Military Engineer Services Tender

Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date10 Dec 2024
Closing Date31 Dec 2024
Tender Amount₹ 45,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
One 3 pin socket outlet 5 Amps on independent board but not below the switch board of light points in the same vertical plane

30

-

-

... More
All as per item No. 2.00 here-in-before but One 3 pin socket outlet 5 Amps on same board

10

-

-

... More
All as per Item No. 53.00 here-in-before but with FRLSH grade, (ISI mark) PVC insulated and unsheathed two run multistranded copper conductor of size 2.5 Sqmm for one power point of 3 pin 15 Amps on independent board including FRLSH grade (ISI mark), PVC insulated, unsheathed one run multi-stranded copper conductor of size 2.5 sqmm green in colour as earth continuity conductor connected to common earth dolly complete all as specified and directed.

10

-

-

... More
Material & Labour for power point wiring complete with 4.00 sq mm FRLSH, PVC insulated multi stranded copper conductor single core cable 1100 volts grade (Red Colour use for Phase & Black Colour use for Neutral),drawn into and including PVC casing- caping (double interlock type) of not less than 25mm width with accessories and fittings such as bends, elbows, tees, crosses, junction box etc, fixed on wall/ceiling with GI saddles, GI screws, rawl plugs etc. controlled by metal clad switch and drawing 4.00 sq. mm copper stranded conductor PVC insulated, unsheated cable as earth continuity conductor, connected to common earth and earth dolly , all as specified and directed by Engineer-in-Charge Note :-(i) Cost of PVC casing & capping, making good disturbed wall surfaces including finishing with cement mortor 1:4, matching with existing colour/paint of surface are deemed to be included in the quoted rate. (ii). Length of point wiring exceeding 10m but not exceeding 15m in length.(iii) "Length per point" in point wiring in the case of power point shall mean the distance between the industrial socket point abd DB along the run of wiring irrespective of the number of wires in the run.

7

-

-

... More
Supply and fixing in repairs switch piano flush type single pole one way 5 Amps.

410

-

-

... More
Material & labour for switch piano flush type single pole one way 5 Amps. (Note : Item to be measured if executed under new point wiring)

75

-

-

... More
Supply and fixing in repairs Switch socket combination 2 in 1, flush type with shutter, 5/6 Amps

200

-

-

... More
Material & labour for Switch socket combination 2 in 1, flush type with shutter, 5/6 Amps. (Note : Item to be measured if executed under new point wiring)

40

-

-

... More
Supply and fixing in repairs Switch socket combined outlet 2 in 1, 3 pin flush type with shutters 5 and 15 Amp multi purpose.

110

-

-

... More
S&F of Switch socket combined outlet 2 in 1, 3 pin flush type with shutters 5 and 15 Amp multi purpose. (Note : Item to be measured if executed under new point wiring)

10

-

-

... More
S&F in repairs ceiling rose, surface bakelite, 65 x 50 mm, three terminals all as specified and as directed.

40

-

-

... More
S&F of ceiling rose, surface bakelite, 65 x 50 mm, three terminals all as specified and as directed. (Note : Item to be measured if executed under new point wiring)

90

-

-

... More
S&F in repair bell push flush type Single pole 5 Amp

15

-

-

... More
S&F of bell push flush type Single pole 5 Amp. (Note : Item to be measured if executed under new point wiring)

5

-

-

... More
S&F in repair bell ding dong type,AC, 230 volts, single pole

20

-

-

... More
S&F of bell ding dong type,AC, 230 volts, single pole (Note : Item to be measured if executed under new point wiring)

5

-

-

... More
Supply and fixing in repairs Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed.

20

-

-

... More
Supply and fixing of Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed. (Note : Item to be measured if executed under new point wiring)

20

-

-

... More
S&F stepped type electronic fan regulator 100 watt flush type on the existing hylem laminated sheet etc as required.complete all as specified and directed by EIC(Note : Item to be measured if executed under new point wiring)

265

-

-

... More
S&F in repair of stepped type electronic fan regulator 100 watt flush type on the existing hylem laminated sheet etc as required complete all as specified and directed by EIC.

105

-

-

... More
Supply & fixing in repair modular switch piano 1 way 6A, 1 Module.

20

-

-

... More
Supply & fixing in repair modular switch piano 1 way 16A, 1 Module

20

-

-

... More
Supply & fixing in repair modular socket 6A/16A 2/3 Pin combined -2 module (shutter type)

20

-

-

... More
Supply & fixing in repair modular bell switch 1 way 6A, 1 Module.

1

-

-

... More
Supply & fixing in repair stepped type Modular electronic fan regulator 2 module , 120 watt flush type ,

4

-

-

... More
Supply & fixing in repair Modular electronic fan regulator 1- module , 100 watt flush type

6

-

-

... More
S&F in repair 3 pin plug top AC-230 v 15 Amp with indicator lamp

10

-

-

... More
S&F in repair LED bulb 9 watt Adore with B22 base, system luminious efficacy not less than 950 lumens, 3 star rating ,surge protection upto 4 KV ,6500 K complete all as specified and directed by EIC. complete all as specified.

73

-

-

... More
S&F of LED bulb 9 watt Adore with B22 base, system luminious efficacy not less than 950 lumens, 3 star rating ,surge protection upto 4 KV ,6500 K complete all as specified and directed by EIC. including taking out old u/s complete all as specified. (Note : Item to be measured if executed under new point wiring)

10

-

-

... More
S&F LED 20 Watt tube light fitting intregated type, including LED retrofit tube lamp 20 W , LED tube light nominal power 20 Watt, LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, bridgelux LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, , lumen efficacy of minimum 110 lumens per watt, , integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 2.5 KV, protection grade IP 20, CRI greater than 80%, bema angle of 120 clear, THD below or less than 20%, CW available CCT of 6500K, power factor of minimum 0.95 life span of minimum 50000 working hours and LED batten with aluminium housing and polycarbonate diffuser complete fitting including connecting with PVC insulated multistranded copper flexible cable 1.0 sqmm three core, and PVC round/ square box white colour x 2 Nos for mounting of fitting complete all as specified & directed. . Note (i) Make of batten and LED tube lamp should be of same make. (ii) Item to be measured if executed under new point wiring

50

-

-

... More
S&F in repairs LED 20 Watt tube light fitting intregated type, including LED retrofit tube lamp 20 W , LED tube light nominal power 20 Watt, LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, bridgelux LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, , lumen efficacy of minimum 110 lumens per watt, , integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 2.5 KV, protection grade IP 20, CRI greater than 80%, bema angle of 120 clear, THD below or less than 20%, CW available CCT of 6500K, power factor of minimum 0.95 life span of minimum 50000 working hours and LED batten with aluminium housing and polycarbonate diffuser complete fitting including connecting with PVC insulated multistranded copper flexible cable 1.0 sqmm three core, and PVC round/ square box white colour x 2 Nos for mounting of fitting complete all as specified & directed. . Note (i) Make of batten and LED tube lamp should be of same make.

601

-

-

... More
S&F in repairs LED 2 X 18 Watt tube light fitting (T8 type) tube light fitting intregated type, including LED retrofit tube lamp 20 W, 2 Nos, LED tube light nominal power 20 Watt, LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, bridgelux LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, , lumen efficacy of minimum 110 lumens per watt, , integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 2.5 KV, protection grade IP 20, CRI greater than 80%, bema angle of 120 clear, THD below or less than 20%, CW available CCT of 6500K, power factor of minimum 0.95 life span of minimum 50000 working hours and LED batten with with powder coated CRCA housing complete with prewired accessories complete fitting including connecting with PVC insulated multistranded copper flexible cable 1.0 sqmm three core, and PVC round/ square box white colour x 2 Nos for mounting of fitting complete all as specified & directed. . Note (i) Make of batten and LED tube lamp should be of same make.

2

-

-

... More
S&F in repair LED tube lamp 20 Watt LED retrofit tube light with aluminium housing and polycarbonate diffuser, double side connection 240 V, LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, bridgelux LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, , lumen efficacy of minimum 110 lumens per watt, , integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 2.5 KV, protection grade IP 20, CRI greater than 80%, bema angle of 120 clear, THD below or less than 20%, CW available CCT of 6500K, power factor of minimum 0.95 life span of minimum 50000 working hours to be fixed in existing batten/ patti including changing the wiring complete all as specified & directed including taking down old unserviceable.

180

-

-

... More
S&F in repair LED tube lamp 20 Watt polycarbonate LED retrofit tube light with high efficacy, single side connection 240 V, LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, bridgelux LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, , lumen efficacy of minimum 110 lumens per watt, , integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 2.5 KV, protection grade IP 20, CRI greater than 80%, bema angle of 120 clear, THD below or less than 20%, CW available CCT of 6500K, power factor of minimum 0.95 life span of minimum 50000 working hours to be fixed in existing batten/ patti including changing the wiring complete all as specified & directed including taking down old unserviceable.

180

-

-

... More
S&F in repairs LED 9/10 Watt tube light fitting mirror intregated type, including LED retrofit tube lamp 9/10 W , LED tube light nominal power 9/10 Watt, LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, Bridgelux LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, , lumen efficacy of minimum 110 lumens per watt, , integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 2.5 KV, protection grade IP 20, CRI greater than 80%, bema angle of 120 clear, THD below or less than 20%, CW available CCT of 6500K, power factor of minimum 0.95 extruded aluminium LED battens life span of minimum 50000 working hours complete fitting including connecting with PVC insulated multistranded copper flexible cable 1.0 sqmm three core, and PVC round/ square box white colour x 2 Nos for mounting of fitting including taking down old unserviceable complete all as specified & directed. . Note : Make of batten and LED tube lamp should be of same make.

170

-

-

... More
S&F LED 9/10 Watt tube light fitting mirror intregated type, including LED retrofit tube lamp 9/10 W , LED tube light nominal power 9/10 Watt, LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, Bridgelux LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, , lumen efficacy of minimum 110 lumens per watt, , integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 2.5 KV, protection grade IP 20, CRI greater than 80%, bema angle of 120 clear, THD below or less than 20%, CW available CCT of 6500K, power factor of minimum 0.95 extruded aluminium LED battens life span of minimum 50000 working hours complete fitting including connecting with PVC insulated multistranded copper flexible cable 1.0 sqmm three core, and PVC round/ square box white colour x 2 Nos for mounting of fitting complete all as specified & directed. . Note : Make of batten and LED tube lamp should be of same make. (ii) Item to be measured if executed under new point wiring

15

-

-

... More
S&F in repair LED lamp 18 Watt 4 Pin type, colour Temp 6500K, retrofit type in existing fitting with necessary change in wiring complete all as specified and directed by EIC

10

-

-

... More
Supply & fixing in repair LED street light 25 watt (Min) 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp, Aluminum die cast housing High efficiency long life LED package in integral module with lumen efficacy of 110 lm/W (Min) and viewing angle of 45 degree to ensure better uniformity, electronic LED driver (SMPS based constant current supply) with Output Short-circuit protection, Surge protection & other reliability test as per latest IS. LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, Bridgelux operational voltage of 170 volts to 270 volts, frequency of 50 Hz, protection grade IP 66, IK-08 CRI greater than or equal to 70% , CW available CCT of 5700K/6500K, power factor of minimum 0.95 , life span of minimum 25000 working hours cincluding necessary electrical connections by PVC sheathed copper conductor wire of 3 core x 1.5 Sqmm and necessary fixing arrangement all as specified. Note : (i) The minimum requirement of lumen efficiency, lumen output and power consumption has been specified. However, as per availability, the bidders may opted higher specification with out any extra cost. The quoted rate is deem to be included for that and no extra payment will be made on this account. (ii) The fittings should be marked 'Date of installation" and "Date of Procurement" with marker pen.

25

-

-

... More
Supply & fixing in repair LED light fitting 1x9W/1X10W bulkhead luminaire having IP65 design with luminium die cast housing and vandal-resistant cover finished in epoxy powder-coated housing including LED light driver holder connecting up with an including three core flexible copper conductor cable of suitable size complete all as specified and as directed

95

-

-

... More
Supply & fixing LED light fitting 1x9W/1X10W bulkhead luminaire having IP65 design with luminium die cast housing and vandal-resistant cover finished in epoxy powder-coated housing including LED light driver holder connecting up with an including three core flexible copper conductor cable of suitable size complete all as specified and as directed. Note : Item to be measured if executed under new point wiring

5

-

-

... More
S&F in repairs Decorative, wall mounting, brushed nickel finish fixture with acrylic diffuser with and including 9 W LED lamp, B22 base complete

70

-

-

... More
Taking down existing panel light fitting any type (600 mm x 600 mm) recess mounting/surface and S&F LED light fitting 36 watt recess mounting of size 600 mm x 600 mm , LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen efficacy of minimum 110 lumens per watt, isolated electronic LED driver (SMPS based constant current supply) with output short circuit protection, over voltage protection, surge voltage protection upto 2 KVs, protection grade IP 20, CRI greater than 80%, bema angle of 120 clear, ITHD below or less than 15%, CW available CCT of 5700K, power factor of minimum 0.95, CRCA powder coated white after phosphochromate treatment housing, life span of minimum 50000 working hours including making electric connection from source with PVC sheathed copper conductor wire of 1.5 Sqmm x 3 core complete all as specified and directed by EIC.

25

-

-

... More
S&F in repairs LED indoor wall light 3 W , goose neck arm, aluminium body operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen efficacy of minimum 150 lumens , protection grade IP 20, CRI greater than 80%

82

-

-

... More
S&F in repair round shape 9/10 watt 220 volts AC Recess-mounting round LED downlighter designed with excellent thermally managed aluminium pressure die-cast housing with heat-dissipating fins , finished in epoxy powder-coated white complete

5

-

-

... More
Taking down unserviceable submain wiring alongwith batten /PVC conduits/Steel conduit/casing caping etc and making good disturbed surfaces of walls/floors and match the existing surface all as directed at site.

300

-

-

... More
Supply and fixing of surface type sub main wiring with two run of 4.00 Sqmm single core PVC FRLS, PVC insulated unsheathed stranded copper conductor (Red/yellow/blue wires for phases and black wire for neutral) drawn in and including drawn into and including PVC casing- caping (double interlock type) of not less than 25mm width with accessories and fittings such as bends, elbows, tees, crosses, junction box etc, fixed on wall/ceiling with GI saddles, GI screws, rawl plugs etc. including one run of 4.00 Sqmm single core PVC FRLS, PVC insulated unsheathed stranded copper conductor as earth wire (green in colour) complete all as specified. Note : (i) Note : 2 runs of line conductor, one run of earth continuity conductor, one run of PVC casing caping shall be measured as unit length. (ii) Cost of PVC casing caping, conductors, making good disturbed wall surfaces including finishing with cement mortor 1:4, matching with existing colour/paint of surface are deemed to be included in the quoted rate.

80

-

-

... More
Supply and fixing of surface type sub main wiring with two run of 6.00 Sqmm single core PVC FRLS, PVC insulated unsheathed stranded copper conductor (Red/yellow/blue wires for phases and black wire for neutral) drawn in and including through PVC casing- caping (double interlock type) of not less than 25mm width with accessories and fittings such as bends, elbows, tees, crosses, junction box etc, fixed on wall/ceiling with GI saddles, GI screws, rawl plugs etc. including one run of 6.00 Sqmm single core PVC FRLS, PVC insulated unsheathed stranded copper conductor as earth wire (green in colour) complete all as specified. Note : (i) Note : 2 runs of line conductor, one run of earth continuity conductor, one run of PVC conduit shall be measured as unit length. (ii) Cost of PVC casing caping, conductors, making good disturbed wall surfaces including finishing with cement mortor 1:4, matching with existing colour/paint of surface are deemed to be included in the quoted rate.

150

-

-

... More
Supply and fixing of surface type sub main wiring with two run of 10.00 Sqmm single core PVC FRLS, PVC insulated unsheathed stranded copper conductor (Red/yellow/blue wires for phases and black wire for neutral) drawn in and including through PVC casing- caping (double interlock type) of not less than 38mm width with accessories and fittings such as bends, elbows, tees, crosses, junction box etc, fixed on wall/ceiling with GI saddles, GI screws, rawl plugs etc.. including one run of 10.00 Sqmm single core PVC FRLS, PVC insulated unsheathed stranded copper conductor as earth wire (green in colour) complete all as specified. Note : (i) Note : 2 runs of line conductor, one run of earth continuity conductor, one run of PVC conduit shall be measured as unit length. (ii) Cost of PVC casing caping, conductors, making good disturbed wall surfaces including finishing with cement mortor 1:4, matching with existing colour/paint of surface are deemed to be included in the quoted rate.

20

-

-

... More
Supply and fixing for surface type sub main wiring with four run of 6.00 Sqmm single core PVC FRLS, PVC insulated unsheathed stranded copper conductor (Red/yellow/blue wires for phases and black wire for neutral) drawn in and including through PVC casing- caping (double interlock type) of not less than 38mm width with accessories and fittings such as bends, elbows, tees, crosses, junction box etc, fixed on wall/ceiling with GI saddles, GI screws, rawl plugs etc. including one run of 6.00 Sqmm single core PVC FRLS, PVC insulated unsheathed stranded copper conductor as earth wire (green in colour) complete all as specified. Note : (i) Note : 4 runs of line conductor, one run of earth continuity conductor, one run of PVC conduit shall be measured as unit length. (ii) Cost of PVC casing caping, conductors, making good disturbed wall surfaces including finishing with cement mortor 1:4, matching with existing colour/paint of surface are deemed to be included in the quoted rate.

20

-

-

... More
Supply and fixing of surface type sub main wiring with four run of 10.00 Sqmm single core PVC FRLS, PVC insulated unsheathed stranded copper conductor (Red/yellow/blue wires for phases and black wire for neutral) drawn in and including through PVC casing- caping (double interlock type) of not less than 38mm width with accessories and fittings such as bends, elbows, tees, crosses, junction box etc, fixed on wall/ceiling with GI saddles, GI screws, rawl plugs etc.. including one run of 10.00 Sqmm single core PVC FRLS, PVC insulated unsheathed stranded copper conductor as earth wire (green in colour) complete all as specified. Note : (i) Note : 2 runs of line conductor, one run of earth continuity conductor, one run of PVC conduit shall be measured as unit length. (ii) Cost of PVC casing caping, conductors, making good disturbed wall surfaces including finishing with cement mortor 1:4, matching with existing colour/paint of surface are deemed to be included in the quoted rate.

30

-

-

... More
S&F in repair PVC casing caping of min 25 mm dia (double interlock type) exclusive of boxes (junction/ terminals) but inclusive of all tees, bends, elobows, reducers, bell mouth tube ends and fixing accessories such as coupler, lock nuts, saddles , pipe hook etc to be fixed on surface for dressing of wiring in neat presentable condition by proper relaying of existing PVC cables including removing of cables/ wires and relaying after fixing of new casing capping including taking down old u/s all as specified and directed.

100

-

-

... More
Supply & fixing in repair Rigid non-metallic PVC conduit(medium) ISI marked of 25 mm dia exclusive of boxes (junction/ terminals) but inclusive of all tees, bends, elobows, reducers, bell mouth tube ends and fixing accessories such as coupler, lock nuts, saddles , pipe hook etc to be fixed on surface for dressing of wiring in neat presentable condition all as specified and directed by Engineer in charge.

20

-

-

... More
M&L for repairing distribution box(DB's) of any rating, any size by proper dressing of wirings,providing lugs, screw, nuts , cleaning of the burned surfaces etc, tightening of all the connections of incoming and outgoings from the MCB's/ DB, connecting Earthing connection to each earth dolly including fixing of DB cover by providing screws etc complete all as specified and directed by EIC.

5

-

-

... More
Taking down unserviceable main switches, DBs / changeover switch alongwith Teak wood boards etc including MCBs/isolators and making good the disturbed surfaces of wall / floors to match the existing surface all as directed at site

16

-

-

... More
Supply & fixing sheet metal enclosure for MCB, DB, TPN, 415 Volts, 100 amps rated busbar, 4 way Double door enclosure made up of CRCA sheet steel,powder coated, IP 43, IK 09 including fixing the DB box flush in wall of any type and making good the distrubed surface to match as the existing with all as specified and directed by Engr-in-charge

5

-

-

... More
Supply & fixing DB Box, in sheet metal enclosure VT DB TPN, MCCB DB TPN 4 way, double door with and including 63 Amp, 16 KA,TP MCCB as incomer and suitable for SP/TP DB in outgoing, enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43, IK 09, As Per IEC 61439-3, with 250 Amp copper bus bar for each phase, with 2 Neutralbar, 2 Earth bar and cable ties for cable management, with fully insulated busbar and shrouded neutral bar, reversible door provision, with colour coded interconnecting wire set, including flushing and fixing DB box in neaty in wall complete all as specified and directed by Engr-in-charge. Note : DB and switchgear shall be of same make.

1

-

-

... More
Supply & fixing sheet metal enclosure for MCB, DB, SPN, 240 Volts, 100 amps rated busbar, 12 way Double door enclosure made up of CRCA sheet steel,powder coated, IP 43, IK 09 including fixing the DB box flush in wall of any type and making good the distrubed surface to match as the existing with all as specified and directed by Engr-in-charge

1

-

-

... More
Supply & fixing sheet metal enclosure for MCB, DB, SPN, 240 Volts, 100 amps rated busbar, 8 way Double door enclosure made up of CRCA sheet steel,powder coated, IP 43, IK 09 including fixing the DB box flush in wall of any type and making good the distrubed surface to match as the existing with all as specified and directed by Engr-in-charge

4

-

-

... More
Supply & fixing sheet metal enclosure for MCB, DB, SPN, 240 Volts, 100 amps rated busbar, 4 way Double door enclosure made up of CRCA sheet steel,powder coated, IP 43, IK 09 including fixing the DB box flush in wall of any type and making good the distrubed surface to match as the existing with all as specified and directed by Engr-in-charge

4

-

-

... More
S & F in repair sheet metal enclosure for MCB, DB, SPN, 240 Volts, 2 way, 2 modules, single door without bus bar, enclosure made up of CRCA sheet steel RAL 9003 powder coated, IP 30 complete all as specified and directed by EIC

1

-

-

... More
Supply & fixing MCB TPN 40-63 Amps, 10 KA 'C' Curve breaking capacity, including connection with suitable size copper lugs complete all as specified and directed by Engr-In-Charge.

25

-

-

... More
Supply & fixing MCB TP 40-63 Amps, 10 KA 'C' Curve breaking capacity, including connection with suitable size copper lugs complete all as specified and directed by Engr-In-Charge.

7

-

-

... More
S&F MCB SP 240 volts 6 to 32 Amps, 10 KA breaking capacity, 'C' Curve including connection with suitable size copper lugs complete all as specified and directed by Engr-In-Charge .

210

-

-

... More
S&F MCB SPN/DP 6 to 32 amps 10 KA , 'C' Curve including connection with suitable size copper lugs complete all as specified and directed by Engr-In-Charge

20

-

-

... More
S & F single pole and neutral enclosure with two pin and earth, plug and socket , suitable for single phase 240 V,complete with one single pole MCB of capacity 20 amps having `C` charactristic, breaking cap 10 KA, including industial plug top, including taking down old u/s complete all as specified and directed by EIC.

7

-

-

... More
S&F in repair metal socket suitable for single phase 240V,IP44 ,20A 2P with Earth, metal body

2

-

-

... More
S&F in repairs laminated hylam sheet cover, ISI marked of Make" Hylam" cut with grooves for mounting of fittings like switches, sockets, fan regulators etc. including fixing with new galvanised screw and cup washer complete all as specified and directed by EIC of following sizes:-

-

-

-

... More
11 x 13 inches

3

-

-

... More
9 x 11 inches

10

-

-

... More
5 x 8 inches

22

-

-

... More
5 x 5 inches

35

-

-

... More
S & F in repairs bracket made out of GI medium grade pipe 1.2 Mtr long of size 32 mm bore bend to shape as per site requirment fixed to pole with 40 x 5 MM -02 Nos, size clamps bolts, Nuts, washers incuding painting two coats of aluminium paint over a coat of primer all as specified and directed.

10

-

-

... More
S&F PVC flexible roll white colour ,size 20 mm dia with all accessories

200

-

-

... More
Attending day to day complaints of Geyser of any capacity any type installed at different buildings inside the airforce area for checking of heating element, thermostat, and all accessories incl electrical connection etc, removing defected parts and re-assembling the same with new parts (new parts will be measured and paid separately under respective item as supply only) and refixing to its existing position including testing for its proper functioning complete all as specified. NOTE : (i) Complaints should attend within 24 hrs after receipt of complaints from Complaint cell . (ii) Sopare parts, if required shall be measured and paid separately under respective items as supply only. (iii) Attended complaints against one particular geyser shall be measured once only during the contract period irrespective of the number of attended /visited for replacement of spares parts or else .

250

-

-

... More
M& L for dismantling Geyser of any capacity any type from exiting position for descaling, removing its accessories removing the scale (white presipated) deposited in it, cleaning the inner tank properly, painting with sparay gun, checking of heating element, thermostat, and all accessories incl electrical connection etc, replacing defected parts with new ones and re-assembling the same (new parts will be measured and paid separately under respective item as supply only) and refixing to its existing position including testing for its proper functioning complete all as specified. NOTE : (i) Sopare parts, if required shall be measured and paid separately under respective items as supply only. (ii) The said job shall be done in MES workshop after dismantling from its original /existing location and transportation charges if required to bring the unit in the MES workshop shall deemed to be included in the unit quoted rate .

40

-

-

... More
Supply only the following items to be incorporate against BOQ Srl No 77.00 and 78.00 only.

-

-

-

... More
Inner container copper suitable for vertical type geyser 50 ltrs storage capacity as per OEMs specifications

5

-

-

... More
Inner container copper suitable for vertical type geyser 25 ltrs storage capacity as per OEMs specifications

10

-

-

... More
Thermostat 0-80 Degree as per exiting size as per OEMs specifications

60

-

-

... More
Supply only Heating element 2 KW, as per OEMs specifications

30

-

-

... More
PVC Connection with steel reinforced pipe for hot water connection of Size 18" x 1/2" including rubber washers

50

-

-

... More
Apperture plate SS suitable for 25/50 ltrs geyser along with rubber gasket, nuts, bolts,etc as per OEMs specifications

40

-

-

... More
Plug top metal body suitable for single phase 240V,IP44 ,20A 2P with Earth

40

-

-

... More
Taking up or down 15/20 mm bore of steel tubing and connections, including cleaning for refixing or removal to store complete all as specified.

100

-

-

... More
Refixing of old steel tubing and connection with new fittings ISI Marked in new or old position (wall, ceiling, floors, etc) of 15 mm bore complete all as specified and as directed.

20

-

-

... More
Supplying & fixing to floor, walls and ceiling 15 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.

40

-

-

... More
Supplying & fixing to floor, walls and ceiling 20 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.

40

-

-

... More
S&F in repairs 15 mm nominal size, nonrising spindle type fancy bib taps as per IS 8931: 1993 made of cast brass including Knob, knob components, divertor & components, nickel-chromium plated finish complete all as specified and as directed.

20

-

-

... More
S&F in repair single phase direct connection type KWH meter , temper proof, plastic body with LCD display, 230/240V, 10-60 Amp, accuracy class I, 50 Hz, Conf to IS 13779, IP 54, with polycarbonate cover ( parameters to show Date, time, current reading, KW, PF) including taking out old u/s complete all as specified Note : Old u/s meter to be deposite in MES store.

10

-

-

... More
S&F in repair three phase, 4 wire direct connection type KWH meter , temper proof, plastic body with LCD display, 230/240V( P-N) and 400/415V (P-P), 10-60Amp, sprint 350, accuracy class I, 50 Hz, Conf to IS 13779, IP 54, with polycarbonate cover( parameters to show Date, time, current reading, KW, PF) in existing position by providing Polycarbonate box cover, including making complete electrical connections, connecting PVC cable by providing suitable size copper lugs etc, complete all as directed specifed . Note : Old u/s meter to be deposite in MES store.

5

-

-

... More
Taking down old ceiling fan/Exhaust fans/Wall mounting fans/ Air cirulators fan of any capacity/sweep after disconnecting the electric supply from any site, checking for its electrical defect and opening fans for checking of mechanical defect after dismantling of fan, carry out repair/over hauling including removing dust and grease, and cleaning of internal mechanical parts of fan with kerosene oil, checking of alignment of shaft, oiling and greasing, checking of worn out bearing and other defective parts, winding, condenser etc and re-assembling, and connecting/refixing of fans in its original position by providing new GI nut bolt, lock washer and lock/split pin complete all as specified and directed by Engr-in-charge. NOTE: (i) Replacement of defective parts will be measured and paid separately under respective item as Supply only., Painting and rewinding, if required shall be measured and paid seperately

650

-

-

... More
Supply only the following items to be incorporate against BOQ Srl No 87.00 only.

-

-

-

... More
Bearing No 6201 Make : SKF/NBC/FAG

300

-

-

... More
Bearing No 6202 Make : SKF/NBC/FAG

300

-

-

... More
Bearing No 6203 Make : SKF/NBC/FAG

10

-

-

... More
Bearing No 6204 Make : SKF/NBC/FAG

10

-

-

... More
Rubber Bush as reqd at site suitable for ceiling fan

19

-

-

... More
Condenser 2.5 mfd Make: Epcos/Tibcon/ Havells

509

-

-

... More
Condenser 4.0 mfd Make: Epcos/Tibcon/ Havells

19

-

-

... More
Lathe work of ceiling Fan shaft any type / size.

100

-

-

... More
Ceilling Fan down rod heavy duty as per existing dia and length of 60 cm including

5

-

-

... More
Aluminium blade assy of celling fan of 1200 mm sweep (set of three)

5

-

-

... More
Canopy (up &down) suitable forcelling fan of 1200/1400 mm sweep

96

-

-

... More
M&L for Opening Stator of Ceiling Fan 1200mm Sweep Cleaning of Parts, replacement of Unserviceable Parts as ordered, Greasing of Moveable Parts, Taking out burnt Coil, Cleaning the Segments complete and Re-winding the Same with Supper Enameled Copper Wire of same Gauge and same Weight with Insulation Paper, Varnishing and Heating, Re-assemble the same after repaired and Testing, complete all as specified and as directed . NOTE : Unserviceable Parts viz Ball Bearing, Bush, Capacitor, Blades, etc. shall be Measured and Paid separately under respective Items as mentioned here-in-before.

580

-

-

... More
M&L for Opening Stator of Ceiling Fan 1400 mm Sweep Cleaning of Parts, replacement of Unserviceable Parts as ordered, Greasing of Moveable Parts, Taking out burnt Coil, Cleaning the Segments complete and Re-winding the Same with Supper Enameled Copper Wire of same Gauge and same Weight with Insulation Paper, Varnishing and Heating, Re-assemble the same after repaired and Testing, complete all as specified and as directed . NOTE : Unserviceable Parts viz Ball Bearing, Bush, Capacitor, Blades, etc. shall be Measured and Paid separately under respective Items as mentioned here-in-before.

50

-

-

... More
M&L for Opening Stator of Exhaust fan of sweep 450 mm any make any model Cleaning of Parts, replacement of Unserviceable Parts as ordered, Greasing of Moveable Parts, Taking out burnt Coil, Cleaning the Segments complete and Re-winding the Same with Supper Enameled Copper Wire of same Gauge and same Weight with Insulation Paper, Varnishing and Heating, Re-assemble the same after repaired and Testing, complete all as specified and as directed . NOTE : Unserviceable Parts viz Ball Bearing, Bush, Capacitor, Blades, etc. shall be Measured and Paid separately under respective Items as mentioned here-in-before.

20

-

-

... More
M&L for Opening Stator of Exhaust fan of sweep 380 mm any make any model Cleaning of Parts, replacement of Unserviceable Parts as ordered, Greasing of Moveable Parts, Taking out burnt Coil, Cleaning the Segments complete and Re-winding the Same with Supper Enameled Copper Wire of same Gauge and same Weight with Insulation Paper, Varnishing and Heating, Re-assemble the same after repaired and Testing, complete all as specified and as directed . NOTE : Unserviceable Parts viz Ball Bearing, Bush, Capacitor, Blades, etc. shall be Measured and Paid separately under respective Items as mentioned here-in-before.

30

-

-

... More
M&L for Opening Stator of Exhaust fan of sweep 300 mm any make any model Cleaning of Parts, replacement of Unserviceable Parts as ordered, Greasing of Moveable Parts, Taking out burnt Coil, Cleaning the Segments complete and Re-winding the Same with Supper Enameled Copper Wire of same Gauge and same Weight with Insulation Paper, Varnishing and Heating, Re-assemble the same after repaired and Testing, complete all as specified and as directed . NOTE : Unserviceable Parts viz Ball Bearing, Bush, Capacitor, Blades, etc. shall be Measured and Paid separately under respective Items as mentioned here-in-before.

80

-

-

... More
M&L for Opening Stator of wall mounted fan 400 mm any make any model Cleaning of Parts, replacement of Unserviceable Parts as ordered, Greasing of Moveable Parts, Taking out burnt Coil, Cleaning the Segments complete and Re-winding the Same with Supper Enameled Copper Wire of same Gauge and same Weight with Insulation Paper, Varnishing and Heating, Re-assemble the same after repaired and Testing, complete all as specified and as directed . NOTE : Unserviceable Parts viz Ball Bearing, Bush, Capacitor, Blades, etc. shall be Measured and Paid separately under respective Items as mentioned here-in-before.

70

-

-

... More
M&L for Opening Stator of Pedestal fan 400 mm any make any model Cleaning of Parts, replacement of Unserviceable Parts as ordered, Greasing of Moveable Parts, Taking out burnt Coil, Cleaning the Segments complete and Re-winding the Same with Supper Enameled Copper Wire of same Gauge and same Weight with Insulation Paper, Varnishing and Heating, Re-assemble the same after repaired and Testing, complete all as specified and as directed . NOTE : Unserviceable Parts viz Ball Bearing, Bush, Capacitor, Blades, etc. shall be Measured and Paid separately under respective Items as mentioned here-in-before.

10

-

-

... More
M&L for Opening Stator of Flame proof Exhaust fan upto 450 mm any make any model Cleaning of Parts, replacement of Unserviceable Parts as ordered, Greasing of Moveable Parts, Taking out burnt Coil, Cleaning the Segments complete and Re-winding the Same with Supper Enameled Copper Wire of same Gauge and same Weight with Insulation Paper, Varnishing and Heating, Re-assemble the same after repaired and Testing, complete all as specified and as directed . NOTE : Unserviceable Parts viz Ball Bearing, Bush, Capacitor, Blades, etc. shall be Measured and Paid separately under respective Items as mentioned here-in-before.

5

-

-

... More
M&L for Opening Stator of Industrial Air circulator fan of any make any model Cleaning of Parts, replacement of Unserviceable Parts as ordered, Greasing of Moveable Parts, Taking out burnt Coil, Cleaning the Segments complete and Re-winding the Same with Supper Enameled Copper Wire of same Gauge and same Weight with Insulation Paper, Varnishing and Heating, Re-assemble the same after repaired and Testing, complete all as specified and as directed . NOTE : Unserviceable Parts viz Ball Bearing, Bush, Capacitor, Blades, etc. shall be Measured and Paid separately under respective Items as mentioned here-in-before.

5

-

-

... More
S&F of Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 including taking down old u/s complete all as specified

5

-

-

... More
M&L for Painting of ceiling fans/Exhaust fans/Pedestal fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc including taking down and refixing on existing position complete as specified and directed by Engr-in-charge.

250

-

-

... More
S&F in repair for round recess mounted LED 12 watt edge lit slim downlight,aluminum housing and PC diffuser, CCT 5700K, Efficacy 100 lm/w

10

-

-

... More
S&F in repair for Round Recess mounted LED panel 18 watt, aluminum housing and PC diffuser , CCT 5700K, Efficacy 100 lm/w

4

-

-

... More
Taking down defective high bay light fittings (any type and any size) from any height,disconnecting, testing all components and Supply & fixing LED high efficency high bay light 200 watt circular light fitting with IP lense for better lightning distribution 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp, Aluminum die cast housing High efficiency long life LED package in integral module with lumen efficacy of 110 lm/W (Min) and viewing angle of 45 degree to ensure better uniformity, electronic LED driver (SMPS based constant current supply) with Output Short-circuit protection, Surge protection & other reliability test as per latest IS. LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, 0 protection grade IP 66, IK-08 CRI greater than or equal to 70% , CW available CCT of 5700K/6500K, power factor of minimum 0.95 , life span of minimum 50000 working hours cincluding necessary electrical connections by PVC sheathed copper conductor wire of 3 core x 1.5 Sqmm and necessary fixing arrangement all as specified. Note : (i) The minimum requirement of lumen efficiency, lumen output and power consumption has been specified. However, as per availability, the bidders may opted higher specification with out any extra cost. The quoted rate is deem to be included for that and no extra payment will be made on this account. (ii) The fittings should be marked 'Date of installation" and "Date of Procurement" with marker pen. (iii) Contractor has to arrange the T&P and ladder required at site for repairing of lights. No T & P will be issued by the Department. Necessary safety rules shall be followed.

22

-

-

... More
S&F PVC insulated multistranded Copper conductor, sheathed round cable ISI marked 2.5 sqmm x 3 core including taking down old u/s complete all as specified

100

-

-

... More
Taking down old unserviceable GI/Copper earth plate from soft and hard soil from any location as directed by Engineer -in- charge.

4

-

-

... More
Material and labour for earthing complete with Galvanised steel earth plate electrode 600x600x6 mm mm buried directly in ground (Earth pit not less than 2.25m below ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to GI wire of size 4 mm as earth lead by means of bolt, nuts, check nuts and washers of galvanised iron or steel, upto 7.5m length, earth wire protected by and including 15 mm dia GI pipe (light grade) and connected to main test point or body of pole/pannel or lightening arrester of main controlling switch as directed including concrete pit in PCC (1:3:6) type C1 , Precast RCC (1:2:4) Type B1 cover slab of size 54x54x5 cm reinforced with 8 mm dia TMT bars @ 100 mm C/C both ways with one handle for lifting made out of 10 mm dia TMT bar embedded in precast cover slab, funnel, wire mesh, 20 mm bore GI Pipe (Medium Grade) for watering, Charcoal and salt in alternate layers of 15 cm (Compacted Thickness) around the earth electrode including necessary excavation, earth work in any type of soil and disposal of spoil to a distance n.exc 50 m and necessary testing complete all as shown in Electrical Plate No 3 of SSR Part-I. NOTE : 1. The unit rare includes for protectionh GI pipe of 15mm and watering pipe of 20mm bore including excavation for earth pit in any type of soil/disintegrate rock. 2. Contractor has to bring agriculture soil from outside of defence land and fill in earth pit to acheive desired result as the soil resisitivity is very high. 3. The cost of GI wire of 4mm including protection pipe, from top of earth plate upto 7.5 meter above/below ground level is deemed to be included in the unit rate. 4. All the joints in GI wire and connectgion with earth plate to be welded through brazing and in addition by providing double brass nut bolt and washer. 5.Costing of welding and nut bolts are deemed to be included in the unit rate

4

-

-

... More
S&F of galvanised steel tubing light grade 15 mm dia for protection of GI wire fixed/ laid on floor/wall fixed with including G I clamps.including taking down old u/s complete all as specified and directed by Engr -in- charge

20

-

-

... More
S&F of earth continuity conductor or main earthing lead of 4 mm GI wire laid in pipe/ fixed to wall on batton or recess or chases or buried in ground or drawn in conduit / pipe or any other indicated situation for loop earthing etc including jointing by using suitable size lugs, GI nuts, bolts and washer including taking down old u/s complete all as specified and directed by Engr- In- charge

20

-

-

... More
S&F in repair Surge protection device Type 1 + 2 to withstand implus current with 10/350 us wave to simulate lightining current. SPD having max contionous operating voltage - 440 Uc (v), I imp in 12.5 KA , I max 50 KA, Pole 3+1 (3 Pole + Neutral), 4 module including installation in parallel connection in DB and making all electrical connections with 4 x 6.0 Sqmm single core copper wire with copper lugs complete all as specified

1

-

-

... More
S&F in repair for round recess mounted LED 3 watt edge lit slim downlight, PC housing diffuser, CCT 6500K, 80 lumens,4 KV surge protection including taking down old u/s complete all as specified

5

-

-

... More
S & F in repair sheet metal enclosure for MCB, DB, VTPN 415 Volts,IP-43, 100 amps rated copper busbar 4 way Double door ( Vertical DB with MCB as incomer) Confirming to IS as per IEC 61439-3 including fixing the DB box flush in wall of any type and making good the distrubed surface to match as the existing complete all as specified

5

-

-

... More
S&F in repair DB Box, in sheet metal enclosure VT DB TPN, MCCB DB TPN 12 way, double door with 200 Amp,25 KA,TP MCCB as incomer (Vertical type double door, Amps, TP, 25 kA MCCB rate inclusive) and suitable for SP/TP DB in outgoing, enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43, IK 09, As Per IEC 61439-3, with 250 Amp copper bus bar for each phase, with Neutralbar, Earth bar and cable ties for cable management, with fully insulated busbar and shrouded neutral bar, reversible door provision, with colour coded interconnecting wire set, including flushing and fixing DB box in neaty in wall complete all as specified

1

-

-

... More
S&F in repair TP MCBs 25 to 32 amps rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) including connection with suitable size copper lugs complete all as specified

2

-

-

... More
S&F for repairing / replacement of old rusted sunken box after removing hylam plate and providing new MS /GI suncken box flush in wall including taking out old unserviceable complete all as specified and directed by EIC including fixing of hylam sheet and making good of surface to match with existing for following size of boxes.

-

-

-

... More
5 x 5 inchs

9

-

-

... More
5 x 8 inchs

5

-

-

... More
11 x 9 inchs

2

-

-

... More
Note :- (i) For item to be replaced under repair (day to day complaint) contactors trade man should report to E/M complaint cell daily and take complaint from concren JE E/M and after attending complaint he should give feedback and return the complaint slip to concern JE E/M in the evening at 17.30 Hrs on same day. (ii) Tradesman deployed for work should wear proper uniform with full shirt and full Pant. Colour code will be decided by EIC. (iii) For any minor repair required in wiring or their is any fault in circuit where the item under repair is to be replaced, contractor has to identify and recitified the fault without any extra cost. (iv) Contractor must ensure a stock of 25% of total qty as catered in CA or 25% of balance qty of the item as catered in CA (during currency of contract) at the MES provided store. If the contractor not provided said above recovery shall be made as per Terms and Condition of the contract as specified in particular specification. However no ‘Advance on Account’ against this provision as material laying at site shall be admissible.

-

-

-

... More
(v) All LED lights/ flood lights shall be properly connected with earth dolly provided with fittings and earth connection. (vi) All LED lights have replacement warranty of 3 years from the date of completion of the contract accordingly condition 46 of GCC (IAFW-2249) shall be amended to extent mention above. Contractor has to submitt warranty certificate from manufacturer . Payment of light fitting will be released after receiving of 3 year replacement warranty certificate (vii) The LED lights will replaced by the contractor free of cost in the case of manufacturing defects and defects covered in standard warranty policy. (viii) The contractor shall submit the surge protection certificate and type test certificate LM 79, LM 80 for luminaries. (ix) All LED fitting shall be identified by printing or fixing sticker duly mentioned the CA number and date of completion. (x) For any change in product or change in catalogue No. etc due to technological up gradation, letter has to be obtained from the lighting company on their letter head signed by an official of National level. (xi) All T&P required at site for installation of light on Bldg/ hanger or at any location shall be arranged by contractor.

-

-

-

... More
Rate quoated above all items here in before inclusive provision as under :Making arrangement for establishment of centralized complaint centre in the existing building as under :- (a) Infrastructure required in Complaint cell i.e. Computer, printer, telephone, furniture, stationary, transport and other necessary items/materials to establish a complaint centre able to receive and manage complaints from the users by all means ie Manual complaint mechanism, Telephonic complaints mechanism, SMS complaint Mechanism and e-mail complaint mechanism, online complaint mechanism and to maintain a consolidated list of complaints and its redressal mode indicating all its relevant data as directed by Engineer-in-Charge.

-

-

-

... More
(b) Provision and maintenance of all tools, plants, equipment and safety gear required for tradesmen under this contract (c) Provision of communication facilities to supervisor and tradesmen. (d) Monitoring and management of complaints report from generation to execution of complaint including pending complaints. (e) Updating status of lodged complaints before change of eight hour shift. (f) Provision of motorized conveyance for deployment to all tradesmen under this contract. (g) Basic inputs to be noted from the complainants will be locality, Building No, Qtr No, Name and Rank of complaint and exact nature of complaint and mobile No/ telephone or based on inputs provided in the complaint redressal sofware. (h) MES may provide software for generation of complaints. However operation entry, printout and releated activities wrt complaint registry and redressal will be the resposibiity of the contractor. On lodging the complaint, the Complaint No will be assigned for reference . Accordingly a corresponding complaint slip shall be generated by the system with all relevant info. Complaint slip should be printed in triplicate and to be handed over immediately to Supervisor who shall detail appropriate tradesmen for repair with required materials/store. One copy of complaint shall be retained in complaint centre and two copies with tradesmen.

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.