Military Engineer Services Tender

Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.

Military Engineer Services - MES Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date17 Jan 2025
Closing Date7 Feb 2025
Tender Amount₹ 41,70,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Dismantling wrought iron or mild steel work of any description.

2

-

-

... More
S&F Roof trusses (framed), trussed,purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc confirming to Fe 410-W (Gde 250 quality A) complete all as specified and directed.

150

-

-

... More
S&F of joist, channel, angle, flat iron or Tee sections, fixed independently with connecting plates, etc confirming to Fe 410-W (Gde 250 quality A) complete all as specified and directed.

50

-

-

... More
Dismantling wall and ceiling boards (fiber, pulp, insulation etc) or insulation boards/slabs/blankets, any thickness including cover fillet complete all as specified and directed.

80

-

-

... More
S&F false ceiling with powder coated exposed GI grid suspension system (E-Grid T-2430 or equivalent load carrying capacity with mid span deflection not exc. 1/360 span with hanger spacing of 1200mm c/c) consisting of main runner 3600mm long, cross Tee 1200mm/600mm long and wall angle. The main runners to be placed @ 1200mm, the cross Tee 1200mm will be inserted in the pre cut slots of main runner at a regular interval of 600mm to form a modular grid of 1200mmX600mm. Additional cross Tees of 600mm shall be placed perpendicular to the cross tee 1200mm long to finally form a grid of 600mmX600mm. Suspensor system (Grid) made out of GI sheet main Tee of size 23.5mmx38.50mmX0.36mm and cross Tee of size 23.5mmX23.5mmX0.36mm and angle size 19mmx19mmX0.36 mm. Grid of modular size 600mmX600mm shall be supported by 4 mm dia G.I. wire from purlins/soffit with and including 4mm thick high pressure steam cured non asbestos fiber cement designer ceiling board (Density1200Kg/Cum) of size 595mmX595mm, confirming IS 14862 & Type B Category III of ISO 8336, tested as per AS 1530 part 3 & BS-476 Part 4, 5, 6, 7 & 8, complete all as per manufacturer's instruction. (Make : Everest or equvalent as approved by GE)

80

-

-

... More
Roughening surfaces of lod concrete floor by picking, sweeping clean and washing down with water to remove dust etc including brushing near cement slurry @3 Kg per sqm complete all as specified and directed.

143

-

-

... More
Dismantling floor, hearth or wall tiling including cement mortar bedding but not backing, removing rubbish off the complete all as specified and directed.

261

-

-

... More
M&L for non skid ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the surfaces of tile over and including 20 mm thick screed bed in cement mortar (1:6) complete all as specified and directed.

116

-

-

... More
M&L for coloured & polished Chequered cement concrete tiles 30cm x 30cm x 25mm thick,set, jointed and pointed in neat cement slurry as in floors includig 20mm thick screed bed CM(1:6) all as specified and directed.

25

-

-

... More
M&L for non skid ceramic coloured tiles 7 to 8 mm thick premium quality conforming to relevant IS (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the surfaces of tile over and including 15 mm thick screed bed in cement mortar (1:6) complete all as specified and directed.

116

-

-

... More
M&L 350x 250x 7 mm or 450X 350X 7mm thick coloured glazed ceramic tiles fixed as in vertical surface such as risers of steps, skirting, dado etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile over and including 15 mm thick rendering in CM (1:4) finished even and rough complete all as specified and directed.

120

-

-

... More
Demolition of cement concrete (unreinforced) in ground floor and pavings not exc 15 cm thickness (below or above ground level) complete all as specified and directed.

1.5

-

-

... More
M&L for 50 mm thick cement concrete (1:3:6) type C-2 (using 40 mm graded crushed stone aggregate) as in plinth protection/path laid to slope of 1 in 12 and finishing cement concrete surface even and smooth without using extra cement with and including all necessary form work to divide the area in panels, finishing exposed edges fair or rounding or chamfering of exposed edges complete all as specified and directed.

30

-

-

... More
Taking down cement plaster on brick or stone masonry surfaces of walls etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.

190

-

-

... More
M&L Rendering 5mm thick on fair faces of brick work or concrete surfaces cement mortar (1:3) on concrete surface as in ceiling/chajja and RCC surfaces , to be finished even and smooth (without using extra lime or cement)complete all as specified.

30

-

-

... More
M&L 15 mm thick rendering ( in two coats 10mm+5mm) on fair faces of brick work or concrete surface in cement mortar (1:4) on external wall finished even and fair mixed with integral water proofing compound @ 3% by weight of cement in 2nd coat or in the manner specified by the manufacturer and in the proportions indicated all as specified and as directed. Note:-WPC will be measured and paid separately as supply only.

40

-

-

... More
Supply only integral water proofing compond all as specified and as directed.

4

-

-

... More
M&L for 10 mm thick rendering in cement mortar (1:6) on Brick/stone masonry surfaces or surfaces other than fair faces of brick work, rendering finished even and fair (without using extra cement) complete complete all as specified and directed.

120

-

-

... More
M&L for preparation of newly plastered surfaces and applying three coat of cement base paint complete all as specfied and directed.

40

-

-

... More
M&L preparation of newly plastered surfaces of wall and applying two coats of oil bound distemper over 3mm thick wall care putty (Birla white or equivalent) complete all as specified and directed.

120

-

-

... More
M&L preparation of old surfaces of wall and applying two coats of oil bound distemper over 3mm thick wall care putty (Birla white or equivalent) complete all as specified and directed.

240

-

-

... More
M&L preparation of old plastered surfaces of Ceiling and applying two coats of white wash complete all as specified and directed.

50

-

-

... More
M&L preparation of newly plastered surfaces of ceiling and applying three coats of white wash on ceiling complete all as specified and directed.

30

-

-

... More
M&L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete including 20 mm thick screed bed in cement mortar (1:6) complete all as specified and directed.

42

-

-

... More
M&L for Machine cut Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete including 15 mm thick backing coat in cement mortar (1:3) complete all as specified and directed.

5

-

-

... More
Taking down chowkhats or frame not exc 1.50 sqm each with shutter (without taking off shutters from the frame) complete all as specified and directed.

28

-

-

... More
S&F steel window with side hung shutter, including box type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified.

25

-

-

... More
S&F steel window with side hung shutter, including box type hinges with steel handle, and steel peg stay, complete without glazing bars, dovetailed or welded complete all as specified.

25

-

-

... More
S&F steel ventilator with top hung shutter including hinges, steel peg stay, complete complete all as specified and directed.

8

-

-

... More
S&F steel window or ventilator fixed type with glazing bar complete complete all as specified and directed.

8

-

-

... More
S&F galvanised mild steel wire cloth 0.63 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks or galvanised wire staples complete all as specified and directed.

18

-

-

... More
S&F 4 mm thick figured glass, pin head type and glazing with oil putty in square not exc 0.50 sqm in each pane complete all as specified and directed.

18

-

-

... More
M&L preparation of new steel surfaces of any description over 10 cm width or girth not otherwise described and applying two coat of synthetic enamel paint over a coat of red oxide complete all as specified and directed.

116.58

-

-

... More
M&L preparation of old steel surfaces of any description over 10 cm width or girth not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed.

20

-

-

... More
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm single side prelam PVC sheet used reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing.

30

-

-

... More
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles a PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; t both side Prelam PVC sheet used instead of Plaincolour PVC sheet. Stile and rails feathered at edges beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing.

19

-

-

... More
S&F 100 mm size butt hinges, medium weight , cold rolled, mild steel complete all as specified and directed.

24

-

-

... More
S&F of 100 mm long aluminium, anodised, barrel tower bolt, of extruded section and fixed all as specified and directed.

16

-

-

... More
S&F 125 mm size Aluminium handles, cast type, anodised and fixed all as specified and directed.

16

-

-

... More
Demolition of reinforced concrete of any description and in any position not otherwise specifically provided for including cutting of reinforcement as required to facilliate demolition complete all as specified and directed.

1

-

-

... More
M&L for reinforced cement concrete type B1 (1:2:4) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.

1

-

-

... More
Use & Waste of formwork to sides and soffits of shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc complete all as specified and directed.

5

-

-

... More
S&F of TMT bars 10 mm dia and over, cut to length , bent to shape required , including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, complete all as specified and directed.

146.05

-

-

... More
S&F of TMT bars 6 mm to 8 mm dia, cut to length , bent to shape required , including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, complete all as specified and directed.

15

-

-

... More
M&L mild steel bars 5 mm dia and over upto and including 10 mm dia in stirrups spacers and binders complete all as specified and directed.

62.46

-

-

... More
S&F in repairs sinks made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or includingfixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm complete all as specified and directed.

4

-

-

... More
S& F Stainless Steel Sink mixure, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for 15mm bore iron pipe and fixed complete all as specified and directed. Make : Jaquar or equivalent as approved by GE. Make : Jaquar or equivalent as approved by GE.

4

-

-

... More
S&F in repairs kitchen plate rack made out of stainless steel 0.50 mm thick sheet with partitions and size of rack 800 x 250 x900 mm with shape and pattern as per sample kept in Sample room of GE Office complete all as specified and directed.

4

-

-

... More
S&F in repair stainless steel wire cloth 0.36mm nominal dia if wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.

5

-

-

... More
M & L for Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over screed bed or bedding layer of mortar 20 mm thick for laying floor finishes in cement plaster (1:6) complete all as specified and directed by Engr - in - Charge.

14.04

-

-

... More
S&F in repairs 25mm dia curtain rod (curtain rails), alumunium alloy, powder coated with and including decorattive knobs etc complete all as specified and directed.

20

-

-

... More
M/L for 15mm thick rendering in CM (1:3) on other than fair faces of brick or concrete surfaces finished even and smooth with WPC.(WPC measured separately).

27

-

-

... More
Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar (1:3) and filling the grove with cement mortar (1:3) after tucking the felt and finishing/making good distrubed surface as required complete all as specified and directed.

10

-

-

... More
M & L for Wire brushing and cleaning top surface of tiles, lime terracing or cement concrete, including flashings and junction of parapets, etc., and surface painting, with a layer of blown grade bitumen of any penetration applied hot @ 1.7 kg per sqm complete all as specified and directed.

27

-

-

... More
M & L for water proofing treatment with 3mm thick APP based polymeric membrane minimum weighing 3 kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application complete all as specified.

27

-

-

... More
Taking down cement plaster on brick or stone masonry surfaces of walls etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.

27

-

-

... More
M&L for dismantling of existing water closet after disconnectiing the flush pipe, demolition of entire floor upto bottom of sunken portion, removing debries cleaning the top of the RCC slab in sunken portion incl peripheral surfaces and plastered with 10mm thick cement & sand mortar (1:3) using WPC finished even and smooth without using extra cement cured properly and allowed to dry and applying two or more coats of epoxy resin/polymer modified cementatious coating like brush bond of Fosroc or equivalent both on floor and wall surfaces applied as per manufacturers instructions and plastering the treated surfaces (after testing)for water tightness) 15mm thick with CM (1:3) with WPC incl providing 20mm dia GI spout with 300 mm projection beyound outer face of wall complete all as specified and directed.

2

-

-

... More
Demolition and breaking up old broken , PVC (SWR) , Cast Iron, AC, SWG soil waste and vent pipe of 75/110 mm bore including accessories set in cement mortar and removing rubbish from site as directed by Engineer-in-Charge complete all as specified and directed.

30

-

-

... More
S&F of 110 mm PVC (SWR) drain pipe single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.

20

-

-

... More
S&F of 75 mm PVC (SWR) drain pipe single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.

10

-

-

... More
S&F of 110 mm bore PVC (SWR) bend any radius with access door complete all as specified and directed.

2

-

-

... More
S&F of 75 mm bore PVC (SWR) bend any radius with access door complete all as specified and directed.

2

-

-

... More
S&F of 110 mm bore PVC (SWR) junction single (Single T) equal or unequal with access door jointing with solvent cement complete all as specified and directed.

2

-

-

... More
S&F of 75 mm bore PVC (SWR) junction single (Single T) equal or unequal with access door jointing with solvent cement complete all as specified and directed.

2

-

-

... More
S&F of 110 X 75 mm bore PVC (SWR) reducer including jointing with solvent cement complete all as specified and directed.

2

-

-

... More
S&F in repairs bevelled edge mirror of selected quality glass, of any size mounting on 6 mm thick AC building board or commercial ply wood and fixed to wooden plugs with chromium plated brass screws and cup washers, with and including aluminium edging around of mirror complete all as specified and directed.

4

-

-

... More
S&F in repairs Brass chromium plated shower rose with or without swivel joints 125 mm size including fixing to steel pipe or union complete all as specified and directed.

4

-

-

... More
S&F in repair 15 mm bore PVC connection 450 mm long with two brass chromium plated brass nuts and PVC washers complete all as specified and directed.

8

-

-

... More
S&F in repairs angle stop valve 15 mm bore, chromium plated, fancy type, with wall flange, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.

8

-

-

... More
S&F in repair 15 mm bore chromium plated bib tap fancy type with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed.

4

-

-

... More
S& F Brass CP Basin mixure, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for 15mm bore iron pipe and fixed complete all as specified and directed. Make : Jaquar or equivalent as approved by GE.

4

-

-

... More
S&F in repairs brass chromium plated tubular towel rail of 20mm dia D' type 60cm long between flanges complete all as specified and directed.

4

-

-

... More
S&F in repairs sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed.

4

-

-

... More
S&F in repairs Soap dish, CP, fixed to plugs with chromium plated brass screws complete all as specified and directed.

4

-

-

... More
S&F in repairs Grating doom 100mm dia complete all as specified and directed.

12

-

-

... More
S&F in repairs PVC low level flushing cistern 10 Ltr capacity, valveless syphonic action type complete with inlet, ball valve, float valve, bends brackets, rawl plug, brass screws handle etc complete having BIS description mark with IS-2731 with and including suitable size of MS brackets, plug, screw all as required incl taking down existing high level/low level flushing cistern any type disconnecting pipes and jointing with new one etc, and making good the floors/walls as per existing floor finish/wall finish including 32 mm bore PVC flush pipe and jointing with water closet of any type all as specified and directed.

4

-

-

... More
S&F in repairs water closet (squatt pattern) of vitreous china squatting pan of pattern "ORRISA" pattern size 580 x 440 mm white with integral foot rests (excluding flushing cistern and flush pipe) including connection to trap and flushing pipe anti syphonic pipe etc complete including trap set in and including necessary lean cement concrete complete all as specified and directed.

2

-

-

... More
S&F Vitrous china wash down water closet pan pedestal pattern white, exlcuding fixing bolts, flushing cistem & Flush pipe including PVC Seat Cover white recess bottom type mild steel chromium plated or aluminium hanging device complete all as specified and directed including dismantling existing EWC. Make Hindware, Jaquar or equivalent.

2

-

-

... More
S&F Vitreous China wash basin, flat back, size 450x300mm white, excluding taps, waste, chain and plug and porcelain stopper but including brackets complete all as specified and directed.

4

-

-

... More
Cutting chases, pinning in, making good to facings where required and pointing in cement mortar (1:3) to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting exceeding 20cm girth complete all as specified and directed.

10

-

-

... More
S&F in repairs 75 mm size PVC (SWR) floor trap plain with grating including jointing with solvent cement complete all as specified and directed.

12

-

-

... More
Taking up or down 15 mm bore old steel tubing and connections, including disconnection of fittings from tubing including cleaning for re-fixing or removal from site complete all as specified and directed.

40

-

-

... More
S&F of 15 mm bore tubes medium grade galvanised with and incl all GI fitting (such as bends, elbows, Tees, connectors, short pieces, back nuts, unions, caps and plug etc ) and fixed complete to wall and ceiling or laid in/on floor complete all as specified and directed.

40

-

-

... More
Taking down chowkhats or frame not exc 1.50 sqm each with shutter (without taking off shutters from the frame) complete all as specified and directed.

4

-

-

... More
S&F 35 mm thick second class hard wood , plain, framed panelled shutters (any number of panels), with panels of 12 mm thick timber flat on both sides (feather edged), or of 12mm thick veneered particle board medium density wood particle board with commercial face veneers complete all as specified and directed. (Note :- The dimension of the various components or parts of shutters shall be as specified in clause 8.24 (a) of MES SSR 2009 Part I)

8

-

-

... More
M&L preparation of old wood or wood based surfaces of any description over 10 cm width or girth not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed.

30

-

-

... More
M&L preparation of new wooden surfaces of any description over 10 cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.

10

-

-

... More
S&F of 150 mm long aluminium, anodised, barrel tower bolt, of extruded section and fixed all as specified and directed.

8

-

-

... More
S&F 150 mm size Aluminium handles, cast type, anodised and fixed all as specified and directed.

8

-

-

... More
S&F of 300 mm long aluminium alloy, anodised sliding door bolts with haps staple(bolt type), and fixing clips of sheet, cast or extruted sections and fixing bolt and sliding bolts of extruted sections or cast aluminium alloy and fixed complete all as specified and directed.

4

-

-

... More
S&F 2nd class hard wood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered , put together with glue, pinned at joints complete all as specified and directed.

0.13

-

-

... More
Excavation in trenches, nexc 1.5 m wide and nexc 1.5 m in depth, for foundation,etc or for shafts,wells ,cesspits,manholes,pier holesetc nexc 10 sqm on plan and iexc 1.5 m in depth and getting out in soft soil complete all as specified and directed.

3.16

-

-

... More
Excavation in trenches, nexc 1.5 m wide and nexc 1.5 m in depth, for foundation,etc or for shafts,wells ,cesspits,manholes,pier holesetc nexc 10 sqm on plan and iexc 1.5 m in depth and getting out in hard/dense soil complete all as specified and directed.

7.8

-

-

... More
M&L for PCC type D2 (1:4:8) (40 mm graded aggregate) in foundation,filling and mass concrete complete all as specified and directed.

1.78

-

-

... More
M&L for RCC (Nominal Mix) Type B1, (1:2:4) (20 mm graded aggregates) in foundation, including ,rafts,footing, foundation beams,plinth beams, bases for columns,etc basement slabs under reamed piles and mass concrete. Complete all as specified and directed.

0.88

-

-

... More
M&L for RCC (Nomial Mix) Type B1 (1:2:4) (20 mm graded aggregates) in column, pillars, piers, posts and struts. Complete all as specified and directed.

1.06

-

-

... More
Use & waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for fair finished surfaces. Complete all as specified and directed.

12.72

-

-

... More
Use & waste of formwork to sides of pillars, posts, struts, piers, columns and stanchions for fair finished surfaces. Complete all as specified and directed.

10.56

-

-

... More
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. Complete all as specified and directed.

11.21

-

-

... More
Removing excavated material n.exc. 50m and depositing where directed at a level n.exc. 1.5 m above the starting point. Complete all as specified and directed.

10.44

-

-

... More
M & L for Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing. Complete all as specified and directed.

579.69

-

-

... More
Surface dressing n exc 15 cm deep and getting out in soft/loose soil all as specified and as directed (Including Site Clearance).

49.5

-

-

... More
Excavating in post holes (or similar holes) each n.exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance n exc 50 m and making good surface complete all as specified and directed.

17.6

-

-

... More
M&L for PCC (1:3:6) type C-2 (40mm grade aggregate) in foundation of post holes complete all as specified and directed.

4.92

-

-

... More
S & F mild steel angle iron for post and struts in fencing including cutting tops to shape as dircted, drilling holes, notching for wire etc. flat iron flillets (for securing wire mesh etc.) including all necessary drilling, bolding or riveting , etc and similar work conforming to Fe-290 Gde E-165 all as directed and specified.

439.74

-

-

... More
Supply only chain link MS galvanisd fencing, any size or type wt n.exc 4 Kg per Sqm. Complete all as specified and directed.

273.74

-

-

... More
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire all as directed and specified.

69.3

-

-

... More
Supply only for mild steel round bar of Fe-410-W (grade. E-250 quality-A or Fe 290) (Gde E-165), 10mm dia as in line wire complete all as specified and directed.

81.18

-

-

... More
S & F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long 11 to 15mm complete all as specified and directed.

7.76

-

-

... More
M & L for Preparation of new steel surfaces of any description n exc10cm in width and applying two coat of synthetic enamal paint over a coat of red oxide zink chrome primer complete all as specified and directed.

13.2

-

-

... More
S & F Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured)

1.32

-

-

... More
M & L for PCC (1:3:6) type C-2 (using 40mm graded agg) as in foundations, filling and mass concrete complete all as specified and directed.

1.69

-

-

... More
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and directed.

28

-

-

... More
M & L for brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in CM (1:4) complete all as specified and directed.

8.5

-

-

... More
M & L for brickwork with flyash bricks, straight or curved on plan to any radius in half brick thick walls, built in CM (1:4) complete all as specified and directed.

3.6

-

-

... More
M & L for 15mm thick rendering in CM (1:6) on brick masonry surfaces or surfaces other than fair faces of brick work, rendering finished even and smooth (without using extra cement) complete all as specifed and directed.

27

-

-

... More
M&L for hard core of broken boulder n.exc 63 mm, deposited, spread and levelled in layers n.exe 15 cm thick, watered and rammed to a true surface. Complete all as specified and directed by Engr-in-Charge.

3.3

-

-

... More
M& L for PCC (1:4:8) type D2 (40mm graded aggregate) 100mm thick as in sub base. Complete all as specified and directed by Engr-in-Charge.

19.75

-

-

... More
M & L for 100mm thick PCC (1:2:4) type B-2 (using 40mm graded aggregate) as in flooring and finishing cement concrete surface even and smooth with using extera cement. Complete all as specified and directed.

19.75

-

-

... More
M & L for 75mm thick PCC (1:3:6) type C-2 using 40mm graded stone agg as in plinth protection/path laid slope of 1 in 12 and finishing cement concrete surface even and smooth without using extra cement with and including all necessary formwork to divide the area in panels, finishing exposed edges fair or rounding or chamfering of exposed edges or as directed by Engr-in-Charge.

15

-

-

... More
M & L for forming construction joints 30mm deep x 10mm wide, filled with sealing compound grade 'A'. Complete all as specified and directed by Engr-in-Charge.

1

-

-

... More
S & F mild steel work in tubular tresses, purlins including special shaped washer etc. compolete using ERW or induction butt welded tubes conforming to I.S 1161-1979 grade St. 240 as in frame work for sun shade, roof, projection etc. Complete all as specified and directed.

465

-

-

... More
S&F Pre- painted galvalume aluminum zinc coating GI based steel sheet (AZ 70) of approved profile of corrugation, 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws all as specified and directed by Engr-in-Charge.

32

-

-

... More
M & L for preparation of new plastered surfaces of wall and applying two coats of cement base paint. Complete all as specified and directed.

27

-

-

... More
Taking down unserviceable copper/aluminium point wiring of any description including all fittings (switch , socket, switch socket combination, lamp holder, ceiling rose, regulator etc.) and making good disturbed surfaces of wall, floor etc. to match with existing finishes complete all as specified and as directed.

116

-

-

... More
Dismantling and taking down unserviceable main switches, DBs including sub main wiring etc. any type / size and making good disturbed surfaces to match with the existing finishes complete all as specified and as directed.

5

-

-

... More
Material and labour for point wiring with 1.5 Sqmm (nominal area) PVC insulated un - sheathed single core multi stranded copper conductor FRLS cable 1100 volts grade (conforming to IS) drawn through and including rigid non metallic PVC conduit not less than 20mm dia, medium grade with all necessary fittings, Concealed wiring , for light /Bell point controlled by one switch including 1.5 Sq mm PVC insulated copper stranded conductor for earth continuity conductor and connected to earth dolly and to be terminated in 1.6 mm thick pressed steel terminal boxes/ on PVC Boxes (concealed type in permanent bldg and surface in temporary bldg or as directed ) for mounting fittings like switch, socket, fan regulator etc. with 3 mm thick laminated bakelite sheet cover ,for housing switches, socket outlet, regulator etc. complete all as specified or directed including testing on completion.

63

-

-

... More
All as per item No.130 here-in-before but One bell point controlled by one switch all as specified and as directed.

4

-

-

... More
All as per item No.130 here-in-before but One 3 pin socket outlet 5/6 Amps on the same board with other switchs with cables 1.5 Sqmm size all as specified and as directed.

16

-

-

... More
All as per item No.130 here – in – before but for one 3 / 5 -pin switch socket outlet 5/6 amps on independent board all as specified and as directed.

20

-

-

... More
All as per item No.130 here – in – before but for one switch socket outlet 15/16 Amps on independent board with 2.5 Sqmm multi stranded and 2.5 Sq mm stranded (for earth) PVC insulated un-sheathed copper cable all as specified and as directed.

16

-

-

... More
Supply and fix Bell push button 5 Amp, flush type all as specified and as directed.

4

-

-

... More
Supply and fix Bell, Ding Dong electric AC 230 Volts single pole complete all as specified and as directed.

4

-

-

... More
Supply and fix switch piano flush button, single pole, 5/6amps, one way all as specified and as directed.

63

-

-

... More
Supply and fixing lamp/angle holder insulated body with back plate for batten fitting all as specified and as directed.

12

-

-

... More
S & F in LED retro fit lamp B-22 holder base with poly carbonate body and aluminium heat shrink of 9W complete CAT Part No : LHLDDBEBBI8R009 of havells or Equivalent of Crompton/Philips.

24

-

-

... More
Supply and fix switch socket combination 2 – in – one, 3 Pin / 5 Pin, 5/6 amps flush type all as specified and as directed.

36

-

-

... More
Supply and fixing switch socket combination 2 – in – one 6 Pin , 6 / 16 amps flush type universal all as specified and as directed.

16

-

-

... More
Supply & Fixing ceiling rose surface bakelite 65 X 50 mm three terminal all as specified and as directed.

28

-

-

... More
Supply and fixing LED tube lights fitting, 4 feet long 1x 18W, 220V, AC decorative box type with holder including Removable poly cabonate LED tube light with inbuilt driver connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.

24

-

-

... More
Supply and fixing Decorative, wall mounting, made up of Polycarbonate body suitable for 10 W LED lamp (B-2 base), Cat part No LHDL06160099 Model CITY - 3 Make- Havells or equivalent model of Philips/Bajaj / Crompton.

12

-

-

... More
Supply and fixing LED building security light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed.

2

-

-

... More
S & F LED light fitting 1x9W/1X10W IP66 & IK09 integral LED Bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size including taking down old unserviceable fitting complete all as specified and as directed.

6

-

-

... More
Supply and fix New generation, IP 65 LED post-top family, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source. Complete all as specified or directed. Make- Havells Cat Part No : CORALMINIPT15WLED830PSYMTOPC or equivalent Philips, Crompton.

3

-

-

... More
S&F metal plug socket single pole and neutral encloser with two pin earth plug with 01 No MCB SP 20 Amp, C series complete all as specified and as directed.

4

-

-

... More
S&F TPN DB with suitable for TPN MCB incomer, double door (IP-54), 4 Ways, built- in 200 Amps busbar for neutral link complete suitable for 415 Volts, AC, 50 Hz, concealed in wall complete all as specified and as directed.

1

-

-

... More
Supply and fixing Sheet metal enclouser Double door for MCB DB,s Phosphatised Powder Painted with bus bar 200 Amps rated Single pole and neutral linkof 8 way 240 Volts AC, concealed in wall complete all as specified and as directed.

1

-

-

... More
Supply and fixing 415V 10KA 'C' curve miniature circuit breaker (MCB) of TPN 40 To 100 AMP in the DB complete with connection testing and commissioning all as specified and directed.

1

-

-

... More
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of SPN 40 to 63 AMP and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and as directed.

8

-

-

... More
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of SP 5 To 32 AMP and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and as directed.

24

-

-

... More
M&L in repairs for sub main wiring along with earth wire of size two run of 4 sq mm + one run of 4 Sq mm earth wire single core PVC insulated cable with stranded copper conductor FRLS including drawing into 25 mm rigid non-metalic PVC conduit concealed in wall/roof .(Note Three run of 4 Sqmm including one run of 25 mm rigid non-metalic PVC conduit shall be measured as one unit length including taking down of old servicible sub main wiring complete all as specified and as directed.

40

-

-

... More
M&L in repairs for sub main wiring along with earth wire of size two run of 6 sq mm + one run of 6 Sq mm earth wire single core PVC insulated cable with stranded copper conductor FRLS including drawing into 25 mm rigid non-metalic PVC conduit concealed in wall/roof .(Note Three run of 6 Sqmm including one run of 25 mm rigid non-metalic PVC conduit shall be measured as one unit length including taking down of old servicible sub main wiring complete all as specified and as directed.

70

-

-

... More
M&L for sub main wiring along with earth wire of size two run of 1.5 sq mm + one run of 1.5 Sq mm earth wire single core PVC insulated cable with stranded copper conductor FRLS including drawing into 25 mm rigid non-metalic PVC casing caping on surface of wall/roof .(Note Three run of 1.5 Sqmm including one run of 25 mm of size casing caping shall be measured as one unit length) complete all as specified or directed.

30

-

-

... More
Supply and Fixing in repairs exhaust fan, steel body AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers including fixing arrangement, complete all as specified and directed.

4

-

-

... More
Supply and fix in repairs electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc including taking down old u/s Geaser & deposit to MES Store complete all as specified and directed.

4

-

-

... More
Taking down Electric KWH meter and keep in safe custody and refixing the same as including necessary electric connection from main to KWH meter and KWH meter to out going distribution board.

4

-

-

... More
Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm buried directly in ground ( earth pit not less than 2.25 m deep bellow ground level ) with top edge of the plate not less than 1.5 m bellow normal ground level, connected to galvanized earth lead wire 4 mm dia. by means of galvanized iron or steel bolts , nuts , check nuts and washers, and connected to equipments as directed , including funnel with GI med grade watering pipe 20 mm bore , wire mesh , charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode , with concrete pit in PCC (1 : 3 : 6) type C-1 , 50 mm thick pre cast RCC (1 : 2 : 4) type B-1 cover slab reinforced with 8 mm dia deformed bar 15 cm C/C and suitable handle of 10 mm dia round bar ,GI medium grade pipe for earth lead protection including necessary excavation earth work in soft/loose soil and disposal of spoil to a distance n.exc. 50 m and necessary testing complete all as shown on electrical plate No. 5 of MES SSR Part-I and as directed.

2

-

-

... More
Material and labour for cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armored, electric power cables (heavy duty 1100 Volts grade with stranded aluminium conductor of size 25Sqmm 3.5 Core, including glands, lugs, nut, bolts, washers as required at site, testing complete all as specified and directed.

3

-

-

... More
Excavation in trenches/ foundation in soft/ loose soil not exc. 1.5 metre wide and n'exc. 1.50m deep for LT under ground cable/pole foundation and getting out including forming bottom surface to required level or slope, complete all as specified and directed by Engineer-in- Charge.

4

-

-

... More
Sand cushioning to underground cables provided with a layer of sand 8cm thick before laying the cable in trenches and 15cm thick after laying the cable in trenches complete all as specified.

5

-

-

... More
M&L Sub class ‘B’bricks for covering to cable laid dry flat ,with width equal to the length of brick.

6

-

-

... More
S & F Steel pipe glavanized light grade of 40 mm dia laid in trenches or under ground/floor or road of fixed with pole for protection of cable/ Earth sstrip including clams with bolts nuts and wasers complete ass as specifed.

7

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.