Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.
Military Engineer Services - MES Tender
Civil And Construction
Solid Waste Management
Drainage Work
Eprocure
Opening Date8 Mar 2025
Closing Date20 Mar 2025
Tender Amount₹ 29,98,200
Costs
EMD
₹ 60,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_700685_1Tender No
8500-291/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Materials and labour for brick work with old size flyash bricks, straight or curved on plan exceeding 6 meter mean radius for manholes /septic tank /soak well etc in sewer works in CM 1:4 complete all as specified and directed by Engr-in-Charge.
16
-
-
... More
All as per BOQ Srl Item No 4.00 here-in-before but except bricks
15
-
-
... More
Excavating in trenches , n.exc 1.5 m wide and n.exc 1.5 m depth for foundation etc or for shafts, wells, cesspits ,manhole pier hole, laying of cables, pipes etc n.exc 10 sqm on plan and n.exc 1.5m in depth and getting out in any kind of soil
Note : Manual excavation to be done. During excavation if any damage occured to existing cable any type/ water pipe line, it will be contractor responsibilty to get it repair and make functional by providing jointing kit etc without any extra cost. Contractor has to repair it within 24 hrs so that essential service can not be effected due to such damage.If contractor fails to repair it within 24 hrs penalty @ Rs 500/- will be charged to contractor. In this GE decision will be final, conclusive and binding.
15.9
-
-
... More
All as per BOQ Srl Item No 6.00 here-in-before but depth exc 1.50 m and not exc 3.00 meter
2.63
-
-
... More
Excavation over area ,not exc 1.5 mtr deep and getting out in loose/soft soil complete all as specified and directed by Engr-in-Charge.
23.92
-
-
... More
All as per BOQ Srl Item No 8.00 here-in-before but depth exc 1.50 m and not exc 3.00 meter
22.5
-
-
... More
Returning, filling in incl spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft /loose soil complete all as specified and directed by Engr-in-Charge.
12.99
-
-
... More
Removing excavated material in soils n exc. 50 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed by Engr-in-Charge.
51.96
-
-
... More
M&L for PCC 1:3:6 type C-2 (40 mm graded stone aggregate) in foundation filling and mass concrete for bottom of manhole and sub base of floor complete all as specified and directed by Engr-in-Charge.
9
-
-
... More
Demolition and breaking up drain pipe (SGSW/PVC/RCC etc) set in cement mortar of internal dia of pipe 150 mm complete all as specified and directed by Engr-in-Charge.
120
-
-
... More
All as per BOQ Srl Item No 13.00 here-in-before but internal dia of pipe 200 mm.
50
-
-
... More
Supplying and laying of PVC underground dranage sewer system pipe bearing 160 mm dia of pressure rating 8KN/Sqm laid in tranches and joined with cement solvent including jointing with couplar ,bend tee as per site requirement complete all as specified and directed by Engr-in-Charge.
120
-
-
... More
All as per BOQ Srl Item No 15.00 here-in-before but dia of pipe 200 mm..
50
-
-
... More
M&L for concrete bed to 200 mm dia drain pipes including forming cradles after they are laid and tested in cement concrete 1:3:6 type C-2 complete all as specified and directed by Engr-in-Charge.
40
-
-
... More
M&L for concrete bed to 150 mm dia drain pipes including forming cradles after they are laid and tested in cement concrete 1:3:6 type C-2 complete all as specified and directed by Engr-in-Charge.
120
-
-
... More
M&L for concrete bed to 300 mm dia drain pipes including forming cradles after they are laid and tested in cement concrete 1:3:6 type C-2 complete all as specified and directed by Engr-in-Charge.
40
-
-
... More
Taking down cement plaster from inside/outside of existing septic tank/manholes drain and outer surface of bldgsetc incl raking out joints, hacking for key scrubbing down with water and removal rubbish off the premises complete all as specified and directed by Engr-in-Charge.
300
-
-
... More
M&L 15 mm thick rendering in cement mortar 1:3 inside including WPC to wall of manhole,drain,bldgs, of brick work/concrete suface even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge.
100
-
-
... More
M&L 15 mm thick rendering to outside of wall in cement mortar 1:4 including finish the surface even & fair complete all as specified and directed by Engr-in-Charge.
200
-
-
... More
Supply only liquid water proofing compound
4.51
-
-
... More
M&L type B-1 1:2:4 (20mm graded stone aggregate) providing RCC precast cement concrete as in cover slab for manhole and similar article with plain face set in cement mortar 1:6 complete all as specified and directed by Engr-in-Charge.
8
-
-
... More
M&L for reinforcement cement concrete(nominal mix) type A1 1:1.5:3 (20mm graded aggregate) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like for septic tank /soakage well pits slab complete all as specified and directed by Engr-in-Charge.
3.6
-
-
... More
M&L for Steel Centering and shuttering including strutting, propping etc. and removal of form to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, not exceeding200mm thick with for fair and finished surfaces complete all as specified and directed by Engr-in-Charge.
40
-
-
... More
Material and labour for 6mm to 8mm dia mild steel TMT bar, cut to length, bent to shape required, incl cranking bending and binding with MS wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engr-in-Charge.
624
-
-
... More
M&L TMT bars 10mm dia, and over cut to length bent to shape required including cranking, bending spirally for hoping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engr-in-Charge.
280.8
-
-
... More
Taking down eaves gutters and rainwater/SWR/RCC pipes (any size or pattern), including all fittings, heads, shoes, bends, swan necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories), complete all as specified and directed by Engr-in-Charge.
105
-
-
... More
S & F for PVC (SWR) pipes of 110 mm dia single socketed in any length with rubber ring joints fixed to walls, including with clamps etc complete all as specified and directed by Engr-in-Charge.
50
-
-
... More
S & F for PVC (SWR) pipes of 75 mm dia single socketed in any length with rubber ring joints fixed to walls, including with clamps etc complete all as specified and directed by Engr-in-Charge.
25
-
-
... More
S & F for PVC (SWR) pipes of 75 mm dia single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed by Engr-in-Charge.
30
-
-
... More
S & F in repair PVC (SWR) bends any radius of 110 mm bore with access door complete all as specified and directed by Engr-in-Charge.
20
-
-
... More
S & F in repair PVC (SWR) bends any radius of 75 mm bore with access door complete all as specified and directed by Engr-in-Charge.
20
-
-
... More
S & F PVC (SWR) reducers of 110 mm bore complete all as specified and directed by Engr-in-Charge.
10
-
-
... More
S & F PVC (SWR) reducers of 75mm bore complete all as specified and directed by Engr-in-Charge.
10
-
-
... More
S&F 110mm PVC (SWR) vent cowl complete all as specified and directed by Engr-in-Charge.
5
-
-
... More
S&F 75mm PVC (SWR) vent cowl complete all as specified and directed by Engr-in-Charge.
10
-
-
... More
S&F 110mm PVC (SWR) junction single (simgle T) equal or unequal complete all as specified .
10
-
-
... More
S&F 75mm PVC (SWR) junction single (simgle T) equal or unequal complete all as specified and directed by Engr-in-Charge.
10
-
-
... More
S&F in repair 100mm dia spun cast iron soil ,waste and vent pipe , in any length with or without ears, with cement joints, fixed to walls complete all as specified and directed by Engr-in-Charge.
10
-
-
... More
S&F in repair 75mm dia spun cast iron soil ,waste and vent pipe , in any length with or without ears, with cement joints, fixed to walls complete all as specified and directed by Engr-in-Charge.
10
-
-
... More
S&F in repair 100mm dia CI bends (any radius) with oval access doors complete all as specified and directed by Engr-in-Charge.
20
-
-
... More
S&F in repair 75mm dia bends (any radius) with oval access doors complete all as specified and directed by Engr-in-Charge.
10
-
-
... More
Dismantling of cast iron drain pipes and re-fixing 100mm dia spun cast iron soil ,waste and vent pipe , in any length with or without ears, with cement joints, fixed to walls complete all as specified and directed by Engr-in-Charge.
25
-
-
... More
Dismantling of cast iron drain pipes and re-fixing 75mm dia spun cast iron soil ,waste and vent pipe , in any length with or without ears, with cement joints, fixed to walls complete all as specified and directed by Engr-in-Charge.
10
-
-
... More
M&L for Cover /lid for oval access door suitable for 100 mm bore CI bends fixed with bolts and rubber washer including painting with two coats of bituminous paint complete all as specified and directed by Engr-in-Charge.
50
-
-
... More
M&L for Cover /lid for oval access door suitable for 75 mm bore CI bends fixed with bolts and rubber washer including painting with two coats of bituminous paint complete all as specified and directed by Engr-in-Charge.
25
-
-
... More
Dismantling floor/hearth or wall tiling including cement mortar bedding (but not backing), removing rubbish off the premises complete all as specified and directed by Engr-in-Charge.
229
-
-
... More
M&L for coloured non skid ceramic tiles 7 to 8 mm thick (Square /rectangular) area of each tile exceeding 0.06sqm but not exceeding 0.11 sqm, in floors etc set and jointed in neat cement slurry and including 20 mm thick screed bed in cement mortar 1:6 complete all as specified and directed by Engr-in-Charge.
50
-
-
... More
M & L Glazed ceramic colour tiles in vertical surface 450x 300x 7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match and including rendering 10 mm thick cement plaster in CM 1:3 on brick work or concrete surfaces of wall complete all as specified and directed by Engr-in-Charge.
100
-
-
... More
S&F in repairs closet Vitreous china squatting pan Orissa pattern of size 580x440mm white with integral foot rests (excluding flusing cistern and flush pipe) including connection to trap and to flushing pipe, antisyphonage connection pipe etc complete making good disturb surface with existing finish of floor complete all as specified and directed by Engr-in-Charge.
12
-
-
... More
S&F in repairs vitreous china wash down water closet pan, pedestal pattern Pedestal pan and trap(excluding flushing cistern and flush pipe),connection to drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe, etc and including plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel CP or aluminised hinging device complete all as specified and directed by Engr-in-Charge.
10
-
-
... More
S&F in repair Vitreous China bowl urinal flat back, size of 465 x 355 x 265 mm white minimum), with grating and union for discharge pipe(back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe complete all as specified and directed by Engr-in-Charge.
8
-
-
... More
Supply and fixing in repair 10mm thick curved shape glass partition of selected quality frosted / pin headed glass as in partition or urinal partition of required size including stainless steel holding brackets and stainless steel screws to secure complete all as directed by Engineer-in-charge
4
-
-
... More
S&F in repair 32 mm bore Waste coupling of PTMT (half or full threaded) (Minimum weight 32mm45gms) for urinal complete all as specified and directed by Engr-in-Charge.
10
-
-
... More
S&F in repair for PVC waste pipe 32mm dia for wash basin/urinal (length- 1 RM) complete all as specified and directed by Engr-in-Charge.
40
-
-
... More
Supply and fixed in repairs floor mounted (single piece WC) bowl with cistern for coupled WC with and including UF soft close slim seat cover, hinges, dual flush cistern fitting, fixing accessories and accessories set complete of size 380x655x765 mm with S Trap- 250 mm, connector to branch soil pipe and anti syphonage pipes etc. including sealing the joints and making leak proof using sealant complete all as specified and as directed by Engineer-in-Charge.
2
-
-
... More
Supply and fixed in repairs vitreous china one piece wall mounted toilet seat with UF seat cover, hinges, fixing accessories set , cistern fittings pattern white of size Size=380x650x730mm including trap
1
-
-
... More
S& F in repair water closet seat cover white coloured pattern with flat bottom and cover and mild steel chromium plated or aluminium hinging devised for any size any type complete all as specified and directed by Engr-in-Charge.
10
-
-
... More
S&F in repair 10 litre capacity PVC low level flushing cistern with all accessories complete fixed with WC including syphone pipe, PVC flushing pipe of size complete (w/o brackets) complete all as specified and directed by Engr-in-Charge.
10
-
-
... More
S & F in repair flush pipe of polyethylene of low or high density of PVC, 32 mm dia, for low level cistern complete all as specified and directed by Engr-in-Charge.
10
-
-
... More
S & F in repair grating square/Circle 150mm size of PTMT (minimum 100 gms) complete all as specified and directed by Engr-in-Charge.
25
-
-
... More
S & F in repair grating square/Circle 125 mm size with waste hole of PTMT (minimum 40 gms) complete all as specified and directed by Engr-in-Charge.
20
-
-
... More
M & L for forming fair finish drain channel 30 cm inner grith in cement concrete using extra cement complete all as specified and directed by Engr-in-Charge.
50
-
-
... More
M & L for cement concrete type B-0 1:2:4 (12.5mm graded stone aggregate) in cills, steps, plinth courses, string courses, lacing courses, parapets, copings, kneelers, apex stones, bed plates, kerbs water troughs and the like including weathering, slightly rounded for chamfered angles and throating, as directed rounded or chamfered on edges complete all as specified and directed by Engr-in-Charge.
3
-
-
... More
M&L for 75 mm thick cement concrete M10 (Nominal Mix) with 40mm graded crushed aggregate finished even and fair laid to a slope of 1 in 12, laid in alternate bays, each bay not exceeding 3 m length with joint filled with bituminous mastic filling comprising a mixture of 1 part of heated Industrial bitumen 85/25 grade and two parts of heated sand complete all as specified
120
-
-
... More
Material and labour for 25 mm thick chequered cement concrete tiles of size 300x300mm set ,jointed and pointed using with grey cement and pigment in floors, pavings etc including the setting and jointing in neat cement plaster or slurry 3 kg/sqm over 20mm thick screed bed or bedding layer in cement mortar 1:6 complete all as specified and directed by Engr-in-Charge.
79
-
-
... More
Taking up or down steel tubing and connection including cleaning for refixing or removed to store, 15 mm dia bore complete all as specified and directed by Engr-in-Charge.
25
-
-
... More
Fixing only in steel tubing and connection 15 mm dia bore complete all as specified and directed by Engr-in-Charge.
10
-
-
... More
S&F GI tubing 15mm bore medium grade with all fittings and fixed complete to wall and ceiling or laid in floors complete all as specified and directed by Engr-in-Charge.
15
-
-
... More
Uprooting of plants of any girth from RCC/Brick surfaces, pouring of acid chemical over root and making good in CM 1:3 or PCC 1:2:4 type B0 using 12.5mm graded aggregateincludingall accessories to reach the area of plant growth in buildings etc complete all as specified and directed by Engr-in-Charge.
100
-
-
... More
Cutting into existing manholes 150mm dia pipe for connecting new drains making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B1 smooth finished and reforming benching as required complete all as specified and directed by Engr-in-Charge.
10
-
-
... More
Cutting into existing manholes 200mm dia pipe for connecting new drains making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B1 smooth finished and reforming benching as required complete all as specified and directed by Engr-in-Charge.
15
-
-
... More
Cutting into existing manholes 300mm dia pipe for connecting new drains making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B1 smooth finished and reforming benching as required complete all as specified and directed by Engr-in-Charge.
5
-
-
... More
Surface dressing in any type of soil not exc 15 cm deep in foul condition for removing heaps of wastes, cleaning of flora, fauna, foliage and bushes around septic tanks, soakage well, manholes and along sewage line and removing debris/heaps of bushes etc from vicinity and depositing at a place where complete all as specified and directed by Engr-in-Charge.
500
-
-
... More
Cleaning and desilting of sewage lines upto 150mm dia and depth up to 1.50m, cleaning the lines by manual roding/mechanically jet pumps/sewage cleaning mechenie as required at site as per rule 5 and protective gear and safety devices as per rule 4 of the Prohibition of Employment as Manual Scavengers and their Rehabilitation Rules, 2013 and removing blockage and flushing out by means of pumping out/removing liquid waste/sewage, plugging the ends pipes or diverting the flow into drains if necessary, removing silt sludge etc, sprilinkling bleaching powder on the silt to avoid smell including all precautionery and saftey measures, such as saftey belts, ligthting arrangement face mask gloves etc and removing the same ( silt, sludge & other waste material) in leak proof trucks covered with tarpoline to out side of MD land as per existing rules and regulation of civil authorities and flushing the sewage lines with fresh water complete all as specified and as directed. Unit rate quoted shall deemed to be included of cleaning of shrubs, grass small roots etc. around the Manholes, Inspection chamber etc and along sewage lines wherever required or as directed and no extra payment shall be made on this account) etc complete all as specified and directed by Engineer-in-charge
5000
-
-
... More
All as per item No, 77.00 here-in- before but dia exceeding 150mm to 300mm complete all as specified and directed
1500
-
-
... More
Cleaning of blockage of existing sewage system and plumbing system (Comprising of sewer line in CI, SGSW or SG pipes) , house connection from WC, bath, Kitchen etc including gully traps, floor/Nahani traps, CI Pipes and plumbing work etc of any description and in any position below or above ground level, located in different situations to remove of all solid or liquid wastage to make the entire system functional as directed by Eng-in-Charge
2160
-
-
... More
Cleaning of manholes of any description , depth not exceeding 1.50 metre, using the cleaning devices as per rule 5 and protective gear and safety devices as per rule 4 of the Prohibition of Employment as Manual Scavengers and their Rehabilitation Rules, 2013 and removing the sludge and solid contents in covered container outside MD land complete all as specified and as directed. Unit rate quoted shall deemed to be included of cleaning of shrubs, grass small roots etc. around the Manholes, Inspection chamber etc and along sewage lines wherever required or as directed and no extra payment shall be made on this account and .measurement shall be taken after allowing initial percolation of sludge water and only dried sludge shall be measured ).Note (i) disposal is responsiblity of contractor after lisening with the local authority/munispulity. (ii) Quoted rates are deemed to be included the all factors.
300
-
-
... More
All as per item No 80.00 here-in- before but depth of manhole exceeding 1.50 metre but not exceeding 3 metres complete all as specified and directed by Engr-in-Charge.
100
-
-
... More
Material, T&P and labour for cleaning/ desludging of septic tank of any capacity using the cleaning devices as per rule 5 and protective gear and safety devices as per rule 4 of the Prohibition of Employment as Manual Scavengers and their Rehabilitation Rules, 2013 and removing the sludge and solid contents in covered container outside MD land complete all as specified and as directed. Unit rate quoted shall deemed to be included of cleaning of shrubs, grass small roots etc. around the Manholes, Inspection chamber etc and along sewage lines wherever required or as directed and no extra payment shall be made on this account and .measurement shall be taken after allowing initial percolation of sludge water and only dried sludge shall be measured ).Note (i) disposal is responsiblity of contractor after lisening with the local authority/munispulity. (ii) Quoted rates are deemed to be included the all factors.
60
-
-
... More
M&L for Dewatering/pumping of soak well/filter bed at different locations completely of size not exc 1.80 mtr dia and not exc 4.50 mtr depth mechanically only with using sewage tankers /truck mounted hydraulic jet pressure machine with heavy duty flushing the sewage line and with heavy duty sewage pumps sewage suction pump including necessary other arrangements such as sweepers to clean up the site after work including taking out /removing all material such as sludge/soil waste /polythene /mud/silt /liquid/semi liquid /night soil waste etc by only sewage suction pipe including flushing with adequate water to make the same sewage system fully functional to the entire satisfaction of engr-in charge, re-fixing the existing opened access cover and removing all retrieved material/unwanted /foreign material in any liquid /solid state etc outside the periphery of defence land at his own arrangement where sanitary hazards do not take place as per directions/instructions of civil authority and buried in excavated pits in suitable size and depth and covering the same minimum 25cm thick compacted layer of soil with soil obtained from excavation of pit including all excavations and earth work including applying bleaching powder to maintain hygiene adequate water for flush out be arranged by the contractor without any extra cost complete all as specified and directed . Note :- A particular soak well/filter bed which is undertaken once for cleaning and paid for shall be kept functional for entire contract period and no extra payment shall be made for repetitive cleaning if required.
50
-
-
... More
All as per Ser item No 83.00 here in before but of dia beyomd 1.80 mtr upto 3.00 metre dia and depth beyond 4.50 meter upto 6 metres depth .
5
-
-
... More
M&L Cast iron Bends upto 150 mm bore (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch. "Y" junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs complete all as specified and directed by Engr-in-Charge.
20
-
-
... More
M&L Reinforced concrete pipes, class NP2, 150 mm dia laid and jointed complete with collars complete all as specified and directed by Engr-in-Charge.
50
-
-
... More
M&L RCC Bends, bore 150 mm laid and jointed, complete all as specified and directed by Engr-in-Charge.
10
-
-
... More
M&L Single 'Y' junctions 150 mm bore laid and jointed, complete all as specified and directed by Engr-in-Charge.
10
-
-
... More
M&L Reinforced concrete pipes, class NP2, 200 mm dia laid and jointed complete with collars complete all as specified and directed by Engr-in-Charge.
20
-
-
... More
M&L RCC Bends, bore 200 mm laid and jointed, complete all as specified and directed by Engr-in-Charge.
8
-
-
... More
M&L Single 'Y' junctions 200 mm bore laid and jointed, complete all as specified and directed by Engr-in-Charge.
8
-
-
... More
M&L Reinforced concrete pipes, class NP2, 300 mm dia laid and jointed complete with collars complete all as specified and directed by Engr-in-Charge.
15
-
-
... More
M&L RCC Bends, bore 300 mm laid and jointed, complete all as specified and directed by Engr-in-Charge.
5
-
-
... More
M&L Single 'Y' junctions 300 mm bore laid and jointed, complete all as specified and directed by Engr-in-Charge.
5
-
-
... More
M&L Cast iron pipes 150 mm dia with flanged ends, centrifugally cast, class A, in any length laid in trenches complete all as specified and directed by Engr-in-Charge.
10
-
-
... More
S&F in repair Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified and directed by Engr-in-Charge.
10
-
-
... More
S&F in repair Toilet paper holder with flat recessed type stainless steel Toilet paper holder of vitreous china fixed to walls with brass, chromium platedn or stainless steel complete in all respect as specified and directed by Engr-in-Charge.
10
-
-
... More
M & L for forming fair finish drain channel 45 cm inner grith in cement concrete using extra cement complete all as specified and directed by Engr-in-Charge.
50
-
-
... More
S&F in repair Waste coupling for wash basin of PTMT (half or full threaded) . (Minimum weight 32mm-45gms) complete all as specified and directed by Engr-in-Charge.
5
-
-
... More
S&F in repair Vitreous China urinals,(Half Stall), bowl type (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) complete all as specified and directed by Engr-in-Charge.
10
-
-
... More
Taking up or down steel tubing and connection including cleaning for refixing or removed to store, 20 mm dia bore complete all as specified and directed by Engr-in-Charge.
100
-
-
... More
Fixing only in steel tubing and connection 20 mm dia bore complete all as specified and directed by Engr-in-Charge.
10
-
-
... More
S&F GI tubing 20mm bore medium grade with all fittings and fixed complete to wall and ceiling or laid in floors complete all as specified and directed by Engr-in-Charge.
90
-
-
... More
Note: For Sl item No, 77 to 84 above contractor shall adhere Note : 1 Minimum four sweeper per day with T&P mechanical equipment shall be provided by the contractor on each working day for 8 hours per day for any type of blokage of sewer lines with T&P / mechanical equipment (if required jet spray cleaning machine mounted on truck with adequate pipe arrangement to reach the manhole away from the road as directed by Engineer-in-charge) shall be provided by the contractor on each working day other than Gaztted holiday, for 8 hours per day for any type of blockage incl sewer lines of any dia Note : 2. The contractor/superviser representative alongwith min two sweepers will report at 0900 hrs to the sub division for complaints and submit completion report at 1700 hrs everyday. Note 3: The complaint of sewer lines shall be attend and complete with in 24/48 hrs, if the contractor fails to do so a recovery opf Rs. 500/- per day per complaint will be deducted for the delay period for Sl item no. 77 to 84 above depend on the urgency as decided by Engineer-in-Charge.
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%