Military Engineer Services Tender

Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date17 Dec 2024
Closing Soon14 Jan 2025
Tender Amount₹ 40,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
All as per item No 2.00 here-in- before but for 5 Amp socket on Independent board with other switches complete all as specified and directed.

75

-

-

... More
All as per Item No 2.00 here-in- before but for one calling bell point controlled by one one way Bell switches complete all as specified and directed.

10

-

-

... More
All as per BOQ item No 2.00 here-in-before but for one power pointt using by 4.00 sq mm FRLSH,PVC insulated multi stranded copper conductor single core cable 1100 volts grade (Red Colour use for Phase & Black Colour use for Neutral), and with and including FRLSH,PVC insulated multi stranded copper conductor single core 4.00 sq mm conductor for earth continuity (Green Colour) , on independent board ( but Not below the switch board of light points in the same vertical plane).

50

-

-

... More
Material & Labour for point wiring complete with 1.5 sq mm FRLSHH, PVC insulated multi stranded copper conductor single core cable 1100 volts grade (Red Colour use for Phase & Black Colour use for Neutral),drawn into and including PVC casing- caping (double interlock type) of not less than 20mm width with accessories and fittings such as bends, elbows, tees, crosses, junction box etc, fixed on wall/ceiling with GI saddles, GI screws, rawl plugs etc. for one light/fan/ bell point controlled by one switch including pressed steel terminal box powder coated of suitable size with 3 mm thick plastic laminated sheet cover of approved make for housing/mounting switches, sockets & regulators etc. and drawing 1.5 sq. mm copper solid conductor PVC insulated, unsheated cable as earth continuity conductor, connected to common earth and earth dolly , all as specified and directed by Engineer-in-Charge Note :- Cost of PVC casing & capping, making good disturbed wall surfaces including finishing with cement mortor 1:4, matching with existing colour/paint of surface are deemed to be included in the quoted rate.

135

-

-

... More
All as per item No 7.00 here-in- before but for 5 Amp socket on same board with other switches.

15

-

-

... More
All as per item No 7.00 here-in- before but for 5 Amp socket on Independent board with other switches.

55

-

-

... More
All as per item No 7.00 here-in- before but for one bell point with other switches.

10

-

-

... More
All as per BOQ item No 7.00 here-in-before but for one power pointt using by 2.50 sq mm FRLSH,PVC insulated multi stranded copper conductor single core cable 1100 volts grade (Red Colour use for Phase & Black Colour use for Neutral), and with and including FRLSH,PVC insulated multi stranded copper conductor single core 2.50 sq mm conductor for earth continuity (Green Colour) , on independent board ( but Not below the switch board of light points in the same vertical plane).

60

-

-

... More
Supply and fixed switch piano flush type, single pole , 5/6 Amps, one way complete all as specified and directed. (Note : Item to be measured if executed under new point wiring)

648

-

-

... More
Supply & Fixing socket outlets 2 in 1, 5/6 Amps, 230/240 V complete all as specified and as directed . (Note : Item to be measured if executed under new point wiring)

18

-

-

... More
Supply & Fixing switch 16 Amps, 230/240 V complete all as specified and as directed (Note : Item to be measured if executed under new point wiring)

50

-

-

... More
Supply and fixed socket outlet 2 in 1 , 3 pin , (16 Amps ) flush type controlled by one switch complete all as specified (Note : Item to be measured if executed under new point wiring)

50

-

-

... More
Supply & fixed ceiling rose surface bakelite 45 mm x 50 mm two to three terminal suitable for 230 Volts AC 6 Amps complete all as specified . (Note : Item to be measured if executed under new point wiring)

765

-

-

... More
Supply & fixed stepped type electronic fan regulator flush type 240 Volts ISI marked complete all as specified (Note : Item to be measured if executed under new point wiring)

30

-

-

... More
Supply & fixed Bell push , flush type , 5 amp duly marked complete all as specified (Note : Item to be measured if executed under new point wiring)

10

-

-

... More
Supply & fixed Ding dong, AC 230 Volts, single pole 230 volts all as specified and directed (Note : Item to be measured if executed under new point wiring)

20

-

-

... More
Supply & fixed lamp holder, polycarbonatebody with back plate straight or angular suitable for batten fittings complete all as specified. (Note : Item to be measured if executed under new point wiring)

65

-

-

... More
Supply & Fixing switch modular type 6 Amp one way, one module, single phase, complete all as specified and directed by Engineer-in-charge (Note : Item to be measured if executed under new point wiring)

205

-

-

... More
Supply & Fixing switch modular type 16/20 Amp one way, one module, single phase, complete all as specified and directed by Engineer-in-charge (Note : Item to be measured if executed under new point wiring)

60

-

-

... More
Supply & Fixing bell push ,modular type 6 Amp SP one way, 1 module complete all as specified and directed. (Note : Item to be measured if executed under new point wiring)

10

-

-

... More
Supply & Fixing fan regulator modular step type 120 W 2 module suitable for 230 volt AC complete all as specified and directed. (Note : Item to be measured if executed under new point wiring)

80

-

-

... More
Supply & Fixing socket outlet modular type 6 Amp 2/3 pin , two module, single phase, complete all as specified and directed by Engineer-in-charge . (Note : Item to be measured if executed under new point wiring)

70

-

-

... More
Supply & Fixing socket outlet modular type 16 Amp 2/3 pin , two module, single phase, complete all as specified and directed by Engineer-in-charge. (Note : Item to be measured if executed under new point wiring)

60

-

-

... More
Supply & fixed sheet metal enclosure with 20 Amp Mcb single pole and two pin and earth plug and socket complete with one single pole MCB all as specified. (Note : Item to be measured if executed under new point wiring)

15

-

-

... More
Supply and fixing for concealed type sub main wiring with two run of 4.00 Sqmm single core PVC FRLSH, PVC insulated unsheathed stranded copper conductor (Red/yellow/blue wires for phases and black wire for neutral) drawn in and including through Rigid non-metallic PVC conduit(medium) ISI marked of size 20mm bore with all fittings like tee/Bend/Elbow/Reducer/Bell mouth/Junction / Terminal Boxes etc. and fixing accessories such as coupler, lock nuts, saddles, pipe hook etc. including one run of 4.00 Sqmm single core PVC FRLSH, PVC insulated unsheathed stranded copper conductor as earth wire (green in colour) complete all as specified. Note : (i) Note : 2 runs of line conductor, one run of earth continuity conductor, one run of PVC conduit shall be measured as unit length. (ii) Cost of PVC conduit, conductors, making good disturbed wall surfaces including finishing with cement mortor 1:4, matching with existing colour/paint of surface are deemed to be included in the quoted rate.

385

-

-

... More
Supply and fixing for concealed type sub main wiring with two run of 6.00 Sqmm single core PVC FRLSH, PVC insulated unsheathed stranded copper conductor (Red/yellow/blue wires for phases and black wire for neutral) drawn in and including through Rigid non-metallic PVC conduit(medium) ISI marked of size 25mm bore with all fittings like tee/Bend/Elbow/Reducer/Bell mouth/Junction / Terminal Boxes etc. and fixing accessories such as coupler, lock nuts, saddles, pipe hook etc. including one run of 4.00 Sqmm single core PVC FRLSH, PVC insulated unsheathed stranded copper conductor as earth wire (green in colour) complete all as specified. Note : (i) Note : 2 runs of line conductor, one run of earth continuity conductor, one run of PVC conduit shall be measured as unit length. (ii) Cost of PVC conduit, conductors, making good disturbed wall surfaces including finishing with cement mortor 1:4, matching with existing colour/paint of surface are deemed to be included in the quoted rate.

150

-

-

... More
Supply and fixing for surface type sub main wiring with two run of 4.00 Sqmm single core PVC FRLSH, PVC insulated unsheathed stranded copper conductor (Red/yellow/blue wires for phases and black wire for neutral) drawn in and including drawn into and including PVC casing- caping (double interlock type) of not less than 25mm width with accessories and fittings such as bends, elbows, tees, crosses, junction box etc, fixed on wall/ceiling with GI saddles, GI screws, rawl plugs etc. including one run of 4.00 Sqmm single core PVC FRLSH, PVC insulated unsheathed stranded copper conductor as earth wire (green in colour) complete all as specified. Note : (i) Note : 2 runs of line conductor, one run of earth continuity conductor, one run of PVC casing caping shall be measured as unit length. (ii) Cost of PVC casing caping, conductors, making good disturbed wall surfaces including finishing with cement mortor 1:4, matching with existing colour/paint of surface are deemed to be included in the quoted rate.

320

-

-

... More
Supply and fixing for surface type sub main wiring with two run of 6.00 Sqmm single core PVC FRLSH, PVC insulated unsheathed stranded copper conductor (Red/yellow/blue wires for phases and black wire for neutral) drawn in and including drawn into and including PVC casing- caping (double interlock type) of not less than 25mm width with accessories and fittings such as bends, elbows, tees, crosses, junction box etc, fixed on wall/ceiling with GI saddles, GI screws, rawl plugs etc. including one run of 6.00 Sqmm single core PVC FRLSH, PVC insulated unsheathed stranded copper conductor as earth wire (green in colour) complete all as specified. Note : (i) Note : 2 runs of line conductor, one run of earth continuity conductor, one run of PVC casing caping shall be measured as unit length. (ii) Cost of PVC casing caping, conductors, making good disturbed wall surfaces including finishing with cement mortor 1:4, matching with existing colour/paint of surface are deemed to be included in the quoted rate.

299

-

-

... More
Supply & fixing in repair LED street light 35/36 watt (Min) 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, BIS approved silicon zel fitted potted driver with impact and corrosion resistant complete with driver and lamp, Aluminum die cast housing High efficiency long life LED package in integral module with lumen efficacy of 115 lm/W (Min) and viewing angle of 45 degree to ensure better uniformity, electronic LED driver (SMPS based constant current supply) with Output Short-circuit protection, Surge protection & other reliability test as per latest IS. LED operational voltage of 170 volts to 270 volts, frequency of 50 Hz, protection grade IP 66, IK-08 CRI greater than or equal to 70% , CW available CCT of 5700K/6500K, power factor of minimum 0.95 , life span of minimum 50000 working hours cincluding necessary electrical connections by PVC sheathed copper conductor wire of 3 core x 1.5 Sqmm and necessary fixing arrangement all as specified. Note : (i) The minimum requirement of lumen efficiency, lumen output and power consumption has been specified. However, as per availability, the bidders may opted higher specification with out any extra cost. The quoted rate is deem to be included for that and no extra payment will be made on this account. (ii) The fittings should be marked 'Date of installation" and "Date of Procurement" with marker pen.

10

-

-

... More
Supply & fixing in repair LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed

35

-

-

... More
S&F in repairs LED 9/10 Watt tube light fitting mirror intregated type, including LED retrofit tube lamp 9/10 W , LED tube light nominal power 9/10 Watt, L LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, , lumen efficacy of minimum 115 lumens per watt, , integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 2.5 KV, protection grade IP 20, CRI greater than 80%, bema angle of 120 clear, THD below or less than 20%, CW available CCT of 6500K, power factor of minimum 0.95 extruded aluminium LED battens life span of minimum 50000 working hours complete fitting including connecting with PVC insulated multistranded copper flexible cable 1.0 sqmm three core, and PVC round/ square box white colour x 2 Nos for mounting of fitting including taking down old unserviceable complete all as specified & directed. . Note : Make of batten and LED tube lamp should be of same make.

30

-

-

... More
S&F in repairs LED 20 Watt tube light fitting intregated type, including LED retrofit tube lamp 20 W , LED tube light nominal power 20 Watt, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, , lumen efficacy of minimum 110 lumens per watt, , integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 2.5 KV, protection grade IP 20, CRI greater than 80%, bema angle of 120 clear, THD below or less than 20%, CW available CCT of 6500K, power factor of minimum 0.95 life span of minimum 50000 working hours and LED batten with aluminium housing and polycarbonate diffuser complete fitting including connecting with PVC insulated multistranded copper flexible cable 1.0 sqmm three core, and PVC round/ square box white colour x 2 Nos for mounting of fitting complete all as specified & directed. . Note (i) Make of batten and LED tube lamp should be of same make.

410

-

-

... More
Supply & fixing in repair LED light fitting 6 watt surface recessed round polycarbonate housing down lighter with superior light output as per existing size and shape , LED wattage of minimum 3 watt each and Maximum 5 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen efficacy of minimum 110 lumens per watt, isolated electronic LED driver (SMPS based constant current supply) with output short circuit protection, over voltage protection, surge voltage protection upto 2 KVs, protection grade IP 20, CRI greater than 80%, bema angle of 120 clear, ITHD below or less than 15%, CW available CCT of 5700K, power factor of minimum 0.95, CRCA powder coated white after phosphochromate treatment housing, life span of minimum 50000 working hours including making electric connection from source with PVC sheathed copper conductor wire of 1.5 Sqmm x 3 core complete all as specified and directed by EIC.

20

-

-

... More
Taking down existing panel light fitting any type (600 mm x 600 mm) recess mounting/surface and S&F LED light fitting 40/42 watt recess mounting of size 600 mm x 600 mm , , LED wattage of minimum 3 watt each and Maximum 5 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen efficacy of minimum 115 lumens per watt, isolated electronic LED driver (SMPS based constant current supply) with output short circuit protection, over voltage protection, surge voltage protection upto 2 KVs, protection grade IP 20, CRI greater than 80%, bema angle of 120 clear, ITHD below or less than 15%, CW available CCT of 5700K, power factor of minimum 0.95, CRCA powder coated white after phosphochromate treatment housing, life span of minimum 50000 working hours including making electric connection from source with PVC sheathed copper conductor wire of 1.5 Sqmm x 3 core complete all as specified and directed by EIC.

45

-

-

... More
Taking down existing panel light fitting any type (600 mm x 600 mm) recess mounting/surface and S&F LED light fitting 35/36 watt recess mounting of size 600 mm x 600 mm , , LED wattage of minimum 3 watt each and Maximum 5 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen efficacy of minimum 115 lumens per watt, isolated electronic LED driver (SMPS based constant current supply) with output short circuit protection, over voltage protection, surge voltage protection upto 2 KVs, protection grade IP 20, CRI greater than 80%, bema angle of 120 clear, ITHD below or less than 15%, CW available CCT of 5700K, power factor of minimum 0.95, CRCA powder coated white after phosphochromate treatment housing, life span of minimum 50000 working hours including making electric connection from source with PVC sheathed copper conductor wire of 1.5 Sqmm x 3 core complete all as specified and directed by EIC.

40

-

-

... More
Supply and fixed in repair bracket made out of galvanized tube light grade 25mm dia bore (light grade) 1.50 meter long including hot/cold bendig,beldig making hole in GI pipe and band as required,with MS clamps made of 25x3mm GI flat incl,nuts and bolts with one coat of red oxide primer and two coat of sliver paint complete all as specified and directed.

30

-

-

... More
Supply & fixing in repairs sheet metal enclosure for MCB, DB, SPN, 240 Volts, 100 amps rated busbar, 4 way single door enclosure made up of CRCA sheet steel,powder coated, IP 30 IK 08 including fixing the DB box flush in wall of any type and making good the distrubed surface to match as the existing with all as specified and directed by Engr-in-charge

5

-

-

... More
Supply & fixing in repairs sheet metal enclosure for MCB, DB, SPN, 240 Volts, 100 amps rated busbar, 4 way double door enclosure made up of CRCA sheet steel,powder coated, IP 42 including fixing the DB box flush in wall of any type and making good the distrubed surface to match as the existing with all as specified and directed by Engr-in-charge

5

-

-

... More
Supply & fixing in repairs sheet metal enclosure for MCB, DB, SPN, 240 Volts, 100 amps rated busbar, 8 way Double door enclosure made up of CRCA sheet steel,powder coated, IP 43, IK 09 including fixing the DB box flush in wall of any type and making good the distrubed surface to match as the existing with all as specified and directed by Engr-in-charge

10

-

-

... More
Supply & fixing in repairs sheet metal enclosure for MCB, DB, SPN, 240 Volts, 100 amps rated busbar, 12 way Double door enclosure made up of CRCA sheet steel,powder coated, IP 43, IK 09 including fixing the DB box flush in wall of any type and making good the distrubed surface to match as the existing with all as specified and directed by Engr-in-charge

15

-

-

... More
Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning

265

-

-

... More
Supply and fixed in repairs MCB SPN 40 Amps, 'C' curve 10kA, 240 Volts and to be housed in DBs complete including necessry connection all as specified and directed. (Note :- Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating)

60

-

-

... More
Taking down and supply and fixing 4 way double door vertical three phase distribution board with provision for 4 pole MCCB up to 250A as incomer with three phase and single phase (TP/SP) MCB outgoing with complete insulated busbar (tinned electrolytic copper) arrangement, shrouded neutral bar and earth bars, Top and bottom removable gland plates with knockouts IP 43, IK 09 including fixing the DB box flush in wall of any type and making good the distrubed surface to match as the existing with all as specified and directed by Engr-in-charge

16

-

-

... More
S&F MCCB 4 pole, 3 phase, 415 volt of capacity 63 Amp, 16 KA complete with proper copper thimbles, copper reducer etc all as directed.

9

-

-

... More
S&F MCCB 4 pole, 3 phase, 415 volt of capacity 125 Amp, 16 KA complete with proper copper thimbles, copper reducer etc all as directed

7

-

-

... More
Supply and fixng decorative lighting series 2 Light opal globe glass with nickel finish wall lamp E27 LED 7 Watt x 2Lamp with fitting on wall and electric connection all as directed by EIC.Make : JAQUAR CAT PART NO-JNL -NKL-WLBPGG002E27.

23

-

-

... More
Supply and fixng decorative lighting series 1 Light opal globe glass with nickel finish wall lamp E27 LED 7 Watt x 1 Lamp with fitting on wall and electric connection all as directed by EIC.Make : JAQUAR CAT PART NO-JNL -NKL-WLRB0480SE27.

21

-

-

... More
Taking down existing panel light fitting any type (300 mm x 300 mm) recess mounting/surface and S&F LED light fitting 40/42 watt recess mounting of size 600 mm x 600 mm , , LED wattage of minimum 3 watt each and Maximum 5 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen efficacy of minimum 115 lumens per watt, isolated electronic LED driver (SMPS based constant current supply) with output short circuit protection, over voltage protection, surge voltage protection upto 2 KVs, protection grade IP 20, CRI greater than 80%, bema angle of 120 clear, ITHD below or less than 15%, CW available CCT of 5700K, power factor of minimum 0.95, CRCA powder coated white after phosphochromate treatment housing, life span of minimum 50000 working hours including making electric connection from source with PVC sheathed copper conductor wire of 1.5 Sqmm x 3 core complete all as specified and directed by EIC.

50

-

-

... More
Supply and fixing in repairs switch socket combination with Box (02 Hole) Ceramic16 Amps 2 Hole complete all as directed by EIC.

250

-

-

... More
Supply and fixing in repairs modular single phase starter switch 20 Amp 2 module complete all as specified and directed.

35

-

-

... More
Supply and fixing in repairs modular single phase starter switch 25 Amp 2 module complete all as specified and directed.

40

-

-

... More
Supply and fixing in repairs Metal plug 20 Amp 3 pin for AC and geyser complete all as specified and directed.

50

-

-

... More
Supply and fixing in repairs Metal Socket 20 Amp 3 pin for AC and geyser complete all as specified and directed.

35

-

-

... More
Taking down old us PVC Conduit pipe any size & supply and fixing 20 mm conduit pipe ISI marked at existing location all as directed by EIC.Make : Akg gray ,SCH 40 Astral PVC conduct pipes,Primco Plast ,GSN Gold.

300

-

-

... More
Supply and fixing in repairs 25 mm dia rigid non metalic PVC conduit, exclusive of boxes(junction/terminal) but inclusive of all tees, elbows, reducers, bell month tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc

220

-

-

... More
Supply and fixing in repairs PVC casing capping 25 x 12mm dia and not less than 1.2mm thick including all fixing accessories such as tees, bends, elbows, coupler etc complete all as specified and directed.

250

-

-

... More
Taking down and Repair/cheking and fixing only and connecting electric meters up to 25 Amp including cheking nutral phase ,earth wire etc all as directed

19

-

-

... More
Note :-(i) Being maintenance nature of work, the contactors trade man should report to E/M complaint cell daily and take complaint from concren JE E/M and after attending complaint he should give feedback and return the complaint slip to concern JE E/M in the evening at 17.30 Hrs on same day. (ii) Tradesman deployed for work should wear proper uniform with full shirt and full Pant. Colour code will be decided by EIC. (iii) For any minor repair required in wiring or their is any fault in circuit where the item under repair is to be replaced, contractor has to identify and recitified the fault without any extra cost. (iv) Contractor must ensure a stock of 25% of total qty as catered in CA or 25% of balance qty of the item as catered in CA (during currency of contract) at the MES provided store. If the contractor not provided said above recovery shall be made as per Terms and Condition of the contract as specified in particular specification. However no ‘Advance on Account’ against this provision as material laying at site shall be admissible (xi) All T&P required at site for installation of light on Bldg/ hanger or at any location shall be arranged by contractor. Rate quoated above all items here in before inclusive provision as under : (a) Provision and maintenance of all tools, plants, equipment and safety gear required for tradesmen under this contract (b) Provision of communication facilities to supervisor and tradesmen. (c Monitoring and management of complaints report from generation to execution of complaint including pending complaints. (d) Updating status of lodged complaints before change of eight hour shift. (e) Provision of motorized conveyance for deployment to all tradesmen under this contract. (f) Basic inputs to be noted from the complainants will be locality, Building No, Qtr No, Name and Rank of complaint and exact nature of complaint and mobile No/ telephone or based on inputs provided in the complaint cell.

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.