Military Engineer Services Tender
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.
Military Engineer Services - MES Tender
Electrical and Electronics
Eprocure
Opening Date16 Jan 2025
Closing Soon12 Feb 2025
Tender Amount₹ 9,35,000
Costs
EMD
₹ 18,700Document Cost
₹ 500Tender Fee
Refer Documents
Summary
Repair/maint Of Split Type Ac, Flameproof Type Ac ,deep Freezers/summer Winter Appliances Water Cooler And Connectected Items Installed At Afs Panagarh Under Ge (af) Panagarh
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_693515_1Tender No
C/8814/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
REPAIR/MAINT OF SPLIT TYPE AC, FLAMEPROOF TYPE AC DEEP FREEZERS/SUMMER WINTER APPLIANCES WATER COOLER AND CONNECTECTED ITEMS INSTALLED AT AFS PANAGARH UNDER GE (AF) PANAGARH
REPAIR/MAINT OF SPLIT TYPE AC, FLAMEPROOF TYPE AC ,DEEP FREEZERS/SUMMER WINTER APPLIANCES WATER COOLER AND CONNECTECTED ITEMS INSTALLED AT AFS PANAGARH UNDER GE (AF) PANAGARH
REPAIR/MAINT OF SPLIT TYPE AC, FLAMEPROOF TYPE AC ,DEEP FREEZERS/SUMMER WINTER APPLIANCES WATER COOLER AND CONNECTECTED ITEMS INSTALLED AT AFS PANAGARH UNDER GE (AF) PANAGARH
BOQ Items
... More
Servicing and maintanance of flame proof split AC 1.5 ton capacity complete unit for routine check up for smooth functioning checking of refrigerant gas, gas leakage, cheking the functioning of compressor, blower motor, all electrical/electronic circuit, functioning of cooling system, cleaning and washing by using vaccum cleaner/ water spray/ mild liquid seal liquid of air filters, cooling coil, condensor coil, blower motor, fan motor etc., complete unit all as directed by Engr-in-Charge. (Note :(i) Spares required will be measured and paid separately (ii) Servicing of flame proof Split AC 1.5 Ton capacity should be done by OEM or authorize channel partner.))
9
-
-
... More
Taking out existing burnt / unserviceable compressor unit from 1.5 ton capacity of window/split type air conditioner and replacing the same with factory built hermetically sealed rotary new compressor sealed unit including necessary accessories and mounting materials, welding, leak testing by charging with CO2/dry nitrogen gas. Evacuating the system and charging of R-22 Refrigerant gas after ensure leak proof condition and testing complete all as directed. (Note - Refrigerant gas in required quantity shall be measured and paid separately under relevant items of Schedule 'A')
8
-
-
... More
All as per item No 5 here-in- before but of capacity 2.0 ton
1
-
-
... More
Taking out existing burnt / unserviceable compressor unit from 1.5 ton capacity of flame proof split type air conditioner and replacing the same with factory built hermetically sealed rotary compressor unit including necessary accessories and mounting materials, welding, leak testing by charging with CO2/ dry nitrogen gas. Evacuating the system and charging of R-22 Refrigerant gas after ensure leak proof condition and testing complete all as directed.
(Note - Refrigerant gas in required quantity shall be measured and paid separately under relevant items of Schedule 'A'.)
1
-
-
... More
Taking Down of existing damaged / burnt blower motor from split/window type AC and supply & fixing of new blower motor with capacitor & mounting materials single phase, 230 Volts 50 Hz suitable for 1.5 ton & 2 ton capacity of window/Split type AC complete all as specified and directed.
10
-
-
... More
Taking Down of existing damaged / burnt blower motor from flame proof split AC and supply & fixing of new blower motor with capacitor & mounting materials single phase, 230 Volts 50 Hz suitable for 1.5 ton & 2 ton capacity of flameproof split type AC complete all as specified and directed.
1
-
-
... More
Taking Down of existing damaged / oudoor fan motor from split / window/flame proof AC (1.5 / 2 Ton capacity) and replace the burnt unserviceable parts, refixing the same after repair and testing its proper function complete all as directed by Engr-in-Charge.
10
-
-
... More
Taking out damaged metallic / PVC fan blade from window/split/flame proof AC 1.5/2 ton and Supply & fix new PVC fan blade of existing size suitable for 1.5/2 ton window/split type AC/flame proof AC complete all as specified and directed.
12
-
-
... More
Taking out the unserviceable running capacitor and supply and fix new running capacitor of 36/45/50 MFD for 1.5/2.0 ton window/split type AC/flame proof AC complete all as specified and directed.
20
-
-
... More
M&L for charging of refrigerant R-22 HydroChloroFluoroCarbon (HCFC) compound having low chlorine content and ozone depletion potential including cost of leak detection, welding, and refitting the same in entire system as required, including replacing defective liquid strainer, capillary tube of various capacities / types of Air Conditioners installed at any height, testing for its satisfactory operation complete all as directed by Engineer-in-Charge.(Note : Original purchase voucher of gas having GST No shall be submit before payment claim duly entered in measurementbook )
15
-
-
... More
All as per above item No. 13 but R-410a (Pentafluoroethane, Difluoromethane) refrigerant.
12
-
-
... More
All as per above item No. 13 but R-32 (difluoromethane) refrigerant.
12
-
-
... More
M&L for taking out unserviceable PCB unit from split/window AC/ flameproof AC of 1.5/2.0 capacity (inverter/ non inverter) and replace the burnt unserviceable electronic parts, refixing the same after repair and testing its proper function complete all as directed by Engr-in-Charge
25
-
-
... More
Taking out unserviceable burnt PCB unit from non inverter split/Window type AC/flame proof AC and supply and fixing of new PCB unit suitable for existing Split/window AC/flame proof AC of 1.5/2.0 Ton capacity complete all as specified and as directed.
10
-
-
... More
Taking out unserviceable burnt duel PCB unit from inverter split AC/flame proof AC and supply and fixing of new PCB unit suitable for existing Split/Flame proof AC of 1.5/2.0 Ton capacity complete all as specified and as directed.
12
-
-
... More
Taking out unserviceable swing motor from split/window AC/flameproof AC indoor unit and supply and fixing new swing motor suitable for 1.5/2.0 Ton split/window AC/ flameproof AC complete all as specified and as directed.
5
-
-
... More
Taking out unserviceable existing cooling coil unit from window/split AC/flame proof AC of 1.5/2.0 ton capacity and supply and fixing of new cooling coil with thermostat complete all as specified and directed.
6
-
-
... More
Taking out unserviceable existing condensing coil unit from window/split AC/flame proof AC of 1.5/2.0 ton capacity and supply and fixing of new condencing coil with thermostat complete all as specified and directed.
6
-
-
... More
M& L for Split AC mild steel powder coated brackets for mounting outdoor unit as per existing size after taking down old damage brackets complete all as specified and directed.
5
-
-
... More
Taking down the exisiting indoor and outdoor unit of Split/window Air Conditioner/flameproof AC from any location / any capacity and refixing the same at new said location complete all as specified and as directed.
(Note : (a) Necessry regrigirant gas,copper pipes with insulaton will be measured and paid separetely.
(b) All the other miscelleneous items required for fixing is deemed to be included in the quoted rate.)
8
-
-
... More
Taking out existing burnt / unserviceable compressor unit from 208 ltrs capacity Refrigerator & replacing the same with factory built hermetically sealed new compressor unit including necessary accessories and mounting material, welding, leak testing by charging dry Nitrogen gas, charging of refrigerant R-134 A after ensuring leak proof condition. Testing complete all as directed by Engineer-in-Charge. (Note: Refrigerant gas shall be measured and paid separately. )
2
-
-
... More
S&F for new thermostatic switch for 208 to 310 capacity refrigerator after taking out defective thermostatic switch complete all as specified and directed..
2
-
-
... More
S&F for new Refrigerator freezer chamber of capacity 208 ltrs to 310 ltrs after taking out defective Refrigerator freezer chamber complete all as specified and directed.
1
-
-
... More
S&F for new starting relay cum over load protector for refrigerator upto 315 ltrs capacity as per existing make and model of the refrigerator after taking out faulty starting relay cum over load protector complete all as specified and directed.
2
-
-
... More
Taking out existing burnt / unserviceable compressor unit from 40/80 ltrs capacity water cooler & replacing the same with suitable factory built hermetically sealed rotary new compressor unit including necessary accessories and maintaining material, welding, leak testing by dry Nitrogen gas and charging R-134A refrigerant gas after ensuring leak proof condition and testing completed all as directed by Engineer-in-Charge.
2
-
-
... More
S&F for new starting relay suitable for water cooler of capacity 40 / 80 ltrs after taking out defective / unserviceable starting relay complete all as specified and directed.
1
-
-
... More
S&F for new running capacitor suitable for water cooler of capacity 40 / 80 ltrs after taking out defective / unserviceable running capacitor complete all as specified and directed.
2
-
-
... More
S&F for new over load protector suitable for water cooler of capacity 40 / 80 ltrs after taking out defective / unserviceable over load protector complete all as specified and directed.
1
-
-
... More
S&F for new thermostatic switch suitable for water cooler of capacity 40 / 80 ltrs after taking out defective / unserviceable thermostatic switch complete all as specified and directed.
1
-
-
... More
S&F for new PVC connection pipe 15 mm dia of 450 mm long suitable for water cooler of capacity 40 / 80 ltrs after taking out unserviceable PVC connection pipe complete all as specified and directed.
1
-
-
... More
Supply and charging of refrigerant R-134A including cost of welding, leak detection and rectification in the entire system with replacement of liquid strainer and capillary tube including testing of water cooler of capacity 40 / 80 ltrs and refrigerator of capacity 208 ltr to 310 ltr including testing for its satisfactory operation complete all as directed by Engineer-in-Charge.(Note : Original purchase voucher of gas having GST No shall be submit before payment claim duly entered in measurementbook )
5
-
-
... More
Taking out of existing damaged / burnt blower motor and supply and fixing of new blower motor, single phase, 230 Volts, 50 Hz suitable for water cooler of capacity 40/80 ltrs including fixing arrangement complete all as directed by Engineer-in-charge. (Note : Necessary fixing material for the same is deemed to be included in the quoted rate.)
2
-
-
... More
S&F for new stabilizer 4 KVA/5 KVA capacity after taking out of existing damaged / burnt voltage stabilizer of 4 KVA/ 5 KVA capacity complete all as directed by Engineer-in-charge. (Note : Original purchase voucher of stabilizer having GST No shall be submit before payment claim duly entered in measurementbook )
7
-
-
... More
S&F for new auto transformer of voltage stabiliser 4 KVA / 5 KVA capacity after taking out defective / burnt auto transformer complete all as specified and directed.
5
-
-
... More
S&F for new PCB complete with components of capacity 4 KVA / 5 KVA Voltage stabilizer after taking out defective PCB (Printed Circuit Board) complete with components complete all as specified and directed.
5
-
-
... More
S&F for new relay for voltage stabiliser upto 5.0 KVA capacity after taking out faulty relay complete all as specified and directed.
5
-
-
... More
S &F for PVC insulated copper cable 3 core 4 Sqmm sheathed after taking down the unserviceable cable complete all as specified and as directed.
50
-
-
... More
S& F for insulating material for Air Conditioner copper pipe of Suction,discharge,liquid line of various sizes. The insulating material shall have low conductivity, strength, Resistance to Fungi such as one that is based on ASTM G21 standard, excellent resistance to ozone and UV including removing the old insulation complete all as specified and as directed.
20
-
-
... More
S &F for 1/2 " copper pipe (12.7mm) copper pipe of 3mm thick wall thickness for any type/capacity of Air Conditioners installed at any height of the building or hanger with necesssary flaring and jointing arrangements including taking down the unserviceable copper pipe complete all as specified and as directed.
25
-
-
... More
S &F for 3/4 " copper pipe (19.05mm) copper pipe of 3mm thick wall thickness for any type/capacity of Air Conditioners installed at any height of the building or hanger with necesssary flaring and jointing arrangements including taking down the unserviceable copper pipe complete all as specified and as directed.
25
-
-
... More
S & F for 5/8 " copper pipe (15.875mm) copper pipe of 3mm thick wall thickness for any type/capacity of Air Conditioners installed at any height of the building or hanger with necesssary flaring and jointing arrangements including taking down the unserviceable copper pipe complete all as specified and as directed.
15
-
-
... More
S & F for 15 mm dia Drain pipe for AC of any capacity after taking down old drain pipe complete all as specified and as directed.
20
-
-
... More
S & F for copper Cappilary tube as per existing AC/Water cooler/Refrigerator after taking down of old/ unserviceable copper capplilary tube complete all as specified and directed.
10
-
-
... More
S &F for Deforst element for refrigeritaor/Deep freezer after taking down of old/ unserviceable deforst element complete all as specified and as directed.
1
-
-
... More
S &F for Dryer/Strainer for refrigeritaor/Deep freezer/ Water cooler after taking down of old unserviceable dryer/stainer complete all as specified and as directed.
1
-
-
... More
S &F for modular plug and socket 25 Amp, 3 Pin 3 Pole having 6 modules having motor starter Modular Type 25 A, MCB mini SPN 25A 3 KA, Socket 25A, suitable for Air-condition supply,240 volts, AC, 50 Hz after taking down of old unserviceable plug and socket complete all as specified and as directed ,
2
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%