Military Engineer Services Tender
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.
Military Engineer Services - MES Tender
Energy, Oil and Gas
Solar Installation and Products
Electrical and Electronics
Eprocure
Opening Date5 Dec 2024
Closing Soon2 Jan 2025
Tender Amount₹ 42,80,000
Costs
EMD
₹ 85,600Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_686568_1Tender No
8701/70/2024-2025/04/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
(D) On Grid Power Conditioning Unit (Inverter) Supply & installation of 415V 3-ph grid connected Inverters which is converted DC energy produce by the solar array to AC energy such that it synchronizes with the existing AC power sources on site. The Inverter shall have inbuilt MPPT (Maximum Power Point Tracker) feature so as to extract maximum power from PV modules & the MPPT units environmental testing should qualify IEC 60068- 2(1,2,14,30) Equivalent BIS standard. (The voltage variation of +/ 15% to 20% & frequency vatiation +/- 5%) Make- Goodwe/Growatt/Solis/ Delta
-
-
-
... More
(E) AC Distribution Board(Qty-1 Nos)
(i) Supply and installation of 415V 32A 3-ph 50Hz AC distribution board control AC power from PCU Inverter & provided by nacessary surge arrestors system with IP65 protection
(ii) Distribution wiring in 1.1Kv single core stranded FR PVC insutlted & unsheathed copper wire in 16 sq mm (Make-Precision) on wall of suitable lenght:- (For AC power supply from Inverter to AC distribution board to Panel).Make of Cable : As per PS Make.
(iii) Supply and laying of 3.5 core 25 sq.mm. alumunium armoured cable of suitable length by saddling as per requirement of site for ACDB to LT Panel) (iv) Supply and laying of 1 core 4 sq.mm. copper cable of suitable length in PVC rigid conduit pipe (Make-Precision or equivalent) by saddling all as directed for Solar Array DC supply connection.
-
-
-
... More
(F) Misc items
(i) Making soldered joints between conductor to conductors and air terminals for 4 SWG GI (Hot dip) wire including supply of jointing material and painting with 2(two) coats of bitumenous paint all as directed.
(ii) UPVC Conduit Pipes 3/4" with Tee, Elbow. Bendovers, Sockets for DC Cabling as per requirement and all as directed and as per requirement at site.
(iii) UPVC Conduit Pipes 25 mm dia bore 1.5 mm wall thickness with Tee, Elbow, Bendovers. Sockets for DC Cabling, as per requirement and all as directed.
(iv) UPVC Conduit Pipes 25 mm dia bore 1.5 mm wall thickness with Tee, Elbow, Sockets, Ball Valves for Manual Module Cleaning System as per requirement and all as directed. Make of UPVC pipe and fittings : Supreme/Prince/Gold Winflow/ Reliance
(v) Supply & fixing of GI (Hot Dipped) strips 25 mm x 3 mm thick horizontal run on the Parapet/Roof Wall with GI Saddles 1100 mmi apart including making good the damages to building works (Galvanised shall be above 75 microns) as per requirement and all as directed.
(vi) Supply & fixing GI (Hot Dipped) strips 25 mm x 3 mm thick for vertical run on wall with GI saddles spaced not exceeding 1000mm apart apart including making good the damages to building works (Galvanised shall be above 75 microns) as per requirement and all as directed.
-
-
-
... More
(vii) Earthing with 1.5 Mts. long Copper bonded Rod galvanized above 250 microns with bolts, double muts, double washers including supply and fixing 15 mm dia bore tube for GI Strip protection ( 1 Mts, long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 2 Mts. below the ground level- Chemical Earthing as per standard as per requirement and all as directed. Qty-2(two) Nos
(viii) Remote Monitoring System-with WiFi as per requirement and all as directed Note 1: Sim card with data back for remote monitoring of system deemed inclusive of the rate.
Note-2: The quoted rate deemed inclusive of the following:-
(i) Transportation charges with Transportation Insurance for the all material of on grid solar system including loading & unloading at site from Co's workshop.
(ii) Insurance for the complete system for the TWO Year, Make: TATA AIG/ United India Insurance Co Ltd./ The New India Assurance.
(iii) AMC- Suraksha which include 24 site Maintenance visits, Response time 2 hrs and turnaround time 48 hrs, Monthly plant performance report to be submitted to department by the contractor.
-
-
-
... More
Note: The quoted rate deemed inclusive of the following:-
(i) Transportation charges with Transportation Insurance for the all material of on grid solar system including loading & unloading at site from Co's workshop.
(ii) Insurance for the complete system for the 1st Year.
(iii) AMC- Suraksha which include 12 site Maintenance visits, Response time 2 hrs and turnaround time 48 hrs, Monthly plant performance report. (iv) Fixing of zero export device (ZED) is inclusive in quoted rate.
(v) Guarantee and warranty of Solar panel and connected devices is submitted to department. (vi) The report of generated unit of solar power on monthly basis submitted to department. (vii) Satisfactorily testing and commissioning report of the complete system is submitted to department.
-
-
-
... More
Design, supply, installation, testing and commissioning of minimum 10 KWp capacity 540/545/535 Wp mono crystalline silicon solar photo voltic modules/array 19 Nos of high efficiency made of mono crystalline silicon solar PV cells with s&f of terminal box on the module should have provision for opening & replacing the cable etc. as per direction of E.I.C. The general features of PV modules as given below :- a) The module shall be made up mono crystalline silicon cells. b)The interconnected cells shall be laminated in vacuum to withstand adverse environmental conditions. c) The module frame is made of corrosion resistant materials, preferably having aluminium anodized finish. d) The minimum clearance between the lower edge of the modules & the developed ground level shall be 300 mm. e) Surge arresting device to be provide at junction box and module shall be provided bypass diode. f) The SPV module must be IEC 61215, IEC 61730 part I & part II, IEC 61701 certified from any of the accredited certifying agencies. g) Each solar PV module must be warranted by manufacturer at least 80% rated power. Note : (i) Design and qty desided as per OEM recommendation, design and layout drawing should be submitted to Department. (ii) All/ any other equipments/ DC cables is deemed to be included in the quoted rate. (iii) All cost of SEB/ CEA registration and approval are deemed to be inclusive of rate quoted. (iv) quoted rate is deemed to be inclusive of provision of ZED and connected accesseries. (v) Quoted rate is deemed to be inclusive of connected items requited towards complete operation of solar plant.Warranty : The solar power plant carries a 05 years warranty against any
manufacturing defect. Solar photovoltaic modules carry a performance warranty against excess or equal to 90% output till 10 years and then 80% up to 25 years. All Warranties shall be executed and shall be the responsibility of Contractor. Note: 1. One year comprehensive maintence will be included.
2. Rate will be included of mounting structure for roof top application and materials should be galvanised.
3
-
-
... More
(B) Module Mounting Structure (MMS) (Qty-19 Nos) Supply & fixing of the anti-corrosive M.S. Hollow square/rectangular /tube Structure on the terrace of the building fixing of PV modules (each structure fixing up I module) by fixing of fastner, nuts & bolt. The structure must be withstand of the wind load of 180 Km/hr. as per IS 875. the minimum clearance of the lowest part of the module structure & the terrace is not less than 300mm & the total load of the structure when installed with PV modules on the terrace should be less than 60 Kg/m2. The array structure shall be grounded properly using maintenance free earthing kit suitable for mounting over building terrace & RCC foundation must be minimum M-25 Grade. Make of MS hallow section -Tata /SAIL equivalent make approved list of E-in-C Br or ADG (P) Channi.
-
-
-
... More
(C) Array Junction Boxes (AJB) (Qty-1 Nos)
Supply & fixing of the junction boxes for controlling the DC power output to the PCU along with surge arrestors & IP-65 protection & IEC62208 made of GRP/FRP Power coated aluminium cast aluminium allay with fully dust. water & vermin arrangement including hinged door with EPDM rubber gasket to prevent water entry or IP65, provided for PV array terminal connecting cables with cable lug including high quality suitable capacity of SPD's or MCB's/MCCB. SPD should use as per Class-11.
-
-
-
... More
(D) On Grid Power Conditioning Unit (Inverter) Supply & installation of 415V 3-ph grid connected Inverters which is converted DC energy produce by the solar array to AC energy such that it synchronizes with the existing AC power sources on site. The Inverter shall have inbuilt MPPT (Maximum Power Point Tracker) feature so as to extract maximum power from PV modules & the MPPT units environmental testing should qualify IEC 60068- 2(1,2,14,30) Equivalent BIS standard. (The voltage variation of +/ 15% to 20% & frequency vatiation +/- 5%) Make- Goodwe/Growatt/Solis/ Delta
-
-
-
... More
(E) AC Distribution Board (Qty-1 Nos)
(i) Supply and installation of 415V 32A 3-ph 50Hz AC distribution board control AC power from PCU Inverter & provided by nacessary surge arrestors system with IP65 protection
(ii) Distribution wiring in 1.1Kv single core stranded FR PVC insutlted & unsheathed copper wire in 16 sq mm (Make-Precision) on wall of suitable lenght:- (For AC power supply from Inverter to AC distribution board to Panel).Make of Cable : As per PS Make.
(iii) Supply and laying of 3.5 core 25 sq.mm. alumunium armoured cable of suitable length by saddling as per requirement of site for ACDB to LT Panel) (iv) Supply and laying of 1 core 4 sq.mm. copper cable of suitable length in PVC rigid conduit pipe (Make-Precision or equivalent) by saddling all as directed for Solar Array DC supply connection.
-
-
-
... More
(F) Misc items
(i) Making soldered joints between conductor to conductors and air terminals for 4 SWG GI (Hot dip) wire including supply of jointing material and painting with 2(two) coats of bitumenous paint all as directed
(ii) UPVC Conduit Pipes 3/4" with Tee, Elbow. Bendovers, Sockets for DC Cabling as per requirement and all as directed and as per requirement at site.
(iii) UPVC Conduit Pipes 25 mm dia bore 1.5 mm wall thickness with Tee, Elbow, Bendovers. Sockets for DC Cabling, as per requirement and all as directed.
(iv) UPVC Conduit Pipes 25 mm dia bore 1.5 mm wall thickness with Tee, Elbow, Sockets, Ball Valves for Manual Module Cleaning System as per requirement and all as directed. Make of UPVC pipe and fittings : Supreme/Prince/Gold Winflow/ Reliance
(v) Supply & fixing of GI (Hot Dipped) strips 25 mm x 3 mm thick horizontal run on the Parapet/Roof Wall with GI Saddles 1100 mmi apart including making good the damages to building works (Galvanised shall be above 75 microns) as per requirement and all as directed.
(vi) Supply & fixing GI (Hot Dipped) strips 25 mm x 3 mm thick for vertical run on wall with GI saddles spaced not exceeding 1000mm apart apart including making good the damages to building works (Galvanised shall be above 75 microns) as per requirement and all as directed.
-
-
-
... More
(vii) Earthing with 1.5 Mts. long Copper bonded Rod galvanized above 250 microns with bolts, double muts, double washers including supply and fixing 15 mm dia bore tube for GI Strip protection ( 1 Mts, long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 2 Mts. below the ground level- Chemical Earthing as per standard as per requirement and all as directed. Qty-2(two) Nos
(viii) Remote Monitoring System-with WiFi as per requirement and all as directed Note 1: Sim card with data back for remote monitoring of system deemed inclusive of the rate.
Note-2: The quoted rate deemed inclusive of the following:-
(i) Transportation charges with Transportation Insurance for the all material of on grid solar system including loading & unloading at site from Co's workshop.
(ii) Insurance for the complete system for the TWO Year, Make: TATA AIG/ United India Insurance Co Ltd./ The New India Assurance.
(iii) AMC- Suraksha which include 24 site Maintenance visits, Response time 2 hrs and turnaround time 48 hrs, Monthly plant performance report to be submitted to department by the contractor.
-
-
-
... More
Note: The quoted rate deemed inclusive of the following:-
(i) Transportation charges with Transportation Insurance for the all material of on grid solar system including loading & unloading at site from Co's workshop.
(ii) Insurance for the complete system for the 1st Year.
(iii) AMC- Suraksha which include 12 site Maintenance visits, Response time 2 hrs and turnaround time 48 hrs, Monthly plant performance report.
(iv) Fixing of zero export device (ZED) is inclusive in quoted rate.
(v) Guarantee and warranty of Solar panel and connected devices is submitted to department. (vi) The report of generated unit of solar power on monthly basis submitted to department. (vii) Satisfactorily testing and commissioning report of the complete system is submitted to department.
-
-
-
... More
M & L PCC (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) for foundation of MS made panel including necessary form work complete complete all as specified and as directed.
2
-
-
... More
Supply & fix 25 mm dia gun metal valve with iron wheel head screwed both ends for iron pipe and fixed including taking down old unserviceable one complete all as specified and as directed.
2
-
-
... More
Supply & fix 20 mm dia gun metal valve with iron wheel head screwed both ends for iron pipe and fixed including taking down old unserviceable one complete all as specified and as directed.
2
-
-
... More
Cutting / drilling the existing GI pipe 50/40/25 mm dia pipe including CI/DI/GI tee, bend, tapper etc all necessary items all as specified and as directed.
3
-
-
... More
Supply & laying 25 mm dia steel water tube medium grade galvanised with all fittings laid in trenches or fixed in wall including taking down old unserviceable one complete all as specified and as directed.
80
-
-
... More
Supply & laying 20 mm dia steel water tube medium grade galvanised with all fittings laid in trenches or fixed in wall including taking down old unserviceable one complete all as specified and as directed.
30
-
-
... More
S & F 20 mm Bib tap standard of PTMT any colour high pressure screwed for iron pipe with all necessary fittings all as specified and as directed.
2
-
-
... More
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16.0 sq mm 4 core
40
-
-
... More
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3½ core
60
-
-
... More
Excavation in trenches, n. exc. 1.5m wide and n. exc. 1.5m in depth; for laying of cable, n. exc 10 sqm on plan and n exc 1.5 m in depth and getting out in soft/loose soil.
16.2
-
-
... More
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm.
4.41
-
-
... More
Removing excavated material n. exc. 50 m and depositing where directed at a level n. exc. 1.5 m above the starting point
11.79
-
-
... More
M&L Dry sand filling as cable cushoining complete. Note - Thickness for sand shall be measured after punning down 23 cm layer.
6.21
-
-
... More
Supplying and laying un-reinforced precast concrete cable cover, class LV, type 1 with peak, size 250mm x 150mm x 40mm along length of cable in trenches after sand cushioning laid for underground cable protection complete all as specified and as directed
400
-
-
... More
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine or manually as per site requirement including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure.
8
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%