Military Engineer Services Tender
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.
Military Engineer Services - MES Tender
Civil And Construction
Building Construction
Eprocure
Opening Date8 Oct 2024
Closing Date5 Nov 2024
Tender Amount₹ 24,08,000
Costs
EMD
₹ 48,160Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_678690_1Bid Award Id
ViewTender No
8965/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Dismantling of asbestos cement (corrugated, semi-corrugated etc.) sheets in roof coverings complete all as specified and directed.
850
-
-
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
38
-
-
S&F of pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet of 0.50mm thick of any colour as approved by GE having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
800
-
-
S&F of pre-painted galvalume aluminium zinc coating GI based plain steel sheet of 0.50mm thick of any colour as approved by GE having tensile strength of 550 Mpa as in ridge / wall/cladding, fixed with self tapping screws complete all as specified and directed.
50
-
-
S&F of false ceiling with exposed metal (PPGI) framework/ “Tee” Grid providing and fixing of suspended Tee grid false ceiling using “T” Grid System – powder coated GI (PPGI) exposed grid false ceiling suspension system in grid size 600mm x 600mm with main runner 32 x 24mm x 0.3mm thick, cross tee 26mm x 24mm x 0.3mm thick and wall angle 24mm x 24mm x 0.40mm thick using 4mm thick non asbestos fibre cement board of size 595 x 595mm, an asbestos Free fibre cement board manufacture using high Pressure System Curing technology. T grid Framing is suspended using 4mm GI/MS bar hanger fixed with steel dash fasteners or iron purlin from the roof with adjustment clip, also providing provisions for light fixtures, air conditioning diffusers and ducts, sprinklers, smoke detectors etc. The main runners to be secured to structural soffit by hanger @ 1220mm maximum c/c. The last hanger at the end of each main runner should not be placed at not more that 300mm from the adjacent wall. 1220mm/600mm Cross Tee to be interlocked between main runners @ 600mm c/c, so as to from 600mm x 600mm or 1200mm x 600mm grid, confirming IS 14862 & type B category III of ISO 8336, tested as per AS 1530 part – 3 & B. S- 476 part 4,5,6,7 & 8 should be placed in Grid module to form complete all as specified and directed.
500
-
-
S&F of rolled mild steel angle iron roof trusses (framed) and purlins, rafters crane gantries, rails, heavy brackets etc including distance pieces, cleats, angle, tee etc including necessary cutting , welding etc complete Fe-410W (Gde E-250) quality 'A' complete all as specified and directed.
1000
-
-
M&L for non skid (joint free) ceramic coloured tiles of 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc set and jointed in neat cement slurry and pointed with white cement mixed with pigment to match with shed of tiles over and including 15mm thick screed bed or beading layer of cement mortar (1:4) for laying floor finishes complete all as specified and directed.
30
-
-
Ditto-all as per Item No.10.00 here-in-before but in skirting/dado over and including a backing coat of 10mm thick cement plaster in cement mortar (1:3) complete all as specified and directed.
8
-
-
M&L for rendering 15mm thick in cement mortar (1:6) on brick work or concrete surfaces of wall, finished even and smooth without using extra cement complete all as specified and directed.
300
-
-
M&L for applying two coats of oil emulsion distemper over a coat of alkaline resistant primer over 3mm thick white wall care putty after preparation of newly plastered surfaces of wall complete all as specified and directed.
300
-
-
M&L for applying two coats of oil emulsion distemper over a coat of alkali resistant primer over and including applying 3mm thick wall care putty on old decorated plastered surface of wall after and including complete removal of existing treatment and preparation of surfaces complete all as specified and directed.
100
-
-
PART - II : (E/M WORKS) :
Excavation in trenches for laying under ground cable, foundation and erection of poles and stays in soft/loose soil not exceeding 1.5 meter wide and not exceeding 1.5 meter deep and getting out complete all as specified and directed.
6.3
-
-
Returning, filling in, including spreading leveling, watering and well ramming in layers not exceeding 25cm soil all as specified and directed.
3.42
-
-
Removing surplus excavated materials to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting points in soft/loose soil complete all as specified and directed.
2.88
-
-
Supply and laying of XLPE insulated, LT armoured electric cable with aluminium stranded conductor 1100 volts grade, cross-sectional area 10 sqmm, 4 core laid in trenches/pipes/ducts/wall/borings with necessary cable lugs and glands, nuts, bolts and washers etc and testing including taking down old unserviceable cable complete all as specified and directed.
(NOTE: Excavation/earth work, sand cushioning, cable cover/brick shall be measured and paid separately if required)
40
-
-
M&L for brick covering with width equal to length of brick as protection to cable with well burnt sub class ‘B’ bricks of size 250mm x 125mm x 75mm laid dry flat complete all as specified and directed.
0.22
-
-
M&L for sand cushioning to under ground cable in trenches/existing cable trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep including required watering and consolidation after laying and stretching the cable complete all as specified and directed. (Note: Only punned down volume of sand to be measured)
2.27
-
-
Taking down carefully copper/aluminium point wiring (light, fan, bell, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, holders, regulators, sockets, light fittings and including making good the disturbed surfaces to match with the existing surfaces by applying white/ colour wash/distemper over applying of putty for smooth finish surface complete all as specified and directed.
186
-
-
M&L for point wiring complete with 1.5 sqmm PVC insulated, FR-LSH type, ISI marked, conforming to IS-694/1990 unsheathed, multistranded, single core, copper conductor cable 1100 volts grade colour code cables drawn through and including PVC Conduit 20 mm dia medium grade (MMS) and including cutting, chasing work at any height and all accessories concealed in walls / roofs / floors / ceiling etc. flush mounting MS box with top, bottom, side/back wall knockout for conduit entry from any direction made out of 1.60mm thick and 50mm depth suitable for fixing of modular top cover , blanking plate as per numbers of switch modules, modular switches, sockets, fan regulators, red colour indicator, blank plates etc as approved coloures modular accessories of suitable modules and including 1.5 Sqmm PVC insulated multistranded FR-LSH type unsheathed single core cable with copper conductor cable as earth continuity conductor and connecting to common earth dolly and including making good the disturbed surfaces to match with existing surfaces by applying white/colour wash/distemper as applicable after applying of putty for smooth finish surface complete all as specified and directed for the following:- (Note:- (i) All necessary accessories such as modular box, top cover plate, blank plate, screws, washers etc are to be used of same make/brand only in relevant items.
(ii) Cutting & chasing of wall for point wiring at any height shall be done and cost of the same deemed to be including with quoted rate.)
-
-
-
One light point controlled by one switch .
90
-
-
One fan point controlled by one switch and one regulator.
34
-
-
One 5 pin 6 amps socket point controlled by one 6 amps switch on independent board .
33
-
-
One 5 pin 6 amps socket point controlled by one 6 amps switch on same board .
16
-
-
Ditto- all as per Item No.22.00 here-in-before but point wiring with 2.5sqmm PVC insulated multistranded flexible unsheathed copper conductor FR-LSH and earth conductor of size 2.50 sqmm complete all as specified and directed for the following :-
-
-
-
One 6 pin 6/16 amps socket outlet point controlled by one 16 amps switch on independent board.
10
-
-
One 6 pin 6/16 amps socket outlet point controlled by one 16 amps switch on same board.
3
-
-
S&F of modular switch 10 Amps, single pole, 1 way, 1 module, 240V, AC, complete all as specified and directed.
173
-
-
S&F of modular socket 6 Amps, 2/3 pin combined shutter socket, 2 module with light indication, 240 V, AC, complete all as specified and directed.
49
-
-
S&F of modular socket 6/16 Amps, 6 pin combined shutter socket, 2 module with light indication, 240 V, AC, complete all as specified and directed.
13
-
-
S&F of modular fan regulator, electronic, 360 degree rotation (0 to 4), 100 to 120 Watts, 2 module, 240Volts, AC, complete all as specified and directed.
34
-
-
S&F of modular switch 16 Amps, single pole, 1 way, 1 module, 240V, AC, complete all as specified and directed.
13
-
-
S&F of ceiling rose , three terminal, PVC/polycarbonate body, complete all as specified and directed.
124
-
-
S&F of decorative box type 20 -22watt LED fittings with and including LED T-8 tube light 20 watt of fire retardant engineering grade complete with all accessories internally pre-wired, connecting up with and including three core sheathed flexible copper conductor cable of required size and including mounted on PVC/Wooden round/square blocks-02 Nos including taking down old unserviceble fittings complete all as specified and directed.
(Make : Philips Cat No. TMC501T8 and MAS LED tube PC body/ Crompto Greeves Cat No. IGP 118 T8 and LT8-20865-2/ Surya Cat No. SUB 118 T8 & SLETLDS 20 PC or equivalent model/Cat No of make as per Appx 'A' as mentioned in PS here-in-after)
82
-
-
S&F of powder coated sheet metal enclosure 415 volts AC,TPN distribution board 4 way suitable for flush mounting with 100 Amps copper busbar, neutral bar, earth bar and MCB incomer of rating upto 100 Amps, MCB TPN/DP, and MCB SP as outgoing and complete connecting cable links with top and bottom removable gland plate with IP 43 DBs protection and including making good the disturbed surfaces to match with existing surface and colour coat including taking down old unserviceable DBs complete all as specified and as directed.
(Make:- Legrand cat No. 5076 80 4 way /L&T Cat No. DBTPN004GD/C&S Cat No. CSDBTPNHPCGDD04 or equivalent model/Cat No of make as per Appx 'A' as mentioned in PS here-in-after)
2
-
-
S&F of powder coated sheet metal enclosure 240 volts AC, SPN distribution board 12 way for flush mounting with 200 Amps copper busbar, neutral bar, earth bar and MCB incomer of rating upto 200Amps, MCB SPN/DP and MCB SP as outgoing and complete connecting cable links with top and bottom removable gland plate with IP 43 DBs protection and including making good the disturbed surfaces to match with existing surface & colour coat including taking down old unserviceable DBs complete all as specified and directed.
(Make: Legrand cat No. 5076 22 12 way /L&T Cat No. DBSPN012GD/C&S Cat No. CSDBSPNCGDD12 or equivalent model/Cat No of make as per Appx 'A' as mentioned in PS here-in-after)
2
-
-
S&F of MCB, TPN, four pole, 100 Amps, 'C' Series, 415 Volts, 50Hz, complete all as specified and directed.
2
-
-
S&F of MCB, SP, 6 Amps to 32 Amps , 'C' series, 240 Volt, 10KA, 50 Hz, complete all as specified and directed
20
-
-
S&F of MCB, SPN, 40 Amps to 63 Amps , 'C' series, 240 Volt, 10KA, 50 Hz, complete all as specified and directed
5
-
-
M&L for sub main wiring complete with 2 run of 4 sqmm single core copper conductor (ISI marked) cable 1100 volts grade, FR-LSH type, PVC insulated, unsheathed, flexible, multi stranded colour coded cables drawn through and including rigid PVC conduit of required size medium grade (MMS) with all connected accessories such as Bend, Tee, Elbow, Short pieces etc concealed in wall/roofs/floors and including one run of 4 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, FR-LSH type as earth continuity conductor connected to common earth dolly and including chease cutting and filling the same with cement mortar and finished with putty and making good the disturbed surfaces to match with existing surface as required for concealed work including taking down old unserviceable submain wiring complete all as specified and directed .
216
-
-
M&L for sub main wiring complete with 2 run of 6 sqmm single core copper conductor (ISI marked) cable 1100 volts grade, FR-LSH type, PVC insulated, unsheathed, flexible, multi stranded colour coded cables drawn through and including rigid PVC conduit of required size medium grade (MMS) with all connected accessories such as Bend, Tee, Elbow, Short pieces etc concealed in wall/roofs/floors and including one run of 6 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, FR-LSH type as earth continuity conductor connected to common earth dolly and including chease cutting and filling the same with cement mortar and finished with putty and making good the disturbed surfaces to match with existing surface as required for concealed work including taking down old unserviceable submain wiring complete all as specified and directed .
55
-
-
M&L for sub main wiring complete with 2 run of 10 sqmm single core copper conductor (ISI marked) cable 1100 volts grade, FR-LSH type, PVC insulated, unsheathed, flexible, multi stranded colour coded cables drawn through and including rigid PVC conduit of required size medium grade (MMS) with all connected accessories such as Bend, Tee, Elbow, Short pieces etc concealed in wall/roofs/floors and including one run of 10 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, FR-LSH type as earth continuity conductor connected to common earth dolly and including chease cutting and filling the same with cement mortar and finished with putty and making good the disturbed surfaces to match with existing surface as required for concealed work including taking down old unserviceable submain wiring complete all as specified and directed .
(Note for item No. 36 to 38 : (i)Two runs of cable with one run earth wire and PVC conduit shall be measured as one length. (ii) Extra length of cable required for connection to DBs shall be deemed to be included in the unit rate and shall not be measured separately. (iii) Earth wire shall run inside the conduit. (iv) Suitable color code of wire must be ensured for phase/netural/earth. (iv) All surface cutting/making good for wiring/switch board/junction box/DB etc are included with unit quoted rate.)
40
-
-
M&L for earthing with glavanised steel earth plate electrode of size 600mmX600mmX6mm thick buried directly in ground (earth pit not less than 2.25 m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to the galvanised earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel using GI or steel wire 4mm dia as earthing lead as shown in electrical plate No.3 of SSR Part-I connected to earthing test point all specified or indicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC (1:3:6) type C-1 using 20mm graded stone aggregate pit, funnel, 20mm dia GI medium grade watering pipe , 15mm dia GI medium grade earth lead protection pipe and pre-cast earth pit cover 50mm thick made of RCC (1:1.5:3) type A-1 duly reinforced with 8mm dia TMT bar @150c/c both ways, one lifting handle made out of 10mm dia TMT bar 250 mm long embedded in cover slab and cover, wire, copper lugs etc mesh, charcoal and common salt in alternate layer of 15 cm thick including taking down old earthing complete all as specified and directed.
(Notre: Galvanised iron wire of 4mm dia upto 7.5m long including testing is deemed to be included with quoted rate).
2
-
-
Supply, fabricated and fixing of street light bracket made out of GI pipe 32mm dia medium grade bent to shape of 1.2 mtr long as directed including clamps made out of 30 mm x 6 mm thick -02 Nos flat iron for fixing bracket suitable for PCC/steel tubular poles/on wall surfaces including nuts and bolts, washers and other connected items of required size including painting with two coats of aluminium paint over a coat of red oxide primer including taking down old unserviceable brackets complete all as specified and directed.
8
-
-
S&F of 35/36 watt LED street light fittings IP-65/66 pressure die cast housing LED lamp aluminium compact high power LED street light with heat resistant toughened glass with LED lamp, inbuilt 4KV surge protector and necessary connection with suitable size copper cable including taking down old unserviceable light fittings complete all as specified and directed . (Make :- SURYA CAT NO-SLE UL 36WIP66LXN / HAVELLS CAT NO. ENDURASUNDOWN SL 35W LED 765PASYBOPC / PHILIPS CAT NO. BRPO46LED36CWMRSLPSUGRor equivalent model/Cat No of make as per Appx ‘A’ as mentioned in PS here-in-after)
8
-
-
M&L for 40mm bore GI pipe (Medium Grade) in any length including embedded in wall two ends duly welded MS hold fast at two ends of GI pipe and providing PCC in wall and making good disturb surfaces including taking down old unserviceable pipe complete all as specified and as directed.
24
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements