Military Engineer Services Tender
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.
Military Engineer Services - MES Tender
Aerospace and Defence
Eprocure
Opening Date30 Dec 2022
Closing Date3 Feb 2023
Tender Amount₹ 38,87,000
Costs
EMD
₹ 78,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2022_MES_572091_1Bid Award Id
ViewTender No
CWE/136-WE/54 OF 2022-23Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets, complete all as specified and directed.
75
-
-
... More
Dismantling framed timber scantlings 40 sq. cm and over in section, in any position, complete all as specified and directed.
0.5
-
-
... More
Dismantling framed timber scantlings in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section, in any position, complete all as specified and directed.
37
-
-
... More
S&F of Gl frame work (Size of grid 605 x 605mm) for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.55 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre, complete all as specified and directed.
75
-
-
... More
S&F of PVC false ceiling with light weight PVC hollow section panel made of 1mm thick and over all thickness of panel 7 mm thick and 200mm vide strip of colour teak / wood grain / melamine finish , fixed in new false ceiling grid made of Aluminum / G.I / M.S / wooden, complete all as specified and directed.
Note: - New false ceiling grid of aluminium / GI / MS / wooden if provided shall be measured and paid separately.
75
-
-
... More
Taking down cement or cement lime plaster, any description on brick or stone masonry surfaces of walls etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
335
-
-
... More
M&L for 15 mm thick rendering in cement mortar (1:6) on stone masonry surfaces or surfaces other than fair faces of brick work, rendering finished even and smooth (without using extra cement), complete all as specified and directed.
120
-
-
... More
M&L for rendering 20mm thick (two layer, 10mm and 10mm thick) in cement mortar (1:4) with water proofing compound @ 3% by weight of cement in second layer or in the manner specified by the manufacturer and in the proportions indicated on fair faces of brick work or concrete surfaces, finished even and fair (without using extra lime or cement), complete all as specified and directed.
Note: Water proofing compound will be measured and paid separately
180
-
-
... More
Supply only integral water proofing compond, all as specified and as directed.
65
-
-
... More
M&L for 5 mm thick rendering in cement mortar 1:3 on concrete surfaces as on ceiling and finished even and smooth (without using extra lime or cement), complete all as specified and directed.
35
-
-
... More
M&L for preparation on newly plastered / previously untreated surfaces of wall and applying two coats of exterior emulsion paint over one coat of priming coat of alkali-resistant priming paint, complete all as specified and directed.
180
-
-
... More
M&L for scrapping existing treatment on walls & completely removing and applying two coats of exterior emulsion paint over one coat of priming coat of alkali-resistant priming paint including one coat of exterior wall care putty, complete all as specified and directed.
360
-
-
... More
M&L for preparation of new plastered or unplastered surface of wall and applying two coats of distemper oil emulsion(OBD), white or tinted over a coat of alkali resistant priming paint including 3 mm thick layer of wall care putty, complete all as specified and directed.
120
-
-
... More
M&L for scrapping of existing treatment and applying one coat 3mm thick of wall care putty and then applying two coats of distemper oil emulsion(OBD), white or tinted over a coat of alkali resistant priming paint after preparation of wall surfaces, complete all as specified and directed.
530
-
-
... More
M&L for preparation of new plastered or unplastered surfaces of walls and applying three coats of white wash on walls, complete all as specified and directed.
20
-
-
... More
M&L for preparation of old plastered or unplastered surfaces of wall and applying one coat of white wash on walls, complete all as specified and directed.
210
-
-
... More
M&L for preparation of new plastered or unplastered surfaces of ceiling and applying three coats of white wash on ceiling, complete all as specified and directed.
35
-
-
... More
M&L for preparation of old plastered or unplastered surfaces of ceiling and applying one coat of white wash on ceiling, complete all as specified and directed.
230
-
-
... More
M&L for roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. including brushing neat cement slurry with 3.0kg of cement per square metre, complete all as specified and as directed.
190
-
-
... More
M&L for coloured non-skid ceramic tiles 7 to 8 mm thick, premium quality conforming to relevant IS (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed bed or bedding layer of mortar 20 mm thick for laying floor finishes in cement mortar (1:6), complete all as specified and directed.
190
-
-
... More
M&L for non skid ceramic coloured tiles 7 to 8 mm thick, premium quality conforming to relevant IS (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm on vertical surfaces such as dado/skirting, set and jointed in neat cement slurry and pointed in white or coloured cement to match the surfaces of tile over and including 10 mm thick backing coat in cement mortar (1:4), complete all as specified and directed.
28.5
-
-
... More
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified and directed.
50
-
-
... More
M&L for non-skid coloured ceramic tiles 7 to 8mm thick, premium quality conforming to relevant IS (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tiles over and including 15mm thick screed bed in cement motar (1:6), complete all as specified and directed.
20
-
-
... More
M&L for 350x 250x 7 mm/ 450X 350X 7mm thick coloured glazed ceramic tiles fixed as in vertical surface such as risers of steps, skirting, dado etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile over and including 15 mm thick screed bed or bedding layer in cement mortar (1:4) complete all as specified and directed.
32
-
-
... More
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for, complete all as specified and directed.
3.51
-
-
... More
M&L for 50mm thick plain cement concrete(1:2:4), type B-0, (using 12.5mm graded stone aggregate) as in sub-base, sub-floors, floors, pavings, roof treatment etc. and finishing cement concrete surface even and smooth, complete all as specified and directed.
58
-
-
... More
S&F of stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks or galvanised wire staples fixed, complete all as specified and directed.
20
-
-
... More
M&L for 50 mm thick cement concrete (1:3:6), type C-2 (using 40 mm graded crushed stone aggregate) as in plinth protection/path laid to slope of 1 in 12 and finishing cement concrete surface even and smooth without using extra cement with and including all necessary form work to divide the area in panels, finishing exposed edges fair or rounding or chamfering of exposed edges, complete all as specified and directed.
40
-
-
... More
M&L for plain cement concrete (1:3:6), type C-1, (using 20mm graded stone aggregate) as in surface channels and drains including necessary form work, complete all as specified and as directed.
1.3
-
-
... More
Demolition of brickwork or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles, all as specified and as directed.
1.5
-
-
... More
M&L for brick work with sub class 'B' bricks , using old size bricks, straight or curved on plan exc 6 m mean radius built in cement mortar (1:6) complete all as specified and directed.
1.5
-
-
... More
M&L for plain cement concrete (1:3:6), type C-1 (using 20 mm graded crushed stone aggregate) as in bed blocks for grouting hold fasts, coping, filling in pressed steel chowkat or similar work including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed.
0.9
-
-
... More
Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) of any description and in any position not specifically provided for, complete all as specified and as directed.
3
-
-
... More
M&L for reinforced cement concrete (1:1½:3) (nominal mix), type A1 (using 20mm graded crushed stone aggregate) as in Chajjas and the like, complete all as specified and directed.
1.7
-
-
... More
Use & Waste of timber formwork to chajjas, chullah hoods, troughs and similar items including edges rough finished surfaces complete all as specified and directed.
10
-
-
... More
S&F of TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, complete all as specified and directed.
72
-
-
... More
S&F of TMT bars 6mm to 8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, complete all as specified and directed.
38
-
-
... More
Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) of 100/110 mm bore including accessories set in cement mortar and removing rubbish from site, complete all as specified and directed.
108
-
-
... More
S&F of 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls, complete all as specified and directed.
60
-
-
... More
S&F of 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls, complete all as specified and directed.
48
-
-
... More
S&F of 110 mm bore PVC (SWR) bends any radius with access door, complete all as specified and directed.
12
-
-
... More
S&F of 75 mm bore PVC (SWR) bends any radius with access door, complete all as specified and directed.
12
-
-
... More
S&F of 110 mm bore PVC (SWR) junction single, (Single T) equal or unequal with access door including jointing with solvent cement, complete all as specified and directed.
12
-
-
... More
S&F of 75 mm bore PVC (SWR) junction single, (Single T) equal or unequal with access door including jointing with solvent cement, complete all as specified and directed.
8
-
-
... More
S&F of 110 x 75 mm bore PVC (SWR) reducer including jointing with solvent cement, complete all as specified and directed.
3
-
-
... More
S&F of 75 mm bore PVC (SWR) vent cowl including jointing with solvent cement, complete all as specified and directed.
6
-
-
... More
S&F in repairs bevelled edge mirror of selected quality glass, of any size mounting on 6 mm thick AC building board or commercial ply wood and fixed to wooden plugs with chromium plated brass screws and cup washers, with and including aluminium edging around of mirror, complete all as specified and directed.
9
-
-
... More
S&F in repair brass chromium plated shower rose with or without swivel joints 125 mm size , including fixing to steel pipe or union, complete all as specified and directed.
9
-
-
... More
S&F in repair 15 mm bore PVC connection 450 mm long with two brass chromium plated brass nuts and PVC washers, complete all as specified and directed.
36
-
-
... More
S&F of 15mm bore dia pillar taps, cast copper alloy, fancy type with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed, complete all as specified and directed.
9
-
-
... More
S&F in repair 15mm bore dia stop valves, chromium plated, fancy type, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed, complete all as specified and directed.
36
-
-
... More
Taking up or down 15 mm bore old steel tubing and connections, including cleaning for refixing or removal to store or removal unserviceable pipe from site, complete all as specified and directed.
80
-
-
... More
M&L for cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting exceeding 20cm girth on stone walls, complete all as specified and directed.
30
-
-
... More
S&F of 15 mm bore tubes 'medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors, complete all as specified and directed.
75
-
-
... More
Refixing old 15 mm bore steel tubing and connections in new or old position (Walls, ceiling, floors, etc.), complete all as specified and directed
5
-
-
... More
Taking up or down 20 mm bore old steel tubing and connections, including cleaning for refixing or removal to store or removal unserviceable pipe from site, complete all as specified and directed.
30
-
-
... More
S&F of 20 mm bore tubes 'medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors, complete all as specified and directed.
30
-
-
... More
S&F in repair 15mm bore dia bib taps, chromium plated, fancy type with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed, complete all as specified and directed.
36
-
-
... More
S&F in repairs kitchen plate rack made out of stainless steel 0.50 mm thick sheet with partitions and size of rack 800 x 250 x 900 mm with shape and pattern as per sample kept in Sample room of GE 867 EWS, complete all as specified and directed.
9
-
-
... More
Fixing only in repairs sinks kitchen or laboratory with plugs, washers and wastes; including beding in cement mortar on to dwarf walls, or including fixing cantilever brackets and connecting union to waste pipe; upto 0.5 sqm each, complete all as specified and directed.
9
-
-
... More
M&L for 75 mm diameter of outlet PVC (SWR) floor trap, plain with grating including jointing with solvent cement, complete all as specified and directed.
27
-
-
... More
S&F in repairs sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long, complete all as specified and directed.
9
-
-
... More
S&F in repairs Soap dish, CP, fixed to plugs with chromium plated brass screws complete all as specified and directed.
9
-
-
... More
S&F of PVC low level flushing cistern 10 Ltr capacity, valveless syphonic action type complete with inlet, ball valve, float valve, bends brackets, rawl plug, brass screws handle etc complete having BIS description mark with IS-2731 with and including suitable size of MS brackets, plug, screw all as required incl taking down existing high level/low level flushing cistern any type disconnecting pipes and jointing with new one etc, and making good the floors/walls as per existing floor finish/wall finish including 32 mm bore PVC flush pipe and jointing with water closet of any type, complete all as specified and directed.
4
-
-
... More
S&F in repair of vitreous china squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests and 'P' or 'S' trap (excluding flushing cistern and flush pipe) including provision of lime concrete bedding, connection to trap and flushing pipe etc and making good to disturbed surfaces of floor to match with wxisting surface, complete all as specified and directed.
4
-
-
... More
S&F in repair of vitreous cliina wash basin (flat back or angle back type), angle back, size 600x480mm white, excluding taps, waste, chain and plug and porcelain stopper but including brackets including cutting for and pinning in ends of brackets or erecting stand but exclusive of fixing of supply and waste pipe, complete all as specified and directed.
4
-
-
... More
Taking down shutters of any description exc 1 sqm and n exc 2 sqm each and refixing in same opening after resecuring or easing & adjusting, complete all as specified and directed.
18
-
-
... More
Taking down chowkhats or frame not exc 1.50 sqm each with shutter (without taking off shutters from the frame), complete all as specified and directed.
36
-
-
... More
Taking down chowkhats or frames exc 1.5 sq. m but n exc 4 sq. m each with shutters (without taking off shutters from the frame), complete all as specified and directed.
9
-
-
... More
S&F pressed steel frame of size 125 x 60mm for door with one or more rebates including necessary fixing, lugs, hinges,lock ,strike plate, etc complete all as specified and directed.
45
-
-
... More
S&F pressed steel frame of size 105 x 60mm for door with one or more rebates including necessary fixing, lugs, hinges,lock ,strike plate, etc complete all as specified and directed.
45
-
-
... More
S&F of 35 mm thick (batten thickness) second class hard wood, plain, framed panelled shutters (any number of panels), with panels of 12 mm thick timber flat on both sides (feather edged), or of 12mm thick veneered particle board medium density wood particle board with commercial face veneers complete all as specified and directed. (Note :- The dimension of the various components or parts of shutters shall be as specified in clause 8.24 (a) of MES SSR 2009 Part I)
18
-
-
... More
S&F of 35 mm thick (batten thickness) second class hard wood, glazed and Skelton shutters, open rebated and prepared to receive glass, gauge, etc., divided into squares, with plain chamfered or rounded, mitred and rebated sash bars, edges of framing plain, chamfered or rounded with cut mitred beds for securing glass etc, supplied and fitted to chowkhats complete all as specified and directed. (Note :- The dimension of the various components or parts of shutters shall be as specified in clause 8.24 (a) of MES SSR 2009 Part I)
36
-
-
... More
S&F of factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing and as directed.
16
-
-
... More
S&F of solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing and as directed.
50
-
-
... More
S&F of steel window with side hung shutter, including box type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded, complete all as specified and directed.
35
-
-
... More
S&F of steel window with side hung shutter, including box type hinges with steel handle, and steel peg stay, complete without glazing bars, dovetailed or welded, complete all as specified and directed.
35
-
-
... More
S&F steel ventilator with top hung shutter including hinges, steel peg stay, complete complete all as specified and directed.
5
-
-
... More
S&F steel window or ventilator fixed type with glazing bar complete complete all as specified and directed.
3
-
-
... More
M&L for external teak wood lipping, 6 mm thick on exposed surface of prelaminated particle board, block board or veneered particle board fixed with nails, complete all as specified and directed.
105
-
-
... More
M&L in repair for 18/19 mm thick block boards, grade 2 quality, interior grade, commercial type, fixed with screws to timber frame-work, complete all as specified and directed.
60
-
-
... More
S&F in repair of continuous (piano) hinges mild steel bright finish or electro galvanised 30 mm width of flaps (when open), complete all as specified and directed.
45
-
-
... More
S&F of 150 mm long aluminium, anodised, barrel tower bolt, of extruded section and fixed, all as specified and directed.
54
-
-
... More
S&F of 125 mm size aluminium handles, cast type, anodised, all as specified and directed.
36
-
-
... More
S&F of 150 mm size aluminium handles, cast type, anodised, all as specified and directed.
36
-
-
... More
S&F of 300 mm long aluminium alloy, anodised sliding door bolts with haps staple(bolt type), and fixing clips of sheet, cast or extruted sections and fixing bolt and sliding bolts of extruted sections or cast aluminium alloy and fixed, complete all as specified and directed.
27
-
-
... More
S&F of 100 mm size haps and staple, safety type, aluminium anodised with mild steel hinge pin including bolt to hinge plate and fixed with screw, complete all as specified and directed.
18
-
-
... More
S&F in repair stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks or galvanised wire staples fixed, complete all as specified and directed.
20
-
-
... More
Hacking out old broken glass (any thickness, size, quality or description) from metal frame including punching or drilling out old glazing pins/spring clips and providing and fixing new ones, all as specified and directed.
35
-
-
... More
S&F of 3.0mm thick sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane, complete all as specified and directed.
55
-
-
... More
S&F of 4 mm thick figured glass, pin head type and glazing with oil putty in square not exc 0.50 sqm in each pane, complete all as specified and directed.
8
-
-
... More
S&F of mild steel framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165, complete all as specified and directed.
150
-
-
... More
S&F in repairs stainless steel curtain rod (curtain rails) of 25 mm dia with fixing including decorattive knobs and fixiing in pairs of brackets, stops etc., complete all as specified and directed.
110
-
-
... More
M&L for preparation of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed.
80
-
-
... More
M&L for preparation of old steel surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint, complete all as specified and directed.
120
-
-
... More
M&L for preparation of new wood or wood based surfaces of any description over 10 cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and directed.
75
-
-
... More
M&L for preparation of old wood or wood based surfaces of any description over 10 cm width or girth not otherwise described and applying one coat of synthetic enamel paint, complete all as specified and directed.
135
-
-
... More
Taking down, chipping and removing the loose spailt, damaged cement concrete, cement mortar surfaces of RCC columns, beams, walls, chajjas etc and exposing the reinforced cement concrete , wire brushing and cleaning the exposed steel reinforced bar , applying rust remover over the cleaned re - bar surface, wash with clean water for removing all rusts from the old reinforcement bar surfaces, fixing new reinforcement, cut to lenghts, bend to shape required and tying with and including mild steel wire ( annealed ) not less than 0.9mm in dia for stregthen the members as required , applying two coats of epoxy zinc primer on new and old steel surfaces, saturate the substrate with water applying one coat of water , Nitbond SBR ( Latex ) and cement in ratio ( 1:1:3 ) slurry as bond coat after that applying ready mix epoxy repair mortar, 40 mm average thick in any number of coats, to provide at least 30mm thick cover to reinforcement , finished the surfaces even and fair includ ing erecting and dismantling scafolding for carrying out the work complete all as specified and as directed .
23
-
-
... More
Makes of Epoxy Ready made Mortar and Epoxy chemicals:- Sika India Pvt Ltd / Fosroc Chemicals / Mapei Constructions Productsindia Pvt Ltd / Hindcon Chemicals Ltd.
Notes:- (i) New reinforcement will be measured and paid seperately.
(ii) Cost of fixing of new reinforcement by welding / binding with old reinforcement and providing , errecting and dismantling scaffolding shall deemed to be included in quoted ratres.
-
-
-
... More
M&L for expanded metal (weight not exc 4 kg square metre), cut to length, bent to shape required and tying with and including annealed mild steel wire not less than 0.9mm dia or fixing
with galvanised steel staples supplied and fixed complete to wood or steel members, all as specified and directed.
45
-
-
... More
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc., complete all as specified and directed.
219
-
-
... More
Dismantling and taking down unserviceable main switches, DB's including sub main wiring etc. any type / size and making good disturbed surfaces to match with the existing finishes, complete all as specified and as directed.
11
-
-
... More
Material and labour for point wiring with 1.5 Sqmm (nominal area) PVC insulated un-sheathed single core multi stranded copper conductor FRLS cable 1100 volts grade (conforming to IS) drawn through and including rigid non metallic PVC casing and capping of required size (not less than 20mm) conforming to IS 2079-1973, medium grade with all necessary fittings, surface wiring , for one light point or one fan point or one bell point controlled by one switch, with 1.5 Sq mm PVC insulated and unsheathed copper conductor for earth continuity conductor and making good disturbed surfaces to match with the existing surface roof/wall/floor, complete all as specified and directed including testing on completion.
120
-
-
... More
Material and labour for point wiring with 1.5 Sqmm (nominal area) PVC insulated un-sheathed single core multi stranded copper conductor FRLS cable 1100 volts grade (conforming to IS) drawn through and including rigid non metallic PVC casing and capping of required size (not less than 20mm) conforming to IS 2079-1973, medium grade with all necessary fittings, surface wiring , for one bell/ buzzer point controlled by one push button on the same board with other switches or independent, with 1.5 Sq mm PVC insulated and unsheathed copper conductor for earth continuity conductor and making good disturbed surfaces to match with the existing surface roof/wall/floor, complete all as specified and directed including testing on completion.
9
-
-
... More
Material and labour for point wiring with 1.5 Sqmm (nominal area) PVC insulated un-sheathed single core multi stranded copper conductor FRLS cable 1100 volts grade (conforming to IS) drawn through and including rigid non metallic PVC casing and capping of required size (not less than 20mm) conforming to IS 2079-1973, medium grade with all necessary fittings, surface wiring , for one 3 pin socket outlet, 5 Amps on the same board with other switches, with 1.5 Sq mm PVC insulated and unsheathed copper conductor for earth continuity conductor and making good disturbed surfaces to match with the existing surface roof/wall/floor, complete all as specified and directed including testing on completion.
27
-
-
... More
Material and labour for point wiring with 1.5 Sqmm (nominal area) PVC insulated un-sheathed single core multi stranded copper conductor FRLS cable 1100 volts grade (conforming to IS) drawn through and including rigid non metallic PVC casing and capping of required size (not less than 20mm) conforming to IS 2079-1973, medium grade with all necessary fittings, surface wiring , for one 3 pin socket outlet, 5 Amps on independent board, with 1.5 Sq mm PVC insulated and unsheathed copper conductor for earth continuity conductor and making good disturbed surfaces to match with the existing surface roof/wall/floor, complete all as specified and directed including testing on completion.
36
-
-
... More
Material and labour for point wiring with 2.5 Sqmm (nominal area) PVC insulated un-sheathed single core multi stranded copper conductor FRLS cable 1100 volts grade (conforming to IS) drawn through and including rigid non metallic PVC casing and capping of required size (not less than 20mm) conforming to IS 2079-1973, medium grade with all necessary fittings, surface wiring , for one 3 pin socket outlet, 15 Amps on independent board, with 1.5 Sq mm PVC insulated and unsheathed copper conductor for earth continuity conductor and making good disturbed surfaces to match with the existing surface roof/wall/floor, complete all as specified and directed including testing on completion.
36
-
-
... More
Supplied & fixed for 20 amp single pole, 240 Volt, enclosure with a two pin and earth plug and socket complete with one single pole MCB, all as specified and directed.
9
-
-
... More
M&L for ceiling rose, 3 phase/PVC/ polycarbonate, isolated body, three terminal, 240 Volts, all as specified and directed.
39
-
-
... More
M&L for switch piano, flush type single pole, one way 5 Amp, 240 Volts, all as specified and directed.
120
-
-
... More
M&L for switch socket combination 2 in 1, 3 pin, 5 Amps flush type universal, all as specified and directed.
63
-
-
... More
M&L for switch socket combination 2 in 1, 3 pin, 5 and 15 Amps flush type universal, all as specified and directed.
9
-
-
... More
M&L for bell push, flush type, 5/6 amp, 240 Volts, all as specified and directed.
9
-
-
... More
M&L for buzzer, ding dong AC. 230 volts, single pole, all as specified and directed.
9
-
-
... More
S&F in replacement of lamp angle/batten holder Bakelite Pin/Retrofit type, in and including with 10 watt LED Lamp (B22), all as specified and directed.
63
-
-
... More
S&F of LED light fitting 1x9 Watt / 1X10 Watt bulk head luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size, all as specified and directed.
9
-
-
... More
Supply and fixing of LED lights fitting 1x 18W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
33
-
-
... More
Supply and fixing of LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
6
-
-
... More
Supply and fixing of DB's with MCB incomer suitable for triple pole and neutral(TPN), double door (IP-54), 4 Ways, built-in 200 Amps busbar for neutral link complete suitable for 415 Volts, AC, 50 Hz complete all as specified and as directed.
2
-
-
... More
Supply and fixing of 415V 10KA 'B' curve miniature circuit breaker (MCB) of triple pole and neutral(TPN) and current carrying capacity of 40 to 100 AMP in the DB complete with connection testing and commissioning, all all as specified and directed.
2
-
-
... More
Supply and fixing of sheet metal enclosure, double door for MCB DB's, 8 way with 200 amps rated bus bar suitable for 240 Volt, AC, 50Hz, complete all as specified and directed.
9
-
-
... More
Supply and fixing of 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 40 AMP, in the MCB DB complete with connection testing and
commissioning, all as specified and directed.
11
-
-
... More
Supply and fixing of 240V, 10KA 'C' curve miniature circuit breaker (MCB) of single pole & neutral (SPN) and current carrying capacity of 40 to 63 AMP in the MCB DB complete with connection testing and commissioning, all as specified and directed.
9
-
-
... More
Supply and fixing of 240V, 10KA 'C' curve miniature circuit breaker (MCB) of single pole (SP) and current carrying capacity of 5 To 32 AMP in the MCB DB complete with connection testing and commissioning, all as specified and directed.
54
-
-
... More
S&F of sub main wiring with two single core 6.0 Sqmm PVC (FRLS) copper conductor, insulated multistranded unsheathed cable medium grade including PVC casing and capping of required size (not less than 32mm) conforming to IS 2079-1973 with accessories for sub main connection including 6.0 Sqmm PVC (FRLS) insulated multistranded unsheathed copper conductor used as a earth wire to common earth and connection to earth dolly, all as specified and directed. (Note :- Three runs of 6.0 sqmm PVC FRLS copper conductor shall be measured as one unit length)
270
-
-
... More
M&L for making hole in the existing wall/building without distrubing to existing infrastructure for fixing of exhaust fan complete including making good to match with the existing specification complete all as specified and directed.
9
-
-
... More
Supply and fixing / install of new exhaust fans Metal body AC single phase 230V, size of 230MM Sweep with provn of louvers accessories and eletric connection and taling down old exhaust fan, depositing E/M store yard complete all as specified and as directed.
9
-
-
... More
Supply and fixing of electric water heater (Geyser), storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc., all as specified and directed.
9
-
-
... More
Taking down electric KWH meter and keep in safe custody and refixing the same as including necessary electric connection from main to KWH meter and KWH meter to out going distribution board, all as specified and directed.
9
-
-
... More
Material and labour for earthing complete with galvanised steel earth plate electrode 60cm × 60cm× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised iron or steel earth lead wire 4.0mm dia size by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of MES SSR Part-I, connected to earthing test point all as specified or indicated including testing on completion, including necessary excavation and earth work in any type of soil, GI pipe 20mm dia light grade for watering and GI 15mm dia light grade pipe for protection of earth wire etc. upto test point, PCC chamber with PCC cover in cement concrete (1:2:4) type B-1 (using 20mm graded stone aggregate), funnel, wire mesh, charcoal dust, salt etc, connected to DB as indicated, complete all as specified and as directed.
Notes: Contractor should conduct necessary test such as earth continuity, earth resistance test in presence of Engineer-in-Charge.
4
-
-
... More
Supply and laying in replacement XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, 4.0 core, cross-sectional area 16 sq.mm, complete all as specified and directed.
160
-
-
... More
Excavation in trenches/ foundation in soft / loose soil not exceeding 1.50m wide and not exceeding 1.50m deep for laying of LT under ground cable/ pole foundation and getting out including forming bottom surface to required level or slope, complete all as specified and directed.
28.8
-
-
... More
Returning filling in soft / loose soil including spreading, levelling, watering and well ramming in layers not exceeding 25cm, complete all as specified and directed.
16.22
-
-
... More
Removal of surplus excavated soils to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.50m above the starting point, complete all as specified and directed.
12.58
-
-
... More
M&L for sand cushioning to under ground cable in layers of 23cm thick (8 cm before laying the cable and 15 cm thick after laying the cable) in trenches complete all as specified and directed. Note :-Puned layers of 18 cm thick sand shall measured only.
10.37
-
-
... More
Supply and laying of old size sub-class ’B’ bricks (designation 75), laid flat equal to width of bricks, perpendicular to under groung cables over the dry sand cushioning, for cable protection, complete all as specified and directed.
1113
-
-
... More
M&L for 40mm dia steel tubes (light grade) galvanised with all fittings, laid in trenches/wall/pole/road crossing for protection of underground cable/ earth strip, all as specified and directed.
12
-
-
... More
M&L for boring of holes under road, pavement, hard standing by trenchless technology for laying of GI Pipe for LT cable by using necessary machinery including laying of Heavy duty GI pipe of 80 mm dia, complete all as specified and directed.
5
-
-
... More
Note 1:- (Applicable for all parts/items) : The bidders/contractors are advised to read tender document, all drawings & all corrigendum / amendments and general condition of contracts before entry / quoting the rates.
Note 2:-The contract sum shall be arrived at after deducting amount of schedule of credit from the total quoted amount.
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements