Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.

Military Engineer Services - MES Tender

Works
Civil And Construction
Civil Works Others
Electrical and Electronics
Electrical Works
Eprocure
Opening Date18 Dec 2024
Closing Date10 Jan 2025
Tender Amount₹ 31,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply and fixing sub main wiring with two run of single core 10 Sqmm PVC insulated unsheathed stranded cable copper conductor drawn through and including PVC conduit not less than 32mm dia with all fittings including one run of 10 sq mm PVC insulated unsheathed single core copper conductor as earth wire complete all as specified and as directed. Note : (i) Two run of single core cable 10 sq mm and one run earth wire 10 sq mm will be measured as one length.

150

-

-

... More
Taking down unserviceable rusted / damaged MCB TPN/ DBs of any type and way in the work and making good to the distubed surfaces of walls etc. complete all as specified and as directed.as per direction of engineer in charge.

48

-

-

... More
Supply and fixing sheet metal enclosure for DB's when MCBs to be used made up with sheet metal double door, phosphorised, power coated, neutral link, earth bar and din rail, 4 way single pole & neutral with 200 amps rated bus bar, 240 volts complete all as specified and as directed.

20

-

-

... More
Supply and fixing sheet metal enclosure for DB's when MCBs to be used 8 way single pole and neutral double door with 200 amps rated bus bar complete including connection all as specified.

15

-

-

... More
Supply and fixing sheet metal enclosure for DB's when MCBs to be used 12 way single pole and neutral, double door, with 200 amps rated bus bar complete including connection all as specified.

5

-

-

... More
Supply and fixing sheet metal enclosure for DBs when MCBs to be used, phosphorised, power coated, neutral link, earth bar and din rail, 4 way TPN double door with 200 amps rated bus bar, 240 volts complete all as specified and as directed.

4

-

-

... More
Supply and fixing sheet metal enclosure for DBs when MCBs to be used, phosphorised, power coated, neutral link, earth bar and din rail, 8 way TPN double door with 200 amps rated bus bar, 240 volts complete all as specified and as directed by Engineer in charge.

4

-

-

... More
Taking down unserviceable rusted / damaged MCB TP/SPN/SP of any type and way along with any type MCB and keeping serviceable MCB in safe custody in re-use in the work and making good to the distubed surfaces of walls etc. complete all as specified and as directed.

260

-

-

... More
Supply and fixing MCB 6 to 32 Amps, SP, 240 Volts ,B- Curve breaking capacity 10 KA complete all as specified and as directed by Engineer in charge.

50

-

-

... More
Supply and fix MCB 40 Amps, SP, 240 Volts , 'B' curve braking capacity 10 kA complete all as specified and as directed by Engineer in charge.

130

-

-

... More
Supply and fixing MCB 40 to 63 Amps, DP 240 Volts ,C- Curve breaking capacity 10 KA complete all as specified and as directed by Engineer in charge.

35

-

-

... More
Supply and fix in replacement MCB 6 to 32 Amps,SP, 240 Volts , 'C' curve breaking capacity 10 KA as directed by the Engr-in-Charge.

40

-

-

... More
Supply and fix in replacement MCB 40 to 63 Amps,DP, 240 Volts , 'C' curve breaking capacity 10 KA as directed by the Engr-in-Charge.

8

-

-

... More
Supply and fixing MCB TP 25 to 63 Amps, 415 Volts ,B- Curve breaking capacity 10 KA as directed by the Engr-in-Charge.

5

-

-

... More
Supply and fixing MCB TPN/FP 40 to 100 Amps, 415 Volts ,B- Curve breaking capacity 10 KA complete all as specified and as directed by Engineer in charge.

5

-

-

... More
Supply only Casing capping with 04 Nos accessories like tee bend elbow of high quality material size 12-20mm of 2m length complete all as specified and as directed by Engineer in charge.

100

-

-

... More
Supply only conduit pipe PVC high quality with 04 Nos accessories like tee bend elbow size 20mm, 10 feet long complete all as specified and as directed by Engineer in charge.

50

-

-

... More
Supply only accessories like wooden gutka, china clip,0.5 inch screw,1 inch screw, 2 inch screw etc. complete all as specified and as directed by Engineer in charge.

1000

-

-

... More
Supply only 1.5sqmm FRLSH flexible PVC insulated single core unsheathed industrial multistrand Copper conductor cables complete all as specified and as directed by Engineer in charge.

100

-

-

... More
Supply only 2.5sqmm FRLSH flexible PVC insulated single core unsheathed industrial multistrand Copper conductor cables complete all as specified and as directed by Engineer in charge.

100

-

-

... More
Supply only plug top 3pin16A 240V Easy to carry, Non flammable & Durable Heavy duty , nickel plated brass terminals Long lasting polycarbonate plastic material complete all as specified and as directed by Engineer in charge.

80

-

-

... More
S&F AC starter unit consisting of one 25 Amp capacity starter, one 240 V 25 Amps 10 KA SPN MCB, one 25 Amps socket and one 25 Amps plug top prewired including taking town of old unserviceable one complete all as specified and as directed by Engineer in charge.

5

-

-

... More
S&F plug and socket in sheet metal enclosures with two pin and earth plug and socket complete with and including MCB SP 20 Amps 240 volts heavy duty all as including taking down of old unserviceabe one specified and as directed by Engr-in-charge.

10

-

-

... More
M&L for earthing as per IS:3043 with galvanized steel earth plate electrode 600 mm x 600 mm x 6.0 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to galvanized strip 32 mm x 6 mm as earthing lead protected by GI pipe medium grade 15 mm bore for protection of GI earth wire and 20 mm dia GI pipe medium grade for watering with alternate layers of charcoal /coke and salt including all accessories like nut, bolts, reducer, nipple, wire meshed/screened funnel and making brick masonry finished chamber of internal size 300 mm x 300 mm x 300 mm with concrete base, covered with a Cast Iron hinged cover resting over the Cast Iron frame painted with bitumastic paint which shall be embedded in the block masonry including excavation works, refilling, connected to main switch/MCB DB for feeding the electric supply to domestic quarters complete all as specified and as shown in electrical plate No. 5 of SSR Part-I and testing of earth resistance as required complete all as specified and directed. as per direction of engineer in charge.

10

-

-

... More
Supply and fix in repair electronic meters temper proof LCD display with polycarbonate cover 230 V, 10- 60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH complete all as specified and as directed by Engineer in charge Note- Old Meters to be deposited in MES store.

2

-

-

... More
Supply and fix in repair electronic meters temper proof LCD display with polycarbonate cover 3phase 415V, 10- 60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH complete all as specified and as directed by Engineer in charge. Note- Old Meters to be deposited in MES store.

2

-

-

... More
Supply and fix MCCB 4 pole 630A, 50KA, 415V thermal and magnetic adjustable type including making all fixing arrangement, cutting welding of existing panel board as per site requirment and painting the disturbed part of panel as per the existing colour ofthe panel and electric connection complete all as directed including taking down old one complete all as specified and as directed by Engineer in charge.

1

-

-

... More
Supply and fix MCCB 3 pole 400A, 36KA, 415V thermal and magnetic adjustable type including making all fixing arrangement, cutting welding of existing panel board as per site requirment and painting the disturbed part of panel as per the existing colour ofthe panel and electric connection complete all as directed including taking down old one complete all as specified and as directed by Engineer in charge.

2

-

-

... More
Supply and fix MCCB 4 pole 350A, 36KA, 415V thermal and magnetic adjustable type including making all fixing arrangement, cutting welding of existing panel board as per site requirment and painting the disturbed part of panel as per the existing colour ofthe panel and electric connection complete all as directed including taking down old one complete all as specified and as directed by Engineer in charge.

1

-

-

... More
Supply and fix MCCB 4 pole 250A, 36KA, 415V thermal and magnetic adjustable type including making all fixing arrangement, cutting welding of existing panel board as per site requirment and painting the disturbed part of panel as per the existing colour ofthe panel and electric connection complete all as directed including taking down old one complete all as specified and as directed by Engineer in charge.

2

-

-

... More
Supply and fix MCCB 4 pole 200A, 36KA, 415V thermal and magnetic adjustable type including making all fixing arrangement, cutting welding of existing panel board as per site requirment and painting the disturbed part of panel as per the existing colour ofthe panel and electric connection complete all as directed including taking down old one complete all as specified and as directed by Engineer in charge.

1

-

-

... More
Supply and fix MCCB 4 pole 160A, 36KA, 415V thermal and magnetic adjustable type including making all fixing arrangement, cutting welding of existing panel board as per site requirment and painting the disturbed part of panel as per the existing colour ofthe panel and electric connection complete all as directed including taking down old one complete all as specified and as directed by Engineer in charge.

2

-

-

... More
Supply and fix MCCB 3 pole 100A, 25KA, 415V thermal and magnetic adjustable type including making all fixing arrangement, cutting welding of existing panel board as per site requirment and painting the disturbed part of panel as per the existing colour ofthe panel and electric connection complete all as directed including taking down old one complete all as specified and as directed by Engineer in charge.

3

-

-

... More
Supply and fix MCCB 3 pole 63A, 16KA, 415V thermal and magnetic adjustable type including making all fixing arrangement, cutting welding of existing panel board as per site requirment and painting the disturbed part of panel as per the existing colour ofthe panel and electric connection complete all as directed including taking down old one complete all as specified and as directed by Engineer in charge.

7

-

-

... More
Supply and fix MCCB 3 pole 32A, 16KA, 415V thermal and magnetic adjustable type including making all fixing arrangement, cutting welding of existing panel board as per site requirment and painting the disturbed part of panel as per the existing colour ofthe panel and electric connection complete all as directed including taking down old one complete all as specified and as directed by Engineer in charge.

2

-

-

... More
Supply and fixing 415V 10KA 'C' curve miniature circuit breaker (MCB) of 3 poles and 32A complete in APFC panel with all connection including taking down old one complete all as specified and as directed by Engineer in charge.

16

-

-

... More
Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of cables/foundation of poles and getting out in soft /loose soil complete all as specified and directed by Engr-in-Charge.

234.9

-

-

... More
Supply and laying dry coarse sand as in cushioning of under ground electric cable in trenches, laid to a uniform thickness of 23 Cm (15 Cm under the cable & 8 Cm over the cable) and gently punned down to 18 Cm thickness complete all as specified and as directed by the Engr-in-Charge. Note:- Thickness after punning down shall be measured for payment.

79.5

-

-

... More
Supply and laying in trenches, sub class 'B' over burnt (kiln burnt) old size bricks, laid flat dry with width of the bricks laid to the axis of the cable for protection of cable complete all as specified and as directed by the Engr-in-Charge.

2860

-

-

... More
Supply and laying in trenches except bricks obtained from taking out old unserviceable XLPE cable, laid flat dry with width of the bricks laid to the axis of the cable for protection of cable complete all as specified and as directed by the Engr-in-Charge. Note:- old serviceable bricks shall be obtained from taking down item.

5040

-

-

... More
Returning filling in including spreading levelling watering and well ramming in layers not exc 25cm complete all as specified and directed by the Engr-in-Charge.

98.67

-

-

... More
Removing excavated materiasl not exc 50 mtr and depositing where directed at a level next 1.5mtr above the starting point complete all as specified and direced by the Engr-in-Charge

94.8

-

-

... More
S & F DOL motor starter 3 phase for 0.75 to 7 HP including taking down old one complete all as specified and as directed by Engineer in charge.

2

-

-

... More
S & F Fully automatic star delta starters in sheet steel enclosure type MN/ ML for motor rating AC 3 Duty 415 V 50 Hz 3 Phase 17.5 HP including taking down old one complete all as specified and as directed by Engineer in charge.

1

-

-

... More
S & F Fully automatic star delta starters in sheet steel enclosure type MN/ ML for motor rating AC 3 Duty 415 V 50 Hz 3 Phase 30 HP including taking down old one complete all as specified and as directed by Engineer in charge.

1

-

-

... More
S & F Fully automatic star delta starters in sheet steel enclosure type MN/ ML for motor rating AC 3 Duty 415 V 50 Hz 3 Phase 75 HP including taking down old one complete all as specified and as directed by Engineer in charge.

1

-

-

... More
Taking out old U/S LT UG cable of any size and any description including GI pipe of any dia and bricks for cable protection where ever appeared and all as directed by Engineer-in-Charge. Note:- (i) Serviceable bricks obtained shall be stacked properly for re-use. (ii) Excavation and earth work shall be measured and paid separately.

1075

-

-

... More
Supply and laying XLPE insulated PVC sheathed, armoured, aluminium conductor cable 1100 Volt grade 185 Sqmm 3.5 core in trench/duct/floor/wall with provision of saddle and lugs, joints etc including connection complete all as directed by the Engr-in-Charge.

50

-

-

... More
All as per item No. 51.00 mentioned here-in-before 150 Sqmm 3.5 core

80

-

-

... More
All as per item No. 51.00 mentioned here-in-before but 150 sqmm 3.5 core

110

-

-

... More
All as per item No. 51.00 mentioned here-in-before but 120 sqmm 3.5 core

70

-

-

... More
All as per item No. 51.00 mentioned here-in-before but 95 Sqmm 3.5 core

110

-

-

... More
All as per item No. 51.00 mentioned here-in-before but 70 Sqmm 3.5 core

130

-

-

... More
All as per item No. 51.00 mentioned here-in-before but 50 Sqmm 3.5 core

110

-

-

... More
All as per item No. 51.00 mentioned here-in-before but 35 Sqmm 3.5 core

40

-

-

... More
All as per item No. 51.00 mentioned here-in-before but 25 Sqmm 3.5 core

125

-

-

... More
All as per item No. 51.00 mentioned here-in-before but 16 Sqm 2core

100

-

-

... More
All as per item No. 51.00 mentioned here-in-before but 16 Sqm 4 core

50

-

-

... More
All as per item No. 51.00 mentioned here-in-before but 10 Sqm 4 core

100

-

-

... More
All as per item No. 51.00 mentioned here-in-before but 10 Sqm 2 core

50

-

-

... More
S&F Straight through joint kit heat shrinkable 10 to 50 sqmm 4 core for LT 1100 Volts grade complete with jointing materials and accessories suitable for 3.5/4 core XLPE armoured conductor cable of following sizes including testing of cable after joints all as specified and directed.

2

-

-

... More
All as per item No. 64.00 mentioned here-in-before but 70 sqmm to 95 sqmm 3.5 core

2

-

-

... More
All as per item No. 64.00 mentioned here-in-before but 120 sqmm to 300sqmm 3.5 core

2

-

-

... More
Materials and labour for Cutting roads / hard standing to a depth not less than 45 cm and not less than 40 cm wide for laying of GI pipe to draw the UG cable and making good the disturbed surfaces by filling of PCC (1:3:6) type C-2 using 40 mm graded stone aggregate and finished the surface even and smooth with out using extra cement and disposed off the surplus debris and soil to a distance not exc 50 m complete all as specified and as directed by the Engr-in-Charge.

30

-

-

... More
M & L for 40mm bore GI tubes light grade for cable protection supporting to poles with all fixing accessoires (clamps, nut, bolt and washer etc) complete all as specified and directed.

30

-

-

... More
Taking down old aluminium strip/ GI strip of any size and refixing the same with new saddles ,clamps,screws etc to its original position and taking down existing unserviceable/worn out complete all as specified and as directed by engineer in charge.

400

-

-

... More
M&L for 32 x 6mm aluminium strip burried in ground/fixed on wall ,roofwith saddles and fixing screws etc., for roof conductors and down conductors above ground complete all as specified and as directed

400

-

-

... More
M&L for Air termination,single pointed Al rod 12mm dia and 300mm long complete all as specified and as directed

60

-

-

... More
M&L for Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm,drilled and screwed including 3nos 8mm dia 25mm long hex. Head screw and taking down existing unserviceable/worn out complete all as specified and as directed by engineer in charge.

60

-

-

... More
Supply & fixing Changeover Switch in sheet steel enclosure, four pole, 250 Amps, Manual type, 415 V after taking down old unserviceable onecomplete all as specified and as directed.

1

-

-

... More
Disconnecting the 0.5/1/2 HP unserviceable pump set for servicing , rewinding incl overhauling by replacement of bush bearing of motor/pump and refixing the same testing & commissioning complete all as directed by Engr-in-Charge.

1

-

-

... More
S & F 3 ph Voltmeter meter, digital type,50-520 VAC (P-P) voltage with in-built selector switch, complete with suitable size of CT's, size 96 x 96 mm complete all as specified and as directed by the Engr-in-Charge.

5

-

-

... More
S & F 3 ph Ammeter, digital type,0-500 Amps with in-built selector switch, complete with suitable size of CT's, size 96 x 96 mm complete all as specified and as directed by the Engr-in-Charge.

5

-

-

... More
S & F multifunction meters, digital type,50-520VAC (P-P) size 96 x 96 mm with dedicated buttons available for direct access to basic, power abd ebnergy parameters complete all as specified and as directed by the Engr-in-Charge.

2

-

-

... More
M&L for PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation base of poles and other similar locations including demoltion of old PCC/broken PCC complete all as specified and as directed by the Engr-in-Charge.

2

-

-

... More
M&L for PCC (1:3:6) type C-2 using 40mm graded stone aggregate with and including all necessary form work complete all as specified & directed.including demoltion of old PCC/broken PCC

0.2

-

-

... More
M&L for PCC (1:2:4) type B-1 using 20mm graded stone aggregate as in coping of pole/struts and other similar location etc with and including all necessary form workand plastering including demoltion of old PCC/broken PCC complete all as specified and as directed by the Engr-in-Charge.

0.5

-

-

... More
Supply and fix PVC cable terminal boxes, outdoor type of size 155mm x210mm x92mm with MCB SP 6 to 32 Amps including all necessary fittings and connection including taking down old unserviceable one complete all as directed by Enginner-in-Charge.

4

-

-

... More
Supply and fix PVC cable terminal boxes, outdoor type of size 93mm x93mm x62mm including fixing with clamp including taking down old unserviceable one complete all as directed by Enginner-in-Charge.

4

-

-

... More
Supply and fix PVC Pole boxes, outdoor type of size 195x135x90 mm IP 65 for pedestrin lighting including fixing with clamp including taking down old unserviceable one complete all as directed by Enginner-in-Charge.

5

-

-

... More
Supply and fix PVC Pole boxes, outdoor type of size 250 x 200 x 105mm for flood lighting IP 65 including fixing with clamp including taking down old unserviceable one complete all as directed by Enginner-in-Charge.

5

-

-

... More
Supply and fix Digital time switches 2 module 250 V single Phase of 20 Amp rating with contactor fitted inside steel enclosure including taking down old unserviceable one complete all as directed by Enginner-in-Charge.

2

-

-

... More
Taking out unserviceable street light of any type and any sizes from the site of work complete all as specified and directed.

40

-

-

... More
Supply and fix LED decorative post top lantern, 35/40 Watt capacity for energy efficient conservation upto 50% and with eco friendly lighting system with all accessories and necessary connection including taking down old unserviceable one complete all as specified and as directed.

4

-

-

... More
Supply and fix LED IP65 rated inverted Pyramid Tripod type, LED Bollard 10/8 Watt capacity with soft 360° light distribution with all accessories and necessary connection including taking down old unserviceable one complete all as specified and as directed.

4

-

-

... More
Supply and fix Pressure die cast powder coated housing with PC diffuser efficient high output LED with IP 66 protection LED bollard light cylindrical shaped 9/10 watt capacity IP 65 protection including necessary connection and taking down old unserviceable one complete all as specified and as directed.

7

-

-

... More
S & F LED 12 Watt IP 67 rating waterproof fountain light compact and robust design with aluminum housing, waterproof connectors with colour white/ RGB/ mono RGB with all accessories and necessary connection including taking down old unserviceable one complete all as specified and as directed.

2

-

-

... More
Supply and fix LED bollard light tulip shaped 9/10 watt capacity with opal acrylic IP 65 protection including necessary connection and taking down old unserviceable one complete all as specified and as directed.

10

-

-

... More
Supply and drawn into the steel tubular pole, by drilling holes just above the junction box and another holes near street light brackets including inserting PVC insulated stranded copper electric cable of size 2.5 sqmm 2 core & all necessary connetions with junction box and street light fittings, complete all as specified and as directed. Note:- Junction box and street light fittings shall be measured and paid saperately under relavent item of BOQ/ Sch 'A'.

200

-

-

... More
Materials and labour for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.00 mm thick burried in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to GI strip 32x6 mm as earthing lead by means of bolts, nuts, check nuts and washers of GI or steel, GI strip proected by 40 mm bore light grade GI pipe and other end connected to earth test point as directed including funnel with watering pipe 20 mm bore light grade galvanised iron, wire mesh, charcoal or coke common salt laid in alternative layer of 15 cm (complete thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1, 50 mm thick pre-cast RCC (1:2:4) type B-1 normal mix cover slab reinforced with 8 mm dia TMT bar 10 cm c/c bothways and single handle of 10 mm dia round bar including necessary excavation, earth work etc. in soft / loose soil and disposal pf soil to a distance n. exc. 50 m and necessary testing on completion all as shown in electrical plate No. 3 MES Schedule Part-I complete all as specified and as directed.Note-: Excavation to be measured and paid under sch item no- 1 above and PCC will be& paid under sch item no 10 above.contractor its following iteams have not been considered against items no-29 (i) funnel with watering pipe,wire mesh and copper lugs. (ii) GI protector pipe (iii) Test point

5

-

-

... More
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed.

10

-

-

... More
Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed.

10

-

-

... More
Supply and fixing LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed.

10

-

-

... More
Supply and fixing LED street light fitting 120 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed.

10

-

-

... More
Supply and fixing LED flood light 80watts 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant including taking down old unserviceable one complete all as specified and as directed.

5

-

-

... More
Supply and fixing LED flood light 50watts 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp including taking down old unserviceable one complete all as specified and as directed.

10

-

-

... More
Material and labour for repair of LT panels/LT feeder piller boxes by carrying out checking thoroughly all electrical connections, lugs busbar, voltmeter, ammeter ,cable glands ,insulator on busbar, and tightening all connections properly with proper size of new nut, bolt, washer as per the site requirements and insulation of busbar with colour code insulation tapes including welding on damage panel and preparation of surfaces internal and external of panels/feeder piller boxes by cleaning with dry cloth /removal dust particles by using air blower and scratching the old painted surfaces as directed and painting with two coats of synthetic enamel paint over a coat of red oxide primer and rewriting existing letters /numbers as directed and repair the existing PCC basement of the feeder piller box/ LT panel as per site requirement or directed including applying one coat of cement base point after preparation of surfaces and testing complete as per direction of Engineer- in- charge. Note:- Cost of Painting, Nuts, bolts, washer etc. are deemed to be included in quoted rates.

4

-

-

... More
Supply and Fix RCCB 4 pole 25A 30mA sensitivity degree of protection IP20 conforming to IS 12640 (Part 1) / IEC 61008-1 including taking down old unserviceable one complete all as specified and as directed.

4

-

-

... More
Supply and fix relay 3/5 A resistive at 24V DC/ 240V AC plug in type 2 pole complete all as specified and directed

6

-

-

... More
Taking out unserviceable steel poles of any type and any sizes from the site of work complete all as specified and directed.

3

-

-

... More
M & L steel tubular sewaged pole 9 mtr long completed with MS base plate, finial taper plug nut bolts, screws as specified type 410 SP-31 as per relevant IS specifiecation including two coats of aluminimum paint over a coat of red oxide primer complete all as specified and as directed by Engineer-in-Charge. Note : Earth work/excavation PCC shall be measured and paid seperately.

3

-

-

... More
M & L for Scraping, cleaning and preparation of surface of all steel tubular sewaged pole 9 mtr long, cross arms, clamps GI street light bracket etc and applying two coat of aluminium paint including writing pole number & bottom of pole painted with black paint with yellow strip allround between the juction of aluminium paint and black paint complete as directed and specified.

10

-

-

... More
M&L Danger notice plate of 1.6mm thick for LT 20x15 cm mild steel sheet vitreous enamelled white with etters ,figures,and conventional skull and bones in signal redcolour and fixed with Ms clamp bolts and nuts complete all as specified and as directed.

10

-

-

... More
Materials and Labour Cutting /boreing of existing road / path , hardstandingetc for taking out cable and water pipe to protection with iron cover plate for passing cable,water pipe and making good the disturbed road top surfaces with following cement concrete all type, using of suitable depth and finished with speed breaker complete all as uder directed by Engineer-in-Charge.

30

-

-

... More
Supply and Laying Steel Water Tubing 80mm Bore (dia), Galvanised, ‘Medium Grade’ with all Fittings, laid in trenches or any other Situation, complete as all specified and as directed.

10

-

-

... More
Supply and Laying Steel Water Tubing 50mm Bore (dia), Galvanised, ‘Medium Grade’ with all Fittings, laid in trenches or any other Situation, complete as all specified and as directed.

10

-

-

... More
Supply and Laying Steel Water Tubing 40mm Bore (dia), Galvanised, ‘Medium Grade’ with all Fittings, laid in trenches or any other Situation, complete as all specified and as directed.

10

-

-

... More
Supply & fixing Changeover Switch in sheet steel enclosure, four pole, 315 Amps, Manual type, 415 V including taking down old unserviceable one complete all as specified and as directed.

1

-

-

... More
Supply & fixing Changeover Switch in sheet steel enclosure, four pole, 400 Amps, Manual type, 415 V including taking down old unserviceable one complete all as specified and as directed.

1

-

-

... More
S&F hot dipped galvanised (Z+) wiremesh cable tray outdoor type with wire dia from 3.9 mm to 5.9 mm of size 3000mm x 54mm x 100mm including supports, manufactured with a longitudinal 'T' welded safety edge, Trays shall be constructed with 50mm /100 mm mesh configuration, Accessories for coupling and making 'T's and bends CE25/CE30 screw based system combination must be used and mounting accessoriesare required of same finish of same manufacturer as per the site requirement (ceiling/wall mounted), trays should comply Standard EN ISO14 61: at least 550 hours of SST, The deflection of cable tray must be within 1/200th of the distance between two supports and tested in accordance with the Standard IEC 61537, Wire cable trays must be designed with an optimum span of 1.5 metres taking into account the maximum load carrying capacity as authorised by the manufacturer, Assembly with fire resistant properties must have E30/E90 certificates including S&F of KI Taster for joining of two cable trays with fixing arrangement and Wall Bracket for 100MM Tray and cable tray cutting with Coupfil - Cablofil Bolt Cutter complete all as specified and as directed. Note:- The load capacities of the brackets and the hanger torques must be tested in accordance with the Standard IEC 61537 and no hot work of trays shall be allowed on site

50

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.