Military Engineer Services Tender
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.
Military Engineer Services - MES Tender
Civil And Construction
Pipe Line Project
Eprocure
Opening Date30 May 2023
Closing Date27 Jun 2023
Tender Amount₹ 44,00,000
Costs
EMD
₹ 88,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_MES_599617_1Bid Award Id
ViewTender No
8223/SEV OF 2023-24Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Taking up or down 25 mm bore steel tubing and connections including cleaning for re-fixing or removal to store complete all as specified.
180
-
-
... More
Demolition of brick coba/cement concrete (unreinforced) from existing roof/terrace etc and also removing/taking down of existing water proofing treatment of any thickness in any position including cleaning the surfaces of roof etc with wire brush complete and removing the retreived debris in low lying area, complete all as specified and directed.
2.5
-
-
... More
Dismantling PVC water tanks from the position of 1000 ltrs capacity complete all as directed.
20
-
-
... More
Dismantling PVC water tanks from the position of 500 ltrs capacity complete all as directed.
45
-
-
... More
Dismantling floor hearth or wall tiling including cement mortar bedding ( but not backing ) removing serviceable tiles to store and rubbish off the premises etc complete all as specified and directed.
1624.5
-
-
... More
Dismantling steel sheeting or galvatume aluminium zinc of any gause thickness (plain) (corrugated semicorrugated) in roof coverings etc complete all as directed.
420
-
-
... More
Demolition of brick work built in cement mortar including all quoins, arches, pillars etc complete all as specified.
8.8
-
-
... More
Demolition of reinforced cement concrete work (RCC water tank) of any description and in any position not otherwise specifically provided for all as specified.
4.15
-
-
... More
M&L for brick work with sub class 'B' bricks using old size bricks straight or curved on plan exc 6 mtr mean radius built in CM 1:6 complete all as specified.
6.75
-
-
... More
M&L for brick work with sub class "B" bricks straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified.
18
-
-
... More
M&L for 10mm thick rendering on other than fair faces of brick or concrete surfaces in CM 1:6 finshed even and smooth without using extra cement complete all as specified.
160
-
-
... More
M&L for rendering 5 mm thick in CM 1:3 as in ceilingfinished even and smooth without using extra cement complete all as specified..
40
-
-
... More
M&L for 20 mm thick rendering in CM 1:4 in two layers of 10mm each using water proofing compound in top layer only including finishing the surface even and fair(WPC shall be measured and paid seperately) complete all as specified and as directed.
200
-
-
... More
M&L for preparation of new plastered surfaces of walls and applying two coats of oil bound distemper over a coat of primer over 1 mm thick wall putty complete all as specified and directed. .
160
-
-
... More
M&L for preparation of new plastered surfaces on ceiling and applying three coats of white wash etc complete all as specified and directed
40
-
-
... More
M&L for preparation of new plaster surface of walls and appling two coats of weather coat Ultima exterior paint (first quality) of required shade over a coat primer and over 1 mm thick wall putty complete all as specified and directed.
200
-
-
... More
Supply only water proofing compound (integral) complete all as specified and directed.
110.22
-
-
... More
S&F 15 mm bore medium grade galvanized steel water tubing with all fittings and fixed to wall/ceiling or laid in floor complete all as specified and directed.
300
-
-
... More
S&F 20 mm bore medium grade galvanized steel water tubing with all fittings and fixed to wall/ceiling or laid in floor complete all as specified and directed.
200
-
-
... More
S&F 25 mm bore medium grade galvanized steel water tubing with all fittings and fixed to wall/ceiling or laid in floor complete all as specified and directed.
140
-
-
... More
Fixing only 15 mm bore tubing with all fittings and fixed to wall/ceiling or laid in floor complete all as directed.
80
-
-
... More
Fixing only 20 mm bore tubing with all fittings and fixed to wall/ceiling or laid in floor complete all as directed.
50
-
-
... More
Fixing only 25 mm bore tubing with all fittings and fixed to wall/ceiling or laid in floor complete all as directed.
40
-
-
... More
M&L forpreparation of wall surface and appling two coats of weather coat Ultima exterior paint (first quality) of required shade over a coat of exterior primer and 1 mm thick wall putty complete all as specified and directed.
200
-
-
... More
M&L for cutting out cracks to V-section in existing roofs or terracing, cleaning out, wetting, grouting with cement and sand slurry 1:3
160
-
-
... More
M&L for cement concrete type D2, 1:4:8, using 40 mm graded aggregate in basement for foundations to PVC water tank, filling etc complete all as specified and as directed.
4.5
-
-
... More
M&L for 25 mm thick PCC (1:2:4) type B-0, using 12.5mm graded stone aggregate as in levelling course over RCC roof surface to achieve required slope including making rounded or chamfered on edges mixed with WPC @2% by weight of cement, complete all as specified and directed. Note : WPC shall be measured and paid separately as supply only.
250
-
-
... More
M&L for 15mm thick rendering in CM (1:4) over RCC roof surface to receive roof treatment finished even and smooth without using extra cement mixed with water proofing compound as per manufacturers instruction (WPC shall be measured and paid separately).
250
-
-
... More
M & L for surface preparation including cleaning the surface , treating of construction joints , filling of honey combs with polymer modified mortar (cement:sand: approved polymer(asian/beger) for filling cracks up to 3mm use approved crack seal, bigger cracks, damaged potions and hollow areas must be repaired with polymer modified cement mortars complete as specified and as directed.
250
-
-
... More
M&L for applying water proofing treatment to slab area with damp proof ultra, fiber reinforced elastomeric liquid applied water proofing membrane of apporoved make(Asian/Berger/Dr Fixit) . It is formulated with PU hybrid polymers and reinforcing acrylic fibers. Upon curing, it forms a thick, seamless, durable membrane thus offering ultimate water proofing. First do the self priming of smart care damp proof ultra of approved make after completing all necessary surface preparation, coving using approved smart care repair polymer, water pond test, etc complete as per manufacturers specifications and application methodology. The same coating shall be applied in two coats with 4-6 hrs intervals between the coats. Ensure that the product is applied at least 6 inches inside the drain pipe. The coating shall have a 350%-400%elongation with tensile strength of 2.9 Mpa and must be extended up to 300 mm over the slab area and apply parapet to parapet to envelop the entire biulding. Effectively bridges cracks up to 2.5 mm at 650 microns and provides surface temperature reduction up to 10 degree C. Complete all as specified and directed as per manufacturers instruction and submit roof water proofing warranty certificate of 8 years from the manufacturer.
250
-
-
... More
Treatment of sunken floor slab compraises of the following specifications and all as specified.:-(Ser No 29.01 to 29.09)
25
-
-
... More
(i) M&L for cleaning the sunken/ lowered portion of RCC slab surface (including vertical total depth plus skirting height ) of floors by wire brush, chisel out any mortar sticking to the surface and brooming completely . 40mm thick avg PCC 1:2:4 type B-0 using 12.5mm graded aggregate as in padding conc to achieve proper slope including 50mm PVC pipe and cutting holes in bricks or RCC wall for spout.
-
-
-
... More
(ii) Rendering of uneven surfaces with 6mm thick CM 1:4 mixed with integral water proofing compound @3% by wt of cement consumed. Fill it with water and check dampness and seepage. Where dampness/ seepage is noticed , nozzles shall be fixed and grouting carried out (WPC shall be measured and paid separately )
-
-
-
... More
(iii) All junctions points of side wall where CI/GI pipes are passing through shall be sealed with epoxy putty
-
-
-
... More
(iv) After drying putty , wash the slab and sides of sunken portion with water and make it clear and clean.
-
-
-
... More
(v) M&L for applying two coats of polymer modified cementious water proof coating as per manufacturs instruction to bottom and vertical sides up to finished floor level +100mm height . The thickness of two layer shall be 1mm . When the second layer is still sticky, coarse sand spray shall be carried for the vertical and bottom surface of the sunken portion all as specified and directed.
-
-
-
... More
(vi) Plaster the bottom and sides up to bottom of the skirting with minimum 20mm thick CM 1:4 mixed with integral water proofing compound 3% by wt of cement consumed as per menufacturer's specification including rounding of corners and junctions sloping towards spout ( WPC Shall be measured & paid separately)
-
-
-
... More
Note :- Test the water proofed area (ponding test ) by filling water for at least 72 hours and tested for leakage seepage and to the entire satisfaction of GE . Test shall be done in presence pf reps of PMG and record for each sunken slab shall be maintained. The treatment shall be carried out by authorised applicators of chemicals. Cost of testing in inclued in the rates quoted above.
-
-
-
... More
(vii) All pipes laid in sunken portion shall be covered with 50mm thick PCC 1:3:6 all round after painting with anticorrosive paint (Black Japan)
-
-
-
... More
(viii) Two nos 50mm bore GI medium grade 600mm long spout shall be provided through external wall to drain out accumulated water.
-
-
-
... More
Disconnecting existing tanks 500 ltrs capacity, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required econnecting and re-fixing in position incl cleaning.
40
-
-
... More
Disconnecting existing tanks 1000 ltrs capacity, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required econnecting and re-fixing in position.
20
-
-
... More
S&F rotational moulded polyethylene water storage tanks, triple layered(ISI marked) of 500 ltrs capacity(cylinderical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I, including provision of necessary fittings for connection the overflow, drain out, inlet and outlet pipes, complete all as specified and as directed.
45
-
-
... More
S&F rotational moulded polyethylene water storage tanks, triple layered(ISI marked) of 1000 ltrs capacity(cylinderical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I, including provision of necessary fittings for connection the overflow, drain out, inlet and outlet pipes, complete all as specified and as directed.
20
-
-
... More
S&F in repairs Ball brass valves of size 25 mm bore high pressure, the polythene float and fly nut, screwed for iron pipe or brass frame etc, complete al as specified and directed.
80
-
-
... More
S&F in repairs Ball brass valves of size 20 mm bore high pressure, the polythene float and fly nut, screwed for iron pipe or brass frame etc, complete al as specified and directed.
80
-
-
... More
M&L for non skid coloured ceramic tiles of 7 to 8 mm thick (square/rectangular) area exceeding 0.11sqm but not exceeding 0.18 sqm in floor etc set and jointed in neat cement slurry and pointed in coloured cement to match with the shade of tiles over and including 15 mm thick screed bed or beding layer of CM 1:6 for laying of floor finises complete all as specified and as directed
300
-
-
... More
M&L for non skid coloured ceramic tiles of 7 to 8 mm thick (square/rectangular) area Exceeding 0.11sqm but not exceeding 0.18 sqm in skirting etc set and jointed in neat cement slurry and pointed in coloured cement to match with the shade of tiles over and including 10 mm thick rendering as backing layer in CM 1:4 complete all as specified and as directed
60
-
-
... More
M&L for non skid coloured ceramic tiles of 7 to 8 mm thick (square/rectangular) area exceeding 0.18sqm but not exceeding 0.38 sqm in floor etc set and jointed in neat cement slurry and pointed in coloured cement to match with the shade of tiles over and including 15 mm thick screed bed or beding layer of CM 1:6 for laying of floor finises complete all as specified and as directed
480
-
-
... More
M&L for non skid coloured ceramic tiles of 7 to 8 mm thick (square/rectangular) area Exceeding 0.18sqm but not exceeding 0.38 sqm in skirting etc set and jointed in neat cement slurry and pointed in coloured cement to match with the shade of tiles over including 10 mm thick rendering as backing layer in CM 1:4 complete all as specified and as directed
96
-
-
... More
M&L for glazed coloured ceramic tiles of size 450x350x 7mm thickness in vertical surfaces set and jointed in neat cement slurry and pointed in coloured cement to match with the shade of tiles on wall over and including 10 mm thick rendering as backing layer in CM 1:4 complete all as specified and as directed.
688.5
-
-
... More
M&L for PVC (SWR) floor trap/nahani trap, plain with grating including jointing with solvent cement complete all as specified and as directed.
80
-
-
... More
S&F in repairs vitreous china EWC white with 'P' or 'S' trap front or back inlet any pattern excluding flushing cistern & flush pipe but including plastic water closet seat black closed pattern with flat bottom and cover and hinging device complete all as specified and directed.
20
-
-
... More
S & F in repairs flushing cistern, 10 Ltrs. Capacity, PVC valveless, syphonic action type with dual flushing system, low level,white with inlet, ball valve,float and handle including brackets, flush pipe of polyethylene of low or high density or PVC, 32mm dia, complete all as specified and directed.
20
-
-
... More
S&F PVC connection pipe 15 mm dia, 450 mm long with PTMT nut complete all as specified and as directed
100
-
-
... More
S&F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified
90
-
-
... More
S&F in repair sheet glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified.
60
-
-
... More
S&F soap dish Chromium plated complete as specified and directed.
50
-
-
... More
S&F in repairs brass chromium plated, shower rose, 125mm size, complete all as specified and directed.
55
-
-
... More
S&F towel rail 600mm long of PTMT (min weight 190 grams) fixed with and incl chromium plated brass screws and wooden / plastic cleats, complete all as specified and directed.
60
-
-
... More
S&F Stop cock/angle cock, cast copper alloy chromium plated, screwed down, high pressure with crutch or butterfly handle, fancy type chromium plate with long shank and cup complete all as specified and directed.
60
-
-
... More
S&F 15mm bore bib tap cast copper alloy with crutch or butterfly handle, fancy type, chromium plated, screwed iron pipe or for brass ferrule complete all as specified and directed.
70
-
-
... More
S&F in repair of CP brass wall mixture 3 in 1 system with provision forhead shower with long bend pipes and wall flangs with 125mm size chromium plated shower rose with swivel joint and matching CP arm complete all as specified and directed.
10
-
-
... More
S&F pre painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550mpa as in roof covering/clading to wall, fixed with self taping screws complete all as specified and directed..
375
-
-
... More
S&F pre painted galvatume aluminium zinc coating GI based Plain steel sheet 0.50mm thick of an colour having tensile strength of 550mpa as in roof covering/clading to wall, fixed with self taping screws complete all as specified and directed...
45
-
-
... More
S & F Mild steel work in framed brackets of angles or tees with web and flanges cut to shape, drilled and counter sunken for screw, including bending and welding angles as necessary gusset plates; riving etc n'exc 10 Kg each brackets conforming to Fe-290 Gde-165 complete all as specified and directed. .
240
-
-
... More
S & F Framed work as in tubular posts roof trusses, purlines, rafters etc made of tubes (square circular oval or any other shape or section as directed) including all necessary fittings, nut bolts, threading or welding etc as required for completion of work.
1076.25
-
-
... More
M&L for applying two coat of synthetic enamel paint on newly steel surfaces exceeding 10 cm in width or girth over one coat of red oxide primer after preparation of surface complete all specified and directed
63.17
-
-
... More
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittinges, heads, shoes, bends, swan-necks etc including cleaning or refixing or removal to store (measured overall as fixed along the centre line over fittings and accessories)
120
-
-
... More
S & F 110 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified & directed.
120
-
-
... More
S & F 110 mm bore PVC (SWR) bends of any radius complete all as specified & directed.
40
-
-
... More
S & F 110 mm bore PVC (SWR) branch piece single (Single `Y') equal or unequal with access door complete all as specified & directed.
5
-
-
... More
S & F 110 mm bore PVC (SWR) branch piece double (Double `Y') equal or unequal with access door complete all as specified & directed.
6
-
-
... More
S & F 110 mm bore PVC (SWR) Vent cowl complete all as specified & directed
8
-
-
... More
S & F 75 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified & directed.
180
-
-
... More
S & F 75 mm bore PVC (SWR) bends of any radius complete all as specified & directed.
65
-
-
... More
S & F 75 mm bore PVC (SWR) branch piece single (Single `Y') equal or unequal with access door complete all as specified & directed.
10
-
-
... More
S & F 75 mm bore PVC (SWR) branch piece double (Double `Y') equal or unequal with access door complete all as specified & directed.
10
-
-
... More
S & F 75 mm bore PVC (SWR) Vent Cowl complete all as specified & directed
35
-
-
Evaluation Notes How It Works ?