Military Engineer Services Tender
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.
Military Engineer Services - MES Tender
Civil And Construction
Excavation
Eprocure
Opening Date30 Nov 2024
Closing Soon28 Dec 2024
Tender Amount₹ 36,50,000
Costs
EMD
₹ 73,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_686551_1Tender No
8701/68/2024-2025/05/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Demolition of cement concrete (reinforced) in ground floors and paving n exc 15 cm thickness (below or above ground level) complete all as specified and directed.
3.5
-
-
... More
Suplly and filling Silver Sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed.
205
-
-
... More
Supply and filling Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including waterin complete all as specified and as directed.
40
-
-
... More
M&L RCC M- 30 design mix using 20 mm graded stone aggregate in foundation , including rafts, footing , foundation beams, plinth beam , bases for column, slab for culvert etc complete as specified and directed by Engr-in-Charge
59.5
-
-
... More
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams in flate and similar work; vertical or to batter rough finished surfaces of concrete
120
-
-
... More
M&L RCC M- 30 design mix using 20 mm graded stone aggregate in Columns, pillars, piers, posts and struts etc complete as specified and directed by Engr-in-Charge
11.2
-
-
... More
Use and waste of form work to faces of sides of pillars, posts, struts, piers, columns and stanchions in flats vertical rough finished surfaces complete all as specified and directed.
21
-
-
... More
M&L RCC M- 30 design mix using 20 mm graded stone aggregate in Beams, cantilevers, bressummers, lintels over 1.5m span etc complete as specified and directed by Engr-in-Charge.
9.6
-
-
... More
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams fair finished surfaces , etc complete all as specified and directed
55
-
-
... More
M&L TMT bars 10mm dia and over in reinforcement cut to length bent to shape required incl hooking ends and binding with MS wire (annealed) not less than 0.9 mm dia all as specified.
6250
-
-
... More
Material and labour for TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders. cut to length, bent to shape required including cranking and bending and binding with MS wire (annealed) not less than 0.9 mm dia complete all as specified and as directed.
2080
-
-
... More
M&L brick work for fly ash built in CM (1:6) with straight or curved on plan exceeding 6 mtr mean radius all as specified.
49.8
-
-
... More
M & L 15 mm cement plaster on brick work or concrete surface in CM (1:4) surface finished even and smooth without using extra cement complete all as specified and as directed.
392
-
-
... More
Supply only integral water proofing compound complete all as specified and directed
109.13
-
-
... More
M&L Applying two coats of Asure Radiance exterior Emulsion paint (7 year warranty) over one coat of Azura Premium Damp Arrestor alkali block dual primer complete all as specified.
392
-
-
... More
M&L for RCC (1:2:4) type B-1 Using 12.5mm graded stone aggregate as in copings including Ditto, in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directednecessary form work complete all as specified and directed.
4
-
-
... More
Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide all as specified and direceted
110
-
-
... More
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm.
27
-
-
... More
M&L PCC 1:2:4 type B-2 (using 40mm graded stone aggregates) foundation fillings and mass concrete complete all as specified and directed.
10.38
-
-
... More
Supply & Fixing for 2.24mm dia 2 strand galvanised steel barbed wire with 2mm dia barbs at 75mm spacing and staining and fixing to any type of standard railing strainning both including securing or tying at crossing with and provision of galvanised mild steel wire, staples or steel pin etc after and including dismantling of existing unserviceable barbed wire complete all as specified and as directed by the Engr-in-Charge.
3.3
-
-
... More
Supply & Fixing stainless steel concerntina coil fencing with punched tape concerntina coil 600mm dia 10 mtr openable length (total length 90mtr), having 50 nos round per 6 mtr length upto 3 mtr heigth of wall with 9 horrizsontal RBT reinforced barbed wire, stud tied with GI satples and GI clips to retain horrizontal, including nessesary bolts or GI barbed wire tied with angle iron complete all as specified and as directed
55
-
-
... More
M & L for hardcore of broken bricks of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and as directed.
85
-
-
... More
S&F for mild steel work as in posts and struts etc in fencing including cutting tops to shapes as directed, drilling holes, notching for wire etc flat iron fillets (for securing wire mesh etc) including all necessary drilling, bolting or riveting, etc and similar work conforming to Fe-290 Gde E-165 complete all as specified
147.5
-
-
... More
Bringing locally availabilty earth from sources outside defence land including cost of royality if any, transportation, taxes, etc and filling with soil incl raising earth, spreading in layers n exc 30cm thick, watering, ramming with 8 to 10 tonne power roller and finished with required size and shape.
648
-
-
... More
Supply and fixing of die cast aluminium housing transparent tempered glass diffuser matt grey finish LED warm white wall washer light 12 watt,IP-54 including fixing to wall complete all as specified and as directed.
20
-
-
... More
M & L Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLSH PVC insulated copper conductor, single core cable in surface/ recessed as required in PVC Conduit conceiled type 2x2.5sq. mm + 1x2.50 sq. mm for earth wire all as specified and directed.
50
-
-
... More
S & F LED bollard lights nominal power 12 Watt, operational voltage of 120 volts to 300 volts, frequency of 50 Hz, lumen efficacy of minimum 100 lumens per watt, and LED lumnous Efficacy 130 Lumen per watt built-in integrated electronic LED driver with minimum 85% efficiency, output open / short circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 4 KVs, protection grade IP 65, CRI greater than 80%, CW available CCT of 5700K, power factor of minimum 0.95, high grade pressure die-cast aluminium alloy of 800 mm height and 165 mm dia housing with optics used PMMA, life span of minimum 50000 working hours including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable for outdoor use, 1.5 sqmm as per IS 694: 2010 complete all as specified and as directed.
12
-
-
... More
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10.0 sq mm 4 core (for garden light)
50
-
-
... More
Excavation in trenches, n. exc. 1.5m wide and n. exc. 1.5m in depth; for laying of cable, n. exc 10 sqm on plan and n exc 1.5 m in depth and getting out in soft/loose soil.
13.5
-
-
... More
Removing excavated material n. exc. 50 m and depositing where directed at a level n. exc. 1.5 m above the starting point
9.83
-
-
... More
M&L Dry sand filling as cable cushoining complete. Note - Thickness for sand shall be measured after punning down 23 cm layer complete all as specified and as directed.
5.18
-
-
... More
Supplying and laying un-reinforced precast concrete cable cover, class LV, type 1 with peak, size 250mm x 150mm x 40mm along length of cable in trenches after sand cushioning laid for underground cable protection complete all as specified and as directed
333.33
-
-
... More
Supply and fixing SP 6-32 amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning.
4
-
-
... More
Supply and fixing SPN 20/32 amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning.
1
-
-
... More
Supply and fix 8 way SPN Double door DB with 100 amps rated bus bar complete all as specified and as directed
1
-
-
... More
Supply and fixing suitable programmable electronic 110 240 VAC crono timer switch, 50 Hz suitable for controlling landscape lights Precise time programming for - daily / weekly, pulse switching complete all as specified and as directed
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%