level with the top edge of earth plate at depth not less than 1.5m below ground level connected with galvanised earth strip of size 25 x 4mm dia by means of bolts, nuts, check nuts and washers protected by 40mm bore light grade GI pipe, funnel with 20mm bore GI medium grade pipe for watering, wire mesh, including concrete pit in PCC (1:3:6) type C-1, with 50mm thick pre-cast RCC (1:2:4) type B-1 in cover slab (reinforced with 8 mm dia deformed bar @ 15 cm C/C both ways and suitable handle of 10mm dia round bar), including providing charcoal or coke and common salt in alternate layers of 15cm compacted thickness all around the earth electrode, with funnel, wire mesh, aluminium lugs, complete in all respect and other end connected with main switch board or earthing test point as directed, including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessary testing on completion including taking down old one, complete all as specified and directed. Notes : Proper earthing pit should be provided with pit cover.

15

-

-

... More
M & L for construction PCC earthing pit with cover for existing earthing, concrete pit in PCC (1:3:6) type C-1, pre cast RCC (1:2:4), type B1 in cover slab, size 400 x 400 x 50mm with one handle for lifting made out of 8mm dia TMT bar, 15cm center to center both direction and 10mm dia MS handle suitable size includind, necesary earth work in soft/loose soil all as shown in electrical plate No 4 of MES schedule Part -I and applying two coats of white wash on exposed surfaces of concrete and testing inclduing demolition of old earth pit, complete all as specified and directed.

80

-

-

... More
S&F in repair aluminium strip 25 x 3mm with saddles and fixing screws etc. for roof conductors and down conductors above ground, complete all as specified and directed.

40

-

-

... More
S&F in repair GI wire 4mm dia with saddles and fixing screws etc. for roof conductors and down conductors above ground, complete all as specified and directed.

100

-

-

... More
M & L for mild steel chequired plates Fe-290 (Grade E-165), 5 mm or over in thickness conforming to IS1730-1961 as in duct covering placed over existing angle iron frame work or provision new frame work where necessary including connection of suitable number earth strip welded properly and making good to the existing surface of duct, complete all as specified and directed.

180

-

-

... More
M&L for preparing new steel or iron surfaces of panel board, over 10cm width or girth and applying two coats of synthetic enamel paint (1st grade quality) over a coat of red oxide primer, using spray painting machine, complete all as specified and directed.

60

-

-

... More
M&L steel tubular swaged pole, type 410 SP-31 (9.00 metres long) complete with cast iron base plate, finial taper plug, cap, mild steel bolts, nuts, screws, etc. including applying two coat of black bituminous paint internally and externally up to planting depth and applying with two coats of aluminium painting over a coat of red oxide primer including writing 'MES LT pole No.______' with synthetic enamel paint (1st grade quality), complete all as specified and as directed. Note : Earth work and PCC shall be measured and paid separately.

6

-

-

... More
M&L for painting PCC poles, 8.5 meter in height above GL including cross arms and bracings on existing surface after cleaning and removing dust, rust & dirt with one coat primer and two coat of Cement based paint painting with black & white alternate strips of 30cm each externally from ground level up to 1.5 mtr with synthetic enamel paint (1st grade quality) and numbering of pole, complete all as specified and as directed.

54

-

-

... More
M&L for painting steel tubular poles, 8.5 meter in height above GL including cross arms and bracings on existing surface after cleaning and removing dust, rust & dirt with one coat of redoxide primer and two coat of aluminium paint painting with black & white alternate strips of 30cm each externally from ground level up to 1.5 mtr with synthetic enamel paint (1st grade quality) and numbering of pole, complete all as specified and as directed.

280

-

-

... More
Excavation in trenches not exceeding 1.5m wide and exceeding 1.5m but n.exc. 3m deep for foundation, etc, n.exc. 10 Sqm on plan and getting out in soft/loose soil complete all as specified and directed.

3.6

-

-

... More
Removing excavated soils to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.

3.6

-

-

... More
M&L for PCC (1:4:8) type D-2 (using 40mm graded crushed stone aggregate) as in foundation, filing and mass concrete etc. including formwork (as required), complete all as specified and directed.

0.4

-

-

... More
M&L for PCC (1:3:6) type C-1 (using 20mm graded crushed stone aggregate) as in coping of poles, etc. including necessary formwork (as required), complete all as specified and directed.

3.1

-

-

... More
M&L for PCC (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) as in coping of poles, etc. including necessary formwork (as required), complete all as specified and directed.

5.8

-

-

... More
Uprooting grass/weeds/plants up to 30cm depth by scrapping soil in order to make free ground from all sort of vegetation (grass/weeds/plants) and hand packing carefully by packing round pebbles approximately of size 20 to 40mm after carefully picking form heap of pebbles/stones, complete all as specified and directed.

3950

-

-

... More
Cleaning of area around E/M sub division by scraping the grass and creepers from roof and spraying grass killing chemical with spray gun, as per manufacturer's instructions for prevention of weeds and grass at surrounding of E/M sub station area, complete all as specified and directed.

2000

-

-

... More
Note: An amount of Rs.92,296.00 on account of Credit Schedule for schedule 'A' part - II shall be deducted from the total amount of BOQ to arrive at the contract sum.

-

-

-

... More
Supply and fixing energy efficient ‘LED Flood Light 120 W LED luminaire with Aluminium dia cast housing, toughened glass cover with IP 66 protection, CCT 5700 K including fixing arrangment on wall/pole / surface and connecting cable up to nearest ceilign rose into flexible PVC conduit. Make : Crompton/Havells/ Surya/Philips

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.